NRC Update on Federal Regulatory Activities Affecting Industrial Radiography Anthony McMurtray Office of Nuclear Material Safety and Safeguards Division of Material Safety, State, Tribal, and Rulemaking Programs February 14, 2018

Topics

  • Electronic Dosimeters
  • Escalated Enforcement Actions 2

Electronic Dosimeters

Dosimetry Enforcement Discretion

  • RIS 2018-04 issued September 11, 2018 Notice of Issuance of Enforcement Guidance Memorandum Interim Guidance for Dispositioning Apparent Violations of 10 CFR Parts 34, 36, and 39 Requirements Resulting from the Use of Direct Ion Storage Dosimetry During Licensed Activities 4

10 CFR Part 34 Rulemaking

Individual Monitoring Devices Direct Final Rule

  • PRM 34-7: Rulemaking approved to go forward as a direct final rule by the NRC Commission on January 4, 2019
  • Regulatory basis associated with this rule should go out for public comment Spring/Summer 2019
  • Rule should be issued as final in 2020 6

Revised Radiation Safety Requirements Rule

  • PRM 34-6: Clarification to Training, Surveillance, and the Two Man Rule
  • Proposed Amendments in Rulemaking Plan to Part 34

- 34.41(a): two qualified individuals present, but second person no longer required to observe the operations

- 34.43: revise training requirements for radiographers and radiographers assistants regarding number of training hours

- 34.47: combined dosimetry devices

- 34.51: eliminate that the other individual present maintain continuous direct visual surveillance

  • Rulemaking plan associated with this rule should go to the NRC Commission in the Spring 2019 7

10 CFR Part 37 Activities

Current Part 37 Activities

  • NRC provided responses to the 2018 GAO Audit in January 2019

- Audit addressed implementation of Part 37 by NRC and Agreement State licensees

Regulatory Information Summaries (RIS)

  • RIS 2018-03 issued June 1, 2018 National Terrorism Advisory System and Protective Measures for the Physical Protection of Category 1 and Category 2 Quantities of Radioactive Material

10

Pending Commission Papers - Security

  • SECY-17-0083: Category 3 initiative - rulemaking recommendations

- Amend 10 CFR Parts 30, 40, and 70 to require safety and security equipment to be in place before granting a license for an unknown entity.

- Amend 10 CFR Parts 30, 40, and 70 to clarify license verification methods for transfers involving quantities of radioactive material below Category 2.

  • SECY-16-0115: Financial Assurance proposed rulemaking plan for Category 1 and 2 quantities of materials
  • Rulemaking aspects of these initiatives part of integrated rulemaking plan (SECY-17-0025) 11

Escalated Enforcement Actions

Industrial Radiography Escalated Enforcement

  • IA-16-049 [30.10(a)(1) and 34.41(a)]

- Deliberately failed to accompany another radiographer during radiographic operations at a temporary job site resulting in only one qualified individual at the site

  • IA-16-050 [30.10(a)(1), 34.31(a), 34.41(a) and 34.49(b)]

- Deliberately failed to perform operability checks to ensure that the drive cable for a radiographic exposure device was in good working condition prior to use

- Deliberately performed radiography with only one qualified individual present at the temporary job site

- Deliberately failed to conduct a survey of the radiographic exposure device after each radiographic exposure to determine that the source had returned to the shielded position 13

Industrial Radiography Escalated Enforcement

- Failure to perform operability checks to ensure that the drive cable for a radiographic exposure device was in good working condition prior to use

- Performed radiography with only one qualified individual present at the temporary job site

- Failure to conduct a survey of the radiographic exposure device after each radiographic exposure to determine that the source had returned to the shielded position 14

Industrial Radiography Escalated Enforcement EA-18-050 [34.31(a) and 150.20(b)(5)]

Failure to adequately perform visual and operability checks on a radiographic exposure device and associated equipment before use Guide tube disconnect occurred because the operability check did not ensure that the grease, dirt, and grime were cleared from the guide tube connection to the exposure device Failure to comply with all of the terms and conditions of the specific license issued by an Agreement State and failure to implement operating and emergency procedures 15

Materials Transportation Escalated Enforcement EA-17-101 [71.5(a) and 49 CFR 173]

Failure to package radioactive sources in a containment system securely closed by a positive fastening device that couldnt open during normal transport Failure to ensure that a package of Class 7 (radioactive) material was designed and prepared properly for shipment Although this issue didnt involve radiography, the violations associated with this event resulted in a Severity Level II citation and a $22,400 fine 16

Industrial Radiography Escalated Enforcement

Violations https://www.nrc.gov/reading-rm/doc-collections/enforcement/actions/

17

Questions?