Responds to IE Bulletin 79-07.Lists Organizations Responsible for Programs Used in Verification of Computer Programs That May Have Been Used in Seismic Stress Analysis of safety-related Piping
ML19209A333
Person / Time
Site: Rancho Seco
Issue date: 06/21/1979
From: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
NUDOCS 7910030616
Download: ML19209A333 (1)


Text

T~/ &

' i SaEG

~

SACRAMENTO MUf4ICIPAL UTILITY DISTRICT O 6201 S street. Box 15830, Sacramento. California 95813; (916) 452-3211 June 21,1979 d ' l1.,.

q<h

.~ -

s9 Nuclear Regulatory Commission O,

'Dg d Attention:

Mr. R.H. Engelken, Director l; F,,'

' r. J/

Region V Office of Inspection y

a -Q.. g?' /'$

and Enforcement G...

/

1990 florth California Boulevard v ' ' r f.ifn Walnut Creek Plaza, Suite 202

'.lalnut Creek, California 94596 Docket No. 50-312 Rancho Seco Nuclear Generating Station, Unit No. 1

Dear Mr. Engelken:

The reply to NRC Bulletin No. 79-07, dated April 14, 1979, entitled " Seismic Stress Analysis of Safety-Related Piping", provided a listing of computer programs utilized by the Los Angeles Power Division of Bechtel Power Corporation for the subject analysis.

As a supplement to item 3 (three) of the reply, the following provides the organizations res-ponsible for programs used in the verification of the programs that may have been used in the analysis:

(a) ADLPIPE -- Arthur D. Little, Inc.

(b) ME 101 -- Bechtel Power Corporation (c) ME 632 -- Bechtel Power Corporation (d) NUPIPE -- Nuclear Services Corporation (e) PISOL -- EDS Nuclear Inc.

(f) PIPESD -- URS / John A. Blume & Associates (g) SUPERPIPE -- EDS Nuclear Inc.

(h) TPIPE -- PMB Structural Engineers Sincerely yours, 0

u,.I

/

d ohn 4 Mattimoe Assistant General Manager and Chief Engineer 1036 L'O 1910080 g g g

t

,