Text
e e
VIRGINIA. ELECTRIC AND POWER COMPANY RIOHMOND,VIHGINIA 23261 July Mr. Edson G. case, Acting Director Office of Nuclear Reactor Regulation Attn:
Mr. RG>bert W. Reid, Chief 22*, 1977 Serial No. 311 U)A/DWSjr:krb Operating Reactors Branch No. 4 Division of Cperat.ing Reactors U. S. Nuclear Regulatory Carmission Washington, D. C.
20555 Ibcket Nos.
50-280 50-~---
. License Nos. ~~2:,y,**,-,~
/TIPR~37- *--- -*.J :,
.,,-* *-*~-::,.,:--~ \\*~,
.. ~,.:'~
Dear Mr. Case:
~.-.. -.. **~~*
. ~':!1:-C>*, -~
AMENDMENT TO THE OPERATING LICENSE TECHNICAL SPECIFICATICN CHANGE NO. 55 SURRY *POWER STATION
- Pursuant to 10 CFR 50.90, the Virg.inia Electric and POW=r ca~lrfy" hereby requests an amendment to Ope.rat.ing Licenses DPR-32 and DPR-37 for
~
Surry Power Station Unit Nos. 1 and 2.
The Amendment requested is a change to the Technical Specifications and has been designated as Change No. 55.
The bases for our request is to clarify the Technical Specification to reflect the actual inservice inspection being perfonred at SUrry. In addi-tion, VEPCO personnel and NRC I&E inspectors are in agreement that the changes are necessary.
The changes are as fallows:
- 1. The Technical Specification Table 4.2-1, Item 4.1, category F, requires a ur,NT/Pl' for vessel, pump or valve safe end to pipe welds and states that these examinations are covered individually under the various section (A, B, and C)
- Ha.sver, Section B, category F, "Pressurizer Surge Lille to outlet Nozzle" requires only a volumetric examination (UT).
- 2. T.S. Table 4.2-1, Iten l.ll, category G-2 states that bolting less than 2 inches in diameter is not applicable because none exists. Ha.sver, conoseal bolting on the reactor head is included in the cate-gory and was examined.
There are no safe end welds in branch pip.ing in SUrry Unit
- 1. These welds do not exist.in Surry Unit 2.
- 4. T.S. Table 4.2-1, Item 4.7, Category J-2 requires a visual examination of 50% of the circumferential and longitudinal pipe welds and branch pipe connec-tions prior to the end of the 5 year interval. How-ever, ASME XI requires that those welds excluded by Article IS-121 shall be visually examined only when-ever the systen boundary is subjected to a true hydro-static test, prior to each plant startup following
------*~-
772080:308
e
':Umo1NIA ELECTR1c AND PowER CoMPANY To Mr. F.clson G. case, Acting Director refueling, and at the time of the system hydrostatic test as required by IS-520.
Page 2
- 5. Surry T.S. Table 4.2-1, Item 5.5, category G-2, requires that pressure retaining bolting below 2 inches in diameter would be visually examined whenever the bolting connection is dissembled for maintenance purposes. This requirement, however, exceeds the intent of ASME XI.
- 6. T.S~ Table 4.2-1, Item 5.6, category K-1, requires a visual and volumetric examination of integrally welded supports in the pump pressure botmdary. H~ver, the geanetric configuration does not pennit a volumetric examination.
- 7. T.S. Table 4.2-1, Item 8.1.3, category J-1 requires an inspection. of sensitized steel socket welds. and branch connection welds 4 inches in diameter and smaller. How-ever, there are no welds of this type in Surry Unit 1.
The welds do exist in Surry Unit 2.
- 8. T.S. Item 4.15, "Augmented Inservice Inspection Program for High Energy Lines O:ttside of Containment" requires an examination of the 20 welds which are identified in T.S. Figure 4.15 as rupture points. ~er, welds 1, 135, and 275 are inaccessable.
These changes have been revi~ by both the Station Nuclear Safety and Operating Ccmnittee and the System Nuclear Safety and Operating carmittee.
Fur-ther, it has been detenni.ned that these changes do not involve an unreviewed safety question as defined in 10 CFR 50.59.
Attachment cc: Mr. Nonnan c. Moseley Very truly yours,
~...-..
,,... _../ /-. *--...
jt---~~;
C Stallin
- ~-
- M.
gs Vice President-P~ SUpply and Production Operations
e e
(SEAL)
Attest:
C(M,X)NWEALTH OF VIRGINIA )
) S.S.
CITY OF RICHMJND
)
Before me, Rotert M. Neil, a Notary Public, in and for the City and C~alth aforesaid, on the 22nd day of July, 1977, personally appeared W. L. Proffitt and G. P. Morecock, who being duly swom, made oath and said (1) that they are Senior Vice President and Assistant Secre-tary, respectively, of the Virginia Electric and PO'W:r Company, (2) that they are duly authorized to execute and file the foregoing Amendment in behalf of that canpany, and (3) that the statements in the Arnendrralt are true to the best of their knowledge and belief.
(SEAL)
Given under my hand and notarial seal this 22nd day of July, 1977.
My Ccmnission expires January 2 0, 1981.
,f/;;:~/t7 );:7/ );:;,:/,./
Rol:eft M. Neil Notary Public