ML19208C178
| ML19208C178 | |
| Person / Time | |
|---|---|
| Issue date: | 08/10/1979 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | DEEPSEA VENTURES, INC. |
| References | |
| NUDOCS 7909250087 | |
| Download: ML19208C178 (1) | |
Text
-
i Lt a 88cv ja UNITED STATES
+j
,o, NUCLEAR REGULATORY COMMISSION E
'n 5 - w '-')(/'
s.
' E REGION 11 o,
tg
[
101 M ARIETT A ST., N W., SulTE 3100 J
AT L ANT A, G EoRGI A 30303
% ' N,-
e' AUG 101979 utEP3EA VENTURLS INC 1,LLU L,t S T E R PUINT VA 23002 Enclosed is IE Bulletin No. 79-19, which requires action by you with regard to your NPC license.
Should you have questions regarding this Bulletin or the actions required of you, please contact this office.
Sincerely, n
9 m.
Q Ja=es P. O'Reilly Director
Enclosures:
1.
List of Bulletins Issued in Last Six Months P00R BRDfll 9092500g7 gyg314
d Accession No:
7908070515 SSINS No:
6820 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 August 10, 1979 IE Bulletin No. 79-19 PACKAGING OF LOW-LEVEL RADI0 ACTIVE WASTE FOR TRANSPORT AND BURIAL Description of Circumstances:
Low-level radioactive waste is that waste which can be transferred and shipped to one of three waste burial facilities which are located in and licensed by the Agreement States of Nevada, South Carolina, and Washington. On July 10, 1979, the Governors of the three states notified NRC Chairman Hendrie of the serious and repeated disregard for rules governing the shipments of low-level radioactive wastes to these burial facilities.
Examples of violations of Agreement State, DOT and NRC rules follow:
improperly packaged uranium fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire end destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.
On July 2, 1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material. The material was described on the bill of lading as being a solid inorganic salt (evaporator concentrates solidified with urea formaldehyde) from a reactor facility. The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.
On July 30, the first shipment into the reopened Beatty facility contained free lic,uid in " solid" material. The radioactive contents were sand filters used at an insitu leaching process at a uranium mill.
Forty-three shipments with sixty-three deficiencies were observed during the package inspection program between April 10 and July 5, 1979, by the Agreement State of South Carolina, at the Barnwell, S.C. burial facility. The shipments were from reactor, medical, industrial and military facilities.
On June 28, 1979, the Federal Highway Administration issued a Notice of Violation to a reactor facility proposing a $10,000 fine for truck contamina-tion resulting from improper closures o for improper loading of the drums on th DUPLICATE DOCUMENT These are a few examples of shipments o facilities which did not fully meet NRC Entire document previously entered which were developed to protect the hea into system under:
Governors of the three States with lice oso SIS that if the situation is not rectified, ANO would deny use of the three burial site f
No. of pages:
p.
blA[dIU
~,: m w -
7,