{{#Wiki_filter:AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-422 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (ft/s) (m) (m/s) 144.3 7580 13760 0.28 44.0 2310 145.9 6960 13330 0.31 44.5 2120 147.6 6700 13050 0.32 45.0 2040 149.2 6560 12410 0.31 45.5 2000 150.8 6460 12530 0.32 46.0 1970 152.5 6700 12790 0.31 46.5 2040 154.1 6840 12660 0.29 47.0 2090 155.8 7070 12920 0.29 47.5 2160 157.4 7070 12530 0.27 48.0 2160 159.0 6960 12790 0.29 48.5 2120 160.7 6730 12410 0.29 49.0 2050 162.3 6630 12530 0.31 49.5 2020 164.0 6460 12920 0.33 50.0 1970 165.6 6360 12410 0.32 50.5 1940 167.2 6460 12530 0.32 51.0 1970 168.9 6770 12790 0.31 51.5 2060 170.5 6840 12920 0.30 52.0 2090 172.2 6840 13050 0.31 52.5 2090 173.8 6960 13330 0.31 53.0 2120 175.4 7360 13610 0.29 53.5 2240 177.1 7810 13910 0.27 54.0 2380 178.7 7860 14390 0.29 54.5 2400 180.4 7770 14720 0.31 55.0 2370 182.0 8120 15070 0.30 55.5 2470 183.6 8270 16230 0.32 56.0 2520 185.3 8670 16880 0.32 56.5 2640 186.9 9040 17340 0.31 57.0 2760 188.6 9240 17340 0.30 57.5 2820 190.2 9310 17110 0.29 58.0 2840 191.8 9380 17340 0.29 58.5 2860 193.5 9450 17110 0.28 59.0 2880 195.1 9660 17340 0.27 59.5 2950 196.8 9590 17110 0.27 60.0 2920 198.4 9450 16660 0.26 60.5 2880 200.0 9170 16440 0.27 61.0 2800 201.7 8850 16030 0.28 61.5 2700 203.3 8550 15830 0.29 62.0 2610 205.0 8550 15830 0.29 62.5 2610 206.6 8670 15440 0.27 63.0 2640 208.2 9040 16230 0.27 63.5 2760 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-601 of 1849 Poisson's Vo Ratio (m/s) 4190 0.28 4060 0.31 3980 0.32 3780 0.31 3820 0.32 3900 0.31 3860 0.29 3940 0.29 3820 0.27 3900 0.29 3780 0.29 3820 0.31 3940 0.33 3780 0.32 3820 0.32 3900 0.31 3940 0.30 3980 0.31 4060 0.31 4150 0.29 4240 0.27 4380 0.29 4490 0.31 4590 0.30 4950 0.32 5150 0.32 5290 0.31 5290 0.30 5210 0.29 5290 0.29 5210 0.28 5290 0.27 5210 0.27 5080 0.26 5010 0.27 4880 0.28 4820 0.29 4820 0.29 4710 0.27 4950 0.27 Page 599 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-422 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (ft/s) (m) (m/s) 209.9 9040 16030 0.27 64.0 2760 211.5 9040 15440 0.24 64.5 2760 213.2 8670 14550 0.22 65.0 2640 214.8 8440 14720 0.26 65.5 2570 216.4 8500 14720 0.25 66.0 2590 218.1 8670 15830 0.29 66.5 2640 219.7 8790 15630 0.27 67.0 2680 221.4 8980 15830 0.26 67.5 2740 223.0 9040 16030 0.27 68.0 2760 224.7 9040 15440 0.24 68.5 2760 226.3 9040 15630 0.25 69.0 2760 227.9 8920 15070 0.23 69.5 2720 229.6 8920 14890 0.22 70.0 2720 231.2 8920 15070 0.23 70.5 2720 232.9 8980 15070 0.22 71.0 2740 234.5 9040 14890 0.21 71.5 2760 236.1 9040 14890 0.21 72.0 2760 237.8 9040 14720 0.20 72.5 2760 239.4 8920 14890 0.22 73.0 2720 241.1 8670 14720 0.23 73.5 2640 242.7 8670 14720 0.23 74.0 2640 244.3 8670 14390 0.21 74.5 2640 246.0 9040 14720 0.20 75.0 2760 247.6 9240 14890 0.19 75.5 2820 249.3 9240 14720 0.17 76.0 2820 250.9 8920 14720 0.21 76.5 2720 252.5 8120 14390 0.27 77.0 2470 254.2 7770 14070 0.28 77.5 2370 255.8 7360 14390 0.32 78.0 2240 257.5 7490 14550 0.32 78.5 2280 259.1 7960 14890 0.30 79.0 2430 260.7 8270 15440 0.30 79.5 2520 262.4 8610 15830 0.29 80.0 2630 264.0 9170 16660 0.28 80.5 2800 265.7 9450 16660 0.26 81.0 2880 267.3 9660 16230 0.23 81.5 2950 268.9 9740 16030 0.21 82.0 2970 270.6 10130 16880 0.22 82.5 3090 272.2 10210 17110 0.22 83.0 3110 273.9 9660 16440 0.24 83.5 2950 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-602 of 1849 Poisson's Vo Ratio (m/s) 4880 0.27 4710 0.24 4440 0.22 4490 0.26 4490 0.25 4820 0.29 4760 0.27 4820 0.26 4880 0.27 4710 0.24 4760 0.25 4590 0.23 4540 0.22 4590 0.23 4590 0.22 4540 0.21 4540 0.21 4490 0.20 4540 0.22 4490 0.23 4490 0.23 4380 0.21 4490 0.20 4540 0.19 4490 0.17 4490 0.21 4380 0.27 4290 0.28 4380 0.32 4440 0.32 4540 0.30 4710 0.30 4820 0.29 5080 0.28 5080 0.26 4950 0.23 4880 0.21 5150 0.22 5210 0.22 5010 0.24 Page 600 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-422 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (ft/s) (m) (m/s) 275.5 9040 16030 0.27 84.0 2760 277.1 9040 16230 0.27 84.5 2760 278.8 9040 16660 0.29 85.0 2760 280.4 9040 16660 0.29 85.5 2760 282.1 9380 16660 0.27 86.0 2860 283.7 9170 17110 0.30 86.5 2800 285.3 9240 16880 0.29 87.0 2820 287.0 9310 17110 0.29 87.5 2840 288.6 9040 16030 0.27 88.0 2760 290.3 8500 15250 0.28 88.5 2590 291.9 7770 14890 0.31 89.0 2370 293.5 6270 14720 0.39 89.5 1910 295.2 7070 15440 0.37 90.0 2160 296.8 7190 16230 0.38 90.5 2190 298.5 9040 16660 0.29 91.0 2760 300.1 9810 17340 0.26 91.5 2990 301.8 9660 17110 0.27 92.0 2950 303.4 9310 16880 0.28 92.5 2840 305.0 9240 16880 0.29 93.0 2820 306.7 9170 17110 0.30 93.5 2800 308.3 9040 17830 0.33 94.0 2760 310.0 9590 18090 0.30 94.5 2920 311.6 9660 18350 0.31 95.0 2950 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-603 of 1849 Poisson's Vo Ratio (m/s) 4880 0.27 4950 0.27 5080 0.29 5080 0.29 5080 0.27 5210 0.30 5150 0.29 5210 0.29 4880 0.27 4650 0.28 4540 0.31 4490 0.39 4710 0.37 4950 0.38 5080 0.29 5290 0.26 5210 0.27 5150 0.28 5150 0.29 5210 0.30 5430 0.33 5510 0.30 5590 0.31 Page 601 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 CLINCH RIVER SMR PROJECT BOREHOLE MP-423 Source to Receiver and Receiver to Receiver Analysis 0 -+- Near-Far Receivers, Vs t-- t-- 20 --o-Source-Near Receiver, Vs t-- t-- -+- Near-Far Receivers, Vp t-- f-- 40 f-- 1- -- --D-Source-Near Receiver, Vp r-- til::! 60 lb. ~ .... ~ ..-;;; 1"'1' ~ ~
- n
80 ~ ~ 1- .. ~ ~ ~ -n. ~
- II 100
-.....r ll: ~ R .J'\\1 rO.P -=t.....- u-c......
