ML19210B986

From kanterella
Jump to navigation Jump to search
Notifies of Completed Review Re Generic Load Definition Methodology & Structural Acceptance Criteria for Mark I Containment long-term Program.Mod to Industry Proposed Load Definition Techniques Needed for plant-unique Analyses
ML19210B986
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 10/15/1979
From: Gammill W, Vollmer R
Office of Nuclear Reactor Regulation
To: Ippolito T, Ziemann D
Office of Nuclear Reactor Regulation
Shared Package
ML19210B970 List:
References
NUDOCS 7911130115
Download: ML19210B986 (2)


Text

'

a pa aseg'o UNITED STATES

+

E j 3 -r,qf(

NUCl. EAR REGULATORY COMMISSION "pl/ / E WASHINGTON. D. C. 20555

  • '@\\.

k.

\\.'.Y./ 8 OCT 151979 MEMORANDUM FOR:

D. Ziemann, Chief, Operating Reactors Branch #3, 00R T. Ippolito, Chief, Operating Reactors Branch #2, DDR FROM:

R. Vollmer, Acting Assistant Director for Systematic Evaluation Program W. Gamill, Acting Assistant Director for Operating Reactor Projects

SUBJECT:

ACCEPTANCE CRITERIA FOR THE MARK I CONTAINMENT LONG TERM PROGRAM The staff has completed its review of the generic load definition methodology and structural acceptance criteria proposed by the Mark I Owners Group in NED0-21888 and NED0 24583, respectively, for the Mark I Containment Long Term Program (LTP). As a result of this review, the staff has determined that certain modifications and/or clarifications to the industry proposed load definition techniques will be necessary to provide LTP plant-unique analyses acceptab'!e to the NRC. These modifications are set forth in the enclosed LTP acceptance criteria, which are attached to a sample transmittal letter.

The enclosed sample letter and acceptance criteria shoulo be transmitted to each licensee of a Mark I/BWR facility within seven days of the date of this memorandum. By copy of this memorancum, DPM is requested to send similar letters to the non-operating Mark I BWR facilities (i.e.,

Fermi Unit 2 and Hope Creek Units 1 and 2). Copies of the acceptance criteria sill be provided separately to the licensing assistants.

Should you have any questions regarding this action, contact C. Grimes or. X-28204.

p hp

. Vollmer, Acting Assistant Director W. Gamill, Acting Assistant Director for Systematic Evaluation Program for Operating Reactor Projects Division of Operating Reactors Division of Operating Reactors cc w/ enclosure:

See page 2 1323 048

// 7 7911130 t

_2_

Enclosure:

As stated cc w/ enclosure:

D. Eisenhut S. Hanauer M. Aycock B. Grimes L. Shao G. Lainas E. Adensam V. Noonan R. Tedesco W. Butler J. Kudrick C. Anderson T. M. Su K. Wichman J. Fair C. Grimes H. Denton T. Carter C. Hofmayer P. Check G. Knighton D. Crutchfield S. Varga J. Stolz R. Baer R. Hartfield D. Thompson F. Schauer J. P. Knight S. Fabic R. Cudlin L. Ruth R. Bosnak F. Schroeder R. Denise S. Sheppard H. Smith 1323 049

.