Text
~
TENNESSEE VALLEY AUTHORITY CH ATTANOOGA, TENN ESSEE 37401 400 Chestnut Street Tower II September 26, 1979 Mr. James P.
'Reilly, Director Office of Inspe tion and Enforcement U.S. Nuclear Beg atory Commission Region II - Suite 100 101 Marietta Stree Atlanta, Georgia 3 03
Dear Mr. O'Reilly:
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - DIESEL GENT.RATOR FIELD RELAY COIL (K1) FAILURLS - NCR 15P - FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-01E Inspector W. T. Cottle on August 27, 1979, in accordance with 10 CFR 50.55(e).
Enclosed is our first interim report. We expect to submit our next report before fuel loading in unit 1.
If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.
Very truly yours.
TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure Mr.VictorStallo,Jr., Director (Enclosure)/
cc:
Office of Inspection and Enforcement U.S. Nealear Regulatory Commission Washington, DC 20555 1090 243
\\
An Equal Occortunity Empicyer Qjf 3
7910040 T7