- ..t:n.
120 V" ,..t" - c'::F[....... - 140 £ 1L !!!' ~ ~ =--- I": F-a.
- I:
'-0' 1-160
- c.
0\\. '\\ ~ ~ w h( rv-c
- voy....
~ J;r--. 180 ...n.... c..Pill ~ I~ .__,_ ~ -lX't;.. r"' ;:J;'i 200 ,..,.(".r
- '<Y
~ "-1'1 n.-.. r"'lll ~ ~ 220 IIIJI: i2:::' R"1l ~
- :!of i'OII
-......:: l::iO ].,-{...- ...., :::r'- -- 240 ~ ~
- Fw.-
-~ i'.:!~ 260 ~ .... -v-c Jo::::M * ~ l.J" - '-A-280 At bo 1---;11 r1..6* -==.. H 300 .A 1\\.e ..t"P 320 0 5000 10000 15000 20000 25000 VELOCITY (ft/s) Figure A-26: Boring MP-423, Suspension S-R1 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-604 of 1849 January 11, 2014 Page 602 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Table A-26: Boring MP-423, Suspension S-R1 depths and P-and Swwave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-423 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Vs Vp Poisson's Between Source Vs Vp Poisson's (ft) (ft/s) (ft/s) 52.4 7030 15630 0.37 54.0 7280 14720 0.34 55.7 7230 15070 0.35 57.3 7230 14890 0.35 59.0 7450 15070 0.34 60.6 7580 15440 0.34 62.2 7810 15250 0.32 63.9 8060 15250 0.31 65.5 8060 15250 0.31 67.2 7720 15250 0.33 68.8 7630 15440 0.34 70.5 6430 15070 0.39 72.1 6770 14070 0.35 73.7 7280 14390 0.33 75.4 7720 15630 0.34 77.0 8010 15830 0.33 78.7 8170 15830 0.32 80.3 8330 16030 0.31 81.9 8500 16230 0.31 83.6 8550 16440 0.31 85.2 8730 16230 0.30 86.9 8980 15830 0.26 88.5 8980 17580 0.32 90.1 8550 18900 0.37 91.8 8670 18900 0.37 93.4 9040 18900 0.35 95.1 9590 19180 0.33 96.7 9890 19780 0.33 98.3 10290 19780 0.31 100.0 10210 19780 0.32 101.6 10130 19180 0.31 103.3 10050 18350 0.29 104.9 9890 17830 0.28 106.5 9310 17110 0.29 108.2 9040 16660 0.29 109.8 8730 16660 0.31 111.5 9170 17110 0.30 113.1 9890 17580 0.27 114.7 10380 17830 0.24 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-605 of 1849 (m) (m/s) 16.0 2140 16.5 2220 17.0 2210 17.5 2210 18.0 2270 18.5 2310 19.0 2380 19.5 2460 20.0 2460 20.5 2350 21.0 2320 21.5 1960 22.0 2060 22.5 2220 23.0 2350 23.5 2440 24.0 2490 24.5 2540 25.0 2590 25.5 2610 26.0 2660 26.5 2740 27.0 2740 27.5 2610 28.0 2640 28.5 2760 29.0 2920 29.5 3010 30.0 3140 30.5 3110 31.0 3090 31.5 3060 32.0 3010 32.5 2840 33.0 2760 33.5 2660 34.0 2800 34.5 3010 35.0 3160 January 11, 2014 (m/s) 4760 0.37 4490 0.34 4590 0.35 4540 0.35 4590 0.34 4710 0.34 4650 0.32 4650 0.31 4650 0.31 4650 0.33 4710 0.34 4590 0.39 4290 0.35 4380 0.33 4760 0.34 4820 0.33 4820 0.32 4880 0.31 4950 0.31 5010 0.31 4950 0.30 4820 0.26 5360 0.32 5760 0.37 5760 0.37 5760 0.35 5850 0.33 6030 0.33 6030 0.31 6030 0.32 5850 0.31 5590 0.29 5430 0.28 5210 0.29 5080 0.29 5080 0.31 5210 0.30 5360 0.27 5430 0.24 Page 603 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-423 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Vs Vo Poisson's Between Source Vs (ft) (ft/s) (ft/s) 116.4 10290 18090 0.26 118.0 9970 17830 0.27 119.7 9890 17580 0.27 121.3 9810 18090 0.29 122.9 9740 18620 0.31 124.6 10050 18620 0.29 126.2 9970 17830 0.27 127.9 9380 17830 0.31 129.5 8330 16660 0.33 131.1 8120 15630 0.32 132.8 7630 14890 0.32 134.4 7450 13910 0.30 136.1 7670 14890 0.32 137.7 7860 15830 0.34 139.3 8170 16440 0.34 141.0 8170 16030 0.32 142.6 8550 16030 0.30 144.3 7910 15070 0.31 145.9 7670 13910 0.28 147.6 7280 13610 0.30 149.2 7280 14220 0.32 150.8 7450 14890 0.33 152.5 7670 15440 0.34 154.1 7910 16030 0.34 155.8 8220 16660 0.34 157.4 8330 16880 0.34 159.0 8550 17110 0.33 160.7 8920 17580 0.33 162.3 8980 17340 0.32 164.0 8850 16880 0.31 165.6 8330 16660 0.33 167.2 7770 15830 0.34 168.9 7320 15250 0.35 170.5 7450 14720 0.33 172.2 7910 15070 0.31 173.8 8010 15630 0.32 175.4 8380 15070 0.28 177.1 7720 14390 0.30 178.7 7450 13760 0.29 180.4 7280 13760 0.31 182.0 6960 14070 0.34 183.6 6960 14220 0.34 185.3 7280 14390 0.33 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-606 of 1849 (m) (m/s) 35.5 3140 36.0 3040 36.5 3010 37.0 2990 37.5 2970 38.0 3060 38.5 3040 39.0 2860 39.5 2540 40.0 2470 40.5 2320 41.0 2270 41.5 2340 42.0 2400 42.5 2490 43.0 2490 43.5 2610 44.0 2410 44.5 2340 45.0 2220 45.5 2220 46.0 2270 46.5 2340 47.0 2410 47.5 2510 48.0 2540 48.5 2610 49.0 2720 49.5 2740 50.0 2700 50.5 2540 51.0 2370 51.5 2230 52.0 2270 52.5 2410 53.0 2440 53.5 2560 54.0 2350 54.5 2270 55.0 2220 55.5 2120 56.0 2120 56.5 2220 January 11, 2014 Vo Poisson's (m/s) 5510 0.26 5430 