Category:E-Mail
MONTHYEARML24002A7132023-12-29029 December 2023 Supplement - Peach Bottom Security Rule Exemption Request ISFSI Docket No. Reference (EPID L-2023-LLE-0032) (Updated) (Email) ML23352A3242023-12-18018 December 2023 Acceptance of Requested Licensing Action Request for Alternative Schedule to Complete Decommissioning Beyond 60 Years of Permanent Cessation of Operations (EPID L- 2023-LLN-0004) ML23331A9112023-11-22022 November 2023 Supplement - Peach Bottom Security Rule Exemption Request ISFSI Docket No. Reference ML23304A0182023-10-30030 October 2023 NRR E-mail Capture - Final RCI - Constellation Energy Generation, LLC - Peach Bottom 2 & 3 - Exemption from Security Rule (L-2023-LLE-0032) ML23264A7992023-09-21021 September 2023 NRR E-mail Capture - Final RAI - Constellation Energy Generation, LLC Fleet Request License Amendment Request to Adopt TSTF-580, Revision 1 ML23237B3972023-08-24024 August 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Alternative Request to Use Updated BWRVIP Guidelines ML23163A2292023-06-12012 June 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-580, Revision 1 ML22354A2622022-12-20020 December 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Request to Use Certain Provisions of the 2019 Edition of the ASME BPV Code, Section XI ML22325A0052022-11-18018 November 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of License Amendment Request to Adopt TSTF-273-A, Revision 2 ML22200A0782022-07-19019 July 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request to Use Honeywell Mururoa V4F1 R Supplied Air Suits ML22118A3312022-04-28028 April 2022 NRR E-mail Capture - Peach Bottom - Formal RAI for Proposed Alternative I5R-14, Revision 1 ML22041B5362022-02-10010 February 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541 ML22024A1852022-01-24024 January 2022 Acceptance for Review of Relief Request Associated with Reactor Pressure Vessel N-16A Nozzle Repair ML22020A0642022-01-13013 January 2022 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21301A0672021-10-28028 October 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-541 ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21252A0482021-09-0707 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Alternative Request for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21215A3502021-08-0303 August 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-554 ML21154A0142021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0132021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0112021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21144A2132021-05-24024 May 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21134A0152021-05-14014 May 2021 Acceptance Ventilation Filter Testing LAR ML21117A0442021-04-26026 April 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21084A2532021-03-24024 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Transfer Application ML21062A0652021-03-0101 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21049A2572021-02-18018 February 2021 Request for Additional Information Byron/Dresden Proposed Changes to Site Emergency Plans to Support Post-Shutdown and Permanently Defueled Conditions (EPID-2020-LLA-0240 & EPID-2020-LLA-0237) ML21091A1782021-02-0202 February 2021 Ti 2515/194 Inspection Documentation Request ML21033A8552021-02-0202 February 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Alternative Request to Expand the Use ASME Codes Cases N-878 and N-880 ML21012A1302021-01-12012 January 2021 Request for Additional Information - TSTF-505 ML20357A0972020-12-21021 December 2020 Request for Additional Information - TSTF-505 ML20350B5582020-12-14014 December 2020 NRR E-mail Capture - Exelon Generation Company, LLC -Alternative Request for Documentation of Replacement of Pressure Retaining Bolting ML20343A3492020-12-0707 December 2020 Acceptance of Requested Licensing Action: Peach Bottom Relief Request for N-16 Nozzle ML20324A6472020-11-19019 November 2020 Acceptance of Requested Licensing Action: Peach Bottom One-time Exemption App. B Sect. VI.C.3.(I)(1) Force on Force (COVID-19) ML20314A0282020-11-0606 November 2020 Verbal Relief for Penetration Nozzle ML20283A7722020-10-0909 October 2020 Submittal of Pennsylvania Letter Requesting Exemption from Biennial Exercise Requirements for Pennsylvania Nuclear Power Plants in Calendar Year 2020 ML20276A0762020-10-0202 October 2020 Acceptance of Requested Licensing Action, One-Time Acceptance for Review - Peach Bottom of Exemption from 10 CFR 50, Appendix E, Biennial Emergency Preparedness Exercise Requirements Due to COVID-19 Pandemic ML20266G3032020-09-22022 September 2020 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Request to Use Paragraph IWA-5120 of the 2017 Edition of the ASME B&PV Code, Section XI ML20239A7982020-08-25025 August 2020 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet License Amendment