Attachment 3 CALCULATION NO.:
M1418 REVISION NO.:
1 ECNO.:
0000081416 PAGE 1 OF 1 Estimate of Initial Temperature Difference Between Cladding and Surrounding Air With the adiabatic assumption and no air cooling of assemblies (Assumption 4.5) the cylindrical wall heat conduction equation was used to estimate the temperature difference between the cladding and surrounding air for a single fuel rod. The temperature difference is calculated for the bounding element decay heat at 10 months divided by the total number of heated rods (92).
This estimated a bounding temperature difference that would only reduce over longer decay periods or if any credit was taken for convective cooling of the rod. The 1-D cylindrical wall heat conduction equation from Reference 111.7 is:
2rr x L (m) x k (b) x t:.T(K) q ( watts) =
( ) I ln(2 m I r1 (m))
Where:
L = the active length of the fuel from Table 2 = 145.24 in= 3.689 m k = the thermal conductivity of air at 300K (-80°F) from Reference 111.7 is 26.3 x10-3 W/m-K t:.T(K) = the estimated temperature difference between the surface of the cladding and the surrounding air (to be calculated) r1 = the outer radius of the cladding from Table 2 = 0.404 in / 2 = 0.202 in = 0.00513 m r2 = half the pitch between fuel rods from Table 2 = 0.510 in/ 2 = 0.255 in = 0.00648 m; and q = the decay heat at 10 months in a single fuel rod= 1.04 x 104 W/MTU (Input 3.4) x 0.1814 MTU (Input 3.4) + 92 heated rods (Table 2) = 20.5 watts per rod Solving the equation above for t:.T(K) using the referenced values results in the temperature difference of:
20.5 (W) X In( 0.00648(m) /
)
t:.T(K) =
/O.OOS~(m) = 7.86K -14.1°F 2rr x 3.689 (m) x 26.3 x 10-3 Cm _ K)
EN-DC-126 REV 8
Parameter Value Unit Decay Heat 6.44E+03 BTU/Hr Mass U02 450.136 lbm Mass Zirc (Fuel) 91.858 lbm Mass Zirc 135.678 lbm (Fuel+Channel)
Starting Temp 140 "F Credit Temp 580 "F 10 hour1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> Temp 895.05 *c Elapsed Time Time Step Initial Temp hr hr "F
0 0.025 140 0.025 0.025 144.87 0.05 0.025 149.73 0.075 0.025 154.57 0.1 0.025 159.40 0.125 0.025 164.21 0.15 0.025 169.01 0.175 0.025 173.79 0.2 0.025 178.57 0.225 0.025 183.33 0.25 0.025 188.07 0.275 0.025 192.81 Reference Design Input 3.4 Section 6.0 Section 6.0 Section 6.0 Assumption 4.2 Assumption 4.8 Calculated Decay Heat Mass U02 CpU02 Mass Zirc BTU/hr lbm BTU/lbm-°F lbm 6.44E+03 450.136 0.0593 91.858 6.44E+03 450.136 0.0595 91.858 6.44E+03 450.136 0.0597 91.858 6.44E+03 450.136 0.0599 91.858 6.44E+03 450.136 0.0601 91.858 6.44E+03 450.136 0.0603 91.858 6.44E+03 450.136 0.0605 91.858 6.44E+03 450.136 0.0607 91.858 6.44E+03 450.136 0.0609 91.858 6.44E+03 450.136 0.0610 91.858 6.44E+03 450.136 0.0612 91.858 6.44E+03 450.136 0.0614 91.858 Cp Zirc
~T BTU/lbm-°F
- F 0.0688 4.87 0.0689 4.86 0.0690 4.84 0.0692 4.83 0.0693 4.81 0.0695 4.80 0.0696 4.79 0.0697 4.77 0.0699 4.76 0.0700 4.75 0.0701 4.73 0.0702 4.72 M1418, Rev. 1 Page 1 of 24 Ending Temp "F
- c 144.87 62.71 149.73 65.41 154.57 68.10 159.40 70.78 164.21 73.45 169.01 76.12 173.79 78.77 178.57 81.43 183.33 84.07 188.07 86.71 192.81 89.34 197.53 91.96 0.3 0.025 197.53 6.44E+03 450.136 0.0615 0.325 0.025 202.24 6.44E+03 450.136 0.0617 0.35 0.025 206.93 6.44E+03 450.136 0.0619 0.375 0.025 211.62 6.44E+03 450.136 0.0620 0.4 0.025 216.30 6.44E+03 450.136 0.0622 0.425 0.025 220.96 6.44E+03 450.136 0.0623 0.45 0.025 225.61 6.44E+03 450.136 0.0625 0.475 0.025 230.26 6.44E+03 450.136 0.0626 0.5 0.025 234.89 6.44E+03 450.136 0.0628 0.525 0.025 239.51 6.44E+03 450.136 0.0629 0.55 0.025 244.13 6.44E+03 450.136 0.0630 0.575 0.025 248.73 6.44E+03 450.136 0.0632 0.6 0.025 253.32 6.44E+03 450.136 0.0633 0.625 0.025 257.91 6.44E+03 450.136 0.0634 0.65 0.025 262.48 6.44E+03 450.136 0.0636 0.675 0.025 267.05 6.44E+03 450.136 0.0637 0.7 0.025 271.61 6.44E+03 450.136 0.0638 0.725 0.025 276.16 6.44E+03 450.136 0.0639 0.75 0.025 280.70 6.44E+03 450.136 0.0640 0.775 0.025 285.24 6.44E+03 450.136 0.0642 0.8 0.025 289.77 6.44E+03 450.136 0.0643 0.825 0.025 294.29 6.44E+03 450.136 0.0644 0.85 0.025 298.80 6.44E+03 450.136 0.0645 0.875 0.025 303.30 6.44E+03 450.136 0.0646 0.9 0.025 307.80 6.44E+03 450.136 0.0647 0.925 0.025 312.29 6.44E+03 450.136 0.0648 0.95 0.025 316.78 6.44E+03 450.136 0.0649 0.975 0.025 321.26 6.44E+03 450.136 0.0650 1
0.025 325.73 6.44E+03 450.136 0.0651 1.025 0.025 330.19 6.44E+03 450.136 0.0652 1.05 0.025 334.65 6.44E+03 450.136 0.0653 1.075 0.025 339.10 6.44E+03 450.136 0.0654 1.1 0.025 343.55 6.44E+03 450.136 0.0655 1.125 0.025 347.99 6.44E+03 450.136 0.0656 1.15 0.025 352.42 6.44E+03 450.136 0.0657 1.175 0.025 356.85 6.44E+03 450.136 0.0658 91.858 0.0704 4.71 91.858 0.0705 4.70 91.858 0.0706 4.69 91.858 0.0708 4.68 91.858 0.0709 4.66 91.858 0.0710 4.65 91.858 0.0712 4.64 91.858 0.0713 4.63 91.858 0.0714 4.62 91.858 0.0716 4.61 91.858 0.0717 4.60 91.858 0.0718 4.59 91.858 0.0719 4.58 91.858 0.0721 4.58 91.858 0.0722 4.57 91.858 0.0722 4.56 91.858 0.0723 4.55 91.858 0.0724 4.54 91.858 0.0725 4.54 91.858 0.0725 4.53 91.858 0.0726 4.52 91.858 0.0727 4.51 91.858 0.0727 4.51 91.858 0.0728 4.50 91.858 0.0729 4.49 91.858 0.0730 4.48 91.858 0.0730 4.48 91.858 0.0731 4.47 91.858 0.0732 4.46 91.858 0.0733 4.46 91.858 0.0733 4.45 91.858 0.0734 4.45 91.858 0.0735 4.44 91.858 0.0735 4.43 91.858 0.0736 4.43 91.858 0.0737 4.42 M1418, Rev. 1 Page 2 of 24 202.24 94.58 206.93 97.19 211.62 99.79 216.30 102.39 220.96 104.98 225.61 107.56 230.26 110.14 234.89 112.72 239.51 115.29 244.13 117.85 248.73 120.41 253.32 122.96 257.91 125.50 262.48 128.05 267.05 130.58 271.61 133.12 276.16 135.64 280.70 138.17 285.24 140.69 289.77 143.20 294.29 145.71 298.80 148.22 303.30 150.72 307.80 153.22 312.29 155.72 316.78 158.21 321.26 160.70 325.73 163.18 330.19 165.66 334.65 168.14 339.10 170.61 343.55 173.08 347.99 175.55 352.42 178.01 356.85 180.47 361.27 182.93 1.2 0.025 361.27 6.44E+03 450.136 0.0659 1.225 0.025 365.68 6.44E+03 450.136 0.0660 1.25 0.025 370.09 6.44E+03 450.136 0.0661 1.275 0.025 374.50 6.44E+03 450.136 0.0662 1.3 0.025 378.90 6.44E+03 450.136 0.0663 1.325 0.025 383.29 6.44E+03 450.136 0.0663 1.35 0.025 387.68 6.44E+03 450.136 0.0664 1.375 0.025 392.06 6.44E+03 450.136 0.0665 1.4 0.025 396.44 6.44E+03 450.136 0.0666 1.425 0.025 400.81 6.44E+03 450.136 0.0667 1.45 0.025 405.18 6.44E+03 450.136 0.0668 1.475 0.025 409.54 6.44E+03 450.136 0.0668 1.5 0.025 413.90 6.44E+03 450.136 0.0669 1.525 0.025 418.25 6.44E+03 450.136 0.0670 1.55 0.025 422.60 6.44E+03 450.136 0.0671 1.575 0.025 426.94 6.44E+03 450.136 0.0671 1.6 0.025 431.28 6.44E+03 450.136 0.0672 1.625 0.025 435.61 6.44E+03 450.136 0.0673 1.65 0.025 439.94 6.44E+03 450.136 0.0674 1.675 0.025 444.27 6.44E+03 450.136 0.0674 1.7 0.025 448.59 6.44E+03 450.136 0.0675 1.725 0.025 452.90 6.44E+03 450.136 0.0676 1.75 0.025 457.21 6.44E+03 450.136 0.0676 1.775 0.025 461.52 6.44E+03 450.136 0.0677 1.8 0.025 465.82 6.44E+03 450.136 0.0678 1.825 0.025 470.12 6.44E+03 450.136 0.0678 1.85 0.025 474.42 6.44E+03 450.136 0.0679 1.875 0.025 478.71 6.44E+03 450.136 0.0680 1.9 0.025 482.99 6.44E+03 450.136 0.0680 1.925 0.025 487.27 6.44E+03 450.136 0.0681 1.95 0.025 491.55 6.44E+03 450.136 0.0682 1.975
-0.025 495.82 6.44E+03 450.136 0.0682 2
0.025 500.09 6.44E+03 450.136 0.0683 2.025 0.025 504.36 6.44E+03 450.136 0.0684 2.05 0.025 508.62 6.44E+03 450.136 0.0684 2.075 0.025 512.88 6.44E+03 450.136 0.0685 91.858 0.0737 4.42 91.858 0.0738 4.41 91.858 0.0739 4.40 91.858 0.0740 4.40 91.858 0.0740 4.39 91.858 0.0741 4.39 91.858 0.0742 4.38 91.858 0.0742 4.38 91.858 0.0743 4.37 91.858 0.0744 4.37 91.858 0.0745 4.36 91.858 0.0745 4.36 91.858 0.0746 4.35 91.858 0.0747 4.35 91.858 0.0747 4.34 91.858 0.0748 4.34 91.858 0.0749 4.33 91.858 0.0749 4.33 91.858 0.0750 4.32 91.858 0.0751 4.32 91.858 0.0751 4.32 91.858 0.0752 4.31 91.858 0.0753 4.31 91.858 0.0754 4.30 91.858 0.0754 4.30 91.858 0.0755 4.29 91.858 0.0756 4.29 91.858 0.0756 4.29 91.858 0.0757 4.28 91.858 0.0758 4.28 91.858 0.0758 4.27 91.858 0.0759 4.27 91.858 0.0760 4.27 91.858 0.0760 4.26 91.858 0.0761 4.26 91.858 0.0762 4.25 M1418, Rev. 1 Page 3 of 24 365.68 185.38 370.09 187.83 374.50 190.28 378.90 192.72 383.29 195.16 387.68 197.60 392.06 200.03 396.44 202.47 400.81 204.90 405.18 207.32 409.54 209.75 413.90 212.17 418.25 214.58 422.60 217.00 426.94 219.41 431.28 221.82 435.61 224.23 439.94 226.64 444.27 229.04 448.59 231.44 452.90 233.83 457.21
. 236.23 461.52 238.62 465.82 241.01 470.12 243.40 474.42 245.79 478.71 248.17 482.99 250.55 487.27 252.93 491.55 255.31 495.82 257.68 500.09 260.05 504.36 262.42 508.62 264.79 512.88 267.16 517.14 269.52 2.1 0.025 517.14 6.44E+03 450.136 0.0685 2.125 0.025 521.39 6.44E+03 450.136 0.0686 2.15 0.025 525.63 6.44E+03 450.136 0.0687 2.175 0.025 529.88 6.44E+03 450.136 0.0687 2.2 0.025 534.12 6.44E+03 450.136 0.0688 2.225 0.025 538.35 6.44E+03 450.136 0.0688 2.25 0.025 542.59 6.44E+03 450.136 0.0689 2.275 0.025 546.82 6.44E+03 450.136 0.0689 2.3 0.025 551.04 6.44E+03 450.136 0.0690 2.325 0.025 555.27 6.44E+03 450.136 0.0690 2.35 0.025 559.48 6.44E+03 450.136 0.0691 2.375 0.025 563.70 6.44E+03 450.136 0.0692 2.4 0.025 567.91 6.44E+03 450.136 0.0692 2.425 0.025 572.12 6.44E+03 450.136 0.0693 2.45 0.025 576.33 6.44E+03 450.136 0.0693 2.475 0.025 580.53 6.44E+03 450.136 0.0694 2.5 0.025 584.39 6.44E+03 450.136 0.0694 2.525 0.025 588.24 6.44E+03 450.136 0.0695 2.55 0.025 592.10 6.44E+03 450.136 0.0695 2.575 0.025 595.95 6.44E+03 450.136 0.0695 2.6 0.025 599.80 6.44E+03 450.136 0.0696 2.625 0.025 603.64 6.44E+03 450.136 0.0696 2.65 0.025 607.48 6.44E+03 450.136 0.0697 2.675 0.025 611.32 6.44E+03 450.136 0.0697 2.7 0.025 615.16 6.44E+03 450.136 0.0698 2.725 0.025 619.00 6.44E+03 450.136 0.0698 2.75 0.025 622.83 6.44E+03 450.136 0.0699 2*_775 0.025 626.66 6.44E+03 450.136 0.0699 2.8 0.025 630.48 6.44E+03 450.136 0.0699 2.825 0.025 634.31 6.44E+03 450.136 0.0700 2.85 0.025 638.13 6.44E+03 450.136 0.0700 2.875 0.025 641.95 6.44E+03 450.136 0.0701 2.9 0.025 645.77 6.44E+03 450.136 0.0701 2.925 0.025 649.58 6.44E+03 450.136 0.0701 2.95 0.025 653.40 6.44E+03 450.136 0.0702 2.975 0.025 657.21 6.44E+03 450.136 0.0702 91.858 0.0762 4.25 91.858 0.0763 4.25 91.858 0.0764 4.24 91.858 0.0765 4.24 91.858 0.0765 4.24 91.858 0.0766 4.23 91.858 0.0767 4.23 91.858 0.0767 4.23 91.858 0.0768 4.22 91.858 0.0769 4.22 91.858 0.0769 4.22 91.858 0.0770 4.21 91.858 0.0771 4.21 91.858 0.0771 4.21 91.858 0.0772 4.20 135.678 0.0773 3.86 135.678 0.0773 3.86 135.678 0.0774 3.85 135.678 0.0775 3.85 135.678 0.0775 3.85 135.678 0.0776 3.85 135.678 0.0776 3.84 135.678 0.0777 3.84 135.678 0.0778 3.84 135.678 0.0778 3.83 135.678 0.0779 3.83 135.678 0.0779 3.83 135.678 0.0780 3.83 135.678 0.0781 3.82 135.678 0.0781 3.82 135.678 0.0782 3.82 135.678 0.0783 3.82 135.678 0.0783 3.81 135.678 0.0784 3.81 135.678 0.0784 3.81 135.678 0.0785 3.81 M1418, Rev. 1 Page 4 of 24 521.39 271.88 525.63 274.24 529.88 276.60 534.12 278.95 538.35 281.31 542.59 283.66 546.82 286.01 551.04 288.36 555.27 290.70 559.48 293.05 563.70 295.39 567.91 297.73 572.12 300.07 576.33 302.40 580.53 304.74 584.39 306.88 588.24 309.02 592.10 311.17 595.95 313.30 599.80 315.44 603.64 317.58 607.48 319.71 611.32 321.85 615.16 323.98 619.00 326.11 622.83 328.24 626.66 330.37 630.48 332.49 634.31 334.62 638.13 336.74 641.95 338.86 645.77 340.98 649.58 343.10 653.40 345.22 657.21 347.34 661.01 349.45 3
0.025 661.01 6.44E+03 450.136 0.0703 3.025 0.025 664.82 6.44E+03 450.136 0.0703 3.05 0.025 668.62 6.44E+03 450.136 0.0703 3.075 0.025 672.42 6.44E+03 450.136 0.0704 3.1 0.025 676.22 6.44E+03 450.136 0.0704 3.125 0.025 680.02 6.44E+03 450.136 0.0705 3.15 0.025 683.81 6.44E+03 450.136 0.0705 3.175 0.025 687.60 6.44E+03 450.136 0.0705 3.2 0.025 691.39 6.44E+03 450.136 0.0706 3.225 0.025 695.18 6.44E+03 450.136 0.0706 3.25 0.025 698.96 6.44E+03 450.136 0.0707 3.275 0.025 702.74 6.44E+03 450.136 0.0707 3.3 0.025 706.53 6.44E+03 450.136 0.0707 3.325 0.025 710.30 6.44E+03 450.136 0.0708 3.35 0.025 714.08 6.44E+03 450.136 0.0708 3.375 0.025 717.85 6.44E+03 450.136 0.0708 3.4 0.025 721.63 6.44E+03 450.136 0.0709 3.425 0.025 725.40 6.44E+03 450.136 0.0709 3.45 0.025 729.17 6.44E+03 450.136 0.0709 3.475 0.025 732.93 6.44E+03 450.136 0.0710 3.5 0.025 736.70 6.44E+03 450.136 0.0710 3.525 0.025 740.46 6.44E+03 450.136 0.0710 3.55 0.025 744.22 6.44E+03 450.136 0.0711 3.575 0.025 747.98 6.44E+03 450.136 0.0711 3.6 0.025 751.74 6.44E+03 450.136 0.0712 3.625 0.025 755.49 6.44E+03 450.136 0.0712 3.65 0.025 759.24 6.44E+03 450.136 0.0712 3.675 0.025 762.99 6.44E+03 450.136 0.0713 3.7 0.025 766.74 6.44E+03 450.136 0.0713 3.725 0.025 770.49 6.44E+03 450.136 0.0713 3.75 0.025 774.24 6.44E+03 450.136 0.0714 3.775 0.025 777.98 6.44E+03 450.136 0.0714 3.8 0.025 781.72 6.44E+03 450.136 0.0714 3.825 0.025 785.46 6.44E+03 450.136 0.0714 3.85 0.025 789.20 6.44E+03 450.136 0.0715 3.875 0.025 792.93 6.44E+03 450.136 0.0715 135.678 0.0786 3.81 135.678 0.0786 3.80 135.678 0.0787 3.80 135.678 0.0787 3.80 135.678 0.0788 3.80 135.678 0.0789 3.79 135.678 0.0789 3.79 135.678 0.0790 3.79 135.678 0.0790 3.79 135.678 0.0791 3.78 135.678 0.0791 3.78 135.678 0.0792 3.78 135.678 0.0792 3.78 135.678 0.0793 3.78 135.678 0.0793 3.77 135.678 0.0794 3.77 135.678 0.0794 3.77 135.678 0.0795 3.77 135.678 0.0795 3.77 135.678 0.0796 3.76 135.678 0.0796 3.76 135.678 0.0797 3.76 135.678 0.0797 3.76 135.678 0.0798 3.76 135.678 0.0798 3.75 135.678 0.0799 3.75 135.678 0.0799 3.75 135.678 0.0800 3.75 135.678 0.0800 3.75 135.678 0.0801 3.75 135.678 0.0801 3.74 135.678 0.0802 3.74 135.678 0.0802 3.74 135.678 0.0803 3.74 135.678 0.0803 3.74 135.678 0.0804 3.73 M1418, Rev. 1 Page 5 of 24 664.82 351.57 668.62 353.68 672.42 355.79 676.22 357.90 680.02 360.01 683.81 362.12 687.60 364.22 691.39 366.33 695.18 368.43 698.96 370.53 702.74 372.64 706.53 374.74 710.30 376.84 714.08 378.93 717.85 381.03 721.63 383.13 725.40 385.22 729.17 387.31 732.93 389.41 736.70 391.50 740.46 393.59 744..22 395.68 747.98 397.77 751.74 399.85 755.49 401.94 759.24 404.02 762.99 406.11 766.74 408.19 770.49 410.27 774.24 412.35 777.98 414.43 781.72 416.51 785.46 418.59 789.20 420.67 792.93 422.74 796.67 424.82
3.9 0.025 796.67 6.44E+03 3.925 0.025 800.40 6.44E+03 3.95 0.025 804.13 6.44E+03.
3.975 0.025 807.86 6.44E+03 4
0.025 811.59 6.44E+03 4.025 0.025 815.31 6.44E+03 4.05 0.025 819.04 6.44E+03 4.075 0.025 822.76 6.44E+03 4.1 0.025 826.48 6.44E+03 4.125 0.025 830.20 6.44E+03 4.15 0.025 833.91 6.44E+03 4.175 0.025 837.63 6.44E+03 4.2 0.025 841.34 6.44E+03 4.225 0.025 845.05 6.44E+03 4.25 0.025 848.76 6.44E+03 4.275 0.025 852.47 6.44E+03 4.3 0.025 856.18 6.44E+03 4.325 0.025 859.88 6.44E+03 4.35 0.025 863.59 6.44E+03 4.375 0.025 867.29 6.44E+03 4.4 0.025 870.99 6.44E+03 4.425 0.025 874.69 6.44E+03 4.45 0.025 878.38 6.44E+03 4.475 0.025 882.08 6.44E+03 4.5 0.025 885.77 6.44E+03 4.525 0.025 889.46 6.44E+03 4.55 0.025 893.15 6.44E+03 4.575 0.025 896.84 6.44E+03 4.6 0.025 900.53 6.44E+03 4.625 0.025 904.21 6.44E+03 4.65 0.025 907.90 6.44E+03 4.675 0.025 911.58 6.44E+03 4.7 0.025 915.26 6.44E+03 4.725 0.025 918.94 6.44E+03 4.75 0.025 922.62 6.44E+03 4.775 0.025 926.29 6.44E+03 450.136 0.0715 135.678 0.0804 450.136 0.0716 135.678 0.0805 450.136 0.0716 135.678 0.0805 450.136 0.0716 135.678 0.0806 450.136 0.0717 135.678 0.0806 450.136 0.0717 135.678 0.0807 450.136 0.0717 135.678 0.0807 450.136 0.0718 135.678 0.0808 450.136 0.0718 135.678 0.0808 450.136 0.0718 135.678 0.0808 450.136 0.0718 135.678 0.0809 450.136 0.0719 135.678 0.0809 450.136 0.0719 135.678
- 0.0810 450.136 0.0719 135.678 0.0810 450.136 0.0720 135.678 0.0811 450.136 0.0720 135.678 0.0811 450.136 0.0720 135.678 0.0812 450.136 0.0721 135.678 0.0812 450.136 0.0721 135.678 0.0813 450.136 0.0721 135.678 0.0813 450.136 0.0721 135.678 0.0814 450.136 0.0722 135.678 0.0814 450.136 0.0722 135.678 0.0815 450.136 0.0722 135.678 0.0815 450.136 0.0723 135.678 0.0816 450.136 0.0723 135.678 0.0816 450.136 0.0723 135.678 0.0817 450.136 0.0723 135.678 0.0817 450.136 0.0724 135.678 0.0818 450.136 0.0724 135.678 0.0818 450.136 0.0724 135.678 0.0819 450.136 0.0724 135.678 0.0819 450.136 0.0725 135.678 0.0820 450.136 0.0725 135.678 0.0820 450.136 0.0725 135.678 0.0820 450.136 0.0725 135.678 0.0821 3.73 3.73 3.73 3.73 3.73 3.72 3.72 3.72 3.72 3.72 3.71 3.71 3.71 3.71 3.71 3.71 3.70 3.70 3.70 3.70 3.70 3.70 3.69 3.69 3.69 3.69 3.69 3.69 3.69 3.68 3.68 3.68 3.68 3.68 3.68 3.67 M1418, Rev. 1 Page 6 of 24 800.40 426.89 804.13 428.96 807.86 431.03 811.59 433.10 815.31 435.17 819.04 437.24 822.76 439.31 826.48 441.38 830.20 443.44 833.91 445.51 837.63 447.57 841.34 449.63 845.05 451.70 848.76 453.76 852.47 455.82 856.18 457.88 859.88 459.93 863.59 461.99 867.29 464.05 870.99 466.10 874.69 468.16 878.38 470.21 882.08 472.27 885.77 474.32 889.46 476.37 893.15 478.42 896.84 480.47 900.53 482.52 904.21 484.56 907.90 486.61 911.58 488.66 915.26 490.70 918.94 492.74 922.62 494.79 926.29 496.83 929.97 498.87 4.8 0.025 929.97 6.44E+03 450.136 0.0726 4.825 0.025 933.64 6.44E+03 450.136 0.0726 4.85 0.025 937.31 6.44E+03 450.136 0.0726 4.875 0.025 940.98 6.44E+03 450.136 0.0727 4.9 0.025 944.65 6.44E+03 450.136 0.0727 4.925 0.025 948.32 6.44E+03 450.136 0.0727 4.95 0.025 951.98 6.44E+03 450.136 0.0727 4.975 0.025 955.65 6.44E+03 450.136 0.0728 5
0.025 959.31 6.44E+03 450.136 0.0728 5.025 0.025 962.97 6.44E+03 450.136 0.0728 5.05 0.025 966.63 6.44E+03 450.136 0.0728 5.075 0.025 970.29 6.44E+03 450.136 0.0729 5.1 0.025 973.94 6.44E+03 450.136 0.0729 5.125 0.025 977.60 6.44E+03 450.136 0.0729 5.15 0.025 981.25 6.44E+03 450.136 0.0729 5.175 0.025 984.90 6.44E+03 450.136 0.0730 5.2 0.025 988.55 6.44E+03 450.136 0.0730 5.225 0.025 992.20 6.44E+03 450.136 0.0730 5.25 0.025 995.85 6.44E+03 450.136 0.0730 5.275 0.025 999.50 6.44E+03 450.136 0.0731 5.3 0.025 1003.14 6.44E+03 450.136 0.0731 5.325 0.025 1006.79 6.44E+03 450.136 0.0731 5.35 0.025 1010.43 6.44E+03 450.136 0.0731 5.375 0.025 1014.07 6.44E+03 450.136 0.0731 5.4 0.025 1017.71 6.44E+03 450.136 0.0732 5.425 0.025 1021.35 6.44E+03 450.136 0.0732 5.45 0.025 1024.98 6.44E+03 450.136 0.0732 5.475 0.025 1028.62 6.44E+03 450.136 0.0732 5.5 0.025 1032.25 6.44E+03 450.136 0.0733 5.525 0.025 1035.88 6.44E+03 450.136 0.0733 5.55 0.025 1039.52 6.44E+03 450.136 0.0733 5.575 0.025 1043.14 6.44E+03 450.136 0.0733 5.6 0.025 1046.77 6.44E+03 450.136 0.0734 5.625 0.025 1050.40 6.44E+03 450.136 0.0734 5.65 0.025 1054.03 6.44E+03 450.136 0.0734 5.675 0.025 1057.65 6.44E+03 450.136 0.0734 135.678 0.0821 3.67 135.678 0.0822 3.67 135.678 0.0822 3.67 135.678 0.0823 3.67 135.678 0.0823 3.67 135.678 0.0824 3.67 135.678 0.0824 3.66 135.678 0.0825 3.66 135.678 0.0825 3.66 135.678 0.0826 3.66 135.678 0.0826 3.66 135.678 0.0827 3.66 135.678 0.0827 3.66 135.678 0.0828 3.65 135.678 0.0828 3.65 135.678 0.0829 3.65 135.678 0.0829 3.65 135.678 0.0829 3.65 135.678 0.0830 3.65 135.678 0.0830 3.64 135.678 0.0831 3.64 135.678 0.0831 3.64 135.678 0.0832 3.64 135.678 0.0832 3.64 135.678 0.0833 3.64 135.678 0.0833 3.64 135.678 0.0834 3.64 135.678 0.0834 3.63 135.678 0.0835 3.63 135.678 0.0835 3.63 135.678 0.0836
- 3.63 135.678 0.0836 3.63 135.678 0.0837 3.63 135.678 0.0837 3.63 135.678 0.0838 3.62 135.678 0.0838 3.62 M1418, Rev. 1 Page 7 of 24 933.64 500.91 937.31 502.95 940.98 504.99 944.65 507.03 948.32 509.07 951.98 511.10 955.65 513.14 959.31 515.17 962.97 517.21 966.63 519.24 970.29 521.27 973.94 523.30 977.60 525.33 981.25 527.36 984.90 529.39 988.55 531.42 992.20 533.45 995.85 535.47 999.50 537.50 1003.14 539.52 1006.79 541.55 1010.43 543.57 1014.07 545.59 1017.71 547.62 1021.35 549.64 1024.98 551.66 1028.62 553.68 1032.25 555.70 1035.88 557.71 1039.52 559.73 1043.14 561.75 1046.77 563.76 1050.40 565.78 1054.03 567.79 1057.65 569.81 1061.27 571.82 5.7 0.025 1061.27 6.44E+03 450.136 0.0734 5.725 0.025 1064.89 6.44E+03 450.136 0.0735 5.75 0.025 1068.51 6.44E+03 450.136 0.0735 5.775 0.025 1072.13 6.44E+03 450.136 0.0735 5.8 0.025 1075.75 6.44E+03 450.136 0.0735 5.825 0.025 1079.37 6.44E+03 450.136 0.0736 5.85 0.025 1082.98 6.44E+03 450.136 0.0736 5.875 0.025 1086.59 6.44E+03 450.136 0.0736 5.9 0.025 1090.21 6.44E+03 450.136 0.0736 5.925 0.025 1093.82 6.44E+03 450.136 0.0736 5.95 0.025 1097.43 6.44E+03 450.136 0.0737 5.975 0.025 1101.03 6.44E+03 450.136 0.0737 6
0.025 1104.64 6.44E+03 450.136 0.0737 6.025 0.025 1108.25 6.44E+03 450.136 0.0737 6.05 0.025 1111.85 6.44E+03 450.136 0.0738 6.075 0.025 1115.45 6.44E+03 450.136 0.0738 6.1 0.025 1119.06 6.44E+03 450.136 0.0738 6.125 0.025 1122.66 6.44E+03 450.136 0.0738 6.15 0.025 1126.25 6.44E+03 450.136 0.0738 6.175 0.025 1129.85 6.44E+03 450.136 0.0739 6.2 0.025 1133.45 6.44E+03 450.136 0.0739 6.225 0.025 1137.04 6.44E+03 450.136 0.0739 6.25 0.025 1140.64 6.44E+03 450.136 0.0739 6.275 0.025 1144.23 6.44E+03 450.136 0.0739 6.3 0.025 1147.82 6.44E+03 450.136 0.0740 6.325 0.025 1151.41 6.44E+03 450.136 0.0740 6.35 0.025 1155.00 6.44E+03 450.136 0.0740 6.375 0.025 1158.59 6.44E+03 450.136 0.0740 6.4 0.025 1162.18 6.44E+03 450.136 0.0740 6.425 0.025 1165.76 6.44E+03 450.136 0.0741 6.45 0.025 1169.35 6.44E+03 450.136 0.0741 6.475 0.025 1172.93 6.44E+03 450.136 0.0741 6.5 0.025 1176.51 6.44E+03 450.136 0.0741 6.525 0.025 1180.09 6.44E+03 450.136 0.0741 6.55 0.025 1183.67 6.44E+03 450.136 0.0742 6.575 0.025 1187.25 6.44E+03 450.136 0.0742 135.678 0.0838 3.62 135.678 0.0839 3.62 135.678 0.0839 3.62 135.678 0.0840 3.62 135.678 0.0840 3.62 135.678 0.0841 3.61 135.678 0.0841 3.61 135.678 0.0842 3.61 135.678 0.0842 3.61 135.678 0.0843 3.61 135.678 0.0843 3.61 135.678 0.0844 3.61 135.678 0.0844 3.61 135.678 0.0845 3.60 135.678 0.0845 3.60 135.678 0.0845 3.60 135.678 0.0846 3.60 135.678 0.0846 3.60 135.678 0.0847 3.60 135.678 0.0847 3.60 135.678 0.0848 3.60 135.678 0.0848 3.59 135.678 0.0849 3.59 135.678 0.0849 3.59 135.678 0.0850 3.59 135.678 0.0850 3.59 135.678 0.0851 3.59 135.678 0.0851 3.59 135.678 0.0852 3.59 135.678 0.0852 3.58 135.678 0.0852 3.58 135.678 0.0853 3.58 135.678 0.0853 3.58 135.678 0.0854 3.58 135.678 0.0854 3.58 135.678 0.0855 3.58 M1418, Rev. 1 Page 8 of 24 1064.89 573.83 1068.51 575.84 1072.13 577.85 1075.75 579.86 1079.37 581.87 1082.98 583.88 1086.59 585.89 1090.21 587.89 1093.82 589.90 1097.43 591.90 1101.03 593.91 1104.64 595.91 1108.25 597.91 1111.85 599.92 1115.45 601.92 1119.06 603.92 1122.66 605.92 1126.25 607.92 1129.85 609.92 1133.45 611.92 1137.04 613.91 1140.64 615.91 1144.23 617.91 1147.82 619.90 1151.41 621.90 1155.00 623.89 1158.59 625.88 1162.18 627.88 1165.76 629.87 1169.35 631.86 1172.93 633.85 1176.51 635.84 1180.09 637.83 1183.67 639.82 1187.25 641.80 1190.82 643.79
6.6 0.025 1190.82 6.44E+03 6.625 0.025 1194.40 6.44E+03 6.65 0.025 1197.97 6.44E+03 6.675 0.025 1201.55 6.44E+03 6.7 0.025 1205.12 6.44E+03 6.725 0.025 1208.69 6.44E+03 6.75 0.025 1212.26 6.44E+03 6.775 0.025 1215.83 6.44E+03 6.8 0.025 1219.39 6.44E+03 6.825 0.025 1222.96 6.44E+03 6.85 0.025 1226.52 6.44E+03 6.875 0.025 1230.09 6.44E+03 6.9 0.025 1233.65 6.44E+03 6.925 0.025 1237.21 6.44E+03 6.95 0.025 1240.77 6.44E+03 6.975 0.025 1244.33 6.44E+03 7
0.025 1247.89 6.44E+03 7.025 0.025 1251.44 6.44E+03 7.05 0.025 1255.00 6.44E+03 7.075 0.025 1258.55 6.44E+03 7.1 0.025 1262.11 6.44E+03 7.125 0.025 1265.66 6.44E+03 7.15 0.025 1269.21 6.44E+03 7.175 0.025 1272.76 6.44E+03 7.2 0.025 1276.31 6.44E+03 7.225 0.025 1279.85 6.44E+03 7.25 0.025 1283.40 6.44E+03 7.275 0.025 1286.94 6.44E+03 7.3 0.025 1290.49 6.44E+03 7.325 0.025 1294.03 6.44E+03 7.35 0.025 1297.57 6.44E+03 7.375 0.025 1301.11 6.44E+03 7.4 0.025 1304.65 6.44E+03 7.425 0.025 1308.19 6.44E+03 7.45 0.025 1311.73 6.44E+03 7.475 0.025 1315.26 6.44E+03 450.136 0.0742 135.678 0.0855 450.136 0.0742 135.678 0.0856 450.136 0.0742 135.678 0.0856 450.136 0.0743 135.678 0.0857 450.136 0.0743 135.678 0.0857 450.136 0.0743 135.678 0.0858 450.136 0.0743 135.678 0.0858 450.136 0.0743 135.678 0.0859 450.136 0.0744 135.678 0.0859 450.136 0.0744 135.678 0.0859 450.136 0.0744 135.678 0.0860 450.136 0.0744 135.678 0.0860 450.136 0.0744 135.678 0.0861 450.136 0.0745 135.678 0.0861 450.136 0.0745 135.678 0.0862 450.136 0.0745 135.678 0.0862 450.136 0.0745 135.678 0.0863 450.136 0.0745 135.678 0.0863 450.136 0.0746 135.678 0.0864 450.136 0.0746 135.678 0.0864 450.136 0.0746 135.678 0.0865 450.136 0.0746 135.678 0.0865 450.136 0.0746 135.678 0.0865 450.136 0.0747 135.678 0.0866 450.136 0.0747 135.678 0.0866 450.136 0.0747 135.678 0.0867 450.136 0.0747 135.678 0.0867 450.136 0.0747 135.678 0.0868 450.136 0.0747 135.678 0.0868 450.136 0.0748 135.678 0.0869 450.136 0.0748 135.678 0.0869 450.136 0.0748 135.678 0.0870 450.136 0.0748 135.678 0.0870 450.136 0.0748 135.678 0.0870 450.136 0.0749 135.678 0.0871.
450.136 0.0749 135.678 0.0871 3.58 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.56 3.56 3.56 3.56 3.56 3.56 3.56 3.56 3.56 3.55 3.55 3.55 3.55 3.55 3.55 3.55 3.55 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.54 3.53 M1418, Rev. 1 Page 9 of 24 1194.40 645.78 1197.97 647.76 1201.55 649.75 1205.12 651.73 1208.69 653.72 1212.26 655.70 1215.83 657.68 1219.39 659.66 1222.96 661.64 1226.52 663.62 1230.09 665.60 1233.65 667.58 1237.21 669.56 1240.77 671.54 1244.33 673.52 1247.89 675.49 1251.44 677.47 1255.00 679.44 1258.55 681.42 1262.11 683.39 1265.66 685.36 1269.21 687.34 1272.76 689.31 1276.31 691.28 1279.85 693.25 1283.40 695.22 1286.94 697.19 1290.49 699.16 1294.03 701.13 1297.57 703.09 1301.11 705.06 1304.65 707.03 1308.19 708.99 1311.73 710.96 1315.26 712.92 1318.80 714.89 7.5 0.025 1318.80 6.44E+03 450.136 0.0749 7.525 0.025 1322.33 6.44E+03 450.136 0.0749 7.55 0.025 1325.86 6.44E+03 450.136 0.0749 7.575 0.025 1329.39 6.44E+03 450.136 0.0749 7.6 0.025 1332.92 6.44E+03 450.136 0.0750 7.625 0.025 1336.45 6.44E+03 450.136 0.0750 7.65 0.025 1339.98 6.44E+03 450.136 0.0750 7.675 0.025 1343.51 6.44E+03 450.136 0.0750 7.7 0.025 1347.03 6.44E+03 450.136 0.0750 7.725 0.025 1350.56 6.44E+03 450.136 0.0751 7.75 0.025 1354.08 6.44E+03 450.136 0.0751 7.775 0.025 1357.60 6.44E+03 450.136 0.0751 7.8 0.025 1361.12 6.44E+03 450.136 0.0751 7.825 0.025 1364.65 6.44E+03 450.136 0.0751 7.85 0.025 1368.16 6.44E+03 450.136 0.0751 7.875 0.025 1371.68 6.44E+03 450.136 0.0752 7.9 0.025 1375.20 6.44E+03 450.136 0.0752 7.925 0.025 1378.72 6.44E+03 450.136 0.0752 7.95 0.025 1382.23 6.44E+03 450.136 0.0752 7.975 0.025 1385.74 6.44E+03 450.136 0.0752 8
0.025 1389.26 6.44E+03 450.136 0.0752 8.025 0.025 1392.77 6.44E+03 450.136 0.0753 8.05 0.025 1396.28 6.44E+03 450.136 0.0753 8.075 0.025 1399.79 6.44E+03 450.136 0.0753 8.1 0.025 1403.30 6.44E+03 450.136 0.0753 8.125 0.025 1406.80 6.44E+03 450.136 0.0753 8.15 0.025 1410.31 6.44E+03 450.136 0.0754 8.175 0.025 1413.82 6.44E+03 450.136 0.0754 8.2 0.025 1417.32 6.44E+03 450.136 0.0754 8.225 0.025 1420.82 6.44E+03 450.136 0.0754 8.25 0.025 1424.33 6.44E+03 450.136 0.0754 8.275 0.025 1427.83 6.44E+03 450.136 0.0754 8.3 0.025 1431.33 6.44E+03 450.136 0.0755 8.325 0.025 1434.83 6.44E+03 450.136 0.0755 8.35 0.025 1438.32 6.44E+03 450.136 0.0755 8.375 0.025 1441.82 6.44E+03 450.136 0.0755 135.678 0.0872 3.53 135.678 0.0872 3.53 135.678 0.0873 3.53 135.678 0.0873 3.53 135.678 0.0874 3.53 135.678 0.0874 3.53 135.678 0.0875 3.53 135.678 0.0875 3.53 135.678 0.0876 3.52 135.678 0.0876 3.52 135.678 0.0876 3.52 135.678 0.0877 3.52 135.678 0.0877 3.52 135.678 0.0878 3.52 135.678 0.0878 3.52 135.678 0.0879 3.52 135.678 0.0879 3.52 135.678 0.0880 3.51 135.678 0.0880 3.51 135.678 0.0881 3.51 135.678 0.0881 3.51 135.678 0.0881 3.51 135.678 0.0882 3.51 135.678 0.0882 3.51 135.678 0.0883 3.51 135.678 0.0883 3.51 135.678 0.0884 3.51 135.678 0.0884 3.50 135.678 0.0885 3.50 135.678 0.0885 3.50 135.678 0.0886 3.50 135.678 0.0886 3.50 135.678 0.0886 3.50 135.678 0.0887 3.50 135.678 0.0887 3.50 135.678 0.0888 3.50 M1418, Rev. 1 Page 10 of 24 1322.33 716.85 1325.86 718.81 1329.39 720.77 1332.92 722.74 1336.45 724.70 1339.98 726.66 1343.51 728.61 1347.03 730.57 1350.56 732.53 1354.08 734.49 1357.60 736.45 1361.12 738.40 1364.65 740.36 1368.16 742.31 1371.68 744.27 1375.20 746.22 1378.72 748.18 1382.23 750.13 1385.74 752.08 1389.26 754.03 1392.77 755.98 1396.28 757.93 1399.79 759.88 1403.30 761.83 1406.80 763.78 1410.31 765.73 1413.82 767.68 1417.32 769.62 1420.82 771.57 1424.33 773.51 1427.83 775.46 1431.33 777.40 1434.83 779.35 1438.32 781.29 1441.82 783.23 1445.32 785.18
8.4 0.025 1445.32 6.44E+03 8.425 0.025 1448.81 6.44E+03 8.45 0.025 1452.30 6.44E+03 8.475 0.025 1455.80 6.44E+03 8.5 0.025 1459.29 6.44E+03 8.525 0.025 1462.78 6.44E+03
- 8.55 0.025 1466.27 6.44E+03 8.575 0.025 1469.76 6.44E+03 8.6 0.025 1473.25 6.44E+03 8.625 0.025 1476.73 6.44E+03 8.65 0.025 1480.22 6.44E+03 8.675 0.025 1483.70 6.44E+03 8.7 0.025 1487.18 6.44E+03 8.725 0.025 1490.67 6.44E+03 8.75 0.025 1494.15 6.44E+03 8.775 0.025 1497.63 6.44E+03 8.8 0.025 1501.11 6.44E+03 8.825 0.025 1504.59 6.44E+03 8.85 0.025 1507.94 6.44E+03 8.875 0.025 1511.13 6.44E+03 8.9 0.025 1514.31 6.44E+03 8.925 0.025 1517.47 6.44E+03 8.95 0.025 1520.61 6.44E+03 8.975 0.025 1523.74 6.44E+03 9
0.025 1526.85 6.44E+03 9.025 0.025 1529.95 6.44E+03 9.05 0.025 1533.03 6.44E+03 9.075 0.025 1536.10 6.44E+03 9.1 0.025 1539.15 6.44E+03 9.125 0.025 1542.19 6.44E+03 9.15 0.025 1545.22 6.44E+03
~.175 0.025 1548.23 6.44E+03 9.2 0.025 1551.24 6.44E+03 9.225 0.025 1554.25 6.44E+03 9.25 0.025 1557.25 6.44E+03 9.275 0.025 1560.25 6.44E+03 450.136 0.0755 135.678 0.0888 450.136 0.0755 135.678 0.0889 450.136 0.0756 135.678 0.0889 450.136 0.0756 135.678 0.0890 450.136 0.0756 135.678 0.0890 450.136 0.0756 135.678 0.0891 450.136 0.0756 135.678 0.0891 450.136 0.0756 135.678 0.0891 450.136 0.0757 135.678 0.0892 450.136 0.0757 135.678 0.0892 450.136 0.0757 135.678 0.0893 450.136 0.0757 135.678 0.0893 450.136 0.0757 135.678 0.0894 450.136 0.0757 135.678 0.0894 450.136 0.0758 135.678 0.0895 450.136 0.0758 135.678 0.0895 450.136 0.0758 135.678 0.0896 450.136 0.0758 135.678 0.1022 450.136 0.0758 135.678 0.1200 450.136 0.0758 135.678 0.1219 450.136 0.0759 135.678 0.1237 450.136 0.0759 135.678 0.1256 450.136 0.0759 135.678 0.1274 450.136 0.0759 135.678 0.1292 450.136 0.0759 135.678 0.1311 450.136 0.0759 135.678 0.1329 450.136 0.0759 135.678 0.1347 450.136 0.0760 135.678 0.1365 450.136 0.0760 135.678 0.1382 450.136 0.0760 135.678 0.1400 450.136 0.0760 135.678 0.1412 450.136 0.0760 135.678 0.1417 450.136 0.0760 135.678 0.1422 450.136 0.0760 135.678 0.1427 450.136 0.0761 135.678 0.1432 450.136 0.0761 135.678 0.1437 3.49 3.49 3.49 3.49 3.49 3.49 3.49 3.49 3.49 3.49 3.48 3.48 3.48 3.48 3.48 3.48 3.48 3.35 3.19 3.18 3.16 3.14 3.13 3.11 3.10 3.08 3.07 3.05 3.04 3.02 3.02 3.01 3.01 3.00 3.00 2.99 M1418, Rev. 1 Page 11 of 24 1448.81 787.12 1452.30 789.06 1455.80 791.00 1459.29 792.94 1462.78 794.88 1466.27 796.82 1469.76 798.75 1473.25 800.69 1476.73 802.63 1480.22 804.57 1483.70 806.50 1487.18 808.44 1490.67 810.37 1494.15 812.30 1497.63 814.24 1501.11 816.17 1504.59 818.10 1507.94 819.97 1511.13 821.74 1514.31 823.50 1517.47 825.26 1520.61 827.01 1523.74 828.74 1526.85 830.47 1529.95 832.19 1533.03 833.91 1536.10 835.61 1539.15 837.31 1542.19 839.00 1545.22 840.68 1548.23 842.35 1551.24 844.02 1554.25 845.70 1557.25 847.36 1560.25 849.03 1563.25 850.69
9.3
- 0.025 1563.25 6.44E+03 9.325 0.025 1566.24 6.44E+03 9.35 0.025 1569.23 6.44E+03 9.375 0.025 1572.21 6.44E+03 9.4 0.025 1575.19 6.44E+03 9.425 0.025 1578.16 6.44E+03 9.45 0.025 1581.13 6.44E+03 9.475 0.025 1584.09 6.44E+03 9,5c:
0.025 1587.04 6.44E+03 9.525 0.025 1589.97 6.44E+03 9.55 0.025 1592.89 6.44E+03 9.575 0.025 1595.79 6.44E+03 9.6 0.025 1598.67 6.44E+03 9.625 0.025 1601.55 6.44E+03 9.65 0.025 1604.41 6.44E+03 9.675 0.025 1607.25 6.44E+03 9.7 0.025 1610.08 6.44E+03 9.725 0.025 1612.90 6.44E+03 9.75 0.025 1615.70 6.44E+03 9.775 0.025 1618.49 6.44E+03 9.8 0.025 1621.27 6.44E+03 9.825 0.025 1624.04 6.44E+03 9.85 0.025 1626.80 6.44E+03 9.875 0.025 1629.54 6.44E+03 9.9 0.025 1632.27 6.44E+03 9.925 0.025 1635.00 6.44E+03 9.95 0.025 1637.71 6.44E+03 9.975 0.025 1640.40 6.44E+03 10 0.025 1643.09 6.44E+03 10.025 0.025 1645.77 6.44E+03 10.05 0.025 1648.44 6.44E+03 10.075 0.025 1651.09 6.44E+03 10.1 0.025 1653.74 6.44E+03 450.136 0.0761 135.678 0.1442 450.136 0.0761 135.678 0.1447 450.136 0.0761 135.678 0.1451 450.136 0.0761 135.678 0.1456 450.136 0.0761 135.678 0.1461 450.136 0.0761 135.678 0.1466 450.136 0.0762 135.678 0.1479 450.136 0.0762 135.678 0.1499 450.136 0.0762 135.678 0.1519 450.136 0.0762 135.678 0.1540 450.136 0.0762 135.678 0.1560 450.136 0.0762 135.678 0.1580 450.136 0.0762 135.678 0.1600 450.136 0.0763 135.678 0.1619 450.136 0.0763 135.678 0.1639 450.136 0.0763 135.678 0.1659 450.136 0.0763 135.678 0.1678 450.136 0.0763 135.678 0.1698 450.136 0.0763 135.678 0.1717 450.136 0.0763 135.678 0.1735 450.136 0.0763 135.678 0.1753 450.136 0.0764 135.678 0.1771 450.136 0.0764 135.678 0.1789 450.136 0.0764 135.678 0.1806 450.136 0.0764 135.678 0.1824 450.136 0.0764 135.678 0.1841 450.136 0.0764 135.678 0.1859 450.136 0.0764 135.678 0.1876 450.136 0.0764 135.678 0.1893 450.136 0.0765 135.678 0.1911 450.136 0.0765 135.678 0.1928 450.136 0.0765 135.678 0.1945 450.136 0.0765 135.678 0.1943 2.99 2.99 2.98 2.98 2.97 2.97 2.96 2.95 2.93 2.92 2.90 2.89 2.87 2.86 2.84 2.83 2.82 2.80 2.79 2.78 2.77 2.76 2.74 2.73 2.72 2.71 2.70 2.69 2.68 2.67 2.66 2.65 2.65 M1418, Rev. 1 Page 12 of 24 1566.24 852.36 1569.23 854.01 1572.21 855.67 1575.19 857.33 1578.16 858.98 1581.13 860.63 1584.09 862.27 1587.04 863.91 1589.97 865.54 1592.89 867.16 1595.79 868.77 1598.67 870.37 1601.55 871.97 1604.41 873.56 1607.25 875.14 1610.08 876.71 1612.90 878.28 1615.70 879.84 1618.49 881.39 1621.27 882.93 1624.04 884.47 1626.80 886.00 1629.54 887.52 1632.27 889.04 1635.00 890.55 1637.71 892.06 1640.40 893.56 1643.09 895.05 1645.77 896.54 1648.44 898.02 1651.09 899.50 1653.74 900.97 1656.39 902.44
U02 Specific Heat Constants (Design Input 3.2) y 2
R 8.3143 j/mol-K 8
535.285 K K1 296.7 J/kg-K K2 2.430E-02 J/kg*K2 K3 8.745E+07 J/kg Ed 1.577E+05 J/mol*-K Elapsed Cp Initial Temp Part 1 Time hr aF K
0 140.00 333.15 2.403E+02 0.025 144.87 335.86 2.411E+02 0.05 149.73 338.56 2.419E+02 0.075 154.57 341.25 2.427E+02 0.1 159.40 343.93 2.434E+02 0.125 164.21 346.60 2.441E+02 0.15 169.01 349.27 2.449E+02 0.175 173.79 351.92 2.456E+02 0.2 178.57 354.58 2.462E+02 0.225 183.33 357.22 2.469E+02 0.25 188.07 359.86 2.476E+02 0.275 192.81 362.49 2.482E+02 Zircaloy Specific Heat Cap~city Interpolation (Design Input 3.1)
Temperature Specific Heat Capicity K
aF J/kg-K BTU/lbm-°F 300 80.33 281 0.0671 400 260.33 302 0.0721 640 692.33 331 0.0791 1090 1502.33 375 0.0896 1093 1507.73 502 0.1199 1113 1543.73 590 0.1409 1133 1579.73 615 0.1469 1153 1615.73 719 0.1717 1173 1651.73 816 0.1949 1193 1687.73 770 0.1839 1213 1723.73 619 0.1478 1233 1759.73 469 0.1120
- 1248 1786.73 356 0.0850 U02 Cp Calculation Part 2 Part 3 Cp j/kg-K BTU/lbm-°F 8.096E+OO 2.81 OE-18 248.43 0.0593 8.161E+OO 4.375E-18 249.29 0.0595 8.227E+OO 6.752E-18 250.14 0.0597 8.292E+OO 1.034E-17 250.97 0.0599 8.357E+OO 1.570E-17 251.78 0.0601 8.422E+OO 2.365E-17 252.57 0.0603 8.487E+OO 3.537E-17 253.35 0.0605 8.552E+OO 5.250E-17 254.11 0.0607 8.616E+OO 7.738E-17 254.85 0.0609 8.680E+OO 1.133E-16 255.58 0.0610 8.745E+OO 1.647E-16 256.30 0.0612 8.808E+OO 2.379E-16 257.00 0.0614 M1418, Rev. 1 Page 13 of 24 Zirc Cp Interpolation Cp Table Match BTU/lbm-°F 1
0.0688 1
0.0689 1
0.0690 1
0.0692 1
0.0693 1
0.0695 1
0.0696 1
0.0697 1
0.0699 1
0.0700 1
0.0701 1
0.0702
0.3 197.53 365.11 2.488E+02 0.325 202.24 367.73 2.494E+02 0.35 206.93 370.34 2.500E+02 0.375 211.62 372.94 2.506E+02 0.4 216.30 375.54 2.512E+02 0.425 220.96 378.13 2.517E+02 0.45 225.61 380.71 2.523E+02 0.475 230.26 383.29 2.528E+02 0.5 234.89 385.87 2.534E+02 0.525 239.51 388.44 2.539E:+02 0.55 244.13 391.00 2.544E+02 0.575 248.73 393.56 2.549E+02 0.6 253.32 396.11 2.554E+02 0.625 257.91 398.65 2.559E+02 0.65 262.48 401.20 2.563E+02 0.675 267.05 403.73 2.568E+02 0.7 271.61 406.27 2.573E+02 0.725 276.16 408.79 2.577E+02 0.75 280.70 411.32 2.581E+02 0.775 285.24 413.84 2.586E+02 0.8 289.77 416.35 2.590E+02 0.825 294.29 418.86 2.594E+02 0.85 298.80 421.37 2.598E+02 0.875 303.30 423.87 2.602E+02 0.9 307.80 426.37 2.606E+02 0.925 312.29 428.87 2.610E+02 0.95 316.78 431.36 2.614E+02 0.975 321.26 433.85 2.618E+02 1
325.73 436.33 2.621E+02 1.025 330.19 438.81 2.625E+02 1.05 334.65 441.29 2.628E+02 1.075 339.10 443.76 2.632E+02 1.1 343.55 446.23 2.635E+02 1.125 347.99 448.70 2.639E+02 1.15 352.42 451.16 2.642E+02 1.175 356.85 453.62 2.645E+02 8.872E+OO 3.415E-16 257.69 8.936E+OO 4.873E-16 258.36 8.999E+OO 6.91 OE-16 259.02 9.062E+OO 9.743E-16 259.67 9.126E+OO 1.366E-15 260.31 9.189E+OO 1.905E-15 260.94 9.251E+OO 2.641 E-15 261.55 9.314E+OO 3.644E-15 262.15 9.377E+OO 5.002E-15 262.75 9.439E+OO 6.831E-15 263.33 9.501E+OO 9.285E-15 263.90 9.563E+OO 1.256E-14 264.46 9.625E+OO 1.692E-14 265.02 9.687E+OO 2.268E-14 265.56 9.749E+OO 3.027E-14 266.09 9.811E+OO 4.023E-14 266.62 9.872E+OO 5.325E-14 267.13 9.934E+OO 7.019E-14 267.64 9.995E+OO 9.217E-14 268.14 1.006E+01 1.206E-13 268.63 1.012E+01 1.571 E-13 269.12 1.018E+01 2.040E-13 269.59 1.024E+01 2.639E-13 270.06 1.030E+01 3.402E-13 270.53 1.036E+01 4.370E-13 270.98 1.042E+01 5.595E-13 271.43 1.048E+01 7.140E-13 271.87 1.054E+01 9.083E-13 272.30 1.060E+01 1.152E-12 272.73 1.066E+01 1.456E-12 273.16 1.072E+01 1.835E-12 273.57 1.078E+01 2.306E-12 273.98 1.084E+01 2.889E-12 274.39 1.090E+01 3.609E-12 274.78 1.096E+01 4.496E-12 275.18 1.102E+01 5.587E-12 275.57 0.0615 1
0.0617 1
0.0619 1
0.0620 1
0.0622 1
0.0623 1
0.0625 1
0.0626 1
0.0628 1
0.0629 1
0.0630 1
0.0632 1
0.0633 1
0.0634 1
0.0636 2
0.0637 2
0.0638 2
0.0639 2
0.0640 2
0.0642 2
0.0643 2
0.0644 2
0.0645 2
0.0646 2
0.0647 2
0.0648 2
0.0649 2
0.0650 2
0.0651 2
0.0652 2
0.0653 2
0.0654 2
0.0655 2
0.0656 2
0.0657 2
0.0658 2
M1418, Rev. 1 Page 14 of 24 0.0704 0.0705 0.0706 0.0708 0.0709 0.0710 0.0712 0.0713 0.0714 0.0716 0.0717 0.0718 0.0719 0.0721 0.0722 0.0722 0.0723 0.0724 0.0725 0.0725 0.0726 0.0727 0.0727 0.0728 0.0729 0.0730 0.0730 0.0731 0.0732 0.0733 0.0733 0.0734 0.0735
- 0.0735 0.0736 0.0737
1.2 361.27 456.08 2.649E+02 1.225 365.68 458.53 2.652E+02 1.25 370.09 460.98 2.655E+02 1.275 374.50 463.43 2.658E+02 1.3 378.90 465.87 2.661E+02 1.325 383.29 468.31 2.664E+02 1.35 387.68 470.75 2.667E+02 1.375 392.06 473.18 2.670E+02 1.4 396.44 475.62 2.673E+02 1.425 400.81 478.05 2.676E+02 1.45 405.18 480.47 2.678E+02 1.475 409.54 482.90 2.681E+02 1.5 413.90 485.32 2.684E+02 1.525 418.25 487.73 2.686E+02 1.55 422.60 490.15 2.689E+02.
1.575 426.94 492.56 2.691E+02 1.6 431.28 494.97 2.694E+02 1.625 435.61 497.38 2.696E+02 1.65 439.94 499.79 2.699E+02 1.675 444.27 502.19 2.701E+02 1.7 448.59 504.59 2.704E+02 1.725 452.90 506.98 2.706E+02 1.75 457.21 509.38 2.708E+02 1.775 461.52 511.77 2.711E+02 1.8 465.82 514.16 2.713E+02 1.825 470.12 516.55 2.715E+02 1.85 474.42 518.94 2.717E+02 1.875 478.71 521.32 2.720E+02 1.9 482.99 523.70 2.722E+02 1.925 487.27 526.08 2.724E+02 1.95 491.55 528.46 2.726E+02 1.975 495.82 530.83 2.728E+02 2
500.09 533.20 2.730E+02 2.025 504.36 535.57 2.732E+02 2.05 508.62 537.94 2.734E+02 2.075 512.88 540.31 2.736E+02 1.108E+01 6.922E-12 275.95 1.114E+01 8.555E-12 276.32 1.120E+01 1.055E-11 276.70 1.126E+01 1.297E-11 277.06 1.132E+01 1.590E-11 277.43 1.138E+01 1.946E-11 277.78 1.144E+01 2.375E-11 278.14 1.150E+01 2.893E-11 278.48 1.156E+01 3.514E-11 278.83 1.162E+01 4.260E-11 279.17 1.168E+01 5.153E-11 279.50 1.173E+01 6.219E-11 279.83 1.179E+01 7.490E-11 280.16 1.185E+01 9.001 E-11 280.48 1.191E+01 1.079E-10 280.80 1.197E+01 1.292E-10 281.12 1.203E+01 1.543E-10 281.43 1.209E+01 1.840E-10 281.73 1.214E+01 2.189E-10 282.04 1.220E+01 2.600E-10 282.34 1.226E+01 3.082E-10 282.63 1.232E+01 3.647E-10 282.93 1.238E+01 4.308E-10 283.22 1.244E+01 5.079E-10 283.50 1.249E+01 5.978E-10 283.79 1.255E+01 7.024E-10 284.07 1.261E+01 8.240E-10 284.35 1.267E+01 9.649E-10 284.62 1.273E+01 1.128E-09 284.89 1.278E+01 1.317E-09 285.16 1.284E+01 1.535E-09 285.42 1.290E+01 1.786E-09 285.69 1.296E+01 2.075E-09 285.95 1.301 E+01 2.408E-09 286.20 1.307E+01 2.789E-09 286.46 1.313E+01 3.226E-09 286.71 0.0659 2
0.0660 2
0.0661 2
0.0662 2
0.0663 2
0.0663 2
0.0664 2
0.0665 2
0.0666 2
0.0667 2
0.0668 2
0.0668 2
0.0669 2
0.0670 2
0.0671 2
0.0671
- 2 0.0672 2
0.0673 2
0.0674 2
0.0674 2
0.0675 2
0.0676 2
0.0676 2
0.0677 2
0.0678 2
0.0678 2
0.0679 2
0.0680 2
0.0680 2
0.0681 2
0.0682 2
0.0682 2
0.0683 2
0.0684 2
0.0684 2
0.0685 2
M1418, Rev. 1 Page 15 of 24 0.0737 0.0738 0.0739 0.0740 0.0740 0.0741 0.0742 0.0742 0.0743 0.0744 0.0745 0.0745 0.0746 0.0747 0.0747 0.0748 0.0749 0.0749 0.0750 0.0751 0.0751 0.0752 0.0753 0.0754 0.0754 0.0755 0.0756 0.0756 0.0757 0.0758 0.0758 0.0759 0.0760 0.0760 0.0761 0.0762
2.1 517.14 542.67 2.738E+02 2.125 521.39 545.03 2.740E+02 2.15 525.63 547.39 2.741E+02 2.175 529.88 549.75 2.743E+02 2.2 534.12 552.10 2.745E+02 2.225 538.35 554.46 2.747E+02 2.25 542.59 556.81 2.749E+02 2.275 546.82 559.16 2.750E+02 2.3 551.04 561.51 2.752E+02 2.325 555.27 563.85 2.754E+02 2.35 559.48 566.20 2.756E+02 2.375 563.70 568.54 2.757E+02 2.4 567.91 570.88 2.759E+02 2.425 572.12 573.22 2.760E+02 2.45 576.33 575.55 2.762E+02 2.475 580.53 577.89 2.764E+02 2.5 584.39 580.03 2.765E+02 2.525 588.24 582.17 2.767E+02 2.55 592.10 584.32 2.768E+02 2.575 595.95 586.45 2.769E+02 2.6 599.80 588.59 2.771E+02 2.625 603.64 590.73 2.772E+02 2.65 607.48 592.86 2.773E+02 2.675 611.32 595.00 2.775E+02 2.7 615.16 597.13 2.776E+02 2.725 619.00 599.26 2.777E+02 2.75 622.83 601.39 2.779E+02 2.775 626.66 603.52 2.780E+02 2.8 630.48 605.64 2.781E+02 2.825 634.31 607.77 2.782E+02 2.85 638.13 609.89 2.784E+02 2.875 641.95 612.01 2.785E+02 2.9 645.77 614.13 2.786E+02 2.925 649.58 616.25 2.787E+02 2.95 653.40 618.37 2.788E+02 2.975 657.21 620.49 2.790E+02 1.319E+01 3.726E-09 286.96 1.324E+01 4.298E-09 287.20 1.330E+01 4.951E-09 287.45 1.336E+01 5.695E-09 287.69 1.342E+01 6.542E-09 287.93 1.347E+01 7.505E-09 288.16 1.353E+01 8.598E-09 288.40 1.359E+01 9.839E-09 288.63 1.364E+01 1.124E-08 288.86 1.370E+01 1.283E-08 289.09 1.376E+01 1.463E-08 289.31 1.382E+01 1.665E-08 289.54 1.387E+01 1.894E-08 289.76 1.393E+01 2.151 E-08 289.98 1.399E+01 2.440E-08 290.19 1.404E+01 2.766E-08 290.41 1.409E+01 3.099E-08 290.60 1.415E+01 3.470E-08 290.80 1.420E+01 3.881E-08 290.99 1.425E+01 4.337E-08 291.18 1.430E+01 4.842E-08 291.37 1.435E+01 5.401 E-08 291.56 1.441 E+01 6.020E-08 291.75 1.446E+01 6.703E-08 291.93 1.451 E+01 7.458E-08 292.11 1.456E+01 8.290E-08 292.30 1.461 E+01 9.207E-08 292.48 1.467E+01 1.022E-07 292.66 1.472E+01 1.133E-07 292.83 1.477E+01 1.255E-07 293.01 1.482E+01 1.390E-07 293.19 1.487E+01 1.537E-07 293.36 1.492E+01 1.699E-07 293.53 1.497E+01 1.876E-07 293.70 1.503E+01 2.071E-07 293.87 1.508E+01 2.283E-07 294.04 0.0685 2
0.0686 2
0.0687 2
0.0687 2
0.0688 2
0.0688 2
0.0689 2
0.0689 2
0.0690 2
0.0690 2
0.0691 2
0.0692 2
0.0692 2
0.0693 2
0.0693 2
0.0694 2
0.0694 2
0.0695 2
0.0695 2
0.0695 2
0.0696 2
0.0696 2
0.0697 2
0.0697 2
0.0698 2
0.0698 2
0.0699 2
0.0699 2
0.0699 2
0.0700 2
0.0700 2
0.0701 2
0.0701 2
0.0701 2
0.0702 2
0.0702 2
M1418, Rev. 1 Page 16 of 24 0.0762 0.0763 0.0764 0.0765 0.0765 0.0766 0.0767 0.0767 0.0768 0.0769 0.0769 0.0770 0.0771 0.0771 0.0772 0.0773 0.0773 0.0774 0.0775 0.0775 0.0776 0.0776 0.0777 0.0778 0.0778 0.0779 0.0779 0.0780 0.0781 0.0781 0.0782 0.0783 0.0783 0.0784 0.0784 0.0785
3 661.01 622.60 2.791E+02 1.513E+01 3.025 664.82 624.72 2.792E+02 1.518E+01 3.05 668.62 626.83 2.793E+02 1.523E+01 3.075 672.42 628.94 2.794E+02 1.528E+01 3.1 676.22 631.05 2.795E+02 1.533E+01 3.125 680.02 633.16 2.796E+02 1.539E+01 3.15 683.81 635.27 2.798E+02 1.544E+01 3.175 687.60 637.37 2.799E+02 1.549E+01 3.2 691.39 639.48 2.800E+02 1.554E+01 3.225 695.18 641.58 2.801E+02 1.559E+01 3.25 698.96 643.68 2.802E+02 1.564E+01 3.275 702.74 645.79 2.803E+02 1.569E+01 3.3 706.53 647.89 2.804E+02 1.574E+01 3.325 710.30 649.99 2.805E+02 1.579E+01 3.35 714.08 652.08 2.806E+02 1.585E+01 3.375 717.85 654.18 2.807E+02 1.590E+01 3.4 721.63 656.28 2.808E+02 1.595E+01 3.425 725.40 658.37 2.809E+02 1.600E+01 3.45 729.17 660.46 2.810E+02 1.605E+01 3.475 732.93 662.56 2.811E+02 1.610E+01 3.5 736.70 664.65 2.812E+02 1.615E+01 3.525 740.46 666.74 2.813E+02 1.620E+01 3.55 744.22 668.83 2.814E+02 1.625E+01 3.575 747.98 670.92 2.814E+02 1.630E+01 3.6 751.74 673.00 2.815E+02 1.635E+01 3.625 755.49 675.09 2.816E+02 1.640E+01 3.65 759.24 677.17 2.817E+02 1.646E+01 3.675 762.99 679.26 2.818E+02 1.651 E+01 3.7 766.74 681.34 2.819E+02 1.656E+01 3.725 770.49 683.42 2.820E+02 1.661 E+01 3.75 774.24 685.50 2.821E+02 1.666E+01 3.775 777.98 687.58 2.822E+02 1.671E+01 3.8 781.72 689.66 2.822E+02 1.676E+01 3.825 785.46 691.74 2.823E+02 1.681 E+01 3.85 789.20 693.82 2.824E+02 1.686E+01 3.875 792.93 695.89 2.825E+02 1.691 E+01 2.516E-07 294.21 2.771E-07 294.38 3.048E-07 294.54 3.352E-07 294.70 3.683E-07 294.87 4.043E-07 295.03 4.436E-07 295.19 4.864E-07 295.35 5.329E-07 295.51 5.835E-07 295.66 6.385E-07 295.82 6.982E-07
.295.97 7.629E-07 296.13 8.332E-07 296.28 9.093E-07 296.43 9.918E-07 296.58 1.081 E-06 296.73 1.178E-06 296.88 1.282E-06 297.03 1.395E-06 297.18 1.517E-06 297.32 1.648E-06 297.47 1.790E-06 297.61 1.943E-06 297.75 2.108E-06 297.90 2.286E-06 298.04 2.477E-06 298.18 2.683E-06 298.32 2.904E-06 298.46 3.142E-06 298.59 3.398E-06 298.73 3.672E-06 298.87 3.966E-06 299.00 4.282E-06 299.14 4.620E-06 299.27 4.983E-06 299.40 0.0703 2
0.0703 2
0.0703 2
0.0704 2
0.0704 2
0.0705 2
0.0705 2
0.0705 2
0.0706 2
0.0706 3
0.0707 3
0.0707 3
0.0707 3
0.0708 3
0.0708 3
0.0708 3
0.0709 3
0.0709 3
0.0709 3
0.0710 3
0.0710 3
0.0710 3
0.0711 3
0.0711 3
0.0712 3
0.0712 3
0.0712 3
0.0713 3
0.0713 3
0.0713 3
0.0714 3
0.0714 3
0.0714 3
0.0714 3
0.0715 3
0.0715 3
M1418, Rev. 1 Page 17 of 24 0.0786 0.0786 0.0787 0.0787 0.0788 0.0789 0.0789 0.0790 0.0790 0.0791 0.0791 0.0792 0.0792 0.0793 0.0793 0.0794 0.0794 0.0795 0.0795 0.0796 0.0796 0.0797 0.0797 0.0798 0.0798 0.0799 0.0799 0.0800 0.0800 0.0801 0.0801 0.0802 0.0802 0.0803 0.0803 0.0804
3.9 796.67 697.97 2.826E+02 3.925 800.40 700.04 2.827E+02 3.95 804.13 702.11 2.827E+02 3.975 807.86 704.18 2.828E+02 4
811.59 706.25 2.829E+02*
4.025 815.31 708.32 2.830E+02 4.05 819.04 710.39 2.831E+02 4.075 822.76 712.46 2.831E+02 4.1 826.48 714.53 2.832E+02 4.125 830.20 716.59 2.833E+02*
4.15 833.91 718.66 2.834E+02 4.175 837.63 720.72 2.834E+02 4.2 841.34 722.78 2.835E+02 4.225 845.05 724.85 2.836E+02 4.25 848.76 726.91 2.836E+02 4.275 852.47 728.97 2.837E+02 4.3 856.18 731.03 2.838E+02 4.325 859.88 733.08 2.839E+02 4.35 863.59 735.14 2.839E+02 4.375 867.29 737.20 2.840E+02 4.4 870.99 739.25 2.841E+02 4.425 874.69 741.31 2.841E+02 4.45 878.38 743.36 2.842E+02 4.475 882.08 745.42 2.843E+02 4.5 885.77 747.47 2.843E+02 4.525 889.46
- 749.52 2.844E+02 4.55 893.15 751.57 2.845E+02 4.575 896.84 753.62 2.845E+02 4.6 900.53 755.67 2.846E+02 4.625 904.21 757.71 2.847E+02 4.65 907.90 759.76 2.847E+02 4.675 911.58 761.81 2.848E+02 4.7 915.26 763.85 2.849E+02 4.725 918.94 765.89 2.849E+02 4.75 922.62 767.94 2.850E+02 4.775 926.29 769.98 2.850E+02 1.696E+01 5.371 E-06 299.54 1.701E+01 5.787E-06 299.67 1.706E+01 6.232E-06 299.80 1.711 E+01 6.708E-06 299.93 1.716E+01 7.217E-06 300.06 1.721 E+01 7.760E-06 300.19 1.726E+01 8.341E-06 300.31 1.731 E+01 8.961E-06 300.44 1.736E+01 9.622E-06 300.57 1.741E+01 1.033E-05 300.69 1.746E+01 1.108E-05 300.82 1.751 E+01 1.188E-05 300.94 1.756E+01 1.273E-05 301.07 1.761 E+01 1.364E-05 301.19 1.766E+01 1.461 E-05 301.31 1.771 E+01 1.564E-05 301.43 1.776E+01 1.674E-05 301.56 1.781 E+01 1.790E-05 301.68 1.786E+01 1.914E-05 301.80 1.791 E+01 2.045E-05 301.91 1.796E+01 2.184E-05 302.03 1.801 E+01 2.332E-05 302.15 1.806E+01 2.489E-05 302.27 1.811 E+01 2.656E-05 302.39 1.816E+01 2.832E-05 302.50 1.821 E+01 3.020E-05 302.62 1.826E+01 3.218E-05 302.73 1.831 E+01 3.428E-05 302.85 1.836E+01 3.650E-05 302.96 1.841 E+01 3.885E-05 303.07 1.846E+01 4.133E-05 303.19 1.851 E+01 4.396E-05 303.30 1.856E+01 4.674E-05 303.41 1.861 E+01 4.968E-05 303.52 1.866E+01 5.278E-05 303.63 1.871 E+01 5.605E-05 303.74 0.0715 3
0.0716 3
0.0716 3
0.0716 3
0.0717 3
0.0717 3
0.0717 3
0.0718 3
0.0718 3
0.0718 3
0.0718 3
0.0719 3
0.0719 3
0.0719 3
0.0720 3
0.0720 3
0.0720 3
0.0721 3
0.0721 3
0.0721 3
0.0721 3
0.0722 3
0.0722 3
0.0722 3
0.0723 3
0.0723 3
0.0723 3
0.0723 3
0.0724 3
0.0724 3
0.0724 3
0.0724 3
0.0725 3
0.0725 3
0.0725 3
0.0725 3
M1418, Rev. 1 Page 18 of 24 0.0804 0.0805 0.0805 0.0806 0.0806 0.0807 0.0807 0.0808 0.0808 0.0808 0.0809 0.0809 0.0810 0.0810 0.0811 0.0811 0.0812 0.0812 0.0813 0.0813 0.0814 0.0814 0.0815 0.0815 0.0816 0.0816 0.0817 0.0817 0.0818 0.0818 0.0819 0.0819 0.0820 0.0820 0.0820 0.0821
4.8 929.97 772.02 2.851E+02 4.825 933.64 774.06 2.852E+02 4.85 937.31 776.10 2.852E+02 4.875 940.98 778.14 2.853E+02 4.9 944.65 780.18 2.853E+02 4.925 948.32 782.22 2.854E+02 4.95 951.98 784.25 2.854E+o2*
4.975 955.65 786.29 2.855E+02 5
959.31 788.32 2.856E+02 5.025 962.97 790.36 2.856E+02 5.05 966.63 792.39 2.857E+02 5.075 970.29 794.42 2.857E+02 5.1 973.94 796.45 2.858E+02 5.125 977.60 798.48 2.858E+02 5.15 981.25 800.51 2.859E+02 5.175 984.90 802.54 2.859E+02 5.2 988.55 804.57 2.860E+02 5.225 992.20 806.60 2.860E+02 5.25 995.85 808.62 2.861E+02 5.275 999.50 810.65 2.862E+02 5.3 1003.14 812.67 2.862E+02 5.325 1006.79 814.70 2.863E+02 5.35 1010.43 816.72 2.863E+02 5.375 1014.07 818.74 2.864E+02 5.4 1017.71 820.77 2.864E+02 5.425 1021.35 822.79 2.865E+02 5.45 1024.98 824.81 2.865E+02 5.475 1028.62 826.83 2.866E+02 5.5 1032.25 828.85 2.866E+02 5.525 1035.88 830.86 2.866E+02 5.55 1039.52 832.88 2.867E+02 5.575 1043.14 834.90 2.867E+02 5.6 1046.77 836.91 2.868E+02 5.625 1050.40 838.93 2.868E+02 5.65 1054.03 840.94 2.869E+02 5.675 1057.65 842.96 2.869E+02 1.876E+01 5.951E-05 303.85 1.881 E+01 6.316E-05 303.96 1.886E+01 6.700E-05 304.07 1.891 E+01 7.106E-05 304.18 1.896E+01 7.534E-05 304.29 1.901 E+01 7.984E-05 304.40 1.906E+01 8.459E-05 304.50 1.911 E+01 8.959E-05 304.61 1.916E+01 9.486E-05 304.71 1.921 E+01 1.004E-04 304.82 1.926E+01 1.062E-04 304.92 1.930E+01 1.124E-04 305.03 1.935E+01 1.188E-04 305.13 1.940E+01 1.256E-04 305.24 1.945E+01 1.327E-04 305.34 1.950E+01 1.402E-04 305.44 1.955E+01 1.480E-04 305.55 1.960E+01 1.563E-04 305.65 1.965E+01
.1.649E-04 305.75 1.970E+01 1.740E-04 305.85 1.975E+01 1.836E-04 305.95 1.980E+01 1.935E-04 306.05 1.985E+01 2.040E-04 306.15 1.990E+01 2.150E-04 306.25 1.994E+01 2.265E-04 306.35 1.999E+01 2.386E-04 306.45 2.004E+01 2.512E-04 306.55 2.009E+01 2.644E-04 306.64 2.014E+01 2.782E-04 306.74 2.019E+01 2.927E-04 306.84 2.024E+01 3.079E-04 306.93 2.029E+01 3.237E-04 307.03 2.034E+01 3.403E-04 307.13 2.039E+01 3.576E-04 307.22 2.043E+01 3.757E-04 307.32 2.048E+01 3.946E-04 307.41 0.0726 3
0.0726 3
0.0726 3
0.0727 3
0.0727 3
0.0727 3
0.0727 3
0.0728 3
0.0728 3
0.0728 3
0.0728 3
0.0729 3
0.0729 3
0.0729 3
0.0729 3
0.0730 3
0.0730 3
0.0730 3
0.0730 3
0.0731 3
0.0731 3
0.0731 3
0.0731 3
0.0731 3
0.0732 3
0.0732 3
0.0732 3
0.0732 3
0.0733 3
0.0733 3
0.0733 3
0.0733 3
0.0734 3
0.0734 3
0.0734 3
0.0734 3
M1418, Rev. 1 Page 19 of 24 0.0821 0.0822 0.0822 0.0823 0.0823 0.0824 0.0824 0.0825 0.0825 0.0826 0.0826 0.0827 0.0827 0.0828 0.0828 0.0829 0.0829 0.0829 0.0830 0.0830 0.0831 0.0831 0.0832 0.0832 0.0833 0.0833 0.0834 0.0834 0.0835 0.0835 0.0836 0.0836 0.0837 0.0837 0.0838 0.0838
5.7 1061.27 844.97 2.870E+02 5.725 1064.89 846.98 2.870E+02 5.75 1068.51 848.99 2.871E+02 5.775 1072.13 851.00 2.871E+02 5.8 1075.75 853.01 2.872E+02 5.825 1079.37 855.02 2.872E+02 5.85 1082.98 857.03 2.872E+02 5.875 1086.59 859.04 2.873E+02 5.9 1090.21 861.04 2.873E+02 5.925 1093.82 863.05 2.874E+02 5.95 1097.43 865.05 2.874E+02 5.975 1101.03 867.06 2.875E+02 6
1104.64 869.06 2.875E+02 6.025 1108.25 871.06 2.875E+02 6.05 1111.85 873.07 2.876E+02 6.075 1115.45 875.07 2.876E+02 6.1 1119.06 877.07 2.877E+02 6.125 1122.66 879.07 2.877E+02 6.15 1126.25 881.07 2.877E+02 6.175 1129.85 883.07 2.878E+02 6.2 1133.45 885.07 2.878E+02 6.225 1137.04 887.06 2.879E+02 6.25 1140.64 889.06 2.879E+02 6.275 1144.23 891.06 2.879E+02*
6.3 1147.82 893.05 2.880E+02 6.325 1151.41 895.05 2.880E+02 6.35 1155.00 897.04 2.881E+02 6.375 1158.59 899.03 2.881E+02 6.4 1162.18 901.03 2.881E+02 6.425 1165.76 903.02 2.882E+02 6.45 1169.35 905.01 2.882E+02 6.475 1172.93 907.00 2.882E+02 6.5 1176.51 908.99 2.883E+02 6.525 1180.09 910.98 2.883E+02 6.55 1183.67 912.97 2.883E+02 6.575 1187.25 914.95 2.884E+02 2.053E+01 4.143E-04 307.51 2.058E+01 4.349E-04 307.60 2.063E+01 4.564E-04 307.69 2.068E+01 4.789E-04 307.79 2.073E+01 5.023E-04 307.88 2.078E+01 5.268E-04 307.97 2.083E+01 5.523E-04 308.07 2.087E+01 5.789E-04 308.16 2.092E+01 6.066E-04 308.25 2.097E+01 6.355E-04 308.34 2.102E+01 6.657E-04 308.43 2.107E+01 6.970E-04 308.52 2.112E+01 7.297E-04 308.61 2.117E+01 7.638E-04 308.70 2.122E+01 7.992E-04 308.79 2.126E+01 8.361E-04 308.88 2.131 E+01 8.745E-04 308.97 2.136E+01 9.144E-04 309.06 2.141 E+01 9.559E-04 309.15 2.146E+01 9.991E-04 309.24 2.151E+01 1.044E-03 309.33 2.156E+01 1.091 E-03 309.42 2.160E+01 1.139E-03 309.50 2.165E+01 1.190E-03 309.59 2.170E+01 1.242E-03 309.68 2.175E+01 1.296E-03 309.76 2.180E+01 1.353E-03 309.85 2.185E+01 1.412E-03 309.94 2.189E+01 1.472E-03 310.02 2.194E+01 1.536E-03 310.11 2.199E+01 1.601 E-03 310.19 2.204E+01 1.669E-03 310.28 2.209E+01 1.740E-03 310.36 2.214E+01 1.813E-03 310.45 2.219E+01 1.889E-03 310.53 2.223E+01 1.967E-03 310.62 0.0734 3
