Tennessee Valley Authority, Sequoyah Nuclear Plant, P.O. Box 2000, Soddy Daisy, TN 37384 June 12, 2019 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001
Subject:
Sequoyah Nuclear Plant, Discharge Monitoring Report (DMR), May 2019 Attached is the May 2019 DMR for Sequoyah Nuclear Plant.
Respectfully,
/
Millicent Garland Environmental Scientist
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name JM ^EQUO^HJWC^EAj^LANT _
Address_ _P.a_BOX2000.
(INTEROFFICE OPS^N^ON)
SODDX-JJA1SYJ.N_J7384 FacNity_ jrVA_-^EQlJOYAH.NUCLEAR PLANT j£catjpn_ JHAMILXOJlCfJUNTY:
ATTN:Millicent Garland NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
MAJOR DISCHARGE MONITORING REPORT (DMR)
(SUBR01)
F - FINAL DIFFUSER DISCHARGE EFFLUENT
- NO DISCHARGE
(
j ***
NOTE: Read instructions before completing this form.
Form Approved.
OMB No. 2040-0004 From TN0026450 PERMIT NUMBER 101 G
DISCHARGE NUMBER MONITORING PERIOD YEAR 19 MO 05 DAY I
YEAR 01 j Tol 19 MO 05
-DAY 31 PARAMETER S*
"-v.
QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
EX FREQUENCY OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS TEMPERATURE, WATER DEG.
CENTIGRADE 00010 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT 37.8 04 DEG.C.
0 31/31 RCORDR PERMIT REQUIREMENT Req. Mon.
DAILY MAX CONTI NUOUS CALCTD TEMPERATURE, WATER DEG.
CENTIGRADE 00010 Z
0 INSTREAM MONITORING SAMPLE MEASUREMENT 26.9 04 DEG. C.
0 31/31 MODELD PERMIT REQUIREMENT 30.5 DAILY MX CONTI NUOUS CALCTD TEMP. DIFF. BETWEEN SAMP. &
UPSTRM DEG.C 00016 1
S EFFLUENT GROSS SAMPLE MEASUREMENT 1.6 04 DEG. C.
0 31/31 CALCTD PERMIT REQUIREMENT 3.0 DAILYMX CONTI NUOUS CALCTD FLOW, IN CONDUIT OR THRU TREATMENT PLANT 50050 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT
/7-&L 03 MGD 0
31/31 RCORDR PERMIT REQUIREMENT Req. Mon.
DAILY MAX f CONTI NUOUS RCORDR FLOW, IN CONDUIT OR THRU TREATMENT PLANT 50050 1
0 EFFLUENT GROSS VALUE SAMPLE MEASUREMENT 1724 03 MGD 03 MGD 0
31 /31 CALCTD PERMIT REQUIREMENT Req. Mon.
MOAVG CONTI NUOUS CALCTD CHLORINE, TOTAL RESIDUAL 50060 1
0 EFFLUENT GROSS VALUE SAMPLE MEASUREMENT 0.019 0.034 19 MG/L 0
19/31 GRAB PERMIT REQUIREMENT 0.1 MOAVG 0.1 DAILY MAX FIVE PER WEEK CALCTD TEMPERATURE - C, RATE OF CHANGE 82234 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT 0.2 62 DEG C/HR 0
31/31 CALCTD PERMIT REQUIREMENT 2.0 DAILYMX CONTI NUOUS CALCTD NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Matthew Rasmussen Site Vice President TYPED OR PRINTED COMMENTS ANDEXPLANATION OF ANY VIOLATIONS (Referenceallattachments here)
No closed mode operation. The following injections occurred: FlogardMS6236 (maxcalc. was 0.02852 mg/L, limit is 0.2 mg/L), Spectrus BD 1500 (maxcalc. was 0.047 mg/L, limit is 2.0 mg/L), and Spectrus CT 1300 (max calc. was 0.0332 mg/L, limit is 0.05 mg/L).
I Certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personni properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
EPA Form 3320-1 (REV 3/99)
Previous editions may be used SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT Site Vice President TELEPHONE 423 843-7001 AREA CODE NUMBER DATE 19 06 YEAR MO Page 1 of 1 05 DAY
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name _ jyA L§EQUOYAHJWCJ-E^RJ>>I^NT; _
Address_ _P.O^BOX_2pgp_
ar£LEROFF]CE OPS^I^SON)
SODPX-JJAJSYJ1N_373B4 Facility_ JTVA_-jSEQUOYAH.NUCLEAR PLANT Locat[on_ JHAJWILXOJLWUJNJY ATTN:Millicent Garland NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
MAJOR (SUBR01)
F - FINAL BIOMONITORING FOR OUTFALL 101 EFFLUENT
- NO DISCHARGE j ***
NOTE: Read instructions before completinq this form.
