AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project MP-409 53.172 to 45.804f1 AMEC Project 6468-13-1072

-bottom of steel casing

-N152 39 Primary-structure Planar Bedding

-N175 31 Primary-structure Planar Bedding

-change in diameter

-N152 35 Primary-structure Planar Bedding

-N144 31 Primary-structure Planar Bedding

-N163 36 Primary-structure Planar Bedding

-N153 36 Primary-structure Planar Bedding

-N154 34 Primary-structure Planar Bedding AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 3 of30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-1101 of 1849 January 11, 2014 Page 1 099 of 1847 RCN: CRP-111 0.0 3

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N157 37 Primary-structure Planar Bedding

-N151 31 Primary-structure Planar Bedding

-N162 36 Primary-structure Planar Bedding

-N158 34 Primary-structure Planar Bedding

-N155 35 Primary-structure Planar Bedding

-N160 33 Primary-structure Planar Bedding

-N155 34 Primary-structure Planar Bedding

-N143 37 Primary-structure Planar Bedding

-N164 35 Primary-structure Planar Bedding

-N162 34 Primary-structure Planar Bedding

-N152 34 Primary-structure Planar Bedding

-N156 34 Primary-structure Planar Bedding

-N157 36 Primary-structure Planar Bedding

-N157 33 Primary-structure Planar Bedding MP-409 60.540 to 53.172f1 AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 4 of30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1100 of 1847 RCN: CRP-111 0.0 Page C1-1102 of 1849 4

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 61.0 62.0 63.0 64.0 65.0 66.0 67.0 AMEC Project 6468-13-1072

-N162 36 Primary-structure Planar Bedding

-N158 36 Primary-structure Planar Bedding

-N163 37 Primary-structure Planar Bedding

-N157 39 Primary-structure Planar Bedding

-N160 36 Primary-structure Planar Bedding

-N160 39 Primary-structure Planar Bedding

-N154 36 Primary-structure Planar Bedding

-N160 39 Primary-structure Planar Bedding

-N157 36 Primary-structure Planar Bedding

-N146 30 Primary-structure Planar Bedding

-N158 38 Primary-structure Planar Bedding

-N162 35 Primary-structure Planar Bedding MP-409 67.908 to 60.540f1 AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 5 of30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1101 of 1847 RCN: CRP-111 0.0 Page C1-1103 of 1849 5

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N157 33 Primary-structure Planar Bedding

-N316 46 Fracture Planar Hairline-fracture

-N162 35 Primary-structure Planar Bedding

-N160 39 Primary-structure Planar Bedding

-N167 36 Primary-structure Planar Bedding

-N321 51 Fracture Planar Hairline-fracture

-N161 34 Primary-structure Planar Bedding

-N155 35 Primary-structure Planar Bedding

-N154 40 Primary-structure Planar Bedding

-N171 38 Primary-structure Planar Bedding

-N161 41 Primary-structure Planar Bedding

-N162 36 Primary-structure Planar Bedding

-N160 44 Primary-structure Planar Bedding

-N333 47 Fracture Discontinuous Hairline-fractun MP-409 75.276 to 67.908f1 AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 6 of30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1102 of 1847 RCN: CRP-111 0.0 Page C1-1104 of 1849 6

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N326 41 Fracture Planar Hairline-fracture

-N170 39 Primary-structure Planar Bedding

-N161 32 Primary-structure Planar Bedding

-N340 55 Fracture Discontinuous Hairline-fractun

-N151 28 Primary-structure Planar Bedding

-N151 30 Primary-structure Planar Bedding

-N165 42 Primary-structure Planar Bedding

-N164 31 Primary-structure Planar Bedding

-N163 32 Primary-structure Planar Bedding MP-409 82.644 to 75.276f1 AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 7 of30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1103 of 1847 RCN: CRP-111 0.0 Page C1-1105 of 1849 7

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N155 29 Primary-structure Planar Bedding

-N159 39 Primary-structure Planar Bedding

-N160 37 Primary-structure Planar Bedding

-N166 35 Primary-structure Planar Bedding

-N165 32 Primary-structure Planar Bedding

-N171 33 Primary-structure Planar Bedding

-N162 36 Primary-structure Planar Bedding

-N166 34 Primary-structure Planar Bedding

-N171 32 Primary-structure Planar Bedding MP-409 90.012 to 82.644f1 AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 8 of30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1104 of 1847 RCN: CRP-111 0.0 Page C1-1106 of 1849 8

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project

~,..

~~~

~;... ~

~-

~

~**

~~ ~ ~~1

?:.....,.. ~~

~

i'

~

I**

I

    • ~

1'1""1' I

~

..: I

t"

~. J l '*

I' AMEC Project 6468-13-1072

~

~

~

/

~

-N163 36 Primary-structure Planar Bedding

~...;.

~

\\

~

~

~

-N329 33 Fracture Planar Hairline-fracture

~

/

~

-N160 31 Primary-structure Planar Bedding

~

/

~

-N170 36 Primary-structure Planar Bedding I ~

/

~

-N159 35 Primary-structure Planar Bedding I ~

/

~

-N157 35 Primary-structure Planar Bedding

~"' ~

-N172 30 Primary-structure Planar Bedding MP-409 97.380 to 90.012f1 AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 9 of30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1105 of 1847 RCN: CRP-111 0.0 Page C1-1107 of 1849 9

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project I

-- - -- -- -~ - -- -

I 1"-

I l'

~-

I 1..

..... ~

102.0 I'

I I

103.0

  • ~

104.0

~

~

AMEC Project 6468-13-1072

~

~

-N160 28 Primary-structure Planar Bedding II

~

/

~

-N163 33 Primary-structure Planar Bedding I*

~

/

~

-N159 31 Primary-structure Planar Bedding K

// ~

-N159 33 Primary-structure Planar Bedding

~

~

-N160 28 Primary-structure Planar Bedding K

/

~

-N161 32 Primary-structure Planar Bedding I ~

/

~

-N168 36 Primary-structure Planar Bedding J

MP-409 104.748 to 97.380f1 AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 10 of 30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1106 of 1847 RCN: CRP-111 0.0 Page C1-1108 of 1849 10

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project

~

~

105.0 oo r

106.0 107.0 108.0

~ '.

109.0

~

~-,..

110.0 0

0

~ ~:<":., _. ; cf

olt.-

111.0 I

\\

i.

  • ~*'

112.0 AMEC Project 6468-13-1072 I

/

~

-N152 28 Primary-structure Planar Bedding I\\

I I ~

~

-N164 25 Primary-structure Planar Bedding

/

~

-N155 27 Primary-structure Planar Bedding

/

-N158 29 Primary-structure Planar Bedding I\\

~

/

-N157 32 Primary-structure Planar Bedding 0

/

/

-N168 42 Primary-structure Planar Bedding

~

~

-N177 27 Primary-structure Planar Bedding i'*

! ~

~

// ~

-N159 37 Primary-structure Planar Bedding MP-409 112.116 to 104.748ft AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 11 of 30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1107 of 1847 RCN: CRP-111 0.0 Page C1-1109 of 1849 11

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project I

113.0

/

114.0

~-

c 115.0

~

AMEC Project 6468-13-1072 l

~

~

-N163 29 Primary-structure Planar Bedding I ~

1.....

li

/

~

-N173 35 Primary-structure Planar Bedding li

/

~

-N175 34 Primary-structure Planar Bedding I

1 I\\

/

~

-N163 34 Primary-structure Planar Bedding

/ ~ "

14

~

~

-N313 39 Fracture Discontinuous Hairline-fractun

~

116.0

~.

/

-N150 28 Primary-structure Planar Bedding i\\

~-

_. ~

r~... ), ¥7 *~

I ~

r~,..

/

~

-N159 30 Primary-structure Planar Bedding

"'*....:. -~

I\\

,"":ol....

117.0

~,._.... *

r...
~ *;'>-

~-

t-

  • "... ~~ i_

~

/

~

-N169 33 Primary-structure Planar Bedding 118.0 I

.~

I

'* ~;

-~

~ /

~

/

~

-N160 32 Primary-structure Planar Bedding i'

t*

119.0

  • ~::::-,

.,~..

/

~

  • ~ * ;.

-N152 29 Primary-structure Planar Bedding

!\\

MP-409 119.484 to 112.116ft AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 12 of 30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1108 of 1847 RCN: CRP-111 0.0 Page C1-1110 of 1849 12

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project

f. :,..

..., ~.

120.0

~ ---- - -- ~ --

~

/

121.0

~-:-* *,

"~

1.!*

I~

, f*~:

to-

  • ~..

122.0

"" r X

~ ~

ll.:

    • ~- ;;... ~

~* ~:

~

123.0 I*

I'"

~

i* -

,,:~

jo<

I

. \\~:

~**

    • ~

~ i ;o:_:

i*

.1.

124.0 f'

~ *

~

i.o"' '

~-

I..J-

~ =* '

~..

~

  • ~

t<

125.0 I*

I

-~

~

~.

. ~

/

~-

~

i*

,II 126.0

~..

I,_. :~

[J'

~-;:

~**.

~~~-

j,*

AMEC Project 6468-13-1072

/

-N149 27 Primary-structure Planar Bedding I\\

/

-N154 30 Primary-structure Planar Bedding I\\

I\\

\\

~ <

-N158 33 Primary-structure Planar Bedding

-N337 52 Fracture Planar Hairline-fracture I\\

/

~

-N158 34 Primary-structure Planar Bedding

~

~

-N163 29 Primary-structure Planar Bedding

!I I\\

_/ ~

-N157 33 Primary-structure Planar Bedding I

/

~

-N166 29 Primary-structure Planar Bedding

!I MP-409 126.852 to 11 9.484ft AMEC Clinch River SMR Project Borehole MP-409 Acoustic Televiewer Features rev 2 Sheet 13 of 30 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1109 of 1847 RCN: CRP-111 0.0 Page C1-1111 of 1849 13