LES-19-034-NRC FEB 2 7 2019 ATTN: Document Control Desk Director Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Louisiana Energy Services, LLC NRC Docket No. 70-3103
Subject:
Semi-Annual Radiological Effluent Release Report for July 1, 2018 through December 31, 2018 Pursuant to 10 CFR 70.59, Louisiana Energy Services, LLC, also dba URENCO USA, herewith submits the subject report. Enclosure 1 specifies the quantities released of licensed principal radionuclides in liquid or gaseous form, to uncontrolled areas.
Should there be any questions concerning this submittal, please contact Rick Medina, Acting Licensing and Performance Assessment Manager, at 575.394.5846.
Respectfully, Ste en Cowne Chief Nuclear Officer and Compliance Manager
Enclosure:
- 1. Semi-Annual Radiological Effluent Release Report for July 1, 2018 through December 31, 2018 LES,PO Box 1789, Eunice, New Mexico 88231,USA T: +1 575 394 4646 F: +1 575 394 4545 W: www.urenco.com/LES I
/
I
\\
/
/
I
LES-19-034-NRC ENCLOSURE 1 Semi-Annual Radiological Effluent Release Report for July 1, 2018 through December 31, 2018
URENCO USA: Report of Radioactivity in Effluents: Liquid & Air: July 2018 - December 2018 There were no releases to the public during the reporting period that exceeded regulatory requirements.
Detected isotopic uranium activities were comparable to pre-operational activities. No dose assessment was performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points were acceptable. The potential maximum doses directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentrations.
In liquid effluent, the concentrations of isotopic uranium was either below the Minimum Detectable Concentration (MDC) or less that 10% of values listed in 10 CFR 20, Appendix B, Table 3, "Releases to Sewers" (Table 1-1).
In gaseous effluent, the gross uranium activity was either below the Minimum Detectable Activity (MDA) or less than 10% of values listed in 10 CFR 20, Appendix B, Table 2, "Effluent Concentrations - Class D Air" for U234, U235, and U238.
The concentrations of isotopic uranium in gaseous effluent was either below the Minimum Detectable Concentration (MDC) or less that 10% of values listed in 1 O CFR 20.1301, 10 CFR 20.1302, and 10 CFR 20.1101 ( d}, as described in NRC Regulatory Guide 4.20 "Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors" dated December 1996.
LIST OF TABLES Table No.
1-1 1-2 1-3 1-4 1-5 1-6 1-7 Title Lift Station 1 Wastewater Effluent - Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1001 (SBM 1001) Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA 1 & 1001-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1003 (SBM 1003) Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA1 & 1003-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1005 (SBM 1005) Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1 MA1 & 1005-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA1 & 1100-562-1 MA2 - Gross Alpha &
Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA 1 & 1100-562-2MA2 - Gross Alpha &
Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF) Exhaust Filtration System Gaseous Effluent - 1300-562-1 MA1 Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018
@ENCOUSA
TABLE 1-1 Lift Station 1 Wastewater Effluent - Radionuclides, Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico
-irl(it '"':;.,>:},~lWJIJ;,l~~tWi~~it~~,,~~Qi~cN~~Miirs9 --*
Lift Station 1 Wastewater Effluent-Radionuclides Total Counting Quantity
% 9fTable 3.of AppendixB Radionuclide Sample Date Sample Period Time Results Uncertainty Total Flow*
Released to 10 CFR 20 Values-(Datemme)
,(days)
(µCi/ml) fµCi/mL)
(gallons/day)
(Ci)
Monthly Average Release*
to Sewers Lift Station 1 - July* December 2018 Uranium - 233/234 2.10E-10 5.00E-11 13,000 Result Below LLD Result Below LLD Uranium - 235/236 10/8/2018 9:20 07/01/18 -12/31/18 183 O.OOE+OO O.OOE+OO 13,000 Result Below LLD Result Below LLD Uranium - 238 2.70E-10 5.00E-11 13,000 Result Below LLD Result Below LLD Lift Station 1 Duplicate
- July - December 2018 Uranium - 233/234 1.40E-10
- fooE-11 13,000 Result Below LLD Result Below LLD Uranium - 235/236 10/8/2018 9:25 07/01/18 -12/31/18 183 O.OOE+OO O.OOE+OO 13,000 Result Below LLD Result Below LLD Uranium - 238 9.00E-11 3.00E-11 13,000 Result Below LLD Result Below LLD Notes:
- 1. *=Table 3.4-4 "Anticipated Normal Plant Water Consumption" from the Environmental Report, Rev. 19, lists 'Total Personnel Water Use" as approximately 13,000 gallons per day.
- 2. µCi/ml= microCuries per milliliter.
- 3. Radionuclides analyzed using method EICHROM AC01 by Cardinal Laboratories of Hobbs, NM (subcontracted to Radiation Safety Engineering of Chandler, AZ).
- 4. Quantity released is calculated if the result equals or exceeds the LLD. Facility-required lower level of detection (LLD) is 3.0E-9 uCi/mL.
TABLE 1-2 Separations Building Module-1001 (SSM 1001 ): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA 1 & 1001-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico.
Sample Gross MDA/
Inst. Unc.
Total Flow Quantity
% ofTable2 Sample ID Sample Period Analyte Result MDC Released Appendix B Date
µCi/ml
µCi/ml
µCi/ml m3 Ci 10CFR20 1001-562-1MA1 10015621MA1 070318 8/1/18 7/3/18-8/1/18 6.25E-17 1.67E-16 6.31E-08 4.39E+05
<MDA
<MDA 10015621MA1 080118 9/3/18 8/1/18 - 9/3/18 5.44E-17 1.46E-16 6.31E-08 5.20E+05
<MDA
<MDA 10015621MA1 090418 10/1/18 9/3/18 - 10/1/18 Gross O.OOE+OO 1.85E-16 O.OOE+OO 4.10E+05
<MDA
<MDA 10015621MA1100118 11/2/18 10/1 /18-11 /2/18 Alpha
-2.17E-18 1.54E-16 6.31E-08 4.82E+05
<MDA
<MDA 10015621MA1 110218 12/3/18 11/2/18-12/3/18 1.14E-17 1.55E-17 8'.56E-08 5.01E+05
<MDA
<MDA 10015621MA1 120318 1/3/19 12/3/18 - 1/3/19 6.36E-17 1.67E-16 6.31E-08 5.04E+05
<MDA
<MDA 10015621MA1 070318 8/1/18 7/3/18 - 8/1/18 6.03E-15 3.47E-15 1.44E-06 4.39E+05 2.65E-09 0.201%
10015621MA1 080118 9/3/18 8/1/18 - 9/3/18 4.53E-15 3.02E-15.
1.38E-06 5.20E+05 2.35E-09 0.151%
10015621MA1 090418 10/1/18 9/3/18 -10/1/18 Gross 2.76E-15 3.83E-15 1.15E-06 4.10E+05
<MDA
<MDA 10015621MA1100118 11/2/18 10/1/18-11/2/18 Beta 6.15E-15 3.07E-15 1.62E-06 4.82E+05 2.96E-09 0.205%
10015621MA1110218 12/3/18 11/2/18-12/3/18 6.16E-16 3.10E-16 1.49E-06 5.01E+05 3.08E-10 0.021%
10015621MA1 120318 1/3/19 12/3/18 - 1/3/19 4.98E-15 3.35E-15 1.35E-06 5.04E+05 2.51E-09 0.166%
1001-562-1 MA2 10015621MA2 070318A 8/1/18 6/1/18 - 8/1/18 1.92E-16 2.58E-16 9.01E-08 9.54E+05
<MDA
<MDA 10015621MA2 080118 9/3/18 8/1 /18 - 9/3/18 1.48E-16 1.99E-16 9.01E-08 5.38E+05
<MDA
<MDA, 10015621MA2 090418 10/1/18 9/3/18-10/1/18 Gross 6.31E-18 1.69E-17 6.31E-08 4.31E+05
<MDA
<MDA 10015621MA2100118 11/2/18 10/1/18-11/2/18 Alpha O.OOE+OO 1.41E-16 O.OOE+OO 5.04E+05
<MDA
<MDA 10015621MA2110218 12/3/18 11 /2/18-12/3/18 O.OOE+OO 1.41E-16 O.OOE+OO 5.14E+05
<MDA
<MDA 10015621MA2 120318 1/3/19 12/3/18 - 1/3/19 1.04E-16 1.42E-16 8.56E-08 5.17E+05
<MDA
<MDA 10015621MA2 070318A 8/1/18 6/1/18-8/1/18 5.76E-15 5.34E-15 1.26E-06 9.54E+05 5.49E-09 0.192%
10015621MA2 080118 9/3/18 8/1/18 - 9/3/18 6.67E-15 4.12E-15 1.41E-06 5.38E+05 3.59E-09 0.222%
10015621MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 3.99E-16 3.50E-16 1.27E-06 4.31.E+05 1.72E-10 0.013%
10015621MA2100118 11/2/18 10/1/18-11/2/18 Beta 5.38E-15 2.81E-15 1.47E-06 5.04E+05 2.71E-09 0.179%
10015621 MA2 110218 12/3/18 11/2/18-12/3/18 4.39E-15 2.81E-15 1.37E-06 5.14E+05 2.26E-09 0.146%
10015621MA2120318 1/3/18 12/3/18 - 1/3/19 4.96E-15 2.84E-15 1.49E-06 5.17E+05 2.56E-09 0.165%
Quantity
% ofTable2 Radionuclide Sample Sample Period Result 2cr TPU 1cr TPU MDC Total Flow Released Appendix B (Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Ci 10CFR20 1001-562-1MA1 U-233/234 1.67E-16 8.83E-17 8.91E-17 6.60E-17 0.00 0.01%
U-235/236 3 Qtr.
10/1/18 7/3/18-10/1/18 7.92E-17 6.59E-17 6.61E-17 5.67E-17 1.37E+06 0.00 0.00%
U-238 1.88E-16 9.34E-17 9.43E-17 6.57E-17 0.00 0.01%
U-233/234 2.68E-17 1.63E-17 1.64E-17 1.60E-17 1.49E+06 0.00 0.00%
U-235/236 4 Qtr.
1/3/19 10/1/18-1/3/19 2.59E-17 1.78E-17 1.79E-17 1.84E-17 0.00 0.00%
U-238 3.03E-17 1.74E-17 1.75E-17 1.69E-17 0.00 0.00%
1001-562-1MA2 U-233/234 1.78E-17 1.44E-17 1.45E-17 1.61E-17 0.00 0.00%
3 Qtr.
10/1/18 6/1/18-10/1/18 1.51E-17 1.92E+06 U-235/236 1.78E-17 1.53E-17 1.53E-17 0.00 0.00%
U-238 3.18E-17 1.83E-17 1.84E-17 1.34E-17 0.00 0.00%
U-233/234 1.84E-16 7.38E-17 7.49E-17 4.22E-17 0.00 0.01%
4 Qtr.
1/3/19 10/1/18-1/3/19 5.50E-17 4.57E-17 4.59E-17 4.91E-17 1.53E+06 U-235/236 0.00 0.00%
U-238 7.13E-17 4.64E-17 4.66E-17 4.20E-17 0.00 0.00%
Notes:
A. 10015621 MA2 070318, filter was put on 6/1/18 and removed 8/1/18. Monitor out ofoperation on 6/10/18 due to faulty pump. Monitor in operation on 7/19/18. Filter left on for duration.
@~ENCOUSA C
TABLE 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA1 &
1003-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 UREN CO USA Lea County, New Mexico Sample Gross Sample ID Sample Period Analyte Result Date
µCi/ml 1003-562-1 MA1 10035621MA1 070318 08/01/18 7/3/18 - 8/1/18
-3.33E-01 10035621MA1 080118A 11/02/18 8/1/18-11/2/18 Gross 6.20E-17 Alpha 10035621MA11102188 1/03/18 11/2/18-1/3/19 2.35E-17 10035621MA1 070318 08/01/18 7/3/18 - 8/1/18 4.33E-15 10035621 MA 1 080118A 11/02/18 8/1/18-11/2/18 Gross 1.30E-15 Beta 10035621MA11102188 1/03/18 11/2/18 - 1/3/19 1.37E-15 1003-562-1 MA2 10035621MA2 070318 08/01/18 7/3/18-8/1/18 Gross
-8.24E-18 10035621MA2 080118c 08/16/18 8/1/18 - 8/16/18 Alpha O.OOE+OO 10035621MA2 070318 08/01/18 7/3/18 - 8/1/18 Gross 2.62E-15 10035621MA2 080118c 08/16/18 8/1/18-8/16/18 Beta 6.96E-15 Radionuclide Sample Result 2crTPU
. Sample Period (Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml) 1003-562-1 MA1 U-233/234
. 8.69E-17 4.61E-17 U-235/236 3 Qtr.
11/2/2018 7/3/18-11/2/18 6.86E-17 4.24E-17 U-238 4.70E-17. 3.29E-17 U-233/234 1.08E-16 6.36E-17 U-235/236 4Qtr.
1/3/2019 11/2/18-1/3/19 7.40E-17 5.98E-17 U-238 1.39E-16 7.35E-17 1003-562-1MA2 U-233/234 2.74E-16 1.19E-16 U-235/236 3 Qtr.
8/16/18 8/1 /18-8/16/18 7.32E-17 6.70E-17 U-238 1.96E-16 1.01E-16 Notes:
A.
B.
C.
10035621MA1 080118, filter was put on 8/1/18 and removed 11/2/18.
10035621 MA1 110218, filter was put on 11/2/18 and removed 1/3/19.
Redundant monitor out of operation on 8/15/18 due to faulty pump.
MDA/*
Inst. Unc.
