{{#Wiki_filter:PS~G* Public Service Electric and Gas Company Salem Nuclear Generating Station PO. Box #168 Hancocks Bridge, New Jersey 08038 April 7, 1978 Director Off ice of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

APPENDIX B TO OPERATING LICENSE DPR-70 ENVIRONMENTAL TECHNICAL SPECIFICATIONS SALEM GENERATING STATION FOR s:~ ~ OJ -;,q -... L ~ ~

tl en

~ ~:'~~.y, ..,t: _r 1 ):.r*~c1...,.. ~ ~~:!.1 ,:..;.(/> C? ~ -ri1 ~ Al 0 0 rri \\.;"1 U> f\\) In compliance with Section 5.6.1, Routine Reports, Salem Environmental Technical Specifications, enclosed are the following reports for the month of March, 1978.

1.

National Pollutant Discharge Elimination System. Discharge Monitoring Reports Permit No. NJ 0005622

2.

Operating Report of the Industrial Waste Treatment Plant.

3.

Waste Water Treatment Report. Sincerely yours, H. J. Heller i :*:~I ,_~._ ~.~~ i ~*1 r'.~1-< =~~.~j c::.r..-;i- ~~;:;; .. -r C::"A.l 2r=tii J,..,.... -*:..-:i cS

~~

Manager - Salem Generating Station JMZ:jcm Enclosures 32.3.31.Rl.SHP The Energy People 95-2189 (5M) 10-72

0 PS~G* Public Service Electric and Gas Company Salem Generating Station P. 0. Box #168 Hancocks Bridge. New Jersey 08038 April 6, 1978 Director, Division of Water Resources N. J. Department of Environmental Protection P. o. Box 2809 Trenton, New Jersey 08625 Attention: Delaware Basin

Dear Sir:

Attached is the Wastewater Treatment Report for the month of March, 1978 for the Sewage Treatment Plant at the Salem Generating Station. JMZ:jcm 16.5.18.Rl The Energy People Very truly yours, v/jJJ&:,__.,, L* H. J. Heller Manager - Salem Generating Station 95*2189 (2M) 10-76

WP-5 10-71 DELAWARE County: Salem NEW JERSEY STATE DEPARTMENT OF ENVIRONMENTAL PROTECTION DIVISION OF WATER RESOURCES BUREAU OF WATER POLLUTION CONTROL WASTEWATER TREATMENT REPORT Municipality: Lower Alloways Creek Township Name of Utility: PSE&G-Salem Generating Station Dav of the month 1 2 3 4 5 6 7 8 9 l n 11 i.,I 1 ll 1.411 i:;~ h. h 7 Im Ii a ?n '.>1 ')') '.>l Kece1v1ng Watercourse Design Flow: Plant Phone: 12,500 GPD (609) 365-7000 Month Hor c:-li 19 7% 24 ?t; '.>h. 27 ?Al 2ql lrJ lll :au~ Upstream from Effluent MGD 7776 "t'rpical value based on drainage area and averaqe rainfall Plant Effluent Flow for . t l.1 *' ~/ /../ (7 (7 24-hr Period 1000 G/D . {, /. 7.~.~. ' *' . (, *'. '. ' *' .~.~

  • 6.c.t.t.t.t *'

~t.t.(. 7'/ Pl.ant ErrJ.uent FJ.ow ~c !s ~, ~? I I '-1 l.7 ~; l.1 ~, 1., 1., ~, ~, 1.t ~7 ~, ~X' ~S' {7 (7 ~7 Maximum Rate 1000 G/D

  • ' *'.t 1.7

'7 *7 *' *' .t *' z..s-c rine immediah=>.r,) /.I

  • :I.. " /.'/ ~.~

,g }. 'I..s- *".l/ .'J.J )..S /.D .~ t

  • f ' '/ /.1.

~ dual mg/l developed l.7 I. l.. n.. c .J >J.* l.t 2.IJ ,,,9 t..t >'UJ )'l.t1 ')'J.o II.CJ >J." J.t7 ~1-~ /. 7 1..1.* 3 2,, 2.7 S udge Removed from ft3) ~ {r: Plant (Gals., lbs., "~ ~ d'<> i!I Setteable SoJ.ids Final Effluent mg/l i<.1 <.' -<./ -<.(.<./.(,( -<./ f(.1 <.I <.I.(,I -<./ -<.( <./ .{./ "*' <.J -{.( -<.I <.I.{.I Suspended Solids a., '),,~ 19 9 Final Effluent mq/l

  • '1'

~ '.2 B.O.D. Final ff ' '/ Effluent mg/l .:L.2.. Diss. 0 2.' 3.() ~J

  • u, 3., ~.1

~-~ '>.} 2.<f 1..7 /. 'i' /.) 1.r /./ 2,o/ /.t/ 1.9 I.;)... '*' COD 'ti' Other '2.1 Y7 Laboratory Fecal Coliform ..(:L ~Z- ":l. 33 '.rests IPH Lii 7.1 (.'1 (.2 t.£ t.7 ~1

t. c/ t.J.. t.!' 7./ 7.v

(.7 7.1 *z;, (.9 (.if,.J t.'i (.<{ zo Performed Temo. (OC) <;" 'lo 'lo 7#..,.r- </' ~" /(J(> /(/',/' ti' ttl 1z.',,.o_ 1:f Jr/~ 13~ Iv' "b,,_u 11/b llrs. Attend Lie. Op. 2_ 3

?_

~ .5 z at lant Other $' 8' ¥ 9' ~ ~ 8' s- ~ ~ 9' 8' i ¥ ff B' B' ff' 8 ? ~ Na ever y instance of tern p orar b Y ypa ssin f g o any units or interruption of disinfection and reason. Dates when outfall was dye tested and results Remarks: Plant not equipped with totalizing meter-effluent flow based on best estimate available.* /_ e 01 Mef'cr wits ""r \\IV'cnk1;._ ~,.,. .Jll a~ 3/;i.7. Number of Residential~~-- K. L. Homan Grade: s-2 Connections Apartments Re islf.l wnber: ---s---3-6_9_7 ____ _ and flow at Conunercial I hereby c b ~~o be ~or_r_e_c_t_t_o_t_h_e_b_e-st_o_f_m_y_kn-,9-w_l_e_d_g_e-.J end of month Industrial Signed:/ ,/:lt:dr.j

Title:

-5uPr

,ru G{kfa-U,e
-
  • 1'his *report is to be forwarded on or before the 10th of the following that for which the report is made out, to the NEW JERSEY STATE DEPARTMENT OF ENVIRONMENTAL PROTECTION, Bureau of Water Pollution Control, *P.O. Box 1390, Trenton, NJ 08625

