1 NRR-DMPSPEm Resource From:
Lamb, John Sent:
Monday, April 1, 2019 10:29 AM To:
richard.dunn@dnr.ga.gov; barty.simonton@dnr.ga.gov; jeff.morrison@gema.ga.gov
Subject:
For Your Comments - State of Georgia - Vogtle Turbine-Driven Auxiliary Feedwater Pump License Amendment Request Attachments:
LTR 19-2018.pdf Importance:
High Mr. Dunn, Mr. Simonton, and Mr. Morrison:
The U.S. Nuclear Regulatory Commission (NRC) staff plans to issue amendments to Vogtle Electric Generating Station, Unit 1 and 2 (Vogtle 1 and 2) at end of May 2019.
By application dated December 19, 2019 (Agencywide Documents Access and Management System (ADAMS)
Accession No. ML18353B056), Southern Nuclear Operating Company, Inc. (SNC, the licensee), requested changes to the Technical Specifications (TSs) for the Vogtle 1 and 2.
The requested changes adopt Technical Specification Task Force (TSTF) Traveler, TSTF-412, Revision 3, Provide Actions for One Steam Supply to the Turbine Driven [auxiliary feedwater] AFW/EFW [emergency feedwater] Pump Inoperable. The NRC approval of these changes was announced in the Federal Register on July 17, 2007 (72 FR 39089). The requested change would establish a Completion Time for the Condition where one steam supply to the turbine-driven AFW pump is inoperable concurrent with an inoperable motor-driven AFW train and establish specific Conditions and Required Actions: (1) When two motor-driven AFW trains are inoperable at the same time and; (2) when the turbine-driven AFW train is inoperable either (a) due solely to one inoperable steam supply, or (b) due to reasons other than one inoperable steam supply. These changes were described in a Notice of Availability published in the Federal Register on July 17, 2007 (72 FR 39089).
By letter dated August 8, 2017 (ADAMS Accession No. ML15127A669), the NRC issued Amendment Nos. 188 and 171 to Vogtle 1 and 2 that modified the TSs to permit use of Risk-Informed Completion Times (RICTs).
SNC is not proposing any changes to the previously approved RICTs.
If the State of Georgia has comments, please provide the comments by April 30, 2019.
Thanks.
John
Hearing Identifier:
NRR_DMPS Email Number:
895 Mail Envelope Properties (BL0PR0901MB3731DCC829961605F1448AA1FA550)
Subject:
For Your Comments - State of Georgia - Vogtle Turbine-Driven Auxiliary Feedwater Pump License Amendment Request Sent Date:
4/1/2019 10:29:13 AM Received Date:
4/1/2019 10:28:00 AM From:
Lamb, John Created By:
John.Lamb@nrc.gov Recipients:
"richard.dunn@dnr.ga.gov" <richard.dunn@dnr.ga.gov>
Tracking Status: None "barty.simonton@dnr.ga.gov" <barty.simonton@dnr.ga.gov>
Tracking Status: None "jeff.morrison@gema.ga.gov" <jeff.morrison@gema.ga.gov>
Tracking Status: None Post Office:
BL0PR0901MB3731.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1823 4/1/2019 10:28:00 AM LTR 19-2018.pdf 7727137 Options Priority:
High Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: