ML19030A821
| ML19030A821 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 01/18/2019 |
| From: | James Shea Tennessee Valley Authority |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.6, CRN.P.PART08, CRN.P.PART08.2 | |
| Download: ML19030A821 (12) | |
Text
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072 MP-418A 71.344 to 63.976f1 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 3 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1289 of 1849 January 11, 2014 Page 1287 of 1847 RCN: CRP-111 0.0 3
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072 MP-418A 78.712 to 71.344f1 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 4 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1290 of 1849 January 11, 2014 Page 1288 of 1847 RCN: CRP-111 0.0 4
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-bottom of steel casing
-N157 49 Primary-structure Planar Bedding
-N154 48 Primary-structure Planar Bedding
-N155 48 Fracture Planar Open-fracture
-N327 54 Fracture Discontinuous Hairline-fractun
-N152 46 Primary-structure Planar Bedding
-N154 43 Fracture Planar Open-fracture
-N139 44 Fracture Planar Hairline-fracture
-N147 38 Fracture Planar Open-fracture MP-418A 86.080 to 78.712f1 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 5 of37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1291 of 1849 January 11, 2014 Page 1289 of 1847 RCN: CRP-111 0.0 5
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-418A 93.448 to 86.080f1 AMEC Project 6468-13-1072
-N168 45 Fracture Planar Hairline-fracture
-N316 55 Fracture Planar Hairline-fracture
-N151 40 Fracture Planar Open-fracture
-N150 41 Primary-structure Planar Bedding
-N145 44 Primary-structure Planar Bedding
-N152 46 Primary-structure Planar Bedding
-N088 74 Fracture Planar Hairline-fracture
-N148 45 Primary-structure Planar Bedding
-N135 46 Primary-structure Planar Bedding
-N153 45 Primary-structure Planar Bedding
-N158 44 Primary-structure Planar Bedding
-N151 48 Primary-structure Planar Bedding
-N292 58 Fracture Irregular Hairline-fracture AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 6 of37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1292 of 1849 January 11, 2014 Page 1290 of 1847 RCN: CRP-111 0.0 6
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-N150 46 Primary-structure Planar Bedding
-N146 44 Primary-structure Planar Bedding
-N159 43 Primary-structure Planar Bedding
-N339 44 Fracture Planar Hairline-fracture
-N159 48 Primary-structure Planar Bedding
-N154 44 Primary-structure Planar Bedding MP-418A 100.816 to 93.448f1 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 7 of37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1293 of 1849 January 11, 2014 Page 1291 of 1847 RCN: CRP-111 0.0 7
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 101.
102.
103.
104.
105.
106.
107.
108.
AMEC Project 6468-13-1072
~N046 61 Fracture Discontinuous Hairline-fractun
-N156 39 Primary-structure Planar Bedding
-N151 38 Primary-structure Planar Bedding
-N149 42 Primary-structure Planar Bedding
-N161 47 Primary-structure Planar Bedding
-N164 38 Primary-structure Planar Bedding
-N156 42 Primary-structure Planar Bedding
-N154 41 Primary-structure Planar Bedding
-N332 68 Fracture Discontinuous Hairline-fractun
-N155 45 Primary-structure Planar Bedding MP-418A 108.184to 100.816ft 8
AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 8 of37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1294 of 1849 January 11, 2014 Page 1292 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-N150 43 Primary-structure Planar Bedding
-N151 40 Primary-structure Planar Bedding
-N153 38 Primary-structure Planar Bedding
-N320 25 Fracture Planar Hairline-fracture
-N150 41 Primary-structure Planar Bedding
-N311 42 Fracture Planar Hairline-fracture
-N151 48 Primary-structure Planar Bedding MP-418A 115.552 to 108. 184ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 9 of37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1295 of 1849 January 11, 2014 Page 1293 of 1847 RCN: CRP-111 0.0 9
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 116.
117.
118.
119.
120.
121.
122.
AMEC Project 6468-13-1072
-N153 45 Primary-structure Planar Bedding MP-418A 122.920to 115.552ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 1 0 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1294 of 1847 RCN: CRP-111 0.0 Page C1-1296 of 1849 10
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 123.
124.
125.
126.
127.
128.
129.
130.
AMEC Project 6468-13-1072
-N133 51 Primary-structure Planar Bedding
-N157 46 Primary-structure Planar Bedding
-N154 42 Primary-structure Planar Bedding
-N146 38 Primary-structure Planar Bedding MP-418A 130.288to 122.920ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 11 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1295 of 1847 RCN: CRP-111 0.0 Page C1-1297 of 1849 11
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-418A 137.656to 130.288ft AMEC Project 6468-13-1072
-N157 42 Primary-structure Planar Bedding
-N161 43 Primary-structure Planar Bedding
-N347 42 Fracture Discontinuous Hairline-fractun
-N316 43 Fracture Discontinuous Hairline-fractun
-N150 43 Primary-structure Planar Bedding
-N331 39 Fracture Planar Hairline-fracture
-N154 40 Primary-structure Planar Bedding
-N152 41 Primary-structure Planar Bedding
-N149 46 Primary-structure Planar Bedding 12 AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 12 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1298 of 1849 January 11, 2014 Page 1296 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 138.
139.
AMEC Project 6468-13-1072
-N157 46 Primary-structure Planar Bedding
-N155 47 Primary-structure Planar Bedding
-N338 45 Fracture Discontinuous Hairline-fractun 140.
-N149 39 Fracture Planar Open-fracture
-N152 41 Primary-structure Planar Bedding 141.
-N146 47 Primary-structure Planar Bedding 142.
-N154 43 Fracture Planar Open-fracture
-N165 43 Primary-structure Planar Bedding 143.
-N177 58 Primary-structure Planar Bedding 144.
-N168 56 Primary-structure Planar Bedding
-N164 57 Primary-structure Planar Bedding 145.
tN174 48 Prim~rv-structure Pl~n~r Beddina MP-418A 145.024to 137.656ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 13 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1297 of 1847 RCN: CRP-111 0.0 Page C1-1299 of 1849 13
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 146.
147.
148.
149.
150.
151.
152.
AMEC Project 6468-13-1072
-N174 48 Primary-structure Planar Bedding
-N175 40 Primary-structure Planar Bedding
-N145 38 Primary-structure Planar Bedding
-N155 48 Primary-structure Planar Bedding MP-418A 152.392 to 145.024ft AMEC Clinch River SMR Project Borehole MP-418A Acoustic Televiewer Features rev 2 Sheet 14 of 37 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1298 of 1847 RCN: CRP-111 0.0 Page C1-1300 of 1849 14