VIRGINIA ELECTRIC AND POWER COMP.ANY RICHMOND, VIRGINIA 2 3 2 61 September 16, 1977 Mr. Edson G. Case, Acting Director Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attn:

Mr. Robert W. Reid, Chief Operating Reactors, Branch 4

Dear Mr. Case:

Serial No. 298A PO&M/ TAP : das Docket No. 50-281 License No. DPR-37 In our letter of July 17, 1977, concerning Surry Unit No. 2 July shutdown, we identified a "2C" Steam Generator leaking hot leg tube at Row 4 Column 63.

A further review of our eddy current records of the April 1977 outage has re-vealed that this tube did not pass either a 0.650 probe or a 0.610 probe and should have been plugged at that time.

Therefore, if our plugging program had been perfectly implemented, the July shutdown could have been averted.