ML19207B037

From kanterella
Jump to navigation Jump to search
Submits Correction to Copying Error Discovered in 790501 Request for License Amend
ML19207B037
Person / Time
Site: 07000033
Issue date: 06/27/1979
From: Hooper C
TEXAS INSTRUMENTS, INC.
To: Rouse L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 7908230252
Download: ML19207B037 (2)


Text

. _. _

o_

,4. W

(

i TEXAS INSTRUM ENTS INCORPORATED MATER!ALS & ELECTRICAL PRoOUCTS GROUP[@l&

June 27, 1979 RECEIVED

' 21 2

l 21979 > Ip-'

JUL 9

% 8 N.* r,3%

Mr. Leland C.

Rouse, Chief huos b

Fuel Processing & Fabrication Branch

%Q 4,, j 3

Div. of Fuel Cycle & Material Safety V

Cil l 13\\ ']/

Q j

U.S.

Nuclear Regulatory Commission Washington, D.C.

20555

Reference:

SNM-23, Docket 70-33, Request for License Amendment Revisions catec oune 12, 1979, and Request for License Amendment dated May 1, 1979 Gentlemen:

Please accept the attached page change to the May 1,

1979, Enclosure III revision.

This revision was discussed between Mr. Norman Ketzlach, of your staff, and myself to correct a copying error as a result of the current amendment request.

Thank you for your attention in this matter.

Sincerely, 00 A5

[e f

Calvin M.

Hopper Manager, Nuclear Safety bl c-

\\

CMH/ck 9

cCCnTED Attachment ass 1C g

b 5 'S79 > M "g

u sgss C

Q 33NL EctCN f-:

CCCc7 CLB

{

^;s 08~$h O

99 13324 ATTLF90RO, W ASS ACHUS ETTS 32703 e TELEPHONE: 647 222-2000 e CA BLE: TEXINS

E.N.

79-40 TABLE 1 June 27, 1979 Rev. C LOCATION LOCATION NO.

NAME MSO OPERATION GENERAL MFG. AREA (27)

Fuel plate assy.

7 468 gm 2350 or Assemble compacts, 7 24 compacts or 12 frames & covers, assemblies One assy. has 2 compacts (28)

Vacuum storage 8 storage positions Store 'as welded' array

} 468 gm 235U or fuel plate

< 12 assemblies per assemblies.

One position assy. has 2 compacts (29)

Element storage 3 element carts Store 'in process' array or 3 6M containers elements or 'as (near auxiliary 6M containers to received' U308 generator) have 7 9.6 Kg 235U per container

  • (30)

Storage array 10 shipping containers.

Store completed (near overhead 5 inner HFIR elements elements or door) and 5 outer HFIR

'as received' U033 elements with one element per container; or 10 containers with HFBR or similar elements with 7 235U content per element or 10 6M containers 7 9.6 Kg 235U per container; or a total of 10 of any of the above containers 235U Trim edges and/or (31)

Shear 1 468 gm

< 24 fuel plates or ends of fuel 5 6M containers plates,or 7 9.6 Kg 235U per temporarily store container, or 5 HFBR as received U3C8 (or similar) shipping or loaded containers.

containers eld fittings (32)

Weld Milling 1 element cart; maximum w

Machine Shop number of elements being or store worked on in work station elements at a time - 2.

(33)

Miller, Kearney 1 element cart; maximum Mill or store and Trecher number of elements being elements wor < on in work station at a time - 2.

(34)

Drill prass 1 HFBR or similar element Drill holes in elements as

. - gf required.

usp 13321

-