ML19093A971

From kanterella
Jump to navigation Jump to search
Response to Request for Additional Information Concerning High Density Spent Fuel Storage Racks, Surry Power Station Units 1 & 2
ML19093A971
Person / Time
Site: Surry  
Issue date: 09/29/1977
From: Stallings C
Virginia Electric & Power Co (VEPCO)
To: Case E, Reid R
Office of Nuclear Reactor Regulation
References
Download: ML19093A971 (1)


Text

e VIRGINIA ELECTRIC A.ND POWER COMP.A.NY RIOHMOND, VIRGINIA. 23261 September 29~ 1977 Mr. Edson G. Case, Acting Director Office of Nuclear Reactor Regulation Attn:

Mr. Robert W. Reid, thief Operating Reactors Branch No. 4 Divisirin of Operating Reactors U.S. Nuclear Regulatory Commission Washington, D. C.

20555

Dear Mr. Case:

Serial No. 376/082577 PO&M/HSM:bep/mc Docket Nos. 50-280 50-281 License Nos. DPR-32 DPR-37 RESPONSE TO'REQUEST FOR ADDITIONAL INFORMATION

. HIGH DENSITY SPENT FUEL.STORAGE RACKS

. SURRY POWER STATION UNITS l AND 2 The attached information concerning the High Density Spent Fuel Storage Racks for Surry Units l and 2 is being* provided in response to your letter of August 25, 1977.

Attachments Very truly yours,

~- }J1. y#atlr~r*

C. M. Stallings Vice President - Power Supply and Production Operations cc:

Mr. James P. O'Reilly, Director Office of Inspection & Enforcement Region II