Enclosure 7 to E-53778 Listing of Computer Files Contained in Enclosure 8 Disk ID No.
(size)
Discipline System/Component (Calculation Number)
File Series (topics)
Number of Files One Computer Hard Drive Total (185.86 GB)
Shielding (2.25 GB)
Structural (9.61 GB)
Thermal (174.00 GB)
Shielding EOS-TC108 / EOS-37PTH DSC Section 6.4.3 EOS-TC108 Dose Rates for EOS-37PTH DSC HLZC 4 and 5 Folder:\\Shielding\\Section 6.4.3 EOS-TC108 37PTH subfolders for HLZC 4 and HLZC 5 44 EOS-TC125 / EOS-37PTH DSC Section 6.4.3 EOS-TC125 Dose Rates for EOS-37PTH DSC HLZC 4 and 10 Folder:\\Shielding\\Section 6.4.3 EOS-TC125 37PTH subfolders for HLZC 4 and HLZC 10 44 EOS-TC125 Failed /
EOS-37PTH DSC Section 6.4.3 EOS-TC125 Dose Rates for EOS-37PTH DSC with Failed Fuel Folder:\\Shielding\\Section 6.4.3 EOS-TC125failed 37PTH subfolders for HLZC 8 and HLZC 10 68 EOS-HSM / EOS-37PTH DSC Section 6.4.4 EOS-HSM Dose Rates for EOS-37PTH DSC Folder:\\Shielding\\Section 6.4.4 EOS-HSM 37PTH subfolders for single reflection, double reflection, triple reflection, and accident 40 EOS-HSM Offsite /
EOS-37PTH DSC Section 11.3 EOS-HSM Offsite Dose Rates for EOS-37PTH DSC Folder:\\Shielding\\Section 11.3 EOS-HSMoffsite 37PTH subfolders for 2x10 and 2_1x10 12 HSM-MX / EOS-37PTH DSC Section A.6.4.4 HSM-MX Dose Rates for the EOS-37PTH DSC Folder:\\Shielding\\Section A.6.4.4 HSM-MX 37PTH subfolders for single reflection, double reflection, triple reflection, accident, construction joint, and construction joint accident 58 HSM-MX Offsite / EOS-37PTH DSC Section A.11.3 HSM-MX Offsite Dose Rates for EOS-37PTH DSC Folder:\\Shielding\\Section A.11.3 HSM-MXoffsite 37PTH subfolders for 2x11, 2_1x11, and 2x11accident 18 Page 1 of 3 to E-53778 Listing of Computer Files Contained in Enclosure 8 OS197 / 61BTH Section B.6.4.3 OS197 Dose Rates for the 61BTH DSC Folder:\\Shielding\\Section B.6.4.3 OS197 61BTH subfolders for transfer and accident 10 HSM-MX / 61BTH Section B.6.4.4 HSM-MX Dose Rates for the 61BTH DSC Folder:\\Shielding\\Section B.6.4.4 HSM-MX 61BTH 10 Structural NUHOMS Matrix /
61BTH Type 2 DSC Structural Analysis in HSM-MX Appendix B.3.9.1 Folder: \\Structural\\DSC\\SEIST20 Input and output files for the DSC seismic load case (ANSYS Evaluation)
Load combination 3 in Appendix B.3.9.1.2.5.8 includes:
- Dead weight
- Internal pressure of 20 psi
- Seismic load (Top Load) 8 Appendix B.3.9.1 Folder: \\Structural\\DSC\\SEISB20 ANSYS input and output files for the DSC seismic load case: Load combination 3 in Appendix B.3.9.1.2.5.8 including
- Dead weight
- Internal pressure of 20 psi
- Seismic load (Bottom Loading) 8 Thermal NUHOMS MATRIX with 61BTH Type 2 DSC for Normal Hot storage with HLZC 7 and coarse mesh Appendix B.4.4.1 (LC 1a in Table B.4-1)
Folder: \\Thermal\\1-MATRIX-61BTH-LC1a-Normal-coarse Input and output files for the bounding normal hot storage condition with 15 mph side wind, HLZC 7, and coarse mesh (ANSYS FLUENT Evaluation) 31 NUHOMS MATRIX with 61BTH Type 2 DSC Normal Hot storage evaluation with HLZC 7 and fine mesh Appendix B.4.4.1 (LC 1b in Table B.4-1)
Folder: \\Thermal\\2-MATRIX-61BTH-LC1b-Normal-fine Input and output files for the bounding normal hot storage condition with 15 mph side wind, HLZC 7, and fine mesh (ANSYS FLUENT Evaluation) 29 NUHOMS MATRIX with 61BTH Type 2 DSC for Bounding accident storage evaluation with HLZC 7 and fine mesh Appendix B.4.4.1 (LC 3 in Table B.4-1)
Folder: \\Thermal\\3-MATRIX-61BTH-LC3-Accident-fine Input and output files for the accident storage condition for 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br />, HLZC 7, and coarse mesh (ANSYS FLUENT Evaluation) 18 Page 2 of 3 to E-53778 Listing of Computer Files Contained in Enclosure 8 NUHOMS EOS-HSM with EOS-37PTH DSC for Normal hot storage evaluation with HLZC 10 Appendix 4.9.7.2.1 (LC 1n and LC 2n in Table 4.9.7-1)
Folder: \\Thermal\\4-EOS_HSM-37PTH-LC1n_LC2n Input and output files for the normal hot storage condition with 8 mph wind, HLZC 10 (ANSYS FLUENT Evaluation)
- Subfolder LC1n: EOS-HSM with wind deflectors (Heat Load 45.7 kW).
- Subfolder LC2n: EOS-HSM without wind deflectors (Heat Load 41.8 kW).
20 EOS-TC125 with EOS-37PTH DSC for Bounding normal hot and accident transfer evaluation with HLZC 10 Appendix 4.9.7.2.2 (LC 1 and LC 5 in Table 4.9.7-3)
Folder: \\Thermal\\5-EOS-TC125-37PTH-HLZC10 Input and output files for the bounding normal hot indoor transfer condition and accident outdoor transfer condition, HLZC 10 (ANSYS FLUENT Evaluation)
- Subfolder LC1_Transient: Files for LC 1.
Subfolder LC5_Accident: Files for LC 5.
26 NUHOMS MATRIX with EOS-37PTH DSC with Basket Type 4H for HLZC 11 Appendix A.4.6 (LC 1e-S for HLZC 11 of Table A.4-34)
Folder: \\Thermal\\6-HSM-MX-LC_1e-S_HLZC11 Input and output files for the bounding normal hot storage condition with 15 mph side wind, HLZC 11 (ANSYS FLUENT Evaluation) 17 EOS-TC108 with EOS-37PTH DSC for Bounding normal hot transfer evaluation with HLZC 4 Appendix 4.9.6.3 (LC 1 of Table 4.9.6-12 with HLZC4)
Folder: \\Thermal\\7-EOS-TC108_EOS-37PTH__HLZC4 Input and output files for the bounding normal hot indoor transfer condition, HLZC 4 (ANSYS FLUENT Evaluation) 11 Page 3 of 3