ML19067A100

From kanterella
Jump to navigation Jump to search
4 to Updated Final Safety Analysis Report, Reference Drawings 158 - 284 (Redacted)
ML19067A100
Person / Time
Site: Crane 
Issue date: 04/06/2018
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Poole J, NRR/DORL/LPLI, 301-415-2048
References
TMI-18-047
Download: ML19067A100 (127)


Text

{{#Wiki_filter:8 7 6 5 4 3 2 REVISIONS 10 IC-2.3.41 REVISED TO INCORPORATE ECR-06-00143 REV. 1 H H if ) I Y' ~ 12~6A ~'I----- G 10 PS ,19A-3, ~*LO-V1J6A PS ,19A- ~-VI094-1 ~-VI094-2 ~-Vl094-3 PS 19A-l ~!~~~ ,,;;, Gf' @0-TO TURNING GEAR INTERLOCK '{' I Y s

  • IS*

7A 8A ~ fFE"\\_ e 'r ~.- r@@ ---111----'1 (FE\\ er---= r S . ~ 12A I~ ~*-" ~ H,P. Oil L.P. OIL TO TURBINE TO TURBINE HYDRAULIC HYDRAULIC CONTROLS CONTROLS t t G F EMERGENCY OIL PUMP LO-P-9A )1\\

@)-----l 116 1 4 6 1 I' SV~6 D c E 1 VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATABASE. 4. ALL ITEMS MARKED WITH AN (*) DENOTE THE INSTRUMENT IS DESIGNATED IN THE CREL AS "F'#" SYSTEM OTHER DEVlCES ARE DESIGNATED AS "LO" SYSTEM

5. (H) DESIGNATES GE ASSIGNED NUMBERS.

NOTES ~o N Cod tile Nome: 302280 $1 RIO I~ OJo K TE 589 (TC-4)

~ 1 I

GY-r TE 290 ~ TE 289 ~ ~ DUAL OIL FILTER AlB ~

LO~V101A lJ,

~0_Vl~43A I" LO-F-2A/B 3/4" (ii\\ __ I ~ TRANSFER VALVE A/A I LO-V98A 1 LO~V100A VENT ~ TS (OT-3) 579 1/2" 00 LO-V142A t~';c;;I' 3/4" AlB VENT 1-----@ LO-C-1 AlB TRANSFER VALVE I j~' l~

  • T

__ ~ II rDeS\\ III I ~ VENT n..u A/A I LO-V97A ~I LO-C-1A/A I 1/2" 00 3/4" J 4" [ F LO-V140A LO-V99A LO-V141A LO-V145A u

    • h\\*

(DT-2)~

    • ( *

(TC-2),;i5

  • TI;~

@*{>SJ TE 586 (TC~1J) (F~~NT STANDARD .. BRG) COT-4)@-- DUAL OIL COOLER SV-5 ~ OIL RESERVOIR TANK LO-T-2A ~1(FE\\ 9 T~


jlJ----

JI\\:" LO-V92A AUXILIARY OIL PUMP LO-P-8A LO-V91A 5V-4 lO-V93A 1 I~ I ~ LO-V96A ~ (PRV-J) ** LO-V138A LO-V135A (MRV-2) SEE NOTE :3 11** y LO-V95A lO-V94A I cb =~ PS 5A 6 D B c E 10 302*280 DRIVE TURBINE LUBE OIL FEED PUMP TURBINE "A" IA FLOW DIAGRAM THIS IS A COMPUTER ~~~E~~~~DE ~;~~~~A~~yl AmerGen SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM COMPONENT & SYS 10 INDEX 302-002 302-003 302-001 I I A 8 7 6 5 4 3 2

B t L.C-\\194B 8 7 t O!I. ~I-'-:Vf-' LG-P---8P 6 6 H F 1 /~' A 5 4 2

4 H H G G er. * \\', ~>-- D r;:l D II-f(;l

  • II j

I j ~ = c c I. 18 t* ~co- "OC>

  • u*

I l V1~UI r11 ~*"" l n 111 ALJ.i... *,l,.. ( '-\\tP' I p '8 Exelon. DRIVE TU~BINE L_LIBE Oil

8 7 6 5 4 3 2 REVISIONS DESCRIPTION R£IIISED 10 INCORPOI<ATE ECO-C3C60% H H FROM CONDENSATE BOOSTER PUMP DISCHARGE c o G F E VALVE POSITIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERwISE NOTED. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONU. ACTUAL OAT A CONTROLLED BY GMS2. OTES E, 'o'IE,425.21,1001,001-,230' S A C().IPUTE~ Gr£RATED OWG, 00 NOT REVISE IT MANUALLY 2


11~

OD Ii ~ CO-"1215 N n CO-V1219 PI PI 1399 T _ X. _X _ T '"0 00""6""" oo..~""," cs ~~ ~ ~ DPI ~'V '67 268 CO-CO-2" VI218 VI222 n _ og! I n ~ I I ~ MAIN FW PlW IQ 0 -- JJDDI IcrOO_ N I MAIN FW PUMP I I 111 IJ jj 01 FW-P-IA 100 FW-P-IB III D Dol 100 2 3 I I ~ ~ ~ 603'>' 602.0. 6036 6028 2-2- CO-'I275A 2-2- CO-1/2756 CO-V1216 2-2" CO-V1220 PI CO-V1217 CO-"1221 tio 269 "'~; ~'" 'f '1" .2 1/2" 21/2" PC CO-vI02"" CO-v277" 2 1/2" .2 112" CO-V2776 CO-v1028 PC PI 271 272 1287 PI 1286 2-2- CO-V! \\736 2 1/2' 21/2" CO-VI 173.... C ~ CO-V2768 ~ 23 TO CO-Y27811 2-2- TO CO-\\l2786 302-101 (A-A} 302-101 (8-.11 ~~ ~~ CAD FI THIS] I F G E o B c A '"23 302-281

SCALE, TM!

UNIT I DATE DATE lWEI -;§' Il4" FEED PIP SHAFT SEALS ~ LEAKCFF ~ /? /~.l'I,.O;;E FLOW DIAGRAM


om-I I~

/ GAl UCL.AII 12/11/97 COMPONENT", SYS 10 INDEX SYMBOLS INSTRUMENTATION SYMB(LS FLOW DIAGRAM 302-003 302-002 ~ A 8 7 6 5 4 3 2

'H JG I I I !F I I I I I I 'E I jo I I c B IA 8 I 7 I 6 I 5 4 I 3 I 2 I 1 I VENT 1/4" 1/2" FO-V69 OPI 763 FO-V39 11/2" FO-V40 11/2" RECIRC TO PUMP MECH SEAL 1/4" VENT FO-V6B 1/4" 1/4" \\ OSE CONNECTION 4" FO-V38 FO-V41 6" FO-S-1AIB TRUCK UNLOADING STRAINERS TRUCK UNLOADING STATION .y<<y~~ >S'~),(~- TO UNIT-1 EMERGENCY DIESa GEN 4" ro UNIT-1 EMERGENCY DIESEL GEN DAY TANK DAY TANK DF-1-28 AND PUMPS Df-P-1C &: 1D v I >m J.': ":ll >~ J_LO ~~I .., "I JS J_ITT Iv ~~ FO-V42 TO UNIT-I EMERCENCY DIESEL GEN DAY TANK DF-T-2A AND PUMPS DF-P-1A &: 18 L----§---0 FO-V46 CATCH BASIN 8" 4" .,I... ~~ ml7 ~~ ml7 ~~ ~~ 1" VENT 1600 GALLON ~ Ill S-1 FO-V72 7 OILIWATERSEPARATOR 2" 2" ~ ~ ~w/, 2 112* DIKE 8 DF-V23As FILL 3" VENT f""j1 I ~-- 2" I I~ UNIT 1 DIESEL GEN FUEL STORAGE 30,000 GAL DF-T-1 ~F-V238 YARD DRAIN 2 1/2" 1 1/2" FO-V1000 4" 3H FO-V3 ~ I t--01/4" ~, VENT FIELD 1 FO-S-3A/B AUX BOILER FUEL OIL STRAINER B&W N I e, ~ U1 ~ 3" HAND EMER. 1" PUMP VENT VENT FILL FO-T-5 FIRE TRAINING FACILITY FUEL OIL (CAP. 285 GAL) 7 1 1/2" FO-P-18 AUX BOILER FUEL OIL TRANSFER PUMPS 6 4" \\IE~~Rrs~t,~ME / ¥-- 1 "1 I LO ~ L-~ ~' ~ ~HI I--"' I I I G-l I I I 200,000 GAL NO 2 FUEL OIL STORAGE TANK FO-T-2 1" FO-V11A FO-V81 SEE NOTE 3 1 1/2" FO-V15 1 1/2" FO-V9A FO-V10A 2" FO-V14 FO-V29 1" 1" FO-V11B t 1/2" FO-V98 FQ-V108 2" 5 6" ? 1/2" FO-S-2A/B FUEL OIL TRANSFER STRAINER START r--~ t OFF STOP START r-~ i$- OFF I F- \\ OFF \\ I FO-V51B 3" FUEL OIL TRANSFER PUMPS (2)-1003 CAPACITY 75 GPM I I I FO-P-3A FO-V53A FO-V48 1/2" TO & FROM FS-P-3 3" TRAILER FlLL r.i 2" FO-V67 ~~"/,'.' FO-V20 1 1/2" HOSE CONNECTION (FROM FX-T-2 & FX-T-3) {5EEP02 361 SH. 1~C-2,3) 1/4" FO-V1006 LJ FUEL O\\L SAMPLING 30' 2* 11;2* I - 1* ~ FO-V16A 1" c '1 2 FO-V1003 1 1/2" FC FO-V168 ~ FO-V.308 NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

18fFO-V36B f,~-V35B

3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.

4 FAI FO-V55 3" SF OFF ~ FO-P-2 RAIL/TRUCK UNLOADING STATION VENT FO-V76 FO-V78 FO-V79 1/2" TO & FROM FS-P-1 SPILL CONTAINMENT 3" TRAILER FILL Cl VENT REVISIONS REV I ZONE I DESCRIPTION 30 D-5 ~~~l~~gTI~i [~~0~b8~~1~EL ~~J8~ 1 ~~;m~: 1 ~R~t~i~a8Js10N NOTE SHOULD REF. 302361 SH. 1 INSTEAD OF 302151 SH. 1. REF. AR 02591566. H 4" VENT ~--, I 0-1: I ~---j I I I FO-V58 3" FO-V71 2 1/2" 0 ..,........-ABANDONED PIPING FO-V33A1 114.. TO 3~~~~E5t~~~g1A FO-V34A FO-V71A 1 1/4" TO VALVE AS-V177A 302-051 (F-2) TO VALVE AS-V159A 302-051 (F-3) FUEL OIL TANK 50,000 GAL FO-T-1 ~I-HI ~-1 4" I I I I OVERFLOW 4*. G F E D c Pl-J FO-V1005 FO-V718 1/2." TO 3~~~~sts;~~~9B 502 1/2." 3 .302-003 302-002 302-001 DWG. NO. .1 1/4" FO-V328 COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM TITLE REFERENCES 1 1/4" FO-V348 TO VALVE AS-V181B 302-051 (F-1 TO VALVE AS-V1778 302-051 (F-2 ~I 0 ')' I Cod Fiie Nome : 302283__R30 I ~ 2 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear FUEL OIL UNLOADING STATIONS TO STORAGE TANKS FLOW DIAGRAM SHEET IREV. TMM 302-283 N/A 130 SCALE: NONE U1 ~ ~ A

F 8 o.s. BLDG. l.S. BLDG. 7 EXHAUST MUFFLER EG-XJ-51 4., 150-1 VENT4 4" l~~__J_ 6 "U.P.S," DIESEL GENERATOR EG-Y-2 f.l (i 1/4" ~ EMERGENCY VENT (OUTER TANK) I EMERGENCY VENT (INNER TANK) VENT FROM FO-V61 2.. ~~ 1" DF-VBS 2" 1/2" DF-V86 ~ 4* 14" l2E=.I::1J (500 GAL.) 1/4" 1"(150-1) 1"(150-1) F \\ DF-F-1 DF-V87 DF-VB4 5 2 --1 4 3 ABOVEGROUND (LS.BLDG.) INSULATED FLANGES~ I T T ~~ --1 '!il'1 2" I 1 REVISIONS REV I ZONE DESCRIPTION 8 IYARIESI REVISED TO INCORPORATE ECR-13-00255 REV. 1 H G F 'E ABOVEGROUNDt-150-1 UNDERGROUND ,-:;~,;<'~;:;%;<'~;:;;;;:;:;~"'~------------------------------------------_J 150-3 "<,,~~<.(/." "U.P.S.

  • DIESEL FUEL OIL STORAGE TANK (1000 GAL.)

DF-T-3 E D c BI Al L 8 o.s. BLDG. 1.5. BLDG. VENT LI 1HJBA SUBSTATION DIESEL FUEL OIL STORAGE TANK (275 GAL.) DF-T-5A OF-V35A~ 3/B" 00 1/2"~ 1/2" 3/B" OD ABOVEGROUND UNDERGROUND I 1 1/2" 7 TRUCK FILL CONN. 1 1/2" o.s. BLDG. LS. BLDG. 1 1/2 VENT o.s. BLDG. 1 1/4" SUB ST A llON DIESEL FUEL OIL STORAGE TANK (275 GAL.) DF-T-58 l OF-V35B 3/8" OD ~F 1/2" 3/8" OD C-1 150-1 --1/2" 1/2" 6 3/8"0D L_ I C-1 --1 T 150-1 LE 1111A 150-1 SUB-STATION DIESEL FUEL OIL TRANSFER PUMPS SUBSTATION DIESEL FUEL OIL DAY TANK (20 GAL.) DF-V78A DF-T-6A 230KV SUBSTATION EMERGENCY DIESEL "A" EG-Y-3A q 150-1 I C-1 3/8" OD VENT 1" l.S. EG-XJ-52A BLD~ EXHAUST MUFFLER o.s. BLOG. l.S. BLDG. O.S.BLDG. I 3 112" I... VENT 1/2" DF-Y3BA y 5 4 3/8"0D ~ 150-1 3/8" 3/8" DF-V368 Sl 3/8" I I I I DF-P-38 I 3/8"0D I VENT 1" r.s. ~DG. 3/8" C1 3/8" SUBSTATION DIESEL FUEL OIL DAY TANK (20 GAL.) DF-T-68 DF-V7BB 230KV SUBSTATION EMERGENCY DIESEL "B" EG-Y-38 ~T C-1 3/8" OD EXHAUST MUFFLER EG-XJ-528 3 1/2" 1/2" DF-V388 y 1/2" IE 11119 302-003 2 t 302-002 n 302-001 I I I I I I I I _J C-1 t-150-1 3/8" OD ABOVEGROUND UNDERGROUND COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM NO. DWG. NO. TillE REFERENCES 3 NOTES

1. VALVE POSITIONS SHO'M-1 FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

D c Cl ~I pi 0 N \\ Cad FUe Nome : 302284 RS l I~ 2 THIS IS A COMPUTER GENERATED DRAWING DO NOT RE'vlSE IT MANUALLY ExeJU~.r:!* DIESEL FUEL OIL FLOW DIAGRAM "UPS" DIESEL GENERATOR &SUBSTATION DIESELA&B TMl-1 I 302-284 Sc.t.LE: NONE z > A SHEET IREV. N/A 8

2" I 1---1__1 D-I I I LO-Vo08 1 I I ~** SHEET I"'* N/A 19 302-291 LO-V33A 2" SCI.lE: N1A RETURN LO-S-3 1:;0- '/2" lO-V55A fl?\\ ~ fl?\\ ~ ~~AJ:~Ac :hJ LO-V6B 2" ) 2" LO-V52 Y THREADED CAP fOR TANK TRUCK CONN'S n ~LO-V69 2" 15,000 GAL. TURBINE OIL STORAGE TANK LO-T-l LO-Vl0A OIL RESERVOIR FEED PUMP TURBINE A LO-T-2A I LO-V50A LO-V66A '/2" D 0/8" ~ ~ SAMPLE ~ET 0" -I ~),,":.tt-INTERFACINC CQNaJRRENCE I REVISIONS REV ZONE: DESCRIPTION 19 ARIES REV1SEO TO INCORPORATE ECR-06-00941 REV. a '/2" fcS0--a'" r I -"1'58 LO-V48A 2 ""t-J NORMAL LEVEL. =:J HEATER LO-C-3B 4" ~ 2" TIn.E 0" COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 4" SAMPLE owe. NO. 302-003 302-002 302-001 NO. 3 RETURN LO-S-2 1:;0- '/2" LO-V55B (lS\\ "@) (lS\\ \\tW r I I I I I I I I I H : I,, I I I I I G ! I I I I I I I I I E I I I I I I I I I I I I D i I I I I I I I I I I I C I I I I I I I I I 11 9 I I LO-V134 ~ ! ~ I ~ Cod FUe Name :302291 19 "/2" LO-V34 Y, f-;;;

t THIS IS A COMPUTER Z

~~E=~~~~ ~fAM~~~A~~Y AmerGen ~ ,\\f~g,:,:U~it. MAR 1l'11<OSKIE 11 0706 TURBINE LUBE OIL I-A FILTER PUMP ~-"***",,,, PURIFICATION & TRANS. SYS. -I~ FLOW DIAGRAM I I I I I I I I I L_.-J 6" LO-V50B LO-VSSB '/2" D 0/8" ~ 0" LO-V10B OIL RESERVOIR fEED PUMP TURBINE B LO-T-2B 1"T~2"-- LO-V9 SEE NOTt 0 I [ UNOERGROUND I X LO-V53 0" I] I I <:::: INSULATtO S" LO-V57 ~ GP150-1 FLANGES "l:!MAL LEVEL LO-V8 LO-L-2 FEED PUMP TURBINE OIL CONDITIONER LO-T-6 LUBE OIL SEAL DRAIN TANK 1/2" ~ LO-V29 ~-V488 I ~ LO-V43 1-LO-V38 \\-Y 1 LC{-Vj-4 1M LO-V45 F LO-F-4 0/8" 1" FEED PUMP 00 1" TURBINE OIL 1/2-LO-V46 \\ TUIFILTER LO-V39 \\..- LO-V47 SEE NOTE 3 LO-V37 2" rf? fEED PUMP TURBINE OIL EXHAUSTER ~8 ~ LS 220 ~:~, " 4 2" 4" 4" 1:" 0" 2" '1 2" 2" ~ 2" I LO~'42 8" 8" VENT TO ATMOSPHERE '/4" ¢ PI 007 NOTES 0" LO-V25 2" 5 ~ \\ 10/8" LO-V1 055 :t".. LO-V_1.907

1. VALVE POSIllONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2. ALL INSTRUMENT TAG NUMBERS ARE PREfiXED BY SYSTEM DESIGNATOR UNLESS OTHERWlSE NOTED. ~ 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND 19 TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT __ DATA BASE """l

4. RELIEF VALVE IS INTERNAL TO PUMP CASING.

0" -v-L I--- FS '57 0" LO-V6y ~ ...1191 2" LO-V12 i'J- ~ (fu) SAMPLE LO-V20 6 6" OIL fiLTER PUMP LS 111A 0" ~T LO-V1 4" fl?\\ \\:2V If---ll 4".* 2" LO-V24 ~ 2" SEE NOTE 3 LO-V23 2 LO-V16 3/4" LO-V14 2" /LO-V65 1." 4" LO-V11 2" MAIN TURBINE LO-T-5 LUBE OIL SEAL DRAIN TANK I' '/2"

r' 008

£ L~-V~5 2" LO-V19 0/4" Y Y -y T J RETURN SUMP L.J L.J LUBE OIL COOLER SHELL SIDE DRAINS 7 L MAIN TURBINE OIL RESERVOIR EXHAUSTER LO-E-3 CE, LI MAIN TURBINE (l1L1~ 1 [ OIL RESERVOIR ~ OVERFLOW "'i>(/o-C~-- LO-T-3 I FI LO-V67 r-.... 3/B" -t MAIN TURBINE OIL CONDITIONER EXHAUSTER LO-El ~ ~ LS 2'9 8 INTERNAL RETURN SUMP DRAIN ~ I~~S~ 2'8 OL ~ ~ LO-L-l MAIN TURBINE OIL CONDITIONER ROOF 8 I'D 0" 10"-'0.1.00_ r I L~- FILLl] LO-VOO 2" .-l ~ MAIN TURBINE OIL RESERVOIR OIL MIST ELIMINATOR LO-F-l I 8" 8"1 0/4" LUBE OIL SEAL DRAIN TANK LO-T-4 , '/2" 8 A H G D E c

F REffRENCES 8

7 6 5 4 3 2

1-----

  • ~*-~,--

'H I I IG I I I !F I I 'E I I I I iD le B IA I I I TURBINE END 8 1/2" (2) '2~, HG-V-G22A 1/2'" 1/2" 1/2" 1/2" HG-Y-1 CONDENSATE 1 /2" I ___1___,-1, DRAIN POT HG-Y-2 CONDENSATE DRAIN POT 7 6 5 REF. VOLUME CHAMBER GENERA TOR CASING TG-GN-1 H2 DISTRIBUTION PIPE TG-GN-2 2" 2" 1/2" 1/2" 1/2" 2" 2" 1/2" HG-V-220 ~ -yLEC~YER PIPE ASSY. I HG-V-225 rhHG-F-2 I y HG-V-224 1---@ TO H2 FLOW MONITOR ~ 2" 1/2" RELIEF VALVE TO VENT HG-V-G11 HG-V-G14A 1/2" HG-V-G14 1/2" 1/2" H2 & PURGING CONTROL STATION 3" VENT HG-Y-3 4 3 ,--------------1 ~'I ~I i I HG-V-G102

  • 1 i

HG-V-G100 COLLECTION CHAMBER HG-V-G101 I I HG-MN-1 PYROLYSATE COLLECTOR CABINET 2 REVISIONS REV I ZONE I DESCRIPTION 24 IVARIESIREVISED TO (1) INCORPORATE ECR-13-00410 REV. 0 AND (2) TO INCORPORATE AN ADMINISTRATIVE CHANGE BY ADDING LINE SIZES. HG-Pl 11790 1/2" 1/2" HIS DWG {E-6 1/2" HG-V-216 HG-V-217 1/2" HG-V-215 HG-V-219 HG-V-216 ~ W_~ D "-:J ~---J Cl Pl HG-V-,213 1789 1/2" HG-V-214 1/2" HG-V-212 HG-V-210 1HG-V-208 I 1/2" 1/2" I /'-----~ t :t 3" 1 1/2" HG-V-G30 HG-V204 L ______________ _J INSIDE TURBINE BLDG r- ---- ---- ---- ---- -- ~- ---- --OurS1DEWRslNE BLDG PG-T-1 C02 STORAGE UNIT r.i 11/2" r PG-V74 1 1/2" ITHIS OWG (E-5 PG-V75 1" ---~'"~(]VENT TO ATMOSPHERE SEE NOTE 3 I 111>4 1 1/ 2" (jFILL CONNECTION PG-V77 1/2" 11" PG-\\/76 PG-V78 1,, PG-V80 L_ ______________ _ -1 1/2" PG-V79 I HG-Fl I I 134 I I HG-Fl I I 1347 I I I I I I I I I f HG-V-211 I I I I L _ _J L _ _j 1/2" I lHG-V-207 HG-V-209 1/2" HG-V-206 H2 CONTROL PANEL BY GE' PG-V86 l PG V84T l!/2" PG-V88 ~,.. I ~-w su~~~:T~--. 4 --------~ 4 _ _P~7-- ---*--1 PG-Z-1 1/2" INSIDE BUILDING OUTSIDE BUILDING TRUCK FILL POINT HG-V20 HG-V22 HG-V19A FILL HOUSE PURGE/VENT HG-V198 HG-V2 r "c""'""

  • 1'-..,.. H, WITH

-~- L __ --------------

3" ENCASEMENT PIPE HG-V158 2"

GENERA TOR CASING (TOP VIEW) TURBINE END I I I I I I I

'c' :

'24'(1) COLLECTOR END NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERV'llSE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE
4. *= G.E. ASSIGNED INSTRUMENTATION DESIGNATION.
5. FOR PIPING BY AIR PRODUCTS INC. SEE THIER DWG.
  1. 89-3720.
6. FOR PIPING BY G.E. SEE THEIR DWG. #943 D. 894 7.(a) VALVE NUMBERS DESIGNATED AS HG-V-Gxxx, OR Sd-V-Gxxx ARE G.E. ASSIGNED NUMBERS (b) VALVE NUMBERS ASSIGNED BY OTHER THAN G.E. TO _

BE DESIGNATED AS HG-Vxxx, PG-Vxxx, OR SO-Vxxx H G IF E D c ~ ')' 'B' I I

  • I I

I I I I I I CadFileName:302301 R24

  • ~

HG-Pl-1703 I l~I l~I l~I I~ ~HG-1A6HG-2A

r HG-3A6 HG-5A HG-4A,b HG-6A 8

RUPTURE DISC___)' (TYP. 12 PLCS.) GAS STORAGE BANK #1 7 HG-Pl-1705 6 N ~ ""="HG-18,6,HG-28 fl ~ 'C"HG-38 6HG-5B,,bHG-48 GAS STORAGE BANK #2 5 ~ SEE NOTE 3 2" 4 HYDROGEN COOLERS (TYP.) 2" I I I I HG-V-G37F COMPONENT & SYS ID INDEX 302-002 SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM NO. TITLE REFERENCES 3 2 THIS IS A COMPUTER GENERA TED DRAWING DO NOT REVlSE IT MANUALLY Exelon. Nuclear 1 ;~.:;' '"""""" '"";,; 1 GENERATOR GAS & VENTS FLOW DIAGRAM PIPING TM1~1 302-301 N/A 124 SCALE:N/A z )> A

1---------- ---I 8 7 6 5 4 3 2 14 C-5 I R::V1SED TO INCORPORAE ECR-04-00576 REV 0 HI IH ACCUMULATORS A D e E 1 OF 3114 302-302 TURBINE EHC SYSTEM FLOW DIAGRAM G 1 VALVE POSITIONS SHOWN FOR REFEREJ\\CE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA, BASE. 4. SEE G.E.DWG.233R957 FOR HYDRAULIC FLOW ARRANGEMENT AT EACH MAIN TURBINE VALVE OPERATOR. 5. EHC-V~FV'1S FLOW CONTROL VALVE SUPPLIES fLUID FLOW TO FILTERS ONLY WHEN MAIN PUMPS ARE RUNNING EHC-P-2 MUST BE USED FOR FILTER FLOW IF MAIN PUMPS ARE SHUT DOWN. 6. ("')INDICATES G.E.ASSIGNED INSTRUMENT OR EQUIPMENT NUMBERS. 7. A. VALVE NUMBERS DESIGNATED EHC-V-FVOO ARE G.E ASSIG>.jED NUMBERS B. VALVE NUMB::RS ASSIGNED BY OTHER THAN G.E.TO BE DESIGNA ~ED EHc-vaa NOTES '"o lead File Heme' 302302 SLR14 I~.. !ii =.--'==..;...-=-t=-='.:.::=::....;:"'-'=='=--:--=-::-:-:=::-::--1~ EHC-E-1A "'HF-1 302~302 SHT.2(B~8 0-50 P5 G HYDRAULIC FLUID DRAIN TC 5 TO VALVE 5C-V26 S~E DWG 302-221 (D-3) l ~ 23-HF I ~ FROM FI~1328 3/8" 0.0 ~302 277 SHl9 (B-7) I 'LHF-PS2

HC~V~FV16B EHC-E-1B
  • HF-2 COOLING WATeR FOR CO\\lT SEE DWG.

302-221 (D-4) SC-C-2B 302-002 I SYMBOLS INSTRUMENTATION 302-003 I CDMPONEN":" & SYS ID INDEX I,:~ I 30:~~~~~ I SYMBOLS FLOW DIAGRAM EHC~V~FV4 SEE NOTE 3 L EHC-V-FV21 EFLG '" COOLING WATER FCR CONT. SEE DI'IG 302-221 (E-4) EHC-V-FV1 EHC--V-FV17 A5~g-~TAWT I TEST DUTTON VENT/ AIR DRYER EHC-T-2D EHC-T-2E EHC-T-2F @':r~'~' PS I I PS 102 103 EHC-V-FV9 EHC-V-F\\i10 EHC-V-FV47 EHC-P-1A AUTO START Cp) TEST BUTTON T EHC-V-FV8 EHC-V-i'V22 ~I ~ ~.~. ] SAMPLE ,~EHC~V-FV27 EHC~V~FV27!1 I ~ 989 EHC SYSTEM FLUID TANK EHC-T-l (400 GALLONS) EHC-V-FV5 EHC-V-FV6 SEE NOTE 3 SEE NOTE EHC-V-FV7 F I EHC-F-2A EHC-F-2B IF EHC-V-FV18 (Ps\\ ~ ~EHC-V-FV13A EHC-V-FV13 ~~ EHC-T-2A EHC-T-2B EHC-T-2C 1 FLG ~ 8f ~ EHC~V~FV26A EhC~V-FV26 PI ~ 988 Vf'J v,"'J-EHC-V-FV45 (S(( NOTE 5) EHC-V-FV46 EHC-V-FV25 SEE NOTE 3 TE 988 EHC-V-rV30 r;;\\ ~ 23-HT" EHC-V-FV33 EHC-V-FV42 EHC-P-2 EHC-V-FV32 EHC-V-FV31 ~ ~ SEC 1-------1'1. NOTE 3 FLUID FILLING CONNECTION TRANSFER FILTERING ~ 986 EHC-V-FV35

  • EHC-V-FV49 EHC-V-FV34 4

EHC-V-FV37 DISCHARGE PIPING IN THIS AREA WAS,RELOCATED TO DWG. 302-302 SHT. 3 OF 3 SAMPLING EHC-F-41 F EHC-F-3A EHC-V-FV48 ~'WL. I EHC-V-~V36 ~~t--V" SELECTOR VALVE POSITIONS

1. ALL PORTS CLOSED 2

PORT 1 TO PORT 2

3. PORT 1 TO PORT 3
4. PORT 1 TO PORT 4 2

IA Ie I,, I,, I,, 1 8 I,, I,, I I,, I,, I, iD !F I,, I,, I,, I, 'EI !G I I,, \\ 8 I 7 I 6 I 5 4 I 3 I 2 I 1 L --l

6 5 4 3 2 ZONE E>ESCl'IPTlON ARIES REVlSED TO INCORPORATE ECR-04-00269 REV 3 H RETS


~

ffi I E ~ ~I F D e ~ SHEET I'~ 2 Of:3 4 J> )Do- ~~ ~ 302*302 SCA~ 11~'3--t51 TMI*1

302J02_S2Y14 1.- REFERENCE GE OWG #233R957 REY.12 G

OIL OR HYDRAULIC fLUID LINE ELECTRICAL CONNECTION ELECTRICAL (DUAL OR MULTIPLE LEAD) STEAM LINE 225 PSIG MAIN PUMP DISCH,OIL 2S PSIG BEARING HEADER OIL 1600 PSIG HYDRAULIC FLUID TO OPERATING DEVICES (FAS) 1600 PSIG INTERNAL HYDRAULIC FLUID TO JETS OF SERVO FROM f AS 1600-0 PSIG HYDRAULIC FlUID TRIP SYSTEM.(ElS) 0-50 PSIG HYDRAULIC FLUID DRAIN (FCD) 1600-0 PSIG RELAYED HYDRAULIC FLUID TRIP SYSTEM (RETS) OPERAnNG SIGNAL FROM ELECTRO-HYDRAULIC CONTROL CABINET. FEEDBACK SIGNAL TO ELECTRO-HYDRAULIC CONTROL CABINET, LEGEND: INTERfACING CONCURRENCE THIS IS A COMPUTER ~;~E~~~~ ~:~~~~A~~AAmerGen wo Z; ICad fill! Naml! R I 18 NOTES: TURBINE EHC SYSTEM I~ 11/;;::1 lo~;LOWDIAGRAM IA 2 TIm lev 1-"-;:';"-fQ9:i-"':" J~ 3 RETS I I FCD I I I FAS I I I I 5 I 4 2" 1 1/2" 2" 2" 1 1/2~ 1 1/2~ FAS FAS FCD FCD 1 1/2" FAS I REFER TO SH 3 3~-----t4\\ C c.,"'V~ ~ ll":...__ I I 0 I I I I I '-I ~ FAS FCD 1 I 2" ~I~ ~I~I~I~I~ (WEST SIDE) H.P. TURBINE FRONT STANDARD REFER TO 302-302 SH.3 OF 3 EMER&~Crv~~p8\\AlVES PJ TO fLUID COOLERS E F iD 8 1 7 1 6 L IA I,, I Ie I I,, I,, 18 I,, I, I

8 7 6 5 4 3 2 F c D A "i E H ~ ~ J> )In>~ ~


?-

SIZE


(X.XXX) 302-302 i 3 OF 31 6 TURBINE EHe SYSTEM FLOW DIAGRAM 1.

VALVE POSITIONS SHOWN FOR REFERENCE ONLY, ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED 3 SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE

ONLY, ACTUAL DATA CONTROLLED BY GMS2 4.

REFERENCE GE DWG #233R957 REV.12

5. c:=J

= DEVICE NUMBERS ASSIGNED BY GENERAL ELECTRIC. OIL DR HYDRAULIC FLUID LINE ELECTRICAL CONNECTION ELECTRICAL (DUAL OR MULTIPLE LEAD) STEAM LINE 225 PSIG MAIN PUMP DISCH.OIL 25 PSIG BEARING HEADER OIL 1600 PSIG HYDRAULIC FLUID TO OPERATING DEVICES (FAS) 1600-0 PSIG HYDRAULIC FLUID TRIP SYSTEM.(ETS) 0-50 PSIG HYDRAULIC FLUID DRAIN (TSO) OPERATING SIGNAL FROM ELECTRO-HYDRAULIC CONTROL CABINET. FEEDBACK SIGNAL TO ELECTRO-HYDRAULIC CONTROL CABINET, FLOW RESTRICTING ORIFICE REVISIONS LEGEND REV ZO~E DESCRIPTION 6 E-5 REVISED TO INCORP. ECO-C306276 INTERFACING CONCURRENCE IsANa. THIS IS A COMPUTER I~ __ GENERATED DRAWING DO \\ GPU NOT REVISE IT MANUALLY NUCL.AIf ICAI REFERENCES r il TG-KT-1O,12,1' !1SV1,4,Hl-1 owe., NO TG-KT-1,3,4 SV1,2,3,4-LT1 CONTROL VALVES TG-CV-1,2,3,4 LNa N ~COd F~e Nome; 302302 S3 R6==:==J I~ I a N FROM (F-6 COMBINED INTERMEDIATE VALVES (TYP. CIV-2,4,6) INTERMEDIATE STOP VALVE TG-ISV-2,4,6 'FAST-ACTING VALVE STEAM FROM MAIN STOP VALVES ~ SH.2 FROM (F-6) (0.0"') SH.2 i 'FAST-ACTING TG-CV-.1,2,3,4-S0V VALVE ~ SY2~ ~ 'SHUT-OFF

VALVE MAIN STOP VALVES (TYP, TG-SV-1,3,4) INTERCEPT CONTROL VALVE TG-ICV-2.4,6 MAIN STOP VALVE TG-SV-2 TG-KT-5,6,7,8-A I CV1,2,3,4-LT1 SERVO VALVE f-----------------------------------------------I' NOTES TG-KT-9,l1,13 EMERGENCY TRIP VALVES (IN FRONT STANDARD) ---) TO REACTOR PROTECTION ~ ~ ~ SYSTEM (ANTICIPATORY TRIP) LUBE Oil FROM 302-305 (D-7) ""SHUT-OFF VALVE INTERMEDIATE STOP VALVE TG-ISV-1,3,5 EHC-V-0064 I ~ rp (PS ~926 f----{::j(J----:,~ I~ 'I' fPS ~925 .------J>I<I---:2~ .L_----'(E:.:T.:::S):...- --'r------~ L_--\\J02-302 SH.2(F-8) >0~Le~~TROLLING 'TEST VALVE 302-302 SH.2(F-8) 302-302 SH.2(f-8) I Solenoid Valve I~'-',",) I>--1302-~2(F-8)>j~o~L~ALVES (TSD) INTERCEPT CONTROL VALVE TG-ICV-l,3,5 l I'l-~ ~ ~ (FTS) (FTS) COMBINED INTERMEDIATE VALVES (TYP. CIV - 1,3,5) 302-302 SH.2(F-S) COMPONENT GE TAG NUMBER GPUN TAG NUMBER MANUAL TRIP HANDLE MTH-SJ EHC-KS-OOOI POSITION SWITCH OIL RESETTING ORP-52 PISTON SWITCH EHe KS 0002 EMERGENCY TRIP ETS-PSJ SYSTEM SWITCH EHC-PS-0100A EMERGENCY TRIP ETS-PS4 EHC-PS-Ol00B SYSTEM SWiTCH MECHANICAL TRIP VALVE MTV-PS1 INDICATING PRESS.SINITCH EHC-PS 1701 SECONDARY SPOOL VALVE ETV-PS2 EHC-P$-1702 INDICATlNC PRESS.5W1TCH ELE~1i~~OI5<}~~~~S.~~~H AI ETSVNJJ1~ AI EHC- '1-0021 A/SWr TCH ELECT. TRIP SOLENOID VALVE BI ETS1{SEJJ~ 81 EHC-V-0021BISWITCH SO'-HWID PRESS,SWlTCH MECHA~bCs~~o~RI~J~cL~NOID7 MTS/MTSS EHC-MTS/SWITCH SOLENOID O~hLm!jSOLENO\\O OT~0S~£D6 LO-V-0104/S0l RESETTING SOLENOID ORRSSVO_V£05 LO-V-0105/S0L. OIL VALVE SOLENOID MECHANICAL TRIP MTV/MTVS EHC-V-0017ISWlTCH VALVE POSITION SWITCH Ms~I~~~\\g~~~2~~~U~~ff~1 MLV/MLV SD11 EHC-V-0018j':JJLjSWlTCH MLV S1 ELECTRICAL TRIP ASS Y ETV SECONDARY SPOOL VALVE EHC-V-0019 ELEi6~t%i~0~O~~~~STWI\\~~VEl ELV{LE~~s104 EJ-IC-V-()()20jSll..jS\\YITQJ ["M"fY=P3TI EHC-V-0069 A B E c D GI I ~~ ~ I 1 w I trl 'FAST-ACTING VALVE I IG F H 8 7 6 5 4 3 2

~-----------------------------------------------------------------------------------------------------------------------------------,

H IG F

E D c B lA 8 7 6 5 4 3 2 1 2 1/2"

  • HGA4(~H23 r"""Ci*:~-*'---~2;;." -------*

SO-V-H22 SEE NOTE 9 SO-V861 u SO-V-H46 SEE.NOTE 9 HYDROGEN FILLED GEN. TG-GN-1 HYDROGEN SHAFT SEALS. ,- 1--lYnRClr.FN nFT SO-V-H01~ 11 u SO-V-G33 1 SO-V-G33A VENT t AIR DETRAINING TANK SO-V-H06 ~ 1/2" I ~SO-V-H02 SO-V-G34 I... SO-V-G34A 1 1/2" ~

r t n SO-V-H05

~ 1 ~~ 2

  • HGA5 f----1114---J
  • SO-V-H24 3/4" -v PITCH 1-1/2" LIQUID DETECTOR LOCATED ON SEAL OIL UNIT

-I------------I---- ------------------------------ 3" 3" 1/2" SO-V-H07 1/2" L__ __ -RECIRcuLATION SPRAYS SEAL OIL VACUUM TANK SO-T-1 8 SO-V-H31 SO-V-HOS ... t.... l I I SO-V-H36T T SO-V-H30 ~ 1 J" SO-V-H20 SO-F-1 SO-V-H25 -4; SEAL OIL PRESSURE CONTROL VALVE SO-V-H264 1/2" 11/2" I I~ ~ 0 ~ ~ SO-V-H18 F 1/?i* HFI-1 SO-V-H83I SO-V-H19 SO-V-H21 7 2 1/2" SEAL OIL ALARM PANEL 63-P7 1107 SO-V-H82* SO-V-H35* 2 1/2" SO-V-H15 SO-V-H14' SO-V-H17 (SEE NOTE 3)

  • -.;...~

EMERGENCY SE~P GN P-2 3" 2 1/2"

  • ESOP SO-V-H12 (SEE NOTE 3) 8" 4"

SO-V-H34~ 1/2" ~ ~ RECIRCULATING SEAL OIL PUMP GN P 4 RSOP * ~3~~1 1;r t~ ~ 3" 4" 5" 6 5 4 MAIN SEAL OIL PUMP GN-P-1

  • MSOP 1 1/2" SO-V-H11 A

Jn~~ II 1 1/2" ~ II SO-V-H20-2 (SEE NOTE 8) VACUUM PUMP GN P 3 (SEE NOTE 5)

  • SOVP 3

~ T TO ~~ r1 SO-V-H39 SO-V-H4 ]/2" y CD~PONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM TITLE 2 REVISIONS REVISED TO INCORPORAE ECR-13-00300 REV. 0 NOTES:

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSillONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. SEE G.E. DWG. 949D100 FOR INSTRUMENT SET POINTS AND OPERATING INSTRUCTIONS.
5. VACUUM PUMP (GN-P-3} CASING TO BE BE DRAINED PRIOR TO STARTlNG.
6.
  • INDICATES G.E. ASSIGNED INSTRUMENT OR EQUIPMENT NUMBERS.
7. A. VALVE NUMBERS DESIGNATED SO-V-HOO ARE G.E. ASSIGNED NUMBERS.

B. VALVE NUMBERS ASSIGNED BY OTHER THAN G. E. TO BE DESIGNATED SO-V-00.

8. SO-V-H20-2 OPENS TO PROVIDE LUBE OIL WHEN MOTOR ENERGIZED.
9. SO-V-H22,46 DISCS ARE DRILLED TO PREVENT TIGHT SHUT OFF AND STARVING SEALS.

H G F E D c 0 I Cod File Nome :302303_R6 I~ THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear ~~~K 1E1KOSKIE* 08/29!.~'1 SHAFT SEALING SYSTEM FLOW DIAGRAM 302-303 SHEET I'" N/A 6 SCALE* NONE A L ___________________________________________________________________________________________________________________________________ _j

I

H

!G I I I I I ! F I I 'E I I [o I c I I I I !s I IA r 302-163 (D-1) DEMIN WATER ~ \\"" 0 I RESIN DRAIN 8 1/2" 63-P79M GSC-V-Y61 GSC-F2 ~SC-V-Y21 ,.,..,...~ V~NT 2" y 8 y 2 DEIONIZER YDE-1* GSC-K-1 SAMPLE YST-2* GSC-S-2 TO DATA LOGGER 7 GSC-V-Y55A J SPARE 1/2" GSC-V-Y64 Pl 1017 7 Pl 1018 2" ~ 1/2" GSC-V-Y19 2" 6 ~ 1/2" GSC-V-Y50 z ~ ~ J I zl ~ 2L£.__j : TURB ___ _j END GSC-V-Y51 5 3/16"¢ HOLES FOR FLOW RESTRCTION 2 1/2" 2 1/2" °;~ !CJ l_ "GSC-V-100 I 1/2" 4 GENERATOR FRAME COLL. END 3 TG-GN-2 EXCITER POWER RECTIFIER CABINETS EXCITER HOUSING 2 REVISIONS 2 IVARIESI REVISED TO INCORPORATE ECR-12-00316 REV. 0. NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

3 SEE G.E. CO. DWG 234R305 FOR INSTRUMENT SET POINTS AND OPERATING NOTES.

4. A. VALVE NUMBERS DESIGNATED GSC-V-YOO ARE G.E. ASSIGNED NUMBERS.

B. VALVE NUMBERS ASSIGNED BY OTHER THAN G.E. TO BE DESIGNATED GSC-V-00.

5.
  • DESIGNATES G.E. ASSIGNED INSTRUMENT OR EQUIPMENT NUMBERS.
6. ALL PIPING TO BE 304SS-MAGNETIC TYPE MATERIALS ARE NOT TO BE USED FOR ANY APPLICATION IN CONTACT WITH THE STATOR COOLING WATER.
7. FOR INSTRUMENT AIR SUPPLY TO VALVE GSC-V-Y63 SEE DWG 302-277 SHT.7.

H G F 1/2"~1/2" LI GSC-S-1 I 11" YST 1* I 11 lyl 5" 8" I 1 1/2" I I TO SLMS SAMPLE INLET IJ0230T"Si.J. 2 (G 7)) FROM SLMS SAMPLE OUTLET (.302304 SH. 2 (F 3)1 E 63-PBOB 6.3-P60A YGA-3 GSC-V-Y48 y 6 RESERVE PUMP AUTO START TEST BUTTON 20-95* y STATOR WATER COOLERS 5 5" 5" y 1/2" GSC-V-Y03 5" 4 1 1/2" GENERATOR STATOR COOLANT STORAGE TANK GSC-T-1 __ J LS 828

  • 63L65 Q!:EB_A~N~WJ:.RJ:E~EL 0*-~ccl----<

4" GN-P-5A y GENERATOR STATOR COOLANT PUMPS GN-P-58 y GSC-V-Y01

  • 63-T-72A
  • 63-T-728
  • 63-T-72C GSC-V-Y02 2"

v-v, I ~ 6"1 )'.: J B GSC-V1004 0 0 ~ 1" It" 1" ~ SPECTACLE FLANGE II 2" 11 1/2" GSC-V-YR38 GSC-V-Y31 1/4"0.D. 1/4" GSC-V-84 y DRAIN -rf1r--- IA-V2915 GSC-V-Y1B L ______ _ ~ 0 I STATOR WINDING v COOLING PUMP UNIT I 3/8" 0.0. t~~~N~t~]ON


'----<302304 SH. 218=-711 D

c 0 (,, 0 Cad File Name '3(52304 Sl R2 I.p. COMPONENT & SYS ID INDEX COMPUTER DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear GEN STATOR COOLANT FLOW DIAGRAM SHEET IREV, A SYMBOLS INSTRUMENTATION TMl*f 302-304 302-001 SYMBOLS FLOW DIAGRA~! SCALE: N!A TITI.E 3 2

~-----------------------------------------------------------------------------------------------------------------------------------, 8 I 7 I 6 I 5 4 I 3 I 2 I 1 H IG I I I I !F I I IE I I iD I I lc I I !s I I I I I lA 8 SAMPLE INLET 1302277 SH. 1 (E 1 1 /4" 00 GS-V1015 STATOR LEAK MONITORING SYSTEM PNL-1 GSC-V-1011 TEST GAS INLET t-0 1 , f wr 1 DEMIN WATER INSTR. AIR SUPPLY 02277 SH. 4 (A 6 SLMS INSTR. AIR RETURN 02304 SH. 1 7 1/2" 00 I L 6 L----- 3/8" O.D. lo~_j L PB C02 TEST PORT I ~~ ~-~ 3/8" D.O. GSC-V-1008 GSC-V-1009 GSC-V-1010 5 1/4 OD DRAIN PUMP GSC-P-1 GSC-V-1014 l_ 4 I I I _j 1/4" OD 3 SAMPLE RETURN 1302304 SH. 1 (E 1 302-002 302-001 DWG. NO. COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION TlTLE REFERENCES L ______________________________________________________________________________________________________ _ REV I ZONE I DESCRIPTION B-7 REV. TO INCORPORATE AN ADMINISTRATIVE REV. PER AR 01308771. CHANGED CONTINUATION FLAG COORDINATES FOUND AT B-7 FROM L-~--~-F-_3~To~c_-~1. __________________________________ -iH G F E NOTES

1. SEE SH. 1 FOR GENERAL NOTES.

D c ~ ~ ICadFileName:302304 52 R1 ~~ 2 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY _Exelon. Nuclear GEN STATOR COOLANT FLOW DIAGRAM 302-304 2 SCALE: N/A A

1-----------------------------------------------------------------------------------------------------------------------------------1 'H G E D c !B I,, I A 8 7 6 5 4 3 2 1

-----------------------------------------------[

I' SHAFT DRIVEN '-' 3/8' OIL PUMP FRONT STANDARD LO-Vl02 y FROM H.P. LIFT PUMP /f---------+------------------------i' If------------<< 302-306 (0-8) I LO-P-l0 LO-P-7A ..... ~ ~ ~~E~~~~~~[~~fp LO-V104 DEVICE VENT 2 1/2" .................... ~~...... ~ea~~ LO-S-6


------------------~:------------....

LD-Vl044 LO-Vl045 1~4r--{~~~.......... 8.".................... ~........................................................................ ~ 6" 302-306 (E-8) TO TURBINE BEARINGS TO H.P. LIFT PUMPS 302 306 Cc 8) f--- NORTH ENCLOSURE TO H,P. LIFT PUMPS 302 307 CC 8) f--- SOUTH ENCLOSURE 8 10" LO-V10.3 "'"'"'=-V'-'-,----,~ ~ I-----...J....--CU---'---{

  • LBO-PS61 lra~>h3-y,8,,*0.nD.n><J]------1

'---.J LO-Vl049 t IN ~ '-e./ TE 469 6" TI 1186 OIL COOLER I-~ - -. - -- A EMERGENCY BEARING __ LO-P-~ _ OIL PU~P t IN 10" SUCTION SCREEN I I I I I I,--------- t IN 8" LO-Vl053 f'~-! -----l I'" SCREENS/i I OIL RETURN I I SECTION 2" LO-Vll1 I I BOOSTER PUMP I LO-- T--3 MAIN TURBINE LUBEOiL RESERVOIR L ___________________________________________________________________________________ J 302-306 E-8 FROM H.P. LIFT PUMPS 302-306 (8-8) FROM H.P. LIFT PUMPS 302-307 (8-8) LO-V71 COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION SYM80LS FLOW DIAGRAM 7 6 5 4 3 2 NOTES REVlSIONS DESCRIPTlON REVISED TO INCORPORATE EeR-l0-00022 REV. a

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTI-lERWlSE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2.
4. SEE DWG. 302-291 FOR ADDITIONAL CONNECTIONS TO LO-T -3.
5. ALL ITEMS MARKED WITH AN ASTERISK (*) DENOTE THAT THE NUMBER WAS ASSIGNED BY GENERAL ELECTRIC.

pc~odLom",~No~m~'~:30~2M30~5~~8========l_.. ___________ ~ H G F E D c ~ lJ, ~, W I TI-lIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. z Nuclear ~----------+-------~--------------~ ~'-"""'''''-----!.'"~GENERATOR LUBE OIL SYSTEM MAIN TURBINE A FLOW DIAGRAM 302-305 N/A 8 SCALE: NfA L ___________________________________________________________________________________________________________________________________ ~

1-----------------------------------------------------------------------------------------------------------------------------------1 E Ie I I I 18 A 8 7 6 5 4 3 2 1 I T r I I I I I I I I T I ~-! I GENERATOR TG-GN-1 r I I I \\I-~T I I @--! I ~" 10 E,F-7 REVISED TO INCORPORATE ECR-10-00435 REV. 0 EXCITER TG-GN-2 f---'--------1 I I I H G ILO-S~17 I I I I I L __ LO-S-20 LO-S-22 J F 302-306 E-1 302-306 E-1) FROM OIL COOLER LO-C-2B 302-305 (E-8) LO-S-15 5" I . 6c\\ l~ I I I L ____ _ I I I --~ TO AIR DETRAINING TANK L 302_Sf03T(:_8)........ _rl--_.1 5" LO-V131 LO-S-18 TO AIR I I I L DETR~~~¥_~ANK........ __ --..J 302-303 (E-7) LEAK OFF L ________ L~K~~ _ ~E~O£.F ________ -.J ~---------------------------, LO-Y132 I I LEAK OFF ~ I I I I ~* _____ J I I 14-2 I I I L LJ OIL TIGHT COMPARTMENT ~ H.P. LIFT PUMPS - SOUTH ENCLOSURE --y-------------------------------------------------------------------------- TO LO-T-3

==3~of2~3~O~5j(QO~2~)J_----------1 8 7 6 5 4 <0. 3 302-003 302-002 302-001 COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATlON SYMBOLS FLOW DIAGRAM 2 5" 2 1/2" NOTES 302-303 8-6 TO SO-V-H41 BEARING OIL DRAIN 302-303 (0-8) FROM SO-T-4

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2.
4. ~~LE 1~~MSB~t~~EJ> A~~~GNAE~ ~~T~~~~R~J ~CENCo,.~C~AT
5. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.

Cad File Nome,302307Y10 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear E D e o W o... ~'-'=~--"L"'~GENERATOR LUBE OIL SYSTEM FLOW DIAGRAM A MAIN TURBINE SHEET REV. 302-307 N/A 10 SCALE: NONE L ___________________________________________________________________________________________________________________________________ ~

1--------------------------- 8 7 6 H TIJRB BLDG EL 322'-0" ~JSOW£(:;} ~ ~ POS CONDENSATE 2 1/2" 2" 2" 302 101 (A 3) FROM co-V227 \\.;.--J HS-V6 \\.;.--J 2" ~ "-=.) l~ 1262 l~ TG-U-1LPA I A EXHAUST HOOD I 3/4" 1/2" ~ 5 + lURa BLDG EL 355'-0" (UNDER lURB HOOD WALKWAY) I HS-V5 I ~ I I 3/4" I I 2 1/2" HS-V4 I I I' 1259 T 1263 T 1260 1~ TG-U-1LPB I B EXHAUST HOOD 1 4" HS Pl 1511 I

1/2" 3/4"

... ~ ,1/2" 3/4" r~ ~ 3""""t-. ~ ~ 3""""t-. 'E I I I Ie I B A 1" EX 3/8" EX-V-1130 36fj PT 00 I 1749A v+" I I EX 3/8" EX-V-1131 3/8" PT 00 00 I 1750A T ~'323/8" 1~1A 00 }--~ 1" I INST AIR 302 277 SH 4 8 4 FROM IA-V375 SIGNAL AIR TO HS-V6 POSITIONER THIS OWG. CG 6) 8 L ___________ _ 1 1" 1" 1" 1/2" C ,1/2" 1/2", 1/2" ~ ~ ~ 1/2", ,1/2" 1/2", 1/2" ~ ~ ~ ~ ... ~ ~"/2" 3/4" 3/4" 1/2" ~ ~ ,1/2" 3/4"

  • TCEH_r--,...a

-~ ~ J C--@----- - ~ 1 1/2" 1 1/2" 1 1/2" 1 1/2"

  • TCEH-4 C------

C--@----- ( --@- ~TO ALARM C--@--- I TO ALARM K-1-2 K-1-2 1 1/2" - 2" 3/8" 00 3/8" 00 ~TURBINE HOOD WALKWAY 3/8" 00 3/B H 00 ,,5" Y HS ,,5" 3/8" 00 PS I,,;- ,,5" 5" 1" 3/8" 00 3/8" I 00 I 3/8" 00 7 6 5 4 HS-S-l ~ 1" ~ 4 3 2 1/2"

1) 1261 I

TG-U-1LPC I C EXHAUST HOOD I 3/4" 1/2" ~ ,1/2" 3/4" r--C~~-. 1" 1/2" c ,1/2" J 1/2", 1/2" ~ ~ 3/4" 1/2" c ~"/2" 3/4" =-:- ~

  • TCEH-6 C--@--

1 1/2" 1 1/2" C------ ( --@- ---tr-- TO ALARM K-1-2 I-- 2 1/2" 3/8" 00 3/8" 00 2 2 1/2" DESCRIPllON REVISED TO INCORPORATE ECR-09-00092 REV 1 NOTES

1. VALVE POSIT IONS SHOWN FOR REFERENCE ONLY.

ACTUAL PO SITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRU MENT TAG NUMBERS ARE PREFIXED BY SYSTEM DE SIGNA TOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND LlCABLE ENGINEERING SET POINT DATA BASE.

iN THE APP

4. "'INDICATES GE TAG NUMBER.

H G F E D --~ n3/8" 00 3/8" 00 3/8" DO 1" 1-'- I EX-V-1138 3/8 H EX 00 PT V," 1749C I I EX-V-1139 3/8" I 00 EX:~40 3/8" I EX I /f" 00 PT 1751C PC~Od~Fde~NO~m~'='3~O~23~08~R8c=======1_ ______________________ ~ e o ~ a I 'l' ~ I Exelon. z ~~--------~~------~NU~C~I'~"------------------_i~ I ~~="---"'L~ EXHAUST HOOD SPRAY SYS FLOW DIAGRAM A MAIN TURBINE rc,--c3C:072--'O""0""3---'--CO-M-P-O-NE-N-T &5-YS--10-'-No-E-X. --J"(;,1{;'----------,,,riI---=r;;;;:---------;;;--;;;-:Srl 302-002 SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM REFERENCES 3 2


~

I I H G !F I I E iD le I I I !a I I IA I I I 3/4" 8 I 7 I 6 I 5 4 I 3 I 2 I 1 EG-V2A SEE NOTE 3 AIR EG-V12A EG-V10A '14" I RECEIVER ~EG-T-1A-1 EG-V11A y EG-V3A SEE NOTE 3 2 1/2" AIR EG-V12C EG-V10C .V*'~ RECEIVER ~EG-T-1A-2 ---~ 11/2" EG-V11C y 2 1/2" I ~ "'lw "'z ~ :J g 3/8" OD C-1 EG-V1006' 3/4" SUPPLIED WITH DIESEL GEN. <t ROOF OUTSIDE INSIDE SIF.O. 1 1/2" 3/4" EG-V15A I EG-S-7A EG-V16A EG-V55A EG-V185A DF-P-1A ~ DF-S-1A DF-V4A EG-V16C ~ LD DF-P-18 ---cocr DF-VBO SEE NOTE 3 EG-V17A DF-V6A 'i7oF-V68 1" 11" DF-V5A Z" 2* 5-115-111 FROM FM-313A 302-283 (F-7 1" I EM ERG. DIESEL GEN. 1 A 302-353 (F-7), EG-Y-1A s s m J ~ e ~ ~ J. J. g g g 1" 1" 1" z z ~ ~ w ~ ~ z 1i' ~ ~ ~ ~ w iil ~ ~ DAY TANK 550 GAL. DF-T-2A DF-V28A m e

ll

~ 1" z

1

[§ ~ e-,. ~ }.i L;J ~S 244A AC & DC 2448 TRANSFER L.._ ;T~~~.._J STOP CONTROL EMERG. DIESEL GEN. 18 © © I I 0,_ 0 ~ I g 1" 1 z e 11 z 0 w w N I~ ~ ~ ~ DAY TANK 550 GAL. DF-T-28 302-353 (F-3) EG-Y-18 e I 8 ~ I g ~ g 1" z ~ ii" w ~ ~ z ~ ~ ~ ~ !l: 5 w iil ~ [§ ~ $ I DF-V28B F.O. S EG-V168 EG-V17B EG-V16D ~ 48 LD EG-S-78 SUPPLIED WITH DIESEL GEN. KS AUC/B, EG-V158 ~ 1 1/2" DF-V81 SEE NOTE 3 111'1111 I DF-VB2 DF-P-1C DF-P-10 ~ (DC) DF-VBD 1" 1* 2" DF-S-18 FROM FM-3138 2" DF-VSB ~ 4 1t DF-V48 2* <O 2 1/2" 3/4" EG-V55B EG-V1858 1, B-7) 21 REV I ZONE I DESCRIPTION 21 I E-2 I §6~ 1~f8r1~i 1~~0~68§~1\\EL ~~g~i~~;rd~: 1~tR~76'ENi~iv1s10N NOTE SHOULD REF. 302361 SH. 1 INSTEAD OF 302161 SH. 1. REF. AR 02591566. EG-V128 y 2 1/2" EG-V12D 1/2"1 EG-V28 SEE NOTE 3 AIR RECEIVER ~G-V108 EG-T-18-1 3/4" / EG-V11B 3/4" EG-V38 SEE NOTE 3 AIR EG-V10D RECEIVER_2 13/4",

  • EG-T-18 ~

EG-V11D 3/8" OD ~ ~1~ )' ~ :J g EG-V1007' 3/4"1 EG-:-V18 SEE NOTE 3 H G F E D c MOTOR & ENGINE DRIVEN COMPRESSOR EG-P-1A -;\\I~' ~ ~ J.J~ ~J_ g o"


~'<<'

~~%w~~~,Q>-',,_S'._>,---------..,.~~-"";->";,~,, !+l~I ~ ,,~.,, o" MOTOR &. ENGINE DRIVEN COMPRESSOR EG-P-18 ~ 01 e::~ 8 7 6 NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFlXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. LINE SPEC:ABOVE GROUND 150-1 UNDERGROUND 150-3 EMBEDDED IN CONCRETE 150-1
5.
  • VALVES: EG-V1006 & EG-Vto07 ARE EQUIPPED WITH COLLARS THAT PREVENT CLOSING.