Total Flow Quantity MDC Released
µCi/ml
µCi/ml m3 Ci 1.34E-16 6.31E-08 4.63E+05
<MDA 4.23E-17 1.22E-07 1.48E+06 9.15E-11 6.17E-17 6.31E-08 1.05E+06
<MDA 2.78E-15 1.68E-06 4.63E+05 2.00E~09 8.75E-16 1.37E-06 1.48E+06 1.91E-09 1.23E-15 1.32E-06 1.05E+06 1.43E-09 1.29E-16 9.01E-08 4.93E+05
<MDA 2.67E-16 O.OOE+OO 2.48E+05
<MDA 2.67E-15 1.64E-06 4.93E+05
<MDA 5.52E-15 1.31E-06 2.48E+05 1.73E-09 1crTPU MDC Total Flow Quantity Released
µCi/ml
(µCi/ml) m3 Ci 4.65E-17 4.70E-17 1.94E+06 0.00 4.27E-17 3.68E-17 0.00 3.31E-17 3.53E-17 0.00 6.41E-17 4.42E-17 1.05E+06 0.00 6.01E-17 5.98E-17 0.00 7.42E-17 5.51E-17 0.00 1.20E-16 6.93E-17 0.00 1.39E+06 6.72E-17 6.33E-17 0.00 1.02E-16 7.34E-17 0.00
% of Table 2 Appendix B 10CFR 20
<MDA 0.002%
<MDA 0.144%
0.043%
0.046%
<MDA
<MDA
<MDA 0.232%
% of Table 2 App/;lndix.B 10CFR 20 0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.01%
0.00%
0.01%
TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1 MA 1 &
1005-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico
- Sample Gross MDA/
Inst. Unc.
Total Flow Quantity Sample ID
. Sample Period Analyte Result MDC Released Date
µCi/ml
- µCi/ml
µCi/ml m3 Ci 1005-562-1MA1 10055621MA1 070318 8/1/18 7/3/18 - 8/1/18 O.OOE+OO 1.71E-16 O.OOE+OO 8.28E+05
<MDA 10055621MA1 080118 9/3/18 8/1/18 - 9/3/18 1.11E-16 1.48E-16 9.01E-08 9.46E+05
<MDA 10055621MA1 090418 10/1/18 9/3/18 - 10/1/18 Gross 6.84E-17 1.83E-16 6.31E-08 7.79E+05
<MDA 10055621MA1100118 11/2/18 10/1/18-11/2/18 Alpha 5.79E-17 1.52E-16 6.31E-08 9.27E+05
<MDA 10055621MA1110218 12/3/18 11 /2/18-12/3/18 1.17E-16 1.60E-16 8.56E-08 8.97E+05
<MDA 10055621MA1120318 1/3/19 12/3/18 - 1/3/19
-6.19E-17 1.63E-16 2.05E-10 8.95E+05
<MDA 10055621MA1 070318 8/1/18 7/3/18 - 8/1/18 5.10E-15 3.54E-15 1.36E-06 8.28E+05 4.22E-09 10055621MA1 080118 9/3/18 8/1/18 - 9/3/18 2.95E-15 3.07E-15 1.23E-06 9.46E+05
<MDA 10055621MA1 090418 10/1/18 9/3/18 - 10/1/18 Gross 4.78E-15 3.79E-15 1.31E-06 7.79E+05 3,72E-09 10055621MA1100118 11/2/18 10/1/18-11/2/18 Beta 6.05E-15 3.05E-15 1.49E-06 9.27E+05 5.60E-09 10055621 MA1 110218 12/3/18 11/2/18-12/3/18 4.53E-15 3.19E-15 1.33E-06 8.97E+05 4.06E-09 10055621MA1120318 1/3/19 12/3/18 -1/3/19 5.35E-15 3.25E-15 1.53E-06 8.95E+05 4.79E-09 1005-562-1 MA2 10055621MA2 070318 8/1/18 7/3/18 - 8/1/18 1.33E-16 1.78E-16 9.01E-08 8.44E+05
<MDA 10055621MA2 080118 9/3/18 8/1/18-9/3/18 O.OOE+OO 1.54E-16 O.OOE+OO 9.88E+05
<MDA 10055621MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 2.82E-16 1.92E-16 1.26E-07 7.93E+05 2.24E-10 10055621MA2100118 11/2/18 10/1/18-11/2/18 Alpha 1.78E-16 1.60E-16 1.08E-07 9.35E+05 1.66E-10 10055621MA2110218 12/3/18 11 /2/18-12/3/18 O.OOE+OO 1.63E-16 O.OOE+OO 9.13E+05
<MDA 10055621MA2 120318 1/3/19 12/3/18 - 1/3/19 6.37E-17 1.68E-16 6.31E-08 8.97E+05
<MDA 10055621MA2 070318 8/1/18 7/3/18 - 8/1/18 7.52E-15 3.68E-15 1.51E-06 8.44E+05 6.34E-09 10055621MA2 080118 9/3/18 8/1 /18 - 9/3/1.8 3.63E-15 3.18E-15 1.27E-06 9.88E+05 3.59E-09 10055621MA2 090418 10/1/18 9/3/18 - 10/1/18
- Gross 4.06E-15 3.98E-15 1.24E-06 7.93E+05 3.22E-09 10055621MA2100118 11/2/18 10/1/18-11/2/18 Beta 2.49E-15 3.19E-15 1.13E-06 9.35E+05
<MDA 10055621 MA2 110218 12/3/18 11 /2/18-12/3/18 7.62E-15 3.25E-15 1.58E-06 9.13E+05 6.96E-09 10055621MA2 120318 1/3/19 12/3/18 - 1/3/19 7.61 E-15 3.35E-15 1.56E-06 8.97E+05 6.83E-09 Radionuclide Sample Result 2crTPU
. 1.crTPU MDC Total Flow Quantity Sample Period Released (Isotopic Ur~mium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
. (µCi/ml) m3 Ci 1005-562*1 MA1
.U-233/234 2.18E-16 9.35E-17 9.48E-17 5.09E-17 2.55E+06 0.00
.U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 7.18E-17 6.24E-17 6.26E-17 7.18E-17 0.00 U-238 1.24E-16 6.93E-17 6.99E-17 4.03E-17 0.00 U-233/234 2.27E-16 8.80E-17 8.95E-17 5.10E-10 2.72E+06
<MDC U-235/236 4Qtr.
1/3/2019 10/1/18-1/3/19 1.10E-16 6.85E-17 6.90E-17 5.99E-17 0.00 U-238 1.60E-16 7.21E-17 7.30E-17 3.37E-17 4.35E-10 1005-562-1 MA2 U-233/234 9.46E-17 7.80E-17 7.83E-17 9.52E-17
<MDC U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18
- 3.31E-17 3.31E-17 9.02E-17 2.62E+06 5.12E-18
<MDC U-238 1.12E-16 7.70E-17 7.74E-17 6.17E-17 0.00 U-233/234 1.58E-16 7.99E-17 8.07E-17 5.46E-17 4.34E-10 U-235/236
- 4 Qtr.
1/3/2019 10/1/18-1/3/19 8.16E-17 6.25E-17 6.28E-17 4.99E-17 2.75E+06 0.00 U-238 2.03E-16 9.06E-17 9.18E-17 5.78E-17 5.57E-10
@~ENCOUSA
% ofTable2*
Appendix B 10CFR 20
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA 0.170%
<MDA 0.159%
0.202%
0.151%
0.178%
<MDA
<MDA 0.009%
0.006%
<MDA
<MDA 0.251%
0.121%
0.135%
<MDA 0.254%
0.254%
% ofTable2 Appendix B 10CFR 20 0.01%
0.00%
0.00%
<MDC 0.00%
0.005%
<MDC
<MDC 0.00%
0.005%
0.00%
0.007%
TABLE 1-5 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA 1 &
1100-562-1 MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Samgle ID 1100-562-1MA1 11005621MA1 0703.18 11005621MA1 080118 11005621MA1 090418 11005621MA1100118 11005621MA1110218 11005621MA1120318 11005621MA1 070318 11005621MA1 080118 11005621MA1090418 11005621MA1100118 11005621MA1 110218 11005621MA1120318 1100-562-1 MA2 11005621MA2 070318 11005621MA2 080.118 11005621MA2 090418 11005621MA2100118 11005621MA2 110218 11005621MA2120318 11005621MA2 070318 1100562.1MA2 080118 11b05621MA2 090418 11005621 MA2 100118 11005621 MA2 110218 11005621MA2120318 Radionuclide (Isotopic l)ranium (U))
1100-562-1MA1 U-233/234 u,. 235/236 3 Qtr.
U-238 U-233/234 U-235/236 4Qtr.
U-238 1100-562-1 MA2 U-233/234 U-235/236 3 Qtr.
U-238 U-233/234 U-235/236 4 Qtr.
U-238 N~ENCOUSA
~
Sample Date 8/1/18 9/3/18 10/1/18.
11/2/18 12/3/18 1/3/19 8/1/18 9/3/18' 10/1/18 11/2/18 12/3/18 1/3/19 8/1/18 9/3/18 10/1/18 11/2/18 12/3/18 1/3/19 8/1/18 9/3/18 10/1/18 11/2/18 12/3/18 1/3/19 Sample Date 10/3/2018 1/3/2019 10/3/2018 1/3/2019 Sample Period I Analyte 7/3/18 - 8/1/18 8/1/18 - 9/3/18 9/3/18 - 10/1/18 Gross 10/1/18 - 11/2/18 Alpha 11/2/18-12/3/18 12/3/18 - 1/3/19 7/3/18 - 8/1/18 8/1/18-9/3/18 9/3/18 - 10/1/18 Gross 10/1/18 - 11/2/18 Beta 11/2/18 - 12/3/18 12/3/18 - 1/3/19 1/3/18 - 8/1/18 8/1 /18 - 9/3/18 9/3/18-10/1/18 Gross 10/1/18-11/2/18 Alpha 11/2/18-12/3/18 12/3/18 - 1/3/19 7/3/18 - 8/1/18 8/1/18 - 9/3/18 9/3/18 -10/1/18 Gross 10/1/18-11/2/18 Beta 11/2/18 - 12/3/18 12/3/18 - 1/3/19 Result Sample Pl:lriOd
µCi/ml 2.30E-14 7/3/18-10/1/18 4.67E-16 6.44E-16 1.17E-16 10/1/18-1/3/19 3.85E-17 1.84E-16 1.61E-16 7/3/18-10/1/18 1.04E-16 8.21E-17 7.71E-17 10/1/18-1/3/19 9.53E-17 1.44E-16 Gross MD~/
Inst. Unc:.
Total Flow Quantity
%ofTable2 Result MOC
µCi/ml m3 Released Apgendix B
µCi/ml
µCi/ml G,i 10CFR20.
O.OOE+OO 1.82E-16 O.OOE+oo*
4.34E+05
<MDA
<MDA 1.31E-16 3.51E-16 6.31E-08 1.22E+05
<MDA
<MDA 1.63E-16 2.19E-16 9.01E-08 5.84E+04
<MDA
<MDA O.OOE+OO 1.81E-16 O.OOE+OO 4.29E+04
<MDA
<MDA 7.87E-17 2.07E-16 6.31E-08 O.OOE+OO
<MDA
<MDA O.OOE+OO 1.60E-16 O.OOE+OO 6.19E+05
<MDA
<MDA 5,34E-15 3.77E-15 1.41E-06 4.34E+05 2.32E-09 0.178%
1.40E~14 7.28E-15 1.49E-06 1.22E+05 1.71E-09 0.466%
!i.44E-15. 4.53E-15 1.29E-06 5.84E+04 3.18E-10 0.181%
7.43E-15 3.61E-15 1.51E-06 4.29E+04 3.19E-10 0.248%
6.75E-15 4.14E-15 1.39E-06 O.OOE+OO 0.00E+OO 0.225%
6.03E-15 3.19E-15 1.53E-06 6.19E+05 3.73E-09 0.201%
6.19E-17 1.66E-16 6.31E~08 5.73E+05
<MDA
<MDA 1.34E-16 1.80E-16 9.01E-08 1.22E+05
<MDA
'<MDA C 8.62E-17 2.3'1E.:15 6.31E-08 6.70E+p1
<MDA
<MDA
-2.78E-18 1.97E-16 6.31E-08 2.68E+01
<MDA
<MDA 2.78E-16 1.86E-16 1.22E-07 6.05E+03 1.68E-12 0.009%
O.OOE+OO 1..55E-16 O.OOE+OO 5.60E+05
<MDA
<MDA 4.32E-15 3.43E-15 1.31E-06 5.73E+05 2.48E-09 0.144%
6,17E-15 3.72E-15.
1.47E-06 1.22E+05 7.54E-10 0.206%
4.59E-15 4.78E-15 1.23E006 6.70E+01
<MDA
<MDA 8.18E-15 3.95E-15 1.64E-06 2.68E+01 2.19E-13 0.273%
7.66E-15 3.72E-15 1.51E-06 6.05E+03 4.64E-11 0.255%
1.98E-15 3.10E-15 1.08E-06 5.60E+05
<MDA
<MDA 2aTP:U 1aTPU MDC Total Flow Quantity 6/o of'rable 2
(µCi/ml)
µCi/ml
.(µCi/ml) m3 Released Appendix B Ci 10CFR20 4.14E-15
.4.46E-15 2.67E-16 0.00 0.77%
3.51E-16 3.53E-16 3.50E-16 6;14E+05 0.00 0.02%
3.61E-16 3.64E-16 2.25E-16 0.00 0.02%
8.78E-17 8.82E-17 8.19E-17 0.00 0.00%
6.55E-17 6.55E-17 1.15E-16 6.62E+05
<MDC
<MDC 1.07E-16 1.08E-16 6.48E-17 0.00 0.01%
8.50E-17 8.58E-17 5.26E-11
- 0.00 0.01%
7.61E-17 7.65E-17 6.49E-17 6.95E+05 0.00 0.00%
6.16E-17 6.18E-17 5.75E-17 0.00 0.00%'
6.35E-17 6.37E-17 7.76E-17
<MDC
<MDC 7.32E-17 7.36E-17 7.35E-17 5.66E+05 0.00 0.00%
7.84E-17 7.90E-17 5.03E-17 0.00 0.00%
TABLE 1-6 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 &
1100-562-2MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample Gross MDA/
Inst. Unc.
