ML19210B125

From kanterella
Jump to navigation Jump to search
Clarifies 750709 Submittal Re NRC 741227 Order for Mod of License in Areas of Break Spectrum & Partial Loop Operation of Containment Pressure
ML19210B125
Person / Time
Site: Crane 
Issue date: 07/15/1975
From: Arnold R
METROPOLITAN EDISON CO.
To:
US ATOMIC ENERGY COMMISSION (AEC)
References
750705, GQL-1217, NUDOCS 7911040060
Download: ML19210B125 (3)


Text

.

s

~

NRC DISTRIBUTlqN FOR PART 50 DOCKET MATERI AL P

(TEMPORARY FORM) e

~

CONTROL NO:

777h

~

FILE:

F ROM *- Metr p lyan Edis n Co

,DATE OF DOC D ATE REC'D LTR TWX RPT OTHER Reading, 'Pa R C Arnold 7'15-75 T-22-75 XX TO:

Director of Division of t.,R I G CC OTHER SENT URC PDR XXX Reactor Licensing:

1 signed SENT LOCAL PDR XXX CLASS UNCLASS PROPINFO INPUT NO CYS REC'D DOCKET NO:

50-289 XXX 1

DESCRIPTION: Ltr re their submittal of 7 ENCLOSURES:

75 was in error in one area and confusing in another with regards to our 12-27-74 Order for Moq11fication. The section entitled " Break Spectrum and Partial-Loop Operati'on" has not been completed.. Analysis

  • using ECOs final DF R D P

n 9

  • acceptance criteria was not completed at time 1

1 of their submittal, also section entitled iN b

Containment Pressure is n de clear....

PLANT NAME:

Three Mile Island 1 FOR ACTIOTJ/INFORMATION vtm T-23-75 BUTLER (L)

SCHWENCER (L) ZIEMANN (L)

REG AN (E)

W/ Copies W/ Copics W/ Copics W/ Copies STOLZ (L)

DICKER (E) jLEAR (L)

CLARK (L)

W/ Copics W/ Copies W/ Copics W/6Copics PARR (L)

VASSALLO (L)

KNIGHTON (E)

SPI;S W/ Copics W/ Copies W/ Copics W/ Copies YOUNGBLOOD (E) tr:t PsNIEL (L)

PURPLE (L)

W/ Copics W/ Copies W/ Copies W/ Lopies INTERi1AL DISTRIBUTION EG FIM TECH REVIEW DENTON LIC ASST A/T IND N

SCHROEDE R GRIMES R. DIGGS (L)

BRAITMAN f HG FUR GC, ROOM P-SOGA MACCARY GAMMILL H. GEARIN (L)

SALTZMAN GOSSICK/STAF F KNIGHT KASTN E R E. GOULBOURNE (L)

ME LTZ CASE PAWLICKI BALLARD P. KREUTZER (E)

GI AM BUSSO Sil AO SPANG LE R J. LEE (L)

PLANS BOYD

/STELLO M.n C n 005(L)

MCDONALD MOORE (L)

HOUSTON E NVI RO_

S. REED (E)

CHAPMAN DEYOUNG (L)

/ NOVAK(M MULLER M. SERVICE (L)

DUBE (1 tr)

SKOVHOLT (L)

ROSS DICKER

'S. SHEPPARD (L)

/ E. COUE GOLLER (L) (Ltr)

[iPPOLITO KNIGilTON M. SLATER (E)

PETERSON P. CO LLINS TEDESCO YOUNGBLOOD H. SMITH (L)

HARTFIELD (2)

!.COLLIUS REGAN S

KLECKER

/. TEETS (L)

DENISE J

G. WILLI AMS (E)

EISENHUT LAIN AS JECT LDR

['_REGOPR F'lLE & REG!ON (2) /SENAROYA [

VNK~)~

V. WILSON (L)

/' glGGIN O M

111PC YOLLMER fl AR LESS R. INGRAM (L) 1!. DUM01.T (g)

/ mmh EXTERNAL DISTR!OUTION Jel.N'/

4 rn -

n IJVd UJd p.).- LOCAL PDR. Harrisburg, Pa 7 -TIC (ABERNATHY) (1)(2)(10) - N ATIONAL LABS.

1 - PDR SAN /LA'NY 1

1 - NSIC (BUCHANAN) 1 - W. PENNINGTON. Rm E-201 GT 1 -- BROOKIIAVEN NAT LAB 1 - G. ULRIKSON ORNL

!1 - ASLB 1 - CONSU LTANTS 1 - Newton Anderson NEWM ARK /BLUME/AG UACI AN 7 [- ACRS.h MWiSENT g

P

s

/

i a

/

s

/

Mn7M

.l i

T.It'at

/

r

,/

m r, a ma,m

/

METROPOLITAN EDISON COMPANY as:: u,u ce a::.3,w;wucununesacapouncu l

/

POST OFFICE BOX 542 READING, PENNSYLVANI A 19603 TELEPHONE 215 - 929-3601 July 15,1975 GQL 1272 g g r.. % Director [8g 78,w Division of Reactor Licensing i ~; " n # '- % U. S. Nuclear Regulatory Commission \\4 7 Nu Washington, D.C. 2055; %\\,,% %, N N T'

Dear Sir:

g Docket No. 50-289 Operating License No. DPR-50 We have determined that our submittal of July 9,1975, regarding the Commission's December 27, 1974, Order for Modification of License is in error in one area, and may be somewhat confusing in another area. " Break Spectrum and Partial-Loop Operation" In the section of our submittal entitled " Break Spectrum and Partial-Loop Operation" the analysis for partial pump operation referred to has not been completed and the entire paragraph will be superseded by a subsequent submittal. Analysis utilizing ECCS final acceptance criteria was not completed at the time of our July 9,1975, submittal because of the relatively late date (May 1975) that we became aware that such an analysis was required by the NRC staff. The Technical Specifications limits for power versus rod withdrawal for partial pump operation now being utilized are still based on minimum shut-down margin and ejected rod worth criteria. We have been assured by our NSSS vendor representatives that additional, very costly blyses can show that the minimum shutdown margin and ejected rod worth criteria are still limiting, and that the present Technical Specifications limits for power versus rod withdrawal for partial pump operation are still valid. The alternative which we are pursuing with B&W is to show that utilizing very conservative assumptions relative to ECCS criteria that the peak cladding temperatures would be significantly lower for partial pump operation than for four puup operation. Because of the additional conservatism being utilized for this analysis, this alternative approach may result in changes to the present rod withdrawal versus power limits for partial pump operation. Analysis using this alternative for partial pump operation should be completed by July 23, 1975, and will be submitted to you no later than 1 6 7774

+ 6 P August 8,1975, with our proposed Technical Specification change request. Containment Pressure The section of our submittal entitled " Containment Pressure" may be somewhat confusing. In this regard please be informed that: a. analyses have been conducted utilizing TMI-l specific heat sink data b. the results of these analyses show that TMI-l containment pressures are more conservative (i.e. higher) than those derived from the generic ECCS model, and c. a revised Part 5 (Containment Pressure) and revised Attachment 2 for our July 9,1975 submittal will be submitted to you no later than August 8,1975 to further eliminat e any confusion that may still exist in this subject area. Sincerely, t h1 .C. old Vice President RCA:CRS:tas cc: Office of Inspection and Enforcement, Region I File: 20.1.1 / 7.7.3.1.1 i 5m. 237}}