5 4 NO. 3 302-003 302-002 302-001 OWG. ND. 8:;;:; COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM TITLE REFERENCES p u 0 j Cod File Name : 3oi35LR21 I~ 2 u ~ I THIS IS A COMPUTER Ex I GENERATED DRA\\\\1NG DO e on. E NOT REVISE IT MANUALLY Nuclear )> EMERGENCY DIESEL GENERATOR SERVICES FLOW DIAGRAM TMl*1 302-351 ~1~1;1 SCALE: NONE A L------------------------------------------------------------------------------------------------------------------------

G A

    • I
  • I

!J'

~......

-~ --=-~r...

    • il.*

I\\.~- .. j : __..... ftlf....,, " u11 '"' ~.... --.. ----~-----~*'). I, ,,......_.I r..:..... ~...... ~... T .L I 1: I I '. ",:'I:.. -?v ~---...;..**** ~-... ~.~ ----~ ~

    • r:::

l~...;_JI

  • I 11>4

~** tf-~.. I I -~ ~ "'-~'\\:.. '~ f i IU -

  • ~~-~

F-J:. '1 *e *. 11 11: *:u 'U U!'S..--~ ro ~ r.J*'..!.::'.J ,., I I ~* ~! ~1... ~I ~* ~ k J, J. .. ~...... I

t,:":.

J:" t l ~-: ... ~1 ;:~i.;... ~~~-,.~Y--~7.... *t ~r..-!tf t~~ *:~.i'~~-~i~.. 0

i I

J. l;! ~*.....:..;*:..~,~~*~JL,.... ":,'-~~~

'liil.~-*:l>'."<oll~"Jlr.l

-~ ..... ii:: r~*..0.L~.,.., , -...... ~ :i!;,?~. J=,;,;~ ~~t

  • ti

.I ....,I

  • I..

.r: I j:' !'I ~ ' J ~) ~*.... J,. .. u } ) I I ,.,~ -~~ (J"... ~ -~~ ~- ~ "~y I.,!...-.!* I* . -~ r r*; ~ 's. *** l -;.=~-.. -= - I....,

  • '.u *:.',

~ - J u:...... "l.'.:"'.-;' ~~...., ~Ui "*;,.. .. _!_!I G 0 c

8 7 6 5 4 3 2 REV I ZONE 21 I 8-7 !REVISED TO INCORPORATE AN ADMINISTRATIVE REVISION. REF. AR 01345219 CHANGED A DUPLICATED TAG NO. MS-V12C TO MS-V120. HI I I IH !G F IE I jo I I I le I I I 18 IA 2" 2" CO-T-9 CONDENSATE SEAL WATER HEAD TANK ~2" y TO LOOP SEAL 302 141 (H 5) TO GS-V14 TO CONDENSER EXP JT 302 101 (H 3) TO MAIN VACUUM BREAKER SEAL 302-131 (F-3) TO VA-V16 TO AUX VAC BKR SEAL 302-131 (B-7) TO VA-V20A7B TO COSTE PUMP SEALS CO-V185 3/4" 3/4" 1/2" 1/2" 1" TO HYDRAZINE & AMMONIA TANKS 1" 302-171 (B-7) TO CO-V187 2" VALVE SEALS m MS-V12A HV-V3A MS-V128 HV-V3B HV-Y2A HV-V2B iJS-"ii1'2E HV-V1A MS-V12F HV-V1B FW-V11A HV-V10 FW-V118 EX-V15 FW-V8 EX-V158 CO-V106A CO-V112A CO-V1068 CO-V1128 DW-V1 CO-V112C CO-V109 HV-V8A CO-V107 HV-VSB CO-V34 HV-V7A HD-V27A HV-V78 HD-V278 SEALING WATER SYSTEM 8 CO-V183 I y 7 2" CO-V182B CO-V158 CO-V182A 1" 2" I 2" CO-V181 CO-V180 2 1/2" 3~ CO-V173 TO VACUUM PUMPS 302-131 (H-3) CO-V235 y DRAIN 2" ~*1~y DRAIN CO-V189 ~ 1/2" 7 CO-V159 y 2 1/2" 3/4" CO-V186 DRAIN 6 TO RC BLEED TANKS 302 690 (F 1) TO WDL-V253 k-CO-V177 'o/ FROM COND BOOSTER PUMP SUCTION 302-101 (A-5) SD-VSA 2" SD-V4A 2" SD-V58 SD-Y7A 2" 2" SD-V48 SD-V6A ffi-C-<< t "-C. INTERMEDIATE BUILDING SUMP PUMPS SD-V11A 8" I 2" SD-V3 \\. SO-V10A 8" 2" TO 11JRB RM Fl...OOR DRAINS SD-V78 2" SD-V6B TO CATCH BASIN SD-V11B SD-V108 SD-P-fA LS SD-P-88 48 ELEV 281' AIT FLOOR SUMP AIR TUNNEL SUMP PUMPS 2" TO CIRC WTR FLUME SO-V9A SO-V9B 2" 2" SD-V8A SD-V8B SD-P-6A SO-P-68 CIRC WATER HOUSE SUMP PUMPS 5 --r* 4 I *-* 3 SYMBOLS FLOW DIAGRAM TITLE REFERENCES 2 NOTES:

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. SEE DRAWING 302-165 FOR TURBINE ROOM SUMP PUMPS.

G F E D c w ~ Cad Fil" Nam" :302352 R21 I~ THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear z )> ,........,...,...., *,..,.* 1 CONDENSATE SEAL WATER FLOW DIAGRAM I A TMl-1 INTERMEDIATE BLDG.AIR TUNNEL, CIRC WATER HSE SUMP PUMPS 302-352 N/A NIA 121 I L ___________________________________________________________________________________________________________________________________ _J

H G E D c B A L 10 --1 EMERGENCY DIESEL GENERATOR 1A


____r-------- -E~-=-Y-1A -----

BLOWER LUBE OIL "~ 1: rTl u_~ --4 I u CRANKCASE PRESSURE ENGINE ROOM RADIATO_R_ ENCLOSURE 1 1/2u 1 1/2" JACKET COOLANT SEE DWG 302-354 1 1/2" 10 3/4" 1" z ~~*~ ~' ~~I ~~ g 2" ~ iil ~ 1 1/2H ~~*~ Q' ~~I 5~ ~n ~I a8 gn JACKET ~COOLANT ~SEEDWG 302-354 1" 3/8" 9 TO AIR START CHECK VALVES (ONE PER CYL) 3/4" 3/4" JACKET COOLANT SEE DWG 302-354 (B-6) EG-V29A 4" PILOT AIR VALVE (ONE PER CYL) AIR START CHECK VALVE JIB" (ONE PER CYL) 8 7 3/8" 1 1/2" 4" 7 TURBO CHARGER LUBE OIL EG~"3SA ENGINE L.O. SUMP DRAIN Sl " 6 5 -1 ,------__ ~E~~E~D~~EL GEN~R~~B- ___ _


__j EG-Y-18 BLOWER LUBE OIL

"~ 1: rTl ~~ I u CRANKCASE PRESSURE ENGINE ROOM RADIAfoR-ENCLOSURE I I --4 I 1

I

'---r; I 1 1/2" 6 1 1/2N I !h ~ z ~z ~ g ~g 0 w r ~ g EG-V19B 2" 1 1/2" EG-C-48 STANDBY HEAT EXCHANGER (LUBE OIL HEATER) JACKET I 2" r-. 1 1 /2" COOLANT ~SEEDWG 302-354 5 1 1/2" 3/8" 4 3 UPPER LUBE OIL HEADER 1" 3/4" 3/4" sJtEC~vg~~)02L~~J4~ EG-V29B 4" 4 3 3/8"

  • ~]

I 4" 4" 302-003 302-002 302-001 EG-V258 ENGINE L.O. SUMP DRAIN 2 ~~I COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTAT10N SYMBOLS FLOW DIAGRAM 2 1 13 I H-8,91 RE\\IlSED TO INCORPORATE ECR-12-00556 REV. 0 NOTES:

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOlED.

J. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.

4. NOTE REMOVED.
5. AIR START CONTROL VALVE, PILOT AIR VALVES, AND AIR START CHECK VALVES ARE NOT STANDARD DESIGN VALVES. THEY HAVE SPECIAL CONSTRUCTION AND ARE PART OF THE ENGINE MECHANISMS.
6. INSTRUMENTS NOT IDENTIFIED ON INSTRUMENT INDEX ARE FURNISHED BY DIESEL GENERATOR VENDOR, 3/M El-1.

H G II E D c ~ jcod Fll<> Name*.302353_R13 ~~ Exelon. ~; ~'-"""'""""-_..,_.-~DIESEL ~~~ERA TOR SERVICES ,1' FLOW DIAGRAM A.. LUBE OIL, FUEL OIL, AIR START 302-353 N/~IR1E3 1 -~--.J

I I H G F E D c B A 8 ENGINE ROOM -RADIATORE"°NCLOSURC - 3/8" 1 1/2" EG-V41A 3/4" 1 1/2 3/8" 1/4" 1 1/2" 3/4" 1/2" OD EG-V44A 2" I I 7 EMERGENCY DIESEL GENERATOR 1A EG-Y-1A 6 5 r-- 3" AIR COOLER AIR COOLER EG-V81A - J ::f. I 3.. ---.-- ~ f I TURBOCHARGER I I I 3" 3* I ,----_J I I ~DA EG-V80C I ~.I 11 F I 1H 1"


f L___

t----=.---:-:=------:i I 4a 4" 1" EG-V51A EG-V43A 1 1/2" LUBE OIL SEE DWG. 302-353 1 1/2" 1 1/2" 3/s" I I EG-V195 3/4" 1 1/4" 3/8" 4" 4" ~ 1 1/2" ~ 3" 4" ~ 8 15 15 ~,~ ~ T '< z c..I 0 3d lffi ~ ffi 8 0 ~ 0 " ~ 3" 4" 6 1/2" 00 5 1/2" 00 11/2" 11/2" ~i ~ 4" EG-V37A 1/4" 1 1/4" EG-V45A JACKET COOLANT PUMP (ENGINE DRIVEN) 5 1/2" OD _____QIGJ_N~ ROOM RADIATOR ENCLOSURE EG-V34A EG-V79A~ 3" 4" EG-V83A TEMPERATURE CONTROL VALVE EG-V.31A 5" 8 ~ ~~ ~,!z c,o w~ ~ 5" ~ ~ '< ~ 'i" g .,,~ '? " w~ § 5" 4" Is" EG-V59A

  • EG-V40A 3/4" EG-V56A EG-V70A 8

1/8" 1 1/2" EG-T-2A COOLANT DRAIN TANK FOOT VALVE EG-V62A 3/4" 3/4" EG-V60A EG-V61A 7 3/4" EG-V63A NOTES: LUBE OIL SEE DWG. 302-353

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POS!TlONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERW'ISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN TI-IE APPLICABLE ENGINEERING SET POINT DATABASE.
4. INSTRUMENTS NOT IDENTIFIED ON INSTRUMENT INDEX ARE FURNISHED BY DIESEL GENERATOR VENDOR, B/M El-1.
5. * ~g~~~~~o~~:g~EDH~NRDO c16~~E~~~~~L~GNK~i~A/B VALVES 6

5 4 3 EMERGENCY DIESEL GENERATOR 18 EG*Y-1B 2 REV I ZONE I DESCRIPTION C-2,6 I AD~INISlRATIVE REVISION TO CORRECT DUPLICATED COMPONENT TAG NUMBERS. EG-GB-tA/B REPLACED BY EG-E-2A/B. REF. AA 02425612. r-- 3" I ,. ~ ~';-1 :'1 AIR COOLER AIR COOLER H ENGINE ROOM -RADIATOR ENCLOSURE--, 3/8" 1 1/2" EG-V418 1/2" OD EG-V44B I I 4" 4" 3/4" 3/4" 1 1/2" 3/8" 1/4" 1 1/2" 3/4" 3/4" EG-V56B EG-V708 2" EG-V438 1 1/2" LUBE OIL SEE DWG. 302-353 1 1/2" EG-V39B 1 1/2" STANDBY COOLANT PUMP EG-V59B

  • EG-V40B 1/8" 1 1/2" 4

EG-T-28 COOLANT DRAIN TANK FOOT VALVE EG-V628 EG-V60B 3/8" I 3/4"

  • ~

3" e f : j j

TURBOCHARGER I

3" AIR RECEIVER l\\J5068) I ~---_J EG~-~ EGV-V196 3/8" 1 1/2" 4" ~ 4" "' 8 8 ~ ~ ~,~ "' T 3§ iii~ '? ~ uo I I f3 ffi "'0 w" 5 t;; 0 '5 I 3" 4" 3/8" 3/4" 3/4" EG-V61B 11------- V8DB EG-VBOO ~ c'~3~~~T 10 4" 1 PASSAGES .:'..!l~:~ ___ !"'l... -...:~.Lt I ____ _J 6 1/2" 00 4" 5 1/2" OD 1 1/2" EG-V37B EG-V79B 3" 11/2" 11/2" 3" 4" EG-V838 EG-V320 EG-V33D 3" 4" 4" 1/4" 1 1/4" JACKET COOLANT PUMP (ENGINE DRIVEN) 5 1/2" OD ___Q!G~~ ROOM RADIATOR ENCLOSURE EG-V34B TEMPERA lURE CONTROL VALVE EG-V318 EG-V45B 5" 4" I 5" felt;:: ~:'.S uo "'0 w '-' t;; ~ 5" "' 8 ~ ~,~ ~g Uu @~ § G F E D c ~I p ~ LUBE OIL SEE DWG. 302-353 Cad File Name : 302354 R20 I g EG-V63B 302-003 I COMPONENT & SYS ID INDEX 302-002 SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear DIESEL GENERATOR JACKET & AIR COOLER COOLANT SYSTEM, GEAR BOX LUBE OIL SYSTEM FLOW DIAGRAM TMl-1 I 302-354 20 SCALE: NONE !No.I oWG. No. "~.. ~ TITLE l1N11:.K~AL:1Nu L:uNL:uKK1:.Ni.;1:. IBA NO. 3 2 w I A

8 7 6 5 4 3 2 DESCRIPTION 'REVISED TO INCORPORATE £CO-C310004 H H VALVES INST NO A B C D E F G H I J K OPIS 1590 V48A V49A V1002A V1004A Vl003A Vl005A V1001A V1001D V1001C Vl0018 V1001E DPIS 1591 V48B Y49B Vl002B Vl0048 V1003B Vl005B V1006A V1006D V1006C V1006B V1006E DPI 1596 V55A Y56A Vl007A Vl009A V1008A Vl01DA V1011A V1011Q V1011C V1011B V1011E DPI 1597 v55B V56B V10078 V10098 V10088 Vl01D8 V1012A V1012D V1012C Vl012B V1012E F E G OF-F-3 DF-V73 DIESEL GENERA TOR EG-Y-4 DF-V75 DF-V43 1 FUEL LOW PRESSURE 7 ~b~R~U~~Lt6N~~gL DF-V76 DF-V77 I DIRTY FUEL DF-V74 DRAIN TANK IF-V69 L~~_~~_~~_~~_~~_~~_ LO -f VALVE MANIFOLD I I I I _--.J TYP INSTRUMENT DETAIL "A" HI E G F A c 7 / GAl 302-355 STATION BLACKOUT DIESEL FLOW DIAGRAM GENERATOR DIESEL FUEL SYSTEM FOR EG-Y-4

5. MAINTENANCE CONNECTION FOR STEAM AND/OR INERT GAS PURGING 4-NOTE DELETED 1

VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTI.JAL POSITIONS CONTROLLED BY PROCEDURES 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERiNlS£ NOTED 3 SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY ACTUAL DATA CONTROLLED BY GMS2 D NOTES: ""o N Iced FileName J02355 R7 I~ (J> COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM ~ 302-003 302-002 302-001 VENT TO AlMOS ZDF-V59 550 GAL DIESEL FUEL OA Y TANK OF - T-7 1" 1~ FILL I,* r--l I~I I~I ~I ~j I I I I I I I I I I I I


~

r------- SEE OETAIL "A" SEE DETAil "A" I I I I I I I I I 1" DF-V50B I I DF-V50A -l ---~-'----I DF-P-4A M Y ~1~NAl I I I I I I I I I I DIESEL FUEL TRANSFER PUMPS

OVERflOW, TO TRENCH I

I D~~V55B ~ ~ DF-V5,~8 JIlll/-.JJ I - - - T - _1_Df:"-~O~...J DF-V458 DF-S-28 DF-P-4B Y f.S. SIGNAL OF-V66 DF-V44 ~ DF-V46 DF-V1016 DF-V1015 OF-V57 PI .1599 ~ BLDG ~ WALL ~ JF-V51 DF-V64 DIESEL FUEL OIL FILL PUMP OF-P-5 ABANDONED IN PLACE OF-V63 1/2" DF-V68 DF-S-3 1/2~ BLDG WALL DF-V67 B D c I I A 8 7 6 5 4 3 2

1,-~ ' .. ~~;.1 *1....,*i.... -. ~:: *-* ~ ~;

r*.,.*

£.tie!: \\t*r ~'I f* l J ~ 1 I~: I! I i' 1'

~--------------------------------------------------------------------------------------------*--------------------------------------------~ H IG I I I I I I !F I IE I iD I I lc I I B lA I I I 8 I 7 I 6 I 5 4 I 3 I 2 I 1 8 STATION BLACKOUT DIESEL GENERATOR EG--Y-4 AL ~s--~ --- --T-- ----- --- -- - -- ----- ------ ---- --------_ ~.@:IY I I ~ EG-V138 EG-V978 SET @ 275 PSIG SEE NOTE 3 1 / 302 358 (E 3' I EG-V1009A I ~ - -*---- __j_ <<G-V184B B COMPRESSOR EG-P-IIB 1 1/4" 7 1/2" 00 1/2" 00 ,~js~ EG-V10108 EG-V96A VENT TO ATMOSPHERE 11/2" 00 A COMPRESSOR EG-P-IIA 6 1 1/2" 1/2" OD 1 1/4" 1 1/4" 1/2H 00 EG-V186 1/2" 10 TYGON TUBE y 5 1" 2" AIR RECEIVER EG-T-4C EG-V107 SET @ 90 PSIG SEE NOTE 3 1/2" 1/2" EG-V114 1" _1/4" 1" 2" OD EG-Y98C SET@ /2" 00 EG-V89D 275 PSIG SEE NOTE 3 EG-V187 2" EG-VSBD AIR RECEIVER EG-T-40 1 /2" 10 TYGON TUBE y 4 EG-V980 SET@ 1/2" EG-V115 EG-V108 y 275 PSIG SEE NOTE 3 ~~ G:~:ir 2--j FS-V646 FS-V647 SEE DWG 302-357 (C-3) EG-V161 EG-V112 11/2" 00 I EG-V99 3/4" LAIR DRYER PANEL I EG-Q-1 [SJ)(ill I i EG-V164 FROM PREFILTER EG-F-3 DETAIL "A" PURGE VALVE 2 1" REVISIO_"------ ZONE I DESCRIPTION E-3 REVISED TO INvORPORATE ECR-10-00560 REV. 0. 1" 1" 1/2" NOTES: EG-V102 1" NPS I DDT 3j 4<f,-V101 302-881 (E-7)

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2 All INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2.

H G F E D c ~I ~I 0 I Cod File Nom' ' 302356JU I~ THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear STATION BLACKOUT DIESEL FLOW DIAGRAM GENERATOR INSTRUMENT ANO STARTING AIR SYSTEM FOR EG-Y4 SHEETIREV. 302-356 NIA I 7 sCALE; NONE Q) A

1r---~8 --~---~---- 7 6 5 H G F E D c B A 8 PX ~ FS-V651 1/2" FS-V648 FS-V645 FS V656 10". 10" 1/1 (302 202(G 1) i FS V652 VENT ~----~I/*~I------------------ FS-V643 BACKWASH D.G. BLDG. WAll 7 FS-V655 FS-XJ-S4 3/4"1 16-. - -l i i 8" FROM DRAIN VALVES EG-V140, EG-V141 3/4" DRAIN PROVISION 3/4" 8" 1/1 1 BACKWASH FS-V642 6 8" I DIESEL GENERA:J0R EG-V"" FS-V644 SEE 1" NOTE 4 ~/~ 10" F5-V639 )o-.... --...:.::...-.....J FS-Vb41 8" 5 10" 6" 4 FS-V1S64 F5-V1557 1/2" 4 3 2 ~ 1 DESCRIPTION L~J REV TO INCORPORATE ECR-1O-00560 REV. 0 --I I H ' I I G I I I I F : I, I, 1------------- I I E I ~~ y ~ --------- r§{ -.J I ?


~

0.0. 1" FS-V649 FS-V1565 I I I I I I I I I I 3 I I I I I I I I I I I I I I~ 6' FROM YARD PIPING < 302 231 SH.l (0 2) 1 NOTES:

1. VALVE POSlllONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN mE APPUCABLE ENGINEERING SET POINT DATA BASE
4. SET POINT INFORMATION NOT AVAILABLE IN GMS2.

D c ~i ~ lead File Nom.. : 302357 R5 I~ ~----~-.-------------------;I~ z I~-*~-** *~--I~.. ""* -_.. I~ 0...... """IE I;::~ "TK~SKIE 12!14o(~O I STATION BLACKOUT DIESEL FLOW DIAGRAM I A GENERATOR COOLING WATER FOR EG-Y-4 ~~~-~~~'- ~~~~g~~NI~i'TR~~E~r~~~6~

tI/~o ~~o 302-357 302 001 SYMBOLS FLOW DIAGRAM

~ DWG. NO 2 I

8 7 6 5 4 3 2 3 I F-3 I REVISED TO INCORPORATE ECO-C310004 F G E ~ _. --.J TURBO CHARGER LUBE Oil FROM START AIR 302 356(0-7 1-------- (il\\ ~ l VERNOR PILOT AIR VALVE 3/8" 3/8" (ONE PER C'l'l) AIR START CHECK VALVE (ONE PER C~) .11~~HJ9~~ MAIN BEARING LUBE OIL BOOSTER HIGH CRANKCASE P PRESSURE SWiTCHES 1571 S _3) Tv?ON~6RORSHAuLtoR~WN 1 1/2~ @~ ~ ~ r--,---:--_J I I I 1/2~ (MANOMETER) ~ I + V 'I '-J TO AIR START AIR 1601 CHECK VALVES START II CONTROL VALVE L ~:':9 lE~-:=- l3~ j MAIN LUBE OIL PUMP I W/INTERNAL RELIEF I 500 GPM iC 900 RPM ~ EG-P-13 l:I~9 ~ I EG-V126ENGINE BEDPLATE __~U~P_______ y ~ SUMP DRAIN VALVE


~--------------------------l

(@\\/AIRSTARTI BLOWER STATION BLACKOUT DIESEL GENERATOR " ~ "" DISTRIBUTOR LU:~ 0.:i. EG-Y-4 TO AIR START -:. e'Y : ~ __ ~ CHECK VALVES / I \\ (ONE PER CYL) I IL I I I,, IH HI 1--t~A~--l ~"- t- - 1570 1570-1 I I I I ~ I -I-uPPER LUBE Oil HEADER PRESSURE SWITCHES ON~ ALARM; TWO FOR SHUTDOWN SIS 1 G E D EG-V127 EG-V133

D 302-358 1M1-1 1 VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHER'MSE NOTED

3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY ACTUAL DATA CONTROLLED BY GMS2 NOTES.

c "50"" 07 ':~9 STATION BLACKOUT DIESEL o~$,* FLOW DIAGRAM IA GENERATOR LUBE OIL SYSTEM FOR EG-Y-4 THIS IS A COMPUTER 1"'- GENERATED DRAWING 00 \\ I;PU NOT REVISE IT MANUALLY IIUCU'AII' / GAI '"atv ICod r~e Nome 30n5B R3 I~ CO COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 302-003 302-002 302-001 3/8" 00 EG-V122 VENT _~G-V116 13/4" 3/4" PRELUBE PUMP W/INTERNAL RELIEF 20 GPM EG-P-12 EG-VI20 3/4" I 3/4" I I EG-V121 3/4" ~ 4 VENT

G-V118

~G-V124 3/4>> LUBE ~,. OIL STRAINER EG-S~4 3/4>> I EG-V123 DRAIN .....l..l..a:- 1 1/2" EG-S-J f STANDBY La RECIRe PUMP W/INTERNAL RELIEF 10 GPM~ 3/4" EG-P-14 I C 1 1/2"9 EO-VI28 .EG-V119 1 1/2~ ~ BI I 1303 I" LUBE n all 1313 HEATER I* EG-H-1 [~ I I A 8 7 6 5 4 3 2

8 G L

  • o;'

.J ~ D I .,**~ Ll 1 ** *'\\* ~*' '**-~ r...: -~. __J i- ..... ~4 I l ..... !., -~-- ' L~ -~ ~ - ro


I F

I I D c

I 8 H IG I I I I F 'E I I i D (JACKET WTR. SUPPL Y~ TURBO-CHARGER '-D EO-V199 T L_ 7 TURBO-CHARGER '-DEO-V200 T 1/2" L _ ~IESEL _E~GINE __ J 6 IJACKET WTR. RETURN) ~ EG-Vl46 EG-P-15 ENGINE DRIVEN 1 1/4" EG-V148 5 DRAIN EG-V147 VENT TO ATMOS. 3/4" 4 DEMIN. WATER SUPPLY FROM OW V40 BR 2007 SH.2(e 2)1 fiAL\\ ~--~ I __ L __ ~ ~ OVERFLOW TO FLOOR DRAIN l.O. 1 1/2" EG-V143 ~~ yY L I ePlA PS H _,RESSuR~o~wrf~OLANT 1605 t 1 1(4" JACKET COOLANT COOLER EG-C-5 3 I I E I 3(4" 3/4" ~EO-V154 13/4" 13/4" 4" AIR COOLER EG-C-7 VENT EG-V152 I 2 ~ DESCRIPT10N 6 IE-6.7IREVISED TO INCORPORATE ECR-DS-OOB19 REV. a H G F E D EG-P-17 c !B I I I I I A I I I I I 8 7 1 1/4" EG-V150 1 1/4" EG-P-16 STAND-BY COOLANT PUMP 6 EG-H-2 STAND-BY HEATER L ______________________________________________________ _ ENGINE DRIVEN 5 I 4" -~ EG-V155 * ~ EO-V153 DRAIN DRAIN (lli\\ ~ I I _IJTAL\\ ~ 1 1/4" 3/4" 4 3 302-003 COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION 302-001 I SYMBOLS FLOW DIAGRAM DWG. NO. REFERENCES 2 NOTES:

1. VALVE POSITION SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS aTH[RWlSE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA SASE.

I Cad File Nome; 302359....R6 c ~I I ~ I~I I ~I : THIS IS A COMPUTER Z GENERATED DRAWING DO Arne Gen NOT REVISE iT MANUALLY r I~~ nOSK" 1O/0:;{~81 STATION BLACKOUT DIESEL FLOW DIAGRAM A 6


~

!----------------~---*-------------*----------~--------*~--*---~--------------* 8 7 6 5 4 3 I 3/4" 1 1/4" H G c TOTRNGCTR END USERS co-V387 11/4" 1 1/4" 1 1/4" I 1------- 1 1/4" I, I 1/4' NOM.CU T PVC +NOM.CU. +PVC r-- og-,~ OO-V420 (SEENOTE3) 1 1/4" 1 1/2" I DO-V432 DO-P-9 SUBMERSIBLE DEE:u~LL 0-PI 1722 1 1/2" 3/4" 1 1/4" 1 1/4" TRAINING CENTER & SIMULA TOR BLDG. 1 1/4" 1/4" 3/4" ~ L_.__-.l._L_ _ _J~~o'1scHARGE TO SINK VISITORS CENTER TO VISITORS CENTER ENO USERS 3/4" 3/4" 3/4" 3/4" 3/4" 1729 COl.tPONENT & SYS IO INDEX SYt.IE!OLSINSTRUl.tENTATION NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS DETERMINED BY PROCEDURES.

2.. ~'9-s+~~~~~l~~~lt~ ~~L~~~R~~~~;:F:fJ=i°r:o~y 3 SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN Tl-1E APPLICABLE ENGINEERING SET POINT DATA BASE G D c i:::::_:::;:::::..::...:::::=::+-Ex_e~!~~"~-'-------1~ DOMESTIC WATER FLOW DIAGRAM TRAINING&~~~~~~~~~~ ~~ULA TOR BLDG. Sl-!EET ~i:v 302-360 NIA 3 A

I NOTES:

1. VM.'IC. POSITIONS 5HOIW'I FOR REFERENCE ONLY ACl1JALP051110NSCCtnJla..LEOBYPROCEDURES.
2. All INS1R\\JMENT TAG NUMBERS ARE PREFIKED BY SYSTEMDESIGNAmRUNl.ESSOIBERil!SENOTED.

~. SETl'OINTVALUESF"OR RELIEF VAL\\'£SmBEf'OIJND IN IBE APl'LJCJ\\Bl.E ENlllNWllNG SETroMTCATABASE. 4.PIPINGO~STREAMOFVENT,OOAIN& ~rili~ l~""!;~ilr cr:... ~n 1~c~WW11~Eu~ir~THERWISE. ~. lHE?FllUO\\\\ING EOOIPt.IENT IS a..ASSIFIED Ml AUGll!ENTEO, ~C~cc-.?A~rcJ:.~A;.t~r-1:-~cT-~;e. SN-c-1. s"l°a= N

7. ~~:~~~~::S~EFL~n;: :~~~~~~T(~PMfu:~ ~

KEY'TYPICALALLR.C.PUMPS fl-UPF'EROOG.CILCOOL.ER i'J_-UPPER8RG.OILCOOLl':R !fl-MOmRAIRCOOLER Q4-LO\\\\EROOG.CILCOOLER 4.NS-1 *

H-H~~--;~--

9 7 6 5 &1/'l" FROMOECAYHT.aD5ED CYcu: COCl.JNG W"m 4 INSTRUMEMTATIONSTMBCl.S S'tM80LSFlOWDIAGRAM 2 I NUCLEAR SERVICES I

~
t:1z;z~ CLOSED CYCLE COOLING WATER A

82

I I H G F E D c B A FROM INDUSTRIAL COOLER AH-C-18 302-845(F-5) 8 IR~-y2A RB-V2 ~ 3/8" OD WATER c1ii PUMPS ES AH-P-2A & 28 IM 302-845(G-5 IR~-y7 ~ 8 8" S-1~11-7 RB-V3A 6" t" DRAIN RB-V8A 302-848 (F=2fl 6" 8" I 6" 1" VENT RB-V9 4" 6" I 1" .A. RB-V~~B DRAIN 6 REACTOR COMPARTMENT COOLING COILS L .A.RB-V11

  • 1" DR

---RB--- 7 6 5 1N VENT RR-V23A 1" VENT RR-V25A 1" VENT RR-V238 1" VENT RR-V25B t" VENT RR-V23C 1" VENT RR-V25C 5 l#jll 1#412 --RB 1D 1 ~ 2 4 ES 12" M ~L RR-V3A RR-V14A y ES 12" M ~L* RR-V38 RR-V14B y 12" ~L* RR-V3C RR-V14C y 'i' 4 3 12" 20" 12" VENT RR-V13 16" VENT RR-V16 RR-V4D 16" 3 2 REVISIONS OESCRIPTION 14 IVARIESIREVISED TO INCORPORATE ECR-14-00031 REV. 2 ~ 7 ~ 1 RR-1 V27A I 2" I I 12* RR-P-1A R.B. EMERGENCY COOLING PUMPS L SERVICE WAlER SCREEN AND PUMP HOUSE RR-P-18 __ _J NOTES: 5* EF-V5 EF-V4 TO EFP SUCTION 302-082 (D-8 TO EF-V3

1. VALVE POSITION SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE 14
4. SPECTACLE FLANGE IS NORMALLY IN THE OPEN POSITION.

H G F E D c I 0 I Cod File Nome ; 302611 R14 I~ 302-003 302-002 302-001 DWG. NO. COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM REFERENCES 2 CAUTION THIS DRAWING IS ALSO BEING REVISED BY ECR-13-00556 !!! THIS IS A COMPUTER GENERATED DRA'MNG DO NOT REVISE IT MANUALLY Exelon. Nuclear I"""""'""-'" ";!."I REACTOR BLDG NORMAL & ":l!r:£,;;;l hhr ~ EMERGENCY COOLING WATER SYS DESIGtl w DlllE FLOW DIAGRAM TMl-1 302-611 14 NONE w I A

c A I "*'-.:ir. .;- =..------- ~= -~

  • ~~

.....;-"'. I

~ I

....,.---~* G 0 .':..." '" ~'1* ~ -L;11NIC"'l.."""*~.... 'iL -R*- 1 __ '~ _J:__ t:..,;.;:.('* ~~* ~-~~i.:...: !.---ti ~..

I I BI I A 2,, IC-V77D ~ ~ 8 7 6 5 4 3 OUTSIDE SEE DWG 302-182 (B-6) 2 REV I ZONE DESCRIPTION 51 I F-6 I ADMINISTRAllVE REVlSION TO ADD VALVE LABEL IC-V99. SEE IR 01588123-02 FOR ADDITIONAL DETAILS. T -ISll PENET E.S )~ i

  1. 333 (SEE NOTE 7~

6,. 0 IC-V100 IC-V:4~1c~-~V:5:7+-r-------------------~~-o,-..i::..~,;. _______________________________ """' IC-V59 4" 2* 6" 1" I.* :*** I (1C-V86 IC-V87 1" ,,,:r ,-L_J IC-V7BD 1D COOLER I ~ ~1w I 1 1/2" ~ §5 ~I => z a,- I SECONDARY 1 I SECONDARY SHIELD WALL I I SHIELD WALL 3/4" 4" P T 3/4" VENT C-V56 E.S. 3/41" ISO. TEST DRAIN 3" 4" ~------------1 1g~~ )-------~ IC-V15 IC-V14 4" i 4" 4" 4" 4" 1" IC-V88 A_ 12" W-¥'1c-V73 FAI IPl-l"IC-V5 IC-V91 FROM DEMIN. WATER 302-163 (D.::j) IC-V94 IC-V93 I 1" RECIRC IC V89 [)(] r I 2* 8

e.

~ ~ 0 ~ 3 1/2" CONTROL ROD DRIVE COOLING COIL 1111111111111 I3~/2" 6" REMOVABLE I : SPOOL 1.. VENT ~ t:j VENT IC-V70 IC-V69 3/4" R.B. S-1 S-11 u ~ IC-V74 1/2" IC-V95 INTERLOCK OPENS Er - - -? OR ~=-NvJ~1~3vJCc~5SEs F.O. PEN ET E.S~~ I 6" I I ,l_\\!J~-A-1. _i_t;3D2 (SEE NOTE.71'~ I 0 0 I ~~~, ......... ~ ~..........,........ -."""~'-l"Qii~... "'!1!... ""'!I'~..... (><)-""!""!"!~~ 3/4" IC-V3 ~ R.8. DRAIN I ISO. TEST IC-V61 DRAIN TO IC-P-1A & IC-P-18 AUTO START INTERLOCK.f- - _..l < 550 GPM CORROSION MONITORS IC-V21B IC-V728 'Y IC-Y63A

  • 3/4" 2"

OVERFLOW IC-V7A .:;::.,. 1" (SEE NOTE 3) ' 3/4", y 8.. IC-:V2~A B" VENT 2" SURGE TANK IC-T-1 1C-Y46 IC6 TE 2" 1/2" IC-Y11A Ll-1130 IC-V66 IC-C-1A IC-V62A 'Y IC-V78 INTERMEDIATE COOLERS (SEE NOTE 3) 1" 3/4" y 8" IC-V22B IC-Y528 'Y 8" 'Y 8" 1" IC-V48 2" CHEM FILL IC-V104 IC-V67 INTERMEDIATE COOLING CLOSED COOLING CHEMICAL MIX TANK IC-T-2 IC-V49 INTERMEDIATE COOLING PUMPS 1" IC-V47 ~ I \\1 8" H G F E D c §j z 9 NOTES 11~ I Y 1" DRAIN 1~ ~I c~,,=,11-, -,~-* -, :io=20~20=.,-, ---~1~ Cl 8 R.C. DRAIN TANK HEAT EXCH. IC-V38 y IC-V39 IC-\\110 (SEE NOTE 3) 1/2" 7 1" Ml F.A.I. IC-Y20 6 5

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

.3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.

4. FOR INSTRUMENT AIR SUPPLY TO VALVE IC-V.3 SEE DWG.

302-279 SHT.9.

5. FOR INSTRUMENT AIR SUPPLY TO VALVES IC-V4,IC-V6 AND IC-V74 SEE DWG..302-279 SHT. 8.
6. FOR INSTRUMENT AIR SUPPLY TO VALVE IC-VS SEE DWG.

302-279 SHT.10.

7. VALVE FAILS IN AN INDETERMINATE POSITION.

4 302-003 COMPONENT & SYS ID INDEX 302-002 SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM r--~~~.--~~~~~~~,~ AITierGen INTERMEDIATE COOLING FLOW DIAGRAM TMl-1 302-620 SCA!..£: NONE A 51 NO. OWG. NO. TITLE INTERFACING CONCURR N E BA NO. REFERENCES 3 2

H IG I I !F I I I 'E I I I I iD I I c I I I I I I I le I I I I I I I IA 8 I 7 I 6 I 5 4 I 3 I 2 I 1 I iPJ SUPPLY PRESS SOLENOID HOOK-UP FOR VALVES MARKED 8, ( 12 PLACES ) TAGGED VALVE I I I SF-V84A R-r

  • 3/8" f.~N~~G IT HI

~°cs HI 198 aiil'4!, ~} TUBING TEST ~ \\ ~ CONNECTIONS SF-V848 l 0 LO FUEL TRANSFER R.

  • TUBES I

FUEL TRANSFER CANA 6" 4" SF-V31 REACTOR 3/8~ CAVITY RB SUMP FLOODING ISO (o~~1~J tJ---------11 ~

  • I y

4"


R.B.

3/B~ ED ED ISO SF-V59 T (Jf~f)tJ---------1~4 +--s1 { {1 QUICK DISCONNECT ~ SF-V1B SF-Vl9 B" 14" 302-640 (F-2 8" 4" THIS PIPE SLOPES TO PUMP (MAX ELEV 343'-0" 4" 8" ~ PNL 1A (Lr'\\ (LI\\


~----~

8 EL 344' 1 TYP BOTH POOLS 2" ei 4" 4" 4" 4" 4" 2" ei 2" ~ 2" ~ WEST SIDE (OUTLETS) SIPHON BREAK 1 /2" DIA HOLE 4" 4" '1 ELEV !_4-0'.=_G~ ~BOTHPOQS SPENT FUEL POOL "A" 435,000 GAL 8" 4" 4" 4" 4" \\.') \\.') \\.') \\.') EAST SIDE (INLETS) ~ I A 9 4" c----@ SF-V27 ELEV 305'-Q" II


1-C

/::,. ----------_ -----.--- --~.;:----_--_-_-_-_-_-_ --~ 1' i I rs;:0 tJ '~1 c ~-*-" '"'I ' O, ~

  • C-W

~= ~ co~~~~INUATIDN I ~ I FOR DWG 302-610 I ~ I EL 30 B" SEE t T 0i'\\ 304L /::,. SF-V3 I I I I I I I I I I 1" L __ _ 1/2" H~ VENT 171 3/4.:l I B" sF-vs2I 8" 8" B" I SF-C-1A SPENT FUEL I 3/4" COOLER I - -*- - J t 304L SF-V12 /::,. SF-V13 <@) - 4" BLIND FLANGE FOR TE1'tl.E_ DRAIN SF-V50 SF-V34 SF-V28 2" 3/4",1 SF-V72A B" B" 4" FROM BORIC AaD PUMP 302-670 (0-3) 8" 4" 14" ~ k~ 4" WEST SIDE (OUTLETS) B" REV I ZONE 34 IC,D-2 I REVISED TO INCORPORATE ECR-14-00032 REV. 2 (U\\_ _(Lr'\\ PNL 18~ ~----~---- 12198 8" SF-V51 H "I 60 LO 199 LO SF-11 14" 14" Ir 4 4" \\.') \\.') lj' IT~- '" '" I ~F"l"ff, I A 1-U EL 323'-6" G SPENT FUEL POOL "B" 215,000 GAL ELEV 305'-o" 0s\\ c~ SPENT FUEL CASK LOADING PIT A0,__ £ ~---~ 4" B" F ~ I SF-V72B E SF4 P12 ~ ----1 - "1P_ - - +- I y I 1 I ~.... 3/4" 3/8" f-0 ~ HOSE Ecr:it~~ ]~ S-lll I S-1 SAMPL SF-V77 ~~ 4" 8,. SF-V8 SF-V10 EL 305' SF-V6 COOLING WATER FOR CONTINUATION SEE DWG 302-610 VENT 171 3/4".118" B" in ((SF-V54}_ 8" SF-C-18 B" I I /::,. ~ B" SF-~ I B" ~l sF-v1sl_J -.ob. B" SPENT FUEL i/4" s1 COOLER - _________________ !TYP - __ ~~5~ - _ js_::-~16: - - - - - - - - - - - - - - -B~ - - - - - - - - - - - - - - - - _y _ - - - - - - - L_C TO OR FROM BORATED WATER STORAGE TANK VIA DECAY HEAT SYSTEM RECIRCULATION AND TEST LINE 4" NOTES

1. VALVE POSITictJS SHOWN FOR REFERENCE ONLY.

ACTIJAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRU~ENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

J. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SETPOINT DATABASE.

4. VALVES ARE SHOWN IN NORMAL OPERATING POSITIONS OF COOLING AND FILTERING WATER IN SPENT FUEL POOL B.

USING SF-P1A AND SF-C1A FOR COOLING.

5. ALL PIPING IS PIPE SPEC [9-,SEISMIC CLASS AS NOTED,&

NUCLEAR CLASS N-3 {EXCEPT AS NOTED) ~ 4*

6. 8 & W SUPPLIED INSTRUMENTlON IS DENOTED WITH AN ASTERISK.
7. FOR DESIGN CONDITIONS SEE B&W DWG 27553f.

NO. 302-003 302-002 302-001 DWG. NO.

q ~~

34 ~ COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM TillE REFERENCES D c ~-*34' 01 ~ 9 ~ I L;aa ~lie Name : JUl!bJUJ<J4 I~ = r--~~~~~~~~~~~--1~ THIS IS A COMPUTER GENERATED DRAWING DO NOT REVlSE IT MANUALLY ExeJ,g,i:!*

  • .. ;,,.;: 1 SPENT FUEL COOLING SYSTEM FLOW DIAGRAM TMl-1 302*630 34 IBA NO.

A 1 8 I 7 I 6 I 5 4 3 2 I L-------------------------------------------------------------------- ___________________________________________________________ _J

I ' H I I G 0 c B IA I ~ ~~~(t).Q. 1AOQ:D ~*M.'of v..... 8 v ¥'11._CD { {_ tr-V'lt I I I ~ ...... fii\\_ /U\\ I?----~----~ I I I I c~ ~-~! t!Qfil I 't'At'<f 'OlflOJrilt W1!N rQlll: llOU!tNC( CINI. 1" ACY\\IA&. toOSI~\\ ~l'llOW:O t'I' "oct~ 2: ""- "'lt-....rJir1 TAC M.tloll(Jt$ It/ff H(f l((O 11 j'($t(W, 0Ulc.NA10llt ui...&.n OfMCit.IX,tf()rCJ) l ~*~~,~~~~T,.;= 4 ~~1'J~,\\~~=-~ ~ ~"'::"et~~-nfllt*1l"°..:~ AS tolOl'CM

  • I* W ~

.... $,.,,..._lilnorot.. Clfl!QytD *?M AA~ 'rot~(OfrrOfOi!SKl..

  • t.,..mu I

4 I V-~t>>i.".ccnOH to n.rx ltCS ~ NtOSIP sr-.w1 ~~~ 2- '1-:.,~.:J'e-1 n;... '1111, I 3 I I I 0 c p:iiliiJ!iii:Jiiilii:ili:=====i..--------~i 1--~~~~~~~~~--Jl ~~=-::oo Ex.Lv.. ... 1t lilt~ IT M4"UAU.1' __, -""~ I h~ ,..-'"----'-~~.;;...!~--===---------l

  • - -~- " -_... SPENT FUEL COOLING SYSTEM -

~~,,,,, A **,.-r: fl.OW DIAGRAM A .,,,~ I~ I

r------------------------------------------------------------------------------------------------~ I a 1 6 s 4 3 2 1 I I ~~ 1' REV ZONE DESCRIPTION ~ 85 H-6 REV. TO INCORPOI I MTE ECR-14-00032 REV. 2 3* H H G F E D c B I IA I 3" R.B. OH-V21 H bt~~gHPli~ DH-V208 § 1/2" OD TO RC-T-1 DH-V228 10 ~ j 310 TO EL. 281'-0" lo" ~ 302-711 8-4 z DH-V185 3/4" TO RC-T-1 302-711 (B-6 DH-V48B 150. ITST &:DRAIN I !303 N-3 N-2 14" SCH 10 GUARD PIPE TO EL 281'-o* 3" DH-V20A 10" 4" 4" 6" DH-V48A I.... *' TO AUX.BLDG. SUMP 302-690 (H-5) TO PRESSURIZER SPRAY LINE & RC-V4 302-650 (G-6 302-690 (H-5 CLASS "E" INSULATION FOR CONT. SEE DWG. 302-713 1" R.B. I dz. ISO. L & ~~!IN I I i R.B. ! EO TO DH CLOSED CYCLE -;I;' C.W. SEE DWG. 302-645 J1" DECAY HEAT REMOVAL COOLER 10" 1 1/4" =- (oH1\\ ~ TERMINATION I,__, ' " I ) ~ I,__, I I '""* T OH-V168 FROIM 3~2':'.'6~~.. (~~:) LE> ~' OH-V170' ~

  • r-v2.

I di'06 1/2" 1 1/4" '-auJCK DISCONNECT PX 59.3A OH7 PT1 PX 593B 302-651 (0-3) TO nB" CHANNEL INSTRUMENTS RC-LT-1034 & LT-1036 302-651 (D-7) TO "A" CHANNEL INSTRUMENTS ECCS SUMP DH-V178 R. DH-S-2 RC-LT-1033 & LT-1035 ~STRAINER [ ID ~r" __________________ J ro:"iiv** 11 llH~~~I~ 1111,r ~:'.'":~ er* ~~~:""" (~~~ NAJ-fEE~~LIES \\'>... 14N P-352 !~H-V6A 13/4" SS LINER CONTAINMENT VESSEL LINER 24" SCH 10'S VALVE GUARD 14" P-354 d, <( <>-z ~o ciF ~~ ~~ ii! N I <( 1/2" 00 l (FE'\\ T\\e'Y(NOTE 10) DH-V188A SEE NOTE 7 _____(FE'\\ -~ {NOTE 10) 'PX' 5948 1 1/4" ~~~ 1/2" 00 DH-V189A TO BED PLATE 1.. FLR. DR. @ WDL-V720A SEE 302641 {A-10) 14" DH-V24A IDH-V12A I LauicK DISCONNECT 14" ~ 3/4"' llT ...'.....JeHJ-1 ~/4" DH-V1B4 OD 12" DH-V12B -;:r;- 11""- OUICK OISCONNECT REFUELING WATER CLEAN-UP 302-630 (D-1 FROM SF-V44 FROM SODIUM HYDROXIDE TANK 302-712 (F-4 DH-P-1A DECAY HEAT REMOVAL PUMP DH-V192B .~ ~ 11 INSIDE I OUTSIDE CUBICLE CUBICLE DH-V60A (SEE NOTE 3) TO FLOOR DRAIN LEAK DETECTOR DH-V59A N2,S-I ' S-1 NOTES FC DH-V61A {NOTE 11)

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERVVISE NOTED.

3/4"

3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE
4. SYSTEM DESIGN BASIS -

SEISMIC CLASS I

5. NO INSULATION REQUIRED WITHIN THE AUXILIARY BUILDING EXCEPT FOR PERSONNEL PROTECTION.
6. FOR DESIGN CONDITIONS AND 8.& W. INSTRUMENTATION SEE B.& W. DWG. 27554F & DWG. 135756E.
7. SEE DRAWING 302-641 FOR PUMP CONNECTIONS AND AND AUX. EQUIPMENT B. DH-S-1A/B INTERNALS REMOVED.
9. TEST PLUGS ARE NOT INSTALLED DURING PLANT OPERATION.
10. DH-FE-231A/B ORIFICE IS NOT INSTALLED.
11. SEE DWG. 302279 SH.1 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR.
12. DH-V27 IS BYPASSED BY AN OPEN 14" MANWAY VENT 12" 4"

3/4" 1/2" OD DH-V1aas SEE NOTE 7 DH-P-18 DECAY HEAT REMOVAL PUMP DH-V16B VENT SEE DWG. 302-671 (F-6) ~~~ o->- 8: g ~ ~~~ ~gg DH-V49 8" m 6 6" 2" DH-V153 3/4" 00 1" (SEE NOTE 3) =1 DH-V57A DH-V1S1A DH-V14A

  • L,,... r--@

[~- 1298 DH-V167A T 3/4" DH-V5A ~~~ 11~IE I ~~~~~,-,,, FC 1/2" Ii DH-V148 FROM SODIUM HYDROXIDE TK. 302-712 iE-4 DH-V618 {NOTE 11) 1" 302-00.3 .302-002 302-001 DWG. NO. FROM CA-V256 302-670 (E-9 MIES DH-V5B 14" COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM TI1lE REFERENCES ~I~ .. N > IQ,, J_e5 ~ o'" ~g~ °'I°' Li. g~ OH-V27 I {SEE NOTE 12) VACUUM BREAKER ATM SET@ SET@ 2 IN HG 3 PSIG a" I ~L tw VEN;r-1~ -11 98 ~N m;::: ~~ g TO MU-V14A 6" --1 302-661 (A-4) .. 1 TO MU-V14B 302-661 (A-2) DH-V44 3/4" DRAIN ~ ~ TUNNEL SUMP G F E D I IC cl ; ~File Name : 302640 R85 I I~ THIS IS A COMPUTER GENERATED DRAWING DP NOT REVISE IT MANUALLY Exelon. Nuclear DECAY HEAT REMOVAL FLOW DIAGRAM TMl-1 302-640 NONE IBA NO. ~ ~ A 85 L 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 _J

i I j H i.

G I

l i F l l jo l JC I B [ I A !n ttf-f£-:!.1!1./fiCJU:t"f.l!i~l.. Mk.l:J"n.

~ ~

O'Jr.O..~1:n ~*

  • r~ sso:rnio... ~w1t -'i!!

N.'!~S !1;)....._~ "-"'l.lt~<~Jt. !.:: GO-;/;?l ~ lllr.'A.'\\~ 1IY VI Qo>!f.I "" YIJOU.l m*l 4 3 G 0 c >-~~~~~~~~~~~~~~~~_. !1 DECAY HEAT REMOVAL fLJW Ql.;CW-AM ...J A

~!~ REVISlONS ZONE I DESCRIPTION 1 6 I ALL I REDRAWN PER ENGINEERING REOUEST AND £CO-014341 G 2 ~I~ 3/4" 00 ~ I C;; ';1 2" 00 3 1/4" U 1077 1/4" U 1078 EXTERNAL DIVIDED RESERVOIR DH*T-3B (OJ ~ 1/2" ~:c 3/4" 00 -';= ~~ 3/4" 00 (OJ ~ 5 I 4 REMOTE FiLL REMOTE FILL ~ n n 1080 I," 00 I," 00 1/4" EXTERNAL RESERVOIR DH-T*2B M~ OIL OIPSTICK~ A 6 3/4" 00 ~I~ I ~ ';1 2" 00 DH_T-5A OPEN OVERFLOW TANK REMOTE FILL 7 1/4" I-- I-- LI 1073 1/4" LI 1074 w w 8 ~ ~ 3/4" 00 ~:u 1/2" ';1 2" 00 3/4" 00 DH-T~ OPEN OVERFLOW TANK ):1/2" DH-V161A,., EXTERNAL RESERVOIR LJ DH.T-2A 10 I 9 LI n 1076 I," 00 1/4" H G EXTERNAL DIVIDED RESERVOIR DH*T-3A 1/2" 00 1/2" 00 ~H DECAY Hl. elSD CL::;. WTR ..--L--cJ 1 2" 1 ~~~~)N-SEE OWG 302645 E 1/2" 1/2" 1/2' OD ~ OH-V155A 1/2" 00 1/2" co ~ DH-V157A 1/2" 1/2" 00 1/2" 00 1/2" 00 OH-V155B .-c-o 2" 1 1 2' ( ~~~~;N~~E~L6~G.C~~2~T~ 1 (E-6) 1/2" 00 1/2" 00 DH-V1578 c o 1, VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED By SYSTEM OESIGN,6,TOR UNLESS OTHERWISE NOTED 3 SET POINT VALUES FOR R£LIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE 4. SYSTEM DESIGN BASIS - SEISMIC CLASS I NOTES THIS IS A COMPUTER ~~~E::~~ ~:~~~~~~~yIAmerGen ~ J 01 I"'""' """ " I~I 1/2"' 00 -0 m DC-V37B OC-V383 OC-V398 1" 11" DECAY HT, CLSO ,,...~----~-'------~~-<,' ~~g'M WOA~~~3~~P~L~EE Dwe. 302645 (0-6) oc-v40B 1/2" 00 FR)M OH-V18B SEE DWG. 302640 (F-4) DH-Vl007 DECAY HT. PUMP DISCH. SEE owe 302640 (0-3) 1/2" 00 DH"T~B OH-V151 I 1/2" 1/2" 00 "2" OD 1/2" OH-Vl015 ~ -~ 1/2" 00 1/2" OD DECAY HT. ClSO CLG WATER SUPPLY FROM OC-V36A - SEE DWG, 302645 (0-5) 1" 1" 11",L

7 DC-V37A 1"

11" 7997 7997 JlJwlJ c"o~~fe lJWJ Ii oc- ~ OC-V39A V40A "*'1" 11" FROM DH-V188 SEE OWG 30264G (f--4) 1/2" CO OH-Vl:J06 DECAY HT, PUMP DISCH. SEE OWG 302640 (0-5) CV 1/2" 00 L~III-~ -- qJ~) J ~~~MO~~ I 'Ie..,) 1 1/2 ('H-V77A DH-V78A CH-Vl014 3/4" ~ ~ H-V75' 'T C<SJ DII-V76A Fe B o c LI I I I o U "'~ """'" "" 00 DECAY HEAT REMOVAL A 6 "212-29-001 O£C"1' Hl RI.IV PUI.IP BRG OIL TANK ""'V~~fi ";?-/.. 'a:'~ DECAY HT. PUMPS lA/8 AUX. SYSTEMS A DRAIN 0 VOL vnOA SEE DRAIN @ WDL V720B ~ SEE ~ "'-212-29-003 OCCAl' NT RlolV PLlI.IP I.IOT BtlC Oil T.\\NI< 0A1t FLOW DIAGRAM QWG. 3027-9 (A 3) DWG 302719 (A 3) [-212 n 001 DHR PUI.IPS RDolOTE OILING - PIPING

    • 1\\

owe NO. 5H REV.

~_:~

~:::~~S~~~NI~A;:X .~ TMI.1 I 302-641 I' 1 1 6

102-001

$YIolBOLS FLOW DIAGRAM SCALE: NONE 140. DWG. NO nnE INTEHACING CONCIJRRENCE A NO REFERENCES 10 9 8 7 6 5 4 3 2 1

c G A L I-I- t H DC-V278 I~ ~ lO"DlO"

  • . "",,,.w Ii NOTES
1. IIAlVE POSlT1QNS SHOWN FQR REFERENCE ONLY ACTUALPOSIT1ONSOETERMINE08YPROCEDURES 2,ALLINSTRUMENTTAGNUMBERSAR£PREfIXEOBY SYSTEM DESIGNATOR UNLESS OT11ERI'i1SE NOTtO 3, SET POINT IIALUES fOR RELIEF IIALIlES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATABASE

"[ 1219B OC-V248 ~ CHEM n Fill OC-V568 w* ~ DJ~IN 3/B" 1/2" DC-II27A I~ ~ DECAY HEAT CLOSED COOLING WATER PUMPS BEARING COOLING ~ cb ep _'I-illg "l ,. I ~ 1"4\\1228 DECAY HEAT SURGE TANK OC-T-1B (ii\\ "'N~ FROM DEMIN WATER MAKE-UP 302-16J(C-I)~ OC-V200 ~ VENT DC~V~9B n }- OC-V628 I"RECIRe 2" -{:B:)-_:":::=---j"

J SPRAY PUMPS (REACTOR BUILDING) MOTOR & BEARING COOLING DC-V32B(;60C-V338'" DC-1I348

,~'u, fi~,',.t (:-N';;~B,) DECAY HEAT SURGE TANK DC-T-IA aD lS 96 AN DL DC-V22A Ic'\\. "'N~ FROM tEMI~O;~~~ (c~~j~ OC-V20A ~ linn ,0 }- OC~\\l19A ~ OC-V62'" -:.>01 2 l"RECIRC 2" ~ ~-- ~!rr\\ ~~ 10" FROM ~~~A;o~~~ro REMOVAL PRIMARY COOLANT DECAY HEAT REMOVAL SYSTEM ~ ~ ~@- 10 w* DC-'J51A 116" tll\\ I" ~ m OC-V54A r" SE~~CtEY CHJ~TER ~/y 16"~ DC-V5A ~~T~C~[H~:II'o1R~~~o~~~o~ ~~~T~~C~[Hg:II'o1R~~~o~:~~ E oo_:~:t "_:;:j+ 2" 2" S Y r TO NUCLEAR SERVICES CLOSED t~="==============t========::;::==:;::':*~~--O....i* t-1 -+ CYCLE COOLING (NS-V83)3" (30261O(B4)~ P """t DC-V4S8 1 3/ 4 1 3 / 4 "3" 1 3 DC-\\i59A 1 DC~~~ ~ Y I 01 W "COEAA ""~"" ""CO 1=== I CYCLE COOLING (NS-V81>>)" 3" 302610(8-4)1-- G c I I - I I I-I 10",ROM I ~_I DECAY HEAT R(MOVAL-- SEE.302-640 L--4~_===---tt-MAKE-UP & PURIFICATION PUMP MOTOR & BEARING COOLING DC-V42A AIR rlI----"1l1l(f'+ S~~b~Y s EPOSlT1ONER AIR~ 3" VENT SUPPLY NT"....:J1: .. ----t*J---- [""fM_fh..", OPERATOR V£NT T¢;L~D VALVE SOLENOID HOOK-UP DC-V61A SOLENOID HOOK-UP FOR VALVES MARKED * ~ DC-V41A 3" FOR VALVES MARKED.. (TYPICAL 2 PLACES) t~:"'Qo_:J._';";;:Jl..i:;"__~_..J._l.:;:/'.*~~~."t-;;"1 (TYPICAL 4 VALVES) G~~'iR~;O ~~:~,~~too l~~::~::::~::~:::~:::::::::=====~:::3:~~~'~ I::"::;'~"~~::"~"~"~'"~"~"rl'f-=:':::::":::~:;;-;~~;::;:- 00-"" ".

. ""=" ",,',,

OC-V15.o, ,"I","" I I. '~-"'!"""...&..;;"""';'---rI I,' I '/d 11 co",,,,,,,, & m " '" 'M'.' A ,rl y ~~~,:'-,,~;

~; ~'~~"O~
;'::~ON" ""~,,~~;;~,;

'---==---.::...-----.-,:z," m' ~"",",,,"" 00""" 3 2 1 5 4 7 6 9 8

I I H G F E D c I B A TO RC DRAIN TANK 302-690 (H-6) J; 8 6 10" N I g (TYP 3) ~ J;i~ (TYP 3) 5 4 NOTE 15 2500-4 2500-4 NOTE 15 N-2 S-1 I N-2 S-1 N-2 S-1 I N-2 S-1 TO CONDENSATE POT 1 2.. TO CONDENSATE POT ~ ~ T.- "'I I ZN \\ 'T 1/2" 1:5 N T-3 3/4"* ~ D ~V58 RC-V57 T"' RC- ~ ~ 1/4" 1/2"

  • . SEE NOTE 13 lo zz I

-~. -~

  • (£ llf----.VENT TO R.B. ATMOS, 1"

l" tr R~-Y18 1* 3/4or FROM Nl-V3' T 1" 302-no *.cc N-3s-111 'l'Rc-vso -8) ) 1" -~ I SEE TO RC-V1204 302-651 (E-6) RC-V46A SEE NOTE 1" I 13 1" 1/2" RC-V40A RC-V41A s~~Tu l1 --WALL-RC-V16A ~ 00~ ~ ~4 (/) ~:::!!: N"-0 z I"' gu_ 3/4' 00 CLEAR TUBING USED AS LE\\H INDICATOR RC-V14A 8~ ~ e->--" ~~ .. :s ~~ PT-5 302-690 (G-5 6E\\_ ~~ J; I ~z li-1 >---I zS "'m 0"' ~~ 2" ~ RC.,.-V19 N?JE FIO~o;~6L6~NJ(g~~) ) 11/2" 11 r--u TO & FROM INTER COOLING ~ SEE DWG 302-620 ~ TO COMPUTER !POINT 404 I r I 111,.*/ =~l'.;J/"'DF v I __,_:_:;__. lwtsnNGHOUSE I 1 _ r Rr.PIJUP 31" ID RC-P-18 2 1/2 8 7 6 ~--------~,;_ J;l~ NI'! 10 zz J;I! NO I'° zN RC-V6~ 13/4" RC-V61 I

1J; N

N 1/2" .'d. :4: SEE NOTE 16 I ~~21* 1

:ii ~R~261 2112*~

~ FROM MU-V95 62\\ Fl~~2~~~~ %J~7)0)1 1/2 I TO & FROM INTER COOLING ~ SEE OWG 302-620 ~ 1 1/2" ~~~~~i.:; (~~~s )21/2" i~~~~-' FROM MU-V86A 28" ID FROM MAKE-UP PUMPS 302-661 (G-1 & MU-V94 5 28" ID FROMI ;~~~~~~E~;~) ) 1 1/2" J TO & FROM INTER COOLING ~ SEE OWG 302-620 ~ FROM MAKE-UP PUMPS 302-661 (C-1 & MU-V868 2 1/2" 4 TO LETDOWN CLR'S. 302-660 (G 2) 3 36" JD 3 2 REVISIONS REV I ZONE DESCRIPTION 62 IVAR~SI REVISED TO INCORPORATE ECR-1.3-00099 REV. 2 I --- t~1s~~f:cu1Ts I ,,.,, -w I R:C2 LI RC2 <lf2; Tl DETAIL 1 ,.-JI----~ , 7![!; 777 ~ DETAIL 2 ~' /RC4AL ,T~;


TOICS L -

.....,. -.*TO COMP PT 405 DETAIL 3 SEE NOTE 13 RC-V52B 3/4" RC-V518 ( ~ 4 o1 ~~ 6 ITT "l' ON H G F RC-V15B 1M ~ ~., "'I-"' .1- ~ NOTES STEAM GENERATOR RC-H-18 ~~' 1/2" 0"' ~ N-I I ~ z RC-V40B FC RC-V418 FC 1~ 1" RC-V468

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2, ALL INSlRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OlliERWISE NOTED.

3. SET POINT VAWES FOR RELIEF VALVES 'rO BE FOUND IN THE APPLICABLE ENGINEERING SETPOINT DATABASE.
4. B & W FURNISHED INSTRUMENTATION MARKED WITH AN ASTRISK (*}.
5. SEE B & W DWG 135756[ FOR PROCESS AND INSTRUMENTATION SYMBOLS AND IDENTIFICATION.
6. FOR DESIGN CONDITIONS AND B & W INST SEE 8 & W DWG 26553F.
7. FOR 8 & W FURNISHED PIPING SEE B & W DWGS 131942E, 13194JE, 135841E & 135842E.
8. ALL PIPING ~

IS SEISMIC CLASS I & NUCLEAR CL':(ss I EXCEPT AS NOTED.

9. ~irrcr~~GcJ?ss1111~EISMIC CLASS II &

E lO.ANL~crr~~GcLlfss 1 11 ~~~~~ ~~A~~-&t 11.ALL PIPING 'fr> IS SEISMIC CLASS I & I D NUCLEAR CLL-Ass I EXCEPT 1" ~~1 ~s g~ ~~ 3/4" RC-V53~ 3/4'.' 1/2" !"~ z~ ~ffi ()~ <<o 2"' J; ~-~ g~ -~ ~; ~ >~ ffi '<lo I NO~ Z<< '° RC-V16B AND SMALLER LINES WHICH ARE SEISMIC CLASS I & NUCLEAR CLASS II EXCEPT WHERE NOTE 16 APPLIES. 12.HIGH POINT Cf' LOOP SEAL TO BE 12' ABOVE HIGH PaNT OF PIPE RUN TO R.C. DRAIN TANK. 13.TEST CONN'S. ARE PROVIDED FOR HYDRO TESTING AND/OR FLOW PATH INTEGRITY TEST OF VENT PIPING. 14.A~~cL~~GcL!fss1s3.SEISMJC CLASS Ill & 15.INSTRUMENT IMPULSE LINE WBING IS PER GPUN SPEC. SP-900044-001 STNLS. STL. UNLESS /(\\ OTHERWlSE NOTED. RC-V148 --w 16.BOTH LINES (RC-V25 & 26) OF lliE RV CLOSURE HEAD 0-RING INNER SPACE PIPING ARE NUCLEAR CLASS N-11 AND SEISMIC CLASS I "'Im >- IN ~D> ~ ~ ~ NI o z"'"' g "- 17.lliE /11 SEAL LEAKOFF LINE HAS BEtN RE-PURPOSED AS THE CONTROLLED BLEED OFF (CBO) LINE BY ECR-13-00099. ANY COMPONENT DESCRIPTION OR DOCUMENT REFERENCE INCLUDING

  1. 1 SEAL LEAKOFF SHOULD BE CONSIDERED SYNONYMOUS Willi CBO.

TVsi~G0~s~~f~~ 62 LEVEL INDICATOR ~T".'_4 @RC-V117 Tl TI 961 961A

I___,

TE - RC-V118 961 PT-6~me: .J02MO R62 ~'N ~s oo ~ ~I 9 iG a. gi 15 m m ~ ~ L--------.----------------1 ~ RC-V1D32.I.. c:: g THIS IS A COMPUTER E I RC-V6C l1Rc-V7Cf:2 ~~~E~~~~~ ~:~~~~A~~v xeNu~e':!e ~ 1.::~ '."~""" .'-~;,-; 1 REACTOR COOLANT SYSTEM FLOW DIAGRAM A TMl-1 302-650 62 REFERENCES 2

IF L.. - ... _,I I* .,,( ~ O* l" ~~ -~ '....... A ,.... ~.11* .. ~__!.~ ----_'.;:. -..... tr,_..i**~. I "fll.. l t,.,.,_,,'"Cl* ~-.* '.L ~ ; .... ~ .... ~: j. ~ \\~*... ~~*

  • ~~~~

...... t"::."!-tn.::=.!.'.>r* 1

"*...:ii:: ~~;_': --,..,,.Of#,..

!.. 1..J...;.. *.;:'! ~:- ~ '.~-,~*.*.,.;.~.... ~..... ~,.....

    • _~:{~;~~-.~-* ~:i~{'.... ~ l
  • !!. !'--... ~~~I!?,;*\\<<,~-*

';,_._"';:-:i::t1".:.!.I..__... tt ~ ~~-~, .. t, ft;':~ ;,*s_: I ,, ~1=)~~*~.~ *:.~d-~ ~ t-4,,..~,.

  • ~.r:*..: '.. ~ ::-:..,........ ~-..... ~

'~1.'!'l~.;;'J: *"q!'-~~ ~;--.

  • -:.:..::.'::if'.* ~"~\\w..,-. ;J\\o" *
  • i **-;; !;'ii._;';;,"!~~-<:.... :-:. ~

.. r.. L:-."""'2i ** n* 11....., r .....,~:-.a..:-._i:~..,.,_,'l '"""*,,....,... J.O . * \\- J. ~- *-- *\\'. ... l"'"* "' ~......... ... "~* -C:llt",11 .:._,.. o: 't,t'#lll..

II_~~

...... ~ .........,_.t - ... ~. ~-p-!,."".J-~~ ~~"-' w lo'....,.: ol -~-4* * .r<.o.*..... *~ REACTOR COOlANT SYSTEM G 0 ~ I I A

8 7 6 5 4 3 2 ~i

1,.
~,

~u* h~~ H G F E o e REVISIONS REV. ZOt£ l:iESCRIPTION I ~ I NlA I=~n~I~~~J~?,"~~~CNS~~~~T H I-Gi I I- ~1 F RC-VI202 RC-V I 206 .-1 J FILL ~ 112-RC-v I20J 3/"- RC-VI207 3/'" T FROM LTIOJ7/IIJ8 RC-V1219 2500-3 2500-. 302-650 (C*~l In" 00 N-"'-l I N-'.S-l T ~-.. 2500-3 CCCNlENSATEI' 1/2" RC-Vl~ 3/'- RC-VI20' 1/2" I" I" In" RC-VI208 3/..' RC-VI209 1/2" 'IClNlENSATEI' I-Re-VI21! ~ J POT I. 302-650 IF-!l 302-650 IF-2) \\1 POT I. I FILL FILL E

CONN,

~ ~ RC-V1199 RC-V1201., TE ~ r-1033 1034 ~ I RC-V1198 RC-VI200 I 3/." 3/.' I I I It- ~-+- CCCNlENSATEI\\ FA,.. OC-H FROM RC-T-l 1/2" 'ICCNlENSATEl' -+-~ NOTES LT ,I POT 1/- 30,..00 IG-6) 302-6150 {G-'l \\1 L LT '033 POT 1. VALVE POSITIONS SK1WN F~ REFERENCE CN.Y. I I ACTUAl... POSITICH> CETERMH£D BY PROCEDl.RES. I I 2. ALL INSTRU£NT TAG f'Uol8ERS AAE ~I)(£o BY SYSTEM OESIGNATCR IN..ESS OTl£lNlSE NOT£O. I 1/2" 302-~O lo-al 302-640 (0-81 ~ I I I 3. FCR I\\OT£5,o\\Kl REFEREN:;£S SE£ OWG. 302-650. 0 I I I I ~-~- " LT -~-~ '030 1036 "A" CHANNEL INSTRUMENTS "8" CHANNEL INSTRUMENTS l-e l-II ~ CAD fILE, \\/IE,220.21,1001,OO'-.~Ol c.I 0 THIS IS II CCH'UTER GEI'£RATED O'IIG. 00 l't:IT REVISE IT KAtf.JAl.LV I\\) I 81 ~ ~ITZlCa 03/19/93 0il!I NuclearI GAl ~~~_ .J.t~~;E REACTOR COOLANT O£CK-'!l<: /7 #.4 DATE FLOW DIAGRAM A L1;.:;lGN LEIlUt.R DATE 3 302-003 COMPONENT L SVs 10 INDEX Ef\\Glo'£ER DATE ~~lr I I~>. ~. 302-65 I I, OH 1"5' 2 302-002 SvteOI...S INSTRlJIoENTATI()\\l loIANAGER APPROVAL DATE 302-001 SVIolBOLS FLOW DIA~.fJoI SCALE. NONE OWG. N). TITLE ENG.MECH. A I"~ REFERENCES

I 8 7 1 6 I 5 4 I 3 I 2 I 1 H G ii-F 'E I I jD le n ~ h-i r;,. v I 'B I I ~ I IA 3/4" RC-VlOOA EAST REMOTE LUBE OIL FILL STATION TANK RC-T-3 3/4" RC-V100B 1" 00 RC-P-18 LOWER RESERVOlt 1" OD UPPER RESERVOIR 1" OD GP-150-T131 IGP-150-1 1" 1" HOSE 2" LOCAL FILL 3/4" BREATHER CAP (TYP) 0 GP-150-1 RC-T-4 I ~~ n ,------------------1 I I ~ I I 1/4" I I I I l I [A£:-1](1SPOT SWITCH) I I WEST REMOTE LUBE OIL FILL STATION TANK RC-P-10 LOWER RESERVOIR} ...__ UPPER RESERVOIR --- __________ _J I I I I 1/2" TE1 53 3/4" A ~ ~ ~~1 J&1$i~8~) RC-V125A 1 1 /2" I LUBE OIL FLOW RC-V126A RETURN 2 1/2" TOwlffcf?c~~'i; #':1°* 302-610 (B/D-10) ~RC-C-1A ....J..;-o u,,,-' ooZ 0 ~z '- mg e ~BJ s a.>-ID

i~c!i 0

0 n 1" OD i§J RC-V105A RC-V104A OIL DRAINS FROM RC-P-18 1 1/2" [ 1 1/2" RC-V127A 0 I 0 ~ __ ~HI ~[FS-6] '\\I} RC-P-1A ~~ir~~lF5~2 (FA\\, "IJLo LUBE OIL FLOW RC-V137A RC-V114A HOSE RC-V138A I L __ 3/4" --_ -1! ___ ~~LO UPPER GEARING t=; 5 TE2 L. 0 cf~XEFT~oiR 55 120 GALLONS 0 6 GAL. = 1" IN ( ELEVATION 9000 HP REACTOR COOLANT PUMP MOTOR TE!\\ ~I I 5!,J --w I r-----J ~,, l...MQlli!Q!U I I I I I _J ~MAT~ MOTOR __ fM1SJ C 1- ~gLJ~~gb~~~ -;---r+/-J I 1 1 /2" I tEITHER I l _ _J L __ -----, RC-S-1A I I I I I I I I I 1 ~ MOTOR CONTROLLER (CUSTOMER) ~c 1 1/2" I I I I L r------- cr1wti 1,13/4" I I I I - -t::£j I RC-V136A I I I 1 1/2" I I I TO UPPER BRG. CLG. TO UPPER BRG. CLG WATER CONN #1 302-610 (~/[)_-:@ RC~C-2A 2 1/2" I I I I I I I I 2 112"1~~;:~1gots~l~10) 1 1/?.." ~-- PUMP TRIPPED OIL RESERVOIR RC-T-9" Hl-TA c I I I I ) ) I I I )))//// / / / / / / / / / / ( ( ( ( ( REACTOR COOLANT PUMP MOTOR SWITCHGEAR (CUSTOMER) TEMPI RELAY I (49X) - -} NO CONTACT TO SWITCHGEAR OF OTHER 1HREE REACTOR COOLANT PUMP MOTORS (TO CORE LIFT INTERLOCK) - -} NO CONTACT TO SWITCHGEAR OF OTHER THREE REACTOR COOLANT PUMP MOTORS (TO CORE LIFT INTERLOCK) RCS COLD LEG TEMPERAURE (CORE LIFT INTERLOCK) REACTOR POWER LEVEL 30% POWER PUMP ICCW FLOW (LO) PUMP SEAL INJECTION WATER FLOW (LO) COOLING WATER FLOW TO AIR COOLER (LO) UPPER BEARING OIL LEVEL (LO) LOWER BEARING OIL LEVEL (LO) I I I I L - - - - - - BACKSTOP LUBE OIL FLOW (LO) L - HP LIFT OIL PRESSURE (LO) ,------_J L -

  1. 1 SEAL 6-P (LO)

I I HEATER _J CONTROLLER (CUSTOMER) OIL DRAINS FROM RC-P-1C 302-552 SH. 2 (A-4) - _[]§] ---r+/-J

  • RC-P-1A--- RC-T-9 RC-P-18--- RC-T10 RC-P-1 c--- RC-T11 RC-P-10--- RC-T12 OIL DRAINS FROM RC-P-10 RC-V1138 302-003 302-002 302-001 CiWc.-NO.

REVISIONS 4 IVARIESIREVISEO TO INCORPORATE ECR-14-00092 REV. 0 INSTRUMENT NUMBERS RC-P-1A RC50-TE1 RC50-TE2 RC50-TE3 RC50-TE4 RCSO-TES RC50-TE6 RC51-TE1 RC52-TE1 RC53-TE1 RC54-TE1 RC54-TE2 RC55-TE1 RC55-TE2 RC56-PS1 RC56 PS2 RC56 PS3 RC56 PS4 RC56 PSS RC57 FS1 RC57 FS2 RC58 FS1 RC58-FS2 RC59-FS1 RC59-FS2 RC60-LT1 RC60-Ll1 RC61-LT1 RC61-Ll1 RC62-LS1 RCVT-76A RCVT-76B RCVl-76A RCVl-76B RC65 PV1 RC66 Pll RCVT 147A RCVT 148A RCVI 147A SERVICE RANGE UNITS RC-P-18 RC-P-10 RC50-TE7 RC50-TE19 MOTOR STATOR TEMPERATURE (cu RTD) 0-200

  • c RC50-TE8 RC50- TE20 MOTOR STATOR TEMPERATURE (CU RTD) 0-200
  • c RC50-TE9 RC50-TE21 MOTOR S1ATOR TEMPERATURE (CU RTD) 0-200
  • c RC50-TE10 RC50-TE22 MOTOR STATOR TEMPERATURE (CU RTD) 0-200
  • c RC50-TE11 RC50-TE23 MOTOR STATOR TEMPERATURE (CU RTD) 0-200
  • c RC50-TE12 RC50- TE24 MOTOR STATOR TEMPERATURE (CU RTD) 0-200
  • c RC51-TE2 RC51-TE4 TEMPERATURE INLET AIR TO MOTOR (TC) 0-100
  • c RC52-TE2 RC52-TE4 LOWER RADIAL BEARIN_G TEMPERATURE (TC) 0-250

'F RC53 TE2 RC53-TE4 UPPER RADIAL BEARING TEMPERATURE (TC) 0-250

  • c RC54 TE3 RC54-TE7 UP THRUST BEARING TEMPERATURE {TC) 0-250

'F RC54 TE4 RC54-TE8 UP THRUST BEARING TEMPERATURE {TC) 0-250 'F RC55 TE3 RC55 TE7 DOWN THRUST BEARING TEMPERATURE (TC) 0-250 'F RC55 TE4 RC55 TES DOWN THRUST BEARING TEMPERATURE (TC) 0-250 'F RC56 PS6 RC56 PS16 PRESSURE OIL LIFT PUMP DISCHARGE 240-3000 PSI RC56-PS7 RC56 PS17 PRESSURE OIL LIFT PUMP DISCHARGE 240-3000 PSI RC56 PS8 RC56 PS18 PRESSURE Oil LIFT SYSTEM MANIFOLD 240-3000 PSI RC56-PS9 RC56 PS19 PRESSURE OIL LIFT SYSTEM MANIFOLD 240-3000 PSI RC56 PS1 RC56 PS20 PRESSURE OIL LIFT SYSTEM MANIFOLD 240-3000 PSI RC57 FS3 RC57 FS7 REVERSE ROTATION INDICATOR FLOW 12,7 23 GPM NO FLOW 7 19 GPM RC57 FS4 RC57 FS8 REVERSE ROTATION INDICATOR FLOW 12,7 23 GPM NO FLOW 7 19 GPM RC58 FS3 RC58 FS7 OIL FLOW THROUGH. COOLER (RC P 1A/D) FLOW 12,7 23 GP~A NO FLOW 7-19 GPM RC58-FS4 RC58-FS8 OIL FLOW THROUGH COOLER (RC-P-2A/D) FLOW 12,7-23 GPM NO FLOW 7-19 GPM RC59-FS3 RC59-FS7 OIL FLOW BACKSTOP LUBE PUMP FLOW 0.4-1.8 GPM NO FLOW 0.24-1.28 GPM RC59-FS4 RC59-FS8 OIL FLOW BACKSTOP LUBE PUMP FLOW 0.4-1.8 GPM NO FLOW 0.24-1.28 GPM RC60-LT3 RC60-LT7 OIL LEVEL-UPPER RESERVOIR +/- 3" INCH RC60-Ll3 RC60-Ll7 OIL LEVEL-UPPER RESERVOIR +/- 3* INCH RC61 LT3 RC61-LT7 OIL LEVEL-LOWER RESERVOIR +/- 3" INCH RC61 Ll3 RC61 L17 OIL LEVEL-LOWER RESERVOIR +/-.3" INCH RC62 LS2 RC62-LS4 COOLER LEAKAGE WATER DETt:.CTOR ELECTRODE TYPE RCVT 77A RCVT 79A HORIZONTAL VIBRATION RCVT 77B RCVT 79B VERTICAL VIBRATION RCVI 77A RCVI 79A HORIZONTAL VIBRATION INDICATOR RCVI 77B RCVI 79B VERTICAL VIBRATION INOICA TOR RPM RC65 PV2 RC65 PV4 PRESSURE CONTROL VALVE OIL LIFT SYSTEM PS1 RC66 Pl2 RC66-Pl4 PRESSURE OIL LIFT SYSTEM a 5000 PS1 RCVT 1478 RCVT 147D HORIZONTAL VIBRAllON RCVT 1488 RCVT 148D VERTICAL VIBRATION RCYI 1478 RCVI 1470 HORIZONTAL AND VERTICAL VIBRATION INDICATOR NOTES: VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2.

ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGN A TOR UNLESS OTHERWISE NOTED.

3.

SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2.

4.

TYPICAL OF 14 LUBE OIL LINES ORIGINIATING AT THE LUBE OIL MANIFOLD SIX LINES SUPPLY THE DOWN THRUST BEARING AND EIGHT SUPPLY THE UP THRUST BEARING. THE FOLLOWING IS TYPICAL OF EACH LINE (ONE FOR EACH BEARING SHOE~8E~ORl~R~~bE

5.

ISA TYPE J THERMOCOUPLES FOR MONITORING DOWN THRUST BEARING TEMP.

6.

OIL FROM FORWARD DIRECTION OIL SKIMMER ON THRUST RUNNER.

7.

OIL FROM REVERSE DIRECTION OIL SKIMMER ON THRUST RUNNER.

8.

LUBE OIL TO BACKSTOP (ANTI REVERSE ROTATION CLUTCH).

9.

ISA TYPE J 1HERMOCOUPLE FOR MONITORING UP THRUST BEARING TEMP. 10 ISA TYPE J THERMOCOUPLE FOR MONITORING UPPER RADIAL BEARING TEMP.

11. ISA TYPE J THERMOCOUPLE FOR MONITORING LOWER RADIAL BEARING TEMP
12. 10 OHM RTD, EMBEDDED IN MOTOR STATOR WINDINGS.
13. ISA TYPE J 1HERMOCOUPLE FOR MONITORING AIR INLET TEMPERATURE.
14. HEAT EXCHANGER LEAKAGE-ELECTRODE TYPE LEAKAGE DETECTOR.
15. INSTRUMENT NUMBERS IN BRACKETS AS

[FS-1 J ARE ALLIS-CHALMERS DESIGNATIONS.

16. SEE DWG NO. 135751E FOR PROCESS AND INSTRUMENTATION SYMBOLS
17. SEE ELEMENTARY DIAGRAM 6.9 KV SWITCHGEAR (FOR RC PUMPS) DWG N0.135854E
18. FOR REACTOR COOLANT PUMP INSTRUMENTATION SEE DRAWING NO. 27617F.
19. ALL COMPONENTS WITH SUFIX "A" ARE FOR A PUMP MOTOR (SHOWN). PUMP MOTORS B & D HAVE SIMILAR COMPONENTS WITH SIMILAR COllAPONENTS WITH RESPECTIVE SUFFIX. FOR PUMP C SEE DRAWING 302652 SH. 2.
20. PER S.U.&T. 1 GALLON PER INCH IS FROM -3" TO O" ON SIGHTGLASS.

H G F E D c 0 21 *,,~~~tt*~~~3s ~~60ro~~E~NTsT~0uN~EENclg~N~rct5NjQ~ A R~-~c:_-;:;~iBP1 Hf2 H~2 Hf~E P\\~sEPARE". I ~ COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYM80LS FLOW DIAGRAM TITLE REFERENCES Cad File Name :302652 51 R4 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY en Exelon. Nuclear REACTOR COOLANT PUMP MOTOR LUBE OIL SYSTEM RC-P-1A,B, & D I A FLOW DIAGRAM TMl-1 302-652 4 SCi'.LE' NONE 8 I 7 I 6 I 5 4 I 3 I 2 L ___________________________________________________________________________________________________________________________________ _J

G 10 3 r.. 02-590 (C-7) 1 TO 12" VENT HDR.-PT5 1/2" TO SPENT RESIN TANK 302-691 (F-1 BLEED TANK 302-690 (E-6) rn woL.=-072 PRESSURIZER LOOP 302-671 (H-4' SA~lPLE RETURN r FROM LITHIUM HYDROXIDE PUMP b, SEE DWG. 302-671 G-4 1/2" DI I 302 670 (E 6) ).--- FROM HYDRAZINE PUMP r 1/2",..-. .302-670 (E-6) I I c B A L __ _ FROM BORIC ACID ~ 302-670 (D-3 FROM DEBORATING DEMIN I 302-692 (C-10) t: IE> MU-V49 10 MU-V211 3" OUTSIDE C0~1P. 2 1/2' 3/8" S-111 MU-V166A 9 MU-V6A (NOTE 12) --0 .-1 2 1/2" ~~--'-----,I L ___ _ MU-V8 MU-V54A 3/4" 3/4" MU-V9 MU-V166B (NOTE 13) MU-V115 MU-V204A I SEE NOTE 3 I I 3" 2 1/2" 9 1" 2 1/2" 8 SIGHT GLASS Fl-285 4 TO VENT HOR. 302-690 (C-7) 7 3/4" S-1 I S-11 MU-V105 ! ! z"__, 4" ~.5 SEENOTE3~ 2 1/2" MU-V6B MLI-V70B (NOTE 12) 2 1/2" F.C. --0 -1 ~~-~~I 2 1/2" 1 MU-V110 MU-V204B I SEE NOTE 3 I MAKEUP & PURIFICATION FILTERS 2 1/2" MU-V150 S-1 S-11 :t MU-V55A 2 1/2" 3~~:V56A ¥

-1

~ 3/4" I I I I '1~7 FLUSHING ] ~ ,... v'1s2 !__£, CONN MU- ~"&1 DELAY s: :::i 3/4 COIL~ 1~~Ess CALIBRATION TAP MU-V161A _...__ RM L1; MU-V151 ~ CALIBRATION ) 1/2" ~ls-111 TAP MU-V1618 MU-V160B .~ MU-V57A 2 1/2 rolro ~~

b'.:

,~ ~Ji g y 6 MU-V109B MU-V98 2 1/2" 1 1/2 I MU-V99 2 1/2" BLOCK ORIFICE 1: rMU1\\ ~ E.D. F.C. ,f MU-V978 MU-V5 (NOTE 9) R 2 F.D. TO VENT HDR. PT-6 302-690 (C-7 Fl 142 L SIGHT [t> GLASS 3/4" MU-V109A RB 4" ~m I" cW =i5 e

ou ml 1"

25g:; 'f e:~ g 2" 4" MU-V101B 4" 3" 1 1/2" 4" ---~=~I=--------~*:" --------"+i MU-V104 SEE NOTE 3 4"- - I MU-V48 I ~ I I DRAIN :Lr I MU-V47 I 4" MU-V46I MAKEUP I S-111 S-1 ,1, I 1" TANK I I MU-T-1 I I MU-RV-1 (SEE NOTE 16) I SEE NOTE 3 I 1" I L _1~1~ _____ _________ _J 3/4" MU-V225 1" rt> i 1Mu-v226 ~ N-3 s-11 j c,s-11 TO VENT HOR. PT-6 I 2,. 2., GP-150-2A GP-150-ZR < 302 690 (c 7) I i 8 7 302-694 (G-5) TO WASTE GAS COMPRESSOR 1" 6 5 ,---V~T-1 1" ~ 0 I 1" 5 AUX. BLOG. SUMP 302-719 (C-4) 4 MU-V26 (NOTE 10) ISO. TEST 3/4" S-1 I S-111 RB I LETDOWN COOLER MU-C-18 I g DRAIN 302-719 (0-8) NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. SYSTEM DESIGN BASIS -

SEISMIC CLASS I.

5. VALVES MU-V1 THRU 39 BY B & W.
7. SYiT~~GC'tA~6~ioRNE&Uf~E~E8C~slfiR ERECTION ONLY)

INSTRUMENTS & INSTRUMENT LINES - CLASS C OPEN ENO VENTS & DRAINS COMMERCIALLY CLEAN @ RESIN ADD - SEE DWG, 302-670 (0 RECLAIMED WATER - SEE DWG. 302-670 @ NUCLEAR SERVICES - SEE OWG. 302-610

8. VENT CONNECTIONS ARE CAPPED WHEN VENT RIGS NOT IN PLACE.
9. SEE OWG. 302279 SHS.1&11 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 10.SEE DWG. 302279 SH.2 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 11.SEE DWG. 302279 SH.3 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 12.SEE DWG. 302279 SHA FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 13.SEE DWG. 302279 SH.9 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 14.SEE DWG. 302279 SH.10 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 15.SEE DWG. 302279 SH.1 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 16.SEE DWG. 302661 FOR ADDITIONAL SYSTEM PIPING TO THE MAKE-UP TANK.

4 3 MU-V138 3/4" 3 TO VENT HDR. 302-694 (G.:.6) 1 1/2 2 VENT _3/4" MU-V154 2 1/2" MU-V113 MU-V96D 302-003 302-002 302-001 MU-V178D 1" COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 2 1 47 IC,D,E-21 REVISED TO INCORPORATE ECR-13-00237 REV. 1 1R.C.SYSTEM LOOP"B" 302-650 (A-3) COLD LEG MU-V184A R.C. PUMP A [~ MU-V183A SEAL # 2 SEAL INLET PRESSURE MU-V184B R.C. PUMP B [~ MU-V183B SEAL # 2 SEAL INLET PRESSURE l" MU-V184C R.C. PUMP c [~ MU-V183C SEAL 2 SEAL 1" MU-V184D R.C. PUMP D [~ <Rll> MU-V183D SEAL # 2 SEAL INLET PRESSURE MU-V176A R.C. PUMP 302-650 CONTROLLED E3LEEDOFF MU-V176B R.C. PUMP B 302-650 (B-7) CONTROLLED BLEEDOFF MU-V176C 302-650 (8-4 CONTROLLED BLEEDOFF 1"_11/2"((!ill R.C. PUMP D 302-650 (D-4) MU-V177D MU-V330 CONTROLLED BLEEDOFF D c w R j Cad FOeName:302660 R47 I§ G~~~R~TEAD ~i~~~R Do I ExelonlP NOT RE\\'lSE IT MANUALLY Nuclear MAKEUP & PURIFICATION FLOW DIAGRAM I A 302-660 I 47 SCALE: NONE _ _______ _J

r~---*--* -- -2~~****

I i "I

, f . i

I

' a! I l Fj I i I £I I i 10

            • -*r*--*

I I H G F E D c B A 8 I 7 I 6 I 5 l 4 I 3 I 2 I REVISIONS REI/I ZONE I DESCRIP110N PENET# 63 O,E-J,4 REVISED TO INCORPORATE ECR 14-00032 REV. 2 323 2 1/2" ~2~1~/2~* ~~;;;;;;;;:;;;,;;;;;;;;;;;;;;;;;;;;;;;;;;;;;m;~-<ffi> ______, 3/4" PENETH I MU-V219 3 4* H 2 1/2" 'MU-J6' Fl 4" 321 2 1/2" I 0---------.... c::i----~ MU-V205~U-V206 1" ISO TEST I MU-V107A MU-V221 t P~MP 21/2" I ~~& ~ ~-- ~ I J J "*L.< 2 1/2" ~ MU-V217 11" ' 3/8" OD MU-V118D 'z;> 2 1 /2" ISO. TEST 0-c::i------.... f'- I 3/4" MU,V1078 MU-V220 MU-\\117 3/4" ~ (NO~ 5) MU-V91B 2 1/2" ES V~~38 RB .._MU-V207 MU-V92 1 1/2" MU-V18 MU-V91A (NdJ 7) DRAIN & MU-ISO.TEST V1758 1 t/Z" MU-V196A MU-RB V175~A~-=J-----.:1*1~/~z*.* --~~-~~ ... ~~c~~~~tt;> MU-V90 2 l/Z" MU-V197A MU-V194A z, z" z 1/2M 4~ PE1ET# t 1/2" Mu-v11s V1M7usC


()ioiloC;:)lmCJ-i.... l)l:)o.-..i~--O&Jo--i()ii-----------..~

MU-V32 Mu-vase I Mu-v2a \\l.:.o~~--i~~~~~*~~o~~~~Q F0 FC ~ (NOTE 5) MU-V194B MU-V197B 314,, (NOTE 6) J/4" 11(:8'.)ii(J-!-[Dlllii""!"<J--.-... l 2 1/ 2" MU-V146 MU-V145 0 LJ G F = [J> TO CORE" FLOODING TANKS 1.. ~~ < 302 711 (G 1) I TO CF-V11 FROM MAKE-UP & PURIFICATION FILTERS /,, MU-V78 MU-V79 I 302 660 (C 7) ) 2 1 2 N FILL LINE <fTu> ~ TO UPSTREAM OF N-31 N-2 SEAL WTR. RETURN ES COOLERS ~ 2 E~ < 302-660 (D 5) I MU-V36 4" VENT TEST RB MU-V144 2,, 3/4" ISO. 1 1/2" 1,. 1 1EST E MU-V75 2 1/2" ~ 00 T ISO. TEST 1';/4" rMU-V147A ~ MU-V77A 4.. MU-V778 4" I<- 2" f> ~ MU-V37 ~ 2" FROM NITROGEN SUPPLY F R n tMU-V193A -- ~~ur.i - ~-U-V193B MAKE-UP & 2" 2* PURIFICATION MU-VH7B I D MU-L___tl?\\ 1;2*r_fF2\\ PUMPS ~ 100 PSIG I 302-720 (C-5),I 3/4" FROM Nl-V22 f> FROM HYDROGEN MANIFOLD 302a__-7~~ ~~~7),.J 3/ 4" GAS SAMPLE SEE DWG ~ 302-671 CE (F-4) 117 m y 3/8~ 3/4" V230 ~ ~ 12" 4., RB T MU-V64C ISO.TEST 1 1/2" "~ WI ....I 0. 9ofD-o ~a_ I v~~B I ~~§ = 1/2" ly 1 1/2" 13" NOTES: ,_ g ~ t I

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

~o ~ \\Ml ACTIJAL POSITIONS CONTROLLED BY PROCEDURES. EC 41 1~ ~

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY s~

~

w.

MU-V111 SYSTEM DESlGNATOR UNLESS OTHERWISE NOTED.

I(/)

L - ..J L - _J

3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN 81 ~

THE APPLICABLE ENGINEERING SET POINT DATA BASE. c:: I 8

4. SYSTEM DESIGN BASIS-SEISMIC CLASS I.

1 MUFcV28 ~ 1 ~ s" 6° 6!'

5. SEE owG. 302279 sHs. 1&:11 FOR INSTRUMENT AJR DETAILS EC ::ii:

TO VALVE OPERATOR ~ w I EC

6. SEE DWG. 302279 SH. 7 FOR INSTRUMENT AIR DETAILS

--- 1 MAKE-UP TANK Qlw MU-MU-MU-TD VALVE OPERATOR I §I~ I V72A r V72B r V72C

7. %E ~A~vE Jg~t~~Tg~* 9 FOR INSTRUMENT AIR DETAILS

.M.!.L=.I=.J.. I - I f,12 I I :,13 I I [,14 I

8. SEE DWG. 302662 FOR PUMP CONNECTIONS AND AUXILIARY EQUIPMENT.

(SEE NOTE 9) I [ I I I I [

9. SEE DWG. 302660 FOR ADDJTJONAL SYSTEM PIPING TO I

I I I I I I THE MAKE-UP TANK. 3/4" 1 L ________________ J L


~

L


~

L ~I ~ -W I 6,. 6.. MU-V249 MU-V68A MU-V69A MU-V69B 302661_R63 4" ~m ~ ~ OUTSIDE MU TANK ROOM I 6" M MU-V14B I-c n 0 ~ ~ L _!N~!.D~M~.I_A~ ~O~- _ 1N-2 LIQUID SAMPLE I ~ '{/ N-3 SEE DWG CE 3 8" 3 4" 4" 4~ MU-Vt12 ES M MU-V14A 4" iN-2 t::i 302-611 120 A _ A I ~~Ir') ~..... (F-4) MU-V45A L _________ ~-J MU-V12 lli ~g4_ ~2 r--~~~-.--~~~~~~~~-1~ ,,...... <~ r') <Cffi <(CJ 0 w 0 11,. FM ~~~ J,~8 ~~~ ~;!) z N-3 N-2 -; ~; ~~ ~§l g ~ ~ yt T ~ ~~ ~;g: ~~ n (/) I"") ~ MU-V44 (/) N mo

i;O F

g ~ti) ~~ TO AUX. BLDG. SUMP 2"

=

f:: 1,1.. 3 302-003 COMPONENT & SYS ID INDEX 302-719 C-4 5d J, 2 302-002 SYMBOLS INSTRUMENTATJON z~ 1 302-001 SYMBOLS FLOW DIAGRAM NO. DWG. NO. Till.E REFERENCES 8 l 7 I 6 I 5 i 4 I 3 I 2 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY - MARJ< TETKOSKIE 11/11/15 ~4 4,;:; I UESIGll~ llAlE '"" ~ EMbi. Nuclear MAKE-UP & PURIFICATIONt-- FLOW DIAGRAM I A TMM I""" 302-661 r 1';;'3 SCALE: NONE

iA NO.

I

8 7 6 5 4 3 2 REVISIONS DESCRIPTION COOLING WATER NOTE 7 H 1" 1" o IN/A I NEW DRAWING PER ECD~C301003 H '£1 G E D c F NUCLEAR SAFETY RELATED 1/2" y NOTES 1 VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. ,3 SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2 4 SYSTEM DESIGN BASIS-SEISMIC CLASS I 5 PUMP MU-P-1A SHOWN. TYPICAL FOR PUMPS MU-P-18 AND 1C 6 SEE DWG. 302-661 FOR PUMP SUCTION AND DISCHARGE CONTINUATION. 7 COOLING WATER FOR' PUMP AIC FROM DECAY HEAT CLOSED CYCLE COOLING SEE DWG 302-645. PUMP 8 FROM NUCLEAR SERV1CES CLOSED CYCLE COOLING (0.) SEE DWG 302-610. ~ Cad Fie Name 302662 RO m _ ---.J ~ ~ 2 t/2" 1/2" 00 700 HP MOTOR COOLING WATER NOTE 7 1 MU-e4A MOTOR AIR COOLER 2 1/2"I I 1/2" ~ 11/2"OD 3/4~ 00 MU-VZ34A 1/2~ r/Z" P/8" P/8" GEAR BEARING BEARING SPRAY NOZZLE NOZZLE NOZZLE (EAST) (I'<£ST) GEAR UNIT (3.8 TO I) 3/4" 1" SET 26 PSI MU-V243AjIlI~ 3/4" GEAR LUBE OIL SYSTEM 3/4" 00 3/4" &Y INSTRUMENT NUMBERS I.4U P lA MU P 18 MU P Ie MUP2ATE1 A0742 MUP2BTE1 A0751 MUP2CTEl A0760 MUP2ATE2 A0743 MUP2BTE2 A0752 MUP2CTE2 A0761 MUP3ATE1 A0744) MUP3BTEI A0753) MUP3CTEl A0762) MUP,3ATE2 A0745 MUP3BTE2 A0754 MUP3CTE2 A0763 MUP3ATE3 (A0746) MUP3BTE3 (A0755) MUP,3CTE3 (A0764) MUPJATE4 A0747 MUP3BTE4 A0756 MUP3CTE4 A0765 MUP5ATE1 A0739 MUP5BTEI A0748 MUPSCTEI A0757 MUP5ATE2 A0740 MUP5BTE2 A0749 MUP5CTE2 A0758 MUP6ATE6 (A0741) MUP68TE6 A0750) MUP6CTE6 (A0759) nco .-.0. (, '>C""n\\ nc- .-.00:> I, '>10-\\ nc- .""7cr I. '>10""\\ 3/4~ MU-V247A MECH SEAL MU-P-1A 9 STAGE CENTRIFUGAL PUMP (CASING) STC I EXIT 1/2" 00 3/4" MECH SEAL 4" roo MU-VI72A 3~ 1/2" 1/2** 1" I I 1/2" I I,., I,., SUCTION DISCHARGE NOTE 6 NOTE 6 &Y 1/2" 00 3/4" 1 3/4" 00 VENT 3/4" 3/4" MU-C-3A COOLING WATER PUMP & MOTOR LUBE OIL COOLER NOTE 7 PUMP AND MOTOR LUBE OIL SYSTEM 1" Oil LEVEL ~ ~ I, 1" + 1/2" + 1/2" I ':::;'1"-=-"":~ u-- -,:- --t--:------------------------------------------ D B G F c E THIS IS A COMPUTER ~ __ I I MV-"'-;:>-"'O" \\L':'OOl I MV-..... -.. 'oo \\L"'-O/Vl I MU-'.:>-"'O,", \\LL<JU-'J ! GENERATED DRAWING DO \\ GPU NOT REVISE IT MANUALLY .UCL.AII / GAl 1 ~~";D'CE D' ';~9 MAKE-UP & PURIFICATION A %-<.-0..-~-~; MU PUMP AUXILIARY SYSTEMS A 01:_ ~ .r.v.:~ O\\O'G, NO FLOW DIAGRAM SH Il(~. 3 302 003 COMPONENT & SYS 10 INDEX q h..d r*~9f I' 302-662 I~ I' 0 ~ ~~;-gg~ ~~~~g~~ ~L~r.:UO~;~;~~ION IbkM( ~,:;~, 111*1 SCAl(: NONE NO. OWC, NO TITlE INTE ACING CQtIICURRENCE SA NO REFERENCES 8 7 6 5 4 3 2 ,'5.

8 I 7 I 6 I 1 'I I oJ I I REVISIONS REV I ZONE I DESCRIP110N TO PLANT EXHAUST 8 IH-S IREVISED TO INCORPORATE ECR 07-00005 H lf64\\ )( )( )( H o c E F G I<- I-h, ~' Z 9' I-I- I-SEISMIC CLASS ARGON REMARKS EXP SECT EVAC COND N 2 BOTTLE DEMIN H20 RCS LIQUID HIGH PRESS PURGE W/N2 DEMIN H20 REMARKS Res LIQUID EXPANSION SECT SAMPLING DEMIN WATER SG SG SG SG BY SG SG SG SG I 5~Wsr~~I~* ~~'Pf~~~N SG 1~?:o6~~S(~5P~~gl~~ r1~) SG I HIGtt,~RE~¥R6~~~ING SG SG BY SG 'F 70 77 70 70 70 TEMP <650 7D 40 UPSET PSIG I r I TiME DESIGN DATA 2155 PSIG PRESS OPERATING DATA 70 1 25 FLOW 1GPM 10 13 SCFM 1 2250 13 SCFM 1 15 (NOTE 7) I 5 20 LITER/MIN 1~~IlTOH~ ~~ 4 IATMOsl 100 3 IT642~ I 150 5 1 2250 I 70 12500 I 70 616000170 2 1 100 I 100 1 I 2500 I 650 I#) NORMAL I PSIG r uo 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE. NOTES 1 VALVE POSITiONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITlONS CONTROLLED BY PROCEDURES. 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWlSE NOTED. o N ICod file Nome: 302573..R8 I~ 4. PIPE AND TUBING MATERIAL TO BE IN ACCORDANCE WlTH SP-90003-201 REV 2 AS FOLLOWS: SYMBOL LINE SPEC WALL THK/SCH TUBING [8> ASME-SA213 GRADE 316 .065 { It> 150-2 40S PIPE ~ 600-2 80S 5. FITTINGS TO BE SCREWED-COMPRESSION TYPE-PARKER (PI) SWAGELOCK VALVE ENDS, RELIEF VALVE ENDS ARE THREADED. 6. PRESSURE LIMITED BY RATiNG OF PRESS INSTR. DIAPHRAM SEAL 7. BAUVBA~cfB[~O~T(~I~§I~ ~~J~§T~C~~.X ARGON FLOW

8. * -DENOTES VALVE HANDWHEEL EXTENSIONS.

FROM CA-V384 302 671 (0 5 TO CA-V385 302-671 (0-7 ~ 3/8" 00 ~ 3/8" 00 4 -v 1 .A .~ I I 3/8" OD I I" CA-V328 'j I Q SEE I W NOTE 31 I I I I I I I I I I I I 1 CA-V324 n* I I I I CA-V325 I I ()

  • 3/8" 00 3/8" 00 u~"o.

300 TO 1000 Ml SCH 40 PIPE ~ CA~v329 3jB n 00 I---J 1Jt' [- CA-V327 n TO EXISTING EQUIP DRAIN COOllNG---- BATH I CA-V320 CA-V3~,1 ~ 13/B" OD 6~ C CA-V322e [- CA-V323 ( CA-V310 N G:tJ I L ~~~~~~==~~==~~L~~~J ~1" SAMPLE HOOD ./ ~ ./ ./ ( PT~~~S '" 3 "'l ~A-V332 G* I J m I---~H-w -J-- tD -I~-=====-- I SEPTUM~ 3/8" 00 "f CA-V309 .. "c+/-0 CA-V313 3/8" 00 ... I~ li~3) I( )( )( @------i I I I I I I I 1-I I -cC 3/8" 00 "1" co CA-V319 I CA-V307 4>---- LEAD SHIELD WALL~I ~ CA-V318 SEE NOTE 3 1/2" r-3/8" 00 3/8" 00 I"~ CA-V451 O~ ~ DEMIN WATER FROM CA-V337 302 671 (F 1 I I I, I CA-V326 ( I CA-V312 I TO CA V430 3/8" OD 1 1"L.JlLL,"":'--+--1" CA-V315 <302-671 (E 7) I I 3/8" OD I I b I I ~ I ~C~~O~'~~ --~I-TE-1 023----H ~~ ~ 3/8" 00 ~~-I TO CA-V452 .L <THIS DWG. (A-7) f-------1vf-- CA-V472 3/8" 00 TO CA-V414 CA-V450 ~3/8" L-..f 302-671 (H-7 SET 2250 PSIG PI SET AT 6 PSIG I-------:I-------------------T-;~-=--=-~-=- -=- ~~ -=- -=-~ -=--=-~_l-=-lA-CIC-1001 8 ~~~~$~f~ I I I CA-H2E-100 I I NITROGEN PURGE OUTLET CA-V470 3/8" 00 I I TO SAMPLE HOOD A-"i,"'--=-c)(}----~I_--_f'0_-_;--{)k1_"=-"-....l.--_{XJr_-'----_IH ~I 302-671 0-1 ~ 1 CA-V462 CA-V458 2


J OD~IN.

FLUSHING WTR. OUTLET ~ I TO SAMPLE HOOD I CA-V453 CA-V454 302-671 C-1 I FIC I 2 RCS SAMPLE OUTLET 302-671 H-5 CALIBRATION GAS INLET FiC I CA-V459 CALIBRATiON GAS OUTLET TO SAMPLE HOOD 302-671 (0-1 EXISTING NITROGEN BOTTLE STATION PRESSURE - 6000 PSIG CONTENTS - 494 CU FT ARGON 99.9995% MIN PURITY PRESSURE - 1585 PSIG CONTENTS - 100 LITERS -l B F c D G E CA-RV-46~ I SHml'~ N/A 8 IO~". TMI,1 L-302-673 SCAL.[: N/A AmerGen ~ POST ACCIDENT REACTOR COOLANT SAMPLING A FLOW DIAGRAM ,I,;&;' 01!056~7 h,;;-D1 MARl<; EVERLY SYMBOLS FLOW DIAGRAM TIm POST ACCIDENT REACTOR COOLANT SAMPLE HOOD DETAILS POST ACCIDENT REACTOR COOLANT $AMPLE HOOD BACKING PLATE DETAILS POST ACCIDENT REACTOR COOLANT SAMPLING HOOD PIPING POST ACCIDENT REACTOR COOLANT SAMPLING HOOD PIPING DETAILS COMPONENT & SYS 10 INDEX INSTRUMENTATiON SYMBOLS 302-001 DWG. NO. 304-6791A 301-0301A 304~6801A 302~003 302-002 301-0311A 1,0 I I I, I I ~ I I I I I I I, IJ N CA-V461 3/8" 00 r--.f CA-V464 CA-V452 ~ 3/8" 00 CA-V455 CA-V456 I I I I I I I I IL__ DEMIN. FLUSHING WTR. INLET THIS DWG. (E 7 Res SAMPLE INLET 302 671 (E 7 N 2 99.998% MIN PURITY PRESSURE - 6000 PSIG CONTENTS - 494 CU FT A 8 I 7 I 6 I 5 T 4 I 3 I 2 I

'"I 8 7 6 5 4 3 2 H REVISED TO INCORPORATE EeR 06-00067, REV.O I HI E c D G F 1 VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2. ALL INSTRUMENT TAG NUMBERS ARE PREFiXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED, 3 SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMS2 4 NO SLOPE REO'O.ON THE WELDED PIPING ASSOCIATED WITH PENETRATIONS. 5. SOLENOID VALVES AT PENETRATIONS WILL NOT HAVE MANUAL OVERIDE 6. TIJBING TO BE SLOPED 1/8" PER FOOT MINIMUM TOWARD HYDROGEN ANALYZER. 7 ~§O~~NR ~~~T~IREC~ ~ ~II~ ~bSErfl~~~~.ON

8. NNS IS ABBREVIATION FOR NON-NUCLEAR SERVICE.

NOTES C>- O I Cod File Nome; 302674 RlO I~ -I'- 3/4" ~(NOTE 6) 10 CONDUIT 10 o-~ EL.333'-Y HM-V08A HM-V07A 1/2" 0,0. GP 150-T13 P 150-T13 REACTOR BUILDING GP 150-4 00 N2.S-1 INTERMEDIATE BUILDING GP 150-T13 NNS,S-I GP 150-T13 H' BOTTLE (CALIBRATION) 1/2" 0.0. 1/2" 0.0. 1/2" 0.0 1/2" REAGENT BOTTLE 1/2" ~(NOTE 6) ~(NOTE 6) SlQ.~fjNOTE 6) 1/2" 0.0. SLOPE (NOTE 6) /2"OD HM-VllA HI~" r.U. I 'I'VV 1.. CjJ ~ ***** I 1/2" 0.0. I I 1 2 I I H 2 ANALYZER & INDICATOR B HM-AE-42B H 2 ANALYZER & INDICATOR A HM-AE-42A 3/8" -'--'------'-----'---'L----'L.,00 ~ I.~ 13/8"]/4' 1'/4" 13/8" ~ q 0.0. 0.0. D.O. 0.0 o ~ '"z ~ 6 6 ~ ~I '"zm F' 6 6 ~ D B E c G F REAGENT BOTTLE H2 BOTTLE (CALIBRATION) NUCLEAR SAFETY RELATED 10 302-674 POST ACCIDENT MONITORING CONTAINMENT HYDROGEN IA FLOW DIAGRAM THIS IS A COMPUTER ~~~E~~~~ ~~~~~~A~~A AmerGen SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM


mt:E COMPONENT &

SYS ID INDEX 302-002 302-001

DWG, NO 302-003 I

I A 8 7 6 5 4 3 2

8 7 6 5 4 3 2 R£Y[SIONS DESCR1PTION REVISED TO INCORP(J?AT( FCN-CI06686 H H RC BLEED TAI>I(S ~ ~ MISC WASTE [vAP SEE owe 302-695 ~B ~ MISC R"A.CT E TK "0 CE'0' (1.011 r;;\\ ~ RC WASTl; EVAP SfE QWG (r-31 (r-31 302-69~ Ic;\\ (;'\\ ~, ~ V ~V RC ON TK SEt DWG 302-69<1 ~ ~ I I I IC"'<... 1040 I I Ic...-vl039. ~ IXJ-L.....kxd I I I I IF Ic... <vI037 "'-/1 'I'~I I )ttttttt ~ I 1/2~ 00 I CA-CA-CA-CA-CA-CA-CA- ~-::-~-:- C'- . "03'0 "0'" "0'." "0300. "03'" "om "O'OJ ____l:VIOJIA tV~JIB VIOJIC CA-V!036 G D E I. VALVE POSITIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS on-£RwISE NOTED. 3. SET POINT VALUES F"OR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE CI'IlLY. ACTUAL DATA. CONTROLLED BY GMS2. NOTES 11.2" 00 !C" _1"0" 1/2" 00 1/2"

~~

f u .~ ~ ~ t).\\.. ~ I t."o"O ~ \\ ~! I I ~ ~ ~~ ~ ~T if'- Aif'- I CA-V1034 \\ C... -VI035 "'-/1 C",,-\\l1033 1/2" 00 11/2" 00 11/2" 00 11/2" 00 11/2" 00 11/2" co 11/2" 00 1112" 00 11/2" 00 -I II! ~ 1/2" 00 1/2" 00 \\ 1/2" 00 I 112" 00 I t/2" 00 I I 1/2" 00

Iil I I I I I I

I 1/2" 00 I I 1/2" 00 I 112" 00 ifll""I""I""I"i"I"i" \\ ~ ~ ~ ~ ~!U!U!U!U!L CH'O" ~ "if_ _"if "if_ F E G D BECKMAN H2 -0 2 ANALYZER CA-G-IA '2 '0 BECKMAN H2 -02 ANALYZER CA-G-IB c SEE BECKMAN DWG S751-PE-32467-P-2 SEE BECKMAN DWG S751 -PE-0093-P-5 c A c.lo I\\) I ---'0' -J 01 RI ~ GAS SAMPLING FLOW DIAGRAM Nuclearl GAl CAD FILl:, VIE.552.21.IOOO.OOI-.1201 Jill!> IS A COMPUTFR GENERATED DWlG. (X) NOT REVISE IT M/lJ-.lJALLY TO FL~ OOAIN 0, SPm } I H2 SPAN CALI8J?ATICI'l GAS Jt>LICTS N2 ZERO CA*VIO<l2 1/;:><< 00 mOM ~M,1,-7 DTSCHARGE 302-694 (E6) WASTE GAS DECAY I J 1/2" 00 0;_:~-T~~~6J 1I2~ 00 I/'~ 00 1/2" 00 1/2" 00 CA-VI092 CA-VI030 WASTE GAS {)CAY T~~ 0$02-694 16*5) GAS SAMPLE PANEL SET /IT 5" r WASTE GAS DECAY ~:~-T~~:4) I/g~ 00 SV A7-6 EXHAUS1 MOOO SV-A7 II 1/2" 00 ,~-----,-----~ I (C':8;C1 5V-A7-8 (C3~'JAI SV-A7-IJ 1/4" 00 1/2" 00 SV-A7-12 l~ I Qh) A SVA7-IO PI In!:) TO WASTE GAS C()HPRESSOR INL_E t 302-694 10-2) A B ~.MECH. REFERENCES NO. 302-003 CiJIo'Ptr'lENI '" SYS 10 INDEX Et-Gtf\\EER DArE TMI DWG. NO. SH. REV. I ~ I ~~:~:~ ~:::~~ ::~R~::~ION MANAGER APPROVAL DATE UNI I I

SCALE, 302-675 12

~ T""i""TLE FOR CONTINUATICI'l SEE DRAWING C-302-84 I (REI'" WASTE GAS I>\\ANIFOLO

  • EL 30~')

8 7 6 5 4 3 2

H I

F I 'E I D Ie I I I 8 I 7 I PRESS. SAFETY VALVES 302 650 H 8 MAKE UP WATER 302 669 H 3) 10" I" ~ s sCFpT 323 323 SET POINTS 2PSIG 6 2" I 5 1 4 I 3 I 2 I FROM RELIEF FVRAOV"M, ~EHUEvF37 FROM SEAL LEAKOFFS L~OR~A2'N1IF]R[OM']I:')....l,;...... __ ~2~~AfR9M",A [}1l:VAlt:1VFM~1I-~V1R~n~I.;I~/22*-.... [~~V]'t9": '~~>-,.l;;1-.1 r]RC~P~lA~&~'~B~-2~'*-.1 CORE FLOOD TANK 8 r' ci'-Jut<~r.~"1TI'.UU]c}U;NltK>-...l';;."... ~ )2-660 (0-: 302 640 (E 8) '= 302 650 (A 6) V 302 711 (D 3) IV L 302-: 0-8) V FROM RELIEF I FROM SEAL LEAKOFFS J I I ~~VE6~OH(:6~) 1" _I RC-P-1C & 10 2" I 1" t 2" II WOL~-V524 1" O~:E<iJ!'~:,:)--"'IIoI, 302 650 (C 6) 2" ,1\\iJ~~~36 WOL-V525 ~f DESCR"TlON WDL-V537 2" NOTES:

1. VALVE POSITION SHOIoVN FOR REFERENCE ONLY.

ACTUAL POSITlONS CON TROll_ED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGI~EERING SET POINT DATA BASE.
4. ALL PIPING ON THIS DRAWING IS NUCLEAR CLASS N-3 UNLESS NOTED OTHERWISE
5. ALL PIPING ON THIS DRAWING IS NUCLEAR CLASS N/3, UNLESS NOTED OTHERWISE
6. SEISMIC CLASS AS NOTED 3"

PEN. .Jilll--i---- REACTOR DRAIN PUMP


y--------------------y-------------------------------------------,

~,! ~ ,~~~-NV6~ 3 I THIS DWG (D 8) / I I I I ~* WDL-V253 --;T 3" FROM WDL-V54 1 1 2" WDL-V364 1 1 2" WDL-V404 2 1/2" FROM CO-V162 ~ 1/4" 00 302 693 (G--5)

  • ~ I 5~: I 2 1/2" I ;

302 352 (0 5) I § 1I"'3'-'W4'-'o'DL-&""V1-67-9-rh3'7/8oA"""o'CC0,.. I<II: ......,,I<IIS~ ~~~ I" TO WDL-V315 30F2R06M60MU('-EV~O) 2 1 2" 2 1/2" 3" 2 1/2" 3" ~(-r 3" + WDL!V728 THiS OWG D 6 0,** WDl-V14 WDL-V15 WOL-V16 t-0 S-II S-III ES l.O. CS 55 TO DEBORATING DEMIN 2 1 2"... CP,,* t "CD... 2 1 2" 2 1 2" 2 1 2" AUX STEAM ~ 302 691 (H 5) 21/2" ~ RECLAIMED WATER_ 1 1 2" WDL-V308 _I ~1~O~W~0~~vg)7 2 1 2~ WDL-V3 WDL-V17 WDl-V4 WDL-Y18 WDL-V5 WDL~V19 83 WDL-V.304 MAN. LOADER 3/4" aiL WOL-1I1' 'V376

't80t~DO#

tFR~3~~~~A~0~~~~V9~~39IT::>-..J.J.:1'~'W:::O~L"':V~30:::9:<I-~tf2,;.1/::i2:;."-T-'--L~:!I-SH(~;UI;:bSilll~iE~L-L-----_..::.W:OL;.",:;V2:.....::.W:DL;.",:;VI:.., ~~ 23:/~' I 121/2:'~ 23.. '~~" 121/2:'~ 3'~' ~~-~ =~ S J; NON-NUCrN~ 20 PSI~0~2 ;;OOMB N~-V17 1/2" 3" S-iIIs=ii Ii I I /~ ~bV56 6'.. WO~:LlI:~ 1/21." --.""I"oko...;,2,,.;l.1./2;,."----------,-/2-"--,"'I" ko ..... :..11.. 2.. "_--3"--- GR-EEN---,..1/:-",.:,2'_' """ T ~ i ~ '-..,;i3'.' _r_..j"*CVIilD., __ P.T-.'-. WOL-V381 WOL-V20r~~ 3" WOL-V2~r.::::.. ,,(9i.,2).. WOL-V22 ~ 21/2" 2 1/2" 302 691 (G 8) 1 1/2" WDL-V422 WDL-V421 .w,1 / 2"11 < 302 693 (G 7) I ~ ~ II-3" [J:CZE§:g;::;:G~)i3';" IIofl WDL V55 302 691 G 8 jj, 1>> ~::~~~;2~;ii~;;/~~~:~:::)~~~~':":'2~1".. j.... G"I~.i':;i:;;;-2;l,3 R .... ::~~:9:~f~2~~7~; ~ 12" ~(A-8) ~~g,L~~ ~~ :~-V:4; WOL-V~'0 [FR]O:o:MEM:e:U~-[VI@O;:.:57I:>_.l4:""....... ~'~P~T,;;,i,5"" FROM WDL-T-7A :-;t t lli PT 4 ~I ,:~~~ _____ ~ 6" SO:? 660 (G 7) 302 692 0 9 llLJa 1~ THIS DWG (F 7 .;;......:: _____....il-_______ 6" I 1/2" J t Cf-WOL VI56 FROM WDL-V.387 2" I CATION DEMIN VENT WDl-v655 THIS OWG A 4 OUTSIDE ",I..... d3~02~6g;91~(~H~5~):::>---1Ir-'P:JT:::;;,5.. 302 691 (E 8) 2 l1LJA 1 1/2" FROM WDL V18~~;3 FSHIELD WALL,WDL-V164 ~ WDL-V165 [FRjO:o:MEW1°g;L-~V~3~867I:>_-'2'-"-.Jt! 6" DEBORATING DEMIN VENT 2" ~p;t- ~t, WDL-V342 302 691 (H 7) 5_-11 1S-I_ 302 691 (H 4) ~ rt-'-----'---+ ~ ~ ~


r---

J.. 1£

1 v.I WDL-V340

"

  • 0 WDL-V23

~ WDL-V341 3" [ FRjO~MEc:2FTI-VJ'~8B~,C~>_3~4;." __ ":;'PTliIii\\8-1 FROM MU-K1A,lB 1" 2'" PT 5 /"\\ / \\, / \\, 374 3.... of~J() ______.... ____ ~ 1 ____...... _....... _.. 3.. " _... __ ~ __ ~~~ 302 711 C 5 302 660 G 10) I 6" 6" RC BLEED TANK ~ L.. ____ W_D_L-.T_-_'_A ____ ~J ~ RC BLEED TANK ~ L.. ____ W_O_L-WT_-_'_B ____ ~J ~ RC BLEED TANK ~ L.. ____ w_oL_-.T_-_'_C ____ ~1 ~ WDL-V311 WDL-V312 3" 3" 3" 6" TO MU-V49 302 660 (A-lO TO RC BLEED TANKS THIS OWG (E 6) 2 1/2" S-III~ lli SEE ~ 302-671 @-E ~ __ r1. 1/2 AREA G-2 132 '-- WDL-V188 WOL-V691A SAMPLE TO FLOOR 2 1/2" ~~lS~:6~.D. ~_DRAIN 5~1/2n WOL-V1006 If

9T6 WDL-V.35 1 1/2" e..