0.27 5360 0.27 5510 0.29 5670 0.31 5670 0.29 5430 0.27 5430 0.31 5080 0.33 4760 0.32 4540 0.32 4240 0.30 4540 0.32 4820 0.34 5010 0.34 4880 0.32 4880 0.30 4590 0.31 4240 0.28 4150 0.30 4340 0.32 4540 0.33 4710 0.34 4880 0.34 5080 0.34 5150 0.34 5210 0.33 5360 0.33 5290 0.32 5150 0.31 5080 0.33 4820 0.34 4650 0.35 4490 0.33 4590 0.31 4760 0.32 4590 0.28 4380 0.30 4190 0.29 4190 0.31 4290 0.34 4340 0.34 4380 0.33 Page 604 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-423 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Vs Vo Poisson's Between Source Vs (ft) (ft/s) (ft/s) 186.9 7580 14890 0.33 188.6 7770 15250 0.32 190.2 8060 15830 0.32 191.8 8380 16030 0.31 193.5 8500 15830 0.30 195.1 8330 15630 0.30 196.8 8060 15440 0.31 198.4 7810 15070 0.32 200.0 7360 14390 0.32 201.7 7150 13910 0.32 203.3 7230 14720 0.34 205.0 7030 14890 0.36 206.6 7580 15070 0.33 208.2 8220 15630 0.31 209.9 8550 15830 0.29 211.5 8550 16440 0.31 213.2 8440 15830 0.30 214.8 8270 15250 0.29 216.4 8060 14550 0.28 218.1 7910 14550 0.29 219.7 7770 14890 0.31 221.4 8060 15440 0.31 223.0 8550 15630 0.29 224.7 8980 16660 0.30 226.3 9450 17340 0.29 227.9 9520 17830 0.30 229.6 9170 17830 0.32 231.2 8980 17830 0.33 232.9 8790 17340 0.33 234.5 8500 16440 0.32 236.1 8120 16030 0.33 237.8 7720 15250 0.33 239.4 7360 14550 0.33 241.1 7150 14550 0.34 242.7 7320 14220 0.32 244.3 7720 14550 0.30 246.0 7910 14890 0.30 247.6 8060 15250 0.31 249.3 7810 15830 0.34 250.9 7910 16230 0.34 252.5 7770 16660 0.36 254.2 7400 16230 0.37 255.8 7150 14890 0.35 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-607 of 1849 (m) (m/s) 57.0 2310 57.5 2370 58.0 2460 58.5 2560 59.0 2590 59.5 2540 60.0 2460 60.5 2380 61.0 2240 61.5 2180 62.0 2210 62.5 2140 63.0 2310 63.5 2510 64.0 2610 64.5 2610 65.0 2570 65.5 2520 66.0 2460 66.5 2410 67.0 2370 67.5 2460 68.0 2610 68.5 2740 69.0 2880 69.5 2900 70.0 2800 70.5 2740 71.0 2680 71.5 2590 72.0 2470 72.5 2350 73.0 2240 73.5 2180 74.0 2230 74.5 2350 75.0 2410 75.5 2460 76.0 2380 76.5 2410 77.0 2370 77.5 2260 78.0 2180 January 11, 2014 Vo Poisson's (m/s) 4540 0.33 4650 0.32 4820 0.32 4880 0.31 4820 0.30 4760 0.30 4710 0.31 4590 0.32 4380 0.32 4240 0.32 4490 0.34 4540 0.36 4590 0.33 4760 0.31 4820 0.29 5010 0.31 4820 0.30 4650 0.29 4440 0.28 4440 0.29 4540 0.31 4710 0.31 4760 0.29 5080 0.30 5290 0.29 5430 0.30 5430 0.32 5430 0.33 5290 0.33 5010 0.32 4880 0.33 4650 0.33 4440 0.33 4440 0.34 4340 0.32 4440 0.30 4540 0.30 4650 0.31 4820 0.34 4950 0.34 5080 0.36 4950 0.37 4540 0.35 Page 605 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-423 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Vs Vo Poisson's Between Source Vs (ft) (ft/s) (ft/s) 257.5 7280 14550 0.33 259.1 7400 14890 0.34 260.7 7450 15250 0.34 262.4 8010 15630 0.32 264.0 8790 16660 0.31 265.7 9110 16880 0.29 267.3 9590 17580 0.29 268.9 10050 17830 0.27 270.6 10380 18090 0.25 272.2 10380 18620 0.27 273.9 10640 19180 0.28 275.5 10640 19780 0.30 277.1 10910 20100 0.29 278.8 10910 20750 0.31 280.4 11110 21100 0.31 282.1 11110 21460 0.32 283.7 11300 21100 0.30 285.3 11300 20750 0.29 287.0 11300 21100 0.30 288.6 11110 21100 0.31 290.3 11300 20750 0.29 291.9 11300 21100 0.30 293.5 11110 20750 0.30 295.2 11300 21100 0.30 296.8 11200 21100 0.30 298.5 11410 20100 0.26 300.1 11110 18620 0.22 301.8 11110 19180 0.25 303.4 11610 20750 0.27 305.0 11300 21460 0.31 306.7 11300 22210 0.33 308.3 11510 21460 0.30 310.0 11510 21100 0.29 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-608 of 1849 (m) (m/s) 78.5 2220 79.0 2260 79.5 2270 80.0 2440 80.5 2680 81.0 2780 81.5 2920 82.0 3060 82.5 3160 83.0 3160 83.5 3240 84.0 3240 84.5 3330 85.0 3330 85.5 3380 86.0 3380 86.5 3450 87.0 3450 87.5 3450 88.0 3380 88.5 3450 89.0 3450 89.5 3380 90.0 3450 90.5 3410 91.0 3480 91.5 3380 92.0 3380 92.5 3540 93.0 3450 93.5 3450 94.0 3510 94.5 3510 January 11, 2014 Vo Poisson's (m/s) 4440 0.33 4540 0.34 4650 0.34 4760 0.32 5080 0.31 5150 0.29 5360 0.29 5430 0.27 5510 0.25 5670 0.27 5850 0.28 6030 0.30 6130 0.29 6330 0.31 6430 0.31 6540 0.32 6430 0.30 6330 0.29 6430 0.30 6430 0.31 6330 0.29 6430 0.30 6330 0.30 6430 0.30 6430 0.30 6130 0.26 5670 0.22 5850 0.25 6330 0.27 6540 0.31 6770 0.33 6540 0.30 6430 0.29 Page 606 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 0 20 40 60 80 100 120 -£
- I:
1-140
- c.
w c 160 180 200 220 240 260 280 CLINCH RIVER SMR PROJECT BOREHOLE MP-425 Source to Receiver and Receiver to Receiver Analysis .. ~ K[ 1---+-+--+--+--+---+-tl.l'~ n_
- !'=&"" t:;t..
~ ~~---+~~--~~~~~~+-+-~~~~~~~ lfQ' .. -~- I~ ~ ......_ Near-Far Receivers, Vs +-1-~-+~~-r-~~~~-+---+-r-+-~~~~~ I I 3. --o-Source-Near Receiver, Vs - 1---+-1--+--+---+-+-~~-+---+-~+--+-~~~n~~ii~ 1-" -+- Near-Far Receivers, Vp +-1-~-+~~-r--...,;~~/ 1-;:1.. --o-Source-Near Receiver, Vp - ~ I 0 5000 10000 15000 20000 25000 VELOCITY (ft/s) Figure A-27: Boring MP-425, Suspension S-R1 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-609 of 1849 January 11, 2014 Page 607 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Table A-27: Boring MP-425, Suspension S-R1 depths and P-and Swwave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-425 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (fils) (m) (m/s) 13.0 7770 17110 0.37 4.0 2370 15.0 8220 17110 0.35 4.6 2510 16.3 8790 18090 0.35 5.0 2680 18.0 9110 18090 0.33 5.5 2780 19.6 9310 17110 0.29 6.0 2840 21.2 9310 16660 0.27 6.5 2840 22.9 8500 16030 0.30 7.0 2590 24.5 7320 15630 0.36 7.5 2230 26.2 6810 15070 0.37 8.0 2070 27.8 6270 14720 0.39 8.5 1910 29.4 6060 14550 0.40 9.0 1850 31.1 6630 14550 0.37 9.5 2020 32.7 6700 14890 0.37 10.0 2040 34.4 7230 15440 0.36 10.5 2210 36.0 7860 15830 0.34 11.0 2400 37.6 8440 16230 0.31 11.5 2570 39.3 8670 16660 0.31 12.0 2640 40.9 8010 17340 0.36 12.5 2440 42.6 7150 16440 0.38 13.0 2180 44.2 7230 15630 0.36 13.5 2210 45.8 7070 14720 0.35 14.0 2160 47.5 7030 13910 0.33 14.5 2140 49.1 7110 15250 0.36 15.0 2170 50.8 8220 16660 0.34 15.5 2510 52.4 8500 16030 0.30 16.0 2590 54.0 8270 15440 0.30 16.5 2520 55.7 7860 14070 0.27 17.0 2400 57.3 7490 14220 0.31 17.5 2280 59.0 7320 14390 0.33 18.0 2230 60.6 7030 14220 0.34 18.5 2140 62.2 6990 14390 0.35 19.0 2130 63.9 7110 14220 0.33 19.5 2170 65.5 7110 14720 0.35 20.0 2170 67.2 7190 14550 0.34 20.5 2190 68.8 7360 14720 0.33 21.0 2240 70.5 7630 15070 0.33 21.5 2320 72.1 7860 15630 0.33 22.0 2400 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-610 of 1849 Poisson's Vo Ratio (m/s) 5210 0.37 5210 0.35 5510 0.35 5510 0.33 5210 0.29 5080 0.27 4880 0.30 4760 0.36 4590 0.37 4490 0.39 4440 0.40 4440 0.37 4540 0.37 4710 0.36 4820 0.34 4950 0.31 5080 0.31 5290 0.36 5010 0.38 4760 0.36 4490 0.35 4240 0.33 4650 0.36 5080 0.34 4880 0.30 4710 0.30 4290 0.27 4340 0.31 4380 0.33 4340 0.34 4380 0.35 4340 0.33 4490 0.35 4440 0.34 4490 0.33 4590 0.33 4760 0.33 Page 608 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-425 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (fils) (m) (m/s) 73.7 8270 16230 0.32 22.5 2520 75.7 8610 16440 0.31 23.1 2630 77.0 7770 16440 0.36 23.5 2370 78.7 7630 16660 0.37 24.0 2320 80.3 7960 16880 0.36 24.5 2430 81.9 8010 16880 0.35 25.0 2440 83.9 8610 16660 0.32 25.6 2630 85.2 8550 16230 0.31 26.0 2610 86.9 8270 16440 0.33 26.5 2520 88.5 8060 15630 0.32 27.0 2460 90.1 7860 15630 0.33 27.5 2400 91.8 7720 15440 0.33 28.0 2350 93.4 7630 15440 0.34 28.5 2320 95.1 8010 15630 0.32 29.0 2440 96.7 8120 16030 0.33 29.5 2470 98.3 7860 15830 0.34 30.0 2400 100.0 7770 16030 0.35 30.5 2370 101.6 7580 15250 0.34 31.0 2310 103.3 7490 14720 0.33 31.5 2280 104.9 7670 15250 0.33 32.0 2340 106.5 7810 15630 0.33 32.5 2380 108.2 7960 15250 0.31 33.0 2430 109.8 7960 15440 0.32 33.5 2430 111.5 7860 14890 0.31 34.0 2400 113.1 7810 14720 0.30 34.5 2380 114.7 7770 14720 0.31 35.0 2370 116.4 7670 14720 0.31 35.5 2340 118.0 7670 14550 0.31 36.0 2340 119.7 7670 14220 0.29 36.5 2340 121.3 7670 14390 0.30 37.0 2340 122.9 7770 14220 0.29 37.5 2370 124.6 7810 14550 0.30 38.0 2380 126.2 7810 14390 0.29 38.5 2380 127.9 7540 14550 0.32 39.0 2300 129.5 7450 14550 0.32 39.5 2270 131.5 7320 14550 0.33 40.1 2230 132.8 7230 14220 0.33 40.5 2210 134.4 7490 14220 0.31 41.0 2280 136.1 7770 14550 0.30 41.5 2370 137.7 8120 15830 0.32 42.0 2470 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-611 of 1849 Poisson's Vo Ratio (m/s) 4950 0.32 5010 0.31 5010 0.36 5080 0.37 5150 0.36 5150 0.35 5080 0.32 4950 0.31 5010 0.33 4760 0.32 4760 0.33 4710 0.33 4710 0.34 4760 0.32 4880 0.33 4820 0.34 4880 0.35 4650 0.34 4490 0.33 4650 0.33 4760 0.33 4650 0.31 4710 0.32 4540 0.31 4490 0.30 4490 0.31 4490 0.31 4440 0.31 4340 0.29 4380 0.30 4340 0.29 4440 0.30 4380 0.29 4440 0.32 4440 0.32 4440 0.33 4340 0.33 4340 0.31 4440 0.30 4820 0.32 Page 609 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-425 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (fils) (m) (m/s) 139.7 8670 16030 0.29 42.6 2640 141.0 8500 15250 0.28 43.0 2590 142.6 8120 14890 0.29 43.5 2470 144.3 7770 14720 0.31 44.0 2370 145.9 7190 14550 0.34 44.5 2190 147.6 6880 14390 0.35 45.0 2100 149.2 7230 14550 0.34 45.5 2210 150.8 7400 14220 0.31 46.0 2260 152.5 7770 14220 0.29 46.5 2370 154.1 8010 14220 0.27 47.0 2440 155.8 8270 14220 0.24 47.5 2520 157.4 8060 14220 0.26 48.0 2460 159.0 7910 14390 0.28 48.5 2410 160.7 7770 14220 0.29 49.0 2370 162.3 7580 14220 0.30 49.5 2310 164.0 7320 13910 0.31 50.0 2230 165.6 6840 13470 0.33 50.5 2090 167.2 6630 13610 0.34 51.0 2020 168.9 6460 13470 0.35 51.5 1970 170.5 6240 13190 0.36 52.0 1900 172.2 6330 13050 0.35 52.5 1930 173.8 6490 13190 0.34 53.0 1980 175.4 6730 13470 0.33 53.5 2050 177.1 6960 13610 0.32 54.0 2120 178.7 7280 14220 0.32 54.5 2220 180.4 7400 14720 0.33 55.0 2260 182.0 7540 14720 0.32 55.5 2300 183.6 7670 14720 0.31 56.0 2340 185.3 7770 14720 0.31 56.5 2370 186.9 7810 14890 0.31 57.0 2380 188.9 7860 14720 0.30 57.6 2400 190.2 7860 14550 0.29 58.0 2400 191.8 7860 14720 0.30 58.5 2400 193.5 7810 14550 0.30 59.0 2380 195.1 7810 14550 0.30 59.5 2380 197.1 7630 14390 0.30 60.1 2320 198.4 7540 14220 0.30 60.5 2300 200.0 7360 14070 0.31 61.0 2240 202.0 7150 13910 0.32 61.6 2180 203.3 7030 14070 0.33 62.0 2140 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-612 of 1849 Poisson's Vo Ratio (m/s) 4880 0.29 4650 0.28 4540 0.29 4490 0.31 4440 0.34 4380 0.35 4440 0.34 4340 0.31 4340 0.29 4340 0.27 4340 0.24 4340 0.26 4380 0.28 4340 0.29 4340 0.30 4240 0.31 4110 0.33 4150 0.34 4110 0.35 4020 0.36 3980 0.35 4020 0.34 4110 0.33 4150 0.32 4340 0.32 4490 0.33 4490 0.32 4490 0.31 4490 0.31 4540 0.31 4490 0.30 4440 0.29 4490 0.30 4440 0.30 4440 0.30 4380 0.30 4340 0.30 4290 0.31 4240 0.32 4290 0.33 Page 61 0 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-425 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (fils) (m) (m/s) 205.0 7150 13760 0.31 62.5 2180 206.6 7280 14070 0.32 63.0 2220 208.2 7400 14220 0.31 63.5 2260 209.9 7450 14070 0.31 64.0 2270 211.5 7360 14220 0.32 64.5 2240 213.2 7230 14070 0.32 65.0 2210 214.8 7110 14220 0.33 65.5 2170 216.4 7110 14390 0.34 66.0 2170 218.1 7320 14550 0.33 66.5 2230 219.7 7400 14220 0.31 67.0 2260 221.4 7450 14390 0.32 67.5 2270 223.0 7490 14070 0.30 68.0 2280 224.7 7400 14070 0.31 68.5 2260 226.3 7540 14070 0.30 69.0 2300 227.9 7450 14220 0.31 69.5 2270 229.6 7490 14220 0.31 70.0 2280 231.2 7540 14550 0.32 70.5 2300 232.9 7630 14550 0.31 71.0 2320 234.5 7580 14550 0.31 71.5 2310 236.1 7630 14550 0.31 72.0 2320 237.8 7670 14890 0.32 72.5 2340 239.4 7770 15250 0.32 73.0 2370 241.1 7770 15070 0.32 73.5 2370 242.7 7810 14890 0.31 74.0 2380 244.3 7810 14720 0.30 74.5 2380 246.0 7770 14720 0.31 75.0 2370 247.6 7670 14550 0.31 75.5 2340 249.3 7540 14390 0.31 76.0 2300 250.9 7360 14550 0.33 76.5 2240 252.5 7490 14390 0.31 77.0 2280 254.2 7400 14390 0.32 77.5 2260 255.8 7450 14220 0.31 78.0 2270 257.5 7540 14390 0.31 78.5 2300 259.1 7540 14390 0.31 79.0 2300 260.7 7630 14550 0.31 79.5 2320 262.4 7670 14550 0.31 80.0 2340 264.0 7670 14390 0.30 80.5 2340 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-613 of 1849 Poisson's Vo Ratio (m/s) 4190 0.31 4290 0.32 4340 0.31 4290 0.31 4340 0.32 4290 0.32 4340 0.33 4380 0.34 4440 0.33 4340 0.31 4380 0.32 4290 0.30 4290 0.31 4290 0.30 4340 0.31 4340 0.31 4440 0.32 4440 0.31 4440 0.31 4440 0.31 4540 0.32 4650 0.32 4590 0.32 4540 0.31 4490 0.30 4490 0.31 4440 0.31 4380 0.31 4440 0.33 4380 0.31 4380 0.32 4340 0.31 4380 0.31 4380 0.31 4440 0.31 4440 0.31 4380 0.30 Page 611 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 CLINCH RIVER SMR PROJECT BOREHOLE MP-426 Source to Receiver and Receiver to Receiver Analysis 0 -+- Near-Far Receivers, Vs r-- r-- ~Source-Near Receiver, Vs r-- 20 r-- --- Near-Far Receivers, Vp r-- 40 r-- Ia. --D-Source-Near Receiver, Vp -o: ~ -o.- r-- L.r r--;: !-r-.1!:: I! -~ ~ J ~ x 60 ~ 1..!1""" J&. ~ ::.. :!":I-' r--1 fit:,.,. 80 A!!;. -Y"l._
- j
~ ~ .. ~ Da: :8::11 100 lies: u:::; i&:* ~ '-1 b ~ ~ it"V' iU ........
- tx
- 120 £
- 1' t-a
- F""
- c;::;',;:J_
~ ~ ~
- I:
1-140
- c.
.. ~ L...l'9 ;:;1 '9/J -,.., !Sol 11:: t;:!l! l-' w c ~ ~ .l!!!l IIF r 160 ~ .-'1: J:ll a- ~ pe ~ pe 180 c l'S:: * ~ 'f;;' ~ ~ "i>--111 F :.. s::;; 200 -OJ Ill!,;; [ "P".. ~ ~ 1:11" 220 ~
- "b
_p. g:
- 240
~ '-{ ~ r-a- ~= -.. J 260 ti ..-r:J!I-' ) j-J 280 0 5000 10000 15000 20000 25000 VELOCITY (ft/s) Figure A-28: Boring MP-426, Suspension S-R1 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-614 of 1849 January 11, 2014 Page 612 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Table A-28: Boring MP-426, Suspension S-R1 depths and P-and Swwave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-426 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source Poisson's and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (ft/s) 37.6 6590 11510 0.26 39.3 7150 11940 0.22 40.9 7490 12660 0.23 42.6 8270 13910 0.23 44.2 8850 14390 0.20 44.2 8850 15440 0.26 45.8 9170 16440 0.27 47.5 9170 18620 0.34 49.1 8790 17830 0.34 50.8 8920 18090 0.34 52.4 8550 17340 0.34 54.0 8550 17110 0.33 55.7 8330 17340 0.35 57.3 8790 18090 0.35 59.0 9170 18350 0.33 60.6 9170 17830 0.32 62.2 9040 18900 0.35 63.9 9040 18350 0.34 65.5 9040 19180 0.36 67.2 9170 18350 0.33 68.8 9590 18090 0.30 70.5 9590 18900 0.33 72.1 9450 18090 0.31 73.7 9380 18090 0.32 75.4 9590 17830 0.30 77.0 9310 18900 0.34 78.7 9310 18900 0.34 80.3 9810 17830 0.28 81.9 10380 18350 0.26 83.6 10730 17830 0.22 85.2 11010 18350 0.22 86.9 11110 18350 0.21 88.5 11110 18900 0.24 90.1 10820 18900 0.26 91.8 10380 18900 0.28 93.4 10290 18350 0.27 95.1 10130 19180 0.31 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-615 of 1849 (m) (m/s) 11.5 2010 12.0 2180 12.5 2280 13.0 2520 13.5 2700 13.5 2700 14.0 2800 14.5 2800 15.0 2680 15.5 2720 16.0 2610 16.5 2610 17.0 2540 17.5 2680 18.0 2800 18.5 2800 19.0 2760 19.5 2760 20.0 2760 20.5 2800 21.0 2920 21.5 2920 22.0 2880 22.5 2860 23.0 2920 23.5 2840 24.0 2840 24.5 2990 25.0 3160 25.5 3270 26.0 3360 26.5 3380 27.0 3380 27.5 3300 28.0 3160 28.5 3140 29.0 3090 January 11, 2014 Vo Ratio (m/s) 3510 0.26 3640 0.22 3860 0.23 4240 0.23 4380 0.20 4710 0.26 5010 0.27 5670 0.34 5430 0.34 5510 0.34 5290 0.34 5210 0.33 5290 0.35 5510 0.35 5590 0.33 5430 0.32 5760 0.35 5590 0.34 5850 0.36 5590 0.33 5510 0.30 5760 0.33 5510 0.31 5510 0.32 5430 0.30 5760 0.34 5760 0.34 5430 0.28 5590 0.26 5430 0.22 5590 0.22 5590 0.21 5760 0.24 5760 0.26 5760 0.28 5590 0.27 5850 0.31 Page 613 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-426 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (ft/s) (m) (m/s) 96.7 10460 18350 0.26 29.5 3190 98.3 10550 19180 0.28 30.0 3220 100.0 10640 19180 0.28 30.5 3240 101.9 11720 20420 0.25 31.1 3570 103.3 12170 20750 0.24 31.5 3710 104.9 11940 20100 0.23 32.0 3640 106.5 11510 19780 0.24 32.5 3510 108.2 11300 19180 0.23 33.0 3450 109.8 11010 18900 0.24 33.5 3360 111.5 10460 20100 0.31 34.0 3190 113.1 10380 20420 0.33 34.5 3160 114.7 10550 19480 0.29 35.0 3220 116.4 10210 20100 0.33 35.5 3110 118.0 10380 19180 0.29 36.0 3160 119.7 10130 18620 0.29 36.5 3090 121.3 10210 19780 0.32 37.0 3110 122.9 10130 20420 0.34 37.5 3090 124.6 9520 19180 0.34 38.0 2900 126.2 10460 19480 0.30 38.5 3190 127.9 11110 20420 0.29 39.0 3380 129.5 11830 19780 0.22 39.5 3610 131.1 11510 19480 0.23 40.0 3510 132.8 12290 20100 0.20 40.5 3750 133.8 12060 20100 0.22 40.8 3680 134.4 12410 21100 0.24 41.0 3780 136.1 12060 20750 0.25 41.5 3680 137.7 11510 19480 0.23 42.0 3510 139.3 10910 18900 0.25 42.5 3330 141.0 9740 19180 0.33 43.0 2970 142.6 8920 18900 0.36 43.5 2720 144.3 8920 18350 0.35 44.0 2720 145.9 9170 19180 0.35 44.5 2800 147.6 9890 18900 0.31 45.0 3010 149.2 10550 19480 0.29 45.5 3220 150.8 10460 18350 0.26 46.0 3190 152.5 10550 17580 0.22 46.5 3220 154.1 10550 17830 0.23 47.0 3220 155.8 10820 18900 0.26 47.5 3300 157.4 11110 19180 0.25 48.0 3380 159.0 10730 18350 0.24 48.5 3270 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-616 of 1849 Poisson's Vo Ratio (m/s) 5590 0.26 5850 0.28 5850 0.28 6220 0.25 6330 0.24 6130 0.23 6030 0.24 5850 0.23 5760 0.24 6130 0.31 6220 0.33 5940 0.29 6130 0.33 5850 0.29 5670 0.29 6030 0.32 6220 0.34 5850 0.34 5940 0.30 6220 0.29 6030 0.22 5940 0.23 6130 0.20 6130 0.22 6430 0.24 6330 0.25 5940 0.23 5760 0.25 5850 