NHC onu 105 u.s. nucle AR RhGULATOH'

' jA IOG I C,..

OGC,;ET NUMOE R 50-289 i2 70'

' NitC DISTRIGUTION FoR PART 50 DOCKET MATERI AL

]j;yp[y1RErCRT 7

To:R.W. Reid rROM: MetTDpolitan Edison Co.

o^T'I OF OCCUMENT Reading, Pa.

5-14-76 R.C. Arnold =

OATE RECEIVED 5-18-76 C LCTTE R C NOTO RIZ E D PROP sNPUT FORM NUMDER OF COPIES REC 2IVED t

M O R IGIN Al.

$ U NC LASSIFIE D CCCPY

}

I l OESCRIPTION ENCLOSU RE itr. re. their 4-30-76 ltr...

$dvisingthattheseismicqualifacationofvalves C-V2, IC-V3, IC-V4, Nad IC-V6 are not reportable D@nD D

n U(a 1 Signed Cy. Received) b S

PLANT nam :

Three Mile Islend # 1 NOTE:

IF F22SO:3 L E:TCSURE IS INVOLVED SEND DIRECTLY TO K". EGO'1/J. COLLINS j

St.FST?

FOR ACTION /INFORMArlON d.i'l '.3 SAB 5-19-76 I IERANCH CHIEF:

Reid i*:/3 CYS FOR ACTION l

l LIC. ASST:

Ingram l

l 1 w/ CYs I IACaS 10 CYS AMMM/r.NT To LA I

i l

lNTERNAL O!STRISUTION IMfr_LIllE J i

i NRC na i

I &__ E (2) 8

! ',i!?t' ( 3 '-

I

! SCZ10~: DER /IPPCLITO i

i 17?STO' l lNO71K/CFECK s G3IMES/307,7ENCER 1Fach I

' C132 I

i NYYYYYYY1ME I !!ANALTR i i T"DESCO/MCCARY l ZTSWJfr i

! IBAER i !SHA0 i 6totugn/Br':cn i xuC3n/J. Cot _IJNs i

i I

l_

EXTERNAL DISTRIBUTION i

COT:TR OL NU>'.'BER i :LPDR: Harrisburg. PA.

i

i nC 1490 022 EBsIC 1

5017 l

gU

.........4...a

L'flad qmg

$w=:,.;

=

-,,- -,u METROPOLITAN EDISON COMPANY..

- := :r %. : _..

r a :.:

POST OFFICE BOX 542 READING. PENNSYLVANI A 19603 TELEPHONE 215 - 929-3601 May 1h, 1976

__-r-GQL OT2h Q

z bu,f c,,

~~_t

'm Director of Nuclear Reactor Regulations L.s, 3,.

Attentien R. W. Reid, Chief

\\E -

c52fy n,"

U. S. Nuclear Pegulatory Cortission

[,\\

^ ~' :*41' '

N')7 hashington, D.C.

20555 g\\ L Mr. J. P. O'Reilly Office of Inspecticn & Enforcement, Region I U.S. Nuclear Regulatory Cc==ission 631 Park Avenue King of Prussia, PA 19h06

Dear Sirs:

Three Mile Island Nuclear Station Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Event Report 76-15/990 As reported by our letter GQL 0647 of April 30, 1976, we were unable to find documentation supporting the seismic qualification of valves IC-V2, IC-V3, IC-Vh and IC-V6.

Further invastigation with the manufacturers has revealed that each of the above valves are qualified seismic class 1.

This situati:n, therefore was not reportable.

Sincere 1;r, R. C. Arnold Vice President RCA:JJM:ilm File: 61.0008.0010.0003.01 1490 023 SUli