Total Flow I Quantity
% ofTable2 Sample ID Sample Period Analyte Result MDC 3
Released Appendix B Date
µCi/ml
'µCi/ml
µCi/ml m
- Ci 10CFR20 1100-562-2MA 1 11005622MA1 070318 8/1/18 7/3/18
- 8/1/18 2.68E-16 1.46E-16 1.40E-07 2.92E+07 7.83E-09 0.009%
11005622MA1 080118 9/3/18 8/1/18
- 9/3/18 2.90E-16 1.31E-16 1.53E-07 3.21E+07 9.32E-09 0.010%
11005622MA1 090418 10/1/18 9/3/18-10/1/18 Gross 3.75E-16 1.58E-16 1.67E-07
. 2.71E+07 1.01E-08 0.012%
11005622MA 1 100118 11/2/18 10/1/18-11/2/18 Alpha 2.47E-16 1.34E-16 1.40E-07 3.27E+07 8.06E-09 0.008%
11005622MA 1 110218 12/3/18 11/2/18-12/3/18 5.09E-17 1.34E-16 6.31E-08 3.05E+07
<MDA
<MDA 11005622MA 1 120318 1/3/19 12/3/18 - 1/3/19 1.53E-16 1.37E-16 1.08E-07 3.13E+07 4.79E-09 0.005%
1 11005622MA1 070318 8/1/18 7/3/18
- 8/1/18 4.16E-15 3.02E-15 1.34E-06 2.92E+07 1.22E-07 0.139%
11005622MA1 080118 9/3/18 8/1/18
- 9/3/18 2.87E-15 2.71E-15 1.32E-06 3.21E+07 9.22E-08 0.096%
11005622MA1 090418 10/1/18 9/3/18 - 10/1 /18 Gross 3.13E-15 3.27E-15 1.33E-06 2.71E+07
<MDA
<MDA 11005622MA1100118 11/2/18 10/1/18-11/2/18 Beta 5.69E-17 2.68E-15 1.53E-06 3.27E+07
<MDA
<MDA 11005622MA1110218 12/3/18 11/2/18-12/3/18 3.98E-15 2.68E-15 1.35E-06 3.05E+07 1.22E-07 0.133%
11005622MA1120318 1/3/19 12/3/18 - 1/3/19 7.00E-15 2.74E-15 1.63E-06 3.13E+07 2.19E-07 0.233%
1100-562-2MA2 11005622MA2 070318 8/1/18 7/3/18 - 8/1/18 2.34E-16 1.59E-16 1.26E-07 3.11E+07 7.27E-09 0.008%
11005622MA2 080118 9/3/18 8/1 /18 - 9/3/18 O.OOE+OO 1.40E-16 O.OOE+OO 3.40E+07
<MDA
<MDA 11005622MA2 090418 10/1/18 9/3/18-10/1/18 Gross 1.29E-16 1.79E-16 1.08E-07 2.84E+07
<MDA
<MDA 11005622MA2 100118 11/2/18 10/1/18-11/2/18 Alpha 9.89E-17 8.88E-17 1.08E-07 6.19E+07 6: 12E-09
. 0.003%
11005622MA2 110218 12/3/18 11/2/18-12/3/18 1.49E-16 1.34E-16 1.08E-07 3.27E+07 4.88E-09 0.005%
11005622MA2 120318 1/3/19 12/3/18 - 1/3/19 1.64E-15 4.31E-15 6.31E-08 3.21E+07
<MDA
<MDA 11005622MA2 070318 8/1/18 7/3/18-8/1/18 3.89E-15 3.30E-15 1.35E-06 3.11E+07 1.21E-07 0.130%
11005622MA2 080118 9/3/18 8/1/18
- 9/3/18 3.30E-15 2.89E-15 1.27E-06 3.40E+07 1.12E-07 0.110%
11005622MA2 090418 10/1/18 9/3/18 -10/1/18 Gross 5.16E-15 3.71E-15 1.46E-06 2.84E+07 1.46E-07 0.172%
11005622MA2 100118 11/2/18 10/1/18-11/2/18 Beta 3.02E-15 1.78E-15 1.41 E-06 6.19E+07 1.87E-07 0.101%
11005622MA2 110218 12/3/18 11/2/18-12/3/18 4.94E-15 2.68E-15 1.45E-06 3.27E+07 1.61E-07 0.165%
11005622MA2120318 1/3/19 12/3/18-1/3/19 1.53E-13 8.62E-14 1.43E-06 3.21E+07 4.91E-06 5.091%
Radionuclide Sample Result 2cr TPU 1crTPU MDC Total Flow Quantity 0/~ ofTable 2 (Isotopic Uranium (U))
-Date Sample Period
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Released Appendix B Ci 10CFR 20 1100-562-2MA1 U-233/234 1.99E-16 8.05E-17 8.17E-17 5.36E-17 1.76E-08 0.007%
U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 2.79E-18 2.76E-17 2.76E-17 6.83E-17 8.84E+07
<MDC
<MDC U-238 1.95E-16 7.86E-17 7.98E-17 4.73E-17 1.72E-08 0.007%
U-233/234 1.47E-14 2.81E-15 3.00E-15 1.82E-16 0.00 0.490%
U-235/236 4Qtr.
1/3/2019 10/1/18-1/3/19 5.56E-16 3.15E-16 3.18E-16 2.38E-16 9.46E+07 0.00 0.019%
U-238 1.49E-16 1.43E-16 1.44E-16 1.53E-16
<MDC
<MDC 1100-562-2MA2 U-233/234 2.18E-16 8.82E-17 8.96E-17 4.85E-17 2.04E-08 0.007%
U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 1.02E-16 6.65E-17 6.69E-17 5.07E-17 9.35E+07 0.00 0.003%
U-238 1.92E-16 8.24E-17 8.35E-17 4.49E-17 1.79E-08 0.006%
U-233/234 3.08E-16 1.48E-16 1.50E-16 8.33E-17 0.00 0.010%
U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 1.22E-16 1.04E-16 1.05E-16 1.03E-16 1.27E+08 0.00 0.004%
U-238 1.65E-16 1.09E-16 1.10E-16 9.10E-17 0.00 0.006%
@RENCOUSA
TABLE 1-7 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF): Local Extract Exhaust Gaseous Effluent Vent System, 1300-562-1 MA 1, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample Gross MDA/*
Inst. Unc.
Tqtal Flow Quantity
% of Table 2 Sample ID Date Sample Period Analyte Result MDC
µCi/ml m3 Released Appendix B
µCi/ml
µCi/ml Ci 10CFR20 1300-562-1MA1 13005621MA1 070518 8/1/18 7/5/18 - 8/1/18 6.19E-17 1.66E-16 6.31E-08 1.14E+07
<MDA
<MDA 13005621MA1 080118 10/1/18 8/1/18-10/1/18 9.13E-17 1.22E-16 9.01E-08 2.64E+07
<MDA
<MDA 13005621MA1100118 11/5/18 10/1 /18-11 /5/18 Gross 4.35E-17 1.17E-16 1.49E+07 Alpha 6.31E-08
<MDA
<MDA 13005621MA1110218 12/5/18 11/2/1 - 12/5/18 1.64E-16 1.47E-16 1.08E-07 1.27E+07 2.09E-09 0.005%
13005621MA1120518 1/3/19 12/5/18 - 1/3/19 1.59E-16 1.43E-16 1.08E-07 1.24E+07 1.98E-09 0.005%
13005621MA1 070518 8/1/18 7/5/18 - 8/1/18 3.09E-15 3.43E-15 1.21E-06 1.14E+07
<MDA
<MDA 13005621MA1 080118 10/1/18 8/1/18 - 10/1/18 4.57E-15 2.54E-15 1.46E-06 2.64E+07 1.21E-01 0.152%
13005621MA1100118 11/5/18 10/1/18-11/5/18 Gross 4.06E-15 2.41E-15 1.43E-06 1.49E+07 Beta 6.05E-08 0.135%
13005621MA1110218 12/5/18 11/2/1 -12/5/18 6.25E-15 2.94E-15 1.53E-06 1.27E+07 7.97E-08 0.208%
13005621MA1120518 1/3/19 12/5/18 - 1/3/19 4.66E-15 2.8.6E-15 1.39E-06 1.24E+07 5.78E-08 0.155%
Radionuclide Sample Result 2crTPU tcrTPU MDC Total Flow Quantity
% ofTable2 Sample Period Released Appendix B (Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Ci 10CFR 20 1300-562-1 MA1 U-233/234 2.16E-16 1.05E-16 1.06E-16 6.49E-17 3.78E+07 0.00 0.01%
U-235/236 3 Qtr.
10/1/2018 7/5/18-10/1/18 1.22E-16 9.05E-17 9.09E-17 9.15E-17 0.00 0.00%
U-238 1.74E-16 9.54E-17 9.62E-17 7.38E-17 0.00 0.01%
U-233/234 7.56E-17 5.30E-17 5.33E-17 5.68E-17 0.00 0.00%
U-235/236 4 Qtr.
1/3/2018 10/.1/18-1/3/19 3.25E-17 4.45E-17 4.46E-17 7.24E-17 4.01E+07
<MDC
<MDC U-238 1.35E-16 6.76E-17 6.83E-17 5.01E-17 0.00 0.00%
Notes:
A.
13005621MA1 monitor out of operation 8/23/18. Monitor in operation on 09/19/18. During this time, all material had been removed from the CAB.
@_iENCOUSA
URENCO USA: Report of Radioactivity in Effluents: Liquid & Air: July 2018 - December 2018 There were no releases to the public during the reporting period that exceeded regulatory requirements.
Detected isotopic uranium activities were comparable to pre-operational activities. No dose assessment was performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points were acceptable. The potential maximum doses directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentrations.
In liquid effluent, the concentrations of isotopic uranium was either below the Minimum Detectable Concentration (MDC) or less that 10% of values listed in 10 CFR 20, Appendix B, Table 3, "Releases to Sewers" (Table 1-1 ).
In gaseous effluent, the gross uranium activity was either below the Minimum Detectable Activity (MDA) or less than 10% of values listed in 1 O CFR 20, Appendix B, Table 2, "Effluent Concentrations - Class D Air" for U234, U235, and U238.
The concentrations of isotopic uranium in gaseous effluent was either below the Minimum Detectable Concentration (MDC) or less that 10% of values listed in 10 CFR 20.1301, 10 CFR 20.1302, and 10 CFR 20.1101 (d), as described in NRC Regulatory Guide 4.20 "Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors" dated December 1996.
LIST OF TABLES Table No.
1-1 1-2 1-3 1-4 1-5 1-6 1-7 Title Lift Station 1 Wastewater Effluent - Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1001 (SBM 1001) Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1MA1 & 1001-562-1MA2-Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1003 (SBM 1003) Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA1 & 1003-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1005 (SBM 1005) Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 & 1005-562-1MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Local Extract Exhaust Gaseous_Effluent Vent System, 1100-562-1 MA1 & 1100-562-1 MA2 - Gross Alpha &
Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA 1 & 1100-562-2MA2 - Gross Alpha &
Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF) Exhaust Filtration System Gaseous Effluent - 1300-562-1 MA 1 Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 c~RENCOUSA
TABLE 1-1 Lift Station 1 Wastewater Effluent - Radionuclides, Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Total Counting Quantity
% of Table 3 of Appendix B Radionuclide Sample Date Sample Period Time Results Uncertainty Total Flow*
Released to 1 O CFR 20 Values-(Datemrre)
(days)
(µCi/ml)
(µCi/ml)
(gallons/day)
(Ci)
Monthly Average Release to Sewers Lift Station 1 - July-December 2018 Uranium - 233/234 2.10E-10 5.00E-11 13,000 Result Below LLD Result Below LLD Uranium - 235/236 10/8/2018 9:20 07/01/18 - 12/31/18 183 O.OOE+OO O.OOE+OO 13,000 Result Below LLD Result Below LLD Uranium - 238 2.70&10 5.00E-11 13,000 Result Below LLD Result Below LLD Lift Station 1 Duplicate - July-December 2018 Uranium - 233/234 1.40&10 3.00E-11 13,000 Result Below LLD Result Below LLD Uranium - 235/236 10/8/2018 9:25 07/01/18-12/31/18 183 O.OOE+OO O.OOE+OO 13,000 Result Below LLD Result Below LLD Uranium - 238 9.00E-11 3.00E-11 13,000. Result Below LLD Result Below LLD Notes:
- 1. * = Table 3.4-4 "Anticipated Normal Plant Water Consumption" from the Environmental Report, Rev. 19, lists Total Personnel Water Use" as approximately 13,000 gallons per day.
- 2. µCi/ml = microCuries per milliliter.
- 3. Radionuclides analyzed using method EICHROM AC01 by Cardinal Laboratories of Hobbs, NM (subcontracted to Radiation Safety Engineering of Chandler, AZ.).
- 4. Quantity released is calculated if the result equals or exceeds the LLD. Facility-required lower level of detection (LLD) is 3.0E-9 uCi/mL.
@_iENCOUSA
TABLE 1-2 Separations Building Module-1001 (SBM 1001 ): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA 1 & 1001-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico.
Sample Gross MDA/
Inst. Unc.
Total Flow Quantity
% ofTable2 Sample ID Sample Period Analyte Result MDC Released Appendix B Date
µCi/ml
µCi/ml
µCi/ml
'm3 Ci
- 10CFR 20 1001-562-1 MA1 10015621MA1 070318 8/1/18 7/3/18 - 8/1/18 6.25E-17 1.67E-16 6.31E-08 4.39E+05
<MDA
<MDA 10015621MA1 080118 9/3/18 8/1/18 - 9/3/18 5.44E-17 1.46E-16 6.31E-08 5.20E+05
<MDA
<MDA 10015621MA1 090418 10/1/18 9/3/18-10/1/18 Gross O.OOE+OO 1.85E-16 O.OOE+OO 4.10E+05
<MDA
<MDA 10015621MA1100118 11/2/18 10/1/18-11/2/18 Alpha
-2.17E-18 1.54E-16 6.31E-08 4.82E+05
<MDA
<MDA 10015621MA1110218 12/3/18 11/2/18-12/3/18 1.14E-17 1.55E-17 8.56E-08 5.01E+05
<MDA
<MDA 10015621MA1120318 1/3/19 12/3/18 - 1/3/19 6.36E-17 1.67E-16 6.31E-08 5.04E+05
<MDA
<MDA 10015621MA1 070318 8/1/18 7/3/18-8/1/18 6.03E-15 3.47E-15 1.44E-06 4.39E+05 2.65E-09 0.201%
10015621MA1 080118 9/3/18 8/1/18 - 9/3/18 4.53E-15 3.02E-15 1.38E-06 5.20E+05 2.35E-09 0.151%
10015621MA1 090418 10/1/18 9/3/18-10/1/18 Gross 2.76E-15 3.~3E-15 1.15E-06 4.10E+05
<MDA
<MDA 10015621MA1100118 11/2/18 10/1/18-11/2/18 Beta 6.15E-15 3.07E-15 1.62E-06 4.82E+05 2.96E-09 0.205%
10015621MA1110218 12/3/18 11 /2/18-12/3/18 6.16E-16 3.10E-16 1.49E-06 5.01E+05 3.08E-10 0.021%
10015621MA1120318 1/3/19 12/3/18 - 1/3/19 4.98E-15 3.35E-15 1.35E-06 5.04E+05 2.51E-09 0.166%
1001-562-1MA2 10015621MA2 070318A 8/1/18 6/1/18-8/1/18 1.92E-16 2.58E-16 9.01E-08 9.54E+05
<MDA
<MDA 10015621MA2 080118 9/3/18 8/1/18-9/3/18 1.48E-16 1.99E-16 9.01E-08 5.38E+05
<MDA
<MDA 10015621MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 6.31E-18 1.69E-17 6.31E-08 4.31E+05
<MDA
<MDA 10015621MA2100118 11/2/18 10/1/18-11/2/18 Alpha O.OOE+OO 1.41E-16 O.OOE+OO 5.04E+05
<MDA
<MDA 10015621MA2110218 12/3/18 11 /2/18-12/3/18 O.OOE+OO 1.41 E-16 O.OOE+OO 5.14E+05
<MDA
<MDA 10015621MA2120318 1/3/19 12/3/18 - 1/3/19 1.04E-16 1.42E-16 8.56E-08 5.17E+05
<MDA
<MDA 10015621MA2 070318A 8/1/18 6/1/18 - 8/1/18 5.76E-15 5.34E-15 1.26E-06 9.54E+05 5.49E-09 0.192%
10015621MA2 080118 9/3/18 8/1/18 - 9/3/18 6.67E-15 4.12E-15 1.41E-06 5.38E+05 3.59E-09 0.222%
10015621MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 3.99E-16 3.50E-16 1.27E-06 4,31E+05 1.72E-10 0.013%
10015621MA2100118 11/2/18 10/1/18-11/2/18 Beta 5.38E-15 2.81E-15 1.47E-06 5.04E+05 2.71E-09 0.179%
10015621MA2110218 12/3/18 11 /2/18-12/3/18 4.39E-15 2.81E-15 1.37E-06 5.14E+05 2.26E-09 0.146%
10015621MA2 120318 1/3/18 12/3/18 - 1/3/19 4.96E-15 2.84E-15 1.49E-06 5.17E+05 2.56E-09 0.165%
Quantity
% ofTable2 Rac;lionuclide Sample Sample Period Result 2aTPU 1aTPU MDC Total Flow Released Appendix 8_
(Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Ci 10CFR 2d 1001-562-1 MA 1 U-233/234 1.67E-16 8.83E-17 8.91E-17 6.60Ec17 0.00 0.01%
U-235/236 3 Qtr.
10/1/18 7/3/18-10/1/18 7.92E-17 6.59E-17 6.61E-17 5.67E-17 1.37E+06 0.00 0.00%
U-238 1.88E-16 9.34E-17 9.43E-17 6.57E-17 0.00 0.01%
U-233/234 2.68E-17 1.63E-17 1.64E-17 1.60E-17 1.49E+06 0.00 0.00%
U-235/236 4 Qtr.
1/3/19 10/1/18-1/3/19 2.59E-17 1.78E-17 1.79E-17 1.84E-17 0.00 0.00%
U-238 3.03E-17 1.74E-17 1.75E-17 1.69E-17 0.00 0.00%
1001-562-1MA2 U-233/234 1.78E-17 1.44E-17 1.45E-17 1.61E-17 0.00 0.00%
3 Qtr.
10/1/18 6/1/18-10/1/18 1.53E-17 1.53E-17 1.51E-17 1.92E+06 U-235/236 1.78E-17 0.00 0.00%
U-238 3.18E-17 1.83E-17 1.84E-17 1.34E-17 0.00 0.00%
U-233/234 1.84E-16 7.38E-17 7.49E-17 4.22E-17 0.00 0.01%
U-235/236 4 Qtr.
1/3/19 10/1/18-1/3/19 5.50E-17 4.57E-17 4.59E-17 4.91E-17 1.53E+06 0.00 0.00%
U-238 7.13E-17 4.64E-17 4.66E-17 4.20E-17 0.00 0.00%
Notes:
A. 10015621 MA2 070318, filter was put on 6/1/18 and removed 8/1/18. Monitor out of operation on 6/10/18 due to faulty pump. Monitor in operation on 7/19/18. Filter left on for duration.
(':;.-';,
~RENCOUSA
TABLE 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA 1 &
1003-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample Gross MDA/
Inst. Unc.
Total Flow Quantity Sample ID Sample Period Analyte Result MDC Release.d Date
µCi/ml
µCi/ml
µCi/ml m3
.Ci 1003-562-1MA1 10035621MA1 070318 08/01/18 7/3/18-8/1/18
-3.33E-01 1.34E-16 6.31E-08 4.63E+05
<MDA 10035621MA1080118A 11/02/18 8/1/18 - 11/2/18 Gross 6.20E-17 4.23E-17 1.48E+06 Alpha 1.22E-07 9.15E-11 10035621MA11102188 1/03/18 11/2/18 - 1/3/19 2.35E-17 6.17E-17 6.31E-08 1.05E+06
<MDA 10035621MA1 070318 08/01/18 7/3/18 - 8/1/18 4.33E-15 2.78E-15
- 1.68E-06 4.63E+05 2.00E-09 10035621 MA 1 080118A 11/02/18 8/1/18 - 11/2/18 Gross 1.30E-15 8.75E-16 1.37E-06 1.48E+06 Beta 1.91E-09 10035621MA11102188 1/03/18 11/2/18 -1/3/19 1.37E-15 1.23E-15 1.32E-06 1.05E+06 1.43E-09 1003-562-1 MA2 10035621MA2 070318 08/01/18 7/3/18-8/1/18 Gross
-8.24E-18 1.29E-16 9.01E-08 4.93E+05
<MDA 10035621MA2 080118c 08/16/18 8/1/18 - 8/16/18 Alpha 0.00E+OO 2.67E-16 O.OOE+OO 2.48E+05
<MDA 10035621MA2 070318 08/01/18 7/3/18-8/1/18 Gross 2.62E-15 2.67E-15 1.64E-06 4.93E+05
<MDA 10035621MA2 080118c 08/16/18 8/1/18-8/16/18 Beta 6.96E-15 5.52E-15 1.31E-06 2.48E+05 1.73E-09 Radionuclide Sample I Sample Period Result 2oTPU 1oTPU MDC Total Flow. Quantity
{Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Released Ci 1003-562*1 MA1 U-233/234 8.69E-17 4.61E-17 4.65E-17 4.70E-17 1.94E+06 0.00 U-235/236 3 Qtr.
11/2/2018 7/3/18-11/2/18 6.86E-17 4.24E-17 4.27E-17 3.68E-17 0.00 U-238 4.70E-17 3.29E-17 3.31E-17 3.53E-17 0.00 U-233/234 1.08E-16 6.36E-17 6.41E-17 4.42E-17 1.05E+06 0.00 U-235/236 4 Qtr.
1/3/2019 11/2/18-1/3/19 7.40E-17 5.98E-17 6.01 E-17 5.98E-17 0.00 U-238 1.39E-16 7.35E-17 7.42E-17 5.51E-17 0.00 1003-562-1 MA2 U-233/234 2.74E-16 1.19E-16 1.20E-16 6.93E-17 0.00 U-235/236 3 Qtr.
8/16/18 8/1/18-8/16/18 6:70E-17 6.72E-17 6.33E-17 1.39E+06 7.32E-17 0.00 U-238 1.96E-16 1.01E-16 1.02E-16 7.34E-17 0.00 Notes:
A.
10035621MA1 080118, filter was put on 8/1/18 and removed 11/2/18.
B.
10035621MA1 110218, filter was put on 11/2/18 and removed 1/3/19.
C.
Redundant monitor out of operation on 8/15/18 due to faulty pump.
% ofTable2 Appendix *B 10CFR 20
<MDA 0.002%
<MDA 0.144%
0.043%
0.046%
<MDA
<MDA
<MDA 0.232%
% ofTable2 Appendix B 10CFR 20 0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.01%
0.00%
0;01%
TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1 MA 1 &
1005-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico
- Sample
.Gross fy!P.A /
- Inst. Unc.
Total Flow Quantity Sample ID Sample Period Analyte Result
- MDC Released*
Date
µCi/ml
µCi/ml
- µCi/ml J'Jl3 Ci 1005-562-1 MA1 10055621MA1 070318 8/1/18 7/3/18 - 8/1/18 O.OOE+OO 1.71E-*16 O.OOE+OO 8.28E+05
<MDA 10055621MA1 080118 9/3/18 8/1/18 - 9/3/18
- 1.11E-16 1.48E-16 9.01E-08 9.46E+05
- <MDA 10055621MA1 090418 10/1/18 9/3/18 -10/1/18 Gross 6.84E-17 1.83E-16 6.31E-08 7.79E+05
<MDA 10055621MA1100118 11/2/18 10/1/18-11/2/18 Alpha 5.79E-17 1.52E-16 6.31E-08 9.27E+05
<MDA 10055621MA1110218 12/3/18 11/2/18-12/3/18 1.17E-16 1.60E-16 8.56E-08 8.97E+05
<MDA 10055621MA1120318 1/3/19 12/3/18
- 1/3/19
-6.19E-17 1.63E-16 2.05E-10 8.95E+05
<MDA 10055621MA1 070318 8/1/18 7/3/18 - 8/1/18 5.10E-15 3.54E-15 1.36E-06 8.28E+05 4.22E-09 10055621MA1 08011.8 9/3/18 8/1/18 - 9/3/18 2'.95E-15 3.07E-15 1.23E-06 9.46E+05
<MDA
- 10055621MA1090418 10/1/18 9/3/18 -10/1/18 Gross 4.78E-15 3.79E-15 1.31E-06 7.791;+05 3.72E-09 10055621MA1100118 11/2/18 10/1/18-11/2/18 Beta 6.05E-15 3.05E-15 1.49E-06 9.27E+05 5.60E-09 10055621MA1110218 12/3/18 11 /2/18-12/3/18 4.53E-15 3.19E-15 1.33E-06 8.97E+05 4.06E-09 10055621MA1 120318 1/3/19 12/3/18-1/3/19 5.35E-15 3.25E-15 1.53E-06 8.95E+05 4.79E-09 1005-562-1 MA2 10055621 ~
07,0318 8/1/18 7/3/18 - 8/1/18 1.33E-16 1.78E-16 9.0tE-08 8.44E+05
<MDA 10055621MA2 080118 9/3/18 8/1/18 - 9/3/18 O.OClE+OO 1.54E-16 0.00E+OO 9.88E+05
<MDA 10055621MA2 090418 10/1/18 9i3/18-10/1/18 Gross 2.82E-16 1.92E-16 1.26E-07
.7.93E+05 2.24E-10 10055621MA2100118 11/2/18 10/1/18-11/2/18 Alpha 1.78E-16 1.60E-16 1.08E-07 9.35E+05 1.66E-10 10055621MA2110218 12/3/18 11/2/18-12/3/18 O.OOE+OO 1.63E-16 O.OOE+OO 9.13E+05
<MDA 10055621MA2 120318 1/3/19 12/3/18 - 1/3/19 6.37E-17 1.68E-16 6.31E-08 8.97E+05
<MDA 10055621MA2 070318 8/1/18 7/3/18-8/1/18 7.52E-15.
3.68E-15 1.51E-06 8.44E+05 6.34E-09
- 10055621MA2 080118 9/3/18 8/1/18 - 9/3/18 3.63E-15 3.18E-15 1.27E-06 9.88E+05 3.59E-09 10055621MA2 090418 10/1/18 9/3/18 -10/1l18 Gross 4:06E-15 3.98E-15 1.24E-06.