I .. e OPS~G Public Service Electric and Gas Company Salem Nuclear Generating Station P.O. Box# 168 Hancocks Bridge, New Jersey 08038 Status of Compliance Branch Enforcement Division U.S. Environmental Protection Agency Region II 26 Federal Plaza New York, New York 10007 April 6, 1978 Attention: Dr. Richard A. Baker, Chief

Dear Sir:

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM DISCHARGE MONITORING REPORTS SALEM NUCLEAR GENERATING STATION PERMIT NO. NJ 0005622 Attached are the Discharging Monitoring Reports for Salem Nuclear Generating Station containing the information, as outlined in Permit No. NJ 0005622 for the ~onth of March, 1978 Very truly yours, ~J4t~ H. J." Heller Manager - Salem Generating Station JMZ:jcm CC: Director, Division of Water Resources (N.J. Dept. of Env. Pro.) General Manager - Electric Production Director, Office of Nuclear Reactor Regulation, USNRC, Washington, D.C. 20555. 17.5.18.Rl The Energy People

I 1un"t. ru'-'-V 1"""1.,,.,"".'""'"'*............ *- ** - DISOIARGli MO:-llT.Q~IHG REPORT r T*<0 App1*vc;t 0.'"' ~"* ISS*R:01J PUBLIC SERVICE ELEC l GAS SALE l GP lT 2 Hl I 80 PARK PLACE NEWARK I

  • t I **-*.

tu 07101...... 0005622 "f rfJ tfil 1-~---.. ~c~~-M-,,~h-U-~-*w-C~A~----~ lllP'iU\\TING P[lll001 lll014 i I lll*J"Jt !I PA;'l&WITlr. C:JllOJ 1 -~J~. 5-DAV, IO&.,OIOfCD 20 C'EG. c. . EffLU~rtT CROSS. CCNDIYIOtf I :c~~::. :J') l

I sri!.1;)$, TuUL

""':.-~Ri'IC.D

S!.J!;H;
~::O

. f Pl:*na&T

t:rFLt:::;-.;r G~CSS CC.ND11T10,.

rrm, l' I. FLO.\\Tl~G SOLJDS AS:*Oll'lli.O I PC141Aill ' HrLU::NT GROSS CGrt;M TIC.IC .-~tc;r~1 ~ fl[,\\,; .. l.ll'OATCD Pll.,... &1' I EF E~IT-GROSS CONOIYIOM v l I CfiLJFCi\\:-t-FECAL lll"'Olll&D EffLUff\\T CROSS CON:l11f10M l

  • IO&PQIOYCO PIS'.R\\.tl'f I

CONi;lfloi>>N I llC*Ollf&D COttOIYIOtt \\ P.IPOIOYIEO ~&:.ftt.llT * ~0.. 01TICN ....., Qfl pa,,.(;1P&L l:lllCUTIVI Or,1oetR Schneider, F.W. L&:_,- F1AJ.T DELAWAlle RIVER LOWER ALLOWAYS.CREEK** INSTRUCTIONS J

1. l'rovhlc 411H tor r*tl** nvetd bJ 1!al* *O?*rt 111 &:iiHU a1di14 Rt:J'o~n::a Pt:r.:on**,
2. E:nto1r fCl'OrtCI.. 1n1... u..,...... r.. _,., -**l*o:* '!*I,;.::"""~* "Qt:A~"TlTV"u..:**co:;c~:tr..\\':'IO:.-

ln lh* unlH J;n*.clfi... f*i' **di l'*r~olc* n "'rrc.;1d*I._ D* ir:-.a c:iacr..... :un aa lo.Jin c=.. :..011;1:a LATITUDE LONGITUDll H*IJI ll**HI l)Q* II TO 7 YE41l uo I DAY Yl!All Nol DAY (J **hi !"'rJ QUANTIT't II'**"' lll'11lll.IN AVlllAG& l(AlllMUN l.IHITI 0.022 0.046 .062 KG/DAY .. * *.. * * * * * '°' 0.026 .057 .075 KG/DAY

  • Ill * * * * * * * *
  • 0 Q

0 VIS 0 0 O** -4 6.0XlO.. 7.4xio_4. 9.8xlo.,3.. KGD

  • *** * * * * * *
  • 0.*.

>) * * * * * *

  • N/lOOHL I.

TITLS 0, THE o'"cc" OATI 'V.I?. Production 7f3 14 ~ 11 TITLI: YC411 uo OAY aatcrh:n. ,\\ VIUCAGR la.wcui;e ClllJ-&olrd *YCI.i.:tu~I '.Al 4u~u;:* la Ojilcrall:.G> **:U.ll!l.1.1'1 ._,,, "J.llt\\ILIUW' ***.Hh*""' w*luca eburv~.a d~rl":i lb* N;H'rdn& ;1e1i">°i. Sp1*cll~ "'" *.,.,.l..:r ol an~IJR.. cl *~**rin lh.i "'*n1:d iii* c:;.1<l.a111r. (:.ri.r.1111:1i1da.ci u **1;1:,.;.riel*J 11c*et.ll.:en1l*1;c.s1* la the c;olvntn* la.*:c!ud **:fo. :tic. U r...a*"""* lir.U* **Q". .._ E,ucllr l*c*:u**n'r of...... 1,11e,.,,.,.,,., p111on.. :I*** u ='o. u;.IJ&.. 1/~11. Lr.. f*I** "J1r'" I* *c-~...

  • 10:111 In,J *11:.lr***~ p~r/.,,..,..,, fl*'U/f 1 11.;r11.J If O:JalJ:iul\\11&.,n1.-r "'CO:!IT. **

I. S;>e1:Ui *-1*lo lypa f "~r;dl' *r "- 111. cu:,...,**ll*"J at 19,.llcablC'. II f1e:;uocr *** c.11t:o:11e11._ ~nlc* **t:A11, G. Jlp1uopt111111 Pl1<11ol11rci h rrr111ht*l.,,. L3llor" *f l\\11 fon:i.

  • f R *i.;11111 oibon acl rct"IA r&*"'~ lor r.i:u rccorC:n.

~

    • Fold.alon~ dolled lln~a. 11~~1~ ar.4 1111oll Orlcusal I* etllu *~c.c~n.,* la p*:::-JL H&*t**

,,..........,) cor.;:::INTAATION ,j r11u;1:*cv.

  • l*L'........

l.. *Cll IU*UI I........., NO, MllUMUM AVlllAGI* NAll1MllN Uh1:& .. a. o' I TYl'Z IX IX A.. 4L'rJl1 ~l**l/7 I 8

16. 5.

22 GR I f'G/L I I 0

30.
45.

! !/30 c~ 9.2 20.4 I GR 26.9 I J L'.1 I ~G/l I ~ I Cl *

  • Cl 30 *

'*5* I ! 1/30 I ~4* I 5/7 N/A

  • *
  • ti EXCP I *$

...,;. 4' *

  • 111 * *
  • Cl *
  • 31/31 l 31 Day comn*.

HGD

  • * * * *.* ~**

~ *

  • I

<2 9.8 33 1/7 GR 4!0m* ** I i i 200. 400.. 1/30. G:l. I . i I I

  • 1 I

I I* I I I / ~f:/1~/d/ I ce11llr IA*I I *m,_,,,,,, Mlllh th lnlo11n.,rlon coi:,,.l11ed lt1 r.'11.. ,.,..,, *nd lb.;I I* *fl* li.>*1 *I 01r Ar.e r.*fcd,:* and h:lel euo:A lr.t..r / j./ .,arlt" II INC. uu.plclo. end *ccu1alet. .l:CotAT;,7'1: 41 l'll-fo;l>A-.:ll:CJf;\\IC o'" w11 a..1-:... :.,..*:c2 *-:;.:.. r I ~- I,,,,* *I ..... :::.7' O'

  • I r I I I

I I i . \\ ; I I I i I I I I I

NATIONAL. POLLUTANT DISCHARGE ELIMINATION SYSTEM DISQtARGE MP'~"fORING REPORT F'*"'TJI App1ovod J NO. J5il-R0073 PUBLIC SERVICE ELEC ' GAS SALE 1 DELAWARE RIVER GP AT HI 17 2 I 80 PARK PLACE NEWARK NJ 07101 L IJ-&J ~ 0005622 I T Pf:AMIT NUMBER llEPORTllHi Pll!:RIOD: fROM IU*Ji71 PARAMETER 00010 2 TEMPERATURE,WATER R&POAT~D DEG.CENTIGRADE PKH.MIT INFLUENT CONDITION -00010 1 TEMPERATURE,WATER ftliPOftTKD DEG.CENTIGRADE PliltMIT EFFLUENT GROSS 1;0NDITION -*00016 4 TEMPERATURE HtLPORTKD DIFFERENCE Pli:.RMIT EFFLUENT NET CO~OITION

  • -oi:i""4-i:io 1

ftEPORTIEO Pll Pflt.RMIT EFFLUENT GROSS CONDITION 190050 l LOW R&:PORTli.D Pl!.RMIT EFFLUENT GROSS CONDITION ftll:POHTltD PEflMIT CONDITION 'fU~PQftTED Pi:ttMIT CONDITION Hl::'.'.POHTlt'D Pi::ft._.IT CONDI Tl OH NAM( OF PRINCIPAL EXECUTIVE OFFICER Schneider, F.W. t--* LAST FIRST Ml J &U*llU LOWER ALLOWAYS CREEK COOLING WATER INSTRUCTIONS I. Provide doto* for period covered by lhlo report In *pacoo marked "REPORTING PERIOD". 1 4 ~a 1 .I

  • 14931 I

&IC LATITUDE LONGITUDd

a. l!:nler reported minimum, avarow:e and medmum valuca under "QUANTITY" ond"CONCENTRATION" In Iha unit* apecUlod (or each parameter H approprloto. Do not enter value. In boxoo conlalnln11 a&terlokM. "AVERAGE" lo avera110 computed over octuol Um* dloch*r11* lo oporaUn"- t.IAXIMUI&"

and "MINIMUM" ara oxlremo v4'lue* obuerved durine: the reporUne: period. 3, Spoclly tho Aumbcr o( analyud Hmplea lh*I exce"d Iha maximum (ond/oronlnlmum ** opproprlol*) permit condltiona In tbe column* labefod "No. Ex. II nonct, enter 110".

4. Specl(y frequency o( analy*I* (or each porameicr H No. analyaao/No. dayo. (*.fl., "J/1" I* aqulv.o-lent to J ounlyao& poclom1ed evory 7 duya.) U conllnuou11 enter "CONT."

no-au u.1-231 1... am lll*ill 121*.HI IJO*I I S. SpecUy 1u1.mplo type ("IJtab" o~ "-hi'. compo1til1o"J aa 6tpplicoble. If frequency wae conUnuoua, 8 0 3 0 1 YEAR MO DAV en1ur "NA 11*

6. Approprl*I,. *l1:11atura I* required on bottom o( lhl* (orm.
7. Rcmovd carbon and relaln copJ for your rccorda.
8. Fold alon11 douod line* &loplo and moll Orlaln*I to omco *pcclflod In pcrmlL TO 7

0 3 3 11 VEAR MO DAY 11'4*111 1oe-101 (J card only) QUANTITY (4 cord onl,) CONCENTRATION fREQIJENCY IH-.. llt ,... *Dtl

      • +-IU IG1*1J IH*4DI l*O*OJI 114*10 tU*U SAMPLE NO.

01' NO. TYPE MINIMUM AVl!RAGli: MAlllMUM UNITS l!X MINIMUM AVEltAGll: MAXIMUM UHITI e:x ANALYSIS 0.6 1.9 4.4 CONT~ N/A DEG.C DEG.C t:ONT 0.3 9.0 17.8 CONT. N/A DEG.C DEG.C 46.00 C:ONT 0.8 7.1 15.1 CONT. N/A DEG c 15.30 6.7 7.0 7.4 2/7 GR SU 6.00 9.00 U1 GR 0 231.4 532.8 CALC. N/A HGD MGD f':ONT CONDENSI R DISCHAR GE Tt1"~-:.~,T MOIDRI ~ DEVICE n IDICATES HIGHER r ~HAN AC'IUA w CONDENSI R DISCH \\RG 8 TEMPERl TURES. DESIGN C HANGE IN :)ROGRESS,, 0 RF.TlY' \\TE DISCHARC E '.I'HERMAL MONITORTh r, DEVICE 7..NII Cl""' 'l 'I PROBLEM / / TITLI! OF THE Ofl'ICER DATE '>I t-llo /If{. 7.1alo 14j111 I Cdrllty Uou/ I *m /11111lllar wllh lho lnformarlon conl11lnod In lhl* / V.P. - Production rupotl *nd lh*I lo Ito* l>ul ot my li.nowtodJJ,o ond l>ullu( auch lnfor-61GNATURf:pl' PRIH-CIPAL EXECUTIVE 01tatlon I* lruo. complolo, *nd Mccurilll~ TITLE VEAR MO DAY OPflCER OR AUTHORIZED AGENT ff"A foomm0-1(10*7l)OIS 401 IS CONDENSER COOLING WATER.WHEN INTK PH LESS THAN 6.0,DIS PH -R TllAN 9.0,DIS PH NOT TO HCO INTK NOT TO SE LESS. WHEN INTK "PH GREATEPAGE ORIGIHAL OF ~!