2 1 2' WOL V38 tFRjOgMEW~OLL-~Pc~2A"'52B-2io"-----i FROM MU-C2A,2B 3 4" MISC. Rtf~2~g~IVfA~:STE 6" WDL-V313 1 t- , 5-11

  • o,WDL V291 302 719 PT 9 302 660 (D 6)

WDL _ T -2 I 1.3.. "oa(:~J()_...... 'f.. 3"""'I..., WD' <<""" 0 ~~WDL-V691B WDL-V343 WDL- ~ TO C-"<O' '1 2" FROM,," 0"< 0" 1 t SAMPLE Vll 302 692 (G-8) ~ l:l:l-I Mu-rLA,LD 3 4"

6.

I WDL-Ll-207 ... 0,1 ~_I IS-II POINT TO FLOOR 2 1/2 r 302 660 12" 3" ... CD"WDL-V26 3 H T WDL-P* 6A(PX-297} "Z DRAIN 16£ 2 1/2" ~~SS;~Wf.2!,~ UNIT 2 1 1/2" ~ 6" FROM MU-RV-1 2'" PT 6 §n~ 1 3"

  • WDL-V24 I

1/2" 00 ~T: p.;.. iool:vl~~51 1 1/2" 302 660 (A 9) 3'f5 S-' '5_11 I W20L'-~21,008.. 297 ~DL-V36 2 l' "2 ~~~- ~-D WOL V629 ~ ~ J; 'I....... _..jRJ:.~... 4" T-I 5-11 U 1

_~131~~~-NUC WOL~~~65A WDL~~~658 3* 1-WOL-V265C 3" "fB~

f 3" 'I' ~ 'I, ~'C.

9./'

./, CD"" D 11/2" oct::. I I ~' 1/2" -,,;','- I '1/2" WDL-V240 WDL-V713 4" 2" -3; WDL-V167 I v

  • ~iWDL-V27 13 H

~1 1/2" I WDL-V30 t ~ I"'w"'OL"'-Vl-14{J-ii!"""'j'/2" 6" =~, $ ~" S,-lIljS-! '~,~ 'ct - - -I PT-4 SAMPLn ~ FILL

214;2" I ~ W~-V~ ___________ ~

WDL-V28


r--- ~~

wI I I WD~L-V162 ~ 4W~DL-V163 ~ i!o2" rp~~1-~4)~6~ ~THISi OWG D 5


----.---- -.~,~--

- t ~t 3" .,f<- I I FE FE 4" :; " ~rS-11 1/2" 0.0. PT "".... _... _-""'............... ""'................ r.............................................,...-_.............................. iiooal!lIo'l I I 309 4" 308 4" ~ 2 WDL-V1002 294 I I 0, WOL-P-6C L L ~.; WDL-V348 WDL-V349 2"

  • ~

1 1 2" WDl-V346 1 1 2" ~CD~' ~WA 1 1 2" ~3" 3" 11/2" s:. 3 i ""p,r;:! WOL-V6928 1 1/2" r 1/2" (FE\\ WOL-V59

WOL-V6S6

REFERENCES:

WASTEpJ~~~SFER 2 1/2" WDL-V691C WOL-V344 ~~~lE TO FLOOR WDL-P-6B(PX-298) 'Z DRAIN 1/2" O.D ~l WDL-Vl010 fg:DL_V345 2 1 2" WDL-V37 ~ WOl-V13 2 1 2" 2 1/2" WDL-V32 WDL-V33 2 1/2" AIR "n " _SUPPLY~ 1/2 00 "2~TDi WDL-V241 ~ t ~1 1 2" I lf57 1U8 29S 1

- CAUSTIC SOLUT'ON -

SEE DWG 302-670 1 1/2' WOL-Vl004 I I I l~j (D-7) 0/ WOL-F-5 F ci WOL-V182 i::h I

- RESIN ADD LINE -

SEE OWG 302-670 o WDL-V722 (PI\\ 3:

  • .9

.'.'11.i.2.' "-WD~L"V.J3.47~r-~_... ____ ~_[),Q.;,Rl(jo... """.of ~,":*jJ:}oo"- ,'2io*"','... ~_CT[Q0~W~D:§:L-[V(12":50b:::) a ~ ~ 0:+ r-I. 302 691 E 1 CD - CHEMICAL ADDITION - SEE DWG 302-669 H G I-F E D I-c I~~;; @--7P3iO ::=r-1/2" ~v,~ENT."',,'I WDL-VS7 WOL-P-7~~~2:~9~,... 6~~~00R ~ 1 1/2" ~0-2R I r 1 1/2"

g2W~~~V~6~

~ = :;:~~e:::DSD~~I:E: ~ SSEEEE :;'G 330022~66;04 i N .J 1 1/2" F-@1/2" FE ~1 WDL-V60 IWDL-V657 I (RECLAIMED WATER) OR 302-670 MARK TETKOSKIE 07/20/10 LIQUID WASTE DISPOSAL r-- A I RED I "SUMP ;;;;;\\ WOL-WOL-VS8 ~ ... _./7..-? DIAGRAM A l

I:(:CI~':'):J~~:::':JlJL-::,:':;--~'~;;,11,-~~~~PL~A~TF;O:"R"M~' \\:'~_~-WO;~L,,-;V;7~'~;l~~:V:7:'-6J,:::,::;;;;:::::;::::::::;;~::::::rll ___ ~:::::,'~'3:6:8~:!~~~~I'~~~;;;;~~::;:GP:';50:-:22RR:.1 __ -, ______________ !!~~!!-~NI!TR~O~GE~N!O!R!A!'R;!-!S!E!E!0!WG~30~2~-~6619~~!~,.!!-~!!~i!~~7hZ~O~/.. ~!~~~~~~~~~~~~~~~~

WDL P 78 WDL V242


t OR 302 720 u~~

~'" R.C. BLEED TANKS & MiSe WASTE COLLECTION ! ~.J I~ ~ Mise WASTE 1 1/2>> TO WDL T 2 N/R IDWG* NO I SHEET IR2"S' '-l~ cLT=,Cl! __ U-__ W_D_L_P_5_B ___...J~_ 2 TRA"FER PUMPS WOL VI83 1/2~~OL~V~9 3/8 ~S:EW:O~ 66:, ,~ ~g~ gg~ ~~~~Er~L;~CO~!~!~~~g~x I~ 7~~~O TMI*I I,,~ NfA 302-690 I L 4(G 5) AUX. BLDG. SUMP PUMPS 1 1/2" ~31)' AREA G 2 NO DWG NO REFERENCES TITLE INTERFACING CONCURRENCE 8 I 7 I 6 I 5 T 4 I 3 121 _,, __________________..J

7 8 I I

H I

I I IG I I I FROM DH-Y52 302-640 (H-5 FROM SF-V40 302-630 (C-2 SPENT FUEL COOLING SYSTEM ITI*HS DWG (F-7 FROM WOL-V47,48 TI-US DWG (C 8 3" ~21/2" 302-690 (E-2) FROM WDL-V70,71 3" THIS DWG (o-a* t.2"~ WOL-V386~ 2 1/2a I © ~85 "'L-V279 T-- E'T' Alif I EVENT 3" (3~~.';~(;=~ I 3" 1~~~~ FROM WDL-P-7A~ 1 1/2a 302-690 (8-3" 3" 1 1/2" 3" 6 3" WDL-V40 2 1/2" 3" 3" 12 1/2" 3" I 5 2" DRAIN HOR. PT-6 302-690 (D-8' WDL-V387 1/2" t~~ 302-669 2" PRECOAT FILTER WDL-F-16 3" 2 1 VENT HOR. PT-5 302 690 (C 7) 1 1/2" q').P r 3" '* '"". fG ~'WDL-V278 ~ I WDL-V284 1/4" ~* ,5 3" 302-692 {H-7 Fl-137 1 1/4" 2" DEBORAT!NG DEMlNERALIZER WDL-K-1A WDL-V204 2,, SAMPLE 3 2 1/2" 2" 1/2" er.. 11 112;. 2 WDL-V203 REVISIONS REV I ZONE 9 I VARESI REVISED TO INCORPORATE ECR-14-00032 REV. 2 WDL-V7 -1"-Q) AIR SUPPLY ~,~ .. gii 12* I 1* 11~ DEBORATING DEMINERALIZER WDL-K-16 WDL-V205 ~ ~N~ TAGGED VALVE SOLENOID HOOK-UP FOR VALVES MARKED "' V.-OL-V209 1 1/4" SEE 302-671 AREA G-4 2" SAMPLE TO WDL-VlO 302-692 (C-1 O)_ H G 1 1/4" ~gt r-... u.,..- I. .. i I. Y 2.. 2 n~ F 2 1/2" I .\\.V,, 2f _, ' 3" (SEE NOTE 10) I 11-lXJ'-"-li I 1 3" ~ ~--------~*----~...... ~! WOL-V69 F I I E D le I I I B A L __ 2 1/2" 3" 11/2"~ WDL-V432 VENT HDR. PT.5 302-690 (D-7 1HIS DWG ( C-8) SEE 302-671 AREA G-2 TO WDL-T-4 (}02-693 Qi=BLJ-1HIS DWG (F-8) TO WDL-V52 THIS DWG (G-8) TO WDL-V363 302-692 (F-10) FROM WDL-V434 THIS DWG (E-8 t/2" 1/2" 2" I 2" 1 1/2" S-11 S-11 2* 1 1/2" I I CATION DEMINERALIZER WDL-K-2A 2" WDL-V213 WDL-V215 WDL-V733 3" 3" 2" 1 1/2° NON-NU, N-3 RECLAIMED WATER a I 302 669 (E 3) ) 1 1/ 2

    • 4 1 1/2" WDL-V318 IFROM FLOOR DRAINS ~

ATMOS. 1 1/2" 3* 4" LAUNDRY ~~ir:: STORAGE I I 2" D 1 1 /2" I y WDL-V155 8 WDL-T-12 2* T WDL-V678 y WDL-P-15 LAUNDRY WASTE PUMP 7 WOL-V192 WDL-V350 WDL-V159 ~ T "2:V , 1/2" WDL-V156 2 1/2" WDL-V46 -1 h 1/2" 2 1/2" 3" WDL-V41 2 1/2" 1 1/2" 1 1/2" 2" 12 1/2" L___/FE\\ ~ 1 1/2" 1 1/2" 3" WDL-V157* 6 2" WDL-V67 1/2" WDL-V271 CATION 1 lli 2" I I DEMINERALIZER ~ WDL-K-26 2" 1 1/2" 2" WDL-V214 RECLAIMED WATER 302-669 {E-3) 1 1/2° -,_'u I o:::J V> zZ Ji WDL-V316 WDL-V190 I. 1/2" WOL-~ r.V V153 I. U y 1 1/2" ~ ~ 1 1/2" 1 1/2" 1 1/2" 1 1/2" Vv0L-V151 WDL-V366 TO MISC WASTE EVAP. 302-692 (H-10 5 WDL-V317 1 1/2" 1 1/2" ~ 2" TO WOL-T-4 t 3" 302-693 (H-8) ~ li!S' U V>Z => =>O z I= 0~ 8T;._::J ZV>~ WDL-P-96 1" 1/2" 2" 2" NEUTRALIZER PUMPS 4 I

  • I 11/4"

+ 11" 3" 1 1/2" 1 1/2" 1 1/2" LT ATMOS. 124 }ATMOS. NEUTRALIZER FEED TANK 2" NEUTRALIZED WASTE STORAGE TANK WDL-T-9 WDL-T-10 2" 2" 1 1/2" 1 1/2" 2" --t~ WDL-V147 WDL-V149

  • 2" 302-003 COMPONENT & SYS ID INDEX 302-002 SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM NO, DWG. NO.

TillE REFERENCES 3 y y 2 3* 1 1/2" Vv0L-V250 1 1/2" 1" NaOH 1/2" H2S04 NOTES: FROM MU-KlA,18 302-660 (F-10 FROM WDL-P-7A/B 302-690 ( A-3) FROM WDL-V158 THIS DWG (B-6 CAUSTIC MIX FROM CA-V158 302-670 (D-8) NEUTRALIZING ACID PUMP 302-162 {C-8 FROM WT-V152

1. VALVE POSITION SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR REUEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. ALL PIPING ON THIS DRAWING IS ~
5. ALL PIPING ON THIS DRAWING IS NUCLEAR CLASS N-3 UNLESS NOTED.
6. SEISMIC CLASS S-11 UNLESS NOTED.
7. ALL DRAINS AND LOCAL SAMPLES AFTER LAST VALVE SHALL BE S-111 NON-NUCLEAR.
8. A DENOTES THAT NO SCHEMATIC EXISTS THEREFORE THE PHYSICAL DRAWING IS FLAGGED.
9. FOR REFERENCES SEE DRAWING.302-690.
10. VALVE INTERNALS FOR WDL-V365 REMOVED.

E D c ~ 0 I Cad Fila Name : 30269LR9

===---1 Im THIS JS A COMPUTER GENERATED DRA'NING 00 NOT REVISE IT MANUALLY ExeJsJ!~ LIQUiD WASTE DISPOSAL FLOW DIAGRAM PRECOAT FILTER, CATION &: DEBORATING DEMINERAUZER. LAUNDRY, NEUlRAUZATION TMl-1 302-691 NONE 9 ~1 I A I I _ _____________________ _J

7 6 .,:;r,:-: I' ',a'Iif'l>'!: -ct.. "'*'f4*.1 4

    • i!l. 0

'H -f;J'.dJ.fTJ!q--* ~.;......,................................... -................. ~ "!*)*' l~'!t'**t.:4.: ':S[L<a;.?iC.: ~;.!(;*~;I~ ' ; E i le i. I ; B I 7

.~

,i.L&.'Fzlfit, r*'" 2 H G <LT!jfL!,_;.-£-'r;,,_~~~~*~~--"'- 1

  • ________________ ~-----------'"**:...---:'J;l~~~...,~~£;]~2~:~sf-Li;

~ ~ !ft."..'!i 1 .... ~~~~"*~~~~~~~~~~~t!l'~ - ~--~--:~~~-~c~~£-*~:~~,.._w~

  • !J:*

t !1'~ I I 'Y ..-.=::,~:r-I .. 1

  • ~.c:~~r~~'f.~~b 1* r.t~~tJ.:t~~~11*'
l. fS~~~~x&.T.P:~

o-**~W..

  • ........-..:<<>o,._!#.,~a !;>

I

  • 1 II c I L. __ ---*. -***-** --*-**--*-* *-* *-* *----*--*---**-*--*--** *-**--**-----*-** --
        • -.. --------*---*-*---------* --*-**-**----*----*--------*-----*-1

10 I 9 I 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 FROM WOL-P-9A/B,15 1 1/2" I 302 691 (A-5) HI F~~~-:;-r;~~At) 1 1 /2" FROM WDL V359 t 1/2" 302-693 (E 4 302-691 (F-8 FROM \\.IDL-V1172 G I 1uN~~22 2045 (D 2) D c ' B A 302-691 {F-8 WOL-V43 FROl-1 WDL-V73,74 302-691 (C-8 1 1/2" WDL-V363 RECLAIMED WATER 302 669 (E 1 N.S. N.S. A.S. A.S. 1" OUTSIDE EVAP. 1 1/2 WDL-V75 ~ 11/2" RECLAIMED WATER t /Z" ~ cr-U£--c I 302-sss co 1) )

s 4 CA-c JA A-V374A NON-S II S-11 BORIC ACID TRANSFER TO & FROM (C~~ITo1':-)

WDL-V622 AUX. STEAM 1" Ri;i~l~6E~ _(~ATIR ~ 1 /2" FROM V.OL-F-2 302-591 {F-1 FROM CA-V177 302-670 {D-2 WDL-V666 2 1/2" ~w

5~t
i::~J_

1 112* 2 1 2" 3~~-M6~~F~~ ~O) 3*~1~~30~2~6~9~0 ~(O~B)~) 2" WDL-VSO 1 1/2N S-11 IS-Ill FROM RECLAIMED WATER 1 t/Z" NON-NUC NON-NUC I Jo2-ss9 <o-3) ) I I

  • 11.. ~

1 112* 1... tkn REC1.AIMED WATER ~ THIS DWG (H-4' WDL-V554 ~------.--; HJsV&;NN MISC. WASTE FROM UNIT 2 302-690 (C-8 1 1/2" 1 1/2" 1 1/2" 1 1/2" r* 1 1/2" 6 TO SPENT RESIN TANK 1 112" ' 3o~i9; (~-a Pl6 TO USED PRECOAT TANK p 1 112* I 30~i9i(~-8 (~~~~ 1f6 ~~~E~~~ TE 10 u~~ 22045 {D-2 1 1/2" HITIMAN BLDG. J02-693 (H-5 FROM CC-V102 302-196 (B-6 1 1/2~ 302-693 {H-5 I _!..2'-[>_t-- AS-V223 1 1/2" 1 1/2" RECLAIMED WATER 302 669 (E 1 fFl'L_ er---- N.S. N.S. A.S. 1" 1 1/2" WDL-V665 I 2-*2' -1:>.t-- 1 1/2" 2" WDL-P-138 BORIC ACID RECYCLE PUMPS AS-V222 2" 2" 2" 111111 TO AUX. BLOG. SUMP 2"1 lo~o~~~~~Mfg_~A~ 2" WDL-V90 '14' 2" VtOL-V91 2* WDL-V92 1 1/2" WDL-V401 1 1/2" TO WDL-T-4 302-693 (G-8 1 1/2" ~ J_ ~ 302-693 (D-8) ) I TO WOL-T-5 I 1" RECLAIMED WATER -THIS DWG (H-B HOSE CONN. FOR WASTE OIL FROM 55 GAL DRUMS WASTE OIL FROM OTHER SOURCES ~ 1" 5 GAL WASTE OIL FILL CONN. 14 IVARIESIREVISED TO INCORPORATE ECR-14--00245 REV. 2 HOSE CONN. FOR lRAILER FILL 1" WDL-V670 WDL-V674 WDL-V657 J-.zi8tCE,.. ~14 114" I 1" WDL-V671 1/2" 1" WDL-V395 ~ PENTER oss NOTE B .t/2" WASTE OIL TRANSFER PUMP 1" 1/2" 1" WDL-V669 WASTE OIL STORAGE TANK WOL-T-17 WASTE OIL TRANSFER/RECIRC. SYSTEM AIR SUPPLY ~ T ~ 121~# XH. 1 SUPPLY XH. 2 1 2' SOLENOID HOOK-UP FOR VALVES MARKED t. TAGGED VALVE SOLENOID HOOK-UP FOR VALVES MARKED

  • FLAME ARRESTOR 3*

WASTE. OIL STORAGE TANK ~ WDL-T-27 4" 2" WDL-V718 2"

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS DETERMINED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND JN THE APPLICABLE ENGINEERING SET POINT DATA BASE.

4, tLrJ-J~IN8J~~I~ ~~fc:~~G IS ~.

5. ALL PIPING ON 11-llS DRAWING IS NUCLEAR CLASS N-3 UNLESS OTHERWISE NOTED.
6. SEISMIC CLASS AS NOTED.
7. ALL ORAINS AND LOCAL SAMPLES AFTER LAST VALVE SHALL BE S-111 NON-NUO..EAR.
8. ALLOY 20 PIPE PER ASTM B-464.
9. FOR REFERENCES SEE DWG 302-690.

~ ~ H G D c I I Cad File Name: 3021!92 B14 l Ex~!*ll!* .5UL-692 10 I 9 I 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 L-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------_J

10 a U-IF- ~;. . r } -*':41f . J L I * ~...:.."" - 1 .... l I I / I . ___ / J 1~. 4 9 4

8 7 6 5 4 3 2 ~ 1\\1 151 A c o E G FI H 10 2" ~ TO CA-T6 302 669 (H-7 TO WOL-V125 THIS OWG (G 7 TO WDL-V122 THIS OWG (G-7 TO WDL-Z-1B .302-692 (H-10 NON V'J TAGGED VALVE SOLENOID HOOK-UP FOR VALVES MARKED

  • 302-693

, '/2" ~,

J, y"g

~ l---.{: NUC N-3 S~ 2"::~""-1;*2" WDL-V248 THIS OWG (A-7 , '/2" (ji;)T 1 1/2~ 1 1/2" WDL-V379 WOL-T-11B WDL-V370 2" ~ . TO AUX. BLDG. VEN ~ EXHAUST DUCT, Vt'DL-V378 ," :B ~ 1 1/2" <¥J 2" I I RE'ASlONS WASTE EVAPORATOR CONDENSATE STORAGE TANK TMI*1 LIQUID WASTE DISPOSAL FLOW DIAGRAM SPENT RESIN COLLECTION & EVAPORATOR DISTILLATE WDL-V126 ~ AIRSUPPlY~ VENT 0 ~ 1 1/2" ~-V127 1 1/2" ~ ARP.20 SSTL NOTE B 1 1/2" "I. 101G-U IREVISED TO INCORPORATE EeR 07-00780 REV. 0 /0;,1"'7 INtERFACING CONCURRENCE THIS IS A COMPUTER ~~~E~~~ ~::~~~A~~A AmerGen REV I ZONE I DESCRIPTION '"o ICod File Nome' 302693 R10 I I~ '!) .L ---0 rSROO~A~~INCr:~~~4B (SEE 302-670) FR(),! RESIN FILL ~ ISO VALVE CA-V125B j)SEE 302.~67011O ~PT 353 EVAPORATOR CONDENSATE DEMINERAlIZER ~ 2~~B ~," WDL-V131~ 1 1/2~ .cP.' WDL-V117 NON-S~;,C 1~:I; 1 1/2" WDL-V229 ~ WDl-V128 ~L_V129 l'ill,*, 11/2" "/2" TillE 2" WDL-V252~ ~L 1/2H

  • V130 WDL-V115

~ ~ ~ ~--\\:!!Y WOL-V697 rl'r L, WDL-V609B COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM , '/2" , '/2" 1 1/4" ~, 11/2" ~L-V338 T ~.*1 ~ 1 2" WOL-V644 I VoIOL-V201 'w ~~ /2~L_ ~11!:! -'V645 4:J; LOCAL I 'u I YSAMPLE 6=> =: .co zZ th ~~ CHEM U?o ADD r.nz ~g~T ZZ on 1~ WOL-V360 WDL-V359f - 1/2"Y:::Fr-WDL-V609A 1/2" ~" WOL-V273 '0 2" 302-003 tI ~g;=gg~ NO: j- - OWe.- NO, ~L-V696 f ~ ~ -I t er RECLAIMED WATER PT PX FROM 'WOL-V610 317 317 I THIS OWG (A-7) )U{ 1"

(,

1 1/2" (f,1)(J,D 1," T_ ~L-V228 ~ RESIN SEE DWG CE FILTER 302-671 125 WDL-F-4 AREA G-4 WOL-V239 12" Y 'M)L-V114 .CD.' N-3 ~OUNC S~ WDL-V337 1 1/2~ WOL-P-14A 1 1/2" 1/2" ill WDl-V391 I EVAPORATOR CONDENSATE DEMINERAUZER LS ~ 272A ~" .:v-- - .~ I 2" ~L-V1$' WDL-P-14B S-I S-II EVAPORATOR CONDENSATE PUMPS WDL-V180 L-- WDL-V687 ~ 1 1/2" 3/4" ~ -33 ~L-Y V120 2" ~ If;'[)L-V251 CE12 ~ ARP.20 S.STI.-. 1 1/2" NOTE B 1 1/2" RECLAIMED WATER WDL-V116 I 302-669 (C 1) ) 1 1/2" -I FROM RESIN FLUSH ISO VALVE CA-V124A (SEE 302-670) FROM RESIN FILL ISO VALVE CA-V125A (SEE 302-670) DPT 352 WOL-V121 '.CD.. WDL-V642t t'1 1/2" 1 WDL-V200 'P' ~L-o r=r.n V643'- VI FE ,,:"lzg 1~11..- o."l"°z= "'~ ~~~ z th CHEM 2~ ADD-j '/2" I FROM DEMIN. t BACKWASH ISO. (~f~\\g~::6vigfA lli WOL-V118 WDL-VII9 <¥J I I I 1 1/2" 2" '~ TO WDL-Z-1B 302 692 (H 10 1 1/2" 20 PSIG NITROGEN FEED FROM CA-V127B (SEE 302-670) I I <fFROM OEMIN. ~ I I BACKWASH ISO. ~. I (tf~':,~t':-6Vj~)6B ~L-V230 I I ' '/2" I q> I, '/2" '/2" 20 PSIG NITROGEN FEED ~ WDL-V233 I, 9 FROM CA-V127A 1, 2" 1 1/2" , '/2" (SEE 302-670) Po .,, ' '/2 I .J / .. r ---..:!J --:::;r:j WDL-V274 - 1,- - - ~2.: ~ ~2-' - 1" l!2~ B,k2~~~SH Y "'If--'/'-2_"--I 1 1/2" WDL-V417 SAMPLE I "":*WDL-1 1/2"

  • 1 1/2"

~V416 LOCAL BACKWASH SAMPLE 2" TO SUMP HDR PT-3 302-690 (0-8 WOL-T-11A WOL-V698 , '/2" @T WASTE [VAPORA TOR CONDENSA TE STORAGE TANK ,1 1/2~ , '/2" 1 1/2" W'DL-V695~ ~ ~ .w. ~ E 288 HI,IL 2~ ~ 4" 3/4" WDL-V390 Y WDL-V235 \\llDL-V234 WDL-V369 ~T WDL-V257 1 1/2" TO EFFLUENT FROM MECH DRAFT CaQUNG TOWER 302-719 (E 2 WDL-V237 ,'f '/2" 0.0.~/2" 0.0. TO WDL-FI-1288 SEE CaNT. THIS DWG. (C-8) 1 1/2" Il} 1-' '/2" WOL-f1-145 1~ VENT HOB. PTA W I 302-690 (0-7) > 2" FROM Be [YAP. 1 1 1 1 2~ 1~ WOl-VS52 302-692 f-9 1 o WOL-V79 I ~~ ,I, WO~W6 ~ o WDL-V80 fROM MIse WASTE [YAP. 302-692 (F-7 it-~ 1 1/2" TO YlDL-V364 302-690 (F 6 LOCAL INDICATING METERS INSTALLED.

4. ALL PIPING ON THIS DRAWING IS UNLESS NOTED.
5. ALL PIPING ON THIS DRAWING IS NUCLEAR CLASS N-3 UNLESS NOTED.

1. VALVE POSITION SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES,

2. ALL INSTRUMENT TAG NUMBERS ARE PREfiXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR REUEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
6. SEISMIC CLASS AS NOTED.
7. ALL DRAINS AND LOCAL SAMPLES AFTER LAST VALVE SHALL BE S-11I NON-NUCLEAR.
8. ALLOY 20 PIPE PER ASTM B-464.
9. INTERNALS OF VALVE WDL-V357 HAVE BEEN REMOVED.

10. FOR REFERENCES SEE DWG 302-690.

11. LEVEL TRANSMITTERS LT-128 AND LT-129 ALSO HAVE:

WOL-V605 ~ WDL-V606 y 2" '/2" 1 1/2" tn LOCAL YSAMPLE NOTES: WOL-V247 RECLAIMED WATER t /2" ~ I 302 669 (C 1) ) NON-I ~ S-ll S-II TO FI-294 302 692 (G 7 TO WDL-V419 THIS DWG (G 8 ~ $SI WOL-V54 84 I I THIS owe (A-7) 1 CB; I FT I 84 1/2~ I 1 1/2~ V'JT ~ 'MJL-V199 .W.. 2" WDl-V198 1/2" lli IM)L-V186 WDL-V688 WDL-V236 2" 2" .eG" ~l WDL-V420 1/2" TO & FROM UNIT 2 --~ 7 uc ~~ ~:<< w, "Z 0< 6 ~ I ~~ ~ FrS-II S-I I g, 0 N-3 N 2 ~;o ~ W~ 0 (f) RB M,~!!,. ~I"il ~~ ~w o~ 8::g 5 4 3 SUPPLY FROM WOG-V163 ~I~ ~I~ -4 S-li GP 150 ZR SEE NOTE 4 (*) SEE NOTE 4 GP-150-2R GP-150-2R ~ GAS SAMPLE RETURN ,3/8" --S--II-AIR A 1302 671 (E 5) ; IP;~ i t ('I') SEE NOTE 4 SUPPLY FROM CA V47 2~ VENT v TAGGED----2 (*) SEE NOTE 4 VALVE 1 1/2" IV Vtl'll Ht.AUt..t( PT-2 302 690 (0 7) > SEEDWG~1/2 3/4" 3tt~)5~- Mise RAACT WASTE STORAGE TANK WOL-T-2 11'1 I ~' n <ill> .1 J WOG-Vl1 WOG-V65 2 45 IVARIESI REVISED TO INCORPORATE EeR-07-00ll3 REV. 3 WOG-V1Z 't.i 1 1/4-- r1 2" --l SEENOTE3~ 1 J VJ ~ 3" l/Z" 00 CA-V57 3/4" 00 WOG-V20 3/4" 2" J, ~ ~ NEOPRENE HOSE SAMPLE H G E o UU ILt.1 1;~~:6~~}E~,3LD ~-V23 1 1/2" 11/2" 6 5 4 WDG-V36 SEE NOTE 3 \\Il{)G-V25 NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED 8Y PROCEDURES 2

ALL INSTRUMENT TAG NUMBERS ARE PREFIXED 8Y SYSTEM DESIGNATOR UNLESS OTHERW1SE NOTED.

3. SET POINT VALUES FOR RElIEF VALVES TO BE FOUND IN mE APPLICABLE ENGINEERING SET POINT DATA BASE
4. ALl. PIPING ON THIS DRAWING IS NUCLEAR CLASS N3 UNLESS NOTED
5. ALL DRAINS AFTER LAST VALVE SHALL BE 5-111 NON NUCLEAR 6 SEISMIC CLASS AS NOTED
7. (*) STAINLESS STEEL TUBING, A213 TP304 TInE ------

3 2 c ~ rc;;;c,",--~ I'" ~e Nome <3026S4Y45 =:=J ~ I.......... mm.... I ~Ion. I~ NOT REVISE IT MANU ALL Y uclear WASTE GAS SYSTEM FLOW DIAGRAM A

H G I I

  • I
  • I I*

I* 0 f r c f .. I -**-- ~-~---- ~ I I t - ' I. t* .JO! I. ~ I... . f. l I I t t*

  • l I

I

  • ~

t -: *- .. r. r,. I l ... l .. r *-

  • .. J!...l__ _ _!..f__I tL-~JHl -*

J ~ J. -:. J I *- ~*... .. ~.. --r-- I - I

  • I I

I G

I I 8 7 6 5 4 60 PSIG AIR H I 58~t~ YM;~K~fiL 1/2" G F E D c B A 20 PSIG AIR SUPPLY TO ALL LINES MARKED 60 PSIG AIR SUPPLY TO ALL LINES MARKED e;,, 'I IA-V1678 1" WOL-V293A CONCENTRATOR FLUSH LINE 1/2" 100 PSIG AIR SUPPLY TO ALL LINES MARKED >--ftJ-,----w--cJ--7.I WDL -v-298A 100 PSIG AIR SUPPLY FROM IA-V1780A 302-279 SH 2 (C-4 3/8" 100 PSIG AIR SUPPLY


£ AIR SUPPLY DISTRIBUTION LIQUID RADWASTE DISPOSAL CHEMICAL MIX TANK FOR NUC SERV CLOSED CYCLE 6"

COOLING WATER 6" COOLING WATER OUT SEE DWG 302-610....._ - 1" ORIFICE ~ PLATE ~ 1/2" 11 IA-V1680 IA-V1676 RUPTURE DISC RELIEVES @ 13~1G

  • ~

TO FEED PUMP WOL-P-17 12.5 GPM WDL-V562A IA-V1679 ORIFICE IA-V1677 PLATE 1" 1" 1" 1" AIR/WATER SEPARATOR WDL-C-5A 1" 1 1/2" 1/2" 1/2" WDL-V558A I NSC~W _QN_l_ EXCHANGER NSCC! ~U] W_!)L_:9-~ __,) ( WASTE CONCENTRATOR (EVAPORATOR) WDL-T-16 1/2" WDL-V615 WDL-V580 al~ ~ B5 ~~ ~g ~~ 1"

\\

J WDL-V581A 1/2" WDL-V583A 1" 1/2" WDL-V584A WDL-V582A FOR AUX STEAM SEE DWG 302-051 STEAM IN 8" CONOENSA TE OUT 3" 1 1/2" IA-V1685 WLD-V649A \\ HEATING TUBE BUNDLE ~ '"I a I c-e 0 " 0 4'. 0 WASTE ~~~ci'~~~RATES ____...., - t'4 I @J 2 l*1 ' L ~ S( I FOR RC EVAPORATOR SEE DWG 302-692 ~ ~ Ii c-3/4" WDL-V-299A 3/4" FEED 'PUMP FLUSHING (RECLAIMED WATER) WDL-V267 1/2" FROM WDL-V1168A WDL-V680A ITHIS DWG (A--4) ) 1/2" ~ 1/2" TO ~ VENT 3/8" .8 MARINELLI BEAKER RCWE EVAPORATOR PURGE GAS SAMPLE PANELS 7 WDL-V413 y 6 WDL-T-14A 1" 2 1/2" 1" 11*M I WASTE FEED TANK 1000 GAL WDL-T-13A L FOR WASTE FEED TANK BUBBLER CONNECTIONS SEE DETAIL (F-2) FROM LT-21A I THIS DWG (B--4) >+- FLOAT VALVE 1" WDL-V266 WDL-V585A CONCENTRATOR DISTILLATE DISCHARGE THIS DWG (E-4) 2" WDL-T-15A WDL-V1186A SAMPLE PANEL THIS DWG (B-8) 1/2" 1" ~ DISTILLATE REJECT WDL-V586A 1/2" WDL-V587A TO IA-V1790A THIS DWG (E-4 CE )----[0i 1 1/4" f 1 1/2" TO WDL-V628A 20A DISTILLATE I THIS DWG (D 4) ) WDL-V732 A RESERVOIR DISCHARGE 5 4 3 WDL-V653A 1/2" WDL-V654A WDL-292A 1" 1" TO WDL-V293A THIS DWG(G-6) 1/4" WASTE FEED TANK (VENT CONN) 2 3-15 PSIG DESCRIPTION 1/4" 1/4" WASTE FEED TANK BUBBLER DETAIL - REACTOR COOLANT WASTE EVAPORATOR 4'. 0 1" WDL-V288A ~~ _\\ !ii IA-V1673 1" TO AUX BLDG SUMP WDL-T-13A DETAIL "A" FOR NUC SERV CLOSED CYCLE COOLING WATER SEE DWG 302-610 LOCAL y SAMPLE NOTES

1. VAL VE POSITIONS SHOWN FOR REFERENCE ONLY.

DISTILLATE OUT FOR RC EVAPORATOR SEE DWG 302-692 ACTUAL POSlllONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES ON RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. ENTIRE COMPONENT IS N-3, S-11, PER GA1 DWG 302-692.

H G F E D c ~I VJ 0 N Cad File Name; 302695 S1 R41 16-i tD c.n w 1-----~~~~~~~~~~~~~~~~--II THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear 1 ~~;;;; *:.,,.... "'."~;;*i LIQUID WASTE EVAPORATORS FLOW DIAGRAM REACTOR COOLANT WASTE EVAPORATOR 302-003 I COMPONENT & SYS ID INDEX I Nt/r 302-695 TM!-1 I ~ I 302-002 I SYMBOLS INSTRUMENTATION l""~NG MAI'<~- 0 OA'IE 302-001 SYMBOLS FLOW DIAGRAM r~ s//<lf/V 41 NO. DWG. NO 1 INTERFACING CONCURRENCE REFERENCES 3 2 A

I I 8 7 6 5 4 60 PSIG AIR H SUPPLY TO ALL LINES MARKED CONCENTRATOR FLUSH LINE G F E D c B A 20 PSIG AIR SUPPLY TO ALL LINES MARKED 60 PSIG AIR ISUPPLY TO ALL LINES MARKED I 60 PSIG AIR SUPPLY TO ALL LINES MARKED IA-V2916B 3/8" IA-V2918B 3/8" IA-V2922B f-------(B IA-V2917B -'20 PSIG AIR SUPPLY TO ALL LINES MARKED -~RIFICE ~LATE ~ 112,, WDL-V5628 WDL-V725 1" 1" WDL-V726 IA-V1702 IA-V1703 IA-V1701 1 1/2" WDL-V293B 1/2" 100 PSIG AIR SUPPLY TO ALL LINES MARKED ~WDL-V-2988 100 PSIG IA SUPPLY FROM IA-V17808 302-279 SH 2 {B-4) 3/8" 100 PSIG AIR SUPPLY AIR SUPPLY DISTRIBUTION FOR NUC SERV _ ___§" _ _ COOLING WATER IN CLOSED CYCLE COOLING WATER 6" COOLING WATER OUT SEE DWG 302-610....._ - - ---------1 8" IA-V1704 1" 1" 3/8" WDL-V646B CONCENTRATOR DISTILLATE DISCHARGE TO WDL-T-158 G I 2 ITHIS DWG. (B 6) > FROM LT-218 ~ IA-V1790B FOR AUX STEAM I ~E;ll~ -~ SEE DWG 302-051TUBE BUNDLE --- __ _:C;;.:O::,:N::;DE;;:;N:;:S;;.AT:;:E_;O;;,:U;,:.T_"-3'_'. ___ _ WDL-V663B WDL-V661B IA-V1696 DISTILLATE 1 1/2" IA-V1693 WAS~~~8ij~LENF~RATES..,._ _ t11 I ?LG c31<J '1 "- 2@4 r MISC EVAPORATOR I § SEE DWG 302-692 WDL-V261B 1" WDL-V299B 3/4" WDL-V680B i'::i~~ D~~(~12~)6) 1/2" ~ .. 1/J~NfO 3/8" 8 MARINELLI BEAKER MME EVAPORATOR PURGE GAS SAMPLE PANELS 7 1 1/2" CONCENTRATOR DISTILLATE DISCHARGE ITHIS DWG. (E-4 2" WDL-T-158 ~ © ~ l FOR WASTE FEED TANK BUBBLER CONNECTIONS SEE DETAIL (F-2) CE ~ I l/<1-I ~.. ~~

  • ~-~~

20B WDL-V7328 ITHIS DWG. (D 5) > 6 5 RESERVOIR DISCHARGE ~1/2".Jv, ~ 1" _DIAPHRAM SEAL W/4M FLGS. 4 3 1/2" 1" 1" 1 1/2" \\-<J -3l WDL-V653B 1" 1" H;~" -2108 AIRIWATER SEPARATOR L-WDL-C-58 ORR 1/2" ~v~~~B 1" 1" 1/2" 1" ~ DISTILLATE REJECT WDL-V587B TO LC-218 IS DWG. {E-5) 3 1/4" WASTE FEED TANK (VENT CONN) 1" SV. DISTILLATE DISCHARGE WDL-V288B WDL-V2908 1" 302-003 302-002 302-001 DWG. NO. IA-V1706 COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 2 2 9 I H-2 I ADMINISTRATIVE REV1SION TO DEPICT VALVE WDL-V1163B AS NORMALLY CLOSED - SEE IR 01627003-03. TO AUX BLDG SUMP FOR NUC SERV CLOSED CYCLE COOLING WATER SEE DWG 302-610 OUT 2 1/2": LOCAL y SAMPLE NOTES F~0M S~j~QJs 302-720 (8-5) WDL-V1178 TO WOL-V293B HIS DWG (G-6) =r=----__. FLANGED SIGHT GLASS 2" WDL-T-138 I MISC WASTE DETAIL "A" lE 26D/B. 1 1/2" DISTILLATE OUT FOR MISC EVAPORATOR SEE DWG 302-692

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGN A TOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES ON RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. ENTIRE COMPONENT IS N-3, S-11, PER GA1 DWG 302-692.

H G F E D c VJ 0 N Cad File Name: 302695 S2_R9 .~ THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear 1:;;;;;,mc,* ""'";;~*1 LIQUID WASTE EVAPORATORS TMl-1 FLOW DIAGRAM MISCELLANEOUS WASTE EVAPORATOR 302-695 2 SCALE: NONE 9 <D en N A

8 7 6 5 4 3 2 REV1SIONS REV I ZONE r ~RIPnoN 2 IVARIEsI REVISED TO (1) INCORPORATE ECR-03-00591 REV. 0 AND (2) TO INCORPORATE AN ADMINISTRATIVE REVISION HI IH ! GI IG WDG-P-1A WASTE GAS COMPRESSOR WDG-P-1B WASTE GAS COMPRESSOR \\--------------------------, 1--------------------------1 o c 3, SET POINT VALUES FOR RELIEF VALYES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE. F ENTIRE COMPONENT 15 N-3, 5-(1 ALL DRAINS AFTER LAST VALVE SHALL BE S-III NON-NUCLEAR. E

1. VAAfi;]AEO;b~~~5N~Hg~Ttg~LE~E~EyR~NR~ECJ>DNJ_~ES, (22 2,

ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. NOTES ~ ~~~L~~~~E~~TT "I11 1/4" FROM WOG-V21 302 694(C 2 TO WDG-V23 302 694(0 2) 1": I,, I 1": I -;---1 302 694('

3) >

I TEST WOG-V1051 !, 1/4" VENT -;(g1Sf-- - ANN UNCIATOR 1" ~A.S. t" i' 3/4" ~ VENT WOG-V100B LOW SEPARATOR A.S. LEVEL 1" 3/4" H20 V ".... v

  • 'UVU COMPRESSOR WDG-P-1B 3/4" H20 1"

MAINTAINS PRESET PRESSURE AT PUMP SUCTION WDG-V1042 SEPARATOR TANK WDG-T-3BI~~ 50 PSIG WDG-V968 ~2 2 50 PSIG VENT 3/4~ SEAL WATER HEAT EXCHANGER WDG-C-1B 11/2"P:' P:' 1 1/2" --- I NS-V87Br' T'NS-V88B I L--- 1__.- __ ~- - - - - _-----.J 1 I 1 I rio rC SEE DWG. 302-610 (AREA C-6) I,, I,, I I,, IAS~ DRAIN ~ 'I' I (AUX. BLDG. SUMP) WDG-V988 I

1

3/4" i DRAIN I~--I~~-=~

(AUX. BLDG. SUMP)

WOG-V99B TO WASTE GAS DECAY TANKS TO WDG-V22 302-694(£-3 100 PSIG N2 FROM Nl-V48 302 720(C 6) TO IliDG-V20 302 694(D 2) 1/4" ,-' ~I' RECLAIMED WATER rv ~ ~ 302-669([-2) I ,"! 1 1/4" I FROM Vv'DG-V18 302 694(0-2 ~AS ! ~!~ 3/4" ~ -ANNUNCIATOR ~ LOW SEPARATOR LEVEL WDG-Vl0DA 1" H20 3/4" 3/4" H20 MAINTAINS PRESET PRESSURE AT PUMP SUCTION TEST ! I WG-Vl049 I, I I 1~ I I~ac> !Ill wnr._Vlnn I WDG-Vl040 SEPARATOR TANK WOG-T~3AI~~ ~-~A COMPRESSOR WDG-P-1A 50 PSIG WOG-V96A ~2 2 WDG-V98A 50 PSIG IA.s~ I DRAIN VENT "I",

(AUX BLDG. SUMP).

JIll I DRAIN II .IJIII ~p I (AUX, BLDG. SUMP) SEAL WATER HEAT EXCHANGER WDG-C-1A 1 1 1/2"~.¥' 1 1/2" --- L N~-=Y~I__ ~S_-~8~ ~ ~ I I I I rC rC SEE DWG. 302-610 (AREA C-7) TO WDG-V19 302-694(D-3 TO WASTE GAS DECAY TANKS 302-720rC=-6) 100 PSIG NZ FROM NI-V49 F o E c B wo ICQd File Name:302595..R2 I~ THIS IS A COMPUTER ~~E~~,~~~ ~~~~~~.~?vl AmerGen N/~!Rr; 302-696 TMI*1 ./. 1M." ""U"'" UOI'OI~ I WASTE GAS COMPRESSORS FLOW DIAGRAM IA COMPONENT &: SYS 10 INDEX SYMBOLS INSTRUMENTAl10N 31 302-003 2 302-002 A N 10.1 30~~~~lNO. SYMBOLS FLOW DIAGRAM n11.E 8 7 6 5 4 3 2

8 7 6 5 4 3 2 REVISIONS REV I ZONE I DESCRIPTION 1 REVISED TO INCORPORATE ECD C306413 4" PW-V083 (ll1 PW-V084 6J 0::l Y y I 1 1/2" II FROM PW-V066 ITHIS DWG (A 4) Ii. I H PW-YQ93 G D ~I III c F E o N Ien <D OJ 1 NOTES 1. VALVE POSITIONS SHOWN FOR REfERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CONTROLLED BY GMSZ Cod File Nome 302-698_RI THIS IS A COMPUTER ~ __ GENERATED DRA'MNG 00 \\ GJIU' NOT REVISE IT MANUALLY .UCUAII / GAl

'7,",,"

o,,;'~a PROCESSED WATER ~. FLOW DIAGRAM A 2 4" REFERENCES ~ er:= I I I PW-Yl09 I J>-TOHEAT T TRAONG PW-V081 PW-V086 I - J SAMPLE SINK 6" CS 4" SPARE 13" SS 3 12" ~ARE PW-V006 PW-V008 PW-V060 3" THIS DWG, (G 4) 1 1/2" 4" 4" PW-T-2 12" VENT PROCESSED WATER STORAGE TANK (500.000 gal.) 3/4** (VI 4;1, ri PW-V044YPW-V063 1/2" PW-V133 LU DR MIN. FLOW BYPASS LINE I THIS DWG (H

6) >

4 1 l/Z"' PW-V054 3/4" 0" PI l1/L 0" FROM PW-V060 3" ITHIS OWG. (B-3) >-.., u (D) I L I @-~ I I 1 1/2" I" PW-V077 CHEM CLEANING BLDG. YARD. I PW PUMP HOUSE PW-V090 4" PW-V043 4" PW-V002 12" ~NT 12" SPARE PROCESSED WATER TRANSFER PUMPS PW-YQ07 3" PW-VQ04 pw-vOOJ ~ H tGiH\\ tGil\\ 2 2 W----W I I 12" ~RE L-- I I cD ----EB 12" SPARE 4" 3/4" 5 4" SPARE 4" (:'J PW-V048 3-1 4" SPARE 6" T~ ~ 7 L If I i PW= I I TO HEAT _ ~ TRACING r L 6 o ~10~O~2-~6~9~7~(B~-~5~)-~_..__._.2." UNIT 1 & 2 CONN. CORRIDOR YARD IPW PUMP HOUSE 2 1/2" 7 PW-V047 0/4" ~ PW-YDJ9 2 1/2" 2" 2" 2 1/2" WOL-V690 ~I 6" 4" I, '~, .J UNIT 1&2 CS S5 ~ CONN. CORRIDOR 4" "W 8 UNIT 1 & Z L PI 3: ~ T~oPW ICONN. CORRIDOR YARD IPW PUMP HOUSE I ~' it- ~ A PW-V131 I 6" I I 6" ( M ) n", "Mc "\\ ~ PW-V067 3/4" 4" oW_\\Inc=."7 4" PW-V132 PW-V088 8 IUNIT I & 2 CONN. UN~ 1 TURB. BLDG CORRIDOR .~ ~ WDL-V684 302-159 (8-5) E D A B G F c

H E D c B ELEV 337'-8" 1/2" 10 SUPPLY AIR 302-271 (-1 m ~/" ELEV 322'-0>> HM RB RB 1/2" MS 413 ELEV 314'-10" 420 421 422 ~" RR RR 407 PURGE INTERSPACE ~" RR RR 408 ~r ~" NS NS 404 40S NS NS 401 40' ~" RR RR 409 ~" NS 406 NS 403 A TMos..... f-MI-'---1 9 QUADRANT IV PP-V136 MANIFOLD "N n ..-JjZ" 00 OliTAGE,ROUTI~ELEV317'_6" FLA~4ES Lp-V222 333 415 [~ ELEV 314'-10" ELEV 311'-6" ELEV 309'-6" 417 PP-Vl09 301 8 7 6 5 4 QUADRANT III QUADRANT II 270' lBO* 241 1/2" l/Z" PP-V97 pp-- V96 SUPPLY AIR 1 " MANIFOLD "En 302-271 [-1 PP-V30 I/Z" SEE NOTE 4 PP-V29 PP-V28 PP-V27 1/2" I" PP-Vl026 1/2" ELEV RCP1B 338'-4" 236E 237E ELEV 322'-6" J 46 n J47 n J48 n J49 CO ~AIlE NS NS CF CF ELEV 322-6 345E ELE:u::: ~:TERSPACE 1/" 1!'" 1/2' 1/" ELEV 317-0. MU MU MU BS 336 337 338 339 34{1 ELEV 317'-0" 334 335 (LEV 317'-0" eRD eRD 1/2" 00 1/2" 00 [LEV ~ ~ E:212 ELEV 314'-6" : I~ '1 28

P_V227 2~29:p_V228 3/4" 3/4" 1/2" 303 l'

1" 1" 306 1'!2' eELEV274'-S" 352 TO MANIFOLD" J" Tl1ISDRAWING £-6 TO MANIFOLD "C' Tl1IS DRAWING C-3 PP-V86 ELEV 310'-0* MANIFOLD ~ J" 1" MANIFOLD "F" ~/2"~'!2 ~ ~ ~ 4 ~ElEV 299"-0 320 321 322 323 324 23 310 Y 3~7 3~~ BS ~/2" ELEV 273'-5" T'/2" r/2" G e ELEV 274'-8 3/4" 353 354 1" PP-V204 40 TEST BELLOWS /'" PP-V203 IN SPENT FUEL PIT (NOT TO EXCEED 20 PSIG) FROM FI-l03 THIS DRAWING B-8 FROM FI-99 Tl1ISDRAWlNG A-6 PP-V52 PP-V53 311E 312E TO MANIFOLD 'E" Tl1IS DRAWING G-3 TO MANIFOLD "D" THIS DRAWiNG D-2 TO MANIFOLD "G" THIS DRAWING C-5) 1" TO MANIFOLD "F" mSDRAWlNG 0-6) IMANIFOLD "G" PP-V55 202E 3/4" \\O£NT 3/4" VENT 3/4" VENT J/4" VENT 6 OU7r~~~~ING OU[tL~2~)nNG 221 222 1/2~ 1/2" 1/2" ELEV 324'-2" PP-Vl020F PP-V36 PP-V37 MANIFOLD "D" EQUALIZING VALVE FLANGES AND ELECTRICAL PENETRA TlONS INNER DOOR SEAL 207-REACTOR BUILDING PERSONNEL HArcH (ELEV 313'-1") FROM FHOO 11-IIS DRAWING A-6 PP-V56 203E OUTER DOOR SEAL PP-V180 NOTES 3/8" PI 436

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN mE APPLICABLE ENGINEERING SET POINT DATA BASE.

PP-V183

6. PENETRATIONS HAVE BEEN DRAWN TO ELEVATIONAL PROPORTIONS WHERE POSSIBLE.

5 4 MANIFOLD "C~ PP-VI82 1" 1/2" 3 pp-V26 pp-V25 219E ELEV 324'-2" PP-V34 1/2" 1" Tl1IS DRA'MNG B-8 3 90" FROM FI-98 THIS DRAWING (B-6) 1/2" FROM Tl1IS DRAWING 27 2 1 27 VARIES REVISED TO INCORPORATE ECR-07-00259 REV. 4 QUADRANT I (0(:) 1=. 1=, w u ELEV. 3.37'-8" 1/2" 1/2" ELEV. 312'-0" QUADRANT ARRANGEMENT ~,-""",,,,,,,-=~PENETRAl~2~ ~~~~~RIZATION QUADRANTS I THROUGH IV 302-706

SCAlE, NONE 2

1 D

'. G

c 11

.. 11 t

  • "¥"*

~~* r...:~~:*, w* r ~4..i" 1:1~!=**1" 8 7 e 4 3 c 7 s 4

IRrv I 70NF I REVI~~;~R1PTION 2 3 4 5 6 7 8 en, I I 22 IE,F-71 REVISED TO INCORPORATE ECR-05-00190 REV. 0 H H QUADRANT III QUADRANT" QUADRANT' QUADRANT IV 'G G D E c l[ 805W. 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTU.A,L POSITIONS CONTROLLED BY PROCEDURES

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY AH.

3 SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATABASE 4. ALL BRANCH CONNECTIONS OFF MAIN ARE 6" 5. ALL BRANCH CONNECTIONS REDUCE TO 2" BETWEEN VALVE AND MAIN 6 ALL BRANCHES HAVE FLEXIBLE CONNECTONS BETWEEN PENETRATIONS AND VALVES. 7. ALL TE'S REQUIRE 1/2" NPT MOUNTING HOLE AND TO BE CONNECTED TO TR 805 B. VALVES PC-V15 AND PC-V16 ARE NORMALLY CLOSED. OPERATE ONLY AS DESCRIBED IN OPERATING PROCEDURES NOTES 315 cn.1 315 CFM u ~/ /~ T" I I I I ~T T",o- ~T -W~l,,:. PC-V5AU ~ Lfi\\ W'" 103~ ~ ~85 CFM 258 CFM 12" 315 CFM '6" 315 CFM l[

05Y, TYPICAL PENETRATION CONNECTION PENETRAnON Ql;FlEXIBLE CONNECTION

,UNION IH 2 6 VALVE Yj REDUCER FD-59 ~ ,,~ T~ 1688 CFM 302-84HF-2 302-841(0-7 TO AUXILIARY BUILDING EXHAUST SYSTEM 2116 CFM 354 CfM 258 CFM COMPLETE SYSTEM IS Cl-I 120" 8" 8" 8" 6" 8" 8" I-PC-V12 ~ 6" _:_lf~'~ 328 TO AH-V3A (302 847 (0 8) u TO CH V19H 2 1/2" <302 847 (0 8) r--------------------------------~ FROM CH-V191 1302 847 (D

8) >

n___ FROM CH-V19F 2 1/2" ~o DRAIN I 302 847 (C 8) >---------------------------------~ TO AH-V3B I <302 847 (C 8) ~_------_-------------n----------2:-------n-----j c D

F
E B

'"o lead File Name 302708 R22 I~ co THIS IS A COMPUTER GENERATED DRAWING DO NOT REVlSE IT MANUALLY AmerGen A l.1ARKITTKOSKIE 5/07/07

  1. ,,/ ~,,6;;'

"'_~ i PENETRATION COOLING FLOW DIAGRAM A 302-003 .302-002 302-001 COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM """""iiii£ ':4 r/r6~ TMI*1 302"708 22 8 7 6 5 4 3 2


~

8 7 6 5 4 3 2 28 DESCRIPTION ~~~Sffi ~~~~N~~~:~~~E Rt~sfg3-C500069. H H G c o F E FILL FROM MAKE-UP PUMP 302-661([-8 FROM NI-V25 302-670(E-2 FROM CA-V252 N2 SUPPLY 650 PSIG 302-720(C-9 FROM MU-V75 ~-NUClEAR 1 5 111 CF~ ~=1~1 _1 M

11. 0.44 FT2 FLOW RESTRICTOR 8.

FOR DESIGN CONDITIONS AND INSTRUMENTATION SEE B & W DWG. 1043530. 9. SEE B & W DWG 135756E FOR PROCESS & INSTRUMENTATION SYMBOLS AND IDENTIFICATIONS. 4 ALL EQUIPMENT AND SUPPORT SYSTEMS ARE DESIGNED IN ACCORDANCE \\'11TH CLASS I SEISMIC UNLESS OTHERWISE NOTED 5. NO INSULATION IS REQUIRED OTHER THAN UP TO CF-V-5 A/B. 6. ALL EQUIPMENT AND PIPING 15 NUCLEAR CLASS AS NOTED. ~EE DRAWING 302279 SH. 8 FOR INSTRUME~ DETAILS TO VALVE OPERATOR. 3 SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATABASE. NOTES 1 VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWlSE NOTED '28'(') ~ lead File Name: 302711 R28 I~ N-2 Jf> CF-Vll CF-V16A CF-VlO 28'(') 28'(') R.B. RB~ ~ 2) 28 CD CF-V17 J I!(sEE NOTE 3)) ~[5-1:<& ---.IN-F N-2 Q 5-1 DRAIN HEADER 302 690 SHT l(H 3) wo ~ CF-V148 I CF-V158 t VT-V14B 13/4"* FOR CONT, SEE DWG. 302-713 ~ - -..t~~. ~~~ci2~~~3 CF-V328 CONTAINMENT ATMOSPHERE '4" 3/8" 00 CF-V48I 28,(2) 3/8" 28,(') FOR CONT. SEE DWG 302-713 l' 13 / 4" i 3/8" OD I 8(') tF2 u au LT3 048 ~IE R,B 1128'(') PENET 349 CF-VS8 1> 3/4" INSULATION TERMINATION CF-V35B 14" NOTE 11 f> 3/4" REACTOR VESSEL RC-T-1 ~ro !;~ o..~g o~ ro ~ ~g 1 NOTE 11) CF-V35A 3/4~ ~ ~ ~ "v ~, g g WASTE DISPOSAL er SYSTEM ~ 90 VENT HEADER 9' ," f 5-11 Q F N-3T N-2 $-11 N-2 N-3 PENET. 348 CF-V5A ED 28'(') 10" ~ ~Iro ~S U O W v o~, ~N 00 e'~ '28'(') CF~V4A '28,(1) CORE FLOODING TANK SHROUD FOR CONT. SEE DWG 302-713 l' [3/4" l i~~~T~J~?~N ¥'- <I!> I CF-V33A RTT 14" 14" C2T~~~~~[~J ri~;~ ~iV:",~21~"A;\\\\ ~2) ~----------- o ~ ~----------------R,B, -- t2~. %~N362~~~3 ~ -1 CF-V32A 28,(1) ~RB R.B. o c G B F E I I A 302-003 302-002 302-001 OWG. NO. COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM THIS IS A COMPUlER GENERATED DRA'MNG DO NOT REVISE IT MANUALLY AmerGen CORE FLOODING FLOW DIAGRAM 302*711 28 A 8 7 6 5 4 3 2

8 7 6 5 4 3 2 REV I ZONE ~I G c F H D E A 49 302*712 1MI-l REACTOR BUILDING SPRAY FLOW DIAGRAM AmerGen FROM DPT-819 302 640(F 1 57 TE NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROlLED BY PROCEDURES. 2, ALL INSTRUMENT TAG NUMBERS ARE PREfiXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

3. SET POINT VALUES fOR RELIEf VALVES TO BE fOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.

49 1[-3 IREVISED TO INCORPORATE ECR-07-00174 REV. 1 I,[/k/o

4. SYSTEM DESIGN BASIS SEISMIC CLASS 1.
5. NO INSULATION IN lHE AUXILARY BUILDING.

6. fOR DESIGN CONDITIONS AND INSTRUMENTATION SEE B &: W DWG. 26645F.