7.93E+05 3.22E-09 10055621MA2100118 11/2/18 10/1/18-11/2/18 Beta 2.49E-15 3.19E-15 1.13E-06 9.35E+05
<MDA 10055621MA2110218 12/3/18 11/2/18-12/3/18 7.62E-15 3.25E-15 1.58E-06 9.13E+05 6.96E-09 10055621MA2120318 1/3/19 12/3/18 - 1/3/19 7.61 E-15 3.35E-15 1.56E-06 8.97E+05 6.83E-09 Quantity.
Radionuclide
$ample
.Sarnple.~eriocl Re.suit 2dTPU 1.cr TPl)
MDC.
J9talFlow Rele.ased (Isotopic Uranium.(U))
Date
'µCi/ml
(µCi/ml).. *,.
µCif[lll
'(µCi/ml) m3 Ci 1005-562-1 MA 1 U-233/234 2,18E-16 9.35E-17 9.48E-17
.5.09E-17 0.00
- U-235/236 3 Qtr.
10/1/2018 7/3/18-.10/1/18 7.18E-17 6.24E-17 6.26E-17 7.18E-17 2.55E+06 0.00 U-238 1.24E-16 6.93E-17 6.99Es17
.I 4.03E-17 0.00 U-233/234 2.27E-16 8.80E-17 8.95E-17 5.10E-10 2.72E+06
<MDC U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 1.10E-16 6.85E-17 6.90E-17 5.99E-17 0.00 U-238 1.60E-16 7.21E-17 7.30E-17 3.37E-17 4.35E-10 1005-562-1 MA2
. U-233/234 9.46E-17 7.80E-17 7.83E-17 9.52E-17
<MDC U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 3.31E-17 3.311::-17 9.02E-17 2.62E+06 5.12E-18
<MDC Us238 1.12E-16
- i70E-17 7.74E-17 6.1JE-17 0.00*
U-233/234.
1.58E-16 7.99E-17 8.07E-17 5.46E-17 4.34E-10 U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 8.16E-17 6.25E-17 6.28E-17 4.99E-17 2.75E+06 0.00 U-238 2.03E-16 9.06E-17 9.18E-17 5.78E-17 5.57E-10
~ENCOUSA
% ofTable2 Appendix B 10CFR20
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA 0.170%
<MDA 0.159%
0.202%
0.151%
0.178%
<MDA
<MDA 0.009%
0.006%
<MDA
<MDA 0.251%
0.121%
0.135%
<MDA 0.254%
0.254%
% ofTable2 :'
Appendix 6 10CFR 20 0.01%
0.00%
0.00%
<MDC 0.00%
0.005%
<MDC
<MDC 0.00%
0.005%
0.00%
0.007%
TABLE 1-5 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA1 &
1100-562-1MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample G.ross MDA/
Inst. Unc.
T.otal Flow Quantity.
% of Table 2
- Sample ID Sample Period Analyte Result MD*c Released Appendix B Date
µCi/ml
µCi/ml
µCi/ml.
m3 Ci 10CFR 20 1100-562-1MA1 11005621MA1 070318 8/1/18 7/3/18-8/1/18 O.OOE+OO 1.82E-16 O.OOE+OO 4.34E+05
<MDA
<MDA 11005621MA1 080118 9/3/18 8/1/18 - 9/3/18 1.31E-16 3.51E-16 6.31E-08 1.22E+05
<MDA
<MDA 11005621MA1 090418 10/1/18 9/3/18-10/1/18 Gross 1.63E-16 2.19E-16 9.01E-08 5.84E+04
<MDA
<MDA 11005621MA1100118 11/2/18 10/1/18-11/2/18 Alpha O.OOE+OO 1.81E-16 O.OOE+OO 4.29E+04
<MDA
<MDA 11005621 MA 1 110218 12/3/18 11/2/18-12/3/18 7.87E-17 2.07E-16 6.31E-08 O.OOE+OO
<MDA
<MDA 11005621MA1120318 1/3/19 12/3/18 - 1/3/19 O.OOE+OO 1.60E-16 O.OOE+OO 6.19E+05
<MDA
<MDA 11005621MA1 070318 8/1/18 7/3/18 - 8/1/18 5.34E-15 3.77E-15 1.41E-06 4.34E+05 2.32Es09 0.178%
11005621MA1 080118 9/3/18 8/1/18 - 9/3/18 1.40E-14 7.28E-15 1.49E-06 1.22E+05 1.71E-09 0.466%
11005621MA1 090418 10/1/18 9/3/18 - 10/1118 Gross 5.44E-15 4.53E-15 1.29E-06 5.84E+04 3.18E-10 0.181%
11005621 MA1 100118 11/2/18 10/1/18 - 11/2/18 Beta 7.43E-15 3.61 E-15 1.51E-06 4.29E+04 3.19E-10 0.248%
11005621MA1110218 12/3/18 11/2/18 - 12/3/18 6.75E-15 4.14E-15 1.39E-06 O.OOE+OO O.OOE+OO 0.225%
11005621MA1120318 1/3/19 12/3/18 - 1/3/19 6.03E-15 3.19E-15 1.53E-06 6.19E+05 3.73E-09 0.201%
1100-562-1 MA2 11005621MA2 070318 8/1/18 7/3/18 - 8/1/18 6.19E-17 1.66E-16 6.31E-08 5.73E+05
<MDA
<MDA 11005621MA2 080118 9/3/18 8/1/18 - 9/3/18 1.34E-16 1.80E-16 9.01E-08 1.22E+05
<MDA
<MDA 11005621MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 8.62E-17 2.31 E-16 6.31E-08 6.70E+01
<MDA
<MDA 11005621MA2100118 11/2/18 10/1 /18 - 11 /2/18 Alpha
-2.78E-18 1.97E-16 6.31E-08 2.68E+01
<MDA
<MDA 11005621MA2 110218 12/3/18 11/2/18-12/3/18 2.78E-16 1.86E-16 1.22E-07 6.05E+03 1.68E-12 0.009%
11005621MA2 120318 1/3/19 12/3/18 - 1/3/19 O.OOE+OO 1.55E-16 O.OOE+OO 5.60E+05
<MDA
<MDA 11005621MA2 070318 8/1/18 7/3/18 - 8/1/18 4.32E-15 3.43E-15 1.31E-06 5.73E+05 2.48E-09 0.144%
11005621MA2 080118 9/3/18 8/1/18 - 9/3/18 6.17E-15 3.72E-15 1.47E-06 1.22E+05 7.54E-10 0.206%
11005621MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 4.59E-15 4.78E-15 1.23E-06 6.70E+01
<MDA
<MDA 11005621 MA2 100118 11/2/18 10/1/18-11/2/18 Beta 8.18E-15 3.95E-15 1.64E-06 2.68E+01 2.19E-13 0.273%
11005621MA2110218 12/3/18 11/2/18-12/3/18 7.66E-15 3.72E-15 1.51E-06 6.05E+03 4.64E-11 0.255%
11005621MA2 120318 1/3/19 12/3/18 - 1/3/19 1.98E-15 3.10E-15 1.08E-06 5.60E+05
<MDA
<MDA Radi.onuclide Sample Result 2crTPU 1cr TPU MDC T.otal Flow Quantity
% ofTable2 Sample Period Released Appendix l;3 (Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Ci 10CFR 20 1100-562-1MA1 U-233/234 2.30E-14 4.14E-15 4.46E-15 2.67E-16 0.00 0.77%
'U-235/236 3 Qtr.
10/3/2018 7/3/18-10/1/18 4.67E-16 3.51E-16 3.53E-16 3.50Ea16 6.14E+05 0.00 0.02%
U-238 6.44E-16 3.61E-16 3.64E-16 2.25E-16 0.00 0.02%
U-233/234 1.17E-16 8.78E-17 8.82E-17 8.19E-17 0.00 0.00%
U-235/236 4Qtr.
1/3/2019 10/1 /18-1 /3/19 3.85E-17 6.55E-17 6.55E-17 1.15E-16 6.62E+05
<MDC
<MDC U-238 1.84E-16 1.07E-16 1.08E-16 6.48E-17 0.00 0.01%
1100-562-1 MA2 U-233/234 1.61E-16 8.SOE-17 8.58E-17 5.26E-17 0.00 0.01%
U-235/236 3 Qtr.
10/3/2018 7/3/18-10/1/18 1.04E-16 7.61E-17 7.65E-17 6.49E-17 6.95E+05 0.00 0.00%
U-238 8.21E-17 6.16E-17 6.18E-17 5.75E-17 0.00 0.00%
U-233/234 7.71E-17 6.35E-17 6.37E-17 7.76E-17
<MDC
<MDC U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 9.53E-17 7.32E-17 7.36E-17 7.35E-17 5.66E+05 0.00 0.00%
U-238 1.44E-16 7.84E-17 7.90E-17 5.03E-17 0.00 0.00%
(':.- :..,.,
~RENCOUSA
TABLE 1-6 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 &
1100-562-2MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 UREN CO USA Lea County, New Mexico Sample Gross MDA/
Inst. Unc.
Total Flow Quantity
% ofTable2 Sample ID Sample Period Analyte Result MDC Released Appendix B Date
µCi/ml
µCi/ml
µCi/ml m3 Ci 10CFR20 1100-562-2MA1 11005622MA1 070318 8/1/18 7/3/18 - 8/1/18 2.68E-16 1.46E-16 1.40E-07 2.92E+07 7.83E-09 0.009%
11005622MA1 080118 9/3/18 8/1 /18 - 9/3/18 2.90E-16 1.31E-16 1.53E-07 3.21E+07 9.32E-09 0.010%
11005622MA 1 090418 10/1/18 9/3/18-10/1/18 Gross 3.75E-16 1.58E-16 1.67E-07 2.71E+07 1.01E-08 0.012%
11005622MA1100118 11/2/18 10/1/18-11/2/18 Alpha 2.47E-16 1.34E-16 1.40E-07 3.27E+07 8.06E-09 0.008%
11005622MA1110218 12/3/18 11 /2/18-12/3/18 5.09E-17 1.34E-16 6.31E-08 3.05E+07
<MDA
<MDA 11005622MA1 120318 1/3/19 12/3/18-1/3/19 1.53E-16 1.37E-16 1.08E-07 3.13E+07 4.79E-09 0.005%
11005622MA1 070318 8/1/18 7/3/18
- 8/1/18 4.16E-15 3.02E-15 1.34E-06 2.92E+07 1.22E-07 0.139%
11005622MA1 080118 9/3/18 8/1/18 - 9/3/18 2.87E-15 2.71E-15 1.32E-06 3.21E+07 9.22E-08
- 0.096%
11005622MA1 090418 10/1/18 9/3/18 - 10/1/18 Gross 3.13E-15 3.27E-15 1.33E-06 2.71E+07
<MDA
<MDA 11005622MA1 100118 11/2/18 10/1/18-11/2/18 Beta 5.69E-17 2.68E-15 1.53E-06 3.27E+07
<MDA
<MDA 11005622MA1110218 12/3/18 11/2/18-12/3/18 3.98E-15 2.68E-15 1.35E-06 3.05E+07 1.22E-07 0.133%
11005622MA 1 120318 1/3/19 12/3/18 - 1/3/19 7.00E-15 2.74E-15 1.63E-06 3.13E+07 2.19E-07 0.233%
1100-562-2MA2 11005622MA2 070318 8/1/18 7/3/18-8/1/18 2.34E-16 1.59E-16 1.26E-07 3.11E+07 7.27E-09 0.008%
11005622MA2 080118 9/3/18 8/1 /18 - 9/3/18 O.OOE+OO 1.40E-16 O.OOE+OO 3.40E+07
<MDA
<MDA 11005622MA2 090418 10/1/18 9/3/18 -10/1/18 Gross 1.29E-16 1.79E-16 1.08E-07 2.84E+07
<MDA
<MDA 11005622MA2 100118 11/2/18 10/1 /18-11 /2/18 Alpha 9.89E-17 8.88E-17 1.08E-07 6.19E+07 6.12E-09 0.003%
11005622MA2110218 12/3/18 11 /2/18-12/3/18 1.49E-16 1.34E-16 1.08E-07 3.27E+07 4.88E-09 0.005%
11005622MA2 120318 1/3/19 12/3/18 -1/3/19 1.64E-15 4.31E-15 6.31E-08 3.21E+07
<MDA
<MDA 11005622MA2 070318 8/1/18 7/3/18-8/1/18 3.89E-15 3.30E-15 1.35E-06 3.11E+07 1.21E-07 0.130%
11005622MA2 080118 9/3/18 8/1/18
- 9/3/18 3.30E-15 2.89E-15 1.27E-06 3.40E+07 1.12E-07 0.110%
11005622MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 5.16E-15 3.71E-15 1.46E-06 2.84E+07 1.46E-07 0.172%
11005622MA2 100118 11/2/18 10/1/18-11/2/18 Beta 3.02E-15 1.78E-15 1.41 E-06 6.19E+07 1.87E-07 0.101%
11005622MA2 110218 12/3/18 11/2/18-12/3/18 4.94E-15 2.68E-15 1.45E-06 3.27E+07 1.61 E-07 0.165%
11005622MA2 120318 1/3/19 12/3/18 - 1/3/19 1.53E-13 8.62E-14 1.43E-06 3.21E+07 4.91E-06 5.091%
Radionuclide Sample Result 2aTPU 1p-TPU MDC*
Total Flow Quantity
% of Table 2
- Sample Period Released Appendix B (Isotopic Uranium (U))
(?ate
µCi/ml
(µCi/ml)
µCi/rnl
(µCi/ml) m3 Ci 10CFR20 1100-562-2MA1 U-233/234 1.99E-16 8.05E-17 8.17E-17 5.36E-17 1.76E-08 0.007%
U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 2.79E-18 2.76E-17 2.76E-17 6.83E-17 8.84E+07
<MDC
<MDC U-238 1.95E-16 7.86E-17 7.98E-17 4.73E-17 1.72E-08 0.007%
U-233/234 1.47E-14 2.81E-15 3.00E-15 1.82E-16 0.00 0.490%
U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 5.56E-16 3.15E-16 3.18E-16 2.38E-16 9.46E+07 0.00 0.019%
U-238 1.49E-16 1.43E-16 1.44E-16 1.53E-16
<MDC
<MDC 1100-562-2MA2 U-233/234 2.18E-16 8.82E-17 8.96E-17 4.85E-17 2.04E-08 0.007%
~
U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 1:02E-16 6.65E-17 6.69E-17 5.07E-17 9.35E+07 0.00 0.003%
U-238 1.92E-16 8.24E-17 8.35E-17 4.49E-17 1.79E-08 0.006%
U-233/234 3.08E-16 1.48E-16 1.50E-16 8.33E-17 0.00 0.010%
U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 1.22E-16 1.04E-16 1.05E-16 1.03E-16 1.27E+OB 0.00 0.004%
U-238 1.65E-16 1.09E-16 1.10E-16 9.10E-17 0.00 0.006%
TABLE 1-7 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF): Local Extract Exhaust Gaseous Effluent Vent System, 1300-562-1 MA 1, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample Gross MDA/
Inst. Unc.