0.0735 3
0.0735 3
0.0735 3
0.0735 3
0.0736 3
0.0736 3
0.0736 3
0.0736 3
0.0736 3
0.0737 3
0.0737 3
0.0737 3
0.0737 3
0.0738 3
0.0738 3
0.0738 3
0.0738 3
0.0738 3
0.0739 3
0.0739 3
0.0739 3
0.0739 3
0.0739 3
0.0740 3
0.0740 3
0.0740 3
0.0740 3
0.0740 3
0.0741 3
0.0741 3
0.0741 3
0.0741 3
0.0741 3
0.0742 3
0.0742 3
M1418, Rev. 1 Page 20 of 24 0.0838 0.0839 0.0839 0.0840 0.0840 0.0841 0.0841 0.0842 0.0842 0.0843 0.0843 0.0844 0.0844 0.0845 0.0845 0.0845 0.0846 0.0846 0.0847 0.0847 0.0848 0.0848 0.0849 0.0849 0.0850 0.0850 0.0851 0.0851 0.0852 0.0852 0.0852 0.0853 0.0853 0.0854 0.0854 0.0855
6.6 1190.82 916.94 2.884E+02 6.625 1194.40 918.93 2.885E+02 6.65 1197.97 920.91 2.885E+02 6.675 1201.55 922.90 2.885E+02 6.7 1205.12 924.88 2.886E+02 6.725 1208.69 926.87 2.886E+02 6.75 1212.26 928.85 2.886E+02 6.775 1215.83 930.83 2.887E+02 6.8 1219.39 932.81 2.887E+02 6.825 1222.96 934.79 2.887E+02 6.85 1226.52 936.77 2.888E+02 6.875 1230.09 938.75 2.888E+02 6.9 1233.65 940.73 2.888E+02 6.925 1237.21 942.71 2.889E+02 6.95 1240.77 944.69 2.889E+02 6.975 1244.33 946.67 2.889E+02 7
1247.89 948.64 2.890E+02 7.025 1251.44 950.62 2.890E+02 7.05 1255.00 952.59 2.890E+02 7.075 1258.55 954.57 2.890E+02 7.1 1262.11 956.54 2.891E+02 7.125 1265.66 958.51 2.891E+02 7.15 1269.21 960.49 2.891E+02 7.175 1272.76 962.46 2.892E+02 7.2 1276.31 964.43 2.892E+02 7.225 1279.85 966.40 2.892E+02 7.25 1283.40 968.37 2.893E+02 7.275 1286.94 970.34 2.893E+02 7.3 1290.49 972.31 2.893E+02 7.325 1294.03 974.28 2.893E+02 7.35 1297.57 976.24 2.894E+02 7.375 1301.11 978.21 2.894E+02 7.4 1304.65 980.18 2.894E+02 7.425 1308.19 982.14 2.895E+02 7.45 1311.73 984.11 2.895E+02 7.475 1315.26 986.07 2.895E+02 2.228E+01 2.049E-03 310.70 2.233E+01 2.133E-03 310.78 2.238E+01 2.221 E-03 310.87 2.243E+01 2.311 E-03 310.95 2.247E+01 2.405E-03 311.03 2.252E+01 2.502E-03 311.11 2.257E+01 2.603E-03 311.20 2.262E+01 2.707E-03 311.28 2.267E+01 2.815E-03 311.36 2.272E+01 2.926E-03 311.44 2.276E+01 3.042E-03 311.52 2.281E+01 3.161 E-03 311.60 2.286E+01 3.284E-03 311.69 2.291 E+01 3.412E-03 311.77 2.296E+01 3.544E-03 311.85 2.300E+01 3.680E-03 311.93 2.305E+01 3.821E-03 312.01 2.310E+01 3.967E-03 312.09 2.315E+01 4.117E-03 312.17 2.320E+01 4.273E-03 312.25 2.324E+01 4.433E-03 312.33 2.329E+01 4.599E-03 312.40 2.334E+01 4.770E-03 312.48 2.339E+01 4.947E-03 312.56 2.344E+01 5.129E-03 312.64 2.348E+01 5.317E-03 312.72 2.353E+01 5.511 E-03 312.80 2.358E+01 5.711 E-03 312.87 2.363E+01 5.918E-03 312.95 2.367E+01 6.131 E-03 313.03 2.372E+01 6.350E-03 313.11 2.377E+01 6.577E-03 313.18 2.382E+01 6.810E-03 313.26 2.387E+01 7.051E-03 313.34 2.391E+01 7.299E-03 313.41 2.396E+01 7.554E-03 313.49 0.0742 3
0.0742 3
0.0742 3
0.0743 3
0.0743 3
0.0743 3
0.0743 3
0.0743 3
0.0744 3
0.0744 3
0.0744 3
0.0744 3
0.0744 3
0.0745 3
0.0745 3
0.0745 3
0.0745 3
0.0745 3
0.0746 3
0.0746 3
0.0746 3
0.0746 3
0.0746 3
0.0747 3
0.0747 3
0.0747 3
0.0747 3
0.0747 3
0.0747 3
0.0748 3
0.0748 3
0.0748 3
0.0748 3
0.0748 3
0.0749 3
0.0749 3
M1418, Rev. 1 Page 21 of 24 0.0855 0.0856 0.0856 0.0857 0.0857 0.0858 0.0858 0.0859 0.0859 0.0859 0.0860 0.0860 0.0861 0.0861 0.0862 0.0862 0.0863 0.0863 0.0864 0.0864 0.0865 0.0865 0.0865 0.0866 0.0866 0.0867 0.0867 0.0868 0.0868 0.0869 0.0869 0.0870 0.0870 0.0870 0.0871 0.0871
7.5 1318.80 988.04 2.895E+02 7.525 1322.33 990.00 2.896E+02 7.55 1325.86 991.96 2.896E+02 7.575 1329.39 993.92 2.896E+02 7.6 1332.92 995.89 2.897E+02 7.625 1336.45 997.85 2.897E+02 7.65 1339.98 999.81 2.897E+02 7.675 1343.51 1001.76 2.897E+02 7.7 1347.03 1003.72 2.898E+02 7.725 1350.56 1005.68 2.898E+02 7.75 1354.08 1007.64 2.898E+02 7.775 1357.60 1009.60 2.898E+02 7.8 1361.12 1011.55 2.899E+02 7.825 1364.65 1013.51 2.899E+02 7.85 1368.16 1015.46 2.899E+02 7.875 1371.68 1017.42 2.899E+02 7.9 1375.20 1019.37 2.900E+02 7.925 1378.72 1021.33 2.900E+02 7.95 1382.23 1023.28 2.900E+02 7.975 1385.74 1025.23 2.901E+02 8
1389.26 1027.18 2.901E+02 8.025 1392.77 1029.13 2.901E+02 8.05 1396.28 1031.08 2.901E+02 8.075 1399.79 1033.03 2.901E+02 8.1 1403.30 1034.98 2.902E+02 8.125 1406.80 1036.93 2.902E+02 8.15 1410.31 1038.88 2.902E+02 8.175 1413.82 1040.83 2.902E+02 8.2 1417.32 1042.77 2.903E+02 8.225 1420.82 1044.72 2.903E+02 8.25 1424.33 1046.66 2.903E+02 8.275 1427.83 1048.61 2.903E+02 8.3 1431.33 1050.55 2.904E+02 8.325 1434.83 1052.50 2.904E+02 8.35 1438.32 1054.44 2.904E+02 8.375 1441.82 1056.38 2.904E+02 2.401 E+01 7.818E-03 313.57 2.406E+01 8.089E-03 313.64 2.410E+01 8.368E-03 313.72 2.415E+01 8.656E-03 313.79 2.420E+01 8.952E-03 313.87 2.425E+01 9.257E-03 313.94 2.430E+01 9.570E-03 314.02 2.434E+01 9.893E-03 314.09 2.439E+01 1.023E-02 314.17 2.444E+01 1.057E-02 314.24 2.449E+01 1.092E-02 314.32 2.453E+01 1.128E-02 314.39 2.458E+01 1.165E-02 314.46 2.463E+01 1.204E-02 314.54 2.468E+01 1.243E-02 314.61 2.472E+01 1.283E-02 314.69 2.477E+01 1.325E-02 314.76 2.482E+01 1.368E-02 314.83 2.487E+01 1.412E-02 314.91 2.491E+01 1.457E-02 314.98 2.496E+01 1.503E-02 315.05 2.501E+01 1.551 E-02 315.12 2.506E+01 1.600E-02 315.20 2.510E+01 1.650E-02 315.27 2.515E+01 1.702E-02 315.34 2.520E+01 1.755E-02 315.41 2.524E+01 1.809E-02 315.48 2.529E+01 1.865E-02 315.56 2.534E+01 1.922E-02 315.63 2.539E+01 1.981 E-02 315.70 2.543E+01 2.042E-02 315.77 2.548E+01 2.104E-02 315.84 2.553E+01 2.167E-02 315.91 2.558E+01 2.233E-02 315.98 2.562E+01 2.299E-02 316.06 2.567E+01 2.368E-02 316.13 0.0749 3
0.0749 3
0.0749 3
0.0749 3
0.0750 3
0.0750 3
0.0750 3
0.0750 3
0.0750 3
0.0751 3
0.0751 3
0.0751 3
0.0751 3
0.0751 3
0.0751 3
0.0752 3
0.0752 3
0.0752 3
0.0752 3
0.0752 3
0.0752 3
0.0753 3
0.0753 3
0.0753 3
0.0753 3
0.0753 3
0.0754 3
0.0754 3
0.0754 3
0.0754 3
0.0754 3
0.0754 3
0.0755 3
0.0755 3
0.0755 3
0.0755 3
M1418, Rev. 1 Page 22 of 24 0.0872 0.0872 0.0873 0.0873 0.0874 0.0874 0.0875 0.0875 0.0876 0.0876 0.0876 0.0877 0.0877 0.0878 0.0878 0.0879 0.0879 0.0880 0.0880 0.0881 0.0881 0.0881 0.0882 0.0882 0.0883 0.0883 0.0884 0.0884 0.0885 0.0885 0.0886 0.0886 0.0886 0.0887 0.0887 0.0888
8.4 1445.32 1058.33 2.905E+02 8.425 1448.81 1060.27 2.905E+02 8.45 1452.30 1062.21 2.905E+02 8.475 1455.80 1064.15 2.905E+02 8.5 1459.29 1066.09 2.905E+02 8.525 1462.78 1068.03 2.906E+02 8.55 1466.27 1069.97 2.906E+02 8.575 1469.76 1071.90 2.906E+02 8.6 1473.25 1073.84 2.906E+02 8.625 1476.73 1075.78 2.907E+02 8.65 1480.22 1077.72 2.907E+o2*
8.675 1483.70 1079.65 2.907E+02 8.7 1487.18 1081.59 2.907E+02 8.725 1490.67 1083.52 2.907E+02 8.75 1494.15 1085.45 2.908E+02 8.775 1497.63 1087.39 2.908E+02 8.8 1501.11 1089.32 2.908E+02 8.825 1504.59 1091.25 2.908E+02 8.85 1507.94 1093.12 2.908E+02 8.875 1511.13 1094.89 2.909E+02 8.9 1514.31 1096.65 2.909E+02 8.925 1517.47 1098.41 2.909E+02 8.95 1520.61 1100.16 2.909E+02 8.975 1523.74 1101.89 2.909E+02 9
1526.85 1103.62 2.910E+02 9.025 1529.95 1105.34 2.910E+02 9.05 1533.03 1107.06 2.910E+02 9.075 1536.10 1108.76 2.910E+02 9.1 1539.15 1110.46 2.910E+02 9.125 1542.19 1112.15 2.910E+02 9.15 1545.22 1113.83 2.911E+02 9.175 1548.23 1115.50 2.911E+02 9.2 1551.24 1117.17 2.911E+02 9.225 1554.25 1118.85 2.911 E+02 9.25 1557.25 1120.51 2.911E+02 9.275 1560.25 1122.18 2.911E+02 2.572E+01 2.438E-02 316.20 2.576E+01 2.510E-02 316.27 2.581 E+01 2.584E-02 316.34 2.586E+01 2.660E-02 316.41 2.591E+01 2.738E-02 316.48 2.595E+01 2.818E-02 316.55 2.600E+01 2.899E-02 316.62 2.605E+01 2.983E-02 316.69 2.609E+01 3.068E-02 316.76 2.614E+01 3.156E-02 316.83 2.619E+01 3.246E-02 316.90 2.624E+01 3.338E-02 316.97 2.628E+01 3.432E-02 317.03 2.633E+01 3.529E-02 317.10 2.638E+01 3.628E-02 317.17 2.642E+01 3.729E-02 317.24 2.647E+01 3.833E-02 317.31 2.652E+01 3.939E-02 317.38 2.656E+01 4.043E-02 317.44 2.661 E+01 4.145E-02 317.51 2.665E+01 4.248E-02 317.57 2.669E+01 4.354E-02 317.63 2.673E+01 4.460E-02 317.69 2.678E+01 4.569E-02 317.76 2.682E+01 4.679E-02 317.82 2.686E+01 4.791 E-02 317.88 2.690E+01 4.905E-02 317.94 2.694E+01 5.020E-02 318.00 2.698E+01 5.137E-02 318.06 2.703E+01 5.256E-02 318.12 2.707E+01 5.377E-02 318.17 2.711E+01 5.500E-02 318.23 2.715E+01 5.625E-02 318.29 2.719E+01 5.752E-02 318.35 2.723E+01 5.881E-02 318.41 2.727E+01 6.013E-02 318.47 0.0755 3
0.0755 3
0.0756 3
0.0756 3
0.0756 3
0.0756 3
0.0756 3
0.0756 3
0.0757 3
0.0757 3
0.0757 3
0.0757 3
0.0757 3
0.0757 3
0.0758 3
0.0758 3
0.0758 3
0.0758 4
0.0758 5
0.0758 5
0.0759 5
0.0759 5
0.0759 5
0.0759 5
0.0759 5
0.0759 5
0.0759 5
0.0760 5
0.0760 5
0.0760 5
0.0760 6
0.0760 6
0.0760 6
0.0760 6
0.0761 6
0.0761 6
M1418, Rev. 1 Page 23 of 24 0.0888 0.0889 0.0889 0.0890 0.0890 0.0891 0.0891 0.0891 0.0892 0.0892 0.0893 0.0893 0.0894 0.0894 0.0895 0.0895 0.0896 0.1022 0.1200 0.1219 0.1237 0.1256 0.1274 0.1292 0.1311 0.1329 0.1347 0.1365 0.1382 0.1400 0.1412 0.1417 0.1422 0.1427 0.1432 0.1437
