ML19210A178

From kanterella
Jump to navigation Jump to search
Abnormal Occurrence 50-289/75-16:on 750605,variable Low Reactor Coolant Sys Pressure Trip Setpoints Less Conservative than Tech Specs.Specific Cause Not Established. Setpoints Will Be Checked to Assure Proper Calibr
Date released: 08/12/2019 Download: ML19210A178


Nonroutine Rept 75-01 Re Unplanned Radiation Release on 750524.Caused by Pressure Surge in Vent Header from Miscellaneous Waste Evaporator.Second Release Occurred While Attempting to Determine Course of First Release
ML19210A185
Person / Time
Site: Crane 
Issue date: 05/25/1975
From: Herbein J
METROPOLITAN EDISON CO.
To:
References
Download: ML19210A185 (2)
Abnormal Occurrence 75-16:improper Trip Setpoints on Variable Low Reactor Coolant Sys Pressure Sys Violated Tech Specs
ML19210A180
Person / Time
Site: Crane 
Issue date: 06/06/1975
From: Herbein J
METROPOLITAN EDISON CO.
To:
References
Download: ML19210A180 (1)
Abnormal Occurrence 50-289/75-16:on 750605,variable Low Reactor Coolant Sys Pressure Trip Setpoints Less Conservative than Tech Specs.Specific Cause Not Established. Setpoints Will Be Checked to Assure Proper Calibr
ML19210A177
Person / Time
Site: Crane 
Issue date: 06/16/1975
From: Arnold R
METROPOLITAN EDISON CO.
To:
References
Download: ML19210A177 (4)