Total Flow Quantity
% ofTable2 Sample ID Sample Period An<:1lyte Result MDC Released Appendix B D1;1te
µCi/ml
µCi/ml 1,.1Ci/ml m3.
Ci 10CFR20 1300-562-1MA1 13005621MA1 070518 8/1/18 7/5/18 - 8/1/18 6.19E-17 1.66E-16 6.31E-08 1.14E+07
<MDA
<MDA 13005621MA1 080118 10/1/18 8/1/18 - 10/1/18 9'131:-17 1.22E-16 9.01E0 08 2.64E+07
<MDA
<MDA 13005621MA1100118 11/5/18 10/1/18-11/5/18 Gross 4.35E-17 1.17E-16 1.49E+07 Alpha 6.31E-08
<MDA
<MDA 13005621MA1110218 12/5/18 11/2/1 - 12/5/18 1.64E-16 1.47E-16 1.08E-07 1.27E+07 2.09E-09 0.005%
13005621MA1120518 1/3/19 12/5/18 - 1/3/19 1.59E-16 1.43E-16 1.08E-07 1.24E+07 1.98E-09 0.005%
13005621MA1 070518 8/1/18 7/5/18 - 8/1/18 3.09E-15 3.43E-15 1.21E-06 1.14E+07
<MDA
<MDA 13005621MA1 080118 10/1/18 8/1/18-10/1/18 4.57E-15 2.54E-15 1.46E-06 2.64E+07 1.21E-07 0.152%
13005621MA1100118 11/5/18 10/1/18-11/5/18 Gross 4.06E-15 2.41E-15 1.43E-06 1.49E+07 0.135%
Beta 6.05E-08 13005621MA1110218 12/5/18 11/2/1 - 12/5/18 6.25E-15 2.94E-15 1.53E-06 1.27E+07 7.97E-08 0.208%
13005621MA1 120518 1/3/19 12/5/18 - 1/3/19 4.66E-15 2.86E-15 1.39E-06 1.24E+07 5.78E-08 0.155%
Radionuclide Sample Result 2aTPU 1aTPU MDC Total Flow Quantity
% ofTable2 Sample Period Released Appendix B (Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Ci 10CFR 20 1300-562-1 MA 1 U-233/234 2.16E-16 1.05E-16 1.06E-16 6.49E-17 3.78E+07 0.00 0.01%
U-235/236 3 Qtr.
10/1/2018 7/5/18-10/1/18 1.22E-16 9.05E-17 9.09E-17 9.15E-17 0.00 0.00%
U-238 1.74E-16 9.54E-17 9.62E-17 7.38E-17 0.00 0.01%
U-233/234 7.56E-17 5.30E-17 5.33E-17 5.68E-17 0.00 0.00%
U-235/236 4 Qtr.
1/3/2018 10/1/18-1/3/19 3.25E-17 4.45E-17 4.46E-17 7.24E-17 4.01E+07
<MDC
<MDC U-238 1.35E-16 6.76E-17 6.83E-17 5.01E-17 0.00 0.00%
Notes:
A.
13005621 MA1 monitor out of operation 8/23/18. Monitor in operation on 09/19/18. During this time, all material had been removed from the c~.
@ENCOUSA
URENCO USA: Report of Radioactivity in Effluents: Liquid & Air: July 2018 - December 2018 There were no releases to the public during the reporting period that exceeded regulatory requirements.
Detected isotopic uranium activities were comparable to pre-operational activities. No dose assessment was performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points were acceptable. The potential maximum doses directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentrations.
In liquid effluent, the concentrations of isotopic uranium was either below the Minimum Detectable Concentration (MDC) or less that 10% of values listed in 10 CFR 20, Appendix 8, Table 3, "Releases to Sewers" (Table 1-1).
In gaseous effluent, the gross uranium activity was either below the Minimum Detectable Activity (MDA) or less than 10% of values Usted in 1 O CFR 20, Appendix 8, Table 2, "Effluent Concentrations - Class D Air" for U234, U235, and U238.
The concentrations of isotopic uranium in gaseous effluent was either below the Minimum Detectable Concentration (MDC) or less that 10% of values listed in 10 CFR 20.1301, 10 CFR 20.1302, and 1 O CFR 20.1101 ( d), as described in NRC Regulatory Guide 4.20 "Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors" dated December 1996.
LIST OF TABLES Table No.
1-1 1-2 1-3 1-4 1-5 1-6 1-7 Title Lift Station 1 Wastewater Effluent - Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1001 (SBM 1001) Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA1 & 1001-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1003 (SBM 1003) Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1MA1 & 1003-562-1MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Separations Building Module-1005 (SBM 1005) Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1 MA1 & 1005-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA 1 & 1100-562-1 MA2 - Gross Alpha &
Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA 1 & 1100-562-2MA2 - Gross Alpha &
Gross Beta, and Radionuclides Quarters 3 & 4, 2018 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF) Exhaust Filtration System Gaseous Effluent - 1300-562-1 MA 1 Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2018
~RENCOUSA
TABLE 1-1 Lift Station 1 Wastewater Effluent - Radionuclides, Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Lift Station 1 Wastewater Bfluent-.Radionuclides Total Counting Quantity
% ofTable 3 of AppendixB Radionuclide Sample Date Sample Period Time Results Uncertainty Total Flow*.
Released to 1 O CFR 20 Values" (Datemme)
(days)
(µCi/ml)
(µCi/ml)
(gallons/day)
(Ci)
Monthly Average Release to Sewers Lift Station 1 - July - December 2018 Uranium - 233/234 2.10E-10 5.00E-11 13,000 Result Below LLD Result Below LLD Uranium - 235/236 10/8/2018 9:20 07/01/18 -12/31/18 183 0.00800 0.00800 13,000 Result Below LLD Result Below LLD Uranium - 238 2.70E-10 5.00E-11 13,000 Result Below LLD Result Below LLD Lift Station 1 Duplicate - July - December 2018 Uranium - 233i234 1.40E-10 3.00E-11 13,000 Result Below LLD Result Below LLD Uranium - 235/236 10/8/2018 9:25 07/01/18-12/31/18 183 0.00800 0.00800 13,000 Result Below LLD
. Result Below LLD Uranium - 238 9.00E-11 3.00E-11 13,000 Result Below LLD Result Below LLD Notes:
- 1. * = Table 3.4-4 "Anticipated Normal Plant Water Consumption" from the Environmental Report, Rev. 19, lists 'Total Personnel Water Use" as approximately 13,000 gallons per day.
- 2. µCi/ml = microCuries per milliliter.
3.. Radionuclides analyzed using method EICHROM AC01 by Cardinal Laboratories of Hobbs, NM (subcontracted to Radiation Safety Engineering of Chandler, AZ.).
- 4. Quantity released is calculated if the result equals or exceeds the LLD. Facility-required lower level of detection (LLD) is 3.0E-9 uCi/mL.
TABLE 1-2 Separations Building Module-1001 (SBM 1001 ): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1 MA 1 & 1001-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico.
Sample Gross MDA/
Inst. Unc.
Total Flow Quantity
% ofTable2 Sar,nple ID Sample Period Analyte Result MDC Released Appendix B
- Date
µCi/ml
µCi/ml
µCi/ml m3 Ci 10CFR 20 1001-562-1MA1 10015621MA1 070318 8/1/18 7/3/18 - 8/1/18 6.25E-17 1.67E-16 6.31E-08 4.39E+05
<MDA
<MDA 10015621MA1 080118 9/3/18 8/1/18-9/3/18 5.44E-17 1.46E-16 6.31E-08 5.20E+05
<MDA
<MDA 10015621MA1 090418 10/1/18 9/3/18 - 10/1/18 Gross O.OOE+OO 1.85E-16 O.OOE+OO 4.10E+05
<MDA
<MDA 10015621MA1100118 11/2/18 10/1/18-11/2/18 Alpha
-2.17E-18 1.54E-16 6.31E-08 4.82E+05
<MDA
<MDA 10015621MA1110218 12/3/18 11 /2/18-12/3/18 1.14E-17 1.55E-17 8.56E-08 5.01E+05
<MDA
<MDA 10015621MA1120318 1/3/19 12/3/18 - 1/3/19 6.36E-17 1.67E-16 6.31E-08 5.04E+05
<MDA
<MDA 10015621MA1 070318 8/1/18 7/3/18 - 8/1/18 6.03E-15 3.47E-15 1.44E-06 4.39E+05 2.65E-09 0.201%
10015621MA1 080118 9/3/18 8/1/18-9/3/18 4.53E-15 3.02E-15 1.38E-06 5.20E+05 2.35E-09 0.151%
10015621MA1 090418 10/1/18 9/3/18-10/1/18 Gross 2.76E-15 3.83E-15 1.15E-06 4.10E+05
<MDA
<MDA 10015621MA1100118 11/2/18 10/1/18-11/2/18 Beta 6.15E-15 3.07E-15 1.62E-06 4.82E+05 2.96E-09 0.205%
10015621MA1110218 12/3/18 11/2/18-12/3/18 6.16E-16 3.10E-16 1.49E-06 5.01E+05 3.08E-10 0.021%
10015621MA1120318 1/3/19 12/3/18-1/3/19 4.98E-15 3.35E-15 1.35E-06 5.04E+05 2.51E-09 0.166%
1001-562-1 MA2 10015621MA2 070318A 8/1/18 6/1/18 - 8/1/18 1.92E-16 2.58E-16 9:01E-08 9.54E+05
<MDA
<MDA 10015621MA2 080118 9/3/18 8/1/18-9/3/18 1.48E-16 1.99E-16 9.01E-08 5.38E+05
<MDA
<MDA 10015621MA2 090418 10/1/18 9/3/18-10/1/18, Gross 6.31E-18 1.69E-17 6.31E-08 4.31E+05
<MDA
<MDA 10015621MA2100118 11/2/18 10/1/18-11/2/18 Alpha O.OOE+OO 1.41E-16 O.OOE+OO 5.04E+05
<MDA
<MDA 10015621MA2110218 12/3/18 11/2/18-,12/3/18 O.OOE+OO 1.41E-16 O.OOE+OO 5.14E+05
<MDA
<MDA 10015621MA2 120318 1/3/19 12/3/18 - 1/3/19 1.04E-16 1.42E-16 8.56E-08 5.17E+05
<MDA
<MDA 10015621MA2 070318A 8/1/18 6/1/18 - 8/1/18 5.76E-15 5.34E-15 1.26E-06 9.54E+05 5.49E-09 0.192%
10015621MA2 080118 9/3/18 8/1/18 - 9/3/18 6.67E-15 4.12E-15 1.41E-06 5.38E+05 3.59E-09 0.222%
10015621MA2 090418 10/1/18 9/3/18-10/1/18 Gross 3.99E-16 3.50E-16 1.27E-06 4.31E+05 1.72E-10 0.013%
10015621MA2100118 11/2/18 10/1/18-11/2/18 Beta 5.38E-15 2.81 E-15 1.47E-06 5.04E+05 2.71E-09 0.179%
10015621 MA2 110218 12/3/18 11 /2/18-12/3/18 4.39E-15 2.81E-15 1.37E-06 5.14E+05 2.26E-09 0.146%
10015621MA2 120318 1/3/18 12/3/18 - 1/3/19 4.96E-15 2.84E-15 1.49E-06 5.17E+05 2.56E-09 0.165%
Quantity
% ofTable2 Radionuclide Sample Result 2crTPU 1cr TPU MDC Total Flow Sample Period Released Appendix !3 (Isotopic Uraniun:i (U))
Date
µCi/ml
(µCi/ml)
µCi/ml (1,1Ci/ml) m3 Ci 10CFR20 1001-562-1MA1 U0233/234 1.67E-16 8.83E-17 8.91E-17 6.60E-17 0.00 0.01%
U-235/236 3 Qtr.
10/1/18 7/3/18-10/1/18 7.92E-17 6.59E-17 6.61E-17 5.67E-17 1.37E+06 0.00 0.00%
LJ,238 1.88E-16 9.34E-17 9.43E-17 6.57E-17 0.00 0.01%
U-233/234 2.68E-17 1.63E-17 1.64E-17 1.60E-17 1.49E+06 0.00 0.00%
U-235/236 4 Qtr.
1/3/19 10/1/18-1/3/19 2.59E-17 1.78E-17 1.79E-17 1.84E-17 0.00 0.00%
U-238 3.03E-17 1.74E-17 1.75E-17 1.69E-17 0.00 0.00%
1001-562-1MA2 U-233/234 1.78E-17 1.44E-17 1.45E-17 1.61E-17 0.00 0.00%
3 Qtr.
10/1/18 6/1/18-10/1/18 1.53E-17 1.53E-17 1.51E-17 1.92E+06 U-235/236 1.78E-17 0.00 0.00%
U-238 3.18E-17 1.83E-17 1.84E-17 1.34E-17 0.00 0.00%
U-233/234 1.84E-16 7.38E-17 7.49E-17 4.22E-17 0.00 0.01%
4 Qtr.
1/3/19 10/1/18-1/3/19 5.50E-17 4.57E-17 4.59E-17 4.91E-17 1.53E+06 U-235/236 0.00 0.00%
U-238 7.13E-17 4.64E-17 4.66E-17 4.20E-17 0.00 0.00%
Notes:
A. 10015621MA2 070318, filter was put on 6/1/18 and removed 8/1/18. Monitor out of operation on 6/10/18 due to faulty pump. Monitor in operation on 7/19/18. Filter left on for duration.
~ENCOUSA
TABLE 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA 1 &
1003-562-1 MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico
, Sample Gross MDA/
Inst. Unc.
Total Flow Quantity Sample ID Date Sam-pie Period Analyte Result MDC
µCi/ml m3 Released
µCi/ml
µCi/ml Ci 1003-562-1 MA1 10035621MA1 070318 08/01/18 7/3/18 - 8/1/18
-3.33E-01 1.34E-16 6.31E-08 4.q3E+05
<MDA 10035621MA1 080118A 11/02/18 8/1/18 - 11/2/18 Gross 6.20E-17 4.23E-17 1.48E+06 Alpha 1.22E-07 9.15E-11 10035621MA11102188 1/03/18 11/2/18 - 1/3/19 2.35E-17 6.17E-17 6.31E-08 1.05E+06
<MDA 10035621MA1 070318 08/01/18 7/3/18 - 8/1/18 4.33E-15 2.78E-15 1.68E-06 4.63E+05 2.00E-09 10035621MA1 080118A 11/02/18 8/1/18 - 11/2/18 Gross 1.30E-15 8.75E-16 1.37E-06 1.48E+06 Beta 1.91E-09 10035621MA11102188 1/03/18 11/2/18-1/3/19 1.37E-15 1.23E-15 1.32E-06 1.05E+06 1.43E-09 1003-562-1 MA2 10035621MA2 070318 08/01/18 7/3/18-8/1/18 Gross
-8.24E-18 1.29E-16 9.01E-08 4.93E+05
<MDA 10035621MA2 080118c 08/16/18 8/1/18
- 8/16/18 Alpha O.OOE+OO 2.67E-16 O.OOE+OO 2.48E+05
<MDA 10035621MA2 070318 08/01/18 7/3/18 - 8/1/18 Gross 2.62E-15 2.67E-15 1.64E-06 4.93E+05
<MDA 10035621MA2 080118c 08/16/18 8/1/18-8/16/18 Beta 6.96E-15 5.52E-15 1.31E-06 2.48E+05 1.73E-09 Radionuclide Sample Result 2crTPU 1crTPU MDC Total Flow Quantity (Isotopic Uranium (U))
Date Sample Period
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Released Ci 1003-562-1MA1 U-233/234 8.69E-17 4.61E-17 4.65E-17 4.70E-17 1.94E+06 0.00 U-235/236 3 Qtr.
11/2/2018 7/3/18-11/2/18 6.86E-17 4.24E-17 4.27E-17 3.68E-17 0.00 U-238 4.70E-17 3.29E-17 3.31E-17 3.53E-17 0.00 U-233/234 1.08E-16 6.36E-17 6.41E-17 4.42E-17 1.05E+06 0.00 U-235/236 4 Qtr.
1/3/2019 11/2/18-1/3/19 7.40E-17 5.98E-17 6.01E-17 5.98E-17 0.00 U-238 1.39E-16 7.35E-17 7.42E-17 5.51E-17 0.00 1003-562-1 MA2 U-233/234 2.74E-16 1.19E-16 1.20E-16 6:93E-17 0.00 3 Qtr.
8/16/18 8/1/18-8/16/18 1.39E+06 U-235/236 7.32E-17 6.70E-17 6.72E-17 6.33E-17 0.00 U-238 1.96E-16 1.01E-16 1.02E-16 7.34E-17 0.00 Notes:
A.
10035621MA1 080118, filter was put on 8/1/18 and removed 11/2/18.
B.
10035621 MA1 110218, filter was put on 11/2/18 and removed 1/3/19.
C.
Redundant monitor out of operation on 8/15/18 due to faulty pump.
@_iENCO USA
% ofTable2 Appendix B 10CFR20
<MDA 0.002%
<MDA 0.144%
0.043%
0.046%
<MDA
<MDA
<MDA 0.232%
% of Table 2 Appendix B 10CFR20 0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.01%
0.00%
0.01%
TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 &
1005-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample Gross MDA/
Inst. Unc.
Total Flow
'buantity Sample ID Sample Period Analyte Result MDC Released Date
µCi/rill
µCi/ml
µCi/ml m3 Ci 1005-562-1 MA 1 10055621MA1 070318 8/1/18 7/3/18
- 8/1/18 0.00E+OO 1.71E-16 O.OOE+OO 8.28E+05
<MDA 10055621MA1 080118 9/3/18 8/1/18 - 9/3/18 1.11E-16 1.48E-16 9.01E-08 9.46E+05
<MDA 10055621MA1 090418 10/1/18 9/3/18 -10/1/18 Gross 6.84E-17 1.83E-16 6.31E-08 7.79E+05
<MDA 10055621MA1100118 11/2/18 10/1 /18-11 /2/18 Alpha 5.79E-17 1.52E-16 6.31E-08 9.27E+05
<MDA 10055621 MA1 110218 12/3/18 11 /2/18-12/3/18 1.17E-16 1.60E-16 8.56E-08 8.97E+05
<MDA 10055621MA1120318 1/3/19 12/3/18 - 1/3/19
-6.19E-17 1.63E-16 2.05E-10 8.95E+05
<MDA 10055621MA1 070318 8/1/18 7/3/18
- 8/1/18 5.10E-15 3.54E-15 1.36E-06 8.28E+05 4.22E-09 10055621MA1 080118 9/3/18 8/1/18 - 9/3/18 2.95E-15 3.07E-15 1.23E-06 9.46E+05
<MDA 10055621MA1 090418 10/1/18 9/3/18-10/1/18 Gross 4.78E-15 3.79E-15 1.31E-06 7.79E+05 3.72E-09 10055621MA1100118 11/2/18 10/1/18-11/2/18 Beta 6.05E-15 3.05E-15 1.49E-06 9.27E+05 5.60E-09 10055621MA1 110218 12/3/18 11 /2/18-12/3/18 4.53E-15 3.19E-15 1.33E-06 8.97E+05 4.06E-09 10055621MA1120318 1/3/19 12/3/18 - 1/3/19 5.35E-15 3.25E-15 1.53E-06 8.95E+05 4.79E-09 1005-562-1 MA2 10055621MA2 070318 8/1/18 7/3/18 - 8/1/18 1.33E-16 1.78E-16 9.01E-08 8.44E+05
<MDA 10055621MA2 080118 9/3/18 8/1/18 - 9/3/18 O.OOE+OO 1.54E-16 O.OOE+OO 9.88E+05
<MDA 10055621MA2 090418 10/1/18 9/3/18-10/1/18 Gross 2.82E-16 1.92E-16 1.26E-07 7.93E+05 2.24E-10 10055621 MA2 100118 11/2/18 10/1/18-11/2/18 Alpha 1.78E-16 1.60E-16 1.08E-07 9.35E+05 1.66E-10 10055621MA2 110218 12/3/18 11/2/18-12/3/18 0.00E+OO 1.63E-16 O.OOE+OO 9.13E+05
<MDA 10055621MA2 120318 1/3/19 12/3/18 - 1/3/19 6.37E-17 1.68E-16 6.31E-08 8.97E+05
<MDA 10055621MA2 070318 8/1/18 7/3/18-8/1/18 7.52E-15 3.68E-15 1.51E-06 8.44E+05 6.34E-09 10055621 MA2 080118 9/3/18 8/1/18 - 9/3/18 3.63E-15 3.18E-15 1.27E-06 9.88E+05 3.59E-09 10055621MA2 090418 10/1/18 9/3/18 -10/1/18 Gross 4.06E-15 3.98E-15 1.24E-06 7.93E+05 3.22E-09 10055621 MA2 100118 11/2/18 10/1/18-11/2/18 Beta 2.49E-15 3.19E-15 1.13E-06 9.35E+05
<MDA 10055621 MA2 110218 12/3/18 11 /2/18-12/3/18 7.62E-15 3.25E-15 1.58E-06 9.13E+05 6.96E-09 10055621MA2 120318 1/3/19 12/3/18 - 1/3/19 7.61E-15 3.35E-15 1.56E-06 8.97E+05 6.83E-09 Radionuclide Sample Result 2cr TPU
,1 cr TPU MDC Total Flow Quantity,:
Sample Period Released (Isotopic Uranium (U)) I D_ate
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Ci 1005-562-1MA1 U-233/234 2.18E-16 9.35E-17 9.48E-17 5.09E-17 2.55E+06 0.00 U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 7.18E-17 6.24E-17 6.26E-17 7.18E-17 0.00 U-238 1.24E-16 6.93E-17 6.99E-17 4.03E-17 0.00 U-233/234 2.27E-16 8.80E-17 8.95E-17 5.10E-10 2.72E+06
<MDC U-235/236 4Qtr.
1/3/2019 10/1/18-1/3/19 1.10E-16 6.85E-17 6.90E-17 5.99E-17 0.00 U-238 1.60E-16 7.21 E-17 7.30E-17 3.37E-17 4.35E-10 1005-562-1 MA2 U-233/234 9.46E-17 7.80E-17 7.83E-17 9.52E-17
<MDC U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 3.31E-17 3.31E-17 9.02E-17 2.62E+06 5.12E-18
<MDC U-238 1.12E-16 7.70E-17 7.74E-17 6.17E-17 0.00 U-233/234 1.58E-16 7.99E-17 8.07E-17 5.46E-17 4.34E-10 U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 8.16E-17 6.25E-17 6.28E-17 4.99E-17 2.75E+06 0.00 U-238 2.03E-16 9.06E-17 9.18E-17 5.78E-17 5.57E-10
-~ENCOUSA
% ofTable2 Appendix B 10CFR20
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA 0.170%
<MDA 0.159%
0.202%
0.151%
0.178%
<MDA
<MDA 0.009%
0.006%
<MDA
<MDA 0.251%
0.121%
0.135%
<MDA 0.254%
0.254%
% of Table 2 Appendix B 10CFR 20 0.01%
0.00%
0.00%
<MDC 0.00%
0.005%
<MDC
<MDC 0.00%
0.005%
0.00%
0.007%
TABLE 1-5 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1 MA 1 &
1100-562-1 MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample Gross MDA/
Inst. Unc.
Total Flow Quantity
% ofTable2 Sample ID Sample Period Analyte Result MDC Released Appendix B Date
µCi/ml
µCi/ml
µCi/ml m3 Ci 10CFR 20 1100-562-1MA1 11005621MA1 070318 8/1/18 7/3/18-8/1/18 O.OOE+OO 1.82E-16 O.OOE+OO 4.34E+05
<MDA
<MDA 11005621MA1 080118 9/3/18 8/1/18 - 9/3/18 1.31E-16 3.51E-16 6.31E-08 1.22E+05
<MDA
<MDA 11005621MA1 090418 10/1/18 9/3/18 - 10/1/18 Gross 1.63E-16 2.19E-16 9.01E-08 5.84E+04
<MDA
<MDA 11005621MA1100118
- 11/2/18 10/1/18 - 11/2/18 Alpha O.OOE+OO 1.81E-16 O.OOE+OO 4.29E+04
<MDA
<MDA 11005621MA1110218 12/3/18 11/2/18 - 12/3/18 7.87E-17 2.07E-16 6.31 E-08 O.OOE+OO
<MDA
<MDA 11005621MA1 120318 1/3/19 12/3/18 - 1/3/19 O.OOE+OO 1.60E-16 O.OOE+OO 6.19E+05
<MDA
<MDA t1005621MA1 070318 8/1/18 7/3/18 - 8/1/18 5.34E-15 3.77E-15 1.41E-06 4.34E+05 2.32E-09 0.178%
11005621MA1 080118 9/3/18 8/1 /18 - 9/3/18 1.40E-14 7.28E-15 1.49E-06 1.22E+05 1.71E-09 0.466%
11005621MA1 090418 10/1/18 9/3/18-10/1/18 Gross 5.44E-15 4.53E-15 1.29E-06 5.84E+04 3.18E-10 0.181%
11005621MA1100118 11/2/18 10/1/18-11/2/18 Beta 7.43E-15 3.61E-15 1.51E-06 4.29E+04 3.19E-10 0.248%
11005621MA1110218 12/3/18 11/2/18 - 12/3/18 6.75E-15 4.14E-15 1.39E-06 O.OOE+OO O.OOE+OO 0.225%
11005621MA1120318 1/3/19 12/3/18-1/3/19 6.03E-15 3.19E-15 1.53E-06 6.19E+05 3.73E-09 0.201%
1100-562-1MA2 11005621MA2 070318 8/1/18 7/3/1~ - 8/1/18 6.19E-17 1.66E-16 6.31E-08 5.73E+05
<MDA
<MDA 11005621MA2 080118 9/3/18 8/1 /18 - 9/3/18 1.34E-16 1.80E-16 9.01E-08 1.22E+05
<MDA
<MDA 11005621MA2 090418 10/1/18 9/3/18-10/1/18 Gross 8.62E-17 2.31E-16 6.31E-08 6.70E+01
<MDA
<MOA 11005621MA2100118 11/2/18 10/1/18-11/2/18 Alpha
-2.78E-18 1.97E-16 6.31E-08 2.68E+01
<MDA
<MDA 11005621 MA2 110218 12/3/18 11/2/18-12/3/18 2.78E-16 1.86E-16 1.22E-07 6.05E+03 1.68E-12 0.009%
11005621MA2 120318 1/3/19 12/3/18 - 1/3/19 O.OOE+OO 1.55E-16 O.OOE+OO 5.60E+05
<MDA
<MDA 11005621MA2 070318 8/1/18 7/3/18-8/1/18 4.32E-15 3.43E-15 1.31E-06 5.73E+05 2.48E-09 0.144%
11005621MA2 080118 9/3/18 8/1/18 - 9/3/18 6.17E-15 3.72E-15 1.47E-06 1.22E+05 7.54E-10 0.206%
11005621 MA2 090418 10/1/18 9/3/18 -10/1/18 Gross 4.59E-15 4.78E-15 1.23E-06 6.70E+01
<MDA
<MDA 11005621 MA2 100118 11/2/18 10/1/18 - 11/2/18 Beta 8.18E-15 3.95E-15 1.64E-06 2.68E+01 2.19E-13 0.273%
11005621MA2 110218 12/3/18 11/2/18-12/3/18 7.66E-15 3.72E-15 1.51 E-06 6.05E+03 4.64E-11 0.255%
11005621MA2120318 1/3/19 12/3/18 - 1/3/19 1.98E-15 3.10E-15 1.08E-06 5.60E+05
<MDA
<MDA Radionuclide sa*mple Result 2aTPU 1aTPU MDC Total Flow
,Quantity
% ofTable2 Sample Period Released Appendix B (Isotopic Uranium (U))
Date
µCi/ml
(µCi/ml)
µCi/ml
(µCi/ml) m3 Ci 10CFRZO 1100-562-1 MA1 U-233/234 2.30E-14 4.14E-15 4.46E-15 2.67E-16 0.00 0.77%,
U-235/236 3 Qtr..