Form Approved.
OMB No. 2040-0004 TN0026450 PERMIT NUMBER 101 T
DISCHARGE NUMBER MONITORING PERIOD YEAR From 19 05 DAY \\
01 YEAR Toi 19 MQ_
05 DAY 31 I PARAMETER "X"
QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
EX FREQUENCY OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS IC25 STATRE 7DAY CHR CERIODAPHNIA TRP3B 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT
>100.0 23 PERCENT 0
2/180 COMPOS PERMIT REQUIREMENT 42.8 MINIMUM SEMI ANNUAL COMPOS IC25 STATRE 7DAY CHR PIMEPHALES TRP6C 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT A*
AAAA
>100.0 23 PERCENT 0
2/180 COMPOS PERMIT REQUIREMENT 42.8 MIMINUM SEMI ANNUAL COMPOS SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Matthew Rasmussen Site Vice President TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Referenceallattachments here)
Toxicity was sampled April 28 - May 3, 2019. The final report is attached.
I Certify under penalty of law that this document and all attachments were prepared under my direction orsupervision inaccordance with a system designed toassurethatqualified personnel^
properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
EPA Form 3320-1 (REV 3/99)
Previous editions may be used Site Vice President SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE 423 AREA CODE 843-7001 NUMBER DATE 19 06 YEAR MO Page 1 of 1 05 DAY
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name J_VA iSE^UO^HJJUO^RJ^Njr _
Address_ _P.O^BOX_200p_
aNTJROFRCE OPS^f^SQN)
SODDY_-JJAJSYJ_TN_37384 FacMity_ _TVA_-_SEQLIOYAH.NUCLEAR PLANT Locatipn_ JHAMLiOJiCJlUirjY ATTN:Millicent Garland NATIONALPOLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
From TN0026450 PERMIT NUMBER 103 G
DISCHARGE NUMBER MONITORING PERIOD YEAR I MO DAY I YEAR MO DAY 19 I 05 01 l Toj 19 05 31 MAJOR (SUBR01)
F - FINAL LOW VOL. WASTE TREATMENT POND EFFLUENT
- NO DISCHARGE
] ***
NOTE: Read instructions before completing this form.
Form Approved.
OMB No. 2040-0004 PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
EX FREQUENCY OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS PH 00400 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT A*
A*
6.5 7.6 12 SU 0
6/31 GRAB PERMIT REQUIREMENT 6.0 MINIMUM 9.0 MAXIMUM ONCE/
WEEK GRAB SOLIDS, TOTAL SUSPENDED 00530 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT AA AA 3.6 3.6 19 0
1 /31 GRAB PERMIT REQUIREMENT 30.0 MOAVG 100.0 DAILY MX MG/L ONCE/
MONTH GRAB OIL AND GREASE 00556 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT AA AA
<4.8
<4.8 19 MG/L 0
1/31 GRAB PERMIT REQUIREMENT 15.0 MOAVG 20.0 DAILY MX ONCE/
MONTH GRAB FLOW, IN CONDUIT OR THRU TREATMENT PLANT 50050 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT 0.951 1.044 03 MGD AA 0
5/31 INSTAN PERMIT REQUIREMENT Req. Mon.
MO AVG Req. Mon DAILY MX ONCE/
WEEK INSTAN SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER ICertify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, ncluding the possibility of fine and imprisonment for knowing violations.
I YJTK%C
^y^i^
TELEPHONE DATE
<fe1¥f Site Vice President SIGNATURE OF PRINCIPAL EXECUTIVE 423 843-7001 19 06 05 OFFICER OR AUTHORIZED AGENT AREA CODE NUMBER YEAR MO DAY Matthew Rasmussen Site Vice President TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANYVIOLATIONS (Reference allattachmentshere)
EPA Form 3320-1 (REV 3/99)
Previous editions may be used Page 1 of 1
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name TVA^E^U^]r^H_NJ^CJ.E^RJPLANT _
Address_ _P O_BOX_2000.
aNIERPFFICE OPS^rtSQN)
SOD.DX-_DAlSY/rN_37384 JFacMity
_TVA_-^EQJJQYAH NUCLEAR PLANT JLocatk>n_ JHAMItJPJlC^UNTY ATTN:Millicent Garland NATIONALPOLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
From TN0026450 PERMIT NUMBER 110 G
DISCHARGE NUMBERi YEAR !
MO.
19 i 05 MONITORING PERIOD.
YEAR I MO I DAY' DAY 01 To 19 05 31 MAJOR Form Approved.
