ML19030A831

From kanterella
Jump to navigation Jump to search
Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 1301-1312
ML19030A831
Person / Time
Site: Clinch River
Issue date: 01/18/2019
From: James Shea
Tennessee Valley Authority
To:
Office of New Reactors
Fetter A
References
TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.6, CRN.P.PART08, CRN.P.PART08.2
Download: ML19030A831 (12)


Text

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 153.

154.

155.

156.

157.

158.

159.

AMEC Project 6468-13-1072

-N160 35 Primary-structure Planar Bedding

-N315 33 Fracture Discontinuous Hairline-fractun

-N154 43 Primary-structure Planar Bedding

-N317 40 Fracture Discontinuous Hairline-fractun

-N153 39 Primary-structure Planar Bedding

-N163 45 Primary-structure Planar Bedding

-N154 41 Primary-structure Planar Bedding MP-418A 159.760to 152.392ft 15 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 15 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1299 of 1847 RCN: CRP-111 0.0 Page C1-1301 of 1849

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 160.

161.

162.

163.

164.

165.

166.

167.

AMEC Project 6468-13-1072

N149 38 Primary-structure Planar Bedding

-N322 41 Fracture Discontinuous Hairline-fractun

-N321 40 Fracture Discontinuous Hairline-fractun

-N152 45 Primary-structure Planar Bedding

-N162 38 Primary-structure Planar Bedding

-N147 45 Primary-structure Planar Bedding

-N146 44 Primary-structure Planar Bedding MP-418A 167.128to 159.760ft 16 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 16 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1300 of 1847 RCN: CRP-111 0.0 Page C1-1302 of 1849

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 168.

169.

170.

171.

172.

173.

174.

AMEC Project 6468-13-1072

-N157 44 Primary-structure Planar Bedding

-N155 41 Primary-structure Planar Bedding

-N323 32 Fracture Discontinuous Hairline-fractun

~N160 39 Primary-structure Planar Bedding

-N322 49 Fracture Discontinuous Hairline-fractun MP-418A 174.496to 167.128ft 17 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 17 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1301 of 1847 RCN: CRP-111 0.0 Page C1-1303 of 1849

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 175.

176.

177.

178.

179.

180.

181.

AMEC Project 6468-13-1072

-N160 44 Primary-structure Planar Bedding

-N156 42 Primary-structure Planar Bedding

-N148 45 Primary-structure Planar Bedding

-bit marking MP-418A 181.864to 174.496ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 18 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1302 of 1847 RCN: CRP-111 0.0 Page C1-1304 of 1849 18

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 182.

183.

184.

185.

186.

187.

188.

AMEC Project 6468-13-1072

-N146 38 Primary-structure Planar Bedding

-N157 56 Fracture Planar Hairline-fracture

-N142 37 Primary-structure Planar Bedding

-N142 41 Primary-structure Planar Bedding

-N182 40 Primary-structure Planar Bedding

-N175 45 Primary-structure Irregular Bedding

-N154 49 Primary-structure Irregular Bedding

-N153 39 Primary-structure Planar Bedding

-N336 47 Fracture Discontinuous Hairline-fractun 189.

MP-418A 189.232 to 181.864ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 19 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1303 of 1847 RCN: CRP-111 0.0 Page C1-1305 of 1849 19

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 190.

191.

192.

193.

194.

195.

AMEC Project 6468-13-1072

-N149 36 Primary-structure Planar Bedding

-N150 46 Primary-structure Planar Bedding

-N163 43 Primary-structure Planar Bedding

-N161 36 Primary-structure Planar Bedding

-N159 36 Primary-structure Planar Bedding 196.

-N347 53 Fracture Discontinuous Hairline-fractun

-N159 39 Primary-structure Planar Bedding MP-418A 196.600to 189.232ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 20 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1304 of 1847 RCN: CRP-111 0.0 Page C1-1306 of 1849 20

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N156 38 Primary-structure Planar Bedding

-N163 36 Primary-structure Planar Bedding

-N159 35 Primary-structure Planar Bedding

-N152 37 Primary-structure Planar Bedding

-N299 54 Fracture Discontinuous Hairline-fractun MP-418A 203.968 to 1 96.600ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 21 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1305 of 1847 RCN: CRP-111 0.0 Page C1-1307 of 1849 21

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N151 35 Primary-structure Planar Bedding

-N317 48 Fracture Planar Hairline-fracture

-N154 37 Primary-structure Planar Bedding

-N161 41 Primary-structure Planar Bedding

-N153 38 Primary-structure Planar Bedding

-N151 37 Primary-structure Planar Bedding MP-418A 211.336 to 203.968ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 22 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1306 of 1847 RCN: CRP-111 0.0 Page C1-1308 of 1849 22

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 212.

213.

214.

215.

216.

217.

218.

AMEC Project 6468-13-1072

-N168 43 Primary-structure Planar Bedding

-N139 29 Primary-structure Planar Bedding MP-418A 218.704 to 211.336ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 23 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1307 of 1847 RCN: CRP-111 0.0 Page C1-1309 of 1849 23

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N155 37 Primary-structure Planar Bedding

-N151 35 Primary-structure Planar Bedding

-N149 37 Primary-structure Planar Bedding

-N162 36 Primary-structure Planar Bedding

-N298 38 Fracture Discontinuous Hairline-fractun

-N162 35 Primary-structure Planar Bedding MP-418A 226.072 to 218.704ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 24 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1308 of 1847 RCN: CRP-111 0.0 Page C1-1310 of 1849 24

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N149 41 Primary-structure Planar Bedding

-N149 40 Primary-structure Planar Bedding MP-418A 233.440 to 226.072ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 25 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1309 of 1847 RCN: CRP-111 0.0 Page C1-1311 of 1849 25

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N151 37 Primary-structure Planar Bedding

-N316 65 Fracture Irregular Hairline-fracture

-N148 32 Primary-structure Planar Bedding MP-418A 240.808 to 233.440ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 26 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 131 0 of 1847 RCN: CRP-111 0.0 Page C1-1312 of 1849 26