ML19101A339
| ML19101A339 | |
| Person / Time | |
|---|---|
| Site: | Holtec |
| Issue date: | 04/05/2019 |
| From: | Tomlinson J Holtec |
| To: | Yen-Ju Chen Document Control Desk, Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML19101A335 | List: |
| References | |
| 5014870 | |
| Download: ML19101A339 (2) | |
Text
HOLTE.C Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax(856)797-0909 INTERNATIONAL April 5, 2019 Yen-Ju Chen Sr. Project Manager - Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1014, Certificate of Compliance (CoC) No. 1014
Subject:
Submittal of Responses to Clarification Questions for Holtec's Response to NRC's 1st Round RAis for HI-STORM 100 Amendment Number 14 Reference(s): [1] "Amendment No. 14 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Additional Information" (Letter from Yen-Ju Chen (NRC) to Joyce Tomlinson (Holtec) dated January 24, 2019)
[2] "Submittal of Responses to NRC's I51 Round RAis for HI-STORM 100 Amendment Number 14" (Letter from Joyce Tomlinson (Holtec) to Yen-Ju Chen (NRC) dated February 28, 2019)
[3] "Clarification Questions for HI-STORM Amd 14 RAI Response" (Email from Yen-Ju Chen (NRC) to Joyce Tomlinson (Holtec) dated March 15, 2019)
Dear Ms. Chen:
In response to the phone call between the NRC staff and Holtec staff, March 20, 2019, the following information is provided to address the questions outlined in the referenced email [3].
As discussed, FSAR section 2.1.3.1 and Figure 2.1.10 have been revised to provide additional information regarding the DFis. to this letter contains the responses to the clarification questions attached in [3]. contains the proposed FSAR changed pages. The FSAR utilizes track changes and yellow highlighting to identify the changes specific to the RAI responses -and clarification questions, to differentiate them from track changes used for the original submittal.
If you have any questions, please contact me at 856-797-0900 ext. 3765.
Document ID 5014870 Page 1 of2
HOLTEC INTERNATIONAL Sincerely, Joyce omlinson Adjunct Licensing Manager, Holtec International cc:
(via email)
Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Mike Layton (USNRC),
Attachments: : Response to Clarification Questions for Additional Information (RAis) Response for HI-STORM 100 LAR 1014-14 (non-proprietary) : HI-STORM 100 FSAR (Proposed Rev. l6B), changed pages (non-proprietary)
Document ID 5014870 Page 2 of2