(SUBR01)
OMB No. 2040-0004 F - FINAL RECYCLED COOLING WATER EFFLUENT NO DISCHARGE jXX j ***
NOTE: Read instructions before completinq this form.
PARAMETER "xr QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
EX FREQUENCY OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS TEMPERATURE, WATER DEG.
CENTIGRADE 00010 1
0 EFFLUENT GROSS VALUE SAMPLE MEASUREMENT ft*
04 DEGC PERMIT REQUIREMENT ft*
REPORT DAILY MX CONTIN UOUS CALCTD TEMPERATURE, WATER DEG.
CENTIGRADE 00010 Z
0 INSTREAM MONITORING SAMPLE MEASUREMENT 04 DEGC PERMIT REQUIREMENT 30.5 DAILYMX CONTIN UOUS CALCTD TEMP. DIFF. BETWEEN SAMP. &
UPSTRM DEG.C 00016 1
0 EFFLUENT GROSS VALUE SAMPLE MEASUREMENT ft*
04 DEGC PERMIT REQUIREMENT 5
DAILY MX CONTIN UOUS CALCTD FLOW, IN CONDUIT OR THRU TREATMENT PLANT 50050 1
0 EFFLUENT GROSS VALUE SAMPLE MEASUREMENT 03 MGD ft*
PERMIT REQUIREMENT Req. Mon.
DAILY MX CONTIN UOUS RCORDR CHLORINE, TOTAL RESIDUAL 50060 1
0 EFFLUENT GROSS VALUE SAMPLE MEASUREMENT 19 MG/L PERMIT REQUIREMENT 0.1 MOAVG 0.1 DAILY MX Five per Week CALCTD TEMPERATURE - C, RATE OF CHANGE 82234 1
0 EFFLUENT GROSS VALUE SAMPLE MEASUREMENT 04 DEGC ft*
PERMIT REQUIREMENT 2
DAILY MX CONTIN UOUS CALCTD SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Matthew Rasmussen Site Vice President TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS No Discharge this Period ICertify under penally of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
(Reference all attachments here)
EPA Form 3320-1 (REV 3/99)
Previous editions may be used f**>> Site Vice President SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE 423 AREA CODE 843-7001 NUMBER DATE 19 06 05 YEAR MO DAY Page 1 of 1
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name TVA^EQUO^HjgjJCJ^R^LANT _
Address_ _E Q^BOX2pQ0.
aNJJROmi^OPS^riJQN)
SOJJDY_-JJAJSYJ1N_37384 Facjlity_ JTVA-^EQUOYAH.NUCLEAR PLANT Locator^ JjAMILJPJ^TOUNJY ATTN:Millicent Garland NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
From TN0026450 PERMIT NUMBER 110 T
DISCHARGE NUMBER YEAR i MONITORING PERIOD MO DAY I I YEAR I MO DAY 19 05 01 To l 19 05 31 MAJOR (SUBR01)
F - FINAL RECYCLED COOLING WATER EFFLUENT
- NO DISCHARGE l XX j ***
NOTE: Read instructions before completing this form.
Form Approved.
OMB No. 2040-0004 PARAMETER rxc^
QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
EX FREQUENCY OF SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7DAY CHR CERIODAPHNIA TRP3B 1
0 0
EFFLUENT GROSS VALUE SAMPLE MEASUREMENT ft*
ft***
23 PERCENT PERMIT REQUIREMENT 42.8 MINIMUM SEMI ANNUAL COMPOS IC25 STATRE 7DAY CHR PIMEPHALES TRP6C 1
0 0
EFFLUENT GROSS VALUE SAMPLE MEASUREMENT ftft ftftftft 23 PERCENT PERMIT REQUIREMENT 42.8 MINIMUM SEMI ANNUAL COMPOS SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT
_ll^i NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Matthew Rasmussen Site Vice President TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS No Discharge this Period I Certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel, properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
(Reference all attachments here)
EPA Form 3320-1 (REV 3/99)
Previous editions may be used
£r Site Vice President SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE 423 AREA CODE 843-7001 NUMBER DATE 19 06 05 YEAR MO DAY Page 1 of 1
PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)
Name IY^L§l?^'!i^Ji?LEARJ?^NI_
Address_ J^.a_BOX2p0p_
JiNTEROFFICE OPS^hLSQN)
SODD_Y_-JJAJSYJ[N_37384 Facility__ _TVA_-JEQUOYAH.NUCLEAR PLANJ_
ioqat[on_ JHAMILXOJICOUNrrr:
ATTN:Millicent Garland NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
From TN0026450 PERMIT NUMBER 118 G
DISCHARGE NUMBER!
