ML19209C377

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Needed to Complete Review of Util Submittal for License Amends to Expand Spent Fuel Storage Capacity
ML19209C377
Person / Time
Site: Calvert Cliffs  
Issue date: 08/16/1979
From: Lainas G
Office of Nuclear Reactor Regulation
To: Reid R
Office of Nuclear Reactor Regulation
References
NUDOCS 7910150195
Download: ML19209C377 (3)


Text

M 2

v

$.}

~

DISTRICUTION

-befftral files

.l.

NRC PDR PSB Reading g16 p d 20NLl/

f!EMORANDU'i FOR:

R. Reid, Chief, Operating Reactors Branch #4, D0R FR0ft:

G. Lainas, Chief, Plant Systens Branch, D0R

SUBJECT:

REQUEST FOR ADDITIONAL INFOR"ATION: FUEL P00L CAPACITf EXPANSION (TAC 11930 AND 11931)

Plant Name: Calvert Cliffs Nuclear Power Plant Docket Nos.:

50-317 and 50-318 Responsible Branch: ORB!4 Project Manager:

M. Conner We have reviewed the Baltimore Gas and Electric Company's submittal for license amendments to expand the spent fuel storage capacity at i

the Calvert Cliffs Nuclear Power Plant. We find we need the additional information requested in the attachment to this memorandum in order to complete our review.

i fj O [ g ([ '0 G. Lainas, Chief Plant Systens Branch l

Division of Operating Reactors i

l

Enclosure:

As stated

Contact:

l E. Lantz l

X-27110kb i cc w/ enclosure: i See next page i i I910150Iq5 n I .PSB ,,,(- B: DOR DOR . ~. - i EL,,, dn, ,_EA e,,am ,,,,, Gg /79 lh,(6g,,,,gg as 8/MZ.9 8/.l.W.?9. 87h .L .m

.. AUG 161979 cc w/ enclosure: D. Eisenhut B. Grimes W. Gammill G. Lainas MIPC T. Telford W. Russell G. Knighton E. Adensam M. Conner E. Lantz D. Fieno W. Brooks 1146 226

ENCLOSURE s, REQUEST FOR ADDITIONAL INFORMATION , SPENT FUEL POOL CAPACITY EXPANSION CALVERT CLIFFS NUCLEAR POWER PLANT The amount of boron that you are proposing to put in the plates in the proposed racks does not appear to be sufficient to keep the keff in the proposed racks at or below 0.95 for a fuel assembly loading limit of 48.5 grams of uranium-235 per axial centimeter of fuel assembly. In view of this please provide the following additional infonnation: 1. Provide the change in your calculated keff for the proposed storage lattice when the fuel assembly loading is changed from 48.5 to 43.8 grams of uranium-235 per axial centimeter of fuel assembly. 2. Provide a description of the calculations you made'for the above change in fuel loading and also the one for the keff of the minimum lattice pitch (i.e., 9.625"). Include a statement 6n whether or not you generated a neutron energy spctrum for each of the above cases to get accurate, effective, neutron reaction cross. sections for every case. 3. Since it is our understanding that the 16 group Hansen-Roach cross section set was developed for fast spectrum reactors, provide justification and verification of its use in a primarily thermal neutron energy spectrum. 4. Provide a proof that the effective boron region cross sections you used in the KENO-IV verification calculation are accurate. 5. Provide a copy of NES 81A0567, " Nuclear Design Analysis Report for the Calvert Cliffs Unit #1 Nuclear Plant High Density Spent Fuel Storage Racks," dated March 1979, which is referenced in your submittal. 6. The NRC requires verification that the amount of boron used for the calculations is actually in all of the storage containers which are put into the spent fuel pool. Part of this required verification is an on-site neutron attenuation test for missing places. Provide a description of the way you will verify that the amount of boron you used in your calculations is actually in the storage containers. Include a description of the on-site neutron attentuation test that you will perfonn. 7. The NRC requires the licensee to have a method to verify that the amount of boron used for the calculations remains in the plates throughout the life of the racks. Provide a description of this verification method. t e 1146 227}}