Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-422 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 74.2 7660 14810 0.32 22.6 75.5 7330 13890 0.31 23.0 77.4 7370 12580 0.24 23.6 78.7 7660 14810 0.32 24.0 80.4 8330 16260 0.32 24.5 82.0 8330 16260 0.32 25.0 83.7 7710 13890 0.28 25.5 85.3 7370 13330 0.28 26.0 86.9 7450 13070 0.26 26.5 88.9 8080 15150 0.30 27.1 90.2 7840 14180 0.28 27.5 91.9 6700 14490 0.36 28.0 93.5 6170 12350 0.33 28.5 95.1 6260 12820 0.34 29.0 96.8 7530 13070 0.25 29.5 98.4 8770 16670 0.31 30.0 100.1 8080 16670 0.35 30.5 101.7 8080 14180 0.26 31.0 103.4 8130 14180 0.26 31.5 105.0 7170 13330 0.30 32.0 106.6 6730 15500 0.38 32.5 108.3 6770 13890 0.34 33.0 109.9 6730 12580 0.30 33.5 111.6 6500 12580 0.32 34.0 113.2 6840 12580 0.29 34.5 114.8 7620 13070 0.24 35.0 116.5 7450 13330 0.27 35.5 118.1 7370 13890 0.30 36.0 119.8 7580 13070 0.25 36.5 121.4 8230 15150 0.29 37.0 123.0 9320 17090 0.29 37.5 124.7 9320 16260 0.26 38.0 126.3 9070 16260 0.27 38.5 128.0 8330 15500 0.30 39.0 129.6 7940 13610 0.24 39.5 131.2 7450 13330 0.27 40.0 132.9 7290 13330 0.29 40.5 134.5 6980 13610 0.32 41.0 136.2 6800 13330 0.32 41.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-401 of 1849 Metric Units Velocity Vs (m/s) 2340 2230 2250 2340 2540 2540 2350 2250 2270 2460 2390 2040 1880 1910 2300 2670 2460 2460 2480 2180 2050 2060 2050 1980 2080 2320 2270 2250 2310 2510 2840 2840 2760 2540 2420 2270 2220 2130 2070 January 11, 2014 Poisson's Vo Ratio (m/s) 4520 0.32 4230 0.31 3830 0.24 4520 0.32 4960 0.32 4960 0.32 4230 0.28 4060 0.28 3980 0.26 4620 0.30 4320 0.28 4420 0.36 3760 0.33 3910 0.34 3980 0.25 5080 0.31 5080 0.35 4320 0.26 4320 0.26 4060 0.30 4730 0.38 4230 0.34 3830 0.30 3830 0.32 3830 0.29 3980 0.24 4060 0.27 4230 0.30 3980 0.25 4620 0.29 5210 0.29 4960 0.26 4960 0.27 4730 0.30 4150 0.24 4060 0.27 4060 0.29 4150 0.32 4060 0.32 Page 399 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-422 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 137.8 7410 14490 0.32 42.0 139.4 8180 15150 0.29 42.5 141.1 8330 15150 0.28 43.0 142.7 8440 14810 0.26 43.5 144.4 7750 14180 0.29 44.0 146.0 7410 14490 0.32 44.5 147.6 7090 12120 0.24 45.0 149.3 6600 12120 0.29 45.5 150.9 6840 11490 0.23 46.0 152.6 7130 13070 0.29 46.5 154.2 7620 13890 0.28 47.0 155.8 7580 12580 0.22 47.5 157.5 7450 13070 0.26 48.0 159.1 7370 12580 0.24 48.5 160.8 7170 13330 0.30 49.0 162.4 6800 12350 0.28 49.5 164.0 6540 12820 0.32 50.0 165.7 7020 13330 0.31 50.5 167.3 6170 11300 0.29 51.0 169.0 6230 11110 0.27 51.5 170.6 6380 11700 0.29 52.0 172.2 6320 13890 0.37 52.5 173.9 6800 11900 0.26 53.0 175.5 7450 12350 0.21 53.5 177.2 7290 15500 0.36 54.0 178.8 7750 12820 0.21 54.5 180.5 8130 16260 0.33 55.0 182.1 7490 12350 0.21 55.5 183.7 7940 13610 0.24 56.0 185.4 9460 18520 0.32 56.5 187.0 10180 20200 0.33 57.0 188.7 9660 18520 0.31 57.5 190.3 9320 18520 0.33 58.0 191.9 9520 18520 0.32 58.5 193.6 9730 18520 0.31 59.0 195.2 9880 19050 0.32 59.5 196.9 10340 20200 0.32 60.0 198.5 9590 18020 0.30 60.5 200.1 9130 15500 0.23 61.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-402 of 1849 Metric Units Velocity Vs (m/s) 2260 2490 2540 2570 2360 2260 2160 2010 2080 2170 2320 2310 2270 2250 2180 2070 1990 2140 1880 1900 1940 1930 2070 2270 2220 2360 2480 2280 2420 2880 3100 2940 2840 2900 2970 3010 3150 2920 2780 January 11, 2014 Poisson's Vo Ratio (m/s) 4420 0.32 4620 0.29 4620 0.28 4520 0.26 4320 0.29 4420 0.32 3690 0.24 3690 0.29 3500 0.23 3980 0.29 4230 0.28 3830 0.22 3980 0.26 3830 0.24 4060 0.30 3760 0.28 3910 0.32 4060 0.31 3440 0.29 3390 0.27 3560 0.29 4230 0.37 3630 0.26 3760 0.21 4730 0.36 3910 0.21 4960 0.33 3760 0.21 4150 0.24 5640 0.32 6160 0.33 5640 0.31 5640 0.33 5640 0.32 5640 0.31 5810 0.32 6160 0.32 5490 0.30 4730 0.23 Page 400 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-422 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 201.8 8330 16260 0.32 61.5 203.4 8180 15500 0.31 62.0 205.1 8330 14810 0.27 62.5 206.7 8390 15500 0.29 63.0 208.3 8890 16670 0.30 63.5 210.0 9200 15870 0.25 64.0 211.6 8390 14810 0.26 64.5 213.3 7940 14810 0.30 65.0 214.9 7890 14810 0.30 65.5 216.5 8180 14810 0.28 66.0 218.2 7290 13610 0.30 66.5 219.8 9660 16670 0.25 67.0 221.5 9520 17090 0.27 67.5 223.1 9460 16260 0.24 68.0 224.7 9260 15870 0.24 68.5 226.4 9070 16670 0.29 69.0 228.0 9200 16260 0.26 69.5 229.7 9260 17090 0.29 70.0 231.3 9260 15870 0.24 70.5 232.9 8890 14490 0.20 71.0 234.6 9010 15870 0.26 71.5 236.2 9070 15150 0.22 72.0 237.9 8950 15150 0.23 72.5 239.5 8710 15870 0.28 73.0 241.1 8390 15150 0.28 73.5 242.8 8330 14810 0.27 74.0 244.4 8550 14810 0.25 74.5 246.1 9260 14810 0.18 75.0 247.7 9460 17090 0.28 75.5 249.3 9320 16670 0.27 76.0 251.0 8770 15150 0.25 76.5 252.6 7620 14490 0.31 77.0 254.3 7450 13330 0.27 77.5 255.9 7580 13330 0.26 78.0 257.6 6840 12120 0.27 78.5 259.2 6910 13070 0.31 79.0 260.8 8130 14810 0.28 79.5 262.5 9800 19050 0.32 80.0 264.1 9320 17540 0.30 80.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-403 of 1849 Metric Units Velocity Vs (m/s) 2540 2490 2540 2560 2710 2800 2560 2420 2400 2490 2220 2940 2900 2880 2820 2760 2800 2820 2820 2710 2750 2760 2730 2660 2560 2540 2610 2820 2880 2840 2670 2320 2270 2310 2080 2110 2480 2990 2840 January 11, 2014 Poisson's Vo Ratio (m/s) 4960 0.32 4730 0.31 4520 0.27 4730 0.29 5080 0.30 4840 0.25 4520 0.26 4520 0.30 4520 0.30 4520 0.28 4150 0.30 5080 0.25 5210 0.27 4960 0.24 4840 0.24 5080 0.29 4960 0.26 5210 0.29 4840 0.24 4420 0.20 4840 0.26 4620 0.22 4620 0.23 4840 0.28 4620 0.28 4520 0.27 4520 0.25 4520 0.18 5210 0.28 5080 0.27 4620 0.25 4420 0.31 4060 0.27 4060 0.26 3690 0.27 3980 0.31 4520 0.28 5810 0.32 5350 0.30 Page 401 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-422 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 265.8 8830 14180 0.18 81.0 267.4 9070 15150 0.22 81.5 269.0 9730 16670 0.24 82.0 270.7 10030 18520 0.29 82.5 272.3 10420 17540 0.23 83.0 274.0 9950 17090 0.24 83.5 275.6 9590 18520 0.32 84.0 277.2 9390 18020 0.31 84.5 278.9 9260 17540 0.31 85.0 280.5 9390 16260 0.25 85.5 282.2 9590 17090 0.27 86.0 283.8 8890 17090 0.31 86.5 285.4 9070 18520 0.34 87.0 287.1 8710 17090 0.32 87.5 288.7 8770 18020 0.34 88.0 290.4 10180 20200 0.33 88.5 292.0 8490 18020 0.36 89.0 293.6 7580 13890 0.29 89.5 295.3 8950 15870 0.27 90.0 296.9 6440 14810 0.38 90.5 298.6 9730 18020 0.29 91.0 300.2 10030 17540 0.26 91.5 301.8 10100 21510 0.36 92.0 303.5 9460 18020 0.31 92.5 305.1 8550 18520 0.36 93.0 306.8 9200 17540 0.31 93.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-404 of 1849 Metric Units Velocity Vs (m/s) 2690 2760 2970 3060 3180 3030 2920 2860 2820 2860 2920 2710 2760 2660 2670 3100 2590 2310 2730 1960 2970 3060 3080 2880 2610 2800 January 11, 2014 Poisson's Vo Ratio (m/s) 4320 0.18 4620 0.22 5080 0.24 5640 0.29 5350 0.23 5210 0.24 5640 0.32 5490 0.31 5350 0.31 4960 0.25 5210 0.27 5210 0.31 5640 0.34 5210 0.32 5490 0.34 6160 0.33 5490 0.36 4230 0.29 4840 0.27 4520 0.38 5490 0.29 5350 0.26 6550 0.36 5490 0.31 5640 0.36 5350 0.31 Page 402 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Fluid Conductivity Nat. Gamma (CAL)


+--------! Depth Conductivity-Short Conductivity-Long Fluid Temperature Feet DegC 18 CPS 150 1 uS/em 1500

-1 0 mS/m 40 -20 mS/m 30 15 Nat. Gamma (DUIN)

Borehole Diameter CPS 150 INCH 10 Nat. Gamma (FTC)

API 150 MP-422 10

- *~=-~~~-


r--.. ---+---

---+------+---

t i=-------t_L 20 30 40

.-c-50 60

+-

)

)

---f

=~)=====12==.== __::::\\:. =___:j::_ d:o

)

L =::::t_ l=

70 80

~ ---- t::: __ ____+/- l====t-1

~ -


£

""""' iE I ~ ~

+

~ ""

l

~ -f-*

150 t~-

160 110

')

h t 1----:;:: -'-

~

1

~

120

-_ __!, ____ - ~~ --~-I__:; _ _j___

130

~ ---+ 1-

---+/-

140 -- -

f-I"""'F--I-f-+--+-l'"1- +--+--'rl-+---+-+--:;:........\\

\\.. __ -::

..... --r- ---t I-+

180

--:-=ff=--:-:

190

--+--

~-.~

I J" 200 14

--l=r-----J:._------=:::-I=-

T 210 -

(

l 220

~

230

-- J ____ J ____ ____f: ___.l-1 1-1-~~=-~

r+-1~~~

"""" ~ =-

_f

--t-===+/-F

+

f

~:-

~ ----

-T

--+ I==;

--+--

~

240

(

(

t t

==3=====~==

F =~= ~=-==f

'1

_1\\,_ ____ }-___ ___.i:_I __ ____E:

t t- ---lf"-+ - +- 1--- -

1--- -

11----'1+-1---\\-

1---+-

\\

~

-+

= 1====1========1===/,-:::::::j::::::