7. PENETRATION PROCESS PIPE IS SCHEDULE 80S.
8. BS3-LT IS ONLY A PRESSURE BOUNDARY. NOT A FUNCTIONAL COMPONENT.

9. THE DRAIN & FILL LINES ON EACH DANK CAN BE CONNECTED TO THE SUCTION & DISCHARGED OF A PORTABLE PUMP FOR PROVIDING RECIRCULATION PRIOR TO SAMPLING.

10. THE INTERNALS FROM VALVES BS-V~0023A

&: BS-V-00238 HAVE BEEN REMOVED. N/'" INTERFAONG CONCURRENCE THIS IS A COMPUTER GENERA TED DRAWING 00 NOT REIJISE IT MANUALLY W IC'Jd File N'Jme: 302712 R49 I~ 2 """,r-,..,.... ',,_ LOCAL ~.J(II..JI~SAMPLE BS-V12B <t1 3/4~... 120 PSIG N!TROGEN ~ II SUPPLY SEE DWG C-302-720 'V I'* FROM oH PUMP SUCTION HEADER 1/2~ 00 BS-V83 mi., REFERENCES COMPONENT &: SY$ 10 INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM BS-V19 BS-V18 OWG. NO. 302-003 302-002 302-001 1" DRAIN 3 3" P' .590 BS-V22A EO BS-V65 BS-V21A I I II DRAIN &: RINSE 3/4" ~

5

~z DH-V182B 4 BS-V87A BS-V61 SUCT. HDR. SUCT. HOR. ~z DH-V182A TO D.H. PUMP 302 640 (A 6 TO D.H. PUMP 302-640 (B-3 EO YARD VENT VENT - ----p;:UX1LARY-BUILDIN-G- - - ~1 3:56'" 7[5b'" SODIUM THIOSULFATE TANK ED as-V81 An.40S. ATMOY' VENT 3" V BS-V15 BS-V12A F 3.* 85-VIO1'0 P51G NITROGEN dL ~ 1'*3') ~ 1,1 SUP;~,Y_i~~ DWG BS-V4B BS-T-1 ~ \\F LOCAL SAMPLE" 1" b BS-V46 ED_*..YBS-V53B FROM IA-V144 INSTR. AIR 302-278(G-4 5 BEARING BRACKET DRAIN 3/8* 0.0 SET C 35 PSI 3/8" 00 DRAIN &: RINSE J 3/8" 0.0 1/4" 0.0. 1/4" 0.0. 3/8* 0.0. 3/8" .0.0. 3/B-0.0. 1/4" IA-v243 6 8S-Vl015 1/4" IA-V245 ~ ~ 9 5 FE' 8-BS-V10J6 N-3 B5-V60~- 3/,t~ N-2 0 10" SCH. 40 ~/4" 1~~~~ ~i':OlO BS-V24A 1/2"0.0. ISO. TEST 7 TEST as-V1117 8S-V1115 p, 8~ 1/4" IA-V238 0.0. I, I R.B f 18s~~~~EgE ~~~~R 302-640(F-2 ISO..J!.ST 6" 9 iif4EtI OOOq 00 DPT2 vv I ,I R<;_ V1AJ I

£8.

I :J N-' ,~ BS-V60BI_ FE' 6" N-3 'I': "~8T'/'" Fe as-V1111 3/B" 0.0. BS-Vl105 BS-Vl037 1/21 BS-Vll09 BS-V1103 1/2" ,,,_I ISO. TEST 2" HYDRO DRAIt\\ W1TH 1/4" HOLE 8 734 NOZZLES V~I@ 9 23 NOZZLES 2 1/2" 1.3 NOZZLES 4" P-J50 N-3 P-340 N-3 IL.UVt' 1": I'lULLLt.:::> ~---------I _ I I I Iii 1. Rk I 18S-¥1064 [, I, SS-V1034 P-J51 I N-J I 1/2"0.0. u.u. r - /.,"ron I I I I 55# N2 I ROTAMETER I p-,35,1 L ~ U.U , p.o. '0.0.,_,, __ 0,0. A B D c E G H IF

8 7 6 5 4 3 2 REVISIONS REV I ZONE H N-3 N-3 T T~O:OER~~~I~AU~A~T~~~NT ~ - _2- - - ~ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~ - 1 SEE OWG 302-690 WOL-V536 0-1 I REVISED TO INCORPORATE EeR'S 01-00467 & 01-00750 H G c D F E 3/t,." 00 1,11-\\1238 PX 1003 1,11-\\1296 1,11-1,1218 3/4" 00 C,5-1 150-Tn PIPE TO TUBE ADAPTER (TYP) 3/4" 00 CORE FLOODING TANK CF-T-1B V1-V248 V1-V258 14": 1" CF-V14B I


M-----.J I

I I I CF-V'8~ I I I I V1-V148 3/4" 00 T

  • CF-V3JB

? I 5 I AUXILIARY BLDG DH-V478 I fJ- -II- -M -.., ES *rDH-V4S I LD. FROM DECAY HEAT REMOVAL SYSTEM FO:=( CONTINUATION SEE DWG 302 640 0j~ I"' Z N J,lN I NO .k,g '1 2 I U ~ I I I I I I I iNDL-V525 I II- -"",-...!"-4 I I I ~ I J,t-I '"I I i tCF-V153 ~ I z I I I 3/4"1 I I I I I V'-V268 i I I "L I I I CF-V328.,~ I-'~'...... -- I I I I 14"1 I 3/4" CF-V4B .J j __'f_~ __ CF-V58 I I -----------J ~ ':-~~-- '0 1 +CF-V35611 ~t- ~ DH-v22B "-2,5-1 I: C'S:'3__~~1""";3::;/4"':OD-:~!:ri".1~.~i, ".~ " I f ~ I DH-V48B 3/.:'::'--0 r - -M-- - VT-V208 I I u I REACTOR BLDG REACTOR VESSEL RC-T-l INSIDE SECONDARY SHIELD WALL 'jN I .:g i: ~ 'IN ~*6 10 Z,~ 'I~ 0g VT-Vi4A 3/4" VT-V25A 3/4" 00 I I I I I I I I \\NOL-V524 1-1':'" -W- -"1 I I I

---1' I

CF-V'5A! ~ I N. I I z I I J T* CF-V3JA VT-V24A ?' I AUXILIARY 8LDG I I DH-V47A r - -M 4~--{;j DH-V4A ~ ES E.;~~ FROM DECAY HEAT REMOVAL SYSTEM FOR CONTINUATION SEE DWG 302-640 CF-V14A '14" I I 1" L----M---- I I I I ~CF-V'A I I I I CORE FLOODING TANK CF-T-1A VT-V20A 3/4" 00 VT-V21Af x 1000 VT-V28A 3/4" 00 VT-V29A PX 1001 VT-V23A 3/4" 00 I I I I I I VT-V26A CF-V32A 3/4..1 I ~I---"""'--i I I C,5-1 N-2,S-1 I 150-113 2500-2 I 114" I CF-V4A 14" j 3/4 I ICF-VSA 14" t __ ~ + ~., ~ I'D IICF-V35A* DH_V22A/1 I-L C,5-1 I N-2,S-1 -T-N 150-113 I i: I VT-V22A' 3/4" 00 VT-V27A I 3/4" DH-V48A I

  • H i

H [}-----M--., I I REACTOR BLDG I TO COLLECTION DRUM c D G E F B Cod rile Nome 302713 RS <511 gl i wi ~! NOTES 5 302-713 E "f'9(0'1 DECAY HEAT AND CORE FLOOD An"" FLOW DIAGRAM IA CHECK VALVE EST SYSTEM COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 3 302-003 2~ 1 302-001 No.1

DWG, NO 1

VALVE POSITONS SHO'NN FOR REFERENCE ONLY ACTUAl POSITIONS CONTROLLED BY PROCEDURES 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTIIERWISE NOTED I I A 8 7 6 5 4 3 2

8 7 8 I 5 I 4 I 3 2 I 1 I IREV.IZOt£ I R£V~~PTI~ I I ~=~¥I~I;:&~~J~E~~~~ONS~~~c:flT H H f-G G I ---l f-50-\\1106 ~ ..:J SO-"" 3/8" 3/S-I I 1

i\\

I F \\!51 F PI PI 12.9 "00 SD.:.r,,07 H T [- SO-VIOlS E.- ""NT SO-VIOJ ">FLE ~7 so-v", n ~7 SO-V92 f-so-vao 50-\\190 3/8- .~"TIT 3/8" "'i UN J/S" II." II." WDL-P-238 3/8" SO-1/96 1 '=/f'~ 50-'193 SO-V9' I 1 L r,," L Oc 1 2" 1112" L I 112" ~-{X}-, TO OTSG II sO:::82 302-011 (F-IS) > SO-F-I SO-V91 2" HOSE v SD-V9!5 MS-V8'A E 1/2" tEXIST.) E 3/8" SD-V8~ 7. SO-V98 50-1/78 2" ~ SEE NOTE" LJ DRAIN DRAIN I 1/2" '1 ISO-V97 -I t;?\\ II.* SD-V8' NOTES if- ~ 50-'.177 N2 """". SEE """ I. VALVE POSITIONS SHOWN FOR REFERENCE ONLY. I I 302-723 ACTUAL POSITIONS CONTROLLED BY PROCEDURES. I I (F-') 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 0 {,?\\ 3. THE PORTABLE RECIRe. SKID SHALL BE ISOLATED AND 0 REMOVED FROM SERVICE PRICR TO PLANT START-UP ~ ~I-INCLUDING CONNECTION POINTS TO EXSISTING PLANT. I" RECIl~C. FILL 4. THE INTERNALS OF VALVE SD-V98 ARE REMOVED TO n ""NT ALLOW THE NITROGEN MANIFOLD, ATTACHED THROUGH SD-V97 TO BE USED FOR MONITORING "A" OTSG SI'£LL SD~VM SIDE PRESSURE. ~ SO-V89 1110 3/8" SO-V76Y 3/6" I~L 3/6" CHEMICAL 5D-T-2 ADDITION SO-V87 SC~V86 TANK I I I LJ I L __ 5O-V79 50*\\163 C 3/8" 3/6" Y C PORTABLE RECIRC _ SKID ,- HOSEk: 1 tTOf>. (TELEOYNE) ~ SO-VI"'" X IEXIST.1GPU'll B (,I 1,_ CAD FILE, VIE,566.21.1000.001*.0201 0 FROH OTSG A [)RAINS I THIS IS A COMPUTER GEt£RATEO OWG. DO hOT REVISE IT MANUALLY I\\) I 302-196 (6-101 )- ________ oJ I-J 0> ~ HAITZKD 03/20/93 fiiiI!I NuclearI GAl I~~/P:?d DATE OTSG SECONDARY SIDE f-A ~d//_,~~TE FLOW DIAGRAM A IDESIGN LEADER DATE PORTABLE RECIRC SYSTEM 302-003 COtoPONENT L SYS lD nux ENGlt£ER DATE ~~iT II I. ~ 1"2' 302-002 SYlo4BO..S INSTAl..t4ENTATION MANAGER APPRD\\I"'- DATE 302-718 302-001 SYteOLS FLOW OIAGIlAlo4

SCALE, Nl>E OIotG.hO.

TITLE ENG.MECH. i"*' REFERENCES 8 I 7 I 6 1 5 T 4 I 3 I 2 I 1

H IG !F I ID B IA ~ ~ 1_:t> l

c,"

I 2, I~ 8 I ii ~ Fl "'"I 00 I I uo ~~ ~~ EL 281'-0" 8 ~ 11760 CALLON I HEAD STORAGE ST fl.NU 7' 2" 4" 4" f-LOOR JRA,l\\JS ~ 2" 4' FLOOR DRAINS ~-" 14" 14, i(l~T) LT, 8.06 so7 c" 11° I I 4" I "°1 0 ~ 7 ~ I "-1 c ~ 6 1 1 /2" 1 1 S-111 S-1 S-111 SD-\\125 5 REAC I OR BUILDl"IG TO MS 302-011 R.3 -o IAS-V981:J I 302-011 (F-7) &-f \\~~6 [1 ;~o (/ _J____J' V27 ~. 3" 1/1" I <fl 4 T T wn1 -v:i10 / I>, /wrn-V.51? 3" - I SD-Vl 5 ~n-W< ~ 2" SD~l TUCBINE R00'1 SUMP l\\-l...__....... _,..... ___ t--W;.-J.. l~P-23

~D~~~:

1:D1,,V17 I 3. FOR CONTINUATION S0-\\/75 STEAM GEN. t 11" L SEE DWG 302-196(8-:1') D~Ai~:u,i;;., T ~ T ~~:;- 1so. rcsr BORA TEI TUNN~A 1~RM~ ANK ~------_@ ~I 7 VE"IT SAMPLE 1/2" R.B. WDL-V534~ DRAIN EL 262'-7" 6 WT-T-27 It n z w WDL V 25 WDL-\\/613 WDL-\\1532 t+- 1 I 7; ~ EL 281'-0" WDL-V504 GRAVITY DRAIN WDi...-\\1527 v FROM FROM lvlU-F-.3 302-660 (D-4) F~CM TRUCK BAY DRAINS 302-2045 (C-7) Jr E TO Ul~IT 2 AUX. ELDG. SUMP 1/2" WDL-V505 WDL-VSOJ / / Wnl_-\\/502 Wnl_-P-16(S-3) 5 4" N d, i"i'~' ~ti~ <( O} O} (jCt:: w I ~~ ~ t 2" 4 2" 3 B~A AIR SL.'PPL Y ~ I I ~ ~~ VEI\\ T TAGGED

14)

VAi VE SCLENOID HOOK-UP FOR VAL YES rJ ARK ED * (7 P'_ACES) T WDl -V.'10R/ 2" 1~ 161 WDL-1/1063 T I l\\ /wnr - v~,oq I F.C DL FROM EVAP. INSIDl,OUTS'DE BLOG. TO RADIATION 11 1 /2"' I .-1 I 13" I ld_ON.LIQR PIL. => ---i---tJ""" 302-202 '.B-5) S-?IS-1 4~> 2" THIS DWG. (A-3) flOM AUX. BLDG. ~** DR./\\,INS AT ELEV. 331'-0"' & DRAIN OUTSIDE REACTOR BLDG PERSONNEL HATCH AT. EL. 305 WOL-V531 .... (':)(: 4" BLDGrnG~tL~~¢cz~rl'JS SUMP 4" FROl'1 WDL-1/500 THIS DWG. (D-2) 3 (~\\ 0!'\\~ \\i§J(~!Y~ SUB-B/\\SEMENT FLR EQUIP DRAINS 302-003 2


:I 63 I E-4 \\ADMINISTRATIVE REVIS ON PER IR 1560.500-02, WHICH REMOVES REJ-c:RENCE TO "ss Lll\\E~" AS R:::LAED TU B\\llS-

-ur~NEL SUMP NUIT'.3 \\/ALVt: PUSITIUNS SHOWN FOR REFERENCE CNLY ACTUAL :::ioSITIONS CON I f-WLLED BY PROCl:.DURES. 2 ALL INSBUMEI\\. T TAG NU MOERS AR[ PREFIXED BY SYSTElvl DCSIGNATOR U\\JLESS OTHERWISE NOTED. .3 ALL SUMP -11GH LEVELS SHl\\LL BE ANNJl\\JCIA"iED IN -;-hE COl\\JTROL ROOM 4 ALL STAINLESS PP[ SCI ICDULE 105 UNLESS OTHERWISE NOTED ti. ALL FLOOR LJRAINS - 4 11\\'CH. 6 ALL EQUIPMENT lJRAINS - 2 11\\JCH, ANC EXTEND 6" AdCl/C. FLOOR 7 ALL LOCAL FLOOR D"<:AINS, ZU"<:N VfODEL Z-730-\\/-75, OIL 8 l'RO\\/IDE CLEAN OUTS W-1ERE CONVEN ENT

9.

ALL VALVE LEMOFFS TERMINATE AT CLOSEST DRP.IN AL_ ENTRANCE~ OF DESCEND NG STAl"<:CASES TO 3E PROVIDED WITH A SUMP 11 "2 ALL EMBEDDED PIPING SHOWN IS SE'SMIC CLASS 111, UNLESS l\\JOTED SYSTCM DCSIGN P~ESS./TEMP.-75 PSIG/150T

14. INTERNALS OF THIS VAi VE HAVE BEEN R:C:MOVED H

G I !1 I I I IF E D c 91 I [~ 0 N Cad File Nome: 302719_R63 I Tril5 IS A COMPU-ER GENERATED DRAWING CO NOT REVISE IT MANLALLY Exelon. Nuclear °'/C6/H I SUMP PUMP & DRAINAGE SYSTEM ~ 1_,,~:;_(RE.~CTOR &.~UXILIARY BUILDING) I ER DA1E Fl_OW DIAGRAtvl TMl-1 302-719 63 NONE 2 CD m II I A

I

H I

iD I ic ! *B m ~ M f;i i~ ~.. t) f D i ' c ~*

F 10 1/2"0.D. 9 8 7 6 N2-20 PSIG 3/4" RECLAl~EO WA TO CA-V234 5 4 3 ~ 2 I 1 1/4" d.D. 42 I G-4 l~~\\.15ff.J~J~95~%R~~TEA~oA~~~LT~~~DRJii'1~W~1P~g;T BOUNDARY. 302-161 (G-1 G E D c B I I I I I I STOOAGE TAW

  • -~:'. ~Nlf.,._

eYtl-3-8 t!!-_!il{fG~~-~Ol. ____ - NITROGEN ,._B~~a(6~fe I ~ IJ

i:::

I <I <I <I <I <I - I <I <I <I <I < l ... I m I m I m I m I m I "'I ~I ~I ~I ~I I I I I I Nl-V2 AlMOS.

  • 1/4" VENT H~R~~~N-3/4" I 302-661 {C-8) )M~~~KUP j

N2-100 PSIG 1" 1" 100 PSIG 1.~-v1~2" .v "I!>> LI. OUTSIOE INSIDE R.8. -------;:::-J FUEL IBAN5FER CANAL P" Nl-V30, ~ AREA-ELEV. 345' -o* [ 1 rR~B. 1" Nl-V3 )E-t-aim ITT' ,;e 8:~ g~

r J,

PENETRATION PRESSURIZATION SYSTEM .<l. I>. .V*~- 1" ~F J, ITT1~* ~~e ~ig g~ N2 MAKEUP TO WASTE GAS SYSTEM <10-ITT' -o >-6 ~ g~ mlm ITT' ~~ ~~ DEBORATING 3/4" NI-VB iL2" N' No <1*m =;::; ()~ g~ CATION ~ ~ Nl-V9 1/'."" ~~ ~~r <~ ~~ mlm ~' N< ..1: g om g~ EVAPORATOR CONDENSATE ~-------------- DEMINERAIJZERS FLEL 305'-o" Nl-V10 11_2~ <ITT nc', ~~ o~ ~~ Nl-V42 ml*~

Jc',

>-6 ~ g~ MAKE-UP & PURIFICATION Nl-V12 STEAM GEN. 8 <flt> ~H Ni-v29 1* TI Nl-v27 ~=*:-=============~=====---~----~==================== 3/4" ~!j[jp. ~ 1" <CW> 1:: ~~ Nl*~*2 1* 1" ,Nl-V14 1/2" 3/4" 3/4" [ffi

  • 'o/-~r~,~~ _ ;r _,:~ J lj _i _,

3/4" TO RC-V16A BLIND FLGS. ~ ~ TO RC-V19 N1~~~3 1.. Nl-V34 R~B. ~~ Nl-V22 ISO TEST ISO TEST ~!:!-1 CC-V13 01-r~ 01' g~ CORE FLOODING TANKS [ ~{,8" 3/8" Nl-V49 Nl-V48 I I 00 CD !z: I I (3~ ~~ "'~ ~in~ ! g ~~ ~~ J.J, ~J.6 ~~-4, ..!i~ ..!i~ ~~ ri'.8~ ~s 10 Ii! 01 ~ O> 1Df2

!CO Q ID f2~

~~ ~ 8~r ~ R.C. WASTE MISC. WASTE WASTE GAS MAKEUP EVAPORATCfi EVAPORATCfl COMPRESSORS TANK 1/2" Fl 1125 ~I, ~~ g~ Al gt-Nl-VlU\\I 1,, Nl-Vl.lU 1" 30_2_-_19~- F-5 w-1" z 1" 1" Nl-V1U/ SEE NOTE 3 1" 1" 1/2" 20 PSIG J( Nl-V19 ll r-1 I 1/2" Iii< [ 6 ~1~~1*N* ~~~~ uf2 ~ g NI-VI 05 WASTE GAS DELAY TANK FLGD. CONN. FOR SODIUM HYDROXIDE &: 1/2" ~ I l~I 0 g ~ R.C. BLEED TANKS I 3/4° 'J!' 2" 1" 112* 0.0. Nl-V142 1~-;-r:-..1 1/2" O.D. TO MAKE-UP TANK VENT 302-694 (H-5 SS TUBING A 213 T.P304 NITROGEN SUPPLY FROM H.P


CYLINDERS TEMPORARILY I

  • NIMS J ~~&3~~~M~

DISCONNECTED

  • <l. e:..

.v *!'a UNDERGROUND DESIGN CONDITONS DESIGN DESIGN SEISMIC CLEANLINESS GAi PIPING FLAG PRESSURE TEMP. CLASS SPEC. ~ 2400 PSIG 100'F Ill B ~ 150 100 Ill B (150-2) 150 100 III c (150-1) 650 100 III c (600-1) .&. 150 100 I EXCEPT c (150-t) AS NOTED &\\. 650 100 I B (600-2) fl:, 650 100 III B (600-2) 150 100 Ill B (C-1)(CU) 2400 100 ,!Ji. 150 100 I c (600-1) 831.1-1955 SECllON 2 "INDUSmlAL GAS AND AIR PIPING SYSTEM"

  • PER GAi QUALITY ACCEPTANCE SID. SP-5550 FOR FIELD USE ONLY NOTES:
1. VALVE POSlllONS SHOWN FOR REFERENCE OOLY.

ACTUAL POSlllONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED *
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. PS653A AND PS653B ARE ABANDONED IN PLACE.

G E I ID I c 0 N jcadFllsName: i'JOZVOR47 I~ 0 G:J~R~TE~ co~~~R oo I i:v*lo.. NOT REVISE IT MANUALLY ~ b l A 00,_," ~L-ms~ NUCLEARPLANTN2ANDH2 SUPPL y PIPING I A ~ ~Al~~P~;L_ 1/4" 0.0. 1/2" FLOW DIAGRAM (NORTH SIOE)T.BLOG. TANK LE~ 3 302-003 COMPONENT & SYS 10 INDEX ""' "°* 302 72 SH. REV. BUBBLER~~ 2 302-002 SYMBOLS INSTRUMENTAllON TMl*1 Q 42 T'rPICAL 1 302-001 SYMBOLS FLOW DIAGRAM SCALE: NONE NO. OWG. NO. TITLE A NO. 10 9 8 7 6 5 4 3 2 1 SODIUM lHIOSULFATE TANKS. SEE DWG. C-302-712 WASTE EVAP. COND. STR. TKS. 302*

-*-===--- I 8 7 _I - ---==-=---==----=-:....----= --==-------=-=----=-- =-----==------_ ---= 6 5 4 3 END PIPE NEAR REACTOR BUILDING I RM A2 CABINET "]__ - RMA2 SAMPLE PANEL 'H r4 REMOVABLE SPOOL PIECE COOLING~AN DISCHARGES fiD : ~ ~FS I F~ "'\\~~~1 ES 1" C0:~~2noN 1 P-108 CM-V41 CM-Y3 1.-~ (§;--., l 1 __ C _____________________ l G F 'E I I iD I lc I I 1/2" CM-V46 I SEE NOTE 5 ~ 3 8" 00 FLEX HOSE TO BE CONNECTE~ / ~ ~~~~~gr~x~~~f JBR~~ sYsTEM I

  • 0 PERIODIC LOCAL LEAK RATE TESTING FOR CM-Vl/2/3/4.

1 I I I I I ISO. TEST v; v; 0 0 S-CM-V42 1/4" OD CM-V44 ~ 1"c~ IPI --~ --i ',T~M-V5 CM-V~ / I 1."""* '" tg?g@;\\?g@g%3g@g@g@g{b~8~\\@g ~ =:=::~@-::-g~~~:=:=::~@~ ~-- --tRMA2-v8


---- ------- --:!J 1"

2 1/2" 1/4" OD SS ~~ CM-V21 CM-V17 3/8" OD CM-V22 1/2" OD SS ALL LJNES AND ELEMENTS TO SLOPE IN DIRECTION OF FLOW DOWN TO THIS POINT INSTR. AIR 302-268(0-4) ~ TEST CONN.~ HP-V5 H2 ck HP-V4 ~*~ (ili)>' ~*~ I 5-50 SCFM a 0 0 ~I 1/2" 00 ~- 1/4" OD ss SEPllJM ~~.,-~ I 1/4" oo 10


~

PS1A "-~ 5 CM-V29 1 """ 'fL vv. I Tl ~991 1/4" OD ss 1 'T' CONTAINMENTS:~~~~H;~!Tro%ST-ACCIOENT L _____________________________ _j SEE NOTE 3 CM-V27 CM-V16 1/2" 00 3/8" 00 s.s. RMA2-V7 2 OPERATING DATA (CONT. AT. P.A.S.S. ONLY: RM-A2 NOT INCLUDED) U> SCFM PSI A °F(MAX) BY REMARKS REV 1 0.95 69.7 250 DHS RECIRCULATION WITH 2 8.45 70.0 <165 DHS BUILDING @ 3 7.50 114.7 DHS 55 PSIG (OR LESS) 4 0 14.7 250 DHS AND 160'F(OR LESS) 5 0 69.7 DHS 7 0.95 69.7 160 DHS 8 8.45 70.0 165 DHS 1 0.2 44.7 250 DHS SAMPLING WITH 2 7.70 45.0 <165 DHS BUILDING @ 3 7.50 114.7 DHS 30 PSIG (OR LESS) 4 0.2 17.7 250 DHS AND 160'F(OR LESS) 5 0 44.7 DHS 7 0.2 44.7 160 OHS 8 7.70 45.0 165 DHS 1 0.75 44.7 250 DHS PURGING WITH 2 8.25 45.0 <165 DHS BUILDING @ 3 7.50 114.7 DHS 30 PSIG (OR LESS) 4 0.75 17.7 250 DHS AND 160'F(OR LESS) 5 0.75 45 DHS 7 0 44.7 160 DHS 8 8.25 45.0 165 DHS 1 21 69.7 250 DHS MAXIMUM LEAK 6 7.5 94.7 120 EJA WHEN REQUIRED DESIGN DATA fll NORMAL UPSET REMARKS PSIG 'f' PSIG ' 1 0 120 65 300 2 0 120 5 120 3 65 300 150 300 4 3 250 150 250 5 150 120 165 120 6 2200 120 2420 120 7 30 200 30 200 8 30 120 55 165 ~FROM LOCAL CONTROL PANEL NOTES:

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTilERVJlSE NOTED.

11 11 11 11 11 11 REV 11

3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN TilE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. VALVES CM-V7 & CM-V8 ARE TO BE SEISMICALLY SUPPORTED PER SPECIFICATION SP-5578, BUT NEED NOT BE SEISMICALLY QUALIFIED.
5. VALVES CM-V7 & CM-V8 SHOWN WITH VALVE OPERATOR SOLENOIDS DE -ENERGIZED.
6. (NOTE DELETED)
7. DESIGN CONDITIONS FOR PIPING SYSTEM BETWEEN REACTOR BUILDING & CM-V7&CM-V8 ARE 65 PSIG AT 300'F.
8. DESIGN CONDITIONS FOR PIPING BETWEEN CM-V7 & CM-VB

& RM-A2 ARE 5 PSIG AT 120'F.

9. VALVE IS NOT TO BE OPENED UNTIL UPSTREAM PRESSURE IS BELOW 30 PSIG.
10. PIPING SYSTEM IS SEISMIC CLASS I.
11. VENT DUCT TO REACTOR BUILDING PURGE EXHAUST SYSTEM IS SEISMIC CLASS II.
12. DESIGN CONDITIONS, REACTOR BUILDING TO HP-V6 ARE 65 PSIG AT 300'F.
13. DESIGN CONDITIONS, HP-V6 TO REACTOR BUILDING PURGE EXHAUST SYSTEM ARE 5 PSIG AT 120'F.

H G F E D c ~I I I I I I I I I I I I HP-V3a:: I ~*~ ~------1 CM-T-2 ~ HP-V7 I rD '<t B 20-200 SCFM 26 3/4" A ISO. TEST DISCHARGE SYSTEM 8 7 6 5 4 3 302-003 302-002 302-001 COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 2 ~I' I Cad File Name : 302721 _R26 ~- THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. ~ HYDROGEN PURGE FLOW DIAGRAM A 26

I I H G F E D c B A 8 3/4" l~-r-- HR-V24 DETAIL A LOCAL LEAK RATE TEST FLG (SEE NOTE 4) I I DETAIL.. A" ~ R~~~~ANB~fE s:)OOL R.B. ~" '2" VENT I HR-V22A I EXHAUST I RISER 3" SI 2" HR-V22B 3" 7 6 HR-V06 HR-VOS co.J:i~~TION I INSIDE OUTSIDE REACTOR BlDG I REACTOR BLDG I 2" SI 2" ~SEE DWG 3'.2-831 PENET. 1 6" f 6" 1~111i3 ~ I 1/?" L~-~2 6" Jto------i TO REACTOR BUILDING ATMOSPHERE SEE NOTE 3 2* HR-V23A 3" HR-V238 I REMOVAJ I SPOOL PIECE I I ~ ENET I 5"

  • A::ftli' 111'13

~ ~ 111---u--1 b- ~ REMOVABLE SPOOL PIECE 8 7 6 5 BLIND FLG. ~--lTMOS 5 4 TEST ~ONNECTION HR-V15 RECOMBINER PACKAGE HR-R-1A 3 2 14" DIA EXHAUST DUCT I I TO ATMOSPHERE


+--!-- OUTSIDE AIR COOLING AIR INLET 14" DIA EXHAUST ouCr 3000 SCFM

  • ]>

TEST CONNECTION ..... _ _,_,_ TO ATMOSPHERE HR-V17 ct:: -,. J 11 BACKUP RECOMBINER PACKAGE HR-R-18 C,S-111 SPOOL rt PIECE I 54 SPOOL PIECE 1111-----r--i SPECTACLE PLATE SEE NOTES 5 & 6 LR-V55 (TYPICAL 2 PLACES) DETAIL B LR SPOOL PIECES VENT OUTSIDE WALL INTERMEDIATE BLDG.


+--!--- OUTSIDE AIR 3000 SCFM COMPONENT & SYS 10 INDEX

302-002 SYMBOLS INSlRUMENTATION SYMBOLS FLOW DIAGRAM DWG. NO.

TillE REFERENCES REVISIONS REV I ZONE DESCRIPTION 5 I VARIES I REVISED TO INCORPORATE ECR-14-00033 REV. 1. NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGN A TOR UNLESS OTHERWISE NOTED.
3. THESE CONNECTIONS ARE USED FOR ISOLATION VALVE LEAK RATE TESTING OF VALVES HR-V23A AND HR-V238.
4. DETAIL "A" LOCAL LEAK RATE TEST FLANGE IS USED ONLY DURING ISOLATION LEAK RATE TESTING OF VALVES HR-V22A AND HR-V22B DURING NORMAL OPERATION THE REMOVABLE SPOOL IS INSTALLED.
5. BLIND SIDE OF SPECTACLE PLATE IS FOR CONTAINMENT ISOLATION ONLY.
6. FOR CONTAINMENT VENTING AFTER INTEGRATED LEAK RATE TEST,
1) INSTALL SPOOL PIECES {SEE DET'L B), 2) SWING BLIND SIDE OF SPECTACLE PLATE AWAY, AND 3) SWING SPACER SIDE OF SPECTACLE PLATE IN PLACE.

H G F E D c !I 9 (,.J 0 N I Cod Fiie Nome : 302722 RS I~ THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear HYDROGEN RECOMBINER FLOW DIAGRAM TMl-1 302-722 A NO. N ~ A 5 4 3 2

H G F E 0 le -~~~; l!... - B A 8 L T 1 !Ff*"" _,, l'L '..,,~ A,l'~L 'w ':.l ' .~** * < :

  • * * ~ ** '~ ~ *

~ ] ~::~- :: --~; ; ~ ... 7-'S ,..;."'~... --M ~

  • ~
f. :'.--

~:

.~......

-~~jl'f *'

  • 1**:..."::, ""'

~';"'..,;j::.**t:r.~T ,..":' 11~ f--if*-" Ea. 6 A",\\:- 1 ~~-- l !;!::~~-.~-

  • "" ".,.i'W.,.'ii.. i::r.u*: *'f,'l:t 4

3 2 tw.rr;<;.

£~,.~~~;~V;'~~'J~~;
'.
k~~'t,L_;~-:,'t'..~~*?!:~'"L~t**

} ~I.~ ~~;;'r\\~ v ~~'9.°'f~:~,U ~ ....... d. ' ~l~~t~::tj~;;~1[~i~~it~ ~1tU?r

  • ,I\\.~*~~<,:, 'M~'"-'~11':.l'f r:r~ ;-.:1'l~!~t
  • ~o.,t.;;~tA:...

~ ;{~~g:t~~l! ~)':lj.;~*~.n~.~~':1~~t*1:~ ~\\,. ~n~ta *\\4't ~*u_ lltC 11 t.trr..<..11 1.1'1t*:tll ~:::::1::;:,; \\i"{n;..:i.t

    • .~Jl... t,Jo,I')

G E D c ' A

8 7 6 5 4 3 2 REVISIONS REV. lct£ C£SCRIPTICH 2 N/A MlMINISmATlVE o.wa TO lloPlEI£NT AODITIQ-IS. EtfoIA/ICE~NTS AI'Ll CORRECTIONS l).£ TO REO£Cl<ING CF OIlGS FROM "'-'N.JAI... TO CAD FtRMAT HI IH REHOVABLE SPOOL I" ~ I~/I. II t" -------...... 1__302*~20...!C~J__>- - -....,......-- -. - ii" - - --,_ ~~~-~_/ NI-VJ2 RC-VI6A F G - - {~Sr..!!~ t,~- - -- J-=-_30~2.I~D§l-=--,,' SO-V')7 50-'198 AL TERNATE HOOK-UP NI-vr23A 3/"* NI-VI22A "NT 1/2" NI-Vl29A NI-VI24A NI-VII!iI 1 "'1.0 '" _lFo..o <_ 30;:2.'~0~J_ J ,.r"I.!./2..:t,~.. ~--1.~)J. So-V96 ' ----.....,;'.."-*--,1 SO-V97 ~ i ~ '3'4-!~ FIELO F NI-VI26A N2 MANIFOLD F G NI-VI2'A 1/2-BLOWOQWN BL""",," NITROGEN MANIFOLD FOR STEAM GE!'£RATOR 'A' E E NOTES D ~ I spco. I 1~/4" II I" --------.,. __J~-2.20~O~I_J --""""""--j -il---...,........--'_~~6~!E-~_/ "l1-V29 RC-VI6B I. VALVE POSITIONS SHOWN FOR REFERENCE ON.. Y

  • ACTUAL POSITIONS CONTROLLED BY PROCEOl...RES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL OATA C()\\lTROLLEO BY GMS2. 4. THE NITROGEN MANIFOLDS SHALL BE ISOLATED ANO REMOVED FROM SERvICE PRIOR TO PLANT START-LP INCLUDING CONNECTION POINTS TO EXISTING PLANT SYSTEMS. D ~I c CAO FILE, '11[,8,21,1002.001-,0201 THIS IS A CC>>PUTER GEI\\f:RATEO OWG. DO NOT REVISE IT MAI'AJALLY ~ r--------------------ll'll ~ r w ~_"/2' ..... _J---- HS-V64B - 302-~1 ~Fii -, n _J ~ ALTERNATE HOOK -UP "NT NI-VI28e 1/2" NI-V-124B NI-VII96 NI-VI268 N2 MANIFQ.O---r-- FIELD !~!! I I I NJ-"'06 IBJ IBJ 'W' 1/2' '-:~IG Nl-" N'-" I 1'V'j--('~~ -..... - J~_"E-2.'@::fJ~) MS-V64S FIELD F NI-VI278 6l0WDOWN 1/2-N2 MANIFOLO B c BLO"",," NITROGEN MANIFOLD FOR STEAM GENERATOR 'e' I*.HIZKD 03/20/93 Nuclear/ GAl ~ J02-oo2 302=OOl

~:;l

,;.q;;;mp ~.~ ~ClEAR PLT. NITROGEN SPLY* FLOW DIAGRAM OTSG L. P. NITROGEN MANIFOLDS I A REV. 2 NONE 302-723 TMI UNIT I Ef'<<>.I£CH. MANAGER APPROVAL 2 TITl.E REFER[N:£S COfof>Ot£NT" SYS ID INDEX SYMBO....S INSTRI..foENTATlON SYIeOL..S FLO'W DIAGRAM NO. 3 4 5 6 7 8 A

G H DESCRIPTION REVISED TO (1) INCORPORATE ECR-07-00544 REV, 0 AND (2) TO INCORPORATE AN ADt.lINISTRATlVE RE\\'tSION. ~;I Z:~ INTERWEDIATE BlDG. TURBINE BLDG. "'lD LR-Vl5 SE' O,-NOTE I ':L 'V LA-VI? PORTABLE VENDOR SUPPLIED AIR COMPRESSORS 1---------------------------------------------------------------------------------------------------------------------------- 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 IG I,, I I,, I

H I

I,, I F LR-VZ<4 LR-VZ6 LR-V27 LR-V29 LR-VJO LR-V31 LR-V32 B'UNO FlANGE F"ROM SECONDARY SER\\r1CE COOUNG SYSTEM CLOSED CYCLE SEE DWG 302-221 TO SECONDARY SER\\r1CE COOLING SYSTEl.l CLOSED CYCLE SEE DWG 302-221 c E o

3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
1. VALVE POSITION SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREfiXED BY no' SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
11. LEAK RATE TEST VALVES ASSOCIATED WITH THE HYDROGEN RECOMBINER SYSTEM HAVE BEEN RELOCATED TO 302-722.

4. ALL SUPPORT SYSTEMS ARE SEISMIC CLASS III UNLESS OTHERWISE NOTED.

5. NO INSULATION IS REQUIRED THROUGHOUT.
6. PENETRAliON NO.

417 PROCESS PIPE IS 5CH. 80

7. PENETRATlON NO. 414 PROCESS PIPE IS SCH. 40.

8. LEAK RATE TEST AIR DRYER IS SEISMICALLY RESTAINED (REF. ECM-53).

9. CAP CONFIGURATlON IS ACCEPTABLE AND IS AN ALTERNATIVE CONFIGURATION FOR FLANGES UPSTREAM OF CHECK VALVES LR-V15 THRU LR-V23.

10. THE SPECTACLE FLANGE IS IN THE BLANK POSITION EXCEPT DURING ILRT. NOTES: SYSTEM DESIGN BASIS-SEISMIC CLASS I, EXCEPT AS NOTED. '20' y LEAK RATE TEST AIR DRYER LR-Q-l CR-VOB 3/4" LR-V62 1/2" "30' 1/2" LR-Vll 3/." y WASTE LR-vec ~ 7g ~o 3/4" 53' CR-"fS I Y ,({SEE NOTE 3)) BUND ill SPECTACLE 8 FlANGE SEE NOTE TO ....TMOSPHERE RB pp-~ I-------{D----LI INSIOE OUTSIDE" CO",,,.",", I C(',""""T I I

~:,

T:m L IY 'I LR-VlD -:I I I 80.0 FlC c I,, I, 'E I I I I [ I I I, iD I,, I B ICad F"lIe Nome :302725..R2D I~ THIS IS A COMPUTER ?~~E~~\\~~ ~~~~~'~A~?vl AmerGen N/A 120 302*725 SCAlE: NONE I"'" "''0'" 07/"/07 1CONTAINMENT VESSEL LEAK ..w RATE TEST IA FLOW DIAGRAM COMPONENT & SYS ID INDEX SYMBOLS INSTRU~ENTAnON SYMBOLS FlOW DIAGRAM 3 302-003 2 302-002 1 302-001 No.1 DWG. NO. IA 2 3 4 8 I 7 I 6 I 5 L

8 H G F E D c ~ ij B ~o I I * ~ ~, A ~; Ii .U-8 im ~ ~ I EAST 2 0 ECJ.JIPl£NT DRAIN ~ 3 ~ / 7 6 17 I ~ rn WALL I I l1 ~ c l 0 E 7 PDQ. ' F I G I o*~ I WEST WALL 02 " " " " ~ ~ ~ ~ F1.£t. TRA.NSfER CANA.L INSIDE REACTOR BUILDING 7 6 5 ~o: 0 p 2 0 07 "Lr) 20 EOUJPMENT DRAIN SPENT F"lJEL POOLS 5

12 23 "

n " 20 0 s R I r/ 25 26 L__J 4 3 EAST 'ltALL 25 - ~ UNE NO. ~ T I' § - ~ 26 ~ WEST WALL SEE NOTE 8 27 28 lZ9 JO JI 32 WEST SIDE OF N'.lRTH WALL. t<<RTH [fl(! OF EAST lt-'LL, FLOOR /'£AR CHAl'EL A. [AST SIDE CF N'.IRTH WALL, NORTH E/'CI OF WEST WALL, FLOOR t£AR CHAl'EL A. NORTH END CF EAST WALL. NORTH WALL Of EAST HAUICH. FLOOR NEAR C>WIEL 8. EAST WALL OVER NORTH ENO Of EAST HAl..N:H, NORTH [fl() OF FLOOR ON Ta:> CF CF EAST HAL.N:H. NORTH [I'll) OF WEST WALL OF EAST HAUNOI, FLOOR ON TOP OF EAST HAl.M:H, FLOOR NEAR DWflEL C. F"LOOR f'EA.R CHA.Nl'EL D

  • Fl.DOR f'EAA CHA.Nl'EL E
  • NOR TH El'V OF EAST WALL OF WEST HA.UNCH, FLOOR ON TOP OF WEST HA.l.N:H, FLOOA NEAR (;li.f.llNEL F, Jl<<lRTH El'V OF WEST WALL, t<<lRTH WALL OF WEST HAL.K:H. FLOOR l'EAA CHA.f'.N::L G, 10 WEST WALL O\\IER Jl<<lRTH El'V OF WEST HA.LNCH, NORTH Ef'IJ OF FLOOR ON TOP OF WEST HA.LK:H.

11 CENTER Of EA.ST WALL OF WEST H/\\l.NCH, FLOOR ON TOP OF WEST HA.t.N:H. FLOOR l'EAR CMA.NEL H. 12 CENTER OF WEST WALL OF EA.ST HAI.NCH, FLOOR ON TOP OF EA.ST HA.I.NCH, FLOOR 1'£AA CHAt-NEL I. IJ FLOOR t£AA ~L .J, I* WEST WALL OVER SOUTH ENO OF WEST HAL.K:H, SOUTH EflO OF Fl.DOR ON TOP OF WEST HALt01. 1:1 SOUTH EN:l OF EAST WALL OF WEST HA.UNCH, FLOOR ON TOP OF WEST HAL.NCH, FLOOR NEAR C>Wf'EL I(. 16 SOOTH EN) OF WEST WALL OF EAST HALN'.>I. FLOOR ON TOP OF EA.ST HA.l.NCH, FLOOR t£AA CHA.tf'E'.L L. l7 EA.ST WA.U. OVER SOUTH EKl OF EAST HAl.N:H, SOUTH Ef'IJ OF FLOOR ON TOP OF EAST HALtCH. 18 SOOTH El<l OF EAST WALL OF POOL A. fL(X)R 1'£AR O!ANEL H. 19 SOUTH WALL OF EAST IW..N'.li. SOUTH EN:l OF FLOOR ON TOP OF EAST HALN:H.FLOOA t..cAR OWl'EL N. FLOOR 1£AR CHANtEL 0

  • 2 1 SOOTH WALL OVER WEST HALN:H. SOUTH ENl OF FLOOR ON TOP OF WEST HAL.N:H. FLOOR '-EAR C>IA.N'L P.

22 FlL'.lOR /'EAR CHMtEL Q, SClJTH ENl OF 'WEST WA.U. OF POOL A. FLOOR /'£AA CHANEL R. 24 FL~ NEAR CHANEL S. 2:1 EAST SIDE OF' SOUTH WALL OF POOL.. A., SOUTH EN:! OF EA.ST WAlL OF' POOL A.FLOOR NEAA CHA.toNl. T. 29 32 36 37 38 OPENI NG IN WALL BETWEEN POOLS A &. 8. NORTH OF WATER GATE. WEST SIDE CF SOJTH WALL OF POil... A., SOUTH EN:! OF WEST WALL OF POCl. A.FLOOR !£AA CHNoN1 T, OPENlt.C IN WAlL BETWEEN POOLS A &. B, NORTH OF WATER GATE. EAST SIDE D"" NORTH WA.LL OF' POCl. B ** NORTH EN:! OF EAST WALL OF POCl. B.FLOOR "-EAR CHAl'-l'£L U. O?ENlt.G IN WAl..L BETWEEN POOLS A &. B. SOJTH OF' WATER GATE. WEST SIDE OF NORTH WALL OF POOL.. 8., NORTH EN:l OF WEST WAlL O"" POOL.. 8.FLOOR "-EAR C~L U. OPENlt<G IN WALL BETWEEN POOLS A &. 8. SCJUTH OF WATER GATE. WEST WALL OF POCl.. 8. FLOOR NEAR CHMH::L V. WALLS Al'V FLOOR IN SPENT FUEL SHIPPING CA.SK LOA.DING PIT. WEST El'V OF SOOTH WALL OF" POOL B. SOJTH El'V OF WEST WALL OF POOL B. Fl.DOA 1'£AR CH~ W. SOOTH ENl OF WEST WALL OF POOL B. FLOOR l'EAA CH.........e:L X, FLOOR tEAR CHANl'£L Y. EAST ENl OF SOOTH WALL OF POOL B. SQJTH EN:! OF EAST WA.LL OF POOL.. B. FLOOR tEAR CH>.l+EL AA. NORTH EK> Of EAST WALL Of" POOL B. FLOOR !'EAR CH~L 88, CENTER CF EAST WALL OF PCQ. B. FLOOR NEAR CHMNEL CC. SOUTH Et<<> CF EAST WAU. Of POOL B. FLLXIR '-EAR D-IAtff::L CO. NORTl-£AST CORNER WALLS AN'.l FLOOR OF F!£1. TRANSFER CANAL. NORTHWEST CORt£R WAL.LS AN'.l FLOCR OF FUEL TRANSFER CANAL.

  • I SClJTHWEST CCRt£R WALLS AN'.l FLOOR OF Fl.EL TRANSFER CANAL.
  • 2 SOUTl-E:AST CCRt<ER WALLS AM'.l FL OCR Of FUEL TRANSF"ER CANAL.

302-003 COMPONENT &. SYS TO INDEX 302-002 SY"'8CX..S INSTl'ruMENTATION I 302-001 SYMBOLS FLOW DIAGRAM NO. owe. NO. TITLE REFEREtaS 4 3 2 REVIS I CNS OESCAIPTION REVISED PER1 AOMINIS~ATIQll OiANGE ~ REDRAWN I N CAOAM H E EOUIPl-£NT [)RA.IN 2

NOTES,
1. VALVE POSITIONS SHOWN FDR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL ANO FDR REFERENCE Ol>L Y. ACTUAL DATA CONTRO....LED BY GMS2.

-4. SYSTEM CLEANING REOUIREMENTSIFOR ERECTION ONLY) ALL LINES COMMERCIALLY CLEAN. 5, FLUSH g, HYDRO TEST PRESSURE 25 PSIG, (BEFORE I NSTALLATION OF FLOOR LINER),

6. MAX. AIR TEST PRESSURE ON CHANNELS-0.25 PSIG.
7. All LEAK DETECTION LINES ARE Jt-4
  • GAL LINE SPEC.

150-2. 8, ENDS OF ALL LINES PROVIDED WITH FITTING FOR PRESSURE TESTING,

9. ALL LINES ARE NON-NUCLEAR CLASS, SEISMIC CLASS III.

D c (,J 0 II} CAD FILE t VIE.~2.2 1.1000.001-,0101 I THIS IS A O'.M"l.ITER G8£RATED DWG. 00 ""'TREVIS( IT MANJALLY ....J ~~~~~~~~~~~~~~~~~~~~~--1~ Nuclear; GAI

8 I 7 I 6 I 5 1 4 I 3 I 2 I RE\\IISIONS REV I ZONE I DESCRIPTION 3 IVARIESj REVlSED TO INCORP. £CO-C306236 & ADMIN. REV TO CHANGE TEXT SIZE


1 L

GI H F I-I- I-1/4" 00 ~RMA9-V9 TR 0 BUBBLER RMA9-RM-CED828 FI392A SAMPLE PANEL RM-A9 RMA9-V1O 302-832(G-3) 1--------------------1 1/4" 00 RMA9-V8 I ~A~T~lLU I RM~9-V71' 1"1 1'_ RMA9 ~ V6 1/2" DD 1/2" 00 ~F


~

~ lJ RM-Fll RM-P4


l

(,t) ~T 1". / RMA9-Vl -~-~--! i I I ~ RMA9-Vll S-=~~W,TItLTlI ' 1/4" 00 I a _ 9 I ~,,-"' j /lit. ~ L ~'3/4" 3/4" RMA9-V4 302-832(G-3) 1" 00 IpARTlCULATE1 I----L~-@-- I 1641 3/4" 1" 00 Rt.4A9-V3 RM- ~ 3/4"1 FIl231 ~R~~9-f 3/4" 3/4" ~ L-r---- J~~_JJ__ I_L~_-"- i~ 302-841(G-7) 1" I I ~ RMA8-Vll ~ I at-I L RMAB-V12 s-=~~~;~tfLt, 1 ~~g~~-'


~

SAMPLE PANEL RM-A8


1 I

RMA8-V8 INLET I ll_O...:1/'4~"~0~D~*-.,-..~----'r~ARINELlII I I I I 0 1'_ RMA8-, I ~ V6 I I 1/4" 00 '/2" 00 1/2" 00 1/2" 00 RM-F1D I n 1/2" 00 -lJ RM-P3 ---l / RMA8-Vl 1" y PI 1644 1 1" I-- 1" RMAB-V4 ~3/4" 3/4" PARTICULATE I -!-_I_~~- ~ 3/4" 302-841(0-7) 1>> 00 1" 00 R~~8-RM-I ,J/4"t F112,J0 \\ GAS ISAMPLER r---1 R~~8-f 3/4" 3/4" ~ LO~I~E_I I----'---~-I-I~ F H G CABINET RM,A8 80'!'I~T CABINET RM-A9 8U'1j'~T E 3/8" 00 TO VA-V57 302-131(G-5) E o t-I<- -302-832(G-3>> RM-V46 ,~" ~ RM-V43 )1 RM-F9 RM-FI1250 RM-F8 RM-V45 ,~" ~ RM-V42 ) RM-FI1249 RM-F7 I, ~ RM-RM-~RM-V34 I RM-V35 V32 RM-V36 V33 RM-V37 I RM-RM-RM-V40 I L V38 V39 I ---.J 1/4" 1/4" 1/4" 00 00 00 t RM-IFI1248 RM-V44. I RM-V41 F I 1/4" 00 36B" I RM-P2 I, 302-841lH=7} 1/4" 00 3/8"00 I I RM-Pl RM-RM-RM-(11245 RM-V29 Fli246 RM-V30 FI1247 RM-V31 I I I RM-v26 F RM-V27 F I I RM-F4 RM-F5 I I RM-RM-RM-V19 I V17 V18 I I ~~3 ~~4 RM-V25 I L_____ ~ '/4" 1/4" 1/4" 00 aD 00 1----------------------- I RM-V16 1 1/4" 00 S I

FI~~4-2 FI~~4-3 FI~~44 I,,

I, I I RM-V2 '-......-t)<8)) ~~-,-........,t)<8)) L_____ 1/4" 1/4" 1/4" 00 00 00 o 1/4" 00 I RMA5-V6'" RMA5-V4 RMAS-V7" RMA5-V5" F~~:05C-~ ~~terB-c h ~ z 9 I'N/A 1"3 730 TMI.1 ID~. N°*302 SCAlE: NONE 02/0~{~8 "Z-II A f8 ~"{1f

1. VALVE POSmON SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWlSE NOTED.

3. SET POINT VALUES FOR REliEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY ACTUAL DATA CONTROLLED BY GMS2.

INTERFACING CONCURRENCE C.N o N I ~ Cod File Nome: 30Z720 R3 I~ I-;;; I------"'T":=------------i" THIS IS A COMPUTER ,I~__ Z ~~~E~;~~ ~:~~~~A~~YI\\ ~A. I GAl ~ ~" RADIATION MONITORING & SAMPLING I-FLOW DIAGRAM A SAMPLING PANEL DETAilS NOTES: COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM ~M"cE~7n RM-A9 (MAP 52~,J 1/Z" 00 OWG. NO. 302--003 30Z-002 302-001 '0 30Z-83Z\\G-3 ~RM-CE-0762 RM-A8 (MAP 5) ~ 1/2" 00 ~ I, I ~ 302-841(G-7 RMA5-V8 >1 OUTLET 1/4" OD 1/4" a r RMA5-V2 1/4" 00 >INLET PARTICULA TE &IOOINE SAMPLE RMA5-FI39DA RMAS-V3" SAMPLE PANEL RM-A5 ~ ~ 1/4" OD ~ >INLET CONDENSER GAS SAMPLE 51 OUTLET 1/4" OD 1/4" 00 1/4" 00 TRITIUM ~ I BUBBLER RM-CE0826 1/2" 00 L- __ .. t RMA5-Vl 1/2" 00 RMA5-V9, / 2" 00.l 1/4" 00 1 v, FROM VA-V29 302 n1(F 5) TO VA-v17 302-131(F-4) 302-=T31(C-5) A B c 8 I 7 I 6 I 5 T 4 I 3 I 2 I

(b) (5)

f.l H *-- .r I ~~ ~ M ~ ~f ~

,,~

2 ~!1 i

  • ~~

-~... ~ ~

  • I

~ t I -~ ~ ~ z: = ._L l . i ~. B

  • ~
  • !a f

{!". ! g n o.. I l r f T ,j r _J__j__....::...J.._--1-__ µ l I m ' ~ --i /

  • - r '

' l

  • ~

ci *. t r*

--{

-G ii ; ~ ~ a **.

  • 11111 F

l J I'

11-----------------------------------------------------------------------------------------------------------------------------------, I 8 7 6 5 4 3 2 RE"SIONS 1 i

H i GI F I I

'E I I I I 1 I I D c !s I I I I IA SIGHTGLASS lf / I GW-T-1 EXPANSION TANK 1" 1/2" GW-V48 I l+I ~ DRAIN 3" GW-XJ44C I L_ s ~1/2" GW-V45 GW-P-1C GLYCOL PUMP (STANO BY) WATER v I VENT VALVE GW-V49 y1*" l 3" 7 1" ,.. C]--i' GW-P-18 GLYCOL PUMP 3" FROM DOMESTIC WATER 302-160(G-5) FROM DO-V78 ( 302 B35(F-8) I b* GW-P-1A GLYCOL PUMP 6 ABOVEGROUND] UNDERGROUND I ABOVEGROUND 3" GW-V6A GW-VSA 1/2" GW-V46 ABOVEGROUND I UNDERGROUND GW-V7C GW-XJ46C GW-V4A 5 GW-C-1C CHILLER (STAND BY) 4" 3" 3" 4 GW-C-18 CHILLER GW-XJ478 GW-XJ46A UNDERGROUND I ABOVEGROUND 3" GW-V12A 3" FS 1116A 302-835(H-3) GW-V47 GW-XJ47A GW-C-1A CHILLER J02-00:S COMPONENT & SYS 10 INDEX J02-002 S'l'MBOLS INSTRUMENTATION J02-001 S'l'MBOLS FLOW DIAGRAM DWG. NO. REFERENCES 3 2 REV f ZONE I DE::>\\..t'lll"' u<.A~ 6 IVARlESIADMINlSTRATIVE REV. TO CORRECT EDITORIAL ERROR. CHANGED AH-FC-1115A/C TO READ AS GW-FC-1115A/C. (REF AR 02472901) NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CON TROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.

H IG IF E I I I D c ~ 91 I ~I I I Cad FRe Name :J028J4 RB I~ THIS IS A COMPUTER GENERATED DRAWING 00 NOT REVISE IT MANUALLY Exelon. Nuclear GLYCOL WATER FLOW DIAGRAM OPERATIONS SUPPORT FACILITY TMl*1 302-834 SCALE: NONE .p.

