Forwards LER 79-084/01T-0
Date released: 08/09/2019 Download: ML19207B116


LER 79-084/01T-0 on 790806:containment Air Coolers Svc Outlet Valves,Automatically Regulated by Inlet Air Temp, Failed to Meet Response Time.Caused by Design Error in Actuator Air Opening Size.Valves Will Be Redesigned
ML19207B117
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/17/1979
From: Rudolph J
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19207B117 (2)
Forwards LER 79-084/01T-0
ML19207B115
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/17/1979
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19207B115 (1)