1--- -

Ji J i

Figure 96. Boring MP-422, Induction, Fluid Temperature/Conductivity, Natural Gamma and Caliper logs GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-405 of 1849 January 11, 2014 Page 403 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 51. Boring MP-422, Acoustic Televiewer Feature depth, dip azimuth, dip and description Depth Dip Structure Dip (feet) azimuth description 11.3 N133 43 Primary-structure Planar Bedding 12.3 N320 65 Fracture Discontinuous Hairline-fracture 12.6 N148 31 Primary-structure Planar Bedding 12.9 N304 68 Fracture Discontinuous Hairline-fracture 13.7 N155 28 Primary-structure Planar Bedding 14.6 N323 64 Fracture Discontinuous Hairline-fracture 15.6 N144 27 Fracture Planar Open-fracture 15.8 N317 59 Fracture Discontinuous Hairline-fracture 17.0 N126 27 Fracture Planar Open-fracture 17.7 N155 33 Primary-structure Planar Bedding 18.2 N126 38 Fracture Planar Hairline-fracture 18.5 N313 70 Fracture Discontinuous Hairline-fracture 19.1 N141 34 Fracture Planar Hairline-fracture 19.4 N125 35 Primary-structure Planar Bedding 19.6 N289 71 Fracture Discontinuous Hairline-fracture 19.8 N119 32 Primary-structure Planar Bedding 20.2 N123 35 Fracture Planar Hairline-fracture 20.5 N300 65 Fracture Planar Hairline-fracture 21.5 N146 32 Primary-structure Planar Bedding 22.3 N160 36 Primary-structure Planar Bedding 22.8 N161 34 Primary-structure Planar Bedding 24.0 N161 32 Primary-structure Planar Bedding 24.9 N152 35 Primary-structure Planar Bedding 25.0 N333 65 Fracture Discontinuous Hairline-fracture 25.6 N162 35 Primary-structure Planar Bedding 26.5 N152 35 Primary-structure Planar Bedding 27.3 N317 76 Fracture Irregular Hairline-fracture 27.7 N155 34 Primary-structure Planar Bedding 28.1 N318 56 Fracture Planar Hairline-fracture 28.5 N150 35 Primary-structure Planar Bedding 28.7 N152 30 Primary-structure Planar Bedding 29.8 N161 32 Primary-structure Planar Bedding 31.8 N160 36 Primary-structure Planar Bedding 33.4 N329 60 Fracture Discontinuous Hairline-fracture 33.6 N158 35 Primary-structure Planar Bedding 34.7 N153 34 Primary-structure Planar Bedding 35.7 N159 31 Fracture Planar Open-fracture GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-406 of 1849 Page 404 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 37.0 N160 36 Primary-structure Planar Bedding 38.1 N337 59 Fracture Discontinuous Hairline-fracture 38.2 N150 34 Primary-structure Planar Bedding 40.0 N157 32 Primary-structure Planar Bedding 40.4 N338 54 Fracture Discontinuous Hairline-fracture 41.0 N162 33 Primary-structure Planar Bedding 42.5 N159 38 Primary-structure Planar Bedding 42.5 N343 61 Fracture Discontinuous Hairline-fracture 43.2 N329 65 Fracture Discontinuous Hairline-fracture 43.6 N159 33 Primary-structure Planar Bedding 44.0 N332 54 Fracture Discontinuous Hairline-fracture 44.0 N151 36 Primary-structure Planar Bedding 44.5 N153 34 Primary-structure Planar Bedding 45.8 N158 34 Primary-structure Planar Bedding 46.5 N337 64 Fracture Discontinuous Hairline-fracture 46.6 N156 35 Primary-structure Planar Bedding 47.3 N030 43 Fracture Discontinuous Hairline-fracture 47.3 N156 31 Primary-structure Planar Bedding 48.0 N156 37 Primary-structure Planar Bedding 48.3 N144 33 Primary-structure Planar Bedding 49.3 N158 33 Primary-structure Planar Bedding 50.3 N153 30 Primary-structure Planar Bedding 50.7 N326 63 Fracture Discontinuous Hairline-fracture 51.0 N166 34 Primary-structure Planar Bedding 53.3 N162 35 Primary-structure Planar Bedding 53.8 N327 57 Fracture Discontinuous Hairline-fracture 54.2 N154 31 Primary-structure Planar Bedding 54.5 N154 35 Fracture Planar Open-fracture 55.8 N160 25 Primary-structure Planar Bedding 56.2 N160 34 Primary-structure Planar Bedding 58.4 N155 27 Primary-structure Planar Bedding 58.7 N155 36 Primary-structure Planar Bedding 59.6 N153 31 Primary-structure Planar Bedding 59.8 N349 43 Fracture Planar Hairline-fracture 60.3 N326 45 Fracture Planar Hairline-fracture 61.3 N156 31 Primary-structure Planar Bedding 62.3 N156 30 Primary-structure Planar Bedding 63.1 N159 34 Primary-structure Planar Bedding 63.9 N163 35 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-407 of 1849 Page 405 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 65.4 N161 35 Primary-structure Planar Bedding 65.8 N153 37 Primary-structure Planar Bedding 66.7 N156 30 Primary-structure Planar Bedding 67.7 N158 33 Primary-structure Planar Bedding 68.8 N162 32 Primary-structure Planar Bedding 70.2 N164 32 Primary-structure Planar Bedding 73.6 N160 35 Primary-structure Planar Bedding 73.6 N345 58 Fracture Discontinuous Hairline-fracture 75.1 N162 36 Primary-structure Planar Bedding 76.1 N157 34 Primary-structure Planar Bedding 76.6 N157 31 Primary-structure Planar Bedding 77.6 N157 38 Primary-structure Planar Bedding 79.3 N152 32 Primary-structure Planar Bedding 80.8 N155 33 Primary-structure Planar Bedding 81.2 N162 32 Primary-structure Planar Bedding 82.2 N338 55 Fracture Discontinuous Hairline-fracture 82.4 N161 32 Primary-structure Planar Bedding 84.2 N162 36 Primary-structure Planar Bedding 85.0 N332 48 Fracture Discontinuous Hairline-fracture 85.5 N156 34 Primary-structure Planar Bedding 85.7 N339 48 Fracture Discontinuous Hairline-fracture 86.0 N329 52 Fracture Discontinuous Hairline-fracture 86.7 N167 34 Primary-structure Planar Bedding 87.3 N159 34 Primary-structure Planar Bedding 88.1 N159 30 Primary-structure Planar Bedding 88.4 N161 35 Primary-structure Planar Bedding 89.0 N157 38 Primary-structure Planar Bedding 91.1 N152 30 Primary-structure Planar Bedding 91.6 N166 38 Primary-structure Planar Bedding 92.6 N163 27 Primary-structure Planar Bedding 93.5 N156 31 Primary-structure Planar Bedding 94.3 N158 34 Primary-structure Planar Bedding 95.9 N159 32 Primary-structure Planar Bedding 97.1 N154 32 Primary-structure Planar Bedding 100.7 N321 47 Fracture Planar Hairline-fracture 103.6 N162 32 Primary-structure Planar Bedding 104.4 N157 25 Primary-structure Planar Bedding 106.4 N171 32 Primary-structure Planar Bedding 106.7 N162 35 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-408 of 1849 Page 406 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 107.8 N169 27 Primary-structure Planar Bedding 108.4 N162 37 Primary-structure Planar Bedding 110.0 N166 29 Primary-structure Planar Bedding 111.3 N157 32 Primary-structure Planar Bedding 112.1 N157 30 Primary-structure Planar Bedding 113.0 N164 30 Primary-structure Planar Bedding 116.8 N156 31 Primary-structure Planar Bedding 120.9 N331 59 Fracture Irregular Hairline-fracture 121.5 N325 58 Fracture Planar Hairline-fracture 124.3 N159 31 Primary-structure Planar Bedding 127.3 N154 28 Primary-structure Planar Bedding 128.7 N159 29 Primary-structure Planar Bedding 130.6 N157 28 Primary-structure Planar Bedding 132.9 N160 33 Primary-structure Planar Bedding 134.0 N158 29 Primary-structure Planar Bedding 137.3 N161 36 Primary-structure Planar Bedding 137.9 N155 35 Primary-structure Planar Bedding 138.5 N155 31 Primary-structure Planar Bedding 139.5 N157 31 Primary-structure Planar Bedding 140.8 N157 28 Primary-structure Planar Bedding 142.0 N167 28 Primary-structure Planar Bedding 144.4 N151 31 Primary-structure Planar Bedding 145.3 N153 32 Primary-structure Planar Bedding 145.5 N160 35 Primary-structure Planar Bedding 146.7 N153 32 Primary-structure Planar Bedding 147.4 N151 30 Primary-structure Planar Bedding 149.1 N149 27 Primary-structure Planar Bedding 151.8 N167 29 Primary-structure Planar Bedding 153.7 N145 33 Primary-structure Planar Bedding 155.1 N153 32 Primary-structure Planar Bedding 156.6 N328 55 Fracture Discontinuous Hairline-fracture 157.5 N149 30 Primary-structure Planar Bedding 159.5 N319 61 Fracture Discontinuous Hairline-fracture 159.8 N143 30 Primary-structure Planar Bedding 160.1 N160 29 Primary-structure Planar Bedding 161.5 N150 33 Primary-structure Planar Bedding 163.0 N152 29 Primary-structure Planar Bedding 166.6 N156 31 Primary-structure Planar Bedding 169.1 N153 30 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-409 of 1849 Page 407 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 170.4 N143 34 Primary-structure Planar Bedding 171.7 N333 64 Fracture Discontinuous Hairline-fracture 172.0 N154 33 Primary-structure Planar Bedding 173.1 N164 36 Primary-structure Planar Bedding 173.7 N151 36 Fracture Planar Open-fracture 176.1 N155 30 Primary-structure Planar Bedding 177.6 N155 34 Primary-structure Planar Bedding 180.4 N158 34 Primary-structure Planar Bedding 182.0 N158 32 Primary-structure Planar Bedding 183.2 N170 33 Primary-structure Planar Bedding 184.0 N164 35 Primary-structure Planar Bedding 186.0 N335 62 Fracture Discontinuous Hairline-fracture 186.6 N173 34 Primary-structure Planar Bedding 186.7 N347 51 Fracture Discontinuous Hairline-fracture 187.3 N166 42 Primary-structure Planar Bedding 187.8 N162 34 Primary-structure Planar Bedding 191.0 N319 49 Fracture Discontinuous Hairline-fracture 191.4 N336 56 Fracture Discontinuous Hairline-fracture 191.6 N148 29 Primary-structure Planar Bedding 192.6 N163 37 Primary-structure Planar Bedding 192.8 N334 53 Fracture Discontinuous Hairline-fracture 194.2 N334 51 Fracture Discontinuous Hairline-fracture 194.3 N162 33 Primary-structure Planar Bedding 195.3 N153 33 Primary-structure Planar Bedding 196.1 N157 41 Primary-structure Planar Bedding 197.7 N164 36 Primary-structure Planar Bedding 199.0 N162 34 Primary-structure Planar Bedding 200.2 N162 36 Primary-structure Planar Bedding 200.4 N332 57 Fracture Discontinuous Hairline-fracture 201.8 N148 34 Primary-structure Planar Bedding 203.8 N162 30 Primary-structure Planar Bedding 204.7 N159 38 Primary-structure Planar Bedding 205.4 N157 37 Primary-structure Planar Bedding 206.3 N157 36 Primary-structure Planar Bedding 211.8 N152 35 Primary-structure Planar Bedding 216.3 N162 34 Primary-structure Planar Bedding 218.4 N156 32 Primary-structure Planar Bedding 221.4 N155 35 Primary-structure Planar Bedding 226.7 N170 27 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-410 of 1849 Page 408 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 227.3 N154 32 Primary-structure Planar Bedding 228.5 N338 64 Fracture Discontinuous Hairline-fracture 229.2 N331 60 Fracture Discontinuous Hairline-fracture 230.2 N164 38 Primary-structure Planar Bedding 231.3 N141 31 Primary-structure Planar Bedding 232.1 N157 34 Primary-structure Planar Bedding 234.6 N153 30 Primary-structure Planar Bedding 234.8 N327 55 Fracture Discontinuous Hairline-fracture 235.8 N167 28 Primary-structure Planar Bedding 236.3 N335 51 Fracture Discontinuous Hairline-fracture 238.0 N160 30 Primary-structure Planar Bedding 241.1 N145 33 Primary-structure Planar Bedding 242.4 N154 31 Primary-structure Planar Bedding 242.6 N151 30 Primary-structure Planar Bedding 244.1 N143 25 Primary-structure Planar Bedding 244.7 N149 30 Primary-structure Planar Bedding 245.2 N154 32 Primary-structure Planar Bedding 246.0 N337 39 Fracture Discontinuous Hairline-fracture 246.7 N346 56 Fracture Discontinuous Hairline-fracture 246.9 N334 63 Fracture Discontinuous Hairline-fracture 247.0 N153 32 Primary-structure Planar Bedding 247.9 N149 32 Primary-structure Planar Bedding 248.5 N151 32 Primary-structure Planar Bedding 250.1 N157 25 Primary-structure Planar Bedding 251.8 N152 32 Primary-structure Planar Bedding 252.7 N151 31 Primary-structure Planar Bedding 257.0 N152 27 Primary-structure Planar Bedding 260.3 N150 29 Primary-structure Planar Bedding 261.6 N153 33 Primary-structure Planar Bedding 263.0 N335 68 Fracture Discontinuous Hairline-fracture 263.2 N133 31 Primary-structure Planar Bedding 270.3 N175 42 Primary-structure Irregular Bedding 272.2 N145 36 Primary-structure Planar Bedding 273.7 N333 57 Fracture Discontinuous Hairline-fracture 277.2 N145 73 Fracture Discontinuous Hairline-fracture 284.5 N143 38 Primary-structure Planar Bedding 285.6 N332 61 Fracture Discontinuous Hairline-fracture 285.8 N170 31 Primary-structure Planar Bedding 286.4 N160 31 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-411 of 1849 Page 409 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 287.1 N167 29 Primary-structure Planar Bedding 288.6 N140 32 Primary-structure Planar Bedding 288.8 N356 56 Fracture Discontinuous Hairline-fracture 289.8 N160 30 Primary-structure Planar Bedding 290.4 N180 77 Fracture Irregular Hairline-fracture 291.1 N162 30 Primary-structure Planar Bedding 291.8 N161 29 Primary-structure Planar Bedding 292.4 N158 43 Primary-structure Planar Bedding 292.8 N153 35 Primary-structure Planar Bedding 293.4 N157 28 Primary-structure Planar Bedding 293.5 N293 67 Fracture Discontinuous Hairline-fracture 293.9 N150 22 Primary-structure Planar Bedding 294.3 N260 41 Fracture Discontinuous Hairline-fracture 294.6 N202 34 Primary-structure Planar Bedding 295.3 N167 32 Fracture Planar Open-fracture 295.7 N145 43 Primary-structure Planar Bedding 296.5 N166 30 Primary-structure Planar Bedding 296.8 N355 60 Fracture Discontinuous Hairline-fracture 298.9 N156 41 Primary-structure Planar Bedding 300.0 N161 55 Primary-structure Planar Bedding 300.4 N162 35 Primary-structure Planar Bedding 304.8 N153 41 Primary-structure Planar Bedding 307.9 N141 43 Primary-structure Planar Bedding 309.6 N150 40 Primary-structure Planar Bedding 309.9 N005 58 Fracture Discontinuous Hairline-fracture 310.9 N166 36 Primary-structure Planar Bedding 311.9 N154 33 Primary-structure Planar Bedding 313.4 N173 54 Fracture Planar Hairline-fracture 313.7 N148 62 Fracture Planar Hairline-fracture 314.0 N154 35 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-412 of 1849 Page 410 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC CLINCH RIVER top of borehole...

East:

Nortll Alt:

Zone from 314.486 to 10.788ft Interpretation 1 Dip data sets..

BHTVdips MP-422 10.788-314.486ft Dip-azimuth, fracture rose-diagram DIP DATA INTERPRETATION RGLDIP vsn 6.2 DIP-AZIMUTH. FRACTURE ROSE-DIAGRAM w

Borehole: MP-422 Azimuth I ncr= 10° N ~ 262 MP-422, Interpretation 1 314.486 to 10.788fl North ref. is true Depth units are feet N

s AMEC Project 6468-13-1072 E

0 1 0 20 30 40 50 60 70 80 90 1 00 Figure 97. Boring MP-422, Rose Diagram GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-413 of 1849 January 11, 2014 Page 411 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N44 Borehole: MP-422 Sonde: BHTV Zone from: 0.000 to 318.885ft North ref is true Mean deviation: 1.32 to N313_61 End coordinates.

North: 5_050 East: -5.302 Down: 318.777 Azimuth of end: N313.61 Distance start-end: 7.322ft Viewpoint: N44 Data extrapolated to the surface from 1 0.453ft 100 200 300-Figure 98. Boring MP-422, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-414 of 1849 January 11, 2014 Page 412 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 CLINCH RIVER SMR PROJECT BOREHOLE MP-423 Receiver to Receiver V5 and V P Analysis 0

~ Near-Far Receivers, Vs r--

f--

20 Near-Far Receivers, Vp f--

r--

40 1- -

411 60 t..,.

~

!!!!"=:;:;..

~

80 1-rc::;;;.;

......,.;;:..ii HI 100 I.

~

~ -

-=

120

~

11:1

~

- 140

.... 11

... __;tl I -=iii -*

c 1-160 a..

"..... -- !::e.

w c

180

i..