  • I

' I.; I~

HATION"L POLLUTANT DISCHARGE ELIMIUATION SYSTEM DISCHARGE Mn~ITORING REPORT F~rm.~pprovod / El NO. l58*RD013 r PUULJC SERVICE ELEC & GAS SALE l DELA~ARE RIVER GP AT Ml LOWEil ALLnlAYS CREEK 17 2 I 80 PARK PLACE COOLING WATER NEW.ARK INSTRUCTIONS NJ 01101 *

1. Provldo dalca for period covorod by Utl* reporl In apace a marked "REPORTING PERIOD".

L J

2. Enler reported minimum, averoao and mulmum valuca under "QUANTITY" and "CONCENTRATION" U*!.I

. CIJ*UU lo lho unlla *pocltled for each puromoler au opproprlolc. Do nol cnler valuea In boxea conlaini1111 [itl ~ I I I aaleri&ka. "AVERAGE" la overo11c compuled over aclual Ume dhchor'e h operalln" "MAXIMUM" -~ and "MINIMUM" cue exlremu voluoa observed durlnjl lho reporUng period. 00056?.2 I

3. Specify lhe number o( analyud oamploa lhal excoud the maximum (and/or minimum** opproprl*I*)

PERMIT NUMBER SIC LATITUDE LONGITUDll permit condition* Jn the column11 labeled "No. Ex." 11 none, enter "0* T ... Specify (requency of anolv1io (or each purameter.,. No. anolyua/No. dave. (o.Q., "J/7" I* oqulva* s I ?O*all UZ*ISJ U4*1al fH*J.71 tH*21U l~*IU

5.

lunl lo J analyaaa porfom1od ovory 7 day a.) If contlnuou1 enter "CONT." Spocllv 1omplo lypD (Qrab" '" "-ht. composllo") H oppllcablo. II froquenq waa conUouou*, t7 18 013 011 f7 18 op 311 enter "NA". Rl>PORTING Pl!RIOD: fROM TO

6. Approprialo algn1luro la required on bottom o( lhh form.

VEAR MO DAV VEAR MO DAY

7. Removo carbon and reloln copy lor your recorda.
8. Fold alon11: dolled llnea, ateplo and mall Orl11:ln1I lo olfico 1peclflod In p*rmlL IU*11'1J 11'4*011 IGi*JOI (J coril onlrJ QUANTITY (4..,d onlr)

CONCENTRATION fREQUENCV PARAMETl!:R Ul**a1 141**8l lail*ll U**40I l~*llll UU*lll IU*Cll SAMPLE .NO. Of MINIMUM AVERAGE MAXIMUM UNITli MINIMUM AVERAGE MAXIMUM UNITS NO. TYPE EX EX ANALYSIS CCOlO 2 TE~PERATURE 1 WATER RILPORTED 0.6 4.4 1.8 CONT. N/A DEG.CEl\\TIGRAOE PIUtMIT DEG.C DEG.C INFLU(NT CONDITION CONT coc10 l T~rPERATURE,WATER flEPOftTCD 0.3 8.4 16.7 CONT

  • N/A r:EG.CE/\\'TIGRADE PERMIT OEG.G OEG.C HfLUENT GROSS CONDITION 46.00 CONT

-CC016 Ii 0.6 6.6 13.-4 CONT. N/A TH'PEP.ATURE ftl!~ORTllD DIFFEREl'iCE PERMIT DEG c EHUJFNT NET C0t4DITIOH 4 15.30 '. Cd4Cll 1 Ptl RC.PORTED 6.7 7.0 7.4 2/7 GR P~RMl1' SU EFFLUErn Gf{OSS C:OtHllTION 6.00 * ** * * <J.00 217 GR -5tC:lO 1 0 231.4 FLC11 REPORT KO 532.8 CALC. N/A PERMIT MGO MGO EFFLUENT GROSS COHOITIOH CONT "£POHTILD CONDENSE! DISCHARG S THERMAL MJNI'IDR ~ DEVICE NDICATES PEftMIT CONDITION HIGHER Tl tAN ACTUAL CONDENSE! DISCHA RGE TEMPERN !ORES. rt;IEPOftTILD DESIGN CI (ANGE IN p ROGRESS T< REL~ rES DISCHAR( E 'I PERMIT CONDITION THERMAL~ ONI'IDR.:[N; DEVICE Al' ID CORREJ CT PROBLEM. REPORTllO PIEHMIT CONDITION I N~ME OF PRINCIPAL EXECUTIVE OFFICER TITLI! 01' Tiii! Ol'FICER DATE 1Jtl fl. ~ 7 18 lo 141111 I corllfy lhal I 41m (omlllar w1U1 Iha lnlonnallon conla/ndd In lhla (\\,;

./;'/~.**

/ Schneider, F.W. V.P. - Production report and I/cal lo lh* boat of my lmowlodQo and b<Jllo/ auch In/or-SIGNATUruf Of PRINCIPAL EXECUTIVE malJ011 I* 4ruo, complolo, *nd accurat.. LAST FIRST Ml TITLE VEAR MO DAV OFFICER OR AUTHORIZED AGENT f PA form, lll0-1 (10*1ll 0 IS 4 0 2 I SCOITT:l E f\\ S ER COOLING WATER.WHEN INTK PH LESS THAN 6.0,0IS Pli NOT TO BE LESS. WllEN INTK PH GREATIPAGE OF . R *THAN 9.0,[)lS PH NOT TO EHD INTK ORIGINAL I' I ' ~... ~: it 1 7 t:; IQ

II NA UUNAI-l"Ul-1-U I ANT Ull>l:HAHGC: C:LIMlt<ATION SYSTEM f"onn App1ovod j DISCHARGE pn~ITORIHG REPORT .IB NO. J58-R007J r PUBLIC SERVICE ELEC £ GAS SALE 60 PARK PLACE NEWARK NJ 07101 L U-$1 CU*1tU ~ 0005622 ~ i't93 l I T PUtMIT NUMBER DIS lilC LATtTUDI! LONGITUDI! UO*IU REPORTING PIUUOD: l'ROM TO 7 8 0 ;3 3 VEAR MO DAV I Jl*:Sll (J ca1d onlyj QUANTITY PARAMETER U&*41H t.al-13.I MINIMUM AVl!RAGt: ldAICIMUM UNITI -CCOlO 2 0.2 1.6 7.9 lf.l'PtRATURE,WATER R&PORT&D Df.G.CENllGRADE DEG.C PERMIT HIFLUEtH CONDITION --c (c i o i R~POftTED TE~PERATURE,WATER

1. 7 8.4 16.7 c EG. c rnr I GltADE OEG.C PERMIT EFFLUENT GHOSS COHDITIOli * * *
  • 46.00

---CC:o l 6 4 14~1 TEl'PERATURE ltU:POftT~P 1.1 6.7 CIFFERENCE PERMIT DEG c EFFLUENT NET CONDITION 15.30 (0400 l 6.7 7.0 7.4 PH RliPDflTt:D PRRMIT SU EFFLUENT GROSS CONDITION 6.00 * * *

  • 9.00

-,'0050 1 0 238.l 532.8 LCW A£PORTIE.D PERMIT MGD EFFLUENT GROSS ~OH DI Tl ON ftliPOtilT£D PE.AMIT CONDITION ftllPOHTM.D P~RMIT CONDITION ftEPORT&D P~RMIT CONDITION NAME Of PRlllCIPAL EXECUTIVE Ol'FICEH TITLI! 01' THI< OFFICER DATE 11 sl 011 ~ 11 ~chneider i F. W. V.P. - Production AST FIRST Ml TITLE VEAR MO DAY 1 DELAWARE RIVEll GP AT Ml 17 2 I J LO~ER ALLCWAYS CREEK COOLING WATEI\\ INSTRUCTIONS

1. Provide d*IH for porlod covorad by lhla r<'P<>rt In upach ma1ked "REPORTING PERIOD".
2. Enlor reported minimum, evorago and maximwn valueu undor "QUANTITY" and"CONCENTRATION" In 1ho unll* specified for *&ch par<un*ter u opproprlalo. Do not enler valuu In box... contalnln1 auteri&kL "AVERAGE la averai:a computed over actual Umo dloch**i* la opcraUn1o MAXIMUM" and "MINIMULI" arc extreme voluos.ob&erved durlnc lho reporting period.
3. Specify Iha number of analyzed oampl<1u that oxceed lho maximum (ond/or minimum H appropr/alo) pennJt condition* in the columna labeled "No. Ea.** U none, enter 110".
4. Specify frequency of onelyala for each (l*r*melcr aa No. analyooa/No. daya. f**1'** "J/7" I* oqulvA-lonl lo J analy*c>a potlormod av.. ry 7 day11.) U contlnuoua enl*t "CONT."
5. Specify umplo type ("iJrab" or "-hr. f;OmpoMllo") **..,pllcoble. IC froqueocy waa coaUnuoua, enter "NA".
6. A1>propriata &ljplatur* la required on bollom of lhl* form.
7. Remov* carbon end retain copy for your rocorda.
8. Fold *lon1 dolled lion, &topla and mall Oril[lnal to olClce 1pec1Cied In pcrmlL (G.f*OCU 19-101 (4 cotd only)

CONCENTRATION l'REQUENCV IGl*Qli I 11*4DI (41*111 U4*11, tU-Cll 01' IAMPLE NO. NO. TYPE l!:lC MINIMUM AVERAGE MAXIMUM UNITI EX ANALV51S CONT.* N/A DEG.C CONT Ji< * * *

  • ~ * * * * *
  • CONT.

N/A DEG.C CONT CONT. N/A 2/7 GR 211 GR CAIC. N/A MGD CONT CONDENSE R DISCHARC ~E 'l'H~~"~ T MONI'IOI ITN( ~ DEVICE INDICATE S HIGHER r ~HAN ACTUA w CONDEl SEJ ~ Disrm:i.~ ~E TEMPERA'l tJRES. DE~ bIGN CHANG ~ IN PRC IGRJ ~SS 'IO RE (.OCATE DISCHARG ~ THER.\\1AL MONI'IORIN 3 DE.VIC1 Al ro CO.t<l'<.tl...11* PROBLEM. / i I ca1lily' lhal l am lamlllH with th8 ln/onnallon conllllnod In lhl* _,;/)</t J l l\\. , :,-:i I /'J - / rdporl and lh*I lo th* boal o/ PIJ' knowlodilo and bollol Much In/or-SIGNATUREfF PRINCIPAL EXECUTIVE tnallon I* liuo. complalo. *nd acc"r.alo. Ol'flCEfl OR AUTHORIZED AGENT iu F.... u2o.i110-n1D IS llO:i l!> CuNUU-.SElt CUUL ING WAHR.WHEN INl K PH LESS THAN 6.0,DIS PH NOT TO BE LESS. WHEN INTK PH GREATEPAGE 01'

  • R THAN 9.0,0IS PH NOT TO EXCD INTK 17.5.18 I**

I 1 ** ; ~ ORIGINAL

. I I* NATIONAL. POL.L.UTANT DISCHARGE EL.IMIHATION SYSTEM DISCHARGE; '"'HITORIHG REPORT Fo1111 App1ovad* ,UB NO. J5a-R007 r PUOLIC SERVICE ELEC & GAS SALE l OELAHARE n1vrn GP AT Ml 17 2 I 00 PARK PLACE NEWARK NJ 07101" L IJ.*>> '4*1tJ llJ*Ht ~ 0005622 ~

  • 1~9311 T

PERMIT NUMllER GIC s LATITUDI! LONGITUDI! 120-111 UJ-a11 14*1DJ Rl!POllTlllG PERIOD: l'ROM 8 0 3 0 1 TO 8 0 3 3 1 YEAR MO DAY" YEAA MO DAY 11ii*t1I (J c.ard only) QUANTITY PAl\\AMl!TER fH**"I '""**31 .u... 01* MINIMUM AV.:.R.t.GI! M.t.l<IMUM UNITI CCOlO 2 TE~PE~ATURErWATER RILPOATli:D CEG.CFNTIGRADE P~RMIT OEG.C INFLUEIH CON Pl Tl ON l:.CJ l G l iE~PERATURE,WATER RE..-ORTILD DEG.CENTIGRADE P£HMIT DEG.C f:FFLUFNT GROSS co1.. 01T10N 46.CO -teen, 4 T E"PEHATUilE R!i.PORTEO CIFFEKENCE PERMIT OEG c EFf LIJENT NET COtlDITION 15.30 -c:-oi.oo l Pll Rli.PORTE.D Pt:RMIT SU EfFLUi::NT <;ROSS COUOITION 6.00 * * *

  • 9o00 5C050 l

fl Ow R~POHTi:D PILAMIY MGD EFFLUENT GROSS COHDITIOH ljc >I;: *

jc RK.PORT~D Pi'.AMI T CONDITION fU£PORTILD NO DISC IARGE,-y._"I 'I

~.!"'H I DURTI 1G THIS Pt:HMIT CONDITION Rl!:PORTll:D PEftMIT CONO&TION

  • -~

!<AME OF PRlllCIPAL l!><ECUl'IVE OFFICl::R TITLE OF THE OfFICER DATE Schneider,F.W. V.P. - Production 7 I a 1 0 I 4111 1 LAST FIRST Ml TITLE VE:AA 140 DAY J LOWER ALLOWAYS CkEEK COOLING WAHR "a*H NO. EX REE INSTRUCTIONS

l. Provide doleo for period covarod by lhla report In opacco mail<ed "REPORTING PERIOD".
2. Enler reported minimum. avar*i:e lllld maximum values under "QUANTITY" and"CONCENTRATION" In aho unll* specified for i1u1ch poromeler "* upp1op1lala. Do riol enter valuca In boxem conlainin1 11a1erhkL "AVERAGE" la average computed over octual lime dioch*r&* lo opcraUna;. "t.IAXlMUld" 1111d "MINIMUt.I" ""' nlremo value a observed during lhn reporting period.
3. Specify tho number of analyHd oamplao that exceed th* maximum (and/or min/mum ** approprlalo) pcamll cond,tlon* In lho column a labeled.. No. Ea.** If none,. enter 110" *
4. Specify frequency of 9R&lyrJa for each p*r*melcr MO No. analyHo/No. d*JD. (*.s.. "3/7" I* oquh**

lenl lo 3 linalyaoa por/onncd ovary 7 day a.) If conUnuouo en I er "CONT." S. SpocUr aamplo lypa ("Srab or "-hr. composllo") ** appllcoblo. If frequency Wa& contlnuoue, cnler NA*