9.3 1563.25 1123.84 2.912E+02 2.731 E+01 9.325 1566.24 1125.51 2.912E+02 2.735E+01 9.35 1569.23 1127.16 2.912E+02 2.739E+01 9.375 1572.21 1128.82 2.9121::+02 2.743E+01 9.4 1575.19 1130.48 2.912E+02 2.747E+01 9.425 1578.16 1132.13 2.912E+02 2.751 E+01 9.45 1581.13 1133.78 2.912E+02 2.755E+01 9.475 1584.09 1135.42 2.913E+02 2.759E+01 9.5 1587.04 1137.06 2.913E+02 2.763E+01 9.525 1589.97 1138.69 2.913E+02 2.767E+01 9.55 1592.89 1140.31 2.913E+02 2.771 E+01 9.575 1595.79 1141.92 2.913E+02 2.775E+01 9.6 1598.67 1143.52 2.913E+02 2.779E+01 9.625 1601.55 1145.12 2.914E+02 2.783E+01 9.65 1604.41 1146.71 2.914E+02 2.787E+01 9.675 1607.25 1148.29 2.914E+02 2.790E+01 9.7 1610.08 1149.86 2.914E+02 2.794E+01 9.725 1612.90 1151.43 2.914E+02 2.798E+01 9.75 1615.70 1152.99 2.914E+02 2.802E+01 9.775 1618.49 1154.54 2.914E+02 2.806E+01 9.8 1621.27 1156.08 2.915E+02 2.809E+01 9.825 1624.04 1157.62 2.915E+02 2.813E+01 9.85 1626.80 1159.15 2.915E+02 2.817E+01 9.875 1629.54 1160.67 2.915E+02 2.820E+01 9.9 1632.27 1162.19 2.915E+02 2.824E+01 9.925 1635.00 1163.70 2.915E+02. 2.828E+01 9.95 1637.71 1165.21 2.915E+02 2.831 E+01 9.975 1640.40 1166.71 2.915E+02 2.835E+01 10 1643.09 1168.20 2.916E+02 2.839E+01 10.025 1645.77 1169.69 2.916E+02 2.842E+01 10.05 1648.44 1171.17 2.916E+02 2.846E+01 10.075 1651.09 1172.65 2.916E+02 2.850E+01 10.1 1653.74 1174.12 2.916E+02 2.853E+01 6.147E-02 318.52 6.284E-02 318.58 6.423E-02 318.64 6.564E-02 318.70 6.708E-02 318.76 6.854E-02 318.81 7.003E-02 318.87 7.154E-02 318.93 7.307E-02 318.98 7.462E-02 319.04 7.619E-02 319.10 7.778E-02 319.15 7.939E-02 319.21 8.102E-02 319.26 8.267E-02 319.32 8.434E-02 319.37 8.603E-02 319.43 8.774E-02 319.48 8.948E-02 319.53 9.123E-02 319.59 9.300E-02 319.64 9.480E-02 319.69 9.662E-02 319.75 9.846E-02 319.80 1.003E-01 319.85 1.022E-01 319.90 1.041 E-01 319.96 1.060E-01 320.01 1.080E-01 320.06 1.100E-01 320.11 1.120E~01 320.16 1.140E-01 320.21 1.160E-01 320.26 0.0761 6
0.0761 6
0.0761 6
0.0761 6
0.0761 6
0.0761 6
0.0762 7
0.0762 7
0.0762 7
0.0762 7
0.0762 7
0.0762 7
0.0762 7
0.0763 7
0.0763 7
0.0763 7
0.0763 7
0.0763 7
0.0763 7
0.0763 8
0.0763 8
0.0764 8
0.0764 8
0.0764 8
0.0764 8
0.0764 8
0.0764 8
0.0764 8
0.0764 8
0.0765 8
0.0765 8
0.0765 8
0.0765 9
M1418, Rev. 1 Page 24 of 24 0.1442 0.1447 0.1451 0.1456 0.1461 0.1466 0.1479 0.1499 0.1519 0.1540 0.1560 0.1580 0.1600 0.1619 0.1639 0.1659 0.1678 0.1698 0.1717 0.1735 0.1753 0.1771 0.1789 0.1806 0.1824 0.1841 0.1859 0.1876 0.1893 0.1911 0.1928 0.1945 0.1943 M1418, Rev. 1 Page 1 of 2 A SPECIAL W.ME1'A1.S INCONEL alloy X-750 (UNS N07750/W. Nr. 2.4669) is a precipitation-hardenable nickel-chromium alloy used for its corrosion and oxidation resistance and high strength at temperatures to 1300°F. Although much of the effect of precipitation hardening is lost with increasing temperature over 1300°F, heat-treated material has useful strength up to 1800°F. Alloy X-750 also has excellent properties down to cryogenic termperatures. Composition is shown in Table 1.
The economics of INCONEL alloy X-750 coupled with its availability in all standard mill forms has resulted in applications in a wide variety of industrial fields. In gas turbines, it is used for rotor blades and wheels, bolts, and other structural members. INCONEL alloy X-750 is used extensively in rocket-engine thrust chambers. Airframe applications include thrust reversers and hot-air ducting systems. Large pressure vessels are formed from INCONEL alloy X-750. Other applications are heat-treating fixtures, forming tools, extrusion dies, and test machine grips. For springs and fasteners, INCONEL alloy X-750 is used from sub-zero to 1200°F.
Depending on the application and the properties desired, various heat treatments are employed. For service above 1100°F, particularly where loads are to be sustained for long times, optimum properties are achieved by solution treating (2100°F) plus stabilization treating (1550°F) plus precipitation treating (1300°F).
For service below l 100°F, the alloy may be strengthened by precipitation treating after hot or cold working or by precipitation treating after equalizing or solution treating. A furnace-cooling treatment is also used to develop optimum properties for some applications.
The various heat treatments and the properties developed are described under the section on Mechanical Properties.
Property values in this bulletin - the results of extensive testing - are typical of the alloy but, unless shown as limiting, should not be used as specification values.
Publication No. SMC-067 Copyright© Special Metals Corporation, 2004 (Sept 04)
INCONEL, MONEL and NI-SPAN-C are trademarks of the Special Metals Corporation group of companies.
www.specialmetals.com Table 1 - Limiting Chemical Composition, %
Nickel (plus Cobalt).................................................... 70.00 min.
Chromium................................................................... 14.0-17.0 lron.................................................................................. 5.0-9.0 Titanium....................................................................... 2.25-2. 75 Aluminum.................................*.................................. 0.40-1.00 Niobium (plus Tantalum).............................................. O. 70-1.20 Manganese.............................................................*... 1.00 max.
Silicon......................................................................... 0.50 max.
Sulfur........................................................................... 0.01 max.
Copper........................................................................ 0.50 max.
Carbon........................................................................ 0.08 max.
Cobalt1......................................................................... 1.00 max
'Determination not required for routine acceptance.
Physical Constants and Thermal Properties Some. physical constants and thermal properties of INCONEL alloy X-750 are given in Tables 2 and 3.
Values for them1al expansion, thermal conductivity, specific heat, and diffusivity are from Lucks and Deem and electrical resistivity from tests conducted at Lehigh University.
Effects of temperature on modulus of elasticity and additional data on resistivity are in Tables 4 and 5. More modulus values can be found in the section on Mechanical Properties.
Table 2 - Physical Constants Density, lb/in3 ********************************************************************* 0.299 g/cm3 ********************************************************************** 8.28 Melting Range, 0 F..........................................*........... 2540-2600
°C.................................................... 1393-1427 Curie Temperature, °F As hot-rolled.............................................. -225 Triple-heat-treated (2100°F/2 hr, A.G.,+ 1500°F
/24 hr, A.G.,+ 1300°F/20 hr, A.C.)............. -193 Magnetic Permeability, 70°F, 200H As Hot-Rolled......................................... 1.0020 Triple-heat-treated {2100°F/2 hr, A.G.,+ 1500°F
/24 hr, A.G.,+ 1300°F/20 hr, A.C.)......... 1.0035 Emissivity, oxidized surface 600°F........................................................ 0.895 2000°F..................*......................*............ 0.925 Linear Contraction during Precipitation Treatment (1300°F/20 hr), in/in Hot-Rolled............................................ 0.00044 20% Cold-Rolled................................. 0.00052 Annealed.............................................. 0.00026 INCONEL alloy X-750 Table 3 - Thermal Propertiesa Mean Linear Thermal Temperature, Expansion, in.lin.rF x Conductivity, Specific Heat Of 1 o-a from 70° F to Btu/inJhr/sq ft/"F Btu/lbrF Temperature Shown
-250 6.5 67 0.073
-200 6.6 70 0.080
-100 6.7 74 0.090 70 83 0.103 200 7.0 89 0.109 400 7.2 98 0.116 600 7.5 109 0.120 800 7.8 120 0.125 1000 8.1 131 0.130 1200 8.4 143 0.137 1400 8.8 154 0.151 1600 9.3 164 0.171 1800 9.8
- Material heat-treated 2100°F/3 hr, A.G.,+ 1550'F/24 hr, A.G.,+ 1300°F/20 hr, A.G.
Table 4 - Effect of Heat Treatment on Room-Temperature Resistivity of Hot-Rolled Bar Heat Treatment As hot-rolled 2000°F/1 hr, A.C.
2100°F/1 hr, A.C.+1500"F/24 hr, A.C.+
1300°F/20 hr, A.C.
1800°F/1 hr, A.C.+1350°F/8 hr,F.C~ to 1150°F, hold at 1150°F for total time of 18 hr, A.C.
Resistivity, ohm/circ mil/ft 759 763 724 739 Temperature, "F
so*
500 1000 1200 1350 1500 1600 1800 Diffusivity, sq ft/hr 0.150 0.143 0.135 0.132 0.133 0.140 0.148 0.158 0.169 0.173 0.172 0.164 M1418, Rev. 1 Page 2 of 2 Electrical Resistivity, ohm/circ miVft 731 739 746 761 771 783 786 775 761 Table 5 - Modulus of Elasticity Modulus of Elasticity, 103 ksi Tension Torsion Static Dynamic Static 31.0 31.0 11.0 28.7 29.1 10.2 25.0 26.7 9.0 23.0 25.5 8.1 21.0 24.4 18.5 23.2 22.1 20.0
- Poisson's ratio = 0.29 Mechanical Properties INCONEL alloy X-750 may be given any one of a variety of heat treatments. Each develops special properties and puts the product form in the best condition for its intended application. In all conditions, alloy X-750 is resistant to oxidation up to 1800°F. The most often used heat treatments have been incorporated by the Society of Automotive Engineers in their AMS specifications* for variO\\lS product forms. The heat treatments, specifications, and product forms are summarized in Table 6.
- AMS specifications are subject to revision. The ones referenced in this publication were current when it was released. Publisher is the Society of Automotive Engineers, Inc.
2