... ~

!==-

w:JP

~ =--

~ ~

200

~

  • :r - L
  • ~
II
!!>II 220

""'-iii re::~

...==-

240

.... ~

-a:..

260

~

1- --..._

280

... Fe-

...... F-

~

~-"= *

--==....

IE 1...

I 300

~ r--.

320 0

5000 10000 15000 20000 25000 VELOCITY (ft/s)

Figure 99: Boring MP-423, Suspension R1-R2 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-415 of 1849 January 11, 2014 Page 413 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 52. Boring MP-423, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-423 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 47.6 7940 13330 0.23 14.5 49.2 7840 14490 0.29 15.0 50.9 7020 12820 0.29 15.5 52.5 6800 15500 0.38 16.0 54.1 7020 15150 0.36 16.5 55.8 6870 14810 0.36 17.0 57.4 7090 14180 0.33 17.5 59.1 7580 14490 0.31 18.0 60.7 7530 14490 0.31 18.5 62.3 7840 14810 0.31 19.0 64.0 8030 16260 0.34 19.5 65.6 7620 15500 0.34 20.0 67.3 7330 14180 0.32 20.5 68.9 6670 15150 0.38 21.0 70.5 6910 14180 0.34 21.5 72.2 7330 14490 0.33 22.0 73.8 7710 13890 0.28 22.5 75.5 7750 13330 0.24 23.0 77.1 8280 13890 0.22 23.5 78.7 8830 14810 0.22 24.0 80.4 9320 18520 0.33 24.5 82.0 9010 16670 0.29 25.0 83.7 7660 15500 0.34 25.5 85.3 10030 19610 0.32 26.0 86.9 8890 18020 0.34 26.5 88.6 10100 19610 0.32 27.0 90.2 10260 16670 0.20 27.5 91.9 8440 16670 0.33 28.0 93.5 9390 17540 0.30 28.5 95.1 9520 19050 0.33 29.0 96.8 9460 18520 0.32 29.5 98.4 9320 17540 0.30 30.0 100.1 9660 17090 0.27 30.5 101.7 10030 19610 0.32 31.0 103.4 9730 18020 0.29 31.5 105.0 9730 16670 0.24 32.0 106.6 9800 17540 0.27 32.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-416 of 1849 Metric Units Velocity Vs (m/s) 2420 2390 2140 2070 2140 2090 2160 2310 2300 2390 2450 2320 2230 2030 2110 2230 2350 2360 2520 2690 2840 2750 2340 3060 2710 3080 3130 2570 2860 2900 2880 2840 2940 3060 2970 2970 2990 January 11, 2014 Poisson's Vo Ratio (m/s) 4060 0.23 4420 0.29 3910 0.29 4730 0.38 4620 0.36 4520 0.36 4320 0.33 4420 0.31 4420 0.31 4520 0.31 4960 0.34 4730 0.34 4320 0.32 4620 0.38 4320 0.34 4420 0.33 4230 0.28 4060 0.24 4230 0.22 4520 0.22 5640 0.33 5080 0.29 4730 0.34 5980 0.32 5490 0.34 5980 0.32 5080 0.20 5080 0.33 5350 0.30 5810 0.33 5640 0.32 5350 0.30 5210 0.27 5980 0.32 5490 0.29 5080 0.24 5350 0.27 Page 414 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-423 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 108.3 9520 16260 0.24 33.0 109.9 9200 17090 0.30 33.5 111.6 9130 16670 0.29 34.0 113.2 10030 16670 0.22 34.5 114.8 10750 19050 0.27 35.0 116.5 10930 19610 0.27 35.5 118.1 10100 19050 0.30 36.0 119.8 9460 17540 0.30 36.5 121.4 9950 19610 0.33 37.0 123.0 10420 19610 0.30 37.5 124.7 10340 20200 0.32 38.0 126.3 9730 18020 0.29 38.5 128.0 9660 17540 0.28 39.0 129.6 9660 18020 0.30 39.5 131.2 7710 15500 0.34 40.0 132.9 7410 14490 0.32 40.5 134.5 8080 14490 0.27 41.0 136.2 8280 14490 0.26 41.5 137.8 7800 15500 0.33 42.0 139.4 7620 15500 0.34 42.5 141.1 8950 17090 0.31 43.0 142.7 8830 16260 0.29 43.5 144.4 7800 15150 0.32 44.0 146.0 7330 13330 0.28 44.5 147.6 7410 13890 0.30 45.0 149.3 7410 14490 0.32 45.5 150.9 7490 14810 0.33 46.0 152.6 7660 14180 0.29 46.5 154.2 8130 17090 0.35 47.0 155.8 8490 17090 0.34 47.5 157.5 8440 14810 0.26 48.0 159.1 8080 17090 0.36 48.5 160.8 8600 16260 0.31 49.0 162.4 9460 16670 0.26 49.5 164.0 9730 18020 0.29 50.0 165.7 9130 17090 0.30 50.5 167.3 7130 14810 0.35 51.0 169.0 7050 15150 0.36 51.5 170.6 7750 14490 0.30 52.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-417 of 1849 Metric Units Velocity Vs (m/s) 2900 2800 2780 3060 3280 3330 3080 2880 3030 3180 3150 2970 2940 2940 2350 2260 2460 2520 2380 2320 2730 2690 2380 2230 2260 2260 2280 2340 2480 2590 2570 2460 2620 2880 2970 2780 2170 2150 2360 January 11, 2014 Poisson's Vo Ratio (m/s) 4960 0.24 5210 0.30 5080 0.29 5080 0.22 5810 0.27 5980 0.27 5810 0.30 5350 0.30 5980 0.33 5980 0.30 6160 0.32 5490 0.29 5350 0.28 5490 0.30 4730 0.34 4420 0.32 4420 0.27 4420 0.26 4730 0.33 4730 0.34 5210 0.31 4960 0.29 4620 0.32 4060 0.28 4230 0.30 4420 0.32 4520 0.33 4320 0.29 5210 0.35 5210 0.34 4520 0.26 5210 0.36 4960 0.31 5080 0.26 5490 0.29 5210 0.30 4520 0.35 4620 0.36 4420 0.30 Page 415 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-423 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 172.2 8390 14810 0.26 52.5 173.9 8830 15870 0.28 53.0 175.5 7980 14490 0.28 53.5 177.2 8230 15150 0.29 54.0 178.8 8080 14490 0.27 54.5 180.5 7170 14180 0.33 55.0 182.1 6940 14180 0.34 55.5 183.7 7210 13890 0.32 56.0 185.4 7490 14490 0.32 56.5 187.0 8030 15870 0.33 57.0 188.7 7940 15500 0.32 57.5 190.3 7660 15150 0.33 58.0 191.9 8440 16670 0.33 58.5 193.6 9260 18020 0.32 59.0 195.2 8830 16670 0.30 59.5 196.9 8030 16260 0.34 60.0 198.5 7840 15150 0.32 60.5 200.1 8030 16260 0.34 61.0 201.8 7370 13890 0.30 61.5 203.4 6770 13890 0.34 62.0 205.1 7330 14180 0.32 62.5 206.7 8080 15870 0.33 63.0 208.3 8030 14810 0.29 63.5 210.0 8280 14810 0.27 64.0 211.6 8770 16260 0.29 64.5 213.3 8770 16670 0.31 65.0 214.9 7890 14810 0.30 65.5 216.5 7530 13890 0.29 66.0 218.2 7800 14810 0.31 66.5 219.8 8710 15150 0.25 67.0 221.5 7750 14810 0.31 67.5 223.1 7750 14810 0.31 68.0 224.7 9130 15500 0.23 68.5 226.4 9800 19050 0.32 69.0 228.0 9320 17540 0.30 69.5 229.7 9800 18520 0.31 70.0 231.3 9660 18520 0.31 70.5 232.9 9130 16260 0.27 71.0 234.6 8280 16260 0.32 71.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-418 of 1849 Metric Units Velocity Vs (m/s) 2560 2690 2430 2510 2460 2180 2120 2200 2280 2450 2420 2340 2570 2820 2690 2450 2390 2450 2250 2060 2230 2460 2450 2520 2670 2670 2400 2300 2380 2660 2360 2360 2780 2990 2840 2990 2940 2780 2520 January 11, 2014 Poisson's Vo Ratio (m/s) 4520 0.26 4840 0.28 4420 0.28 4620 0.29 4420 0.27 4320 0.33 4320 0.34 4230 0.32 4420 0.32 4840 0.33 4730 0.32 4620 0.33 5080 0.33 5490 0.32 5080 0.30 4960 0.34 4620 0.32 4960 0.34 4230 0.30 4230 0.34 4320 0.32 4840 0.33 4520 0.29 4520 0.27 4960 0.29 5080 0.31 4520 0.30 4230 0.29 4520 0.31 4620 0.25 4520 0.31 4520 0.31 4730 0.23 5810 0.32 5350 0.30 5640 0.31 5640 0.31 4960 0.27 4960 0.32 Page 416 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-423 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 236.2 8280 16260 0.32 72.0 237.9 8830 16670 0.30 72.5 239.5 7710 14490 0.30 73.0 241.1 7050 13610 0.32 73.5 242.8 7410 14180 0.31 74.0 244.4 8230 14810 0.28 74.5 246.1 8830 15500 0.26 75.0 247.7 8280 18020 0.37 75.5 249.3 8440 15870 0.30 76.0 251.0 7840 14810 0.31 76.5 252.6 9730 17540 0.28 77.0 254.3 9660 18020 0.30 77.5 255.9 8770 15870 0.28 78.0 257.6 8130 15150 0.30 78.5 259.2 6670 13330 0.33 79.0 260.8 6800 13890 0.34 79.5 262.5 9260 18520 0.33 80.0 264.1 8830 17540 0.33 80.5 265.8 9320 17090 0.29 81.0 267.4 10100 18020 0.27 81.5 269.0 10100 17090 0.23 82.0 270.7 9660 17090 0.27 82.5 272.3 10340 17540 0.23 83.0 274.0 11110 19050 0.24 83.5 275.6 11800 21510 0.28 84.0 277.2 11300 20830 0.29 84.5 278.9 10500 20200 0.32 85.0 280.5 10840 20200 0.30 85.5 282.2 11300 20830 0.29 86.0 283.8 12010 22220 0.29 86.5 285.4 11300 21510 0.31 87.0 287.1 10420 19610 0.30 87.5 288.7 11200 19610 0.26 88.0 290.4 11590 20830 0.28 88.5 292.0 11700 20830 0.27 89.0 293.6 11300 20830 0.29 89.5 295.3 12820 21510 0.22 90.0 296.9 11800 22220 0.30 90.5 298.6 8600 17090 0.33 91.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-419 of 1849 Metric Units Velocity Vs (m/s) 2520 2690 2350 2150 2260 2510 2690 2520 2570 2390 2970 2940 2670 2480 2030 2070 2820 2690 2840 3080 3080 2940 3150 3390 3600 3440 3200 3300 3440 3660 3440 3180 3420 3530 3560 3440 3910 3600 2620 January 11, 2014 Poisson's Vo Ratio (m/s) 4960 0.32 5080 0.30 4420 0.30 4150 0.32 4320 0.31 4520 0.28 4730 0.26 5490 0.37 4840 0.30 4520 0.31 5350 0.28 5490 0.30 4840 0.28 4620 0.30 4060 0.33 4230 0.34 5640 0.33 5350 0.33 5210 0.29 5490 0.27 5210 0.23 5210 0.27 5350 0.23 5810 0.24 6550 0.28 6350 0.29 6160 0.32 6160 0.30 6350 0.29 6770 0.29 6550 0.31 5980 0.30 5980 0.26 6350 0.28 6350 0.27 6350 0.29 6550 0.22 6770 0.30 5210 0.33 Page 417 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-423 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 300.2 7980 18020 0.38 91.5 301.8 11110 20830 0.30 92.0 303.5 10930 21510 0.33 92.5 305.1 11400 21510 0.30 93.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-420 of 1849 Metric Units Velocity Vs (m/s) 2430 3390 3330 3470 January 11, 2014 Poisson's Vo Ratio (m/s) 5490 0.38 6350 0.30 6550 0.33 6550 0.30 Page 418 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Nat. Gamma (CAL)

