Forwards LER 79-013/03L-0
Date released: 08/09/2019 Download: ML19207B870


LER 79-013/03L-0:on 790808,decay Heat Boron Concentration Was Not Monitored During Prescribed Interval & Inservice Decay Heat Loop Was Switched W/O Switching Sample Lineup. Caused by Communications Breakdown Between Depts
ML19207B885
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/28/1979
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19207B885 (1)
Forwards LER 79-013/03L-0
ML19207B869
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/28/1979
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19207B869 (1)