6. Appropriate algn*luro la required on bollom of lhl* form.
7. Remove carbon and retain copr for your recorda.

8 Fold al doll d II &I le and moll Orl11I I I fClco a c *l(j d I permit. on11 8

ncti, ap na 0 0 p

~ e n U.f*OIJ lt9*701 (4.. rd only) CONCENTRATION FREQUENCY I H**Dt 1*1-1ua 115*** IJ ~H*Ol IAMPLE Of MINIMUM AVt:RAGI! MAl<IMUN 110. TYPI! UNITI l!X ANALYSI& OEG.C CONT DEG.C CONT >C: * "' l(c 2/7 GR HGO + "' *

  • CONT ORTING PE ORD.

I cMll{y lhal I om laml//ar WIU1 tho /nlomiatlon conlalnod In lhl*

JrJ_ 'J /

e--/r

u,. -

f..-.~- roporl and l/1al lo lh* bul ol my lmowlodao ond bollol 11uch /n(or-J. 1unlJon j., liu..,,. comploto# *nd *ccur~t.. SIGNATUHE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT

  • f-;~ f~*m mo-1 ( 10*7:1) DJS 4 0 4 IS CON DEN >r:K c;ouL lNu WATER.WHEN lNTK PU LE-SS HlAN 6.0,DIS PH NOT TO BE LESS. WHEN INTK PH GREAT&AGE 0 f R

THAN 9.0rOIS PH NOT TO EXCD INTK 1 7 i:; -1 R I** I I. ORIGIHAL

] NATIOflAL. POL.LUTAUT OISCHARGE ELIMINATION SYSTEM DISatARGE *' *11TORIHG REPORT I ~!~rm Approvod IB NO. J58-R007J r PUBLIC SERVICE ELEC & GAS SALE 1 DELAWARE RIVER GP AT Ml 17 2 I BO PAHK PLACE NEWARK NJ 01101* L ~ c..., ** 0005622 PERMIT HUMBER REPORTING PERIOD; !'ROI.I IU*UI f'AllAMETf:ll -cc-010 2 TE~PERATUHE 1 WATER Hl:PORTllO C[G.CEtH I GRADE PliRMIT lfJF LUEt~T CONDITION _c_f.C_l o 1 ftE:PO"TliD TE~PERATURE,WATER CEG.CENTIGRADE PERMIT EFFl.Ul:NT GROSS CONDITION C0016 4 TE1PERATURE RE.PORTltO CIFFE~ENCE PE:AtAIT EFFLUENT NET CONDITION C0400 1 Pit ft~PORTltD Pi':ftMIY EFFLUCNT GRCSS CONDITION 5CG50 1 FU:1~ REPORTED PENMIT EFFLUENT GROSS COHl:>ITION A&;:POATILD PERMIT CONDITION REPORTP:D PICRMIT CONDITION ftliPORTlli:D P£RMIT CONDITION tlAMIO OF PlllNC:IPAL EKEC:UTIVI! Ol'f'ICER Schneider, F.W. LAST FIRU Ml LOWER ALLO~AYS CREEK COOLING WATEI~ INSTRUCTIONS J I. ProvlJo dale* for pcrloJ covered by lhl~ report In apach mutkcd "REPORTING PERIOD".

2. Enlor reported minimum, avorag* AAd muhnwn values under "QUANTITY" and "CONCENTRATION" ln tho unit& 11pocHied (or 011ich parOJQctur 111 epproprlate. Do not enter value* lo boxes conlainlna:

uturisk&. "AVERAGE" h avera11c computed over actual Umo diochurco h operaUn&;. "MAXIMUM" and "MINIMUM" are extrema valuoa observed durln11 lho reporlln11 poriod. . LATITUDE LONGITUDE tU-UI lal.. JfU UO-Dll TO YIEAR,.o DAY YEAR MO OAY ( J c*rd enl,*) QUAN Tl TV (Jl*Allll

  • .fe*lll

. MINIMUM AVERAGll MAXIMUM UNtTI DEG.C DEG.C 'i6.00 DEG c 15.30 SU 6.00 9.CO MGO NO DISC -JAR.GE OC1 11*,C.!../H t DURI ~G THIS TITLE 01' THE Ol'flCER DATt: V.P. - Production 78 14 h 11 TITLE YEAll MO DAY Jll*al NO. llX REl

3. Specify lho number of analyzed oampleo U.at exccud tho maximum (and/or minimum H
  • pproprloto) pennlt condiUonu In U10 columns lsbelad **No. £11:.** 11 none, enter "0".
4. S1>cclfy frequency of anolysla for each parameter ao No. analyseu/No. day&. (o.Q., "J/7" I* oqulva-lcnl lo J ona/yaa,. porlom1dd ovory 7 duyo.) If contlnuoua enlcr "CONT."

S. SpocU11 &amplo typo ("l)rab or,._hr. compo#llo11) as applicable. If frequency wa11 conliououa, enter "NA0.

6..Appropriato olgnaturo lo required on bottom of U.lo form.
7. Remove carbon and retain copy for your record*.
8. Fold alonii dolled llnea, 1taplu and mall Orli:lnal lo offlco apecific.d In pormiL l*4*111
    • ~-70)

( 4 ca1d only) CONCENTRATION fREQUENC:Y ,,.... uu I.CO*O:,, llS4*G II IOJ*Gl SAMPLE Of MINIMU.. MAXIMUM NO. TYPE AVli:RAGll: UNITS li:X ANALYSIS DEG.C CONT DEG.C

)<

CCNT 217 Gtt MGD CONT IQRTING PE RIOD. / I >:IJ '& /: \\ /') I C<>rllly th4'1 l 1un laml111u with U1* lnlomiallo11 contained In U1I* -..../. -/ ~/,,.,./ roporl and lhol lo lh<> but of my lmowlod.fl* and b<>llol auch In/or-illiNATU~t:OF PRINCIPAL EKEC:UTIVE 1111.t,on '" two, complolo, and *ccuralo. OFFIC:E Oft AUTl<OlllZEO AGEHT 'EP"A f**ramo-1110.7 UIS 4U!:> 15 CUNUENSttt COOLING l) WATEI(. WHEN !NTK PH LESS THAN 6.0,DIS PH NOT TO DE LESS. WHEN INTI< PH GREATEPAGE OF R lHAN 9.0,DIS PH NOT TO EXCD INTK ORIGINAL