Fluid Conductivity Conductivity-Short Conductivity-Long Borehole Diameter Depth 0

CPS 150 200 uS/em 600

-10 mS/m 30 -20 mS/m 20 2 INCH 6

Feet Nat. Gamma (DUIN)

Conductivity-Short#2 Conductivity-Long#2 Fluid Temperature 0

CPS 150

-10 mS/m 30 -20 mS/m 20 14 DegC 18 Nat. Gamma (FTC) 0 CPS 150 MP-423

~

10

.,J~

20 llil

~

-~

30 40

~> 1>"

_r

./

  • ~

50 J

}

r

~

)

60

.,.2-70

-d:,

--f

)

80 rr

I

\\.

~

90

~f"

(

1~

100 li 110 I

~

120 G~

P' 130

~

~

~

140

b.

~

!="

150

~

?

1 160

-""" ~

~ I=

~

~

170

.It c

180

~

'~*

190

~

l

<§I ~

/

\\

~ -

200 p

/

= 9 210

.!~

~-

220 s r-r r

230

~ ~~

240

"":t t>

~>

<=$ ~

250 c::;

~

§

£. ~

{.,

~-

260

?

v 270 280

~

-~

1\\

290 l

300

.;t:..

310

- ~

Figure 100. Boring MP-423, Induction, Fluid Temperature/Conductivity, Natural Gamma and Caliper logs GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1421 of 1849 January 11, 2014 Page 419 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 53. Boring MP-423, Acoustic Televiewer Feature depth, dip azimuth, dip and description Depth Dip Structure Dip (feet) azimuth description 46.2 N147 36 Primary-structure Planar Bedding 46.8 N135 39 Primary-structure Planar Bedding 47.4 N139 39 Primary-structure Planar Bedding 48.0 N138 39 Primary-structure Planar Bedding 48.9 N142 35 Primary-structure Planar Bedding 49.3 N147 34 Primary-structure Planar Bedding 49.7 N314 52 Fracture Planar Hairline-fracture 51.2 N149 38 Primary-structure Planar Bedding 52.2 N143 45 Primary-structure Planar Bedding 52.7 N316 40 Fracture Discontinuous Hairline-fracture 53.3 N144 35 Primary-structure Planar Bedding 54.2 N155 35 Primary-structure Planar Bedding 54.7 N331 53 Fracture Discontinuous Hairline-fracture 55.1 N152 36 Primary-structure Planar Bedding 55.7 N158 36 Primary-structure Planar Bedding 56.0 N152 33 Primary-structure Planar Bedding 56.7 N153 36 Primary-structure Planar Bedding 56.9 N329 45 Fracture Discontinuous Hairline-fracture 57.4 N313 49 Fracture Discontinuous Hairline-fracture 57.5 N167 32 Primary-structure Planar Bedding 58.2 N147 36 Primary-structure Planar Bedding 58.6 N149 37 Primary-structure Planar Bedding 59.5 N148 34 Primary-structure Planar Bedding 61.1 N154 38 Primary-structure Planar Bedding 62.1 N157 35 Primary-structure Planar Bedding 63.9 N156 44 Primary-structure Planar Bedding 64.9 N157 31 Primary-structure Planar Bedding 66.0 N150 38 Primary-structure Planar Bedding 66.3 N160 41 Primary-structure Planar Bedding 67.1 N172 41 Primary-structure Planar Bedding 67.8 N166 37 Primary-structure Planar Bedding 68.1 N154 36 Primary-structure Planar Bedding 68.7 N143 39 Primary-structure Planar Bedding 69.1 N159 40 Primary-structure Planar Bedding 69.6 N331 59 Fracture Discontinuous Hairline-fracture 70.0 N152 41 Primary-structure Planar Bedding 70.2 N330 37 Fracture Planar Hairline-fracture GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-422 of 1849 Page 420 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 70.8 N151 38 Primary-structure Planar Bedding 71.1 N151 38 Primary-structure Planar Bedding 71.8 N155 38 Primary-structure Planar Bedding 72.5 N156 36 Primary-structure Planar Bedding 73.5 N154 35 Primary-structure Planar Bedding 74.4 N157 34 Primary-structure Planar Bedding 74.8 N155 36 Primary-structure Planar Bedding 75.4 N329 48 Fracture Planar Hairline-fracture 75.6 N153 34 Primary-structure Planar Bedding 77.2 N158 36 Primary-structure Planar Bedding 78.8 N161 35 Primary-structure Planar Bedding 79.3 N311 71 Fracture Discontinuous Hairline-fracture 79.7 N151 33 Primary-structure Planar Bedding 82.3 N155 30 Primary-structure Planar Bedding 83.0 N154 35 Primary-structure Planar Bedding 83.8 N157 35 Primary-structure Planar Bedding 84.4 N136 33 Fracture Planar Open-fracture 85.0 N149 35 Primary-structure Planar Bedding 86.3 N153 39 Primary-structure Planar Bedding 87.1 N318 20 Fracture Planar Open-fracture 89.6 N332 28 Fracture Discontinuous Hairline-fracture 89.7 N148 42 Primary-structure Planar Bedding 89.9 N346 33 Fracture Planar Open-fracture 90.5 N154 43 Primary-structure Planar Bedding 91.2 N155 49 Primary-structure Planar Bedding 91.7 N346 6

Fracture Planar Open-fracture 92.2 N325 78 Fracture Irregular Hairline-fracture 92.4 N160 37 Primary-structure Planar Bedding 93.3 N165 42 Primary-structure Planar Bedding 93.7 N328 62 Fracture Discontinuous Hairline-fracture 94.5 N152 34 Primary-structure Planar Bedding 95.1 N148 40 Primary-structure Planar Bedding 95.7 N156 38 Primary-structure Planar Bedding 96.9 N159 37 Primary-structure Planar Bedding 98.3 N146 74 Fracture Discontinuous Hairline-fracture 98.4 N151 39 Primary-structure Planar Bedding 98.7 N125 72 Fracture Discontinuous Hairline-fracture 100.6 N351 71 Fracture Discontinuous Hairline-fracture 101.5 N139 36 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-423 of 1849 Page 421 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 102.0 N144 39 Primary-structure Planar Bedding 102.2 N141 37 Primary-structure Planar Bedding 102.9 N161 32 Primary-structure Planar Bedding 103.1 N333 65 Fracture Discontinuous Hairline-fracture 104.6 N325 50 Fracture Discontinuous Hairline-fracture 105.9 N148 32 Primary-structure Planar Bedding 106.3 N147 30 Primary-structure Planar Bedding 107.1 N151 31 Primary-structure Planar Bedding 107.8 N163 35 Primary-structure Planar Bedding 110.0 N153 33 Primary-structure Planar Bedding 111.7 N151 36 Primary-structure Planar Bedding 112.3 N163 36 Primary-structure Planar Bedding 113.1 N141 30 Primary-structure Planar Bedding 114.1 N146 35 Primary-structure Planar Bedding 114.9 N155 30 Primary-structure Planar Bedding 115.5 N334 54 Fracture Planar Hairline-fracture 116.0 N148 32 Primary-structure Planar Bedding 117.4 N162 27 Primary-structure Planar Bedding 117.8 N332 49 Fracture Planar Hairline-fracture 118.8 N148 38 Primary-structure Planar Bedding 119.3 N321 45 Fracture Planar Hairline-fracture 119.6 N328 38 Fracture Planar Hairline-fracture 119.7 N146 33 Primary-structure Planar Bedding 121.1 N153 37 Primary-structure Planar Bedding 122.8 N147 59 Fracture Discontinuous Hairline-fracture 123.4 N304 53 Fracture Irregular Hairline-fracture 123.9 N155 30 Primary-structure Planar Bedding 124.1 N166 35 Primary-structure Planar Bedding 124.4 N328 51 Fracture Planar Hairline-fracture 126.4 N153 35 Primary-structure Planar Bedding 131.5 N174 36 Primary-structure Planar Bedding 132.0 N153 38 Primary-structure Planar Bedding 132.9 N157 33 Primary-structure Planar Bedding 134.1 N154 37 Primary-structure Planar Bedding 136.2 N153 33 Primary-structure Planar Bedding 137.7 N157 37 Primary-structure Planar Bedding 139.1 N159 34 Primary-structure Planar Bedding 140.1 N160 37 Primary-structure Planar Bedding 141.0 N163 39 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-424 of 1849 Page 422 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 141.8 N144 31 Primary-structure Planar Bedding 142.6 N153 38 Primary-structure Planar Bedding 143.3 N159 36 Primary-structure Planar Bedding 143.4 N320 35 Fracture Discontinuous Hairline-fracture 144.4 N158 33 Primary-structure Planar Bedding 145.7 N156 38 Primary-structure Planar Bedding 153.7 N152 33 Primary-structure Planar Bedding 154.3 N153 37 Primary-structure Planar Bedding 155.7 N157 36 Primary-structure Planar Bedding 157.8 N159 36 Primary-structure Planar Bedding 158.9 N165 31 Primary-structure Planar Bedding 160.0 N156 34 Primary-structure Planar Bedding 161.0 N152 32 Primary-structure Planar Bedding 163.1 N157 33 Primary-structure Planar Bedding 165.8 N164 35 Primary-structure Planar Bedding 168.1 N179 41 Primary-structure Planar Bedding 169.4 N157 40 Primary-structure Planar Bedding 170.5 N158 33 Primary-structure Planar Bedding 172.0 N161 34 Primary-structure Planar Bedding 172.9 N160 36 Primary-structure Planar Bedding 173.8 N161 36 Primary-structure Planar Bedding 175.7 N157 35 Primary-structure Planar Bedding 177.0 N159 34 Primary-structure Planar Bedding 178.3 N159 34 Primary-structure Planar Bedding 181.0 N178 28 Primary-structure Planar Bedding 183.3 N160 36 Primary-structure Planar Bedding 184.1 N160 36 Primary-structure Planar Bedding 187.7 N157 30 Primary-structure Planar Bedding 189.3 N161 31 Primary-structure Planar Bedding 191.6 N162 35 Primary-structure Planar Bedding 192.7 N160 32 Primary-structure Planar Bedding 192.7 N336 52 Fracture Discontinuous Hairline-fracture 195.3 N160 36 Primary-structure Planar Bedding 197.5 N157 31 Primary-structure Planar Bedding 197.9 N158 33 Primary-structure Planar Bedding 198.3 N155 31 Primary-structure Planar Bedding 199.2 N160 31 Primary-structure Planar Bedding 199.5 N155 30 Primary-structure Planar Bedding 203.6 N178 32 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-425 of 1849 Page 423 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 205.2 N158 31 Primary-structure Planar Bedding 205.6 N153 31 Primary-structure Planar Bedding 206.3 N321 62 Fracture Planar Hairline-fracture 206.8 N163 28 Primary-structure Planar Bedding 207.4 N161 28 Primary-structure Planar Bedding 210.7 N157 32 Primary-structure Planar Bedding 211.2 N161 31 Primary-structure Planar Bedding 215.1 N155 31 Primary-structure Planar Bedding 216.1 N160 34 Primary-structure Planar Bedding 217.0 N159 28 Primary-structure Planar Bedding 218.3 N155 30 Primary-structure Planar Bedding 221.6 N170 41 Primary-structure Planar Bedding 222.3 N152 51 Primary-structure Planar Bedding 222.5 N151 51 Primary-structure Planar Bedding 223.0 N161 31 Primary-structure Planar Bedding 224.8 N166 30 Primary-structure Planar Bedding 226.5 N159 30 Primary-structure Planar Bedding 227.1 N328 60 Fracture Discontinuous Hairline-fracture 227.4 N157 28 Primary-structure Planar Bedding 229.4 N161 30 Primary-structure Planar Bedding 229.5 N320 49 Fracture Discontinuous Hairline-fracture 230.1 N170 36 Primary-structure Planar Bedding 231.0 N167 32 Primary-structure Planar Bedding 231.9 N164 31 Primary-structure Planar Bedding 234.4 N164 34 Primary-structure Planar Bedding 235.3 N147 35 Primary-structure Planar Bedding 237.0 N164 36 Primary-structure Planar Bedding 237.0 N349 63 Fracture Irregular Hairline-fracture 238.0 N318 51 Fracture Planar Hairline-fracture 239.5 N161 30 Primary-structure Planar Bedding 241.6 N331 64 Fracture Planar Hairline-fracture 242.9 N148 36 Primary-structure Planar Bedding 243.8 N155 31 Primary-structure Planar Bedding 244.0 N156 29 Primary-structure Planar Bedding 244.4 N165 30 Primary-structure Planar Bedding 245.3 N133 46 Primary-structure Planar Bedding 246.0 N155 31 Primary-structure Planar Bedding 248.2 N172 30 Primary-structure Planar Bedding 249.0 N170 25 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-426 of 1849 Page 424 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 249.5 N171 27 Primary-structure Planar Bedding 250.7 N145 44 Primary-structure Planar Bedding 251.9 N164 27 Primary-structure Planar Bedding 252.6 N171 24 Primary-structure Planar Bedding 253.5 N163 26 Primary-structure Planar Bedding 254.7 N169 41 Primary-structure Planar Bedding 255.1 N170 28 Primary-structure Planar Bedding 255.6 N154 31 Primary-structure Planar Bedding 257.3 N168 30 Primary-structure Planar Bedding 258.1 N161 36 Primary-structure Planar Bedding 258.9 N164 34 Primary-structure Planar Bedding 260.7 N172 25 Primary-structure Planar Bedding 261.5 N170 29 Primary-structure Planar Bedding 262.2 N167 32 Primary-structure Planar Bedding 262.5 N306 61 Fracture Discontinuous Hairline-fracture 262.8 N316 58 Fracture Discontinuous Hairline-fracture 264.4 N176 29 Primary-structure Planar Bedding 264.9 N163 29 Primary-structure Planar Bedding 267.8 N171 32 Primary-structure Planar Bedding 268.5 N316 54 Fracture Planar Hairline-fracture 269.2 N140 30 Primary-structure Planar Bedding 269.8 N293 65 Fracture Planar Hairline-fracture 270.5 N292 61 Fracture Planar Hairline-fracture 271.8 N147 29 Primary-structure Planar Bedding 273.0 N148 25 Primary-structure Planar Bedding 276.4 N167 29 Primary-structure Planar Bedding 277.2 N307 24 Fracture Planar Hairline-fracture 278.1 N021 13 Fracture Planar Hairline-fracture 279.4 N213 22 Fracture Planar Hairline-fracture 280.5 N153 34 Fracture Irregular Hairline-fracture 280.9 N066 73 Fracture Discontinuous Hairline-fracture 281.3 N222 76 Fracture Discontinuous Hairline-fracture 281.4 N045 65 Fracture Discontinuous Hairline-fracture 281.6 N165 32 Primary-structure Planar Bedding 282.1 N085 86 Fracture Planar Hairline-fracture 282.3 N144 34 Fracture Irregular Hairline-fracture 283.4 N150 36 Primary-structure Planar Bedding 283.9 N158 46 Primary-structure Planar Bedding 285.1 N147 35 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-427 of 1849 Page 425 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 285.4 N148 36 Fracture Irregular Hairline-fracture 286.2 N161 48 Primary-structure Irregular Bedding 286.5 N034 49 Fracture Planar Hairline-fracture 287.0 N020 68 Fracture Planar Hairline-fracture 287.2 N180 38 Primary-structure Planar Bedding 290.1 N168 38 Primary-structure Planar Bedding 290.5 N061 83 Fracture Planar Hairline-fracture 291.4 N155 36 Primary-structure Planar Bedding 291.8 N155 35 Primary-structure Planar Bedding 292.9 N163 38 Primary-structure Planar Bedding 295.4 N260 71 Fracture Planar Hairline-fracture 295.5 N292 65 Fracture Planar Hairline-fracture 295.9 N290 68 Fracture Planar Hairline-fracture 297.1 N147 29 Fracture Planar Open-fracture 297.3 N215 51 Primary-structure Planar Bedding 298.6 N0 53 62 Fracture Planar Hairline-fracture 298.7 N170 51 Primary-structure Irregular Bedding 299.3 N237 69 Fracture Planar Hairline-fracture 300.3 N243 68 Fracture Planar Hairline-fracture 300.7 N149 39 Primary-structure Planar Bedding 301.5 N318 67 Fracture Discontinuous Hairline-fracture 302.0 N163 45 Primary-structure Irregular Bedding 305.4 N157 41 Primary-structure Planar Bedding 307.6 N166 51 Primary-structure Planar Bedding 308.7 N164 33 Primary-structure Planar Bedding 309.2 N305 23 Fracture Planar Hairline-fracture 309.2 N106 89 Fracture Discontinuous Hairline-fracture 310.9 N162 41 Primary-structure Anastomosing Bedding 313.3 N197 56 Primary-structure Anastomosing Bedding 315.0 N159 42 Primary-structure Planar Bedding 317.5 N322 43 Fracture Planar Hairline-fracture 318.0 N161 35 Primary-structure Planar Bedding 318.7 N338 57 Fracture Planar Hairline-fracture GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-428 of 1849 Page 426 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC CLINCH RIVER top of borehole...

East:

Nortll Alt:

Zone from 318.664 to 45.749ft Interpretation 1 Dip data sets..

BHTVdips MP-423 45.749-318.664ft Dip-azimuth, fracture rose-diagram DIP DATA INTERPRETATION RGLDIP vsn 6.2 DIP-AZIMUTH. FRACTURE ROSE-DIAGRAM w

Borehole: MP-423 Azimuth I ncr= 10° N ~ 264 MP-423, Interpretation 1 318.664 to 45.749fl North ref. is true Depth units are feet N

s AMEC Project 6468-13-1072 E

0 1 0 20 30 40 50 60 70 80 Figure 1 01. Boring MP-423, Rose Diagram GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-429 of 1849 January 11, 2014 Page 427 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N54 1oo Borehole: MP-423 Sonde: BHTV Zone from: 0.000 to 318.668ft North ref is true Mean deviation: 1.38 to N323_58 End coordinates.

North: 6_ 169 East: -4.552 Down: 318.554 Azimuth of end: N323.58 Distance start-end: 7.667ft Viewpoint: N54 Data extrapolated to the surface from 41.468ft 200 300 Figure 102. Boring MP-423, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-430 of 1849 January 11, 2014 Page 428 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 CLINCH RIVER SMR PROJECT BOREHOLE MP-425 Receiver to Receiver V5 and V P Analysis 0

20

-~ -

1..:!!!-

I 40

~..

~...

iiiii?.

  • 60

.. -=-....

- ~

II.

--~

~

-~

~

80

~

~ -

~

~

~

1"'1f

~

100

-::!!::e

~..

IC::j, I

p

  • F-::::..

120

!!!:::=tl

....::4..

-="'

c 1-140 a..

-~

~

........ I-r-

w c

~

...... ~

160

~

ra.

r a

180

~ ~

~

Near-Far Receivers, Vs I.

f--

-=.-

f--

r"'

Near-Far Receivers, Vp f--

200

....i~

I

~

I.-;;:: ::::11

-= ;:;:._

.,eA

!!~!:iii 220

~..

~

.I

  • ~

240

... 1---....

-=

260 IC 280 0

5000 10000 15000 20000 25000 VELOCITY (ft/s)

Figure 103: Boring MP-425, Suspension R1-R2 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-431 of 1849 January 11, 2014 Page 429 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 54. Boring MP-425, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-425 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 8.2 9200 17540 0.31 2.5 10.2 9390 17090 0.28 3.1 11.5 9130 19050 0.35 3.5 13.1 7330 13330 0.28 4.0 14.8 7580 16670 0.37 4.5 16.4 7530 15500 0.35 5.0 18.0 8830 17090 0.32 5.5 19.7 9660 16670 0.25 6.0 21.3 8390 17090 0.34 6.5 23.0 7980 16260 0.34 7.0 24.6 7620 15500 0.34 7.5 26.3 5670 13890 0.40 8.0 27.9 6320 13330 0.36 8.5 29.5 7290 14180 0.32 9.0 31.2 6800 14810 0.37 9.5 32.8 6800 12580 0.29 10.0 34.5 7090 15870 0.38 10.5 36.1 7840 16670 0.36 11.0 37.7 5420 12820 0.39 11.5 39.4 7530 14810 0.33 12.0 41.0 9130 18020 0.33 12.5 42.7 6980 13330 0.31 13.0 44.3 8230 17090 0.35 13.5 45.9 7450 13890 0.30 14.0 47.6 8390 15500 0.29 14.5 49.2 6670 12120 0.28 15.0 50.9 6500 13890 0.36 15.5 52.5 8180 17090 0.35 16.0 54.1 7530 14810 0.33 16.5 55.8 8550 15150 0.27 17.0 57.4 7750 15500 0.33 17.5 59.1 6670 14490 0.37 18.0 60.7 6940 12820 0.29 18.5 62.3 7210 14180 0.33 19.0 64.0 7370 14490 0.33 19.5 65.6 7210 13610 0.30 20.0 67.3 7290 14180 0.32 20.5 68.9 7620 14490 0.31 21.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-432 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2800 5350 2860 5210 2780 5810 2230 4060 2310 5080 2300 4730 2690 5210 2940 5080 2560 5210 2430 4960 2320 4730 1730 4230 1930 4060 2220 4320 2070 4520 2070 3830 2160 4840 2390 5080 1650 3910 2300 4520 2780 5490 2130 4060 2510 5210 2270 4230 2560 4730 2030 3690 1980 4230 2490 5210 2300 4520 2610 4620 2360 4730 2030 4420 2120 3910 2200 4320 2250 4420 2200 4150 2220 4320 2320 4420 January 11, 2014 0.31 0.28 0.35 0.28 0.37 0.35 0.32 0.25 0.34 0.34 0.34 0.40 0.36 0.32 0.37 0.29 0.38 0.36 0.39 0.33 0.33 0.31 0.35 0.30 0.29 0.28 0.36 0.35 0.33 0.27 0.33 0.37 0.29 0.33 0.33 0.30 0.32 0.31 Page 430 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-425 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 70.9 7370 14180 0.32 21.6 72.2 7170 13330 0.30 22.0 73.8 8030 16260 0.34 22.5 75.5 7800 15870 0.34 23.0 77.1 7980 15150 0.31 23.5 79.1 7660 16670 0.37 24.1 80.4 7090 15870 0.38 24.5 82.0 8390 15150 0.28 25.0 83.7 8660 15870 0.29 25.5 85.3 8280 15500 0.30 26.0 86.9 8230 15150 0.29 26.5 88.6 8280 15500 0.30 27.0 90.2 8080 15500 0.31 27.5 91.9 7490 13890 0.29 28.0 93.5 7410 14490 0.32 28.5 95.1 7750 14490 0.30 29.0 96.8 8280 15150 0.29 29.5 98.4 8830 16260 0.29 30.0 100.1 7620 15500 0.34 30.5 101.7 7090 14810 0.35 31.0 103.4 7620 13890 0.28 31.5 105.0 7940 16260 0.34 32.0 106.6 7940 15870 0.33 32.5 108.3 7840 15870 0.34 33.0 109.9 7890 16260 0.35 33.5 111.6 8180 14810 0.28 34.0 113.2 8030 16260 0.34 34.5 114.8 7660 15500 0.34 35.0 116.5 7410 15500 0.35 35.5 118.1 7580 13330 0.26 36.0 119.8 7840 14180 0.28 36.5 121.4 7980 15150 0.31 37.0 123.0 7750 15870 0.34 37.5 124.7 7710 14490 0.30 38.0 126.6 8280 15150 0.29 38.6 128.0 7940 14180 0.27 39.0 129.6 7090 13890 0.32 39.5 131.2 7410 15150 0.34 40.0 132.9 7800 15870 0.34 40.5 134.8 7490 13610 0.28 41.1 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-433 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2250 4320 2180 4060 2450 4960 2380 4840 2430 4620 2340 5080 2160 4840 2560 4620 2640 4840 2520 4730 2510 4620 2520 4730 2460 4730 2280 4230 2260 4420 2360 4420 2520 4620 2690 4960 2320 4730 2160 4520 2320 4230 2420 4960 2420 4840 2390 4840 2400 4960 2490 4520 2450 4960 2340 4730 2260 4730 2310 4060 2390 4320 2430 4620 2360 4840 2350 4420 2520 4620 2420 4320 2160 4230 2260 4620 2380 4840 2280 4150 January 11, 2014 0.32 0.30 0.34 0.34 0.31 0.37 0.38 0.28 0.29 0.30 0.29 0.30 0.31 0.29 0.32 0.30 0.29 0.29 0.34 0.35 0.28 0.34 0.33 0.34 0.35 0.28 0.34 0.34 0.35 0.26 0.28 0.31 0.34 0.30 0.29 0.27 0.32 0.34 0.34 0.28 Page 431 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-425 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 136.2 7620 14490 0.31 41.5 137.8 8030 14490 0.28 42.0 139.4 8950 16260 0.28 42.5 141.1 9200 17540 0.31 43.0 142.7 8440 17090 0.34 43.5 144.4 7940 15500 0.32 44.0 146.0 7840 14490 0.29 44.5 147.6 7290 14180 0.32 45.0 149.3 6800 14810 0.37 45.5 150.9 7170 14180 0.33 46.0 152.6 8080 14810 0.29 46.5 154.2 8330 15870 0.31 47.0 155.8 8280 15150 0.29 47.5 157.5 8180 15500 0.31 48.0 159.1 8440 15870 0.30 48.5 160.8 7890 16260 0.35 49.0 162.4 7290 13610 0.30 49.5 164.0 7410 13610 0.29 50.0 165.7 7530 14490 0.31 50.5 167.3 6910 13610 0.33 51.0 169.0 6470 12120 0.30 51.5 170.6 6570 12820 0.32 52.0 172.2 6570 12820 0.32 52.5 173.9 6630 13070 0.33 53.0 175.5 6700 13070 0.32 53.5 177.2 7020 13070 0.30 54.0 178.8 7490 13890 0.29 54.5 180.5 7710 14180 0.29 55.0 182.1 7660 14180 0.29 55.5 184.1 7750 14180 0.29 56.1 185.4 7710 14810 0.31 56.5 187.0 7620 14180 0.30 57.0 188.7 7620 13610 0.27 57.5 190.3 7980 13890 0.25 58.0 192.3 8230 15150 0.29 58.6 193.6 8180 14490 0.27 59.0 195.2 7940 14180 0.27 59.5 197.2 8130 14810 0.28 60.1 198.5 7890 14810 0.30 60.5 200.1 7410 13890 0.30 61.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-434 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2320 4420 2450 4420 2730 4960 2800 5350 2570 5210 2420 4730 2390 4420 2220 4320 2070 4520 2180 4320 2460 4520 2540 4840 2520 4620 2490 4730 2570 4840 2400 4960 2220 4150 2260 4150 2300 4420 2110 4150 1970 3690 2000 3910 2000 3910 2020 3980 2040 3980 2140 3980 2280 4230 2350 4320 2340 4320 2360 4320 2350 4520 2320 4320 2320 4150 2430 4230 2510 4620 2490 4420 2420 4320 2480 4520 2400 4520 2260 4230 January 11, 2014 0.31 0.28 0.28 0.31 0.34 0.32 0.29 0.32 0.37 0.33 0.29 0.31 0.29 0.31 0.30 0.35 0.30 0.29 0.31 0.33 0.30 0.32 0.32 0.33 0.32 0.30 0.29 0.29 0.29 0.29 0.31 0.30 0.27 0.25 0.29 0.27 0.27 0.28 0.30 0.30 Page 432 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-425 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 201.8 7250 13330 0.29 61.5 203.4 7750 14490 0.30 62.0 205.1 7490 14180 0.31 62.5 206.7 7290 13610 0.30 63.0 208.3 7750 14490 0.30 63.5 210.0 7980 14810 0.30 64.0 211.6 7980 14180 0.27 64.5 213.3 7530 14810 0.33 65.0 214.9 7170 13070 0.28 65.5 216.5 7370 14810 0.34 66.0 218.2 7490 13610 0.28 66.5 219.8 7980 14810 0.30 67.0 221.5 7980 16260 0.34 67.5 223.1 7980 15500 0.32 68.0 224.7 7710 14180 0.29 68.5 226.4 7330 13890 0.31 69.0 228.0 7800 14180 0.28 69.5 229.7 8030 14490 0.28 70.0 231.3 7940 15150 0.31 70.5 232.9 7750 14810 0.31 71.0 234.6 7660 15500 0.34 71.5 236.2 7840 14810 0.31 72.0 237.9 7840 14180 0.28 72.5 239.5 7750 13610 0.26 73.0 241.1 7890 14490 0.29 73.5 242.8 7980 14810 0.30 74.0 244.4 8180 16260 0.33 74.5 246.1 8130 17090 0.35 75.0 247.7 7750 16260 0.35 75.5 249.3 7800 14810 0.31 76.0 251.0 7580 13610 0.28 76.5 252.6 7130 14180 0.33 77.0 254.3 7530 13610 0.28 77.5 255.9 7940 14490 0.29 78.0 257.6 7710 14180 0.29 78.5 259.2 7710 14490 0.30 79.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-435 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2210 4060 2360 4420 2280 4320 2220 4150 2360 4420 2430 4520 2430 4320 2300 4520 2180 3980 2250 4520 2280 4150 2430 4520 2430 4960 2430 4730 2350 4320 2230 4230 2380 4320 2450 4420 2420 4620 2360 4520 2340 4730 2390 4520 2390 4320 2360 4150 2400 4420 2430 4520 2490 4960 2480 5210 2360 4960 2380 4520 2310 4150 2170 4320 2300 4150 2420 4420 2350 4320 2350 4420 January 11, 2014 0.29 0.30 0.31 0.30 0.30 0.30 0.27 0.33 0.28 0.34 0.28 0.30 0.34 0.32 0.29 0.31 0.28 0.28 0.31 0.31 0.34 0.31 0.28 0.26 0.29 0.30 0.33 0.35 0.35 0.31 0.28 0.33 0.28 0.29 0.29 0.30 Page 433 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Nat. Gamma (CAL)

Nat. Gamma (DUIN)

Conductivity-Short Conductivity-Long Borehole Diameter Depth 0

CPS 150 0 CPS 150

-10 mS/m 30 -20 mS/m 20 2 INCH 3

Feet Conductivity-Short#2 Conductivity-Long#2

-10 mS/m 30 -20 mS/m 20 MP-425 r

lt

~

10 r-....

. ~

~

'\\

~

[!:

20 1\\

z

= r o 30

~

  • -f-

/-

7-It:- -

'S

~

f3 40

~

ItS

~

~

50

~-

z

~

~

60

~

J

__J 0

-~

~

70 1:-'-:

l or-:

1-----

-- - ~~

80

_ c. 1-1-

0=

-if" cc

-- oc E

1--

.~

90

_}

0 1--

-~

~

100

{

{

I ~

~~

~~

110

~

\\

I ~

F-w r-1.:::-

120

~ 1-- - F=

~ ~ --*

~- -

-- - ~=

~

- F= ~ ri 130

~

~

luj r--- -- -

~

I 10:::

140

~ f=

--~~

~

'\\

z

)

~

150 I(""

0::

r-

~

w L~E>-

160 I~

~

7 I=

I=

LD 1---

'"'1-fi= --

~

170

... ~

r-*

~---

L IL 1::!:

~

7 1-- 0 180

~

~

1/

/

w 190 I ~

-=

<~

c_

~

rt

'l

~

r-liE

---:1

~r-200 I>

0::

1--

0 c:o:..

~

r-= ~-

21 0 1).

_)_

I'""'

~

~~

220 I ~

  • ~

~

f-::li p-

~

~

230 I~

)

~

~

240 250

~

~

'? ~ --

I~

?

r

~

1:-

260

-~ --~-

r--

1----*

270 Figure 104. Boring MP-425, Induction, Natural Gamma and Caliper logs GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-436 of 1849 January 11, 2014 Page 434 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 55. Boring MP-425, Acoustic Televiewer Feature depth, dip azimuth, dip and description Depth Dip Structure Dip (feet) azimuth description 6.4 N234 27 Planar Bottom of surface casing 7.5 N318 59 Fracture Discontinuous Hairline-fracture 8.8 N152 34 Primary-structure Planar Bedding 9.8 N146 38 Primary-structure Irregular Bedding 11.8 N178 48 Primary-structure Irregular Bedding 12.8 N305 49 Fracture Irregular Hairline-fracture 14.1 N321 52 Fracture Discontinuous Hairline-fracture 14.2 N150 27 Primary-structure Irregular Bedding 15.0 N137 33 Primary-structure Planar Bedding 15.6 N323 55 Fracture Discontinuous Hairline-fracture 15.8 N159 32 Primary-structure Planar Bedding 16.3 N149 28 Primary-structure Planar Bedding 16.7 N332 50 Fracture Discontinuous Hairline-fracture 17.3 N147 34 Primary-structure Planar Bedding 18.2 N133 28 Primary-structure Planar Bedding 18.7 N148 31 Primary-structure Planar Bedding 19.5 N159 31 Primary-structure Planar Bedding 19.9 N315 59 Fracture Planar Hairline-fracture 20.6 N142 30 Primary-structure Planar Bedding 21.2 N152 29 Primary-structure Planar Bedding 21.6 N146 27 Primary-structure Planar Bedding 22.9 N147 30 Primary-structure Planar Bedding 24.2 N154 32 Primary-structure Planar Bedding 25.5 N152 22 Primary-structure Planar Bedding 27.1 N147 36 Fracture Planar Open-fracture 27.9 N159 26 Primary-structure Planar Bedding 28.9 N325 68 Fracture Irregular Hairline-fracture 29.6 N152 33 Primary-structure Planar Bedding 30.8 N176 30 Primary-structure Planar Bedding 32.6 N149 36 Primary-structure Planar Bedding 34.3 N149 34 Primary-structure Planar Bedding 34.8 N144 31 Primary-structure Planar Bedding 35.8 N149 33 Primary-structure Planar Bedding 36.5 N150 28 Primary-structure Planar Bedding 37.3 N305 61 Fracture Discontinuous Hairline-fracture 37.5 N151 34 Primary-structure Planar Bedding 38.7 N148 28 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-437 of 1849 Page 435 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 39.1 N142 31 Primary-structure Planar Bedding 40.0 N147 36 Primary-structure Planar Bedding 41.5 N156 26 Primary-structure Planar Bedding 42.3 N144 32 Primary-structure Planar Bedding 43.3 N145 36 Primary-structure Irregular Bedding 44.2 N162 42 Primary-structure Irregular Bedding 44.6 N141 32 Primary-structure Planar Bedding 45.3 N169 32 Primary-structure Irregular Bedding 46.2 N163 35 Primary-structure Planar Bedding 47.0 N118 25 Primary-structure Planar Bedding 47.4 N165 45 Primary-structure Planar Bedding 47.4 N312 46 Fracture Discontinuous Hairline-fracture 47.8 N160 30 Primary-structure Planar Bedding 48.3 N159 30 Primary-structure Planar Bedding 48.9 N139 29 Primary-structure Planar Bedding 49.9 N154 28 Primary-structure Planar Bedding 51.0 N154 25 Primary-structure Planar Bedding 51.6 N134 22 Primary-structure Planar Bedding 52.1 N151 33 Primary-structure Irregular Bedding 53.0 N175 45 Fracture Irregular Hairline-fracture 53.2 N325 42 Fracture Discontinuous Hairline-fracture 54.3 N157 38 Primary-structure Planar Bedding 54.7 N311 41 Fracture Discontinuous Hairline-fracture 55.2 N149 26 Fracture Irregular Hairline-fracture 56.0 N149 33 Primary-structure Irregular Bedding 56.8 N151 38 Primary-structure Irregular Bedding 57.8 N137 27 Fracture Irregular Hairline-fracture 58.8 N150 31 Primary-structure Irregular Bedding 62.5 N155 34 Primary-structure Irregular Bedding 64.8 N157 40 Primary-structure Irregular Bedding 66.9 N144 28 Primary-structure Irregular Bedding 67.7 N327 40 Fracture Discontinuous Hairline-fracture 69.4 N159 36 Primary-structure Irregular Bedding 69.4 N327 55 Fracture Discontinuous Hairline-fracture 73.2 N165 42 Primary-structure Irregular Bedding 73.9 N153 33 Primary-structure Irregular Bedding 74.3 N153 30 Fracture Irregular Hairline-fracture 75.4 N167 29 Primary-structure Planar Bedding 76.7 N156 34 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-438 of 1849 Page 436 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 77.1 N152 33 Primary-structure Planar Bedding 77.5 N147 32 Primary-structure Planar Bedding 78.1 N319 47 Fracture Discontinuous Hairline-fracture 78.4 N144 26 Primary-structure Planar Bedding 78.5 N155 36 Primary-structure Planar Bedding 79.9 N321 46 Fracture Irregular Open-fracture 81.6 N145 32 Primary-structure Planar Bedding 84.2 N148 33 Primary-structure Planar Bedding 85.8 N138 34 Primary-structure Planar Bedding 87.5 N158 34 Primary-structure Planar Bedding 88.4 N165 36 Primary-structure Planar Bedding 90.2 N147 37 Primary-structure Planar Bedding 91.6 N155 33 Primary-structure Planar Bedding 94.3 N153 37 Primary-structure Planar Bedding 94.5 N325 48 Fracture Discontinuous Hairline-fracture 94.9 N149 35 Primary-structure Planar Bedding 95.2 N148 35 Primary-structure Planar Bedding 95.6 N330 60 Fracