NUREG/CR-6850 FIRE PRA METHODOLOGY Module 1 Internal Event, At-Power Probabilistic Risk Assessment Model for SNPP Task 15: Uncertainty and Sensitivity Analysis Nicholas Melly - Nuclear Regulatory Commission Fire PRA Workshop June 24, 2019 - June 28, 2019 Rockville, MD U.S. NRC HQ

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 2 Task 15:Uncertainty and Sensitivity Analysis Purpose (per 6850/1011989)

Purpose:

Provide a process for identifying and treating uncertainties in the Fire PRA, and identifying sensitivity analysis cases Many of the inputs to the Fire PRA are uncertain Important to identify sources of uncertainty and assumptions that have the strongest influence on the final results Fire risk can be quantified without explicit quantification of uncertainties, but the risk results cannot be considered as complete without it Sensitivity analysis is an important complement to uncertainty assessment

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 3 Task 15:Uncertainty and Sensitivity Analysis Scope Scope of Task 15 includes:

Background information on uncertainty Classification of the types of uncertainty A general approach on treating uncertainties in Fire PRA

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 4 Uncertainty and Sensitivity Analysis -

Corresponding PRA Standard Element Primary match is to element UNC - Uncertainty and Sensitivity Analysis UNC Objectives (as stated in the PRA standard):

(a) identify sources of analysis uncertainty (b) characterize these uncertainties (c) assess their potential impact on the CDF and LERF estimates

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 5 Uncertainty and Sensitivity Analysis HLRs (per the PRA Standard)

HLR-UNC-A: The Fire PRA shall identify sources of CDF and LERF uncertainties and related assumptions, and modeling approximations. These uncertainties shall be characterized such that their potential impacts on the results are understood.

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 6 Task 15:Uncertainty and Sensitivity Analysis Types of Uncertainty Distinction between aleatory and epistemic uncertainty:

Aleatory - From the Latin alea (dice), of or relating to random or stochastic phenomena. Also called random uncertainty or variability

Reflected in the Fire PRA models as a set of interacting random processes involving a fire-induced transient, response of mitigating systems, and corresponding human actions Epistemic - Of, relating to, or involving knowledge; cognitive. (From Greek episteme, knowledge.) Also called state-of-knowledge uncertainty

Reflects uncertainty in the parameter values and models (including completeness) used in the Fire PRA - Addressed in this Task

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 7 Task 15:Uncertainty and Sensitivity Analysis Inputs and Outputs Inputs from other Tasks:

Identification of sources of epistemic uncertainties from Tasks 1 through 13 worthy of uncertainty/sensitivity analysis (i.e., key uncertainties)

Quantification results from Task 14 including risk drivers used to help determine key uncertainties Proposed approach for addressing each of the identified uncertainties including sensitivity analyses Outputs to other Tasks:

Sensitivity analyses performed in Task 14 Results of uncertainty and sensitivity analysis are reflected in documentation of Fire PRA (Task 16)

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 8 Task 15:Uncertainty and Sensitivity Analysis General Procedure (per 6850/1011989)

Addresses a process to be followed rather than a pre-defined list of epistemic uncertainties and sensitivity analyses, since these could be plant specific Step 1: Identify uncertainties associated with each task Step 2: Develop strategies for addressing uncertainties Step 3: Review uncertainties to decide which uncertainties to address and how Step 4: Perform uncertainty and sensitivity analyses Step 5: Include results of uncertainty and sensitivity analyses in Fire PRA documentation

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 9 Task 15:Uncertainty and Sensitivity Analysis Steps in Procedure/Details See Appendix U to NUREG/CR-6850 for background on uncertainty analysis. See Appendix V for details for each task.

Step 1: Identify epistemic uncertainties for each task Initial assessment of uncertainties to be treated is provided in Appendix V to NUREG/CR-6850 (but consider plant specific analysis for other uncertainties such as specific assumptions)

From a practical standpoint, characterize uncertainties as modeling and data uncertainties Outcome is a list of issues, by task, leading to potentially important uncertainties (both modeling and data uncertainty)

Related SRs:

PRM-A4, FQ-F1, IGN-A10, IGN-B5, FSS-E3, FSS-E4, FSS-H5, FSS-H9, and CF-A2 for sources of uncertainty

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 10 Task 15:Uncertainty and Sensitivity Analysis Steps in Procedure/Details (Cont.)

Step 2: Develop strategies for addressing uncertainties Strategy can range from no action to explicit quantitative modeling Each task analyst is expected to provide suggested strategies Possible strategies include propagation of data uncertainties, developing multiple models, addressing uncertainties qualitatively, quality review process, and basis for excluding some uncertainties Basis for strategy should be noted and may include importance of uncertainty on overall results, effects on future applications, resource and schedule constraints

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 11 Task 15:Uncertainty and Sensitivity Analysis Steps in Procedure/Details (Cont.)

Step 3: Review uncertainties to decide which uncertainties to address and how Review carried out by team of analysts familiar with issues, perhaps meeting more than once Review has multiple objectives:

Identify uncertainties that will not be addressed and reasons why

Identify uncertainties to be addressed and strategies to be used

Identify uncertainties to be grouped into single assessment

Identify issues to be treated via sensitivity analysis

Instruct task analysts who perform the analyses

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 12 Task 15:Uncertainty and Sensitivity Analysis Sensitivity Analysis Sensitivity analysis can provide a perspective that cannot be obtained from a review of significant risk contributors Each task analyst can provide a list of parameters that had the strongest influence in their part of the analysis Experiment with modified parameters to demonstrate impact on the final risk results Modeling uncertainties can be demonstrated through sensitivity analysis Sensitivities should be performed for individual uncertainties, as well as for appropriate logical groups of uncertainties

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 13 Task 15:Uncertainty and Sensitivity Analysis Steps in Procedure/Details Step 4: Perform uncertainty and sensitivity analyses Uncertainty analyses may involve:

Quantitative sampling of parameter distributions

Manipulation of models to perform sensitivity analyses

Qualitative evaluation of uncertainty Following items should be made explicit:

Uncertainties being addressed

Strategy being followed

Specific methods, references, computer programs, etc. being used (to allow traceability)

Results of analyses, including conclusions relative to overall results of Fire PRA

Potential impacts on anticipated applications of results

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 14 Task 15:Uncertainty and Sensitivity Analysis Steps in Procedure/Details (Cont.)

Step 5: Include results in PRA documentation Adequate documentation of uncertainties and sensitivities is as important as documentation of baseline results Adequate documentation leads to improved decision-making Documentation covered more fully under Task 16

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 15 Task 15:Uncertainty and Sensitivity Analysis Expectations Minimum set of uncertainties expected to have a formal treatment:

Fire PRA model structure itself, representing the uncertainty with regard to how fires could result in core damage and/or large early release outcomes (Tasks 5/7)

Uncertainty in each significant fire ignition frequency (Task 6)

Uncertainty in each significant circuit failure mode probability (Task 10)

Uncertainty in each significant target failure probability (Task 11)

- Heat release rate

- Suppression failure model and failure rate

- Position of the target set vs. ignition sources Uncertainty in each significant human error probability (Task 12)

Uncertainty in each core damage and large early release sequence frequency based on the above inputs as well as uncertainties for other significant equipment failures/modes (Task 14)

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 16 Other uncertainties may be relevant to address Other activities related to uncertainty are underway You might need to consult other resources for information (e.g.,

NUREG-1855, EPRI TR 1016737)

Sensitivity analyses should be performed where important to show robustness in results (i.e., demonstrate where results are / are not sensitive to reasonable changes in the inputs)

While not really a source of uncertainty, per se, technical quality issues and recommended reviews are also addressed Task 15:Uncertainty and Sensitivity Analysis Expectations (Cont.)

Fire PRA Workshop 2019, Rockville, MD Module 1: Internal Event, At-Power PRA Model for SNPP Slide 17 Mapping HLRs & SRs for the UNC Technical Element to NUREG/CR-6850, EPRI TR 1011989 Technical Element HLR SR 6850/101198 9 section that covers SR Comments A

The Fire PRA shall identify sources of CDF and LERF uncertainties and related assumptions and modeling approximations. These uncertainties shall be characterized such that their potential impacts on the results are understood 1

15.5.1 2

15.5.5 Documentation is discussed in Section 16.5 of 6850/101198