10/3/2018 7/3/18-10/1/18 4.67E-16 3.51E-16 3.53E-16 3.50E-16 6.14E+05 0.00 0.02%
U-238 6.44E-16 3.61E-16 3.64E-16 2.25E-16 0.00 0.02%
U-233/234 1.17E-16 8.78E-17 8.82E-17 8.19E-17 0.00 0.00%
U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 3.85E-17 6.55E-17 6.55E-17 1.15E-16 6.62E+05
<MDC
<MDC U-238 1.84E-16 1.07E-16 1.08E-16 6.48E-17 0.00 0.01%
1100-562-1 MA2 U-233/234 1.61E-16 8.50E-17 8.58E-17 5.26E-17 0.00 0.01%
U-235/236 3 Qtr.
10/3/2018 7/3/18-10/1/18 1.04E-16 7.61E-17 7.65E-17 6.49E-17 6.95E+05 0.00 0.00%
U-238 8.21E-17 6.16E-17 6.18E-17 5.75E-17 0.00 0.00%
U-233/234 7.71E-17 6.35E-17 6.37E-17 7.76E-17
<MDC
<MDC U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 9.53E-17 7.32E-17 7.36E-17 7.35E-17 5.66E+05 0.00 0.00%
U-238 1.44E-16 7.84E-17 7.90E-17 5.03E-17 0.00 0.00%
TABLE 1-6 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 &
1100-562-2MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Gross MDA/
Quantity
% ofTable2 Sample ID Sample Sample Period Analyte Result MDC Inst. Unc.
Total Flow Released Appendix B Date
µCi/ml
µCi/ml
µCi/ml m3 Ci 10CFR20 1100-562-2MA 1 11005622MA1 070318 8/1/18 7/3/18-8/1/18 2.68E-16 1.46E-16 1.40E-07 2.92E+07 7.83E-09 0.009%
11005622MA1 080118 9/3/18 8/1 /18 - 9/3/18 2.90E-16 1.31E-16 1.53E-.07 3.21E+07 9.32E-09 0.010%
11005622MA 1 090418 10/1/18 9/3/18 - 10/1 /18 Gross 3.75E-16 1.58E-16 1.67E-07 2.71E+07 1.01E-08 0.012%
11005622MA 1 100118 11/2/18 10/1/18-11/2/18 Alpha 2.47E-16 1.34E-16 1.40E-07 3.27E+07 8.06E-09 0.008%
11005622MA1110218 12/3/18 11/2/18-12/3/18 5.09E-17 1.34E-16 6.31E-08 3.05E+07
<MDA
<MDA 11005622MA 1 120318 1/3/19 12/3/18 - 1/3/19 1.53E-16 1.37E-16 1.08E-07 3.13E+07 4.79E-09 0.005%
11005622MA1 070318
- 8/1/18 7/3/18 - 8/1/18 4.16E-15 3.02E-15 1.34E-06 2.92E+07
.1.22E-07 0.139%
11005622MA1 080118 9/3/18 8/1/18 - 9/3/18.
2.87E-15 2.71E-15 1.32E-06 3.21E+07 9.22E-08 0.096%
11005622MA1 090418 10/1/18 9/3/18-10/1/18 Gross 3.13E-15 3.27E-15 1.33E-06 2.71E+07
<MDA
<MDA 11005622MA1100118 11/2/18 10/1/18-11/2/18 Beta 5.69E-17 2.68E-15 1.53E-06 3.27E+07
<MDA
<MDA 11005622MA1110218 12/3/18 11/2/18-12/3/18 3.98E-15 2.68E-15 1.35E-06 3.05E+07 1.22E-07 0.133%
11005622MA1120318 1/3/19 12/3/18 - 1/3/19 7.00E-15 2.74E-15 1.63E-06 3.13E+07 2.19E-07 0.233%
1100-562-2MA2 11005622MA2 070318 8/1/18 7/3/18 - 8/1/18 2.34E-16 1.59E-16 1.26E-07 3.11E+07 7.27E-09 0.008%
11005622MA2 080118 9/3/18 8/1/18 - 9/3/18 O.OOE:t-00 1.40E-16 O.OOE+OO 3.40E+07
<MDA
<MDA 11005622MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 1.29E-16 1.79E-16 1.08E-07 2.84E+07
<MDA
<MDA 11005622MA2 100118 11/2/18 10/1/18-11/2/18 Alpha 9.89E-17 8.88E-17 1.08E-07 6.19E+07 6.12E-09 0.003%
11005622MA2 110218 12/3/18 11/2/18-12/3/18 1.49E-16 1.34E-16 1.08E-07 3.27E+07 4.88E-09 0.005%
11005622MA2 120318 1/3/19 12/3/18-1/3/19 1.64E-15 4.31E-15 6.31E-08 3.21E+07
<MDA
<MDA 11005622MA2 070318 8/1/18 7/3/18 - 8/1/18 3.89E-15 3.30E-15 1.35E-06 3.11E+07 1.21E-07 0.130%
11005622MA2 080118 9/3/18 8/1 /18 - 9/3/18 3.30E~15 2.89E-15 1.27E-06 3.40E+07 1.12E-07 0.110%
11005622MA2 090418 10/1/18 9/3/18 - 10/1/18 Gross 5.16E-15 3.71E-15 1.46E-06 2.84E+07 1.46E-.07 0.172%
11005622MA2 100118 11/2/18 10/1/18-11/2/18 Beta 3.02E-15 1.78E-15 1.41 E-06 6.19E+07 1.87E-07 0.101%
11005622MA2110218 12/3/18 11/2/18-12/3/18 4.94E-15 2.68E-15 1.45E-06 3.27E+07 1.61E-07 0.165%
11005622MA2120318 1/3/19 12/3/18 - 1/3/19 1.53E-13 8.62E-14 1.43E-06 3.21E+07 4.91E-06 5.091%
Radionuclide
- Sample Result 2cr TPU 1cr TPU MDC Total Flow Quantity
%ofTable2 Sample Period Released Appendix B.
(Isotopic Uranium (U))
Date
µCi/ml
.(µ~i/ml)
µCi/ml
(µCi/ml) m3 Ci 10CFR20 1100-562-2MA1 U-233/234 1.99E-16 8.05E-17 8.17E-17 5.36E-17 1.76E,08 0.007%
U-235/236 3 Qtr.
10/1/2018 7/3/18° 10/1/18 2.79E-18 2.76E-17 2.76E-17 6.83E-17 8.84E+07
<MDC
<MDC U-238 1.95E-16 7.86E-17 7.98E-17 4.73E-17
~1.72E-08 0.007%
U-233/234 1.47E-14 2.81 E-15 3.00E-15 1.82E-16 0.00 0.490%
U-235/236 4Qtr.
1/3/2019 10/1/18-1/3/19 5.56E-16 3.15E-16 3.18E-16 2.38E-16 9.46E+07 0.00 0.019%
U-238 1.49E-16 1.43E-16 1.44E-16 1.53E-16
<MDC
<MDC 1100-562-2MA2 U-233/234 2.18E-16 8.82E-17 8.96E-17 4.85E-17 2.04E-08 0.007%
U-235/236 3 Qtr.
10/1/2018 7/3/18-10/1/18 1.02E-16 6.65E-17 6.69E-17 5.07E-17 9.35E+07 0.00 0.003%
U-238 1.92E-16 8.24E-17 8.35E-17 4.49E-17 1.79E-08 0.006%
U-233/234 3.08E-16 1.48E-16 1.50E-16 8.33E-17 0.00 0.010%
U-235/236 4 Qtr.
1/3/2019 10/1/18-1/3/19 1.22E-16 1.04E-16 1.05E-16 1.03E-16 1.27E+08 0.00 0.004%
U-238 1.65E-16 1.09E-16 1.10E-16 9.10E-17 0.00 0.006%
~~ENCOUSA
TABLE 1-7 Centrifuge Test and Post Mortem Facilities-1300 (CTPMF): Local Extract Exhaust Gaseous Effluent Vent System, 1300-562-1 MA 1, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2018 URENCO USA Lea County, New Mexico Sample.
'Gross I MDA/
Inst. One;:.
Total Flow*
Quantity
% ofTable2 S~mple ID Sample Period Analyte Result MDC Released Appenqix,8 Date
µCi/ml
- µCi/m!
µCi/ml m3
- ci 10CFR20 1300-562-1 MA 1 13005621MA1 070518 8/1/18 7/5/18 - 8/1/18 6.19E-17
- 1.66E-16 6.31E-08 1.14E+07.
<MDA
<MDA 13005621MA1 080118 10/1/18 8/1/18
- 10/1/18 9.13E-17 1.22E-16 9.01E-08 2.64E+07
<MDA
<MDA 13005621MA1100118 11/5/18 10/1/18-11 /5/18 Gross 4.35E-17 1.17E-16 1.49E+07 Alpha 6.31E-08
<MDA
<MDA 13005621MA1 110218 12/5/18 11/2/1 -12/5/18 1.64E-16 1.47E-16 1.08E-07 1.27E+07 2.09E.09 0.005%
13005621MA1 120518 1/3/19 12/5/18-1/3/19 1.59E-16 1.43E-16 1.08E-07 1.24E+07 1.98E-09 0.005%
130P5621MA1 07Q518 8/1/18
- 7/5/18 - 8/1/18 3.09E-15 3.43E-15 1.21.E-06 1.14E+07
<MDA
<MDA 13005621MA1 080118 10/1118 8/1/18-10/1/18 4.57E-15 2.54E-15 1.46E-06 2.64E+07 1.21E-07 0.152%
13005621MA1100118 11/5/18 10/1/18-11/5/18 Gross 4.06E-15 Beta 2.41E-15 1.43E-06 1.49E+07 6.05E-08 0.135%
13005621MA1110218 12/5/18 11/2/1
- 12/5/18 6.25E-15 2.94E-15 1.53E-06 1.27E+07 7.97E-08 0.208%
13005621 MA1 120518 1/3/19 12/5/18 - 1/3/19 4.66E-15 2.86E-15 1.39E-06 1.24E+07 5.78E-08 0.155%
Radionuclide Sample Result 2crTPU icrTPU MDC Total Flow. Quantity
- % of Table 2
- Sample _Period Released* Appendix,, B.
(lsotopip Uranium (U))
Date
µQi/ml*
(µCi/ml) 1 * µCi/ml.
(µCi/ml) m3 Ci.
10GFR 20 1300-562-1 MA1 U0 233/234 2.16E-16 1.05E-16 1.06E-16 6.49E-17.
3.78E+07 0.00 0.01%
U-235/236 3Qtr.
10/1/2018 7/5/1~10/1/18 1.22E-16 9.05E-17 9.09E-17 9.15E-17 0.00 0.00%
U-238 1.74E-16 9.54E~17 9;62E-17 7.38E-17' 0.00 0.01%
U-233/234 7.56E-17 5.30E-17 5.33E-17 5.68E-17 0.00 0.00%
U-235/236 4 Qtr.
1/3/2018 10/1/18-1/3/19 3.25E-17 4.45E-17 4.46E-1.7 7.24E-17 4.01E+07
<MDC
<MDC U-238 1.35E-16 6.76E-17 6.83E-17 5.01E-17 0.00 0.00%
Notes:
A.
13005621 MA1 monitor out of operation 8/23/18. Monitor in operation on 09/19/18. During this time, all material had been removed from the CAB.
ti~ENCOUSA