ML19030A690

From kanterella
Jump to navigation Jump to search
Letter Service Water System; Shear Pin Failure Safety Evaluation
ML19030A690
Person / Time
Site: Salem  
(DPR-070, DPR-075)
Issue date: 03/03/1978
From: Schwalje E
Public Service Electric & Gas Co
To: Grier B
NRC/IE, NRC Region 1
References
Download: ML19030A690 (1)


Text

, "

Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 Phone 201 /622-7000 March 3, 1978 Mr. Boyce H. Grier, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement

.Region 1 631 Park Avenue King of. Prussia, Pennsylvania 19406

Dear Mr. Grier:

SERVICE WATER SYSTEM SHEAR PIN FAILURE SAFETY EVALUATION 10 CFR PART 21

  • NO. 1 UNIT SALEM NUCLEAR GENERATING STATION This is to confi~m the telephone conversation between Mr. A. Davis, Section Chief, Reactor Projects Seetion No. 1 ~f NRC, Region 1 and the PSE&G Manager -

Quality Assurance of March 2, 1978~

The telecon was pursuant to the 10 CFR Part 21 verbal report

.provided on March 1, 1978 conceining the safety evaluation in~

valving shear pin failure in four service water pump strainers.

As per Q.iscussion, this item will be reported under Prompt Notification with Written Followup" as a Licensee Event Report.

Our telecon of March 1, 1978 satisfies the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> reporting re-quirement and the other written report will follow.

We understand that this reporting procedure will ~atisfy all the requi~ements under 10 CFR Part 21 ~nd no other reports a~e required.

CC Dr. Ernest Volgenau Bethesda, Md.

20014 v4; you~s, E. N. Schw~

Manager -

Quality Assurance Engineering and Construction Department

~