.J l J NATIONAL POLLUTANT O!~CHARGE ELIMINATION SYSTEM .DISCHARGE.. JTORIHG REPORT .rm Approvod .48 NO. l5&*R0073 r PUBLIC SERVICE ELEC & GAS SALE 1 DELAWARE RIVER GP AT Kl 17 2 I 80 PARK PLACE NEWARK NJ 07101

  • L U:*:U 14* IG'

~ OGP.5622 PERMIT NUMQER Ht:PORTING Pt:HIOO: FROM I 11*171 l"AftAMETe:ft re-corn~ TEPPERATURE,WATEP Hi:PORT.£0 VEG.CENTIGRADE PERMIT lf"lFl.UEf\\T CONDITION

  • c~to 1 T *f"PER/ITURE,~IATER ftltPOftTl:D Dt:G.Ci:l'lTlGRADE Pll[RMIT EFF LIJEfliT GHIJSS CONDITION COCl6 4

TEMPEHATURE fUi.POHT~O CJFFEHENCt: Pli:fUdlT EFFLUEt\\T NET CONDITION --co4oo 1 Plf HKPORTED PERMIT EFF LIJEl\\T GROSS CONOITIOti ~CO~u l FLCW ~l[PORTli.D PllERMIT EFFLUENT GROSS COHOITION tU:POHTll.D PERMIT CONDITION HliflORTltD PERMIT C:OUDITIOti REPORTED PERMIT CONDITION H~ME OF PIUllCIPAL E)(ECUTIVE OFFICER Schneiderl F.W. LA~T. FIRST Ml LOWER ALLOWAYS CREEK COOLING ~IATER INSTRUCTIONS J

l. Provide date& for period covered by tbl* report In spuceo marked "REPORTING PERIOD".
2. En tor reported minimum, "verago end maximum valuu undor "QUANTITY" and "CONCENTRATION" In the unllB apecilled for ""ch porlllllcler ao opproprlate. Do not onler valu.. In boxu conlainln1 asterlskL "AVERAGE" I. uvera11:* computed over actual limo dlechargo b operalinK- "MAlUldUM

117* liJ ~ Ii 14931 I SIC LATITUDE LONGITUDE uo-a u ca.-.-111 U4*:UU 7 8 0 1 TO Yt:Aft MO DAY (J ***d only) QUANTITY

  • Ul**HI IU*aJI MINIMUM AVERAGE MAKIMUM UNIT$

OEG.C DEG.C 46.00 DEG c 15.30 SU 6.00 * * *

  • 9.00 MGD NO DISC BARGE CC1 l""~tt;11 DURJ NG THIS TITLE 01' THE OFFICER DATE
v. P.- Production
  • 71slo14l111 TITLE:

YEAH MO DAV MJ*h NO. EK RE and "MINIMUM" are oxtremo valuoa observed durln11: lhc rcportinii period

l. Speclfr the number of analyzed HP1plca thol "xcced thu maximum (orod/or minimum a* *pproprl*I*)

permit condltlona 111 lho columns labeled,.No. Ex.." If none, en1e1 "0.

4. lipuclfy frequency of analyal* for aech p*ramulcr am No. analy***/No. day*. (o.J1., "J/7" la equiv**

lenl lo J a11aly.,a* par/ormud ovory 7 day*.) U continuoua enter "O)NT." S. Spc:cUv aa.mplo type. {"ll.cllb or,._ l*r. compoaHe,.) 11u 11Ppllc11blo. U frequency waa conUnuou*. enli!'r "NA".

6. AppropriMlo 11lgnaturo l* required on bottom of lhh form.
7. Remove carbon ond retain copy for your record&.

8 Fold alonii dolled Unoo *toplo and mall Original to office opccl{led In permlL l1U 0 ae1 C*D*70J ( 4 card only) CONCENTRATIOll FftEQU!::NCY IH*.tEIJ 141*D31 u...... IOZ*Gl liAMPLE Of UNITli NO, TYPE MINIMUM AVt:RAGE MAKIMUM EK AHALY515

  • * >k * * * * * * * "'
  • DEG.C CONT DEG.C CONT 211 GR MGD CONT
JQRTIN3 PI ITTIOD.

I / I corllly lhol I *m lamlll*r with lho lnlo11ntlllon contalnocl In lhl* ,;ry;;' /./ -:~ J l 11:?-- ~*. ( (..

  • ,; _,,,....__,,../

roporl..id lhal 10 lh41 be.I of my knowlodiJe and bollol *uch In/or-rnatlon la Imo, complol*, 1md *ccutiata.. ilGHATURE OF PRINCIPAL t:KECUTIVE OfFICER OR AUTHORIZED AGEHT ,*EPAF ** nimo-1110.121015 1106 JS CONDENSER COOLING WATER.WHEN INTK PH LESS THAN 6.0,0IS PH NOT TO BE LESS. WHEN INTK PH GREATCPAGE oF R lllAN 9.0,0IS PH NCT TO EXCC: INTK ORIGIHAL

17. 5. 18

~** ' 1.,;.*

\\....__/ r PUBLIC SERVICE ELEC ' GAS SALE L C1 [ttj BO PARK PLACE NEWARK NJ 07101 l... \\GI 1---~o_o~ Q s 6 2 2 F PERMIT tlUMOER REPORTING PERICO: FROM Te lSl*nl PARAMETER 00017 4 ft&?ORTEO HEAT HILL IONS OF IHU 1 S PER ~HR PERMl'l" EFFLUENT NET CONDITlON -scfcEro l FLOW RCPO RT ED Pl~AMIT EFFLUENT GROSS CONDITION Rl!PORTEO PERMIT GON DI TIOP'~ fit:PORTC::O Pl::HMI T I CONDITION e H t:.PORTi!.D P~AMIT COllDITION R&::PUH.TEO PEHMIT CONDITION ru::PORTE.0 PEAIAIT CONDITION REPORTE:U PEro.11T CONOI TION D ~ ( J ca1d only) (38*"" MINIMUM 0 0 NA'flONAL POLl.lJTANi 01sr.1u,1i.GC E.Llt.11rJ"flON ~i'!;"fLM DISCHARGE M ORIHG REPORT Af>{*to~*ct/ , NO. JSiJ.JW073 l DELAWARE RIVER GP AT HI l7 2 I J LOWER ALLOWAYS CREEK COOLING WATER

1.
2.
3.