Request to Adopt TSTF-568, Revision 2 ML20217L3462020-08-0404 August 2020 Audit Plan Regarding License Amendment Request to Implement Riskinformed Extended Completion Times (L-2020-LLA-0120) ML20191A0182020-07-0101 July 2020 NRR E-mail Capture - Exelon Fleet RR for SPI for Appendix J Valves ML20178A1392020-06-26026 June 2020 Acceptance Review for Peach Bottom - License Amendment Request for TSTF-505 ML20153A7042020-06-0101 June 2020 NRR E-mail Capture - Preliminary RAI for Fleet Request to Use Alternative OMN-26 ML20149K4312020-05-22022 May 2020 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-566 ML20135H1972020-05-14014 May 2020 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Request to Extend Safety Relief Valve Test Interval ML20122A2302020-05-0101 May 2020 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of Fleet License Amendment Request to Adopt TSTF-566 ML20077F6112020-03-16016 March 2020 E-mail: the U.S. Nuclear Regulatory Commission'S Record of Decision Regarding Exelon'S Subsequent License Renewal Application for Peach Bottom Atomic Power Station Units 2 and 3 ML20070R2282020-03-10010 March 2020 Request for Additional Information - RR ML20063G1362020-02-27027 February 2020 NRR E-mail Capture - Exelon Generation Company, LLC -Acceptance of Proposed Alternative to Extend Safety Relief Valve Test Frequency (EPIDs L-2020-LLR-0014 Through L-2020-LLR-0018) ML20057E5562020-02-26026 February 2020 Availability of the Final Supplemental Environmental Impact Statement for Subsequent License Renewal of Peach Bottom Atomic Power Station, Units 2 and 3 2023-09-21
[Table view] |
Text
NRR-DMPSPEm Resource From: Sebrosky, Joseph Sent: Monday, February 11, 2019 3:07 PM To: 'Gropp Jr, Richard W:(GenCo-Nuc)'
Subject:
Clarification question associated with staff assessment of fragility portion of of Peach Bottom seismic probabilistic risk assessment report dated August 28, 2018 Mr. Gropp, By letter dated August 28, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18240A065), Exelon Generating Company, LLC (the licensee) provided its seismic probabilistic risk assessment (SPRA) report in response to Enclosure 1, item (8) of the March 12, 2012, 10 CFR 50.54(f) letter (ADAMS Accession No. ML12053A340) for Peach Bottom Atomic Power Station, Units 2 and 3 (Peach Bottom). By letter dated July 6, 2017 (ADAMS Accession No. ML17177A446), the NRC issued a generic audit plan and entered into the audit process described in Office Instruction LIC 111, Regulatory Audits, dated December 29, 2008 (ADAMS Accession No. ML082900195), to assist in the timely and efficient closure of activities associated with the 50.54(f) letter. To support the staffs audit of the August 28, 2018, SPRA report the staff has developed the clarification questions found below. After you have time to review the clarification questions, please let me know when you could support an audit phone call to discuss these questions.
Sincerely, Joe Sebrosky Senior Project Manager Division of Licensing Projects Office of Nuclear Reactor Regulation 301-415-1132 Plant: Peach Bottom Units 2 and 3 Submittal ML#: ML18240A065 F&O#: 5-16 Team Lead: Joe Sebrosky SR: SFR-A2 and SPR-C1 Reviewer:
Proposed RAI:
In response to F&O 5-16, a bounding analysis for structural fragility of Conowingo Dam is presented in EXLNPB018-REPT-014, Attachment 5. The report addressed the structural fragility of spillway piers that can lead to failure of the gates. Table 3 in the report shows that the potential failure of Gates and Power House and Intake were screened out, however, rationale for screening of these components were not documented. Spillway gates are typically steel structural system anchored to the spillway piers. The seismic and hydrodynamic loading on the gates during earthquake can cause failure of gate structure or exceed anchorage capacity during the transfer of load to the piers. Failure of gates, as pointed out in the report, can result in uncontrolled release from the reservoir and loss of 1
cooling water. Discuss the screening approach used for the gates and power house and intake structure and confirm that the structural fragility of the spillway pier is bounding for the Conowingo Dam.
Rationale/Need for RAI:
Decision:
2
Hearing Identifier: NRR_DMPS Email Number: 795 Mail Envelope Properties (BN6PR09MB129916C175C7B4ABBE8B9525F8640)
Subject:
Clarification question associated with staff assessment of fragility portion of of Peach Bottom seismic probabilistic risk assessment report dated August 28, 2018 Sent Date: 2/11/2019 3:07:22 PM Received Date: 2/11/2019 3:07:22 PM From: Sebrosky, Joseph Created By: Joseph.Sebrosky@nrc.gov Recipients:
"'Gropp Jr, Richard W:(GenCo-Nuc)'" <Richard.Gropp@exeloncorp.com>
Tracking Status: None Post Office: BN6PR09MB1299.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2415 2/11/2019 3:07:22 PM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received: