pa atcg y,

UNITED STATES

',g NUCLEAR REGULATORY COMMISSION y

5 C

W ASHINGTON, D. C. 20555 S

I

%.~....j AUG 101979 MEMORANDUM FOR:

T. Ippolito, Chief, Operating Reactors Branch #3, D0R FROM:

G. Lainas, Chief, Plant Systems Branch, D0R

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION:

FUEL POOL CAPACITY EXPANSION (TAC 11943)

Plant Name:

Edwin I. Hatch Nuclear Plant, Units 1 and 2 Docket Nos. : 50-221 and 50-366 Responsible Branch: ORB #3 Project Manager:

D. Verrelli We have reviewed the Georgia Power Company's submittal for license amendments to expand the spent fuel storage capacity at the Hatch Nuclear Plant.

We find we need the additional information requested in the at.tachment to this memorandum in order to complete our review.

. bw G. Lainas, Chief Plant Systems Branch Division of Operating Reactors

Enclosure:

As stated

Contact:

E. Lantz X27110 cc w/ enclosure:

See page 2

.9/8.334

,9700eno0Q

~

' CC W/ enclosure:

D. Eisenhut B. Grimes W. Gannill G. Lainas MIPC T. Telford W. Russell G. Knighton E. Adensam D. Verre11i E. Lantz D. Fieno W. Brooks tr783. '5 3

5

{

REQUEST FOR ADDITIONAL Iif0RMATION SPENT FUEL POOL CAPACITY EXPANSION EDWIN I. HATCH NUCLEAR PLANT UNITS 1 AND 2 l.

For our evaluation of the differeace between the maximum calculated koo of 0.87 given in your submittal and the maximum actual keft that might occur in the spent fuel pool, the following information should be provided:

a.

The quantity and distribution of the uranium-235 in the fuel pool storage lattice tilculation for this maximum koo.

b.

The quantity and distribution of gadolinium-155 and gadolinium-157 in the fuel pool storage lattice calculation for this maximum koo.

t c.

The quantity and distribution of the fiss'.cn products and actinides in the fuel pool storage lattice calculation for this maximum koo.

2.

On page 7-3 of your submittal you state, The results in Table [7-1 show that the nominal pitch (Case 2) has a higher koo result than the.

minimum pitch case (Case 6)."

Sir ce the statistical error bounJs given on Table 7-1 do not preclude the opp ' site cor.clusion, a.d since all other calculations for similar storage lattices show the opposite to be true, provide a justification.for this conclusion.

4 e

i 378336

,