COLLEGE OF ENGINEERING THE UNIVERSITY OF TEXAS AT AUSTIN Depart111ent ef Mechanical Engineering* I University Station C2200
- A11Jti11, T exaJ 7 8712-0292 Telepho11e(512)471-1131 FAX (512)471-8727 Walker Department ofMechanical Engineering THE UNIVERSITY OF TEXAS AT AUSTIN N11clearE11gi11ee1i11g Teaching Laborato1y
- m1c/em:e11g,:ufexas.ed11 10100 Bwnet Rd (PRC 159), R9000 *A.11sti11, Te:r.:as
- 78758* (512) 232-5371 *Fax (512) 471-4589 U.S. Nuclear Regulatory Commission Attn: Document Control Washington, DC, 20555-0001 W.Kennedy USNRC Program Manger
Subject:
Submission of Changes to License Emergency Plan under 10CFR50.54(q)
Ref: The University of Texas at Austin Facility License R-129, Docket 50-602 Sir:
25 April 2019 Attached please find a revised copy of the Emergency Response Plan (ERP) for The University of Texas at Austin, Nuclear Engineering Teaching Laboratory.
Motivation for this revision originated with an evaluation of the ERP classification. While it was determined that the ERP does not contain information that would require the previous classification of 'OFFICAL USE ONLY,' the review also identified the need to (1) incorporate the impact from changes in the University administrative structure, site infrastructure, and off-site support organizations, (1) correct grammatical errors, (2) better integrate with the National Incident Management System model, and (3) improve the presentation of information. A summary of the changes and evaluation are attached, along with the revised Emergency Response Plan, Revision 4.
The ERP was reviewed by the University Preparedness Office. The proposed ERP revision was reviewed by the Reactor Oversight Committee on 15 April 2019, evaluated to not reduce the effectiveness of the ERP, and approved. Please contact me by phone at 512-232-5373 or email whaley@mail.utexas.edu if you require additional information.
P. MWhaley Associate Director Nuclear Engineering Teaching Laboratory The University of Texas at Austin Att:
- 1.
- 2.
Summary of Emergency Plan Changes Under Revision 4 Emergency Response Plan, Docket 50-602, License R-129-Revision 4
..I