ML19115A068
| ML19115A068 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry |
| Issue date: | 04/25/2019 |
| From: | NRC/RGN-II/DRS/OLB |
| To: | Tennessee Valley Authority |
| References | |
| 50-259/18-01, 50-260/18-01, 50-296/18-01 50-259/OL-18-01, 50-260/OL-18-01, 50-296/OL-18-01 | |
| Download: ML19115A068 (27) | |
Text
Browns Ferry ES-201-3 Note: Emails for signatures obtained by email were not attached due to containing PII.
ES-301 Competencies Checklist Form ES-301-6 Facility: Browns Ferry NPP Date of Examination:16 JULY 2018 Operating Test No.: ILT 1804 APPLICANTS RO SRO-I(1)
SRO-U RO SRO-I(2)
SRO-U RO(1)
SRO-I SRO-U RO(2)
SRO-I SRO-U Competencies SCENARIO SCENARIO SCENARIO SCENARIO 1
2 3
4 1
2 3
4 1
2 3
4 1
2 3
4 Interpret/Diagnose Events and Conditions 2,3, 4,5, 6,7, 8,9 3,7, 8,9 3,4, 5,6, 7,8, 9,
10 2,3, 4,5, 6,7, 8,9 3,7, 8,9 3,4, 5,6, 7,8, 9,
10 4,6, 7,8, 9
4,6, 9,
10, 11 2,3, 5
2,3, 6,7 1,4, 6,8, 9,
10 Comply With and Use Procedures (1) 2,3, 4,5, 6,7 2,3, 7,8, 10 2,3, 4,5, 6,7, 8,9, 10 2,3, 4,5, 6,7 2,3, 7,8, 10 2,3, 4,5, 6,7, 8,9, 10 1,4, 6,7 1,4, 6,9, 10, 11 2,3, 5,8 2.3, 6,7 1,4, 6,8, 10 Operate Control Boards (2) 2,3, 7,8, 10 2,3, 7,8, 10 1,4, 7,9 1,4, 6,9, 10, 11 2,3, 5,8 2,3, 6,7 1,4, 6,8, 9,
10 Communicate and Interact 2,3, 4,5, 6,7 2,3, 7,8, 10 2,3, 4,5, 6,7, 8,9, 10 2,3, 4,5, 6,7 2,3, 7,8, 10 2,3, 4,5, 6,7, 8,9, 10 1,4, 6,7, 8,9 1,4, 6,9, 10, 11 2,3, 5,8 2,3, 6,7 1,4, 6,8, 9,
10 Demonstrate Supervisory Ability (3) 3,4, 6,7 2,4, 5,6, 8,
10 3,4, 6,7 2,4, 5,6, 8,
10 Comply With and Use Tech. Specs.
(3) 2,5 3,7 2,5 3,7 Notes:
(1)
Includes Technical Specification compliance for an RO.
(2)
Optional for an SRO-U.
(3)
Only applicable to SROs.
Instructions:
Check the applicants license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant. (This includes all rating factors for each competency.) (Competency Rating factors as described on forms ES-303-1 and ES-303-3.)
ES-301 Competencies Checklist Form ES-301-6 Facility: Browns Ferry NPP Date of Examination:16 JULY 2018 Operating Test No.: ILT 1804 APPLICANTS RO(3)
SRO-I SRO-U RO(4)
SRO-I SRO-U RO(5)
SRO-I SRO-U Competencies SCENARIO SCENARIO SCENARIO 1
2 3
4 1
2 3
4 1
2 3
4 Interpret/Diagnose Events and Conditions 4,6, 9,
10, 11 2,3, 5
4,6, 7,8, 9
3,7, 8,9 2,3, 6,7 4,6, 9,
10, 11 1,4, 6,8, 9,
10 Comply With and Use Procedures (1) 1,4, 6,9, 10, 11 2,3, 5,8 1,4, 6,7 2,3, 7,8, 10 2.3, 6,7 1,4, 6,9, 10, 11 1,4, 6,8, 10 Operate Control Boards (2) 1,4, 6,9, 10, 11 2,3, 5,8 1,4 7,9 2,3, 7,8, 10 2,3, 6,7 1,4, 6,9, 10, 11 1,4, 6,8, 9,
10 Communicate and Interact 1,4, 6,9, 10, 11 2,3, 5,8 1,4, 6,7, 8,9 2,3, 7,8, 10 2,3, 6,7 1,4, 6,9, 10, 11 1,4, 6,8, 9,
10 Demonstrate Supervisory Ability (3)
Comply With and Use Tech. Specs.
(3)
Notes:
(1)
Includes Technical Specification compliance for an RO.
(2)
Optional for an SRO-U.
(3)
Only applicable to SROs.
Instructions:
Check the applicants license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant. (This includes all rating factors for each competency.) (Competency Rating factors as described on forms ES-303-1 and ES-303-3