L! r

~ A N/~IR~ ___________ _J

H I

G ,F I I I I 'E I D c B A ~ ~ 8 7 6 5 4 3 2 REVlS10NS REV I ZONE DESCRIPTION REVISE!) TO \\1) INCORPORATE ECR-OB-007ZD R~V. 0 AND (2) TO INCORPORATE AN ADMINISTRATI\\'£ REVISlON. H 4' I V WATER 302 834 E 2 VENT VALVE L. GW-V19S 4" r-2 1/2" 3/4" 3/4~ GW-V50 r;-;'1 WATER V VENT GW-V14 '--' VALVE 3/4" 4" 4" 3" 3" 2 1 2" G \\ GW-V15 3/4" 2 1/2" 2" m GW-T-3 III \\ GW-V16A 3/4" 3" aYPASS FEEDER ) 3" 2 1/2" 2" 3* 2 1/2" 2 1/2" 21/2* w I GW-V168 3/4" \\ \\] ~ Y 2 1/2* TO AIR SEPARATOR 4" GW-T-2 4" DRAIN DRAIN GW-V28C GW-V40 2* GW-V28A GW-V28B 302 834(F 6) F 3" GW-V29 GW-V30 GW-V27,&D GW-V17C GW-V39 GW-V36 rDGW-V27A GW-V17A rD GW-V278 GW-V17B 2" 2 1 2" 2 1/2* 3" 2 1/2" 2 1/2" 2 1/2" 2" 2 1 2" 3" ] ] \\'1 (1) 1 1/2" 2* 2" 1 1/2" 2" ~ GW-V18C ~


i

~ ~ ~ @-------1 ~ GW-V32A GW-V32B GW-V348 GW-V32C GW-V34C FC

{-1 Fe
{-1 FC

}l GW-V18A Fe

{-1 GW-V188 llBC 1119 1118A 11188 TEST TEST TEST 1 1/2" TX TX TX GW-V19C WATER GW-V19A WATER 10BOA 1080B lOBOC

-t"J VENT v VENT 3/4" VALVE ~ 3/4" '--' VALVE ~ 2" 2" 2* 2" 2" 2* GW-V35A TEST GW-V358 TEST GW-V35C TEST 0§@Jt~~ING PO GW-V25C MODULATING GW-V37 MODULATING 7, GW-V25A 7, GW-V258 PX PX 2" CONTROL PO ",...,1 1/2 CONTROL PO 2" PO 2" 1/4~ 1/4T 1269B 1/4"'T 12S9C v 'J'1)'R.l ~~':.\\\\:26A ~ ~ GW-V26C VALVE TEST TEST TEST GW-V38 U n D 2" 2" 1 1/2" 2* 2" 2" 2" 2" ,~, t'" i l L~ S 1/2" L ~2 1/2" S 1/2" 1" 1" 5 1" 2 1/2" 2" 2 1/2" TEST GW-V31A TEST GW-V318 TEST GW-V31C PX PX PX 1/4H GW-S-2C GW-S-3 GW-S-2A ~20A GW-S-2B ~20E ~'i74"

{-1 GW-V33A 12688 ~'/4"

\\:{-1 GW-V338 1268C * (:{-1 GW-V33C '~V20C ~200 3/4" 3/4" 3/4" WAT" WAT£R WATER WATER VENT VENT TI VENT VENT GW GW GW TI VALVE TI TI VALVE n VALVE TI TI VALVE '] 1~1A 1~1B ~ J------- 1~1c 1078C g v 1077e 10780 v 10770 1078A V 1077A 10788 V 0 ~$ 1" 1" 1~ PI G~~7/4" ~ 1/4Q,W-V22C PI GW-V23D ~ *1 GW-Y22D GW-V23A ~~ GW-V22A GW-V23B GW-V22B PI 1/4" ~ 1/2" 1/4" PI PI ~L 1/1 PI PI 1/4" ~ 1/4""-'/1 1267C Vf',J l3 -v;'f 1266C 12670 -vr- -v;'f 1266D 1267 /f'1/4" 1/4"Vf' 1266 12678 'f Vf' ~ 3/4" 3/4")<' GW-V448~ 3/4~ ---- 3/4" ~ 3/4" 3/4~ 11/ 2" ¢ 1/2" 1/2" ~'~r 1'"-"" r 1~"'1 r 1~ J 1'1'" CJ CJ CJ (1) (1) 5 5 E D GW-V21G GW-V21A AH-E-146 AH-E-152 AH-E-154 GW-E-1A GW-E-18 GW-E-1C GW-V21D GW-V21F 1 AH-E-148 1)71 AIR HANDLING UNIT If, GW-V21E AIR HANDLING UNIT 1/2::n'/V r2r ~ "1 GW-V218 AIR HANDLING UNIT f(, 101 r?, AIR HANDLING UNIT Ifv ~=fJ AIR CQNDITlONING AIR CONDITIONING AIR CONDITlONING UNIT UNIT UNIT 8 7 6 ,~ Y FLOOR DRAIN 5 T "fjSJ.. NOTES y FLOOR DRAIN

1. VALVE POSITlONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITlONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES ~

TO 8E FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE, 4 (2) 5 I--" 2" 2" A NO, 3 302-002 302-001 COMPONENT &. SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM REFERENCES ~1:v'" Y FLOOR DRAIN 1 1/4" y OOR AIN c ~I ~ I Cod File Nome :302835-fi5 lUI 2 THIS IS A COMPUTER GENERATED DRAWING DO Am Gen NOT REViSE IT MANUALLY er GLYCOL WATER FLOW DIAGRAM 302-835 SCAI.E;NONE A N/A 15

8 7 6 5 4 3 2 REVISIONS REv IZONE I DESCRlPllQN N/AI REVlSED TO INCORPORATE ECO-C300955 HI IH ~, In, ro, o G 302 841(H 6) )N~R-,=-OC~ 1 I A:~-V23 @J n IA-VIR09 IN$TR AIR C~~--<O-U--<>T--!"h-O-< 302 278(G

1) I NO v,'J o TO 36000 CFM G

F I ~

  • '-----,WOO TO 12500 CFM

~ AH-D-223 -+-r:.-~~~~ AH-D-86 FAIL CLOSED F SECT. 1 SECT 2 E 1 VALV[ POSITIONS SHOWN FOR REFERENCE QNLY ACTUAL POSITIONS CONTROLLED BY PROCEDURES. 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED D NOTES SECT. 2


~

I I I I I I I I I I I~ FOR DETAIL I SEE OWG. 302-841 I I I I I I I I I


~

L SECT, 1 3000 CFM 1------- ~--:I-:-~--,l-l f---i AH-F-2A it n AH-F-2B it

L

-.-J:

L

-.-J : SEE Dwe I ---J L I f 302-694 I FOR CONT'N. - f- --- --- -f -T --- -....------ FROM RELIEF' t I VALVES I I

1-----, :
1-----, :

tJ AH-F-2C ~j tJ AH-F-2D IJ I I I I I

'""'~~.. LT-.J __ L~J-.J

~, eo Z g AH-O-212 $-11 FD-62A 4" PVC FROM HITTMAN PORTABLE SRW SYSTEM 302 692 (E 6) D E c 4000 TO 12500 CFM 8000 TO 44000 CFM WALL AH-D-224 IA-VIB08 TO REMOTE SENSOR wASTE DRUMMING AREAr----j----l I I I I I I ~AH-D-202 I FAIL CLOSED I L ( t- - - - 302 841(H 6) I I INSTR. AIR 302 278(G 1) TO REMOTE SENSOR VENT. EOUIP ROOM c B O~{N~tAG~O~O Ii' EQUIP. ROOM AH-D-222 VENT. (QUIP. RM VENT. SUPPLY FAN AH-E-t28 3000 CFM PLENUM VENT EQUIP. ROOM FL EL 305'-0" MAKE-UP AIR TUNNEL -Ar--- 8000 TO 44000 CFM AIR INTAKE TUNNEL eNa IV FFi,e Nome: 302840 R7 ~ I~ a AUXILARY AND FUEL HANDLING BUILDINGS VENTILATION FLOW DIAGRAM I I A 302-003 302-002 302-001 owe. NO COMPONENT & $YS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM THIS 1$ A COMPUTER I~ __ GENERATED DRAWING DO \\ GPU NOT REVISE IT MANUALLY .ClCUAa INTERFACING CONCURRENCE / GAl 302-840 7 A REFERENCES 8 7 6 5 4 3 2

r--------- I I I RM-A8 (MAPS 302-730(0-4' RM-AB (MAP5 .3D2-730(C-6) TO AH-V23 C}Q?:-84-0(G-7) I I I AUXILIARY BUiLDING CLASS, S-II(EXCEPT AS NOTED) 4 FROM WASTt r "'C o~":""" g EQUIPMENT TO THIS POINT BY OTHERS L 4-- {-,~'jUL) TO AH-E-1O t --- -TO AH-O-14A __ O I L----TOFIRESYSTEM 4 (aY OTHERS) --~ H-D-l~ AH-O-24 -e FUEL HANDLING BUILDING NOTES

1. VAL~ POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITlONS CONTROLLED BY PROCEDURES 2

ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED * .3 THE DIESEL GENERATOR SYSTEMS HAVE BEEN RELOCATED TO DRA\\\\I1NG 302-844. 4-. AIR FLOW RATES ARE BASED ON RESULTS OF CALCULATION C-l101-S29-5360-003

5. THE FOLLOWING INSTRUMENTS ARE INSTALLED SPARE5 BUT NOT CONNECTED AH-TS-841A/B, AH-TS-84-3AjEl, AH-T5-845A/8, AH-T5-847A/8

-'INl'tRfAaNGCotlCURR£N!;f -~--~--~

H G F E D c B A 8 I 7 AH-E -203 SUPPLY I 1 1 1 1 1 1 1 1 1 1 ~I AH-C-SAB I 6 I 302 231 SH.2 (E 4)>-- --@ S---TOFIRESYSTEM 848 A-H r------- SEE OfE~AIL "A" (A-3) I DPS I 571/ /' 1 1 P A C~

ulJ,

\\A~ / AH-0-42A STATlC PRESS. SENSOR & METER (TYP) \\ l-A \\ 100% CAP. AH-E-18A EMERGENCY DUTY SUPPLY FAN 5 CHILLED WATER SUPPLY (302-847) l 1 1 1 1 1 1 1 1 1 4 I 3 J 2 I REVISIONS REV ZONE DESCRIPTlON 571 [-8 I REVISED TO INCORPORATE ECR-09-00037 REV. 0 H P AH-0-40A -J::@ l3~ FD;26 EH/e AH-D-41A r------,----~~ ~~~~~p~----~ 1- -;$~: N ~ ~'~A - -.lT~7 1 (, 727 I AH-C-6A fo-....l... __ I ____....I ____.-Ic AH-0-32A AH-~-584 S-J (SEE f' NOTE ~_ ~~ TC AH-O-270 IN~tKE r I 734 ~ FD-29 J~~~J1----~~--+--A-H~-~0--3-9--""--------~~ AH-D-605 T~A-------i I JJ!0 FD-32 ~

:~

,,~:,:1 Q~ I AH-E-94A ~ FROM CONTROL I I ~RBlDG HALL I AH-O-878

A~

r?~ J I I HI~ 1 L __..J~ L ______ ~ I ANiFs\\ ~ /DAMPER BLADES REMOVED AH-D-36 FS 196 ~ ___ ~H~r:::-~A_ AH-E-17A I I C FO-27 rfrl' ---1 1 DPI T '- ____.l. _ J 695 I L ______________.-I FS 197 NORMAL DUTY Gt,s; N SUPPLY FANS TS 69 0 AH-E-178 r ____ ~ ~ - - -D~ - 872 1-----'---------------------------------------------------------------------------------------------------------.. ~ 1,- - -l 1 ~ 1.. ~FD-28 I ~ 1'?1 Ali::.E=.+/-S. I I II\\Cl Y FD-30 ~ ~B-Ilkc~-~.~~A~~~~---~-~~-----------------~------~ ~tG~T~8 FI ~~ AH-C-68 Qh: ~ AH-0-40B1i::F_38 '\\ 835 J 1 ~~;;; - 7'f8 1 "-____ ;'/~~~~~~~-;; AH-0-428 1 EH/C ~C ___ ----.l

,fi ps\\, /IJ P

AH~E~'88 CHILLED I 572 I I EMERGENCY DUTY SUPPL~;b~~847) I I I I SUPPLY FAN I 1 SEE OETAIL 'A" 1 / 1 L _ JA.=3L _ _ _ _ __ -.J _ ~ 1 302 231 SH.2 E 41)-- T5 A--H I 849 TO FIRE SYSTEM I ___________________________________ J AH-E-65(S-11) FS 198 i~ 1 1 1 J FD-46 ~ G 1 _I F 1 -I -~ ~------~------,-----------------------------~----------~--~------~--~H 1 1 EH/e 1 AH-C-7C EL. 355'-0" FOURTH FLOOR +AH-O-S90 I~ATMOSPHERE AH-0~38 AH 0 37 \\eUHI (AH-E-204 EXHAUS,)

-~~AN 

'i3;;0'~2~8;-;4=c2"SCCH"";3iCE~3';;'~;_--.J \\2:./LO AH-O-35A FO-24 ~ I - -" -iW" AH-0-585" " AH-D-586!.,., 100% CAP 100" CAP ~ AH-E-19A"Y AH-O-358 'W-l I I .J AH-E-198 37,351 CFM I CORRIDOR FD-2.. 302 842 SH.2 F 4 8 FD-51 '" I EH/C I -40 r -


[ft AH-D-43D 1

1 1 FD-19.. '::l~1 ESAS lOGIC CAB. ROOM 1 1 I-- - ---if}, AH-D-440 AN~ HI~ I I FD-23 I EH/C I -40 I ---; AH-D-43C 1 1 1 1-E 4160V I SWITCHGEAR (B) I 1 1 I-- - - -; AH-O-44C ANJfs\\ HI~ 7 I I AH-0-587" f; STORAGE ROOM AH-~-604 1 EH/C -40 r - - -; AH-D-43B 1 1 1 SWITCHGEAR (A) 1-0 4160V I ...J 1 1 I-- - --{f}; AH-O-44B ANJfs\\ HI~ t 6 FD 47 302 842 SH.2(D 8) FDI EH/C 1 -40 I - - ---If}, AH-D-43A 1 1 1 1 1 1 1 1 FD-21 RELAY ROOM 1 FD-22" I /AH-0-583 /AH-0-582 L - - ---0-; AH-D-44A

~

I 5 TO EL. 338'-6" EL. 38r" TQ..~I.I-~4&..B_ 1 HALLWAY T C ~ FO-57 " f;AH-0-588 6",!vAH-D-589 Ir----'------, AH-C-7D EH /C --=-=;-- .~~ ~~ 1 EH/C I ~ ~ ~ RM A-I E ..---T""""---i ~~H-D-591 ~AH-D-592 ~ AH-D-593 r ,-_--' 1_---, TS AN O~~H-D~-: l~ I AH-O-597 AH-O 596 598 1 1 TS AN AD 1f{NrRAL II (~l~ET) II FO~~:r}N'S OFFICE 795 HI ~AN I ~LO AH-D-88A~~ r --"I ~N ~I I


r J I

r -- --, AH-0-B8BrB-~ -n -+..J.--(]32;o2~B~31~E~4D rs AN FROM O.A. 832 f AH-E-938 SUPPLY TUNNEL CONTROL BUILDING HALLWAY VENT. 4 FS AN 275 LO I 3 302 842 SH.2(H 1 ~~~_~3A --I P He: DPI OPI I 698 699 DPI I 571 I OPS 571 OPT I 571 -~ I' AH-F-38 "'eY ~: DPI I 572 I OPS 572 OPT OPI I ~ 76b I\\@- 572 1 L _______ 57~ {} CONTROL BUILDING UNIT HEATER SYSTEM ~- 5 ELECTRIC UNIT HEATERS 5TH FLR. AH-C----- 22A, - 228, - 22C, - 220, - 22E 302 003 302 002 302 001 DETAIL "A" (G/H-7) COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM REFERENCES I 2 796 HI FD-60 * '" FD-6r. f" AH-D-602 L" ft r AH-O-603 1$ N 7978 HI ANTS TSN HI 97 TS N 97C I 7970 HI

1. VALVE POSITION SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM OESIGNA TOR UNLESS OTHERWISE NOTED.
3. THE FOLLOWING COMPONENTS ARE SEISMIC II-ANTIFALl DOWN:

-AH-E-17A/B AND AH-F-44A/B -AH-C-5A/B; AH-C-7C/F; AH-C~8A/D; AH-C~9A/G ~AH-E-21 AND AH-C-22A/E ~AH~E-93A/B AND AH-E-94A/B D -I 1 c -"I ~ ~ ! ~~~~~~~==~----------------~~ r£Qd File Nome : 302842 Sl 57 ~ rT-HIS-,S-A-C-OM-PU-IT-R-r------------------~ ~ GENERATED DRAWING DO ...... I h~..

,..K;,;;R~;,;
;;,:E;,;SK;,;;::;,;;M;,;;:;,;;~U;.,,;.,L~;;.:f.:Am:.:C::.O=~;:,T..:R=O:.:L~B-U-IL-D-I-N-G-A-N-D--.. -

1

g;;(~ -&i,).fj MACHINE SHOP VENTILATION A

FLOW DIAGRAM ~(;:. IOWG.NO TMI-1 I 302-842 I" 1 SCALE' NONE I

I I H G F E --I o c I I 8 AH-C-9A I I I I I I BA nERY RM. (B) I 333 CFM I FD-15...... I 1----07 AH-O-31A AN~ TS HI 678 ~0~C_842SH 1(ee5) 473 CFM FO-56 'rE AN 210 I HI ~ E AN AN 212 HI TS 732 HI rB-- L AH-D-29A AUXILARY I I I I FD-14 t AH-C-9B 7 I I I I I I I BATTERY RM. (A) I 250 CFM I 1----07 AH-O-318 ANris\\ HI~ AH-C-l0H I ~ ~ FD-13 I 2ND PLANT SAMPLING & INSTR. ROOM 615 CFM _4132 CFM .-2127 CFM 47480 CFM FD-53...... 14,812 CFM AH-F-6A TO~ ~ BUILDING AH-E ~ EXHAUST B DUCT 100% 30&r:~~1) AN AN -20A CAP. A 8 I 7 I AH-C-9C I ~ ~ I I I EHIC I I I I I I I SA TTERY ~)HARGERS I 1709 CFM I FD-ll +- I 1-- A~ - -IB;f AH-0-OlC HI~ AH-C-l0G 1 1 I I 6 FO-9 !II AH-C-9D ~ \\EV EHIC I I I I I I I I I I BATTERY CHARGERS 227Cf)CFM I- - - -IB;f AH-O-31 0 I 5 AH-C-9E EHIC 1----- I I I I I I I I I I IAH-E-Lv cb AH-~'~9 TECH SUPPORT CENTER OFFICE 532 CFM ~ - - - - -


0-;1" AH-D-31E 1

!II I 4 AH-C-9F EHlc ~ ~ I I I I I I I I I S~~~~E:8~SB) 1115 CFM I 3 AH-C-9G EHIC ~ ~ I I I I I I I I I SWITCHGEAR CA) l-P 480V 1860 CFM 1 2 1 B I 8-7 I REVISED TO INCORPORATE ECR-DS-006B5 REV a AH-O-l01 A FS 76A LO If) 322'-0" SECOND FLOOR AH-E-95A ~ .~~1 ~AN ~ LO AH-E-95B ~ FO-4 '2 842 SH.l(C 2) :- 8,074 CFM 6900 CFM AH-D-617 AH-D-28 FO-55 ~ ~ - AH-O-31F r ------------ ~6~_D8~~ ANris\\ AN~ AH-D-31GI r --_________ (8-8) AN TS AN\\-:c:':-ct-__ -I I HIE" HI 682 HI 683 I I SEE DWG FO-lO FO-8 FD-7 302-231 AH-C-l0E ~ ~ AH-C-l0D I ~ AH-C-l0J EHIC ~I~ ~~ I I I I I I I I I I I I I 7439 CFM 302-842 SH.l(A-8) EL. 306'-0" FIRST FLOOR AH-C-l0K EHIC ~I~ ~~ I I I I I ~~ ~ K, I I ~ I I j L __ I I r ------_.1_..Lii'L_ TO FIRE SYSTEM ~ HOT LAV SHOWER & DRYING 154 CFM + LAUNDRY 440 CFM MEN'S & WOMEN'S TOILETS 158 CFM + A,8 ~ L~ A,B,C 400 CFM AH-C-l0C EHIC ~I~ ~~ LUNCH ROOM 677 CFM AH-C-279 ~ ~ HIC CONTROL POINT ABOVE CEILING INSTRUMENT AIR COMPRESSOR "A" ROOM I SEE DWG - --- - NUCLEAR-SERVICE CLOSED --11 EF=pifAl-EF-~ 3~~=~lD CYCLE COOLING WATER ::-@ I ROOM I ROOM I ~ NS-V55A ~ - N-J~ N 857 i ~",-(I,o i i I I AH-D-616 7800 I ~""'-"'-""'I"""-r-1'...... --. ~ CFM I 5~O-c-;J I A I I ~ _ _ ~ _-_-_-_-_-_-_-___ -J 7T~3 AH-E-90 FD-52 - T ;- l I L- _____ ---.J I FO-69 r-i I H f0 I-f0 G i'- i-F I-E I<- o I-c TO PURGE EXH. DUCT Q I f-302-831 H-6 <C w FIXED PLATE I ~ I I p FROM AIR SUPPLY TUNNEL (DIIO. 302-831) NS~5":'B __ ~-J... _1 ~: 6500 CFM SEEDWG ~ n I - -302-610 I I (F-8) I I I N~CLEAR SERVICE CLOSED I TURf! DRIVEN EMERG. I I 6 I SEE OWG L _________ -' ~ @ AH-E-26 302-231 t TC 764 AH-C-174 NOTES;

1. SEE SHEET 1 FOR GENERAL NOTES.

I 5 T HOT TOOL ROOM AIR HANDLING UNIT 4 ________..1 I 302-003 302 002 302 001 No.1 OWG. NO. 3 L.....CYCLE COOLING WATER ~.W. PUMP ROOM ~ IW I CQd FIIO! NQme : ;'02842 52 R8 ~ COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM TITLE REfERENCES I 2 THIS IS A COMPUTER ~~~E~:~~ ~;AM~~~A~~Y AmerGen CONTROL BUILDING AND ~~~~~ MACHINE SHOP VENTILATION FLOW DIAGRAM ~'I 1'= '" I~ I'~ E" TMI*' 302-842 2 8 ';tt.., *. :lf:1- 'ft/'fJd SCALE: INlERFAONG CONCURRENCE

rA NO.

I W I I-A

G --+ c


~BINEBLDG355'EL CONTR(iBi:Dc:-38~

CONTROL SLOG. 380' EL


CONffiiiBLDc:-3s57EL AH-E-204 CONTROLBLDG.365'EL.

- CONTROLBi:Dc-3"55'El G NOTES: c I I u I 6 8 -=-- -,------;--------,------;--~;---------r--------:---~_fi'

~~ ~~~~~A I

302-001 -~ ?/zsflz-llTLE INTCRFA~ING CONCURRENCE REFE~--

G F ,E iD c B IA 8 AH-E-45 RELIEF ROOF VENTILATOR 6900 CFM 8 TO ATMOS TO ATMOS 7 AH-E-44 RELIEF ROOF VENTILATOR 6500 CFM ROOM 7 OS 620 t t i 1~[ ~~JO


*i-i. EXH 250 AH-E-39 POWER ROOF EXHAUST 740 CFM LS 50 EXH 50

~ . OOM]2g~ GAS) cc EHC AH-E-110A AH-E-1108 7 ROOM 29 OS 1070 LS 1060 RA 2130 RA 2045 6 RELIEF INLET AH-E-38 6 AH-E-43 RELIEF ROOF VENTILATOR 9950 CFM FS 224 5 TO ATMOS. CH-V52 4 4010 CFM 1840 CFM AH-C-11A I EHC I I I I ~CHILLED WATER FOR CONT. SEE DWG. 302-846 SPACE ~ THERMOSTAT \\!§) FS 225 11035 CFM i=-Hc I OFFICE AREA I SUPPLY UNIT AH-E-35 L-~- ~ ~ SPACE THERMOSTAT I I OFFICE AREA RETURN AIR FAN AH-E-36 AH-E-79 d IAH-0-48 _J CHILLED WATER FOR CONT. SEE DWG. 302-846 AH-E-77 O.A. INTAKE 600 CFM MIN 3400 CFM MAX CH-Y53 AIRM~~T~~fTl~~I~~ L I _ ~N~ _A~-~-_:3_ __ ::::::::: J-AH-D-46 0::2800 CFM RELIEF

. lEJ AH-D-47 s.w.

I I I I


1.--Jg~

MEETING ROOM RETURN AIR FAN AH-E-34 5 4 ROOM 40 DS 900 INFILTRATE 2520 CFM SERVICE BLDG. ROOF 2800 CFM 3 I I I LOCKER ROOM j I HEATING SUPPLY UNIT I L - _!~~3~ - - - _J ......... -- FOREMAN'S OFFICES AIR CONDITIONING UNIT AH-C-275 MEETING ROOM ROOM 6 DS 3400 RA 2800 LE 600 3 OWG.No. TECHNICIANS BENCH AREA AH-E-40 POWER ROOF VENTILATOR 600 CFM SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM TlllE 2 ZONE 25 I 5=6* I REV1SED TO INCORPORATE ECR 13-00489 REV. 0 SERVICE BUILDING UNIT HEATER SYSTEM c[] --- ~ 4 H c::::J @i) 5 B D ELECTRIC UNIT HEATERS (5) AH-C-19A, -) 98,-19C,-190, -.19E. BASEBOARD HEATERS (8) AH-C-13A,-13B,-13C,-13D, -13E, -13F,-13G,-13H. CABINET HEATERS (2) AH-C-14,AH-C-15 AH-0-52 2 NOTES POWER ROOF VENTILATOR AH-E-41 POWER ROOF EXHAUSTERS AH-E-42A,-428, -42C MACHINE SHOP PREFIX DESCRIPTION OS - DIRECT SUPPLY LS - LOUVERED SUPPLY LE - LOUVERED EXHAUST RA - RETURN AIR EXH-EXHAUST AIR INF-INFILTRATION EXF-EXFILTRATION

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE.
4. AH-E-31 SUPPLY FAN & AH-E-32 EXHAUST FAN SERVICE THE MENS,LADIES AND SUPERVISORS LOCKER ROOMS AND SHOWERS.
5. AH-E-33 SUPPLY FAN & AH-E-34 EXHAUST FAN SERVICE THE CAFETERIA AREA AND THE PLANT MATERIEL ASSESSMENT OFFICE.
6. ALL OTHER AREAS,HALLWA YS AND OFFICES ARE SERVICED BY THE AH-E-35 MAIN SUPPLY FAN & THE AH-E-36 MAIN EXHAUST FAN.
7. FOR MORE DETAILS SEE GAi DRAW1NG No. E331-001.
8. AH-C-309 SUPPLIES HEAT TO THE TELEPHONE EQUIPMENT ROOM. HEATER CONTROLLED BY AH-TC-779.

Cad File Name: 302843_R25 THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon. Nuclear 25 VENTILATION BUILDING SERVICE BUILDING FLOW DI AGRAM ~ 3/if M TMl-1 302-843 ~N/A 12s INTERFACING CONCURRENCE H G F E D c g: N ~ A

H F IE D c B A I I / ~ ~ 8 7 AH--E 65;~,3---'--CL co AH 34,00U CFW FD O.A. INTAKE 3t,OOO CFivl ~

  • AN cAH~

(ig* I 1-11 \\~A~-E-51 TLJRRII\\E B*JILDING AND HFATER BAY (I Ml 3LOG-0002) FC ~ - I Ari-D-9 I ~ L I I I L ____ - ____________ _j INTAKC PUI,~P ANlJ SCREFN f-'OUSE 8 7 C. A INTAKE 6 ~~ NORT-1 R1\\Dii\\TOR ROC)IV~(ES) CLASS S-1 6 5 4 3 -S-!1-------1 2 C(tV LU~It DESCRIPTION AIR IN-AKE Ar-1-C:-114 ? ,------~-----_Lt_ 1 J02-8J1 -o RB-V19 HOUSF (TMI-BLDC-*JQIJ6) -[___ 322ccS45- (c=6i) 600 CFM Roo=- VENTILATORS WI~HlR ONLY + AH-D-00~3 M -~

-D-904 JI.H-C-40 AH-C-t\\-1 P.H-E-6 1 >SUMMER SW POS-1 COOLING TOVVER I

~ AH-E-123 \\- \\J) 750 U-M I lh I ELEC UNIT --ITR I EXH 18,?gQ~ LS 42,:L9C,-n ELECTRIC UNIT.HEA'ERS ___ 'hJ (7) AH-C-;>{A ~ CYC 1_F.: MAKE UP WATER PRtTREP.Tri~ENT HOJSE ( llvii-BI_DG- 001 5) ~IVFR WA.Tr:-R II'H:".KE (Ti'AI-BLDG- 0009) SJBST ATION ~ELAY CON 1 ROL HO.JSE (Tivii-BLDG-0018) AH* c_gsA & 9do mA::R CJN I ROL 15 MIN. CYCE WALL VENTILA70r1S "593 CFivl ~~lC UNIT HnS. I &~/~~C-3GA & 368 (TMI-BLDG-00?1) I'W~P HOUSE c[J--1 AH-C-281 ELC:C. UNI' !-ITR_] ~-J~W_j PL.-INT EFF~UENT RADIATOI\\ ~~~CNITOR r-1CUSt_ ~,-s--,

~ "-':J 3~AF COOLING T0 1NER VALVEHoUsES C:IRCIJLAIII'\\G VV/\\'ER CHEMiCAL --:-eoDTiiONIJLOc; (Tivii-BLDG-0087)

L_____ -L_JJ 1<-50 Rl~m/ONI-ORS BUI D.f\\JG (':YVER.:JLA.NT V:::\\J T JNNEI) RIVER W.ATFR DIESEL FIRF PU'v1P HOUSE_ 8---r-.,-- bd~~-: ---r-- ~e~-579 ! ! (~ en____ I I y__r-- j L_(ic\\ fi.H-C-272 I \\~o_g) I I I I I I [ J~ '~ S-10,114 XH-1C,114 --- I c-711"-E-99 I{] ~~ \\___/ EXH'ILST CAN L________l_.. [Ji~ 10CC ROOM AH-C-358 [LfC: UN1T HTR INOUST=:('IAL WJI.Sll TREAn1EN I oUICDiNG (TMI-BLDG-JC20) cO--l (~t'") -IH-E=_105_(; 295 CF\\A ChLOR'NAIDRr ~ /::-;:JAH-E-1058 J_) 73-8 CF~A COOM ~ CFM ~---=--'-= WA.LL I~ Sf.-, MAIN TREATMENT AREA vccn1cA 1uR~ ~ _ I Arl-c-o8A,B,c,o ~ I 22ooc~- ~Li] AH-E-1398 SEWAGE TRlATiviLJH PLANT (TMI-BLLJG-ULrl ::i) AH c~1 AH-E I'.H-E-100C FEEDWA TER PUMP PELJEST AL V':_1\\J 1I'_,4,T,ON ) 15,COO C-M t 15,000 CFM 1JIIi::_E_-_:_Ei1f\\ (-~AH-E-_1_618 \\_f/ i/ CO"DENSI'.~E BCOSTER PUMPS PEDESTAL VEI\\'TIL_ATION TJRBI~E BUlL~ PROCC5SED WAE.~ PUMF' HOUSE t '5,000 CFCI 9AH-E-161C NOTES

1. VA.LV':.

POSITlm~S SHO'NI'\\ FOR REFERENCF' ONLY. ACTUAL POSITIONS CONTROLL[.l) IJY PROCEDU'\\F:i 2 AU ~JSnL'MENT T/IG NUM3ERS AR.':: f--'K:TIXED BY SYSTEM DFSIGNATOR Uf\\JL[SS OTHERWISF: NGTC:O

3. ALL SYSTDviS ARE CLASS S-11' UNLESS OTI D~WISE INJICATED.

~ PREFIX DCSCRIP-ICN* H F E D c (_N 0 _________________ N 16 5 L __ _ SOUTII RADIATOR R:JO\\tf -(ES) CLASS S I 4 i--- 1 2 -1' +-

H G F E D WT c1;~ ~lfl ~~ B A 10 FILTERED WAlER 302-169 (G-2 FROM WT-V734 RB-V122" 3/4" RB 10 9 RB-V113 RB-VJB WT SEE NOlE 3 a" 2 1/2" 3" 9 8 J/4"% RB-V16B RB-V14A 3* a* RB-V130 ~ HI 9 +AH-D-201C / i Gi

H ~;,;.HOOD OTE 4 0 7 LO AH-E-89A-D v

8 7 RB-V15B 2,, TO AH-E-73 I 302-844 (G-3) > FROM AH-E-73 302-844 (G-3) TO AH-E-73 I 302-844 {F-6) ) FROM AH-E-73 302-844 (F-6) FROM TC 828 -(302-844 (F-3) I RB-V71 1" RB-V77 7 6 6 TI .9498 a* 2" ..:.. RB-V28 DRAIN -RB-V40 DRAIN 5 FROM PENT #422 302-611 (E-8) TO PENT #421 302-611 (F-8) BANK 1 ! BANK 2 (ii;)"' y AH-D-200~/D ~ VENT. HOOD __;:"' / SEE NOTE 4 AH-D-1a1C/D LS LO ~"~ v AH-E-111C/D RB-V45 5 4 4 3 3/8* 0.D. (TYP} AH-P-12AI v AH-P-128 I ---L ___ --- ---- - ---=-=-=-- J 3/8" O.D. DEMIN. WTR. 302-163 (0-1 FROM DW-V54 J/8H 0.D. RB-V83 RB-V85 AH-P-12CI ---L ____ --- ------ 2 302-003 3o2=0o2 COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION 302-001 SYMBOLS FLOW DIAGRAM 3 2 1 SD IYARIESI REvtSED TO INCORPORA1E ECR 14-00272 REV. 0 NOTES

1. VALVE POSlllONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSlllONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED.
3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA SASE.
4. DAMPERS BLOCKED OPEN PER ECR-07-00582.

H G E D c 1coc1 flle Nome: Ja2l!4!l RGa I~ THIS IS A COMPUlER GENERA TEO DRAWING DO NOT RE\\r1SE IT MANUALLY &ekm. Nuclear i o.1o~INDUSTRIAL COOLER SYSTEM FLOW DI AGRAM I A COOLING WAlER REV. TMl*1 I 302-845 60 SCALE: NONE 1

H G F E jo I le B A 8 7 6 3" 2 1/2" 2 1/2" 3" 2 1/2" 12 1/2' '-D CH-V98 CH-V6A CVCH-V9A 2 1/2" 2 1/2" CH-V52 CH-V53 2" 2" 1/2" 2" 3" 3" CH-V5A CH-V58'XCH-V50 Y CH-V5C 2" 2" 2" 2" 2" 3/4" 3/4" CH-V2G AH - E-35 CH-V2H AH-E- 33 CH-V48 CH-V2E 1----1 1 1/2" J CH - V2D 3" 3/4" CH-V2N CH-V2P '-D CH-VS 8 3" Tl 1019 3/4" CH-XJ-34 CH-XJ-33 3" ~ 4" AH - C-38 t CH - V30 1/4" 2 1 / 2" 12 1 /2" 12 1 /2" 12 1 /2" SC-XJ-298 (TI\\___ ~I 1/2" 7 SC - ~J-29 A t )SC-XJ-30At j SC-XJ-308 1021 3" 3"

  • '3/4" SC - V192 6

VENTr.i3/ 4" 1 1/2" SC-V205 J" 5 4 I 3 I 2 I 1 CH-V68 1/2" 2" CH-V29 1/2" 1/2" 4 ~ o~?i~E PLA TE CH-V12 1" CH-XJ-32 CH-V3C CHILLED WATER CHEMICAL MIX TA ~ K 4" 4" 5 AH - P-5 TO SC-V19 302-2 21 (D - 8) FROM SC-V12 302 221 (E 8) 1" CH-V3A CH-V28 3/4" FILL ANO MAKE-UP WATER 4 3 302-003 302-002 302.::.-001 COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTA TION SYMBOLS FLOW DIAGRAM 2 REVISIONS REV I ZONE DESCRIPTION 21 I C-3 !ADMINISTRA TIVE REVISION TO CORRECT VA LVE TYPE ( IR 2533490) NOTES

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY.

ACTUAL POSI TIONS CONTROLLED BY PROCEDURES 2 ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERW1SE NOTED

3. SET POIN T VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE Cod Fil e Nome: 302846_ R21 H

G F E D c z 0' 0 Co ~ ~ ~I I THIS IS A COMPUTER z GENERATED DRAWING DO Am G NOT RE ~SE IT MANUALL y er en )> CHILLED WATER SERVICE BUILDING A FLOW DIAGRAM ~. TMl-1 302-846 N/ A 121 L ______ __ _ _____ __ ____ __ _____ ____ ___ ___ __ _____ __ ____ ___ _J

8 7 6 5 4 3 2 REVISIONS DESCRIPllON 11 IVARIESI ~~~I~~~T;~TI~~ ~EC~~6~RATE ECD-C500156 AND (2) H H G G F E D c B 2 1/2" C 2" 4" AH-r-12 I" FILL I" A FROM RB-v8A 302 611(G 7) t '5-V290

  • 4"

'$-V304 i:: FS-V291 FS-V293 FS-V340 N I" CHEM MIX TANK FS-T-29 I" £:4 FS-V287 FS-V292 F$-V294 DRAIN SIGHT GLASS I" 4" FS V288 ~ PI 1216A PI 1215 L F$-V297 If 11 /5-V298 2 1/2" 1/2" 1/2" FS-S-69 2 1/2" 2" ( F$-v283 FS-V302 l L:/4" '5-V284 FS-P-5A I FS-V307 I I" I i ---.-~4"VENT i FROM AH-F -12 AUTO L ___ -< START HI TEMP 302 831(G 2) I i 1t C,,,". PI i WATER 12168 I PI STORAGE TANK ~ I 12158 AH-T-1 1I-1186 '\\: F$-V299 I -t 3/4" F$-v306 ~~ 3" 4" I '\\ FS-V300 11 I 2 1/2" 1/2" -.J 1/2" FS+/-70 21/2" U FS-V289 ( \\7 r5-V285I r5-V303 3/4" 2 1/2" ~V'/4" '5-V286 '5-V296 3/4" FS-P-58 FS-V30B DRAIN ~ tFS-V301 rs-V29S DRAIN HOSE CONN[CTION FOR rANK PUMPOUT E D c NOTES: 1 VALVE POSITIONS SHOWN FOR REFERENce ONLY ACTUAL POSITIONS CONTROl.LED BY PROCEDURES. ~\\ 2.

L;S{~~T~~~I~%TAit~ ~~LME~~Rgr~~~
~fF~XJfEDBY

~__:':_......._-.. -_~-_-_ ~_~__,",,-0_ ~ti CO ICad fOie '~"me I I J02841'LRli 11 302-848 THIS 1$ A COMPUTER ~~~E~:~~ ~:~~~~A~~yl AmerGen l!tio~:"""'~' 06(O:{~1 CHARCOAL SPRAY SYSTEM REACTOR BUILDING IA FLOW DIAGRAM COMPONENT & SYS 10 INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 302-003 302-002 302-D"OT A 8 7 6 5 4 3 2

I 8 7 I 8 5 I 4 I 3 I 2 I 1 REVISIONS I I IREV.IZCt£ I DESCRIPTION I ADMINISTRATIVE 0W<<iE TO llof'l.OIENT ~ITIl>o/S. EtfoIANCEloENTS.v<<l 2: N/A c.cRRECTI~ Dl.£ TO RECl-ECKlf'(> OF OWGS F"ROM M,.tHJ,t,L TO CAD FORMA.T H H Oil INT....KE I~OO eFN (MIN) I-GI I I I ---I r F I ILL-I I I I I I I I I I I I I I - I I I I I I F G 285 CFM 2" CFH 326 CFM 122 CFIIl 122CFH 122 CfH 122 CFM 342'5 CFM 0-0- 0-0- 0-0- 0-0- 0-10-10-10 I-E E COIIFERENCE ROOM II COIIFERENCE ROOM '2 COIIFERENCE ROOM '3 LlH:H DAY ROOM CLERK ROOM PHOTO ID ROOM MAIL ROOM calRIDOR CHIEF OFFICE GUARD ROOM PROCESSING AREA 400CFM 3l5O CFM 300 CFM 400 CFM Il)() CFM Il)() CFM Il)() CFM 2l)() CFM Il)()CFM 4200 CFM -t It-

7. CFH 28 CFH

., CFM 28 CFM D 300 CFM D NOTES c -\\ -~ FAN-2200 CFM ¥ IAH-E-84l \\\\\\ \\\\\\\\\\ MENS LOCKERS MENS SHlWERS MEN WOMENS LOCKERS "500 hf'lJoTR~TMION .1 CFM PHYSICAL FITl£SS WOMENS SHOWERS WCJEN UTILITY ROOM I. VALVE POSITIONS SHOWN FOR REFERENCE 0I'l...Y. ACTUAL POSITIONS CONTRCLLEO BY PROCEDURES. 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE !'DTED.

3. SO POINT VALLES FOR RELIEF VALVES ARE NOMINAL Af'.I) FOR REFERENC:E 0t>Ly.

ACTUAL DATA CONTRa..LEO BY GMS2.

4. c:::::::=J -

BASEBOARD t-EATER I t3-REOO) (AH-C-42A THRU HI

5. P-WALL INSERT HEATER (12-REOO)

(AH-C-43A THRU Ll. I-c 400 CFM 200 CFM 200 CFM 200 CFM 600 CFM 200 CFM 200 CFM 200 CFM I-h ~I ,2 "I:i ~.-- hu 8 I ~I ii ~I B A (,j C~ FILE, VIE.846.21. 1000,001-.0201 0 THIS IS A CGF'UTER GENERATED DWG. DC NOT REVISE IT HANJALLY ~ (l? ~ -0 ~ S.S.BOLEK 30m 0iI!J Nuclearl GAl I~~'"";;-'-j*7\\\\;- D~iW-T~IBUILDI~ SERVICE VENTILATl(}lt- ~~~Hb_¢.D_"fJ.E FLOW DIAGRAM IA DATE PROCESSDG CENTER AIR FLOW COM?ONENT,,*srsIO I"ax--- ENGItEER-DATE 2 SYMBOLS INSTRUto£NT....TICfIl f'oIANAGER APPROVAL CATE 302-849 SYI4B(l..S FLOW DIAGRAM NONE TIlLE ENG.~CH. R£FEll£Nl>:S J 7 6 5 4 3 2 1

I j' I IE I B I L 8 8 3/8" NCT HC-V2E HC-F-1 AIR I-O(><)O-l£F"'--I DRYER HC-V2C AH-Q-1 HC-V2D 3/8" NCT Q Z 3/8" NPS PI-2 HC-V2A 3/8" NCT HC-V3F 3/8" NCT 3/8" NPS PI-5 HC-V3A y HC-V3E HC-V3D 7 He-V2I 3/8" NCT HC-F-2 HC-F-3 HC-V2G HC-V2H HC-V3I 3/8" NCT HC-F-5 HC-F-6 HC-V3G HC-V3H 7 1/8 H NCT HC-V3K 1/8" NCT HC-V3J DRAIN DRAIN TO TO FLOOR FLOOR 6 '5..,3/8" NPS HC-V2R 3/8" NCT 6 HC-V2P "8 SYSTEM" SUPPLY TO CONT. RM. H&V PANEL HC-V3P 3/8" NCT 5 3/8" NCT HC-V2L HC-V20 PS 687 HC-V30 3/8" NCT HC-V3L 3/8" NCT SUPPLY TO ELEV. 338 SUPPLY TO ELEV. 322 HC-V5 He-V6 3/8" NCT 3/8" NCT 3/8" NCT HC-V4 SUPPLY TO ELEV. 355 3/8~ NCT 3/8" NCT DRAIN TO FLOOR 4 AH-E*-18A AH-E-19A 3 057-47-5111 057-47-5IV 057-47-51 AH-E-18B 057-47-511 057-47-5111 057-47-5IV 057-47-51 AH-E-19B OS7-47-511 057-47-5111 OS7-47-5IV 057-47-51 057-47-511 057-47-5111 057-47-SIV 057-47-51 057-47-511 057-47-5111 057-47-SIV 057-47-51 057-47-511 057-47-5111 OS7-47-SIV 2 8 VARIES REVISED TO COMPLETE THE INCORPORATION OF ECR-O~.::..?0909 REV. 0 AH-E-21 AH-E-26 AH-E-20A AND AH-E-20B AH-E-93A AND AH-E-938 AH-E-94A AND AH-E-94B AH-C-7C THRU AH-C-7E AH-C-8A THRU AH-C-SO AH-C-SA THRU AH-C-9C AH-C-10A THRU AH-C-10B AH-E-95A 057-47-26 AH-E-958 057-47-26 057-47-6 057-47-8 057-47-7 057-47-25 057-47-25 057-47-6 057-47-6 057-47-6 057-41-6 057-47-6 057-47-5! 057-47-511 057-47-5111 OS7-47-SIV AH-C-5AA 057-47-51 AH-C-5A8 ASSOCIATED CONTROL DEVlCES 057-47-511 057-47-5111 057-47-SIV 057-47-51 057-47-511 057-47-51!1 057-47-5IV N/A AH-C-56A AH-C-SBB 057-47-51 057-47-511 057-47-5111 057-47-5IV 057-47-51 057 511 057-47-5111 057-47-SIV N/A NOTE: THIS BRANCH CONNECTlON FOR INTERMEDIATE BLDG 322 CONFIGURATION ONLY

1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY ACTUAL POSITIONS CONTROLLE.D BY PROCEDURES
2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DES!GNATOR UNLESS OTHERWlSE NOTED
3. ALL SYSTEMS ARE CLASS S-III UNLESS OTHERWISE INDICATED COMPONENT IDENTiFICATION SCHEDULE Vl0A 1I10B V10C V10D Vl0E V10F V10G V10H V1DI V10J V10K F8 VllA Vl1B V11C V11D V11E Vl1F Vl1G V111 V11J Vl1K F9 11 V12A V12B V12C V12D V12E V12F V12G V12H V121 V12J V17K FlO 13

~!- V]3B V13C V13D V13E V13F V13G V13H V131 V13J V13K F11 15 V15A V15B V15C V15D V15E V15F V15G V15H V151 V1SJ V15K F13 19 V16A V16B V16C V16D V16E V16F V16G V16H V161 V16J V16K F14 21 V17A V17B V17E V17F V17G V17H V171 V17J V17K F15 23 V18A V18B V18C V19A V198 V19C V18E V18F V18G V18H V181 V18J V18K F16 25 V19F V19G V19H V191 F17 27 V20A V20B V20F V20G V20H V201.1.12_9 120~ F18 29 V21G V211 F19 31 V22G V221 F20 33 5 4 SERVICE TO BLDG. EL. 10 AH E 31,33,35 SERVo BLDG. 321 16 AH E 51,52 20 22 IAH-E-8A/B, 24 26 IAH- 'iB 28 30 32 34 IAHe /B D,15A/B NORTH HTR. BAY 322 INT. PMP. HSf. 308 AUX. BLDG. 281 AUX. BLDG. 30S I:-.JTER. BLDG. 295 GEN. BLDG. 295 DIE; GEN BLDG 295 INTER. BLDG. 322 INTER. BLDG. 30::. 302-003 I 302-002 3 COMPONENT & SYS. ID INDEX SYMBOLS INST~UMC:NTATION SYMBOLS FL_O_W---.ill6Q~!A 2 H G E D c

8 7 6 5 4 3 H H G G =1 SECO~ rLOQR SOUl H F I~I;O CHi t 4MO CFM ~ I F"f1 I C! j-o..o,- 1000 CFN AH-E-~ I Cil AH-C-2M 1//////// ........... 1 1!5?O CFM 1 1040 CF'"

  • I GW-E-IB Me UNl r GW-E-IA Me UNIT

-2000 CFM 2280CFM AH-FD-72 AH-C-66A1B I.; 1......- DA~~~~[E~~ ~H-FD-73 LI ~ GW-E-IC "i,.V Ale UNIT 'I (i(\\ ~ = COMPUTER ROOM crm COMPurER ROOM QFrrCF F CAL IBRAnON/INSTR. AND f-IRST FLOOR ARC A 860 CF'" ~260 CF"M '%1 I E AH-C-64A/C HEATER! DAMPER UNIT E D \\ -, } lJ I [YI' I!" I 0 i ~ I\\) IJ, 01 I VALVE POSlrrONS SHOWN FOR

REFERENCE:

. ONLY. ACTUAl pos I rIONS CONTROLLED BY PROCt:.DURES. ? ALL IN$TRUI'£Nl 1AG NUMBERS ARE PRFFIXED BY SYSTFM DESIGNATOR UNLESS OTH[RWISE NOTED. 3. SU POINT VALUES FOR RELIEI-VALVFS ARE NOMINAL fiND rOR RcrERt:.NC[ ONLY. AcrUAI DATA CONTROl_LED BY GMS2. NOTES C:.-.O IlLE, VIE.846.2l.1001.00I-.05:)l THIS IS'-' COMpufm GWEIlMFQ OIo'G. DO NOI REvIse IT M'-"II.J-'llY I 0.1.. NORIH 51 AIRW[ll [A5T STAIRWELL D.S.F. Rom (STAIRWELL PRESSURILATTON FANS) AH-E-159 1127 1119 '" ;I I AH-C-65 7JOCFM = BA rrERY ROOM 100 crM FROM C.F". ROOM 0" 0G 0,_ oc," . ~JZl.r ,c !t @}- e\\-'i~ "" 0 / Lt~ ~""'"."'0 crM ~ ., '-2'3 AH-E.-148-L AIR"~ e FC _.NG UNIT _3 ..or:n'1-4; 5660. C_'M__.,-_~ ~_ ",-0-"" ~---, r= SECOND ~ LoaR NOR 1H .\\""l-f.'- Joy;? ATR HANDLING UI\\;i1 1/ ~ ~)" '000 CFM ~~m~.". I ..1 ~ .0.110-232 D B ~ c t I - ~

~,6 ~

l~~ A 8 7 6 5 4 3 2 A RLV. 5 _I

8 7 6 5 4 3 2 REVISICNS RE.V'IZOf£ IREVISED PER AtJ4INISTRATIVED£==::ORAllN IN CADAM HI IH r--------y TOD.S.F. AH-E-152 I r TATe ea-rrROL P-'/IEL G 2010 CFM 2010 CFM G E D F I. VALVE POSITIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEOl.RES. 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTt-ERWlSE NOTED. NOTES AH-C-70 LtlIT HEATER AH-O-276 --~

1
0 II I

I I 0.'. AH-F-I!! WELL HOUSE II <"!~ AH-C-69 ~LtlIT HEATER FC r------------r;;;; II AH-F-I!!8 I I1----- I I I I ~ ~ TECHNICAL SUPPORT CENTER AH-FO-71 FIRE DAMPER AH-fD-70 FIRE DAMPER AH-C-60 AH-D-256 FC ~z ~ ~ 600 OF" AH-O-261 ~ ~7 AH-E-I!!7 AH-O-2..a FC ~ TE"... FE-I 122 AIR FLOW STATIc... FO PO AH-O-245 2010 CFH AH-E-146 AIR HANDLING UNIT NO 4 PO AH-O-24I Fe

0) ;',< I " /

AH-D-2'6 ,-------{( 1':'9")-----, FO 2010 CfM TE "06 AH-C-!!9 HI F E D PRESSURIZAZTION AIR TRANSFERED TO FIRST FLOOR CORRIDORS 870 CFM ~I c Nuclearl GAl HTG VENT &AIR COND FLOW DIAGRAM IA OPERATIONS SUPPORT FACILITY IDEI ~~jT I I 302-852

SCALE, NClt£ c.I CAD FIL.E, "'I£.eI6.21.I002.ool-.0101 0

THIS IS A COMPUTER GEtERATEO CWG. DO NOT REVISE IT HANJAL.L.Y ')' Ql 01 II.l ENG.tCH. MANAGER AP~O"'AL 'EI'.GItEER 2 1 TITL.E REFEREI'CES CO/4'OIENT L SYS ID Ir-LlEX SYM8Q..S INSTRUJoENTATION SYJoeI:t..S FL.OW DIAGRAM 302-003 302-002 302=OOi" 3 PO .....-O-2!5~ / / )( I I I;;;1 I / PO)//I// 4 AH-O-2!50 870 CFH AH-C-61 LtlITHTR 5 IOOCFM TO BATTERY ROOM [@] ELECTRICAL EOUIPt-ENl ROOM 6 AH-E-14!! AH-D-244 AH-D-24J 7200 CfM 7 r-- I I I I"- - I I I I I I I I I I '-../ '-../ TC I 108" I I ~ -1. __ AH-F-17 7300 CFI4 O.A. c ~ I" I Ii ~I IA ~~ Ii ~n*, im 8

G 8 7 6 5 4 3 2 0-5 REVISED TO INCORPORATE ECR-1J8--.0Q53S fl[V. O. ~~ "/L! S V! s S 1 S S S 'J; ~59F ~ t OIESELEXHAIJSTTOATMOSPHERE 5591 SEE 8&R owe. 2038 H 8 DIESELCOHTROL PANELROCiM ZONEl4BTO PANEL 1717 ~ FS-IO-404 rS-IO-405 AH C 11~ ~AIRSUPPLY ~, F.. '"' ~I '<000'" I ~ ~--~ ZONE14BTO ~~~I~L_t~r r ~III-ON"'"" FROM TS5593 _... __ -, lJO.J;~ CFM §]- --- ZONE14ATO ~~ri}-~~? DIESEL OIL STORAGE ROOM 7 50'CFM 40CFM ~1~1<6~ -"i--~-~-~ I ~~~ ~! I IAH-E: I I§-- _L ~ -=-§J~_~_700Z0NE 148 TO PANEL #717 f-- I ~ 450Cf"M 8- .J I I c:::-.... ~ ~ AH-E-518 t ~~ ~ ~ ~~ ~-" 5583 KHS 5583 ..... _L __ ~ __..l __ ZClr'E14-ATO PANc"//717 I I ~ ~ ~ 6 I L ________ _ I I L.. ~!t~rR 5 I~ --~ -~ 1200CA.lVlA STAIRWUl \\J2!:j AH-C-116B A1RSUP?LY T - ~ FLOOREL. 305'-0. §- - - - ~~~2~~1 ~~~f}-r;2~98 ~---, -~~---T--~--~-----~ AH-E-199 ~~~ 1/4"00: ~ \\::V \\e7.-------- ~ ~H-C-l16A 1200 CfM VfA STAIRWELL ~!'I~~~~9 T~H~eN~Jl~~78 4 302-01Xl 302-001 3 1/2 OF ~AVlTY DAMPER BlANKED VENTlLAllON VENl1LA1l0NAIR "!i\\>ggoCF~ 7S0CFM COMPONENT &: SYS ID INDEX S'rIdBOLSINSTRUM[NTAllON SYMElOLS FLOW DIAGRAM ---.--~.,,-,.'-,- -~<-.. -~-~--~-. .,,---~---~---" -~ -------_.,-~~-.- ----.-~------ HOOD WITH ElIRD5rnEEN HOOD'MTtI 81RDSCREEN 61920 CfM 9160CFM* NOTES

1. VALVE POSI1]ONS SHOIffl'.J FOR REFERENCE ONLY.

ACTUAL POSITIONS DETERMINED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHER\\I;1SE NOTED.

