05000259/LER-1979-027-03, /03L-0:791010,HPCI Turbine Tripped Due to Failed Rupture Disc on Turbine Exhaust Lines.Caused by Failure of Teflon Sheet on Disc,Providing No Protection to Disc Under Vacuum Condition

From kanterella
(Redirected from ML19210C101)
Jump to navigation Jump to search
/03L-0:791010,HPCI Turbine Tripped Due to Failed Rupture Disc on Turbine Exhaust Lines.Caused by Failure of Teflon Sheet on Disc,Providing No Protection to Disc Under Vacuum Condition
ML19210C101
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 11/07/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19210C100 List:
References
LER-79-027-03L, LER-79-27-3L, NUDOCS 7911130258
Download: ML19210C101 (2)


LER-1979-027, /03L-0:791010,HPCI Turbine Tripped Due to Failed Rupture Disc on Turbine Exhaust Lines.Caused by Failure of Teflon Sheet on Disc,Providing No Protection to Disc Under Vacuum Condition
Event date:
Report date:
2591979027R03 - NRC Website

text

..

NRC FORM 3o6 U. S. NUCLEAR REGULATORY COMMISSION (7-77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) i 6

lAl LIB lRlFl 1 l@l 0 l 0 l - 10 l 0 0 l 0 l 0 l-l 0 l 0 l@l 4 l1 1l1l1l@l l

l@

0 i

8 9 LICENSEE CODE 14 15 LICENSE NUV8ER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T [n"c' I L l@l 0 l 5 l 0 l 0 l 0 l 2 l 5 l 9 @l 1 l 0 l 1 l 0 l 7 l 9 l@l ll ll 0 7l 7l 9 @

O i

7 8

60 61 DOCKET NUMBER 68 69 EVENT DATE 14 75 REPORT DATE 90 EVENT DESCRIPTION AND PROB A8LE CONSEQUENCES h o

2 lWith unit at steady state power of 98 percent, surveillance instruction 4. 5. E.1.d was l ibeing run when high oressure coolant injection turbine tripped due to a failed rupture [

o 3

o a

disc in the turbine exhaust line, rendering HPCI inoperable (Technical Spe:ification l oi>

l3.5.E.1).

There was no danger to the health or safety of the public, no significant l 0 is resulting chain of events, and no previous similar event.

l la1-1I I

ai4 i i I

30 3 3 SYSTEV

CAUSE

C A US E COMP VALVE CODE COCE SU8 CODE COYPONENT CODE SL8 CODE SU8COCE ol>

I Cl J l@ W@ l B l@ l Xl Xl Xl Xl Xl Xl@ l Zl@ l Z @

7 8

9 10 11 12 13 18 sv 20 SECLENTI AL OCCURRENCE REPORT REVISICN

._ EVENT vE AR REPORT NO.

CODE TYPE NO.

@ *j a og l7 l9 l l-l l 0l 2l 7l

]/l 0 l3 lLl l_l l0 l C"

_ 21 42 2J 24 26 27 28 29 30 31 J2 TA E A T ON O PLANT ME H wOURS B IT E FOR d 8.

SL PLlE VAN FACTURER I C l@l x l@

l Z l@

IZ l@

10 l01010 I LyJ@

ly [@

W@

r 11 l0 h l@

'J 34 35 36 3

40 41_

42 4J 44 47 CAUSE DESCRIPTION ANO CORRECTIVE ACTIONS l The Teflon sheet portion of the disc f ailed. providine no orotection to the M Rc tmagvl i

o

3 ; l vacuum condition. The rupture disc was replaced und a DCR issued to purchase an im-I i

proved rupture disc. Fike Metal Prod., 16" U L PLHOV, Teflon /S.S., 181 lbs. at 3780F.

3 I

I i

4 1

7 a 3 80 TA S

% POWER OTHER STATUS iSC O RY OlSCOVERY CESCRiPTf 0N W @ l Ol 91 8l@ l NA l

lB l@l Surveillance Test l

1 5

i!TiviTY CO0 TENT 12 n

44 4s 4s 80 af tE4SE@o OF RELE ASE[Z_]@l AMOUNT OF ACTIVITY LOC ATION OF RELE ASE Zl NA l

NA l

1 6

7 s 9 to 11 44 45 80 PERSONNEL EXPOSURES NUV8ER TYPE CESCRIPTION 0l0l0l@ W @l NA l

i 7

N;u' lies PERSONNEt oESCRiPTiON @

Nuv8ER i

- l0 0 0l@l NA l

7 3 9 11 12 80 LOSS OF OR DAMAGE TO FACILITV

)

7 TYPE D E SCRIP TION NA

- Li l! J y W@l F

4 3 10 80 ISSU E D@[ DESCRIPTION LN_j NA l

lllllllltl llIj LL.l.oj 7

4 J 10 68 69 80 5 o

NAME OF PREPARER PHONE:

S, 7911130 SN

s Tenr:essee Valley Authority Forr. B F-1 i Browns Ferry Nuclear Plant P.c 15..

< 10, is LER SI'PPLEMEN l'AL :NFORMATION Bf RG-bO 259 / 7927 Technical Specification inco!v" '

3.5.E.1 Reported Under Technical Specification T. S. 6.7.2.b.2 Date ot~ Occurrence 10/10/79 Time of Occurrence 1430 1.ait 1

Id enSfication and Description o_f Occurrence:

Rupture disc failed on HPCI exhaust causing trip of HVCI.

Failure occurred during SI with unit on line at 98% power.

Conditions Prior to Occurrence:

Unit was on line at 98% power. SI 4.5.E.1.d was being run.

Unit 2 was at 100% power.

Unit 3 was in a refueling outage.

Action specified in the Technical Specificat:en Surveillt.nce Hequ:rements met

_d u : 'o incperable equipm_ent. Deteribe.

SI's were run on RHR, Core Spray, ADS, RCIC, and Diesel Generator.

A_ ppt en'. Cause of Occurrence:

Teflon sheet failed providing no protection to rupture disc under vacuum condition.

It is believed that a flaw or defect may have been present in the Teflon sheet.

An :!v s:- if Occurrence:

There was no significant resulting chain of events and no danger to health or safety of the public.

Corrective Action

The rupture disc was replaced and a DCR was issued to purchase an improved type rupture disc.

Failura Data:

N/A

  • D.et en tion :

eriod - Lifetime; Responsibility - Adminictrative Supervisor

  • Revisian:

()O 1320 07i