g n:,6g
/
o UNITED STATES 8
k NUCLEAR REGULATORY COMMISSION
'5 3
REGION IV o
611 RYAN PLAZA DRIVE, SUITE 1000
' %I#
1 AUG 1979 Docket No.
99900370/79-01 Airesearch
- nufacturlng Company of Arizona A Divisi:2 cf The Garrett Corporation Atta: M. E. Mitchel Quality Assurance Manager
~
111 Touth 34th Street Phoenix, Arizona 85010 Gentlemen:
This refers to the QA Program inspection conducted by Mr. Wm. D. Kelley, of this office on July 18-19, 1979, of your facility at Phoenix, Arizona, associated with the manufacture of ASME Section III "N" Class 1, 2 & 3 valves and to the discussion of our findings with Mr. J. E. Scott and other members of the staff at the conclusion of the inspection.
This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort is not designed to assure that unique,
implemented; nor to a' quality requirements imposed by a customer are being ssure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others. You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findir.gs.
Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel; and observations by the inspector.
Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.
In accordance with Section 2.790 of the Commission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter together with the enc 1csed inspection report will be placed in the Commission's Public Document Room.
If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty 1177 113 7910180cO/
Aire, search Manufacturing Company of Aricona (30) days to this office to withhold such information from public disclosure.
Any such application must include a full statement of the reasons on the baals of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Do-~~ ant Room.
Should you have any questions concerning this inspection, we will be pleased to discuss then with you.
Sincerely,
__1
=
k f A(1-('%-
i Uldis Potapovs, Chie; Vendor Inspection Brhnch
Enclosure:
Inspection Report No.
99900370/79-01 ll,~
l177 114 2
la
- .g