Mr. Benard C. Rusche Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Connnission Washington, D. C.

20555 Attn:

Mr. Robert W. Reid, Chief Operating Reactors Branch 4

Dear Mr. Rusche:

e Serial No. 199 PO&M/JTB:clw Docket Nosw 50-280 50-281 License Nos. DPR-32 DPR-37 In our letter of May 20, 1976, Serial No. 557A, we provided a schedule for submitting certain information regarding the Appendix I analysis for the Surry Power Station, Unit Nos. 1 and.2.

Enclosed is the information identified as Items II-2 and II-8.

Item II-2 is a summary of the land use data required for the analysis.

Item II-8 consists of a table showing the topographic highlights for a distance of Oto 10 miles around the site for the 16 cardinal compass points.

The requested topographic maps are enclosed.

As we have indicated previously, the analysis is scheduled to be completed in October 1976 by our consultant.

As additional data becomes available we will submit it to you.

Enclosures cc:

Mr. Norman C. Moseley Very truly yours, to_ J21. -yff&L1~*~

C. M. Stallings Vice President-Power Supply and Production Operations I

e o::-..s Mile Highpoints by Mile and 5-10 Mile Highpoints for 15 Caxdinal Poi*nts fro:n Surry Po-,,H:r Station ""

Direction 0 - 1 1*- 2 2 - 3

~ 4 - 5 S - 1 O (miles}

N 37 12 55 80

~"NE 37 5

2 71 100 NE 38 4

52 80

. -ENE 43 10 30 so E

38 3

60 ESE 38 37 11 30 SE 39 35 SSE 39 33 39 37 37 50 s

37 39 so 51 60 80

&:"Vl 42 38 42 70 85 90 SV{

. 39 70 72 84 ss

.,;J&&

\\VS\\V 40 55 Sl 83 130

\\V 3S 1()

88 90 WriW' 39 10

. ~'VI 38 6

5 80 I

. ~l/{

39 12 47 110

  • All-highpoints ere measu..""ed in feet. Dash {-) denotes sea leveL I

r Sources: *sucy Fewer Station Units 3 and 4 Emtirorunental Report-,

i'igures 2.6-3 through 2.6-11; and U.S. Geological Survey 7.5 minute topographic maps *.

Jr._.*

l

~"'

I APPENDIX I ANALYSIS Miscellaneous information regarding the area within five miles

..r:

01 t-he Surry Power Station Mi 1 k Mi 1 k Beef DIRECTION RES I DENCE GARDEN

  • cow GOAT CATTLE HOGS CHICKEN DUCK N

NNE 1.90 4.28 1.50 NE 4.92 4.82 t.45 EN.E 4.77 E*

ESE SE SSE 4.48 2.95

  • s
1. 53 1.54 t"~I.I 1 "7

., 17

.J.Jn

.. e I/

-**I SW

1. 79
2. 10 4.13 WSW 2.8 3.0 3.21 3.21 w

3.21 3.59 4.22 WNW NW 4.o NNW 3-.70 3i75

~

NOTE:

Units are in statute miles