INSTRUCTIONS Pro\\l'idc doles for p~rlod covered Ly lhla n1>torl ln t;pncea nu.irked REPOHllNG PEH.IOD". Enter reported minimum, avon.q::c nnd mnxi1nu11\\ vnJucs under QUANTlTY" und 1'CONCENTl'iATION 11 in lhu unit& &peciCicd Car e.ich purnmcler 11!) llpprvpriute. Do nol enter vtilul:& in Loxes <:ont1.ining 11:;.tcri:.:kn. "AVERAGE" is u.vcro(!c computed over nctual time d.ischoq:e 1!1 operolinc.- ' 1UAXV.lUM" nnd "MINlMlJt-.1" hrc C>\\lr~mt: vo1ha.-s obsorvcJ dudnt~ lh c rct>ort.iog period. LATITUDE LOtlGITLIOE SpccHy th~ nuinbcr o! l.lnoly.zcd !H1mrl~a llud c:.:cecd lhe moxi1r.um (1Jnrl/or minimum a.s llpproprl~to) pcnnjL conditions in the column:. l"llcJcd 11No. E>:. 11 If nc..nc::, t:ntcr 110. SpccHy frequency of hnnlyi:.is Car each porMnctcr os No. anoly&cs/No. doyio. (o.fl., "J/7" Is 0<1uJva* lont 'o 3 mull}'Sus pcrlom1od ovcry 7 day.::.) If coolinuc.us enter CONT." 120*271 I 28 *2'l ~ 130-311 TO 3 1 VEAR t.10 DAV QUANTITY l*!*~J) I D4-0 ti {02*431 NO, AVERAGE MAKIMUM UNITS EK 5800 13300 M8TUHR

Am 16300.00 233.6 1598.4 HGD

~

s. Specify ::inmplo typo {

11 ~cnb" or -hr. composito") us to.Vplicoblc.

  • U frequency wa~ conlinuoun, cntar NA*
6.
1.

Appropriate sic:noturo ls required on Wltom oC thio Conn. Rcmovo carbon und retain copy for your records.

8. Fold 11lonll dolled llnos, oluple and mall Original to ot'llcc *peclflcd In pcrmil.

10'4*1\\fll ( 4 C4.ltd unly) CONCENTRATION FREQUENCY l !S*4:1) I ~11-c.JJ 1:..c-r.11 ld,*631 Of NO. MINIMUM AVERAGE MAKIMUM UNITS 1'X ANALYSIS CALC HKCLOY 111

  • CALC f--

MGD CONT ~ .A I 100*701 SAMPLE 7YP1' N/A N/A UAME OF PRIHCIPAL EXECUTIVE OFFICER TITLE OF THE OFFICER DATE \\_/f JXL1tt:. ._, / s(;lm.eider, iL.81 01 4111 1 1 ccrt!fy that I um fomlJ/lJr wltl1 lht} Jnfonnnt,on contained in this F. w. V.P. - Production 1i::p1}(t itncl lhat to l11u best of my knowlt!df1CJ and bu/Jul sucl1 i;1for* SIG*IATURr;./OF PlllNCIPAL EXECUTIVE malion ls truo, coriiplolo, li.nrl.accurnto. LAST FIRST Ml TITl.E YEAR MO OAY OFFICER OR AUTHOR\\2.EO AGCNT i:P.i. F~'"' ma.1110-12;D IS IS TOTAL Ofi DISCHARGES 481 1 482,'t83*'*84,485 1 486.

  • ---.. --------- ~. -.

FLrw HEAS CONT FOR ALL CONT DISCH, FOR INT~RHITTE~~AGE ORIClllAL OF T nr~ F(OW MEAS AT FREQ OF HOST FREQ SAHP PARAMETER. 17.5.18 I

0 PS~G* Public Service Electric and Gas Company Salem Nuclear Generating Station P.O. Box# 168 Hancocks Bridge, New Jersey 08038 April 7, 1978 Director, Division of Water Resources N. J. Department of Environmental Protection P. o. Box 2809 Trenton, New Jersey 08625 Attention: Delaware Basin

Dear Sir:

Attached is the Operating Report for the month of March, 1978 for the Industrial Waste Treatment Plant for Salem Generating Station. Very truly yours, <;{Y; 11;'/7. V(>;-/~!d(_~- l H. J. Heller Manager - Salem Generating Station JMZ:jcm 15.5.18.Rl-SHP The Energy People 95-2189 (5M) 10-72 J

....... :_... ~'-

  • ~" MONTHLY _O~E.R.f\\.TING.PORT OF INDUSTRIAL WASTE.EATMENT PLANT PUBLIC RVICE ELECTRIC AND GAS C ANY Salem GENERATING STATION 0HACKENSACK RIVER Hancocks :Bridge NEW JERSEY

~DELAWARE RIVER FOR

March, 19 78 0 INTERSTATE SANITATION COMMISSION

!>!SCH. WASTE STR!:AM Discharged By CLARI FUR BEFORE KIX, BEFORE M!XIRG Daw LTldustrial Svc. OPERATIOU '° ("J <"6 0 0 lol Cl = I-< w Cl I-< I( ~ 1:1>0 I( ~o ..;o WO

0:0 0

0 o..c 0 ..:i 0 ro 0 1-<0 = M co I-< ~~ r..o 0 .,0 w 0'"' I lolO

== "' 0 I <..C =>< 0 = I-< = I-< 0 I I 0: =J. >C ~ >C c

2~
i:
i:

0 0

a:
s:
i:

=>W !:!r lol =>., Cl::> lol w oo.. 0

Ot.>

Q 0 0 ..:I =o I-< ,.JOO 0 ..:i ..:i <..:I <..:I 1 155 95 252 2 285 100 90 ~ 96.7 103 11_7 4 121 107 5 145 103 f, 162 109 qn 7 345 100 216 8 261 105 i::>fi 9 132 95 90 0 291 105 ~t:;1 1 215 105 -:in,::; 56.7 95 ?4

c.

3 225 95 .:;nq -4 42.2 q5 '5 154 70 216 6 438 70 ?~R t:; 7 79.7 70* 144 ... 8 87.1 70 E-1 _g 69.9 70 ~ bo 55.0 70 rnn Dl 79.0 70 ~ ~2 89.6 70 1 q2 (/) ~~ ~4 131.5 70 ?1 h. 0 t>5 87.6 70 72 --~ D6

nq
j

~7 75.2 70" l; 28 fij ~9. 243 70 1RO I:"' rn 59.2 70 !E 31 77.5 70 97 00 \\VG. 137.4 121 BYPASS OPERATION . ~ -~ "'VG. REMARKS All waste automatically discharged between 6.Q-~.Q :12H. bYe:i:::age js for 31 days whether discharge occurred or not. 1, fd.4 /,~,£~' fl Signature of' Licensee ~~e Performance Engineer {/- ~nagerp-f.Zr!fi~_/** 15.. 5.. 18.Rl 7}}