ML19208D467

From kanterella
Jump to navigation Jump to search
Forwards LERs 79-015/99X-0 & 79-016/03L-0
Date released: 08/10/2019 Download: ML19208D467


LER 79-016/03L-0:on 790827,diesel Generator 2 Tripped on Low Oil Pressure,Rendering Generator Inoperable.Caused by Leak Allowing Water to Enter Oil Sys,Causing High Crankcase Pressure.Oil Cooler Replaced
ML19208D479
Person / Time
Site: Arkansas Nuclear 
Issue date: 09/14/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208D479 (1)
LER 79-015/99X-0:on 790817,as Result of Analysis of Seismic Category I Pipe supports,37 Restraints Were Identified to Have Safety Factor of Less than Two.Supports Modified
ML19208D472
Person / Time
Site: Arkansas Nuclear 
Issue date: 09/14/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208D472 (1)
Forwards LERs 79-015/99X-0 & 79-016/03L-0
ML19208D466
Person / Time
Site: Arkansas Nuclear 
Issue date: 09/14/1979
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19208D466 (1)