0.33 5760 0.36 5590 0.35 5850 0.35 5760 0.31 5940 0.29 5590 0.26 5360 0.22 5430 0.23 5760 0.26 5850 0.25 5590 0.24 Page 614 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-426 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (ft/s) (m) (m/s) 160.7 10460 18090 0.25 49.0 3190 162.3 10210 18620 0.28 49.5 3110 164.0 10210 17830 0.26 50.0 3110 165.6 10050 17580 0.26 50.5 3060 167.2 10380 18350 0.26 51.0 3160 168.9 10550 18900 0.27 51.5 3220 170.5 10640 18350 0.25 52.0 3240 172.2 10460 17580 0.23 52.5 3190 173.8 10640 17830 0.22 53.0 3240 175.4 10290 17340 0.23 53.5 3140 177.1 9970 18350 0.29 54.0 3040 178.7 10380 19180 0.29 54.5 3160 180.4 10550 20100 0.31 55.0 3220 182.0 10380 19780 0.31 55.5 3160 183.6 10820 20420 0.30 56.0 3300 185.3 11200 19180 0.24 56.5 3410 186.9 11300 19180 0.23 57.0 3450 188.6 11200 19780 0.26 57.5 3410 190.2 11200 19180 0.24 58.0 3410 191.8 11200 18900 0.23 58.5 3410 193.5 11010 18900 0.24 59.0 3360 195.1 10820 19180 0.27 59.5 3300 196.8 10730 19780 0.29 60.0 3270 198.4 10460 19180 0.29 60.5 3190 200.0 10130 18900 0.30 61.0 3090 201.7 9240 18620 0.34 61.5 2820 203.3 9450 18350 0.32 62.0 2880 205.0 9110 18620 0.34 62.5 2780 206.6 9660 18350 0.31 63.0 2950 208.2 9970 17830 0.27 63.5 3040 209.9 9970 18090 0.28 64.0 3040 211.5 10130 17830 0.26 64.5 3090 213.2 10290 17830 0.25 65.0 3140 214.8 10380 17340 0.22 65.5 3160 216.4 10640 18350 0.25 66.0 3240 218.1 10550 19180 0.28 66.5 3220 219.7 10380 19480 0.30 67.0 3160 221.4 10550 19480 0.29 67.5 3220 223.0 10460 18090 0.25 68.0 3190 224.7 10820 19180 0.27 68.5 3300 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-617 of 1849 Poisson's Vo Ratio (m/s) 5510 0.25 5670 0.28 5430 0.26 5360 0.26 5590 0.26 5760 0.27 5590 0.25 5360 0.23 5430 0.22 5290 0.23 5590 0.29 5850 0.29 6130 0.31 6030 0.31 6220 0.30 5850 0.24 5850 0.23 6030 0.26 5850 0.24 5760 0.23 5760 0.24 5850 0.27 6030 0.29 5850 0.29 5760 0.30 5670 0.34 5590 0.32 5670 0.34 5590 0.31 5430 0.27 5510 0.28 5430 0.26 5430 0.25 5290 0.22 5590 0.25 5850 0.28 5940 0.30 5940 0.29 5510 0.25 5850 0.27 Page 615 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Source-to-Receiver Travel Time Data - Borehole MP-426 American Units Metric Units Depth at Midpoint Velocity Depth at Midpoint Velocity Between Source Poisson's Between Source and Near Receiver Vs Vo Ratio and Near Receiver Vs (ft) (ft/s) (ft/s) (m) (m/s) 226.3 10640 18620 0.26 69.0 3240 227.9 10550 17830 0.23 69.5 3220 229.6 10290 18620 0.28 70.0 3140 231.2 9970 18900 0.31 70.5 3040 232.9 9890 18350 0.30 71.0 3010 234.5 9890 18900 0.31 71.5 3010 236.1 9590 18900 0.33 72.0 2920 237.8 9520 17830 0.30 72.5 2900 239.4 9660 17340 0.27 73.0 2950 241.1 9660 17580 0.28 73.5 2950 242.7 9970 17830 0.27 74.0 3040 244.3 10460 18350 0.26 74.5 3190 246.0 10910 17830 0.20 75.0 3330 247.6 11300 19180 0.23 75.5 3450 249.3 11300 19180 0.23 76.0 3450 250.9 11410 19780 0.25 76.5 3480 252.5 11410 19480 0.24 77.0 3480 254.2 11110 19480 0.26 77.5 3380 255.8 11200 19180 0.24 78.0 3410 257.5 11010 18620 0.23 78.5 3360 259.1 10820 18900 0.26 79.0 3300 260.7 10910 19780 0.28 79.5 3330 262.4 11110 19480 0.26 80.0 3380 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-618 of 1849 Poisson's Vo Ratio (m/s) 5670 0.26 5430 0.23 5670 0.28 5760 0.31 5590 0.30 5760 0.31 5760 0.33 5430 0.30 5290 0.27 5360 0.28 5430 0.27 5590 0.26 5430 0.20 5850 0.23 5850 0.23 6030 0.25 5940 0.24 5940 0.26 5850 0.24 5670 0.23 5760 0.26 6030 0.28 5940 0.26 Page 616 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project APPENDIX 8 AMEC Project 6468-13-1072 ACOUSTIC TELEVIEWER FEATURES GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-619 of 1849 January 11, 2014 Page 617 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project G~Ms,!on BHTV DATA PROCESSING RGLDIP vsn 6.2 geophysical services INTERPRETED BHTV DIPS LOG AMEC Borehole: MP-101 CLINCH RIVER top of borehole..... East: - North:_ Elev: - Zone from 539.396 to 16.7321! Format: BHTV-NESWN Stratigraphic dips Non-stratigraphic dips ~ ARROW PLOT AMEC Project 6468-13-1072 North ref. is true Depth units are feet Vertical scale: 1/10 Horiz scale = 1.00x Vert scale Borehole diam: 3.900inch Vertical = borehole-axis Image: Amplitude Identified units COMMENTS N315o N45o N E s w 20° 60° 90°------+ ------+
- 17.
-surface casing
- 18.
-N154 38 Primary-structure Planar Bedding -N149 34 Primary-structure Planar Bedding
- 19.
/N156 37 Fracture Planar Open-fracture -N335 74 Fracture Discontinuous Hairline-fractun -N153 34 Fracture Planar Open-fracture -N159 35 Primary-structure Planar Bedding
- 20.
-N152 33 Primary-structure Planar Bedding MP-101 20.576 to 16.732f1 AMEC Clinch River SMR Project Borehole MP-1 01 Acoustic Televiewer Features rev 2 Sheet 1 of 72 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-620 of 1849 January 11, 2014 Page 618 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project MP-101 27.944 to 20.576f1 AMEC Project 6468-13-1072 -N163 35 Primary-structure Planar Bedding -N142 31 Primary-structure Planar Bedding -N165 45 Primary-structure Planar Bedding -N330 45 Fracture Discontinuous Hairline-fractun -N161 32 Primary-structure Planar Bedding -N157 30 Primary-structure Planar Bedding -N154 36 Primary-structure Planar Bedding -N347 27 Fracture Discontinuous Hairline-fractun -N149 41 Primary-structure Planar Bedding -N159 32 Primary-structure Planar Bedding -N162 34 Primary-structure Planar Bedding -N175 34 Fracture Planar Open-fracture -N152 31 Primary-structure Planar Bedding -N154 31 Primary-structure Planar Bedding 2 AMEC Clinch River SMR Project Borehole MP-1 01 Acoustic Televiewer Features rev 2 Sheet 2 of72 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-621 of 1849 January 11, 2014 Page 619 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project MP-101 35.312 to 27.944f1 AMEC Project 6468-13-1072 -N153 31 Primary-structure Planar Bedding -N163 31 Primary-structure Planar Bedding -N331 57 Fracture Discontinuous Hairline-fractun -N161 32 Primary-structure Planar Bedding -N160 35 Primary-structure Planar Bedding -N157 35 Primary-structure Planar Bedding -N160 36 Fracture Planar Open-fracture -N160 31 Primary-structure Planar Bedding -N155 34 Primary-structure Planar Bedding -N160 30 Primary-structure Planar Bedding 3 AMEC Clinch River SMR Project Borehole MP-1 01 Acoustic Televiewer Features rev 2 Sheet 3 of72 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-622 of 1849 January 11, 2014 Page 620 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project ~.. I 36.0 !* * :i: ";1 ~*./*.
- ~
-~J -~;;- . ~ - *
- ~.~
....... ~ - - *.... -+1,. r~ ~ *.,.. ' ~~:':' ~.l* . f?-* ~~- 37.0 ~ -~~ ~*- ~ * ~<' *. -_::;,.* :* ~ -~~ 1*- t> 38.0 --~ r~.
- ~. I
~ *- ='.... ~,. 1,-. ~ 39.0 ~ l~. ~-~. IT ~1~ t- ~ .... ~ *' i--"..:; ~?:~ I. 40.0 i: ~:]
- ~ -
' ~~. ~ w,,, r~ 'C ~
- 41.0 I~
N ~:to ~.... ~. 42.0 ~~ I"" t' ~. AMEC Project 6468-13-1072 I\\ 7 ~ -N164 34 Primary-structure Planar Bedding / ~ -N162 39 Primary-structure Planar Bedding 1-------- I\\ //// ~ -N151 40 Primary-structure Planar Bedding II /// ~ -N156 37 Primary-structure Planar Bedding MP-101 42.680 to 35.312f1 AMEC Clinch River SMR Project Borehole MP-1 01 Acoustic Televiewer Features rev 2 Sheet 4 of 72 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-623 of 1849 January 11, 2014 Page 621 of 1847 RCN: CRP-111 0.0 4
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project MP-101 50.048 to 42.680f1 AMEC Project 6468-13-1072 -N334 48 Fracture Planar Open-fracture -N160 31 Primary-structure Planar Bedding -N152 33 Primary-structure Planar Bedding -N148 33 Primary-structure Planar Bedding -N336 62 Fracture Discontinuous Hairline-fractun -N155 37 Primary-structure Planar Bedding -N159 34 Primary-structure Planar Bedding -N162 35 Primary-structure Planar Bedding 5 AMEC Clinch River SMR Project Borehole MP-1 01 Acoustic Televiewer Features rev 2 Sheet 5 of72 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-624 of 1849 January 11, 2014 Page 622 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc. Clinch River SMR Project ~- i ~.
- i.
r- ~-~ _.~:* ~*.
- ~~*
J -:~i,: .~-~ -.. 'I, ~* i" ";p.* ' ¥ -~. ~ * ~'. -- -~ I" Fe~ r-- 1-.
- -~
- 1.;*;*
~ i"~
- '1"
- I 1-
- -~
r,
- w AMEC Project 6468-13-1072 I'
/ ~ -N161 34 Primary-structure Planar Bedding II /7~/" ~ -N160 37 Primary-structure Planar Bedding I ~ / ~ -N165 35 Primary-structure Planar Bedding 1-------- I' / ~ -N158 34 Primary-structure Planar Bedding 7 I v -N168 38 Fracture Planar Open-fracture / ~ -N160 30 Primary-structure Planar Bedding I\\ ~ L_:_ ~ -N152 31 Primary-structure Planar Bedding / I ~ -N158 29 Primary-structure Planar Bedding j\\ MP-101 57.416 to 50.048f1 AMEC Clinch River SMR Project Borehole MP-1 01 Acoustic Televiewer Features rev 2 Sheet 6 of72 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 623 of 1847 RCN: CRP-111 0.0 Page C1-625 of 1849 6}}