MONITORING PERIOD I
YEAR 19 MO 05 DAY 01 YEAR MO DAY i
To[ 19 05 31 i MAJOR Form Approved.
(SUBR01)
OMB No. 2040-0004 F-FINAL WASTEWATER & STORM WATER EFFLUENT
- NO DISCHARGE
[XX l ***
NOTE: Read instructions before completinq this form.
PARAMETER S
S QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.
EX FREQUENCY OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS OXYGEN, DISSOLVED (DO) 00300 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT 19 MG/L PERMIT REQUIREMENT 2
MINIMUM TWICE/
WEEK GRAB SOLIDS, TOTAL SUSPENDED 00530 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT M
19 MG/L i
PERMIT REQUIREMENT 100 DAILYMX TWICE/
WEEK GRAB SOLIDS, SETTLEABLE 00545 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT 25 ML/L PERMIT REQUIREMENT 1
DAILY MX ONCE/
MONTH GRAB FLOW, IN CONDUIT OR THRU TREATMENT PLANT 50050 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT 03 MGD PERMIT REQUIREMENT Req. Mon.
MOAVG Req. Mon.
DAILY MX ONCE/
BATCH ESTIMA SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER Matthew Rasmussen Site Vice President TYPED OR PRINTED ICertify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
^W^n^cZ^
£r Site Vice President SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)
During this reporting period, there has been no flow from the Dredge Pond other than that resulting from rainfall. No Discharge this Period EPA Form 3320-1 (REV 3/99)
Previous editions may be used TELEPHONE 423 843-7001 AREA CODE NUMBER 19 YEAR DATE 06 MO Page 1 of 1 05 DAY
PERMITTEE NAME/ADDRESS (Include Facility Name/Location ifDifferent)
Name __JEY* i?EQ^^Hj^CLE^^LANT Address P.O. BOX 2000 aNIERpFFICEOPS^N^QN)
SODDY.- DAJSYJ1N_37384 Facl]ity_ _JVA_-JEQUOYAH NUCLEAR PLANJ Uc^oiL_JH>^l!Jpii-COUi£rY ATTNrMillicent Garland NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)
DISCHARGE MONITORING REPORT (DMR)
MAJOR (SUBR01)
F - FINAL BIOMONITORING FOR OUTFALL 101 EFFLUENT Form Approved.
OMB No. 2040-0004 From JN0026450
^EF^l^MBER I
101 T DISCHARGE NUMBER jyia J DAY J LYJARi MCL I DAY 04 I 01 I To I 19 [ 04 l 30 ymi NO DISCHARGE n
19
^^"\\
QUANTITY OR LOADING AVERAGE^ T 'MAXIMUMH~~"
UNlfsT MINIMUM NOTE: Read instriJ^innft hftfnrp rnmnlptlnn this fnrm PARAMETER QUALITYORTcONCENTRATioN NO.
EX 0
FREQUENCY OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS IC25 STATRE 7DAY CHR CERIODAPHNIA TRP3B 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT
>100.0 23 PERCENT 1/180 COMPOS PERMIT REQUIREMENT 42.8 MINIMUM SEMI ANNUAL COMPOS IC25 STATRE 7DAY CHR PIMEPHALES TRP6C 1
0 EFFLUENT GROSS SAMPLE MEASUREMENT
>100.0 23 PERCENT 0
1/180 COMPOS PERMIT REQUIREMENT 42.8 MIMINUM SEMI ANNUAL COMPOS SAMPLE MEASUREMENT PERMIT REQUIREMENT
" ' 'v!'
""* "' *'/
SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT
- ^\\ ':"* J- '"'V NAME/TITLE PRINClPAj. EXECUTIVE OFFICER Matthew Rasmussen Site Vice President TYPED OR PRINTED COMMENTSI AND EXPLANATION OF ANYVIOLATIONS (Reference all attachments here)
Toxicity wasApril 29-May 3, 2019. The results will be reported in the May DMR.
ICertify under penalty oflaw that thisdocument andall attachments were prepared under my direction orsupervision inaccordance with a systemdesigned toassure thatqualified personnel properly gather andevaluate the information submitted. Basedonmy inquiry ofthe personor persons whomanage the system, orthosepersons directly responsible for gathering the information, the information submitted is, tothebestofmyknowledge andbelief, true, accurate, andcomplete. Iamaware thattherearesignificant penalties for submitting falseinformation, including the possibility of fineand imprisonmentforknowingviolations.
EPA Form 3320-1 (REV 3/99)
Previous editions may be used
^m/^^^^
fV TELEPHONE Site Vice President SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT 423 843-7001 AREA CODE NUMBER DATE 19 YEAR MO Page 1 of 1 04 DAY