G E !l c z N~B::-LA~C~K~OU~T"=D::::IE:::SE::-L-::G:::EN::::E::-RA:-::TO:::R:i ~:!'B\\:""-'~iHSTATIO FLOW DIAGRAM HEATING & VENTILATION FOR EG-Y-4 ID~ ~~2M881 I Nlltr; SCAI£: NONE 2

(b) (5)

(b) (5)

(b) (5)

(b) (5)

17 I 16 I 15 I 14 I 13 12 11 I 10 I I I I 4 142.1-~~a 3 2'12. I I ~-M:-~- I ~=r--1FrEL4:::"".-7 ~;I-' - -.-~:-'--".- ...------ 9-.~ D H G A I-- I-- I-- I-- I-- I-- I-- "*1J I CONSTRUCTION r-,(8~~ 1-\\~~~'ELSOt'J* A.NC\\-\\OR~ (2,'1 "ROWS 'OF Z. @l'~n SE.C"nol-.l \\~ \\ ~~.. ,::~~ '0')(p8'-"i" TO t I2..B. --c 'f/R'34~'r Sfcn*t -$IIP.:34@'~SCCTZ'*t


f\\~;~:~r;ig::.~,

DE T A I L 'A' P~~~:~~~A~~~~;~~~O~N~;R~~~~N J BIDDING PURPOSES ONLY DATE RELEASED FOR ENOR. SECT!OIJz*z AS IJOTED


.*. '*'*Z*Of'f'fJiWD 1l METROPOLITAN EDISON I::OMPANY THREE IIll~ 1SLANO NUCLEAR STATION UNI T 1 REAC10RBUILOING-CON04l{TE

~~~~~~~;:jK ~" ~~ ~~ ~~ c4""'39(4@'\\Z E.A S\\O(')F"OR\\O'~IO:: 'SLn:VE5 <l,j \\b "8-.,-::(4&12 EA. SID'C.)fO>2 "2.1.>"'li.y,;*5LE.~V~~I_ ~~ B ~.~ I I ~: tC£1t--+- ~~_


l-

~-.... I 1 I 20-""'4*-~9"EA.S\\OC)lOr;;, 11.;*1020"'5L't.EVl' ~~~:~..;:~~~~.~,~~~~:~.:~~~~~~; I c _,I I ~I" ("'8"30"o'~lzf l~j(ir{'i.~~;;If:t;}:**a' NlITES: I. fORCOIlCRETE OUTlIIIE. MOTES & REfEREIICES SEE lIRAIIN6 E421-030. ~I i~~! ~ ! 7f'....,~

i;~~

h~~; ~~~ ~ k ~",on"'oollLl.',.', I ~~

1 il II
~

II II ~eo' I i~ ,,~ ~~ I h='~" ~~ ~ ~'? ~ ~., : ~:: ~ ~:; ~ U: l8l1TT~ I 4 I I 6 I -il ,Bur7RESS"2 I l ~I ~§ <t HORI"Z.ONT.....L TENDON EI-.lO~ eo' I 10 TO?OF'CONC.....'e.\\~ E'-_27e'-1l1J I 11 it! I 12 \\400----..o..:..<tBUT1'RE5~*~ ~ I 13 'lHOR:I'Z.ONTAL T'E.NDCN ENOS I 14 I Sr5- "8*.JO'O*~/.2~' 15 I 16 I ~I I i It. HORI<:ONT~LTE.NDON EN05 UJO'-------' BU77ECSS"4 ~ ~I ~ ~I 17 ~'J ~' ~t '!I ,,:9 ~,I E I EL.3~~:J I 1'1 "C' "II I I I 'I' c-II I I I, I Foe ADOmOI<JA, e£WFaeC£U':'T 8CTWUI<J ".'.'! ~ I' "",p'o1ijJ-+-1i L.-J---J,-----I I' 1330 SEE sun N F N au [)We. <*4NO" ,. AXW'O I ]1 1 ,1 I - I I !I c'4"~0'~ I, I ,,~,~. ".,Lo.ow/' I

8*"8*38'0',/,,'

I;r-"If'lJi*IJ010.II*lh--.-

S**8* 38'0*./'V.

l' 1"'30'00/1" 58*'8*38'0-0/'" -- I N. I rr I II I NL,-_ I I EL....**~ ELA'*** I'I, ELAI.**.*.-! I I I llU II ,-moo-" oo! I 1 I ,*,,~o-~I ~ I I if 2*'4""0* I I I I I II I I II' 1.11 I I CLAOO**0*7 1 I ~I ~;['lJrll~ t--------58.830,0**,2,.-----II'~-'I~-~~"d> - -',I .j I ['~ II ~ 1 I ~ ~~ I cL.,** o*frl I I, I EL 389 o~ I ; ~ II' I ~. ~~ J ,""'0 o* T, II ~ Lid.,,r I ~I~ 1'1' ttt-111 . I' ~ ~ ',!fr.

  • 1**. SY"'H'~*

I e----- ~ ~ D 1""4x3OO' II ~'" I I I~. ~,"",'."",,,.,' ""","8,

  • "'4x3O'.0*A -r-----

1,1, I I -.. \\.j -..ilf~":~*(o)'*. II:~$O!O~I 10"1 Iffl ~~ 1~_/j_~AJAMJ-'t)lI/l~ ~~ ~~. I /J*~/O()!O'i>II"' I !I 1111 I I I 0.2010 0241 ~"S .;. R ":::i E.L.3--'2.*-fi::t~ .~ ~ 'I Q" ',,*n,",,* I ' II I <i:.i.... I ~I ~.' -f'/I'I""~" I I '1 ~- W8-!O~ *.,,,.J: I !I', I I~- JJ .. ~ ~..,'"-..-----~ ~.,I I~I,'-'-.__.__ ""'$0*0'12,* I i~T I .~ ~ I I I ce.'",..... tJ,- I' ~~ ~I I 1.:":'.:, ce'.'**.* ~i I rU: ""4'30"0' I I sc.CTl.OJJ 3*3 -1h z.".a,.x 30"0 I I '-'"4X,""" I I Ii I I ~':" ","0',/1' II~"''H'JO'O"':'.., ~syH30'O"'I'\\ 1 I I II I II~ I' I I II Itt I II I '--- ~,.34S0*"7 II I I I Ii B G c I II': Jr--i--,..~-;---'-'T -I ~ III 10" &-4"~JJ."':6'6~~ 11,0" /8'-8'3()!O'~!21" III I IIi I 2.II,~ 58'..,0'0'",,- II I ~o 7"..,Ir**'1;H= ",.'",,,,,.~,. ~ lml s I!Lr-- - 58**.*30'0*""* tw 1'1 1", I~ /" I I 19" nl r- ~ Q! Q! [' a. I I ~~ O"ZJUO-237E 0"238£ O'U1}£ <Il ~ ~ .~ 5,' I /l" ,z" 12" '2" "IZ" ~ "~ 0 0 I I '9 ,I )of ~.'II .J+-.. O'U8£,E<S~"O'7,o.m E O""OE 0,,1£ 0.",. 0."" 0.,,,, '0- ~I']1 ~~L L~~ II I 91~ "l. '0' ~.. 0" t- !,J !,J , <L EL.3"'*..1 I I' l-il........- ~I,; V* I. nT 'T 1H1 I" I, - [J..'34*" I I I ,I! ~:; t

j I~~W~

~ I ""-'.80'0'.,1' I Ii, I o:,~;" 0"" 0'"' 0"'"221. ~ 12" It" [ h*--J""4'~*O' l rr-''-i '**..30*0*-<:-!- 'I 1""lo,i""o"//' I &.~ 'm,,, 'm' 'UAE :r@ ,~0'225£ O,,,.u I,f '.'... 1" ,1 I II' 2"**,0' .. '_I 'I """'JOO'll I '0 +-1 2.-"12."K£.Y CIO. 'E.'?E:D Ol-J ",'*(,,'WA.U-I [' I I "','1)( 12_ IZ_r _' I ii' ~~" <I; O'2/9E O'220E 1 II --j- .~,. J ~ b 1 1: £.1:..,,,',1.:.,,,, I ~ ~r:: J lI--::::::c_ ~.t; '.,l III i 'I 0.<)',1"0"" 0'<)*' rl"~'O' .<)., K)" 1 ~ 3 4 ' 1 " H ,~5i IT¢:-- /' I 17!4 ..::::::::~ ,r# It'll"' . I! I I ~_~......../Ot.-"'ItJ7. EL311*" 7 ~~9 o;t:'~'11 'I '0 0" "II ~,," 1-1" '~;"O O*"o-l~O*l~S ~ ~I' i I U I I I'~' ,"",pi iPEIJ£7£....207,-. 2.13 "'~~'2. "Z12 2'f i Ii==~1 I El:,313:0~-" + I 10 olroJr all" ~; I I ii

  • I

""I,;' ~~, " \\J}""",,'"' -- -,,"III j. Cc.=< 0;;; I HI.r......

1

&1..

  • ~Z.1OI£

~ .~:: j, Jllr... II ~- 58.8P*O.",_ -- I" ~:r"'~t'" I i:~!. ~ CL.':>.",,_,n l~ \\0X30-Q'"GlI\\ I EL 30~'-1o*./ ~::' OMG 1"/ 1'0. J:. .JV'" I ' : O ! '!il ~ jot~ 13' 10'~ 011 ~.I'-- 1 b-1/ I su TYP.[)£T.A*FO~REIIJf, I _-.=::::::::::::: 124-30-0 AROi.INDPENer£SUl'JIlS- .....-:::t v I: ~... 1(: --l I ~ ~I ' I 0"*' Q"'~' 0;'" 0':" '*"A'30*",-=,t:::1 .\\ ~ 'I ~~ .\\.~))~~ .~

  • r

~ ~I I '31"3E 3~E---+:=~(HF 2tJS£ 20~E N t!!o ~I::l

}~

~~ ~ N 2.-"4'(30'-0' ~ ~ I I " ' : : @. i. ~- II> EL.295!(,'? 'It t:.

== t@) <fl if IZ" . 12"'" 12" /r 12"" i. Si ~- ~ ~ t; ~, ,~ 0"3\\1~ Q31 2.e. a;a£ o:,./102EO"/103 ECS ~I ~~~~. LG-.40 U ro""'I:" ~ til .~ I~ 2~fCl(7yP') ~l % - I. ~~:~~ ~ ~L.Z~*.C"---. --ll-e

-7f

~l-. _....t-~ N' 2 ~ '~~'- ~ I-..i- ~;,,, ~~. ~ \\.. "I'"

,.~,

~ H~*- n H;' I f--. 0 1 ~. in~. ~ ~ ~ 1L~ t--- ~ ~

,~

4-- ~ in ~~ Ii;" -~ <l,j t ~ ,.."PSPaet(",) ~ I

11 ~I I~I

~ ~ nT j" ~ ~'I'~ I I r~ lTlJ-----iQ

, ~

~ [""AT I ~ ~ f;

17 I 16 I 15 I 14 I 13 12 11 I 10 I I I I I 4 I ~~ 4-d--riF' k43~'07 ~+- ~--.- =4-I ,,-r EL,4.""o'-" I II ---j A J--IIItt::> Z.*-4"-'l.C1*<::£ fL 345;0'2 \\ '~I £1. 341'.~_ -L-'-'f+-:ttl A f-- D c B f-- f-- f-- f-- HAND) 2-2 SE:cTJON SteT/ON 3'3 StCT/ON 3 -3 (OPP. oj INTERMEDIAT£ -LAYERS fl. 297~:o-'-*.--r-~--+i:lhl-c-c-:-i .~ E'l. 2'=r3:4-'-L.....__~ [,I ~I ~l~ ~;~ II 1I I I"i III~ '. ~~ I III ~I'II ~ I II i1f~t, .,.,28'3'.9(007$'D' FAC~ IIII 'II ,£L 3.70 I I I I, -EL>.~. 'I-"L'/O 300'1/'i I ~ +.. "Sf>9"" +- ,S, '/0* SO'O',,' ,I ~",."...' I 5B"~o~,f - ---III I ~lt -~ ~ -.-~--


l I-i I

I I I ~~ ~ ~'" ~ r

Z-/I,c3,oe,8 ~

l--+ I ~; g~

~'"'~

~£A--:lNITRT'rlcDIAT£ LAYEP. I ... ~~i't -~~.... I

  • 2....4:o;2ld*0

~' ~ ~~~

tl~,~~

~ i ~ T ,~...~ ,~"~~ '-.EC.050*(" 2-"4"30"O"~ ~ (J <J.- I I I ~ 7<i:',,d.d',,:"::;"S,O, FAC£)!


_..---I 11 l-----~_4 i

.-=-El... >AS"O II I r-vr-r..r-,..,,, ",.....~,~.. c.... ~ ~-8-'.a':JO!01l1dR* r EL..345"O* 68*...8*J()!O*~/2#* ~-+- I 1111

1;

/g'~0'3O'°1 i:C-EL.41c..'.,,*] zr~ LL3(.,1'-~*) 2~~A'" ?,o**C*, -II

' ~

ill i; ~~ f-1"'~,. 2"4<",'o-4--_L~t "--jH I' i III" 11 7 --= I II II I ELA'.'.') I '-ELA'.'.* I ,lr-'*'~"d ~-----, S8*'8,,6'<N/2" ---j dn~I I "*MO,., II **~"l: I!' I


t I~

II j 2,'4'30'0" ~ I -2*:4Ji~C5'.:o~~ V-- 24X30'-O"--4 I I l!.-- EL.400'-O* I'

  • : I

~l II I1 II I I ~I I I ~~ II-j I I EL.3l!!8*.0'~l-t J$-~,fJ.$()!o'6'111 I I 1$,'IO.jt)!()""II'. C~.L.;'89**O* 58**~*JO~O*(Jlt'/ I ,.,~ I-- -1 L I .~~ I "'-'11 ~i IIr' ...."'.~ II

11"'-111 I

11,11 ~illl ,-"un,' ,III

11111,

~,~ -"r EL.389:7 D c f-- G G f-- H It" a"jlSE 0 12'" -JIM IE"' a ".1/1£ Ir' 9p8! OI2'~ dr-dr'dE"c/ o

  • dZ"'

'J19£S '"J!()S'.Ji1 "'.!2Z"J2.!S T#S IF i I, I: NllHS:

1. FORCONCIlETEDUTLINL NOTES, RIFEREIICES SEE ORAIIN&E-421-030.

H f-- 6a*-a-,JO'O"f'lL'i' -,--III ~ CONSTRUCTION P~~~~~~~A~~~;~~~O~~NAS~R~~~~gN J BIDDING PURPOSES ONLY DATE RELEASED fOR ENGR IIETROPOllTAN EDISON CDMPANY K 17 I 16 I 15 _,,_ L_. 14 I 13 I 12 I 11 I 10 I I 8 I I I I 4 3 I I

(b) (5)

17 I 16 I 15 14 I 13 I 12 11 I 10 I t 9 I I I I 4 c 0' B A f-I-- I-- I 2: - 2 115.,,' 1,-'., 2:0" I 2:0" 4:b" I T<ll~!o' SECTION l:o.Q-'./c I ' I 31~1<>* EL Z~ql':'-oc:'J.~L~:::""':hL':'!;I==::t:::t--=~~~~., I,. 'I ';,';1... 16-*'e~.V£.11111e.*(4-'*'n',<:,OJJ 1.e*"JB-~,YlJ>r {1:~*P'.l:O.1lHli:..'"

14;1( /.L*ot

'N'-II"" .~ 1 I 4;'0' Te-*le~.. LO'*O~Ie.-ls:o*r~oJ.t I I --1 ~ I I

il gL I
PLAW, DOW'-l-5 ;:Of. W~~T WAlL 01=- A.ux. t:oLDG;,

?Q~ 1:>'-11 L!'> 3-3 g 'l'r7~ SECTION I~I 4@.'O' I I,.,,' J ~s' C9 ,-=it r 31 1 111

{

N -e::I $ ECI

v<~

~'"' 1 I A5 'HOI,IN, 1 l 'I _:! I Ii ~C"*." ***J' IT i t==:t+~~ I q*;/B.Gd*o"eIS* 4q:ra 60-0@ Sl~ I" 1 I~ I ' u.~***"

  • .*.~,...,

, ***.~*'... I,.*.***". '~I:~I I I ~k ~r<J' ~~j Ir* )~ J £1 ,r("~""" 1********",.11 ~'ON ',~,.,.,., l1... J -0 I ,,-1 -'1 If ~ ~.- ~ ~~ 5 EG , ION I - I (S'MOLARI '~~ 1 1 ! LJ 'ill L 1 "B'OOW"m:N , I I: I'EHL'"I I +4-+- -l- ,uo ' ~B"Z\\ I' 5 0' -h II S 0 ~I I I liL t -"'" (sr' PLAN) ~~I<.~~Jb'. -=TI~ 1 '~11 rl~:J~ Ii !I'~I~ it-- ,: L ':['.~':' II-lt::,,1, "0, STAGGfR BARS "~I 1+11 rr--~J:T ---l!---. I IJ a ~ AS Sl-/OWN I I 1 II --I 5 ~

/ / / / '

fi "" ~"6 I: '~~I/ ~~- T==t-- 1J b\\i~ ':5 60-,;" V<t WALL BELOW )... ,60.~-" ~ PLAN OF BOTTOM ~L~;NFORCE'ME'NT ---+'-:'J@ r 11-r~ II 1 I r rI ~~ fOR CONTINUATiON OF ,rrn l:~

i I r rr i~ ~~<'~~ 5 SLAS
';~
;2~~::OIB N

,,:,""'-:;;f'.~ =1 rn 1 a I

k__

'0 ,-r

9

-+ ~ JI-2f sf ~_I ,7# f4:... ~ K-:.J (I- .~ _J11".1' 7* 2£ 2I ~ .2 f."-- L 1 I G-IBdo'-O*t!!ze* I 24*~18v'1o'-d.. II' l~ I 1fq*-)8.3d*o"el4r I 6*.../8v301o'<::>ez** i:]; I. ...*18>3C1-~j ~-IBdO~o"E..!.1.~,1~ I 2:<1-"'18... 30'*0" Oil II' It b-"18~30"O'~z I

-~~

-~ G H I-- I-- K.A. ENGR RELEASEO FOR CONSTRUCTION I P~~:~~~~A~~:~;~~~O~~N~~R~~~~gN I J BIODING PURPOSES ONLY OATE 5'21-5, RErllftlRl:(UHTllST HOTES;- I. COIICREH TO HlVE A.IHIJl.UIl ~0Jl.PHSS1H srREHGTIl Of ~OOO P.S,1 AT THE EIIOOf,a PATS.

2. II! REIHL tAU SHAll n

G~IOE 50 Ul. III OTHER REIHL BARS SH~lL HI: GR_OE ~o ~Sl 3. AllCHORSTUCSIHERE IHOICATECON DRlflHS SHill BE J/e'-,IlHSOIlCOlICRfTf AII~HORS ! 1116" LOH~ OR EQUAL ~. UlIlSlll1lH TO BE CUT FRO. WoO' (p*nSS) LEI/GTIIS AIlD 10'-0' (P'JJ1O) lEIIGlHSAIIOTOB£fURIIISH£OIlTHEIIOCAPS(P-3JM) S. UlIlSTRUts SH.lJ.l Bt LOCATED III e(ILllll1S Of AltAS AS INOlcmo 011 O'G, Kf (5'" fRDJl. UltS AHO AT.'*0' e.C. G. fOR u,mOfO PlPINS AIIO COHDUITS SH PIPING 1H1l'ElHTRm~ ORI'II/H, ) UTERSTOPS TO BE S' "SEAL-TIGHT" PVC THE NO.BJlfi B_ fOR, AOOlTlOtUl PL.IJ<S. setTIOIiS L DETAilS SEt ORHIIIG E*m*O~1 IHtREIICES:' S*(H-UD Is*-o'(np., ~ rt--j ~ 1 e I '0 ~ .~ I "I IS:dlTYP.) r i:~ II ':~ 'II 'I'~TI 1 1 1 1 III'~ 111~iJ ,LlLjJ_.l!~_ II I 31111 II) IJ ,'e1' -~" fl'{- ':2" II'" l.... 8"8.Gd-<ie~' -"'8'~O-o'~i~ I- ~r,'*IS."o',oeze' &.60'-0'.1<" C4-'18'~~ 7**'B."d*o'.zi I ~ II II, {! =. I L ~ 1 '~ 1 i _EI-",,4o'.O'tSZZ" I ,\\ I I ~

~

,~ ~ 31*... 11,.40~O*<!1 ez. 24-J la.w**Oelt "2 -t L.- IiI I! ~J' ~ i 7- ;s"",d-otZ: U' I I it~ 91 '9 rn H G REINF'ORCEMrNT ..L) ~~ 1'1 b* l, lal --1 ~~~~~~;;::IK UNIT 1'- I HEAr EXCHANGER VAULT ROOf SL,6.I3 ELEV. 305'-0" METROPOLI TAN EDl SON CO~PANY THREE WILE ISLAND NUI:LEAR STATION AUXILIARY BUILDlflG-CONCRE1E I 4 I l( I I 8 I .6.9 I 10 I ~~~~~ 11 I 12 I TOP OF 13 PLA N I 14 I 15 I 16 ~: 3'~O~ \\ I I 17

17 j 16 .... 1 15 I 14 I 13 12 11 10 t 9 6 4 HEAT EXCIUtlGER VAULT ROOF SUB [LEV. 305'-O~ A o THREE ~llE ISLMm NUCLEAR STATION UNiT 1 AUXiliARY BUILDING-CONCRETE H G c DATE I RELEASED FOR I(NGR. METROPOllTMI EDISON CO",PANY

n'~J LIMITED C~~;
  • :~~~I~I~:N AS NOTED I j(.A-PRElIMINARY NOT FOR CONSTRUCTION 81DDING PURPOSES ONLY I

.",~,.. ,~-" '" IK .,,~~,""'"..I..o.,,"-,........ ! 1._"_""...... I ilK""'" HIlUS:- 1 fOR NItTES AND UHlITIONH I'LANS AND SECiiONS SEE ORA11HC E*q~*03a. WEB REINE=:" BUNOLE '(TrPJ

'ILOR*18 ADJUST RElNF IN FJELD TO ClEAA A.NCHOR SnJD~,

(TYP.I 4 I1E SHEAR REINS:: TV THE NE'AREST BOTTOM <TOp R£INF. TYPICAL SECTION "I',li It DETAil*;;' ('6 e~:Z:4l-DETAIl'C' ~.(;TION 1*/ l".

~

1'-0* ---+J-"I-+--r- ~ PLACE ONE': aVNOL~CFi~vc.o BARS AT ALL lNrERSEc IONS-OF THE GRID. SE~ PLAN Fl NUMBER Of BARS PER BU,,!DLE.. I l.ARGE5T NUlo1BER. I /srGMENT tz__ BOUNDARIfS' PI A N 'A' TYPICAL PI AN 0E SEGMENTS I/:: e4',,'it.,. z'-o' 5 ~ Il 1 (II' /1/ f --.Ltt- 'o 1-IO--i~-;ll'-~o~/~~f~~~EJ3ON 1 ",I

===t=+= ' ~1-::::'1=-9--1--- ((~ "~.. I ~---'-_. - L 'l-L...~1- ------<r-~._.------e-----t---0-----. "._- ---.L-i "e;/"3,,1 i ~ DETAIL 'f' (ZII£OVIR[O) L!....----rr-i I 1:::1 --I \\...u 1/:0" 4*r~~o'-8:: NE\\.SON L.+__+__+_L~ CONe. ANCHORS---+--L-J ~,~,~ ~ r-:-- D '~ -:;;;r-r j I 5 __.. ~. "Ii( ,-::/'., 7'1,;,;{~.. I+~"~.-i.;- CON&' liNCh', -,.-i'. __~~ I Jl""'O"~ .' (/0 RlOUIRCO) DETAIL D D[TAll 'A" (42 REQUIRED) J2..U:~ Ii:. R"'VIRrp) <:.- SPACes ~ ~I". n:n' DETAIL

  • C*

(q "'aU'R'O) ~ q;,~~yd*ll~ DETAIL "6' It. 9",,1".. 0'*'1 DETAil J:l.' L3 5<G~rNT I BOUNDAR'" ___J .L....!...-. a~LJ 1_1_0_. .L_--...LL-...: (*"'- JI*,**** il I i l 'e tt=1 =p-CJ "-~*~,7~.::*NnsON~- I -: I


,-h-CONe. ANCHORS r

..J. e.-(.l I I""-.n',,;,-o'~ DETAIL "CO (/ Ii'CO/,/JRlO) ~ "'9 10 11 12 13 14 15 16 N -=::::::::r 0 -=::::::::r TjTI ,II ~ " I t I II ::, I I - t =r -~fl

1 3'~II'Y~O EACH 3-"lf*VL.O EACH I C,.-"II-VC.O EACH 1

3-"IH0 (.A,CH I 3-"'nv"o rACH It I: I 3*.... II*VC,O EACHI 3*-)I-VGO EACH I G*...II*V&O EAe/'! I 3 "UVGO EACH 3 "II VGO fACH I

1 BUNoer i

BUNOLE i BUNDer' BUNDLE aVNDLE 'I: fL*BUNDLE 'I BUNDLE I BUNDLE I BUNDl+E j-BUNDLE II ~~' ,I' i,w" '"" I,"",,""J",,","WC"I,W,."L,.,,",,,! *ino","C" I,,",+/-:+/-,",:,w, ",,,,j '01 '-f~ i 8U:~_=-tUN:LE I BU~Olf BUNoer Ii BUND+/-':0_"_1 8vN_0+/-r aUN~l_'_L~~~'_'_l

  • 0

~,. I --+- I' 1 [ o 'o.~ .'7 ~ I ~ I I

hll '" L"'"'"'" I,",w" _" ',".

W'".",1,'""" '"" I,,I,;,",. "'" '""""oW I,,,""'"'"'" "."w" I",.,,"0 ~ ~ ~ II' BUNDLE 8UND~lf SECYllON BUNDLE ~ ILL: [' BUNDLE I' BU"'Ol~E SfCTION' BUNDLE: 'BUNDLE

1

.~ ~ ~ I I" I I z ':' ~ I* t-, I I w \\PJ::;. I 1 ~I I ~_ 1, I


*-----*--*1--

~t I Sf[ PLAN A

I Ill.,>w 'wo I,',,",. 'w I''',~, I,',w""'"

II: III,_,=t,w,wo ,h,**oto 'Wo f BUNO+LE '. BUN+/-LE BUNDLE 'I BUNDLE... 'aUNDLE I':: I' BVNoLE 8UNOL'+' BUNDLE 'BUNDLE 'BUNDLE-t'l I i-('EGM[NT I I' I I M _BOUND~RI(S (TY~)

I M

I CONST. J1: I I i, 3",*VGO EACH 1 3.",vGO 'ACN ,'*-'Wc.oEACH 1 3.'rr.VGO EACH, 3:,WbO rACH ,i [d,~ co'"L.. w,,, "", '"'" I".,_.1=,w I: @I!'or.-'E-J_: ~ _W'__L::J _=~~__:*i-:'~:'--~__=_J~=~-+_~:~_'

~

I I ~I ~-I L!3*1 <0' ~_ 5-sr~MrNTS e 11-.0':05:.0'- =-1..,_ (~ PLAN OF ,sHEAR REIN FORCE M)J:lL. ~ 17 t:-<.' H / _.a,J2 j _ "G~ I ~J / ~ I I ~~'N::;~~R~N'~~g/Q I Or-- se:£ NOTES. '~ I; ~ I 'I su /)[rAJ< >'rOA CON,T JT. I If SIZ£ UNUSS ~ ,,_.~ 'l I II I 2<:'.'1" 23'-Il'


~~J ~=-=-

~ t',,"'","" ~ Ih' 7; <4* II' 24-'" PLAN-ANCH 26*3-OR PLAT E'5 eEL. c99: O' 24'*,,' G o H -i -~

/l 13 I

J,. 5 I' 6 I 7 I 8 I 9 I" '10 I II I 12 /l I 3 r___----L.-


,-I 2

A D 1° IB II ~B* I,'~ ~;olT Ho.!o.G; ('5T'2... 0OL,...,60 v..~) r-'Lt..-t-.i DOTTOt""1 PLA.TE:


j,. I<E-Q'o.

~~\\ 'I -- 4j4~:.' .j V:_J-I-77'(l-=:"~~~~71~~~, ". ,....--/~,


1--~;

-iD'- '" -.e--. ~ t6*2',';.J...-.lc....O~ IX>:"T~ (~r""QO\\.,""'" ......"') PLI>-I-J MIDOI*.E2 PLATE::. LQE:Q'o. ~ '1 '£/"', -m- ! ~I _I ~~==*J.j-'~:~' ~ ~--.. 'J. ..7;;~_..,... I ;_ CIl~,~ ~ 0/ '¥ II \\~'\\~ * . 4'0 ' ~~ 4',d:;!:,- I1z,oC; ST£[L~ SNUiFf !I'. (21-REGUlR£D) Pl.A.~J TO~TE: 2.-:<C=Q'D. (FO< LOCATIO/-..J ~I::F,' OW(~,P-*4i.I-oc(,.;J .i~- ')". 1';0",1" ,"OL~c; (":lr....... nOl.,'l"o A.'<\\~}

>1-
'- y!:..of3t:P STTFl.,'"

(C.-RU1JIRlD) ~ zsorMACIi SlJRFACE o -I -I E 0': F ~-- BIDDING PURPOSES DNLY I-I, u i.-- I f H i N~ CONSTRUCTION Ll~!~O CQNSl R~CTION: AS NOTED PREUMIN,A,RY NOT F'CR CONSTRUCTION DAlE I RE"I.F.ASEO FOR j ENGR. ~ ~ETROPD!...IU.tl EOISON [;DJ.I.PAN"Y HREE Y.t lE IS!.A.ND NUCI.F."R SfA. \\ ION IJtH'\\ I I ~ _. REJ.cTo:RBu*iLDi$----.---i-~ ~~ ",,\\ L ~-=--==. _.~SCELi.ANE~~~El. =_-_~=~ ~ ~ ~ ~ ~ --j. _.Ff.~~..§ENEn.lro~~J.s.L!_.!~~i!...A.S}~-l ~ ~ ~. ~ ~:~~l ~ ~.} ~ l *::'~':'.7_~'~:~:'~;~~\\O~~/~\\:.~~:::N~? Iy. D. ':;5"' :. "'~ ',*. ~ [,;:'-."-""":'" '".*....~;~"*I*,,*"".."-I .~ ~ ~;~ ~ ~ i;'t: ~ If2JlJ:r.:~~:;~::*;~*"~~~~~*~r..~~~; '-~-~~"".~ Il'*"'"4192 D-521-0171.1

,,<
1' 1c.:'. ~t ~J~ ~
.... J:.:~~~~.~EEf ;:"--=-,~.~;;;:<~~..

i I !

\\PfClflr.AIlOWS 1.

All STEEL Fllf: ANCIIOP. BOLTS )tW nATEs SH~U COlHORIi HI '!li'HIFICHrOH fOR STiiY.crUHl srHL'ASTlII13S-Mi. 2. Tllf CIAC\\lLl..~ JLH1 (fi' 12') IT (LOUlDN 219'*0' SHAll BE UlH,lSOKICULT IHS,lECTlD 10 INsua W,T TH:: ST£:l IS fREE fRC!!. CROSS nHEp.N,IJ. 01srn.'H1NUI1IES SLCH AS rms, IlUPlIlR[S 1.~'.l U~INmO!ls. THE 'ROCEOUP.E AHO ltCEPU.H~ lH.ND.l.hDS SKIJ.L H: 1M "CCOROAtlC; 'lilt

  • SUNOA~O ltWWO

"~D S?ECliIU!I:lH F(llt UlfR~ro'llt TBTlll1i'1ND It:SPHTI(W Of SHU flAilS Of fill:: 811~ AIIJ /ilrolt OUAlIll.' ASll1 ..l,~35-6~. jo!Dr.. s*

3. mos Sf'm aE M~DE ONLY BT "EleERS AIIO lEl~IIIG anUiURS 1110 KHE BHII pat-VIOIlSlY CJAl1flEO ay HS1~ H "MESCRIBEO BY nit IJURICAII -'UOlriG SOCIETY ror.

lIAHRIM.S Mil TYP'E or IELD1~G 10 BE AClDl'PlISHED.

4. mOIIltl: SHALL BE OOHE

).CC()~OIIl' 10 i~E bEST WO~ER.~ rRACTICE. sms Of '1ElOS ANCI GROOVIHG $lUlL SE 'S IHOIC.l(O n~ '"E ORuIIH:S. AU n\\OING SHilL CONfllltfil 10* TilE F:EQUlf.. g,juas OF I"f

  • STf.~'OA/lO t:OP~ fOl rElUIWG I~'

~lJlllll.'l" cDw.iTRUCTlO!j* OR 111[ 'SUhCI;RlJ VH:rrlCloTl\\lH fOR '£I.0IHG Hlljl(....T AIlI) llAlUQAIJ BRrDG~S' Dr ntEAIlE":JCAfr;JElDINSs:t;:I(TY. 5. SI Zl AHll COllrollR Of JelOS SMAll B~ IIUSlIIH.U )1111 Sui HilL!,..lC[S. .lll fR;lS S~IU ~~ lNiP[~TH! 61 lHE ~,l.()l~HC PUlllC~~ ~... rlllJ~ III t.CCOROAlICE IITil "SrJ,SDARD MErliOO rOR DRY paYOEA WAG~EfIC ~ARTlCAl Um/:CTIOH", mw EloV. L lElllS rOUND OEflCI[1I1 IN 01IUHSIDH aur NUl IN (Iutlll ur BE [HL.l.RS£O BY AOOITlriHIJ. mOING. UH' mo FOUrlC OEFtCI(NT 1N DU~L1tT SHALL 6E WIOHO BY <:IlIPP IN" OR IlEt TillS .l~O T~( llUO SIMLL or R(li,~OE. L lHUlER CIJALIFIC,l,110IlS AIID 1':El~ING PROCEDURES S~AU ElE SUal(lHEO 10* T": ClI:~Sl"iJC* TIOh' MAllm.:; rtlR mrout. C~DTlfIED ltllL nsr UI'ilRf5 ro" m UnRI..H I1SUI slim BE rUp.~'lSII[O Til tilE C)HSlIIUCllt!'i Ilr.NlGH flll:l!!R in H!RICUION, Rtl'DHS ro, llllf...TR'JOtlIC AliD IIA9IHIC 'ARTtC.l.l. iESiIh'(; SHAll Sf $1I811THO TO THE call'* STRU:TI[;N Uh'~G[R. B. All "MCIIOR ~OL' THi<UpS Slllll 8( a;'J I(D.1 Til C~EAS~ iHll 'ROTHTEO FR()1l. DAUGE. L InwA:..S AIID FJ.B~ICHIOIl SHALl 8E SUBJECT TO IIIS?(CTfOIl BT Til: OJNSHU~Tr(lH NAh'AW! 1N TKE Mill ol! SHil? IIH Cll>1SlRlIC1IUH lloUiAC~R SHALl lie ~lY[iI r~D rm:s NOTICt PRIOR TO !'ERJOli!llHC ~EClrien n~rs.

10. SHill' ORU1HG SHm Bl PREPlBHI r~R.au PARTS AIlU

~U~~ONEIIIS. ILt Sll;)P DlUrlHGS SHAlL 2E SUlllllm£D FO~ J.1'fi1lU.L II. ,l}PaoV,I,l Of HlIlIli PROClOURES "~O OI)~UFICATIO~S ~~ll INSPECTI\\lt.i SK~U HllT R(UHE mE Cl:lNl/l.l.CIOk or r!lS IIU.-OIIS1BIUll ;:01 'ELOING, (P.BfucmOK OR llJ.iERll,l ~. 12, 1l1h'I!lUl! ?IIfKEU 0:- JOO-f. IlUST BE K.l.INTJ.r~ED OJ81KG TilE _HeliN. OF Til;; ,fi"'-'--' STWI Ii:NEIIHOll S!=.lRT HAIIJf. TO THE SOU f'LAiL I h:\\ ~\\lHE At/CIlOl\\ itUli IIUB 511All 8E uo[aFINGEllrtGHT'~fl£R!iICfl rIET SHUL~';: \\.. ~ ..: GIHX", OHE HHf TURK INTC THE 'SlIiJG" CC'lOIHDK. ~---~.-' ---Il;-------T- ----.,,---.-.- I 28/-'0-SECTION Z-Z "c:'<:J.,.,\\ '" '~:f' "~ '"..., {-l'JO".l r g'" ",'no 7?J orvCiop /2£% OF tHE f~BflK:~ P='IJE:.T.'!t."TIQU '0~ O:::;E::'Cl"D~ I-I c::;.,e,t>JE:ll,A..'Tc:;.Q AIJCl-!Q:< ~'::OL"" ,,~ ~i::Q.UI'ir.. O "';;liAH /l:L. 2.75:'i~* EL. 21 lj:::;i' 1===,=, d.S -'",,,eco! '0 .~.. ~V: i?1'.. '" OO~T ("!.<:lE: 10; 7' --i I ole. ~C1l,.T':l*",q,~,c>I>"C~r::. ( DO NOT \\-./(\\..0 ~T ) CON** _~f'..._____ 0. C:AP i;,tT\\.,'U.... It 5.


p-v-..............g:

E:.L.2.61:<:::"...... .U'" " I I I . - -'-._----_._..._-------_.._---------_._-- --_.._~_._-_.._._--_._-------_..._-----_.-._------._. -- ----_...---.-.. I 2 I 3 i L. i 5 i ~: I ---II I I I.J Ii

(b) (5)

9 I I 10 8 H G D c B A

~

~IL T01028REAKER TRIP CIRCUIT GAi DWG 208-163 ~ ~ m{, ~8~ 4----"i5!_- m ~~~ ~~ 020 ~~~ 1~~ ~!; ~~~ ~~ EG-Y-1A\\ ARC-FU-7 PN(TI4) ~(TJ) [gj ENGINE READY TO LOAD IND. E£!::! ?B:h. fANTRIPCIRCUIT COLT IND. DWG TOCIRCULATJNG {- 01760240SHT.2 Aj" J 81' ~~ o'i' MANUAL VOLTAGE <fo:i'lr~LocR~ ~ ~~ ~~~~ lR~~J:?e:R iQQ:(l'l'R) ~ D~CES59X& 111XIN TD~Dli~kO~J!{f~a~N~l'MR IS UP TO SPEED AND VOLTAGE 91TF;c: 3ITF: TO AC FUEL OIL TRANSFER PUMP CIRCUIT SEE COLT IND. DWGS~~~~B41 ~

~""-

~ 0, o* TIO ~o~~ hlbl~h- <<uz

J::Jffi~

gg~~ ffi~~~ ~~~~ ~: r""' 71~9X2 759)(3 sl59X2 ~ = r= 1= T16 1 1 2T2J 59X1 59X1 59X3 A=8 T A-9 T A-C r 'i¥, f_,_~ !_,_~~ 1 T16 1 D 2 122 7 81X1 S 81X1 S 81X3 r=* 'f:=',T = -10{C2) TO DC FUEL OIL lRANSFERPUMPCIRCUIT. 1f~Cft!Je~~~1 SHT3A

-111 trs-10

,,~-' TAD-7 67 B6 D--t---<>------86 I TAD-6 I BS~BS ITAD-5 "n1-A I 64~64 Pl~ I TAD-8 TIL.C I Pl P2~P2 l TAD-9 I "!U-12(54) ~ ~ g

g

<m o SITT~g: ~g~~

i~M~

~~~i §~~~ ~J:-~ CD ~ ~ ~ ne<fro f"" f"" '-V---------'-- SPARE 81(Uf-2) B-C 7 ~ A3D) 'f}'

P,~

FJi~D cfil~UI~~. ~M 01760240g.jT,2 81fUF-3l C-A ~ A-B + ~ ~ FLA HIGH LE\\JEL AL - SAFETY STOP A.C. & D.C. PUMPS I ~~ ~~~/:..~c. ~~;,~'§"'~'~~~~~~~~:~ FPCSTARTD.C.PUMP FLA LOW LEVEL ALARM 6 5 4 3 2 ~-------.---------,------"'- SWl~~AR "_} T01D2 I 1 I ' I '~~~i ~~~FJ~i TR-7 (Y-4) vro ~~iFJ~i~ m;;;10 4200:12() WESTINGiOUSE 1-4 fC1\\ 6 4QG(FFR) TO ~¥i~i~ ~~~lp]AL fOR 86G LOCKOUT RELAY. SEE owe SS-208-218 ~ '-1 ~ Q!! ~:~~) ~ (VJ) VM SWffCH ~ ~ 81(U:;3) a1ru:~21 1"" J 59(0V-2) 4 SEE MOTE D TSS g (VIA) TV::10 ~ ARc-FU-16 (VJA) TV-12 COMP. PT.0940 { 0-1VDC, 0-4 MW ~ POSITION ENGRAVING TS7-D 49!j\\ TS7-E s&~bTE EG-W/VHA 0 0 1 2 J 4 5 5 13 14 RIS HW\\.'20-Pl-EO-C5-X1-f60-WO-Z1-A2 7 8 9 10 16 15 15 16 ~~- CURRENTlRANSDUC£R YOKOGAWA SERIES2283 OCR 1208 ~-* c'l <+ DIXSON I AM MODEL oCR 88101P 4406 (V11) ..,g- ~~2 A.C.AflPMETER 0-600A 49B(TOR) I"" TS7-C T24 TS7-J (T25) 11'-0 11'SA GENERATOR o~~?.'o RELAY 64G(SGO) LEGEND: V DEVICES MOUNTED ON \\.ERTICAI. PANEL Pa. D DEVICES MOUNTED ON CONlROL CONSOLE CR IN MAIN CONTROL ROOl.I DEl/IC£S MOUNTED ON OIESEL. GENERATOR CONTROL GAUGE PANEL ON SKID 0 DEVIC£S MOUNTED IN DIESEL GENERATOR A SKID MOUNTED CONTROL PANEL ID2 DEVICES MOUNTED IN 4160V 1D SWl'fQ-IOCAR (ES) UNIT 2 FDT DIESEL GENERATOR 18 FUEL OIL. DAY TANK 32 (RPR) RE'JERSE PO\\\\ER RELAY FOR ANTI-t.IOTORING PROTECTION, SINGLE-PHASE, \\\\ESTINGHOUSE TYPE CRNt 00 (FFR) FIELD FAIL RELAY FOR l<M EXaTATION PROTECTION, THREE-PHASE, \\'ESTINGHOUSE TYPE KLF-1 SEl..ECTOR SWITCH, EXCITER CONTROL, MANUAL/AUTO NEGATIVE SEQUENCE CURRENT REI.AV FOR UNBALANCED FAULT PROTECTION, WESTINGHOUSE TYPE COQ, CATALOG NO. 1876175 THERMAL OVERLOAD RELAY FOR O\\JERLOAD PROTECTION, ABB ITE-4'1 O\\JERVOLTAGE RELAYS FOR NORMAL VOLTAGE DETEC11Cfl, SINGLE-PHASE, ABB ITE-59N SYSTEM GROUND O\\JERCURRENT RELAY FOR GROUND FAULT PROTECTION, WESTINGHOUSE TYPE COB 76F (FOC) FIELD/O\\IERCURRENT RELAY, DIRECT CURRENT REI.AV FOR FIELD PROTECTlotl, WESTHOUSE TYPE OJ 76FX AUXIUARY RELAY FOR FIELD OVERCURRENT RELAY. a.ARK PM-714UPA 81 (UF1, 2, 3) UNDERFREQUENCYRELAYS. f~ NORMAL FREQUENCY DETECTION. SINGLE-PHASE, ABB ITE-81 81X1, 2, 3 AUX11.JARY RELAYS FOR FREQUENCY DETECTION, VESTINGHOUSE TYPE MG-8 FCH AUX1UARY RELAY FOR FUEL OIL TRANSFER PUMP (AC). \\'ESTINGHOUSE TYPE SG FCL AUXILIARY RELAY FOR FUEL OIL lRANSFER PUUP (AC), VESTINGHOUSE TYPE SG FLH AUXILIARY RELAY. DAY TANK HIGH, FOR FUEL OIL lRANSFER PUMP (DC), WESTINGHOJSE TYPE MG-6 FLL AUXILIARY RELAY, DAY TANK LOW, FOR FUEi.. OIL TRANSFER PUMP (DC) YIESTINGHOUSE TYPE SG X(rs1. 2. 3) WESTINGHOUSE TYPE FT-1 TEST SWITCH X INDICATES SLIDING LINK. TERMINAL BLOCK, SHORTING PINS TO BE USED l'ttlEN WORl<lNG ON THE METERING CIRCUITS - MALE BANANA TEST JACKS NOTES: I. ALL DEVICES WITHOUT LOCATION MARK ARE UOUNTED IN ELECTRICAL EQUIPMENT CABINET.OFFSKIDINTHEADJAC£NTROOM.

2. FOR DIESEL ENGINE CONTROL CIRCUITS FOR DIESEL GENERATOR B, SEE COl..T INDUSTRIES OWG. 11B65841, SHEET 1B **
3. THIS DRAWING IS REPRODUCED FROM C<X..T INDUSTRIES DWG. 0176D240. SHEETS 1 AND 2 AND GAi DWGS. SS-208-219. SS-208-220. AND SS-208-221.
4. THIS ORAWING APPLIES TO DIESEi. GENERATOO 1A ONLY. FOR DIESEL GENERATOR 1B, SEECOLTlNDUSTRIESDWG.01760240,SHEETIB.
5. FOO ANNUNCIATOR WINDOW ASSIGNl.IENTS AND CONNECTIONS ONLY, SEE COLT INDUSlRIES DWG. 01760240. SHEET 2.
6. FCfl ALARM CIRCUITS, SEE CCX.T INDUSTRIES DW11. 11865841, SHEET 2.
7. FCfl AC ANO DC AUXlLIAFtYPUMP ORCUJTS, SEE COLT INDUSTRIES DWG. 11885841.

SHEET3A.

8. ~LT~~lf"firfu~}-d~81rJ~o~llSCONNECTED 50 THAT 59G CONTACT RESETS 'M-IEN
9. 59 RELAY TAA<:ET LIGHTS ARE SLACl<EO OUT AND ARE l<<'.lTREQUIRED TO BE FUNCTIONAL
10. 498 RELAY TEST LED BLACKED OUT AND NOT REQUIRED TO BE FUHC110NAL.

1 REVISEDTOINCORPORA1EE!Jl14-00J20,REV.O. oCR..,, I !+JY YH I EG--FM-2A IT l?J'irc EG-FT-3A G.E. SB1 SW. '3 31 ~ 21 VMSW o,m ~ iii2 G E D c 0 ~ lend FlleNcme :01760240 S1A RJ1 1° EMl!m. Nucli:ar /COLT IND. METROPOLITAN EDISON DIESEL GENERATOR 1A 01760240 1A I 31 ~ A 10 I 9 I 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 L------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

1-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------~ H G F E D c B A GLR 0 10 TO 102 BREAKER m1P cmcu:r GAi OWG 208-163-825 (1X) 6 7 ERB ERA 9 8 7 6 5 4 3 2 1 R[VISJONS TT-7 4160 VOLT BUS REV f ZONE DESCRIPTION A< J! SW!Tfbi~AR j W-5 TT-B IG\\\\ 32 i VAR REVlstO TO INCORPORATE ECR 15-00159, REV. 0. £XCITER SlliCTUR S\\>ITCH MANUAL/ AIJTO MANUAL TT-9 {VRJ) ITS - T- -1Ts-1! jrT-S--8-- - -- - --,--TS=-=.~j----0-_-_1-,~=~- 1 ~-s_1 __ s_2 __ S3_~i j :io~3o T&jj', TO ClRCULA TING FAN TRIP CIRCUIT COLT IND. DWG 01760240 SHT.2 { _A53 A55 9 I TA0-1 K.3 31~.31 TS 8 ITA0-2 _____ '"' ____ r-.., o I 32~32 Qi T4 1 I TAD-3 I ~ i ~-~ ~-~ I C> 43E(M) OCR 2 H0-15 E11 TI-5 1I 43E(A) ~ I gj 1-(/) ~ L3-I TS-11 1 lfS-10 ~ ~ ~ ~ L2 o-~1 1-----B-*-----, i WI~:!: 0 CR 13 E]._O iT~4 !,.... ~10 E7 TT-3 ! ,--O--::;f'>:;-;---e--'-o'-'--07 H0-24 B7~TV 7 87 a:::u~o I wwu>- 1 TV-6 OOIJlz 86o--t---0----0--86

~_J<

i I TA0-6 I 0 >...J~~~ I ~~~ca 3 E n-2 l EG-&~Ast_JJ-FU ~--*-*-----..-+---------..--<-------B¢_ 0~'.T N~. r 1 ~, c~ 201-021 ~-----.-t-+---------.--iC---T--------- 1, 3; _ AO 1 CO. ) LlGHTNING PT1 r-1---t--+--l--1/'Tijz'i._\\ _ ~-J ARR£$TCf.: 1A I '-... ~ SURGE Lf-5416CV ON SKID 80 CAPACITORS ~ t...; 416011 ON SKID = (SEE DWG 11865841) = IA ' EG-Y-1A\\ ARC-fU-1 ,--tl--------~l'~~l)l__~TW~-21 _____ ~:'.:flliiJ;==---~TR~.[;:!7'.__f(\\~~Q) _______.--------.------,r-------,------------11-=, r~=l---:9'----ffi!li]~~~1i:_;Q.A;:(:>;-::---,~-' l 1:1 V10 EG-Y-1A\\ TR-10 g.f'51 C - TS4 C, TS5 D TS1 D TS3 ARC-F'U-lJ WE~E(;~~SE ~ ~i ~ ; l {Vi) ~> 59(~~-l) ~> 59(~~-3) -:,,.. 81(U:;1) ~~ 81(u~;:-3) ~ I: EG-Y-1A-;:.>T2 ~ if.! t£ 5: PT3 4 SfE NOTE 4( SE£ NOTE 4

4)

EG-Y-lA\\ O TS4 S O' TS$ 9 C TS1 C TS3 1A ARC-FU-2 C TS5 D TS2 ADJUST OCR ;---<;~H-0~->-2-6--e---<>-~-08 AUTO TRANSFER .,~-5 es >a:::o Ts=3] TAD 1 O:::c~u TS-3 TY-4 ~Q~ffi 84o--t---0----0--84 ~I vj 3JO--t-+-~ 1-:::-:::-l~f-l-l----------------~---+---f--J I TAD-4 I Ill <( '-- -0 50 ~ t 8¢ _..)~,~------l-------J:i"V'~"---l---~-~'---:::.~rn::::::_ __ ~lR-'l:;:-~'_l(~V5~):__ ___ f-_-+------f------+------f------<r------<r-_J,;3)i~'----v~1>t--'-(V_l.~r') _ _cTR~-~1~1-~oe*N'-_ 3 3 B (V2) > 59(0V-2) _> 81(UF-2) > 59G{0V} 1 CONTRO!. RHEOSTAT MTD. ON LOW VOLT CHASSIS INSIDE CONTROL CABINET A TT-1 '----0--H~0~-~2~7--*~-'-'<>'-+--os P1~TVB P1 fl) 34 1 6 i t;:: I ,_-059~ ~ ~ P2o-;--o----o----P2 J5o--t-l TAD-9 I 1 ~-~ ~-~ 36 o----1-, L_ ______ ~ l ,_ __ PT4 BC4 BC 97, i 0 4 SEE NOTE EG-Y-1A\\ o TS5 9 C TS2 ARC-tu-~ r T L--~c~*<~trr:::Jlf-t-i-1----., /-l-l--t-------~l'V3~1\\----+---+-TTIW~-~3!____::ffiiiij:::::. __ _!!1R8-~2c_(~V~6L) __ t--J.--l-----_j-----1-----_j-----+ 32(RPR} -= 1, ll-(V3) 0---<--~ £G-f-1A-PT1-FU 1A TO SYNCHRONIZJNG SEE GAi DWG E-207-031 DIXSON MODEL 88101P I 20 01 RIS MODEL FCN-18-P1-XC.5-F60-D5

6)

( 5 FM OCR 440C EG-FM-2A FT oCR 120C EG-FT-3A DIXSON MODEL ~B101P~cl,- r E:l~l E1-2 I TPQ3 1<2!-----~'~'~------, 3A (J FUSES) I "- (G1) TR-5 L __ E=G=-=Y-=1:\\iA~\\~ARO:'C=-='"=-='=-*--_J~L!:'-0!_-~:__-.-----------.-----------------i--+'---.--'*-l--l-~G~.E=:,. SB1 SW. ~ ~.-------~~--+-=n=n=c--<J---, {Y1A) TV 10 PT1 j--J '----< ~1 ~I ;i~ll - EG-Y-lA\\ARC-FU-15 1 J... TP-2 PT2 3 4 W-1 TI 5A £KOTER RESET PB-6 * -o 1W ft 10 ~ TO (T2) E21A JP-9 10 64(SGO) I I I I I I 3 x 100--~ i I 1,cs r' D v x I I 02 40G(FFR) 01 TN-10 28 1N-9 7 ALARM-NOT TP4 USfD E21 IB14-2 EXCITER 9C 025 lR-9 Q-~------.~'~'~-.---<XJ--~-021 83 3 v (+)3~ 76F(F'OC) A 7 SH-1 SH-2 ~ 50MV / 5DMV / r-~-'t~~~~~o~:g:'.::agrc-tg::'.:g::=o~o~'t---------i f1 F2 f3 F4 F4 1'"5 F6 F7 10CA D-3 + 5 VARISTOR TAA-11 O----f(F7) 3 Rt 6-4F{FCR) v T3 T1 T2 GENERATOR T4 TS T6 "'--~__.-' : I. I u t-PTS ~~ ~6. -f! (G1) L_ _____ ..:'.:':::::1fi-jill'::::::::':_i(Y~2~A~)_rv:::;~1~1 __ !P~T21---l--.-----------l-----------------------l----l---.---..-l---t'.__-~v*~C___J2C ~ ~~~~~~~BsE-=- 3~ 8,*::6tIB~ L--------~c:o:-:Y:-T=:'"::'"[c[-[FUi]:::-: 1 '::.JC~V3~A~)l!TV~-o'~.2'-_JP~I-~3--l--J.--.----------l-.---------------------1---,,_l-l--~-,_j_'.~3~:3c:;i~T -4C TYPE PTM TR6 TR3 (V9") .PTG inA TYPE 16SB1 Cf11 EG-Y-1A-PT1 40GCFFR) (V7) (VB) VARM 1 5 6 7 ~ EG-VRM-18 II ~i*X-O_N__ f DIXSON I I I I I I I I I I v L ___________ _ WM ODEL i MODEL EG-\\\\M-1A OCR A.lOl BB101P 770 f (+ (-) E1-2 Et-1 J 'o' 4 , -) +) v I I ri T 4 I I I I I I ___ _J (- TB2-4 COMP. PT_ 094V t > 1K 0-1VDC, 0-4 MW OHM -'.JT82-3 EG-W/VT-IA o~ ( ) oo 1 2 3 4 5 s 13 14 RIS #WV20-Pl-EO-C5-X1-F60--WO-Z1-A2 7 8 9 10 11 12 15 16 ) l 0 0 ( ~-----.--...c.,- 0 --010P '------+..... *-+--0

  • gp i

~-----1-oo<-i--01P ~ w ::; ~ 2P a:: ~-----1-----------'>H'--O 3C 6

t:

c-),.___ _____ ] ,...,,._+--0 4C '---------+-..H*-o-7C ~ ri--;.H-o BC T~I OTO ---t ESI ._ _ _,-o j 894-EMERGENCY 0 SHUTDOWN AT MN CR 1 PB-5 EXCITER -. EMERGENCY Q SHUTDOWN I SOR 0 9 !93 825 lR-8 I 3 5 R2 VM 0-300V 5 TAA-100-----<l<FS) [ ___ ~ '+~__,.ct-----"801 __,~GC~o~3 __ TN-o-~2-------------------------~-------~---~'~'C~3~1~;;c--<.>-\\ ~O'-J<"-~'*C~7~'~'"-o-~'-,-.,.,-----+, -~~~~-+--------t----+--+-----+--- TS7-H 498 TS7-I Gc34 WATT/VAR (TOR) SEE NOTE 10 TRANSDUCER I A +:'\\ /"n\\ lN-11 i ~ORA I I 10A ; F'J-6 : 0 i lV) (1P) 010 ES2 ~-_,-o EG-Y-1A\\ ARC-FU-9 JP-10 TB14-l 22 i E2*2~A------E42r2--~ (22) I CONTROL ~

  • ORMAL AT EN~lt-;E tcil 814 BS E 0 TT-10 t

--o------+---o-~ 20 __ B+ 1319 RS-~ 821 8-J ~---~c--~ i B GC2 Bl TS7-f 49~ TS7-G

JC24 I-(TOR) SEE NOTE !O

'.J-~--t--if---~Ai-----~B>1 __.,,.~~'--.Q:-24~r~'Clt't_~8i---l\\',--i'O-----------------~---------~l~C~<.L_'<8)-l\\,~R!)-'l~C~5cL'~~ TN-1 ~ 40G{FfR) J2(RPR) TS7-D 4gg TS7-E GCl 4 F+ F-8 'TOR:) S~E NbTI: T28 (" P TS-8 T30 1 P 30A TS-7 T27 ~ -~~~*-+--'~sc-~----------------------~*~1~0~----,*~*f-'o'--t-~Bo71.,,T'~~o~:"_A_L_i'J._;;ENrtr.~*JE,--:<.r--'*o-~ru,_--'~ L ES1 RS-! B, G28 (1N) -o ES2 -o -12{C3) HD-2 TW-12 T59 T19 LSA


~Bl--'~70~_,

7M B9 H0-3 HI RES R 459A O RES 13 13 16 7 7 5 TU-12(54) T46 6 6 B I ~ 87 r---o-87 (BR) av G 7 ENGINE RUNNING SYNCH, SPEED IND. AP1 ?~i~*o~-.--"-<0,.-_ 1 _-<,,Ac:_-"'-@~-' -_6 RES G2f! ENGINE ST AP2 PS53JB CRANKING IND. I s:_:~ I s:_:~ I s:~; 1I s:~; I 5;~ I s:~ "= 1 m '0 = rtB 1 m 2 m 13 16 16 7 5 5 59X1 59X~ 59X3 59X1 59X1 59X3 59Xt 59X1 59X3 59X2 59X3 59X2 8-C A-C 8-C T50 3 J T48 4 T45 6 B A::s T A::s A-C 'f A-B I A-B I A-C A-8 A-B A-C 9 10 10 2 2 3 4 4 ID TI7 TW-11 0----~--+----; TS-1'1 0--0>'"---1---- 5-> TU-11 0---9----+-----. !3 13 l6 7 7 6 6 8 I 8~~~ I~~~ I 8~~~ I 8~~; I 8~~; I 8~~; s~:~ 8~~~ ~:~ g T56 g TSO lO T52 1 T16 1 T20 2 T22 3 T48 3 T47 4 T49 13 16 16 7 5 5 6 4 4 81X! 81X1 81XJ 81X1 81X1 81X3 81X1 81X1 81XJ. ~-~"o-'---"_,o,.-_, ___ --< /G,.--;-4-59-ICRREE!s5j-~>--HD_-_, __ 8-c7>--<12>-_rw-C-r10_-;'o!';"--1-;0:9;: __ '_0" 2 T15 2_ 3 8 T42 8 l A-C A-8 A-C IT A=B f, A-8 T A-C A-B A-B A-G ORES 5 GO EG-Y-1A\\ ARC-FU-7 DE\\llCES 59X & 81X lN TS-tO(C2) TU-10(RCA49) ENGINE READY TWO OUT OF THREE MAIBIX TO LOAD IND. TC INO!CAT£ THAT GENERATOR DEVICES 59X & 81X IN DEVlctS 59X: &: 81X IN S P To SPE"""- TWO OUT OF THREE MAIBIX TWO OUT OF "THREE MATRIX 1 U .:.v AND VOLTAGE TO ALLOW Q..OSING Of 1D2 TO INDICATE THAT GE:N£RATOR SRf:AKER lMiEN GENERA TOO IS NOT UP TO SPEED IS UP TO SPEED AND VOLTAGE ANO VOLTAGE FO.G: es INDICATION GAi DWG C-208-163 GAi DWG SS-209-438 TS-4 PN (T14) 10A (l3) Tl' '0 E TS6 E TS5 E TS4 E TSI E TS2 E TS3 TAA-4 11 0 11 0 111~ 111p tHO 11 II 10 ) 10 )

- 59(0V-3)CA __ ?9(0V-:2)8C

-~ 59(0V-1)A9 :,... @l(.\\:![-:_Q6.~- :- 81 (UF-2)SC 81{Uf-3)CA

76f(FOC)

._ 59G(OV) SEE 12(0 12 ' 12<?) 12(~ 12(1) 12 0 ) NOTE t B TS1 F TS6 F TS5 F TS4 F TSI F TS2 F TS3 TS-*1 ( TS-2 TS '.:l TP-*12 TP-11 W-9 TAA-6 7 l 81(UF-1l TS-6 N 10' 10 10 ) 12 ,?59X3 >59X2 <>~ <>s1x1 EG-Y-1A~ 1 7 ARC-FU-11 0 11 ) ~ 0 11 (T13) 10A (T!2) rs-s lF-9 PN T 2 OF-LS-244A FFC fDT e T33 T34 1 ' TF-3 OF-LS-243A flA FDT T35 DF-LS-243A Pc A FUT 9rF-6 9' ..L. FCL 3 brr: 0 12 <>~ 0 E:::__ 31~

  • T !'bh. "T 12

< >e1x3 7, 11 1 <>76FX

2)

B 10 fF-8 FLH FCH i ) 7 A-B ~[ <> 5-QGX 8 w L g~ 0

8)

A 151 ~ I 8 TS2 B TS3 76 7 81{UF-2~ 8-C 8 8 f-- - f-- A TS2 A 153 ,:fi6~(FGR) 1µ2 TC-9 FIELD GROUND ALARM SEE COLT !ND. OWG 01760240 SHT.2 8 TS4 ~- !lliYF"-3) i 59(0V1). C-A ~- A-B A TS4 9 TS5 B TS6 -r--:

7) :

!7 )

  • ~~

8

8)

A TSS A TS6 59(0\\13) C-A Bl GCO TN-8 IGDLN\\ B1 GOLN l J _C fDJ) 81 GOLC '+-"-----~~-~-o---~-t--- i TO GENERATOR O!FfERENTIAL t, PROTECTION SWGR. 102 GA! DWG 207-021 FOR 86G LCCKOUT REL.A Y. SIT OWG SS-208-218 GOC.8 VM SWITCH POSITION ENGRAVING 't---+--lf--t1A-~f<~0~1~'-~B~1--G~D*L~A--J CONTACTS HANDLE END i HAND:.E POS..

{BA-CK \\4f:W)

I i i B¥TS 7 + ' 70 498\\TOR)

8)

A TS7 4.3 2 1 JT l'N-8 1 r-1 r-o o-j r--<j12 ic~-+-x+--xr:+-1 3V TN-5 /CA3' g A g {CA1) lf.:>._2_ ~~--- Jb-_, 1--o---o--l ~4-1--'!-+-x+'xt-H G.E. CO. SB1 SWJTCH NON-SPRING RETURN KNURLED HANDLE tn 6COA-4 OHi.iS ~ 24-00V FOR 1 MIN. TP5A Tl'-6 TS7-C T24 11 498 TOR 12 TS7-J {T25) TP-5 T1'5A GENERATOR THERMAL OVERLOAD RELAY v 64G(SGO) LEGEND: 0 0

  • 0 102 FOT 32 (RPR) 40G {FFR) 43 460 498 (TOR) 59 (OV1, 2, J) 59G(OV) 59X 1,2,.)

59(JX 64-F (FGR) 64G (SGO) 69X1 76F (FOC) 76FX 81 (UF1, 2, J) 0-100A DEVICES MO:JNTEO ON VERTICAL PANEL PCL DEVICES MOUNTED ON CONTROL CONSOLE CR I~ MA~N CONTROL ROOM OEVlCE-S MOUNTED ON DIESEL GENERATOR CON'!ROL GAUGE PANEL ON SKID OEVlCES MOUNTED IN DIESEL GENERATOR A SKiO MOUNTED CONTROL PANEL OEVlCES MOUNTED IN 4l60V 10 S\\\\'1TCHGEAR (ES) \\JN!T 2 DIESEL GENERATOR 18 FUEL OIL DAY TANK REVERSE POWER RELAY FOR ANTI-MOTORING >=>ROTECT!ON. SINGLE.-PHASE, WfST!NGHOUS£ Ttf>E CRN1 F'IELD FAlL RELAY FOR LOW EXCITATION PROTECTION, THREE-"'HAS!::, YESTINGHO'.JS TYPE K!._F-1 SELECTOR SWITCH, EXCITER CONTROL, MANUAL/AUTO NEGATIVE SEQUENCE CURRENT RELAY FOR UNBALANCED FAULT PROTECTION, WESTINGHOUSE TYPE coa, CATALOG NO. 1876175 THERMAL OVERLOAD RELAY FOR OVERLOAD PROTECTION, ABB ITE-49 OVERVOi. TAGE RELAYS FOR NORMAL VOl TAGE DETECTION, S\\NGLE-PH..<\\SE, A8B !TE-59N ~ OVERVOl.TAGE RELAY FOR EXCITER SHUTDOWN, SINGLE-PHASE:, WESTINGHOUSE TYPE CV-7 AUXIUARY RELAYS FOR VOLTAGE DETE'.CTION, WESTINGHOUSE TYPE MG-6 AUXILIARY RELAYS fOR VOLTAGE DETi:CTtON. 'NESTlNGHOUSf'. TYPE. SG f"IELO GROUND RELAY FOR GENERATOR FIELD PROTECTION, Y.£STINGHOUSC 1YPE DGF SYSTEM GROUND O\\'ERCURRENT RELAY FOR GROUND fAULT PROTECTION, WESTINGHOUSE TYPE COS AUXILIARY RELAYS FOR REMOTE SHUTDOWN SYSTEM ISOLATION FIELD/OVERCURRENT RELAY, DIRECT CURRENT RELAY FOR FlE:LO PROT::CTION. WESTHOUSE TYPE D3 AUXILIARY RELAY FOR FIELD OVERCURRENT RELAY, CLARK PM-714UPA UNDERFREQUENCY RELAYS, FOR NORMAL FREQUENCY DETECTION, SINGLE-PHASE. ABS ITE:-81 10 NOTES. EG-CT-2 C-) I (+) T82-5 :.--l CURRENT TRANSDUCER YOKOGAWA SERIES 228.3 OCR 1208 I i 1K J! COMP. PT. 09+2 OHM 0-1\\IOC, 0-600 AMP TB2-6 ;::.----- IE1-2 _( E1-1 (- (+) i DIXSON I, MODEL i 88101P A.C. AMP METER 0-600A AM oCR 4406 EG-AM-2A I. AU. DE\\<1C£S Yl!THOUT LOCATION MARK ARE MOUNTEO 1N ELECTRICAL EOUtPMENT CABINET, OFf SK!O IN THE ADJACENT ROOM.

2. FOR O!ESEL (NGJNE CON1ROL CIRCUITS FOR DIESEL GENERATOR 8, SEE COLT INDUSTRIES DWG. 11865841, SHEET 19 **
3. THIS DRAWING IS REPRODUCED FROM co;..T INDUSTRIES owe. 01760240, SHEETS 1 AND 2 AND GAi DWGS. SS-208-2t9, SS-208-220, AND SS-208-22!.
4. THIS DRAWING APPLIES TO DIESEL G"::.NERATOR 1A ONLY. FOR DIESEL GENERATOR 1B, SEE COLT INDUSTRIES OWG. 01760210, SHEET 19.
5. FOR ANNUNCIATOR WINDOW ASSIGNMENTS AND CONNECTIONS ONLY, SEE COLT INDUSTRIES DWG. 01760240, SHEET 2.

e_ FOR ALARM CIRCUITS,_ SEE COLT INDUSTRIES owe. 11865841. SHEET 2.

7. FOR AC AND DC AUXILIARY PUMP CIRCUITS, SEE COLT INDUSTRiES DWG. 11865941, SHEEi 3A.
8. 59G RELAY SEAL-IN CONTACT IS DISCONNECTED SO THAT 59G CONTACT RESETS WHEN VOLTAGE DROPS BELOW SETPOINT.
9. 59 RELAY TARGfT LIGHTS A.~E BLACKED OUT AND ARE NOT REQUIRED TO SE FUNCTIONAL
10. 498 RELAY TEST LED SLACKED OUT AND NOT REQUIRED TO BE FUNCTIONAL.

t GC11 GC31 Tail-10 GC21 TBH-12 L.,. ___ _ GCO I Cod Fil* Norn* '01760240 S1A R32 VM cJcR 2 4 440A £G-VM-2A VMSW OCR 449 Ol'Cl 754 TF-1, Tf12 +/-Cl!! 7 T'2 TO AC FUEL Oil TRANSFER PUMP CIRCUIT SEE COLT IND. ~ FUEL OIL DAY TANK HlGH OR LOW ALARM SEE COLT IND. DWG 01760240 SHT 2 SPARE 2 2POT 2PDT FLA FPC 81X1, 2, 3 FCH FCL FLH FLL AUX!UARY RELAYS FOR FREQUENCY DETECTION, WESTINGHOUSE TYPE MG-£ AUX!UARY RELAY FOR FUEL OlL TRANSFER PUMP (AC), WESTINGHOUSE TYPE SG THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE lT MANUALLY Exelon. Nuclear I COLT IND. Tf'-10 1 I FCH 9 T31 i 7 79 7 FCL FCH 8 8 12 T13 N T 3 OWG 11865841 SHT 3A FLH TF-7 TO DC FUEL OIL TRANSFER PUMP CIRCUIT. SEE COlT !NO, DWG 11865241 SHT 3A FLA HIGl1 LEVEL AL - !'PC STOP A.C. & D.C. FPC START A.C.. PUMP FPC START D.C. PUMP FLA LOW LEVEL ALARM SAFETY STOP A.C. PUMPS & O.C. PUMPS 0 X(TS1, 2, J) x © AUXlL!ARY RELAY FOR FUEL OlL TRANSFER PUMP (AC). WESTINGHOUSE T'fl'E SG At!XlUARY RELAY, 'JAY TANK ~!CH, FOR fUEt. OIL TRANSFER P:..:MP (OC), WESTINGHOUSE TYPE MG-6 AUXILIARY RELAY, DAY TANK LOW, FOR FUEL O!L 1RANSFER PUMP (DC) w£ST1NGHOUSE TYPE: SG WESTINCHOIJSE TYPE FT -1 TEST SWITCH JND!CA TES SLIOtNG LINK TERMINAL BLOCK, SHORTING PINS TO BE USED WHEN WORKING ON THE METERING CIRCUITS MALE BANANA TEST JACKS NO. DWG.. NO. 11TLE REFERENCES METROPOLITAN EDISON DIESEL GENERATOR 1A 3-LINE & SCHEMATIC DIAGAAM DWG. NO SHEET REV. TMl-1 01760240 1A 32 -SCALE: NONE 10 9 8 7 6 5 4 3 2 1 H G F E D c a ~ z 0 A L------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

A B c D G H K 16 d~j ~t!)'C!l' Cl~~ ~i~~ .. et;~ ~~ ~~~~ ~Gjffi ~ ~01 ~E "w "~ "11' (zp) (P) (N) 15 FUI l!. - l!. FU&b. FU5b. FU4b. FU3 l!. 1r 14 13 12 (GL) (GL2) (GL3) ~ .421 _l43M 0 T"""""il ~ §_ !§: ~,w!i §_ ~f-- -----1--t--+-~ ~ ~D O 1 ~ 208 -168 §_ §ii D I 1 I ~ a~ ----- -~ ~'1~-- I '31 82 i ~ '2 ,SI 208 -168 D 1FA §_ I-~ ~~i:-T §I ~ ~ D -fa-(&E) ~I 2C 2CA ~ l!. !.>A l!. 2FA Ifill l!. .11 fillB l!. '!:l!l film {:,. &-I~ Ml {:,. AA l!. l!. 10 i S~R i-tW ~!' ,fr l "' l "i:! !Lffi ~ ~ "mi~~Bl I ~,_ ~.. ~ ~r ~00 ~, I ~ "'o [ ~~N Ii~~!,_ o .JgH:f*l~-t §<J ~I ~:t~ ffia _,.,.GROUP 2ES TEST -J-+-+---i--+-++c:-NORMAL .5m:Q. Elw ~~ Sf5 (GP) (si> l4Pl ix ~ ~ ill ~ cl* )', ,g~ ~ 22 w

8;
:; a:
Zuio:.

~ ~::Ed '-'~I-' In RESET~ -T i ~ ill g ~ "'z o: ~8::; 1-

i.!

0: It ~~~ ~ l!. (41 BB l!. T3C l!. ~ ~ ai~ ~~ <Oil.. lll::z '70 >w ~~ ~~ QE! -........_GROUP1ESTEST 9 ¥ S<* g ~... ,,o O:::ci ~d l!. t !L6G D ~ 5A l!. ~~ ,<J

?~

~ ,y

z 8

_i l!. (3F) )-\\'.. ~*.~ )-\\'.. ~ l!. g iii !I 5 f!I ~ ~ l!.

i

~ ~ 3 0 -~~ WJ z4 -:I

  • ~

l!. g ~ £ 0~11 ~Q~S j ~ ~ '1 w 2 ;;; OP3 CPLl!t.

  • g

~ ~ m ~ 6 SETTINGS: OF TIMED RElAY:- nA 9SECOlllS:!:ISECOND TlB 9SECDNllS:!:ISECOND TPPU T3A 20SECDNDS:!:25ECONDS: TDPU T3B 2DSECDNDSt2SECONOS TDPU UC 2DSECONDS:!:2SEi:DNDS TDPU TOL 180SECDNilS:!:lliSECDNDS TDPU 181SEOONDS:1;15SEC[llO$ TDPU 69SECDNDS!IOi!ECIJalS TDllO TS1 AIR START VALVE TEST SWITCH NORMAL EG-V-16A/A DEFEAT (AS1) (f) EG-V-16BfA DEFEAT (AS2) SIDE2 SIDE1 SIDE2 4 SIDE1 POS2 POS1 POS2 POS1 POS2 POS1 I.;-'-; i o-1-o I lo'olo'ol j,n,lo'ol SQUA~~~T~ ~~~~~~~~~t~~AlNED RESISTOR BOX TA.CH. GEN. 2 POSITION KEY SEI ECTOR SWIJCH (P/N KS11K2H2, TYPE E CAM) SWITCH NUMBER ESTS-M ~s~Ef1~~~ 'JERllCAL KEY ~a:LO, <.;"i'E1"""" Z_hZ"ol ftL'-j,ff01 --:: "___/'---~~J SIOE2K c~~iA~l~.) co_~J~{(m..) 1'L,l\\2.Lo\\ PYROMETER u*. TC IHERMQCOUPLE. IS THE.~MQCOUPL£S (oNLV OtJC SHOWN) 1-1'2. /ND. CVL_ KH 13-14 TU/f!BOS /.SCtJ/"J/31NE'.D Ex;! (1RtJN COJ.J.STANTAN) (4K) 2CA (SA.) 3 LEbiEND: DEVICESMllUlffEDDNDIESELGENERATORCllNTROLllAUGEPANELONSlllD 0 REMOTE MOlJl'!TEQ EQU.IPMENT i GENERAL SEMICONDUCTOR '"lf" !NDUSTJ<IE.:; TRANSZOl<.'e P/N JANTXING>071A fl - EQUIPMENT LOCATED ON DIESEL GENERATOR SKID (NOT IN GAUGE PANEL) \\J - EQUIPMENT LOCATED ON DIESEL GENERATOR SKID (IN TEST SWITCH ENCLOSURE ON LEFT SIDE OF ENGINE MOUNTED RELAY CABINET) NOTE&:-

1. THIS DRAWING APPLIES TO DIESEL GENEATOR 1A ONLY.

FOR DIESEL GENERATOR 18, SEE COLT INDUSTRIES DWG. 11865841, SHEET 18.

2. TEST SWITCHES "ESTS-M" & "ESTS-0" ARE SHOWN IN TI-iE NORMALLY CLOSED POSITION.

REFERENCES:

GAI DWG. 210-491 ELECTRICAL CONNECTION DIAGRAM ES TEST SWITCH ENCLOSURES 3 POSITION KfY Sf! fCTOR SWJJCH (P /N KS42K5E131-12.. TYPE B CAM) SWITCH NUMBER ESTS-Q LEFT KEY POSITION

~~~~l~~~

VfRllC~o'.fI)OSlllON ~~o1~EY ls~ON q

o: o! :~~liiTol ro=1-c;1 1o.EBff5T~

Z,-"-._,, ----- ---- ~--~*' 1FA 2FA 1F 2F --;-f-1FA 2FA 2F SIOE 2 KA1 SIOE 1 KAI CONTACT (TYP.) CONTACT (TYP.) FUSE INDEX DIESEL GENERATOR SKID PANEL FU1 '~GL3--STARTLOGIC GL2 -- START LOGIC GL -- STOP LOGIC 4P -- GOV MOTOR -2? 5P --SHUTDOWN LOGIC 5P--

  • -+-{jjiKJ<---1V -- EXCITOR G28 -- (COLT IND. DWG. 11865841 SH.3A)

-03 QO--GEARBOXHEATER QO--(COLTIND. DWG.11865841 SH.3A) 6P -- GOV HIGH & LOW IND. LAMPS A B c D E I~ G .~ -:~o~ ~ t>-1~1 ~r~ r&I ctP*1 'WT,,. "'lru1 '{'; ill {:,. OTLA l!. A~A AVC {:,. F~~~f.~-- 1~~s ~Iii~~ ~iffi&t ~~5~ ~~~i >Wilt!;.: 1'12WO !:!WO..>!} ci._: g1' w !:::4'SPL.ICE i ,,;:[~ e?~ l!. l!. tCI j_fil ...... {;; ~ 6. ~Igt JI~ T !!. OLLA l!. !!ll -o----~"~~~~--------+-----.._ _ __,,_ _ _. __ __.__-,--+--__.._ _ __,,_ ___ ---,-,---<>---+---+------,---+---+---.._---<,_-,----:'>;------,---~----:'~---+-~-+----...... -*~*~ w ~ fi1 I-I- ~'--v-----1 ~ _J ~>- 1-- ~~

rq o,_

~j ~J '.l

=a

i 9ci ~ g~ ~ ~~ g

5

~ $z ~~ w ~ ~ S 1:l!1t B'. ~~ 3 ~ i~ ~ ~~ ~~ ~2 s~ a~ ~ IB m~ ~ ~~ ~§ ~~ §~ ~ ~

!5

~~ ~~ <.)...J (.l:J: a: 5:r ...J 2 t.!12 i5 ~ ~t li ~ili -~~ ~e 9~ l:iia: ~ 8~ ~~ ~ ~:! i=~ ~uJ2 _J ~~

i iog 4

IO~ cti.!J ~:::i ulll ~~ ~ w9 <CW fO al~ ~UI ~~~ ~;, ~~ i5 3-1 li; 3...J 57 [5~ ~!f .,!=' a! 3 5~

i
J.:i ti;~

lfi>O u.9

  • J SHUTDOWN

~H=l"-o"0

  • 10*

r;* 20' METROPOLITAN EDISON DIESEL. GENERATOR 1A THREE MIL[ ISLAND NllCLE.AR CAD FIL£ NO.: 118658+LS1A_R29 j STATION UNIT I 11-llS IS A COMPU"Tm GENERATED DRJl.llnNG, DO NOT REVISE IT MANUALLY. T11l"- ELECTR1CAL ColtWu.str112S n...ob<.tik.5 MmH f'o1110S>15to:M.\\JnllSIC>' H C.OltTROL OR8* SQIL.li: "ONI" I oiE.~tM:J~fNE ~*uo. .m,.oa LG K ,......cu c.. 1> a~ !EAT.fll.. (~~....,. ............., olll**~ F~otT.......,.M:*INH*<' t 1/6< CASO. IVIT\\ ou.;!~::s:-:~-:::~'~!~;' _, ::. ml!. .:-;*;:':":'":.*~~. :;'D.. Ii 865841 ~m 1AOF S,

A B c D G H 16 15 14 b~~DG TaE>*ll = ._~J><fj4 ~*,t.TB"*l'l. ~ FU3 ~-+-~a&-u. ~~F\\R rs:.-1~~ ~ &T&ve 28 _ 10 FUI u&r:-S:K~" T1"-~1b OLA 13 <;L C.L2 12 II 10 .41'

  • T!"-13 filIB
li

~ G,LA tL..i.~ <;;I TBl4-4 r mT J 1Eo roe BEiG ioTIE3 Bi. Bl? (3F) 11313-1

  • 2-al J*'-1 T.. 74~ SOR 4A I I

)-\\:.. ~~~ )-\\:_ Wcl ~.. ~c.'J(!;' o~;_ w>-z ~~~ wWW z~:Z <a'-"C!i zzz www Ci! ~-ot_Jo --- ~ SI '11 .$1 <'~I fill * 'TB20JO .. rJ ~ { ~ I iJ"" I r f"~ ~~J f!ll ~J !Jg ~o.j ITEM ~~ t:t;;1--l

  • ll-1. z:g1 4588 G,L.C.

~ //;!\\/) a JN-27 TB{, 1S' 811

=c, 11

~~ ill~*br 18J" -+- q '-9Xb bG -rn;..u, I i6G,-~S ~~ I I,,w ' I I ~~~~7* ;-1,_ §<J TBl4*3~ + v _,J ~ ~- 1C 821 _g1 ~I gl ~"" v ~~

Si

~1 m ~I 3 <t~

~~~

f tn~~ ~~~~ '°4:>-a: ~~~~ ~~c.::~ ><!JIY;> lfl2UJo ~Wll..>!J ~ ~~ 2ici 0W1 ci~ 13 p (z.p) PN ~2. (N) 'il 8' il2

  • ES~

6 '7 '"A (ae) 2C 2CA ill 6 .I.SA 6 ,..~GROUP 2ES TEST -t--+-+---t---+---J-+--:-NORMAL -......._ Gl'<.OUP 1 ES TEST ES~-Q SA ~ ~cl>- ~ ~ g =t~ ~ <!I~ ~ ~ '°~ ~ z z ~e ~o ~ g;~e~ ...l~ ~~. ~ <Li ~8;:; ~ ~ UJ~ ~ci ~~ ~g~~~ ~0 ffi ~~~ ~ ffi ~~~ ~

i
? ;~

~~ ~ui ~~~~~ Zz ~ a:~ci ~

?:

DJ.-"" I- ':!o. on.- .:ta: <..'JVHIJ~ ___?" 8w w u~>' "' w u~ ~ ~ mm (5p) FLIS (900 R?M) ~T2~Ef.M~~_.,./i w ~*SPLICE ~ ~ (4p) 4P RESET PB4 -.- TIA (4L) BB IX. OPI OPL2, 10PL3\\ '">:[- -.-- L)j. ~ ~ -;;[~ ~ !.lfl CCPZ. ClP3 <:(,\\ ,,;;T 1.!El~ CCI ill ~I: '"'[ ~~ EDS ~~l ~ j, ~~ ~~

  • ~

~~ ~: " ~* " ai? Io o>' "e M rL g 0 " ~ ~

,a

9.ci ~... ~ i ~ ~~ ~ "'~ "' ':;~ o;;

1 1

w'° § 6!; ~ ~~ u I- ~~ -'_J ~ 3'.:\\ t:; SHUTDOWN !fl"c1'-o"f0,===i;;,,===,i;;,,===,i;;,,===!,,.' ~ ~ ~11' .~~ w~ z" ~"' 20 wz ~ ~ ~ " ~ ill,& g ~ OPq ~ CPLP. !'.) OPLS m1 i~ Q&I J..r&JI l.!D

i if g~
g~

3 .,:r .,'2 <lI ~vi g~ SIDE2 POS2 SETT I ~GS or TI ~[O T:lA 7SECONDS I SECOND lOPU 7SECONOS I SECOND TOPU OSECDllDS 2SECnNOS 20SECDllDS 2SECOllDS T3C 20SECONDS 2SEi:DNDS TDPU TDL 1ROSEGDNOS t5SECONDS TIJPU SOSECONDS 15SECONOS TCPU SU SECONDS ID SHONDS moo TS1 AIR START VALVE TEST SWITCH EG-V-16AIB DEFEAT (AS1) NORMAL (!) SIDE2 POS2 EG-V-168/B DEFEAT (AS2) l~i"'"°I l;-'oi~I 1~:o"o1 SQUARE DTYPE 9001 3 ?OSITION MAINTAINED CONTACT KEY OPERATED SEL SW -RESISTOR BO)( TACH. GEN. 2 POSITION KEY SELECTOR SWITCH (P/N KS11K2H2, TYPE E CAI*) S\\\\HCH NUMBER ESTS-M VERTICAL KEY POSITION LEGEND: DEVICESHOUNTEDONOIESHGWERATOR!:ONTROLGAUGEPANELONSKIO DEVICES MOUNTED ON CONTROL CONSOLE CA IN MA IN CONTROL ROD~ -+- DEVICES MOUNTED ON OIESEl GENERATOR D RE~OTE SHUTDOWN PANH IN IE Sll'ITGHGEAR ROOM 1E3 DEVICES MOUNTED IN 41Bnv IC SWITCHGHR (ES) UNIT 3 Y~ - GENrnAl SEMICONDUCTOR '4f INDUSTl<IE.0:. TRAN::>ZOl<B P/N JP.NTXIN~OllA

6. - EQUIPMENT LOCATED ON DIESEL GENERATOR SKID (NOT IN GAUGE PANEL)

\\1 - EQUIPMENT LOCATED ON DIESEL GENERATOR SKID (IN TEST SWITCH ENCLOSURE ON LEFT SIDE OF ENGINE MOUNTED RELAY CABINET) NOTES:

1. ALL DEVICES WlrnDUT.LOCATIONN~fiKS ARE MOUNTED IN DIESEL GENERATOR B SKID MOUNTED CONTROL ~ANEL.

(GAi DIG. C-21 0-0~6) 2, FOR T~REE LINE DIAGRAM AND EXCl1ER CIRCUIT FOR DIESEL GENERATOR B, SEE COLT INDUSTRIES OWG, 017BOZ4~, SHEET 1 B

3. THIS ~RAWlNG IS REPRODUCED FROM COLT INDUSTRIES DRAWING 1i865B41, SHEET I.
4. rnR ELEMENTARY OlAGR~M OF Gil-OZ DIESEL GrnERArr:n 18 BREAKER, SEE

~Al DWG. 208-164

5. FOR DEVELOPMENT OF AU~ILlARY ~HAYS SB~. SEE GAi Dlli'G. 208-159.

B. FOR ALARM CIRCUITS, SEE CDlT INDUSTRIES O~G. 11665841, SHEET 2, 7.FORACANOOCAUXILIARTPUMPCIRCUITS, SEECOLTlNDUSTRIESDWU. 1186584!,SHEET3B a FOR ELHIE!mRY UIAGRA~. OF HrnorE SHUrnOWN El\\ERGENCY OlfSF.L crnrnATOR E - AU~ILIARY RELAYS, SH GAi OWG zaa-JS~ 9 THIS DRAWING APPLIES TO DIESEL GENERATaR 13 ONLY FOR DIESEL GENfRHOR IA SH COLT l~DUSTRIES DWG 1166584\\, SHEET P,

10. TEST SWITCHES "ESTS"M" & "ESTS-Q" ARE SHOWN IN THE NORMALLY CLOSED POSITION.

REFERENCES:

GAI DWG. 210-491 ELECTRICAL CONNECTION DIAGRAM ES TEST SWITCH ENCLOSURES 3 POSITION KEY SELECTOR SWITCH (P jN KS42K5E1 3H2, TYPE 8 CM!) SV1HCH NUMBER ESTS-0 LEFT KEY POSlllON (~~~~~ J_ES TEST) VERTlC(~oryAt)OSlllON RIGHT KEY POSlllON A B c D .--~~~~r:~2,--, ![J_ "t-!~! 2C J-"'-~-;~~.J ,,A ~i~ 1~:1 i~l i~:1~01 r~::_~1 r~N~"j:~l Z ffffA~"Y'---3[~" 1FA=._5/2FA~lF "- SIDE 2 KA1 SIDE t KAl CONTACT (TYP,) OTLA _J ~* ~5 _J~ 0% ~~ ~g OLLI\\ (4K) A~A Y 1\\1/C ~5 ~~ ~~ ~~ ~" a'b ~~2 ~~* FPLA n::/ CLL/\\

I!

~ ~ _J w;o

io

"-~ ~ §~ ~~ CONTACT (TYP.) ~R ('431) l(c:i30) ~a ~~ tE "~ Hilt ELECTRICAL SUIEMl\\TIC. DIE":.\\:.\\.. ENGIN£ U.lffROL D T< Coltiooust.rt(l.S G H fu.,bo,nk5 rJloru P,,'"~' Sy*t"-'"~ 01Vl5*<>n K s~nr !9 OF 3 (**"'"~...,......... r*' I ...... ~....,.., *. "I I'" 1 '1>0C O<<'<>< ooi Af'W. -~ '"'Hl<t>tl>".01>><<~>'*0, NlOO~*~ .. <c.. .~:::::~'.:~;*;;.,;;::~-"'Db!' I ' 865841 I o.; *",, 030 "'", *"" ~,,_, I

CXI o-(J) eN Ul a~~~g

  • co;!*

f=!:: -<*~... ~ ~CI~~~

~~

S!'i<n .... s~, -:0 ~- :. ~~~~: n 0 ~ ""

z:=ia~

nip ~a~ i Olci' ~.. g ~

a.C
OE
u~

,...,.o a zO-.,n ~~=i~ hiJ tv!l X. I i I ~ I 0 l§ (Jl (Jl VJ ~~ ---.J VJ -o c ~ I J i I ~ I~ ~t' ~- ~ l- "'<* -*m


,\\

J ULD 2.1 ~I c ~~~~ ~ . ~ ~ Ill~ ;: ~ J. !~ rl ~ g--1 _:.r=JJP~5 ~ m o rn-1"' ""U J:>"J>'V -~o~ 1 o ~r;s~§~ fll z J' m 'l: 1J G z ~-~ o ~~gj~~ih ~ nVlf'\\- -ufJ< z §0~ ~ ~--1~1 ~UJ~

  • %~r:.-<-~ Alps

~'-1 8 II' 3 C'J (11!;. ~ z v; -~ ~ ~ -j ~ ~~ ~ ~z~ ~ {f) ~~ rv W P-z ~ ~~ ~ ~ 0

\\)

? 0 ~

2.

G) U~D 10.2 Ill r, CONTRO STAT~8N TRANSFER 10 MANUAL t:llt (SEE GAILEY METER D\\VG. 0553854 @ cCR STAR LOGIC RE_ATED TO INTEGR/-\\ TED Ul D '3.3 TRANS~TR ULD CON-IR:JL STA riCN TO M;\\NUAL REFERENCE DWGS.: iJ '\\liT LOAD DE.MAND D"i:VELDP!o£NT ANALOG LOOIC 0\\o.IG, D!353729 Ut\\. IT.LOAO DE.MANP OEVfLOPMEtlT 'DIGlTAL LOGiC PAR; 2 t:llt ULD 1.4 IS UNIT MASTER IN CONTROL PC~ ULL.l 8.3 '? (s) RC PUMP y FAILURE ULD q,4 NO ARE ANY 3 REACTOR COOLANT PUMPS RUNNING! NO ARE A~V 2. REACTOR COOLP.NT PIJM?S RUNNING? LOAD LIMIT OPERATION YES () ULD Y. 5 TRANSFER UL 3.3 ro UL S I ULD IO..S TRANSFER tJ ~ 3 r::: Ul_ 4.! ULD \\l.S TRANSF-ER U~...- "J

  • --: TO U'_ 3.1

() ULD \\0.6 BLOCK MW CALIBRATI~G INTRSRi\\L C 7.0 BLOCK REQUIRED R=-F

  • ll.l 2.5 0

U'~V r.l IS UN IT UNDER CROSS LIMlTS PER ICD3.3 f NO ULD 8.1 YES f ARE BOTH GENERATOR BREAKERS TRIPPED? (DWG. 229-081 & 082) NO lJLD 10.7 \\jLD liD 7 TRA,'I!SF=R U L '-1 :-".TO UL"-1*7 OLITPUT 0 00 o-01 w tv

1 0> t I* I I tJ. I I 1;1 I"' I Ufl.l ,1

  • ~........
  • y*L' :*

~

  • ~

~

  • 1

~~! '1 "*' ' 1 z ~. -f m 'm Gl }( i\\ ~ (I) ~ -f Cr ~ Q m

£!0 *;
s e _, (")

~ > 0 ~I . :: z ~ ~ 0-; §Ci) ;a i'iO ~ ~ (ll (II -f m ..,........ l*l Q!.o.. w..i.'f"t. .!,.* L u -.1r1i1.-.*.t j,;t UW"* t. -<lj f . " i _ ,,,..., M Q. _.. l. ...,.~~**- ~ t_ ll1'1"Wf -l I ="*'W\\! ~

  • I...

i\\Udt dlO.......C:: 'It "'(II J~I.; *.. illllt~ <>>N'tUl. n ic1 ** ~LIU.I 9 1 ii 0**1 Ill l f..111 p.....,

      • ""=;

t p, ol lf *U *, . '* ~-..,. I *: s.*;,... ' ~ I.. ""' '

  • lllll.0,11\\; 1111.........

I t '..1

  • 1_,,flll Kllio II f'C JI.,,1' l

to1,l**1 ~ !llllllCll>>'<>* ""611.t tn.... tbU1 t.M. 'i'"&...~!t ltO il ' I , l /'I I I 0 ~ jl 1- ~ l1 CJ

D c B A 8 LOOP A TO COMP. I 7 (T HOT) REACTOR OUTLET TEMPERATURE NARROW RANGE 520 - 620F WIDE RANGE 120 - 920F 6 LOOP 8 TO COMP. I ~-- - --. I I. . I RCA9.3 ~ RCAI0.3 ITJ RC*6A*Tl LOOPA LOOPA

t. T Rt-"7~-TAl CONSOLE CON'O>OLE 0
  • 70~F 520* 620° F

,-*----*--- --~----, I NUCLtAR INSTRUMI:NT AND I I REACTOR PROTECTION S'(STE '1111 I l I>Wii. <:304024"1 I I !'IPS TRIF'INPUTS HI TEMP. f I . l_VARIABLE PRESS./TEMP. j To ciiMi:>ur"ER"r4JT-T"~+l.fo-coMPuTER Th LOOP A 1..-J L.r Tt, LOOP B To RC-148 *FT LOOP'S' Tn CONSOlE 520*,'20"F TO DW6.DS54569 FOR TEIIII!CilMPENSATIOIJ 41 LOOP B FLOW RC~S-7,.L.....!.ll.ccs.-d.TT ~ RCAI0.7 f F1CAI0*8 TO ICS rn IA/ao* TO DW6.0553731 ( FW 13.9) ciJc RNI-<!n RC*S-ci.TS INPUT FOR LOOP A TO S TO ANI>IUNC.

t. To COIJTROL CON50LE6 Tc EXCESSIVE

-IOTO+IO"F b'Tc AlARIII+/-s"f I LOOP 8 TsAT' TH LOOF' A 1 ( 0-3000 )__(120~!1.20) (0-~00)(120*920 J 8 1 A.V~ DIGITAL CONSOLE 520*620°F RC-1~- Tco.~ Wll.l AUTOMATICAL\\.Y SELECT LOOP W!TK GI<EATEST FLOW IF.(.9f.'}'o FLOW IS S.fNSEP TO ICS TO OWG.D553732 (RC7.10) INPUT FOR EITI-IER ROD C.ONT,.OL-OR FW DEMAND NOT£ Ts.o.T MOT 1'0Bf U~ED W"lit-1 RtS HMR < 300°1' NOTE OUTPUT.> FROM PT949, 963 4 TE 960/958 60 THRU SIGNA* CO"'D!TIOW CABINETS 61 1 AI RESPECTIVELY 7 6 5 TO TEMP. SELECTOR LOOP A Tc (WIDE) TO PRtSS RELIEF VALVe --f!-1.. INTERLOCK WR NR WR RCA IO.ZO 4 REJ>.CTOR IWLETTElJIPERJI.T~RE WR 50 G5>0°F NR 520 G20"F !o.IR REI.CTOR IMLET TEMP. \\LOOPB/A MARROW RANGE) PAiCH BOARD LOOP 'N Tc RC*IS-M5 WR REACTOR INLET TEMP (LOOP's' WIDE RANGE) PATCH BOARD LOOP 'B' 'Tc NR TO COlJIP. REACTOR INLET TEMP. \\LOOPB/Il 1\\lAAR(iW RANGEl PATCH BOARD 3 WR fO COMPUTER (SEE NO'Tl: I) >407°F FOR 4th RCP (IF '81 LOOP) NR REACTOR I~LETTf.'MP. (LOOP A{B NARROW RAI.IGEI PATCH BOARD RCA7.26 w Tc RC-58-112 (~I>.RROW) COI.ISDJ.E DWG.NO. REV R SZ0-620°F NOTES: 0554566 1 DESCRIPTION REVISED TO INCORPORATE ECR 13-00280 Rev.O L LOOP B Rc-78-TAI LOOP B Th RC*S*Ta.T I) LOOP A~ B clT CALCULATED BY COMPUTER (Cibeb, C IID87) MANUALLY OPERA'TED SEl..fCTOR SWITCH T AVE COf.ISOLE 520* GZO"F RCA.IS.t5 I RC-7-To.T I ReACTOR AVG.TE'M~. PATJOH80ARD TO'ICS U~IT OUTLET TEMP. PATCI' EIOARD SELECTED Th SELECTEO Tc ~.. ~ **.,_ "'"'"'* r=~::;[ft" UNIT UI>JIT RCA u;.oe d:JC-6*dTf Th Tc I RECORD<R coNsoLt: 520-620 °F UN1i t.T TO ANNUNCIATOR CONSOLE 0-70°F 605' F TO DW6.55:l73* "~ (FW 10.~) RV 5 I 4 I WR Tc DIGITAL so-Gso*F Pci:: RSD'A' ;;a Rso's' TITLE REFERENCES 3 S-SASS SIGNAL VALIDATION SELECTION REFERENCE DW GS: -~ ~ ANALOG LOGIC PART 1 : D 554518 AIIIALOG LOGIC PART 2: D 554569 DIGITAL LClult D ssar:s9 ,Cad File Name : 0554566_RR THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Exelon., Nuclear I Bailey Meter AUXILIARY CONTROL SYSTEM ANALOG LOGIC COOLANT TEMPERATURE LOOP PART #2 I N/R, I I DWG. NO. I SH~ET I RRV 0554566 SCALE: NONE 2 I 1 D c B I A

o c 8 8 7 6 L99v99a 'ON "DMO STEAM GENERATOR LEVEL L LRIOM TO lC$ owe. 0553731 f\\I LEVEL LIN\\IT STEAM GEN_ OUTLET PRE SS

  • PTI 6A SP-6A-PI2 NN! CAB SP14_2 S--...t T.

SP-6A-MS TO COMPUTER SPI6.1 SP-GA-PII COHSOlE 0-1200 fSl3 SP-IO-LS TO ]CS DWG 055315 I

  • D553730 I3TU LIM ITS AND eOtHROl MS-Y~'~ ~ l'\\S-V4'S j

DUPWCATE fOR LOOP 'B' 8 SP-IO-PR (STARTUP) 0-380" HSPS CAB TOGGLE S'oIlltHf5 IN TRAIN A 1 B \\\\~PS CAe 5A5S TQ Ies ow!. 0553731 WW LEVEL LIMIT DUPLICATE FOR LOOP "8" TUR8INE STEAM PRESSURE SP-IO-MS TO Ies OWG_ 0553730 INPUT FOR Ies 'TUR81I'1E HEADER P~eSSURE C~'~OL v IA TlJK~INc. CON'TROL VAI..V 10'<> MS-",;S ~ MS-V4'S 7 0156 LEVEL 0-",40" 5tGNAL CONOIf\\Q\\1 CABINH AlB 6 PCL 5 4 MAIN FEEDWATER FLOW A STEAM GENERATOR LCIiIER OQ';INCOMfR TEMPERATURE 0-600° F ~ STAIIT UP F'E.EDWATeR FLOW A o -IO~ LBS.!HR. 0_-_"'_' __ 12.'" lIOS./I1R-TO PATCH ,BOARD TEl T£2 S~ 3A TO PATCH BOARD TO COMMER SP-7A-FT SP-SA-FTI Prl SA SP-3A-TI SIGNI\\l CONDITION CABmn A B RSDA PCL "A" C,c. "A" RSDA "A" R50B "13" CC \\'B~ cc. "8" RSDA "B" R!;OB SP7.la R5DB VBB SP-7A-FI COIl$OI..I1. 0-10' LSS, I ~R, SP-8A-FI COI\\SO~~ O-"'~IO* LBS/HI<. TO ICS UIIG D5537a I I SP-IIA-PI INPUT FOR FW ER.R.OR bEV"l.oPIoIENT FW VALve TRAIN DIFF. PRESS_ ~ TO Ies

d.

IIA TO COMPUTER DW&D5~~3~73~1 ______ -, DUPLlCATE. FOR LOOP "fI" E.FW FLOW" A" Pel VBC TO COMPo 3 TO COMP. ~ TO (Dill? 2 MAIN FEED'IIATER FLOW 8 r-___ O_-_6_~_IO-':: LBS./HR. d.PrI 88 TO roMP. <!PT2 88 TO COMP. 51A1"T Of' F,,-eDWATEP.. HOW a 0- 10" LBS./HR. d.PT 76 .... --.TO COil1PUTER


l SP-BA-FT2 I

I I I II L. _________ 1 1 __ SP-88-FTI SPS.24 SP-88-m SP-78-FT s SP7_19 SP7.27 10 PATCH BOARD SP-S6-FI CCto.J$O\\..i SP-5-T! CONSOLE O-SOO"F 0-6 ~ 10. lllS'/HR. TO PATCH BOARO TO Ies 1lWG_ D553731 BTU L.IMITS AND FW ~IIIS/MASS CAI..t:ULA'!1lR TURB_ IDR, STEAM TEMP. SP9FR CONSOLE 0-6X106 LBS./HR. TE -1420 (LOOP A) TE-1421 (LOOP B) SP14_19 I----~~-~TO PATCH BOARD (MS-TI-1420)(LOOP A) (MS-TI-1421)(LOOP B) TO COMPo ( DUPL rCATE FOR LOOP "S'! TO Ies L~IlWG~~.~D~5~~~7a~1 --------~r-------------~.; I\\lPUT FOR FW ERROR OEVEI.OPMf.II't

  • MANUALLY OPERATED SELECTOR SWITCH S -SASS SIG>lAL VAlIDATION SELECT lOw REFERENC.S:

DIGITAL LOGIC 0556189 CAD FILE NO.: D554567_RQ I I I I I 0-800 GPM CL D-BOn GPM CC 0- BOO GPM CC o-eoo GPM CC THIS IS A COMPUTER GENERATED DRAWING. DO NOT REVISE IT MANUALLY AUXILIARY SYSTEM AN,~LOG L~!C srr:ONDtlqy Pl ANT REV CH R REVISION 5 4 CUSTOMER: MrTROOflI TTt\\~ CDJS0N CO. PLANT: TeREE MTLf ISLAND CONTRACTING ENG_: GIlB[P,T ASSOCIATES INC. .\\ -2%62 8_M.CO. JOB NO. : 150L CUST. ORDER NO.': 620-0005 \\ -Zo-,~.c, R,\\1 ,DWNGSt.; AILEY METER COMPANY WICKLiffE, OHIO 2 J 0554567 Q CHKO/ APVDflb } ENGR c:~,", o c B A

D c B A 8 PP.2. ~Er..T~B \\IITE'11LOC.'o\\ f'R'2..~o~1oR':. OFF PRZ-LeVEL ( BO* PRZ. lll-f\\1 ALARM SIS '1 PRZ, LO-LO,0,\\.ARK BO' NR (LOW) RCS PR!i.SSURES O*SOOpS13 ~ HI-HI RC:A9.& LO-lO LEVEL' IHTfRLOCI< 7 PRESSURIZER LEV!OL 0-400" TO ANNUNC!ATOR HI +It & L*D-LO 41 J SET PO!IIf I D~4D0 11 1)~100'1~ \\ NORM AU. Y' S57o I (z'o ') 1 6 CC. RSO 0-400' 0-400" TO Atm!JNCIATOR HI ~ lD PR7 ~I ALAR I'\\ ZG~" PR't \\.0 AlAR" "oo" PRESSURIZER WATER TtMPERATURE ~ I 5 TO COMPIJITR 4 Ni>.~ROW RAH8f' RC PRESS 1700-2500 psig 1 m 3A PTI sa m 38 P~~-~A:__l-- 'c' ,~ Gp _L;_ .,._j. j 'i'REACTOR --~ --- 1 d' SYST~~IOII --... I '~. "-"*I I r ----- .------L-I ~,_, I 1!, LOW ALARM ~LERCA(.IS 1 I -- ]. -: _[__j FW il* TO CaMP r--Tl HI & LO ALA: L_Jl__J I I ~0 COI!PVTER V '/it,~" w"m ~ciJ RC-2-Tl CONSOLE o*lOO" F ~ ~m* c) cc I R I I I I

  • 0 CCHI'

"' uco "'" "*') TO ANNUNCIATOR Hl & L0 LD Z055 pSI<) s HI ZZ55 pSI<) LO 2055 p'>l9 s RCAIHH; rRCA~ RCAIOf4=1-, /r. fl f-1RC.-3-PS8 ~- PhSSUK't::. HfATE.R Ci'JNTROL BANKS 4- ~ 5 8ANK 4-C.\\20 -2140 ON OFF BANK 5 2IOS-2125 ON OFF ON-OFF CONTROL TO PRESS. RELIET VALVE IN "AUTO" OR "OFF" NDTT SWITCH AND > 329' F RCS TEMP. RC-RV-2 OPENS @ 2450 psig CLOSES @ 2400 psig TO SPRAY IIALVE Rc-Vl OP!:.N'=- t)Z~i!O~pc.1<7J, CLOi>cS iJ Z.*'OS P"~ IN' P,I.)To' OPiiN TO= 4-0'?,. AU.O'II", = 10'lo SIPR/W FLOW 3 PLF [-:.:-lr _ (PT5\\ PT5 O*SOCps*~ ~ I I I I POR\\1 RELIEF (.RC-R'I-'Z) UIST COO!O RELIEF INST (RC-RV-IA) F\\CDT 8 NOTe: R.C RY-1 B SIMILAR. E.XCEI"T. DPT 929/ DP\\ 923 A>>D TE-3P!O /TE-3AIO I L __ [_ -- _____ J RC-1-LIC TO ""KE-UP VALVE E/P MU-V17 PRZ LtifEL CONTROlLER 7 ALARM 'Ill >3o"F !:, 1 6 ~dNTf'C!. Wki~R LtVt.L C.ABlN.£.1 D l~l ~LAI<M (CM'ROL <t<>o\\-1) SAFETY RELIEF VALVE Ofol-l ALARM 5 RCS-i>IC PR2 HEATERS 5AN~<;S 1,2,23 'F\\Jll ON' Off BI<NK \\ 2135 - Z\\55 BANK.2 2 12;.5 - 2.\\'5 :) 8AI;~ -a 2135

  • 2141 MOOULI\\T!\\olG HEATHS REFERENCES 4

3 TITLE 1 DESCRIPTION REVISED TO INCORPORATE ECR 13-00280 REV.O REACTOR COOLANT PRI'SS, WIOE RAMGE 0-2500 psig ~--------~------~ ~1 \\V i ~ r --J,:_""' j '-"""- :,* -""' 1 clr.iiNEERED SAFEG\\li>.RD I I ACTUATIO~ SYSTEM I I L ___ _ I I I


~b_j SIGMI\\L FPllll TO

~w~*~ ~ }- ESA'> C:Ailme.T I \\t\\TERLO<K FOf< W*lfl ) ~w ""9 DH-V\\ Wii.L 'AUT<>' Cl.o.5E OR \\F Cl.OSE.O CA~r\\OT OP'\\1 ( DK V2 StMllAII. S\\GN/o.L FCi2. RC-FT4*o*A CAB<:) CONSOLE cc 0-2500 PSIG TO AN!IUNCIATOR TO Al.AAM AlA RIII lNTERlDCKtD TI!RU ~5 INTERLOCK wml CF-V!A & Cf-VI!I CF-V1A/1B <S~S NOT ltSSET OPEN AND ) 7!'>D ?$\\'; (LP !} RCS PRESS )1100 p$1~ lHPI) 'S_ 650 psig CF-V1A/1B CLOSED AND RCS PRESS 2: 700 psig ESA~, I!OT BYPMS ( !700 p$*") lHPI) ( 1S<l p5\\"j tLPI) RITIRfoli<:ES' ANAlOS LOGIC PAIIT 2, D55456S ANALOG. LOGlC PART 3: 0554'569 DIGITAL LOGIC 055159

  • ~NUI\\LLY CPE"RATEO SELtCTOR SWITCH

'S -~5S SIGNAL \\ll>.Lltll...i\\0~ SELt.C'HOl4 I Cad File Name : D554568_RR THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY 2 Exelon.. Nuclear I BAILEY lviETER AUXILIARY CONTROL SYSTEM ANALOG LOGIC PRESSURIZER LOOP PART OWG. NO. ISH. 1Rr 0554568 SCALE' NONE I 1 D c B A

D c B A 7 r 6 r------- I ~~TCH {"'l:---1! BOARO... I I I L __________ _ r COOLANT F1.0If-LOCI' A (flOW TUBE BY B & W) n*,,* TEMPERATlllE SIGNAL FROM Re TEM? LOOP Re S'lSTEM OIIG. 0554!566 BOARD I I I 1 I I I, ~TCH { -~--.... 1---- -----'~IV;_=!'t----.J ~ONSOLe. Q -90

  • 10" L6£./III'\\.

RCA15.8 TO ANNUNCIA'TDR A \\.QOP R<:~ fl.OW ~o 62.,

  • 10" L8S.I.. 11.

~ LOOP 1'(, floW H I 1Z.~ ~ 10' lB~./HR. (8 lOOP IS mUITICAl) FLOW TRAN~Ml'n&.R. \\.0(.... 1.D NN \\ CAS TO RC-I2-To.S TO 1711G. D554566 LOW FLOII CONTACT looP A I~PUT FOR. \\.OGIC. TO TRANSF"E'R TQ,"E! c.o.. T"G\\. TO lOOP '!lITH G~E"TES1 FLOIN tB LOOP IS IDIiMTiCAL) 5 i 4 3 COOlANT FlOW LOOP B (FlOl TUBE BY 8 If.. wl 2 o r~--------------------------'---------------------------~, py. 14 'D'RP~ ____________ __ IRIClEAR IIISTRIlMENTATIOM AND REACTDR PROTECTION SYSTEM ~ TO COtI'lITER COOlANT FLOW LOOP A TO 1CS TO_. DSS0701 A LOOP INP"T TO 'BTU LIM1TSIj F'N RATIOIt.lG OM \\O()SS OF p'Cfl' (8 lOOP IS 10 lNlICAI.) OIIG ** EOO40246 ~ TOC~ COOLANT FlOW LOOP 8 K ~ ~B '-:""'--------J,<: "-n_ ----..,:--"" - - --l I, ... } I I TO PATCH BOARD


~

Th '8' TEMPERATlllE SIGNAL FROM Re LOOP RC SySTEM 1lWG. D5154566 s 1---- --------- ----, I I I, I I I f I I 1--_-_------------- I }~~ RC-I4B-FT FLOW T\\tANSMITT£1t LOCATED tlll 1 CAS. TO ICS TO D'I/G. Il5537BI RCA 16.21 TO ANIUlCIATCR CO"NS-OLE 0-90.. 10" 1.6". Ill",. RCAI5.22 RC-149-FI TO RC-12-To.S TO 1l'OG. D554566 (ID'~T'GAL TO \\.OOP ",) LOW FUJII CONTACT WOTE:: ~~ J;~~£Nl'?e~~.l'\\r~,,~. F .... OST CONSERVATIV,," APPfIOAOI FlP5 FLOW IND. O-flO" 10" LBs./~ ~ ANALOG LOGIC PART I. D55456B PART 2: 0554566 DI9lTAL LOGIC: D556I39 S-5.0.S'S SIG~~ V.o.I.IQA1IOH $!L£.CTIOM ~-MAWUA.U.Y OPEU"(tI S.!.LECTb~ !WI'ID\\' CAD FILE, D554569_RK THIS IS A COMPUTER GENERATED DRAWING. DO NOT REVISE IT MANUALLY. c B r-~ ______ ~~ ___ UXW_ p~-------------.U-X=I~Ll~.~RY~~~Tr=M~---------------------i RE~CTOR eOOl~~l~~or~p PAm' 13 A I CIJSlOMER t I£TROI'OlITAft EllISON CO. PlANT: T_r MlLE ISLAND NUCLEAR srATIa.. CONTRACTING ENG.. (J1LB£RT ASSOC. INC. 29062Z SUPERS[I)[S 1l'oC. C5545E9B 8.M.CO. JOB NO. t ISOL CUST. OIIDI!II NO. I 620..0005 ... n I* I 7 - <;; 9 R<.V. DWN S"V )( WlCKUFfE. OHIO

I f~ ~~~ow IS LOOP A \\ ,~ NO Re FLOW LOW \\ PER RCI4B-FS? PER RC 14A-FS? 0554569 OS54569 YES NO RCAD2.1 IS LOOP A Re FLOW LOW YES PER ReI4A*FS? ) 0554569 NO RCA03.'2. (IS RCI2-T S UNIT TA\\l6. YES PB OEPRESSED? ) D554566 NO ReAD 4.2-IS ReIZ-T S YES LOOP A TAVG. PB DEPRESSED? D554566 NO RCAD 5.2-( IS RCIZ-T S \\ YES LOOP e TAVG. PB DEPRESSED? D554566 ~O RCAD6.1 RCAD ~.'3 RCAD 10 4 ISELECT RC7A-T T I ISELECT Re7-T T I ISELECT RC7B*T T I ~~~. SIGNAL SIGNAL 0554566 D554566 I REMOVE SELECTIDN I I REMOVE SELECTION I I REMOVE SELECTIDN I i RCADI.S IS LOOP ~ PUSHBUTTON DEPRESSEO? NO RC~D3.5 IS LOOP B PUSHBUTTON DEPRESSEO? ND RCADS.S IS UNIT ~VERAGE NO I PUSHBUTTON DEPRESSED? o IV v .a:... RCADIS.S CLOSE PRESSURE RELIEr VALVE RC*RV-2 PRESSURIZER LEVEl SELEcnON PRESSURE RELIEf VALVE INTERLOCK RCADIS.3 OPEN PRESSURE RELIEf VALVE RC-RV*2 NO 2450 P~19 I YES NO ~ -I Iw YES RC~016.S I _RE ~~Q~rr ~~-2 VALVE \\ YES NO 'I/lDE RANG() 43'5 pSI':) > LOW SET POINT TO OPEN IN EffECT PER RC3A-PS9? PER RCADI7.2? NO YES' ~......... ,NO G) *

I

'1>1>-

0'"

0;;: R li'- 01'1' c;Q

o?

>>r> /II Z /Il

<1
~

~ .!'IO r (JJ>> "'~ ~ ~ ~- ~./Il !i 'Ilr ~~ <is p-em ~f ~ -< of. ZlJI Q Z/Il 'po Oi O-L//r -:-£. £, ':tb~!7' Po J o ~

j

~~ r 0:- J () I 0 1\\.8'5psl~ \\-n .._,-~- S' 7" -):t.

P:;U i'il ~Z~lP"'~

I

0 ~O;1)!P~g ~

~ ~~F*~-'! fh £,c ~.d~ ;:; z(l:n_.'!1" !' Z.~6 ~ ~ I< 215°F ~8~§~,i ';~~~~ .~ ~v> ~'i a~~~g "510~" '~In ~ ~ i Pt_>::O~ -<(O:I... :e ~a~~~ l~ =g~ iii Z::!l!>... 8 *<~:r 0"'-1'1 J:I'IO~'1I ~H' ~ ~_OZ'1l . ~ ~ ~ ~ %... ::o~ 2:~~ ~~§~

u:~~

~-OJ: o(h~ ~ 1'1-10:0 zO"'n "-0.... 0 i:F'~ 6gz~ cfJ)0-e lAo

0.

r~~f~~~ ~ ~O l(o 0= Z . I ~.. :.:0:;;: ~ )<. 6) il~1 g~ 0 t>:tri t I" en .~ i~ ~ ~. 5= 11IlH. m=:a """'en nil Z~~ -(. o r;:;, o n ~. r~..,

t>
i
  • ro -0 mg~

L~ jj)- c ~jj\\- G'l:<.;;'-":;J _lfl r 1)-' ~"'.a = r,:j m1t: =<>1 0lJ>)> :ll);>:lJ rllZZ);>'-{ ~~ o ~ t\\~lJm'-t. (.J1 ~ ~:t>Z2~o~ ~ (.J1

-' (flclJl m!i\\

~:3 ~ ~ (/\\()o r;~ ~ o o. Z. fl1 LN m () m 0 s: ~ U)

0 j;:>> ('l 0

~ ;riJ3 9 'Il ~ (J) IJI ~- '-t I ~ z~ !'j ()- -~ ~.~ ~ ~.~ ~,~ ~ 0 ~ x

00

0.

(II w NO REACTOR Tave CALIBRATING INTEGRAL RC 9.12 OPERATION YES RC08.2 RCD2.3 RUN RC9.12 UNTIL OUTPUT OF RC12.12 EQUALS OUTPUT OF RC15.13. NO

  • THIS LOGIC IS PART OF ROO COH!ROL SYSTEM fli!NISHEO BY AREVA BLOCK CAL.li!RATING INTEGRAl RC9.12 a~5~g

~~~ :o,.!~

1~

~*~i!:E .. a~.. z a=lilz: nH~i! ~~~g-~ IU* 8

c:;!!l~'

c ~ l=i.~: iii'=O ~asj! ~*~; !lu lgo!ll ! "'8 r- !i~!'il: Ul~.* ~o(g ITl::o::o

E~o ITI-::0

<Z- _G)G) o)>:z CiJ)> cn"'tlr

o::t!<

(TlOITI

5~z

~fi;g 0

0

~ L----, 1--:::...........,......, ~§~8 8=~6 II ii.. 0

  • it;

.... g.... "' gz ~.. ~GI;ili

.h~

- ** r;; p l:'ljs;:!:; ,...llii5l:: 01 ~~ ~~ l;!n O:rJO "~ ~U)EJ s~~ ,.,.~ ~ ~~~ 0 ()l ()l Q] "-J ()l ~~ n::; ~q "'li~~~ ~ns!i 12i"' ';l ~;;; -A z ~ p 0 M ~ ~ I ** ~ ii ~ ~~~ ~ ~ '-"~ "'"' ~~ ~ c_ I~~~ c.n~ o r-- rrloo 56~ ~~~::u ~~~ -o:P>

j::E;;o~ li fTl-um

=~ 2 ~8~

j~~

~s, ~~~" ~"'\\, -In ~ A~r!". ZQC.... ~ ~ ~g:~

~

)> F~ o<J> o1 0 0 J> z 0 INSERT- \\IITHORAW SIGNAL TO CRD ROO CONTROL. NO RCDII.3 IS* NEUTRON ERROR (+.91.PER RC 19.12 0:1 AVERAGE TEMP. CORRECTION TO f.II. OPERATION NO RCD RCDI1.5 @I RCD 14.6 () 0

8 7 6 L...~-------~~--~~ r FOR ORIGINAL VENDOR DRAWING APPROVALS SEE PREVIOUS REVISIONS ~ ~i! t R *-' 3 0 c B A 2

8 7 6 5 4 3 2 D [ NOT IMPORTANT TO SAFETY AS-BUilT DRAWiNG E ( x t- ~ ~ I AP."D' JUN 21) 1974 IvJb<; R E eEl V E 0 ~I/.~ u, E. &.,;. INC. ~ \\.- ENGINEERING ~ DEPARTMll:N:t: \\\\) c.. it!> ~'W'FB AlliIN' NO JEV D55018.91 f ~ ~ g ~ ~ ~ ~ ~ ~ ~ ~ '.HI!> oJlA\\\\'I"C. is fon GENERAL INFORMATION AND REFERENCE ONLY "nIl I,,,. not htt-II "lUr"**.,d 10 tnt m"n\\,lI.~\\I'U."lb GAl AP1.itO\\",..L (If CO~Ud.lit.:TS ~~.;;;.".:::~:::Jl~~ WICKLIfF., OHIO Ann AUJ.IltARy sysn,.... olr-ITA L LOCIC SHONQIl,R'Y PLAtH CUSTOMER: >f:1"oPOLrr," [DISON CD. PLANT: JI~R([ ).1Il[ ISLAPIO t~UCL(AR ST.HIOII 'CONTRACTING ENG.: CIL&RT ASSOCIAT[S, ItJt. 001 B.M.CO. JOB NO,: I:<lL CUST. ORDER NO.: A'-.'V2L."-lXC!' 302 02 BABCOCK & WILCOX DRAWING NUMBER 62().()OOS 2 REV lo,ur ~--------- ~~_/// /' ~:! \\ I \\r ~ ~~-a' ~ ~",~lJ) '~ ~,~~ 'Io-gl'-; )i: ~ 0 8 z ~. 12 2 I ~ ~'" 3§.; ';; :x I- ~ } s::::) u....

ij

~~o..0 S LL 0 THIS DRAWING IS THE PROPERTY OF BAILEY METER COMPANY.rn I~._-. ~ NEITHER THE

DRAWING, NOR REPRODUCTIONS OF IT, N O R.

c.. =.rji:%-,l.~ R lJ ...) lC ~ BAILEY METER COMPANY ~;~~~~~I~~ ::~~~~ ~=~~ ~TH:~HT~ ~~ c:.:~;NB:~N~~:I;:SS tI3 "~I 6-j' 1/~ /I(/I~ ~<, 71J" TO SAlLEY METER COMPANY. A ~..: ali: ,0 ( I I 00 ' IQ =iXJ 0.- Vlii:

9 l\\J"VI CI z

c..1- ) I g QQ,. I I~ t; '0 ~ ~4: ( z I- ~. Il.- 1Il,e; 0. l-- ~ Z e;: t-' .3 II! ,t 10' ooUl 0.00 V)C>. ,\\Il N I-~ LLt I ~~ Of ,._~C:l ) I 1-'::; I I ~o. ~~ I I I 81 riJOCi' /.. '" <<<t Q,. 0-0 00 g~ ~~ .. ~~ Ill: 0 ~ ~~~ 2 ~ 0 ~2'-' ~ c.:~~ ~ g (( 9 Q

J 2

d. I "0"'" I: II"-U". 8 7 6 5 4 3 2

~ CD n o 0. Ut I>> e..t ~ D ULD (;) (;) n ll.D38.3 at r,.,rCATE fl.C. PlMP RlIt'eAc.K 1.0.037.3 INOICATE r.w. _ R"",a.CK UlD40.3 ....039.3 INDICATe R.C. FlQJ R\\leACK r,.,rCAT~ ...e..VMMETRtc ROD -~ UI.02!>*2 mAHSF(R....7.3 TO ....5.1 ULC27.2 ~RUL16.11 TO 1JL16.12 F'OR MAX MAN RATE OF 511, PER MIN. RErERE..cE "rlIi§.: UNIT LOAD OEMAND"O£V[L0PMQ4r AMALOO l.~IC 0553129 OMIT lOAD DtMoUl) ()(YEl~l DIGITAl L.CCo.It P1R1' I D553734 lJL023.1 ~ GJ f

0 ~~~

~()i;~. ~

f'-n C

~ rr1 .~I n ,':2 ~ N~ ,~> ~~;: Z;:c AJ. ~ ~~ (;) TRA.NS.fE~ lJl.*. ~ TO UL5.1 ilI'IU Mil I~;i.il ill'- Ii Ii ~~hl 1:1' .<1 ...1 tli ~I i ~i lt.~i ~!! Jt. ~ln,

o>!
'

S!8~ f4~g:

~~

,,"'\\0 Zc>c> c:'" "z 0<"8 §z" 'I 01) 0. w ~i il~1 11 D.- J "1 J= ~ 1 ~ II

~.~ ~

CI "'i~ ~ t i ~I: ~~6 o 0 ... ~ ~z (; Fo pi ,.g - t: ~ ~ ~J: 8

f I!

f:J ~,,1> iii~ 1;,5 (]I >J IH dS ~ ~ l "5 _I~ ~ J ~ ~ Y: ~ -.J m t r. 1 G) ~ ~. '-I II ~ V* &\\.~ i .. 14 ~ Ul

1 l, ~ .1 -~ .f 1 ..t 0..-",'.,- ~ I

j
-"-1 v

~ t: 'i., f* "_I; / .". ::j ~'-f 4, ~ ~. <-(z25~i\\D ../A~~ . _ '1~1 c:£;:v-/r"'9lNft?8,vr .':,i ,.~_ _ -_1-_....~~ ~.ORJGJNAL F---

I

~ '& W~~7ff;.~ sue. I ~ d7 r. ~:.?-:. >-.Mh.'£S _2 -~- $ue.'.... I-.2.....t----=;----T2:>.S '!c'-, 1'7'"...--c*......,....'OP / 0 ~~ ~ -<"-- /)~~ ll2~vIS/cvJ -BEST AVAlLABLE PRiNT C"ONTACT EO & CC FOR ORIGINAL 8M CARD \\ I .* /NOlc/rr£~ rE I; E/,,/CL,o".:S4J..R;s ~A? Bt:....J.:t:..,,/..v45 41/,,, pr p....Q::,V/OE'.o

FO~ 8.0 T"h" CAJP.s.

/& 9.,/1' ..=rT;.J,.""V',£ F SS 7.0 ~ <.J.s'FtJ:)~ .,.....s""e'.:!t L; /~h:;;h'T- -..$So "T" L.//T"n'CVT EdC&.~.s<.J,e£.s.. f I.. r/3"lHDA!ITO,e RING I~I (/Vur -Silo!'VA/) / ..sue,3 *'r?\\ .s~L3.2~I ~,~3 ~ /9L::>6~ \\. /7: 97 \\ .:;~~I \\ f J --""LJ:-~ I r-r I _,c::>-pg~/"'~...... ___ .s"Gl83 *' "-.... .:L.25" 17.75 .....-1 AUG 1ll*1T1. mo TIIlV (lH 34/C

a
"p Ie.342 E

/2cp ID 343E' 344C / SUPERSEDED DATE ~----~---~~-_._-~-]~~ DATE _3'- :3/- 70 SPECIFICATION NO. C::-:-.2~~ ~- A / - Cb -7/ I::3PE I::?::::'P /H 2:"?E Rep 18 23C-£

-.37£

..... L Of"'- IN.MeH O....oT ** CH i---i .. I I I ,i.. J I I I METROPO IAN 'EDlSON COMPANY I I I THIIEE MILE IS 0 NJ~LE,IIiIl ";T"'T'ON IJNIT NO. 1 I I I !&tAPPROVED CHE~KING IS ONL'I" FOR GEN* EHII~OESICN liND a:=NERAL I un.IE SIONo: ~ET FOHTH IN ~'I.Z:-<:.~-. L l"B..,I.PPRO.lIa.:.*,s..CUli,v\\Cl Lll1CU/'i[NlS.A.1..W. -r-: i ". I NOTED DOE NOT i'l"LlEvo ';CNTn...e-LL?/\\//"/l'//l./'/rJ£N7 I ~ TuwF;>.O". HI'> UBLlOl\\rHJ;j AS I I . _.---.- +-- I : ~ ~~~~~~~F~jJle. U.r.IL. WUMK.'",ANSHlfo-I I I OIL~EAT ASSOCIAT S. IN~. By.I<~JA..~ I I ITEM No._Fl-3\\ o Tt3.~I/':":7/ ___~~ ~,t{.J/~..*)~foT8A.T1I2AL.. I I - -'I - - .._._.- J J "\\:-

3

/ ) d,4.oo 3'-/';:;;;( & 4J, 8.3 50_ 'k..s~! ~~ ':=;-p ON /'71,25 !!:.5o ~ p,/;9. s.c.*. "coR E"vc~OS.:....JR.s- /Y/C>LJA..JT/Nc; ....OT.* 1'-:1,Ltk'K

    • OTH.... W** 4l-..... c.....r.o

"...e.....,..'e.1'...,.eo... T_.~IIt_ "_MiD"',, AL'" _U",1I8 loLL Tl4"M. C~.... 0"' ** '....0. '{;Y. ---\\~' I .......\\\\, I 4'-~--------~~c \\~ I / I \\ ~ \\)t 1 / \\ ."\\, I / ' / e~ I. .". ~ ,/ /"'-.. '0., I ' 8/1-1 EL-3 PF..AIETRHTJON HAMEI6'....<""V P:"v / --e....-9/--jc:>..-<..-J 1'.. /.'.., '. "\\ I', I' 0 4-~O(3)Eo/..s~ "":,,,,,./,/0. 87 p'~.8.C. Fe;.R.

C~..LPLE S;Y,/ELJ;)

COA/A-'L=-C7/0...v J /.8-/2 -r'HP5. FOR 8.u..,e;"Vp y

Y"'=-019 I~i Rl'
" Zr STup c"c:::::>....v....vcoCTc>R r:--J\\

l rOR CUSTOMER.:J s:tJtY1CI-J (/l/3L£ viA LlJ:::'. I ..---..-+ /,-- -_.--"~-- /~\\-+'/' ;, l D.C .It ~"'IoC., ********* '.. o ~~:~"_'.~'.~._. ~_~_ ~ I ";. ~ ~.

---T---....--;----r--,....

J \\.- POlIN '\\rESTINGHOUSE ELECTRIC CORPORATION ELECTRONIC TUBE otVISIOH SPEOFICATIONS & STNIlARDS DEPT. 'ElM4RA, N. Y. 3/8z f' r-. t ONT. t-rI 1II lt}}