4 TENNESSEE VALLEY AUTHORITY CH ATTANOOG A. TENNESSEE 37401 400 Chestnut Street Tower II October 4, 1979 Mr. James O'Hailly, Director Office of In ection and Enforcement U.S. Nuclear gulatory CommiJaion Q!
l}l Region II - Sui 3100 101 Marietta Str t
'[
gl"'
Atlanta, Georgia 0303
Dear Mr. O'Reilly:
SEQUOYAH NUCLEAR PLAN"? UNITS 1 AND 2 - DIESEL GENERATOR TURBOCHARGER LUBRICATION - NCR MEB 79 FINAL REPORT The subject deficiency was initially reported to NRC-OIE Inspector W. T. Cottle on June 21, 1979, in accordance with 10 CFR 50.55(e).
An interim report was submitted cn July 20, 1979. Enclosed is our final report.
An identical nonconformance was reported for Watts Bar Nuclear Plant as NCR MES 79-27.
If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.
Very truly yours, TENNESSEM VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure cc: Mr. Victor Stallo, Jr., Director (Ec. closure)
Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission 5
]c30 Washington, DC 20555 g
791015055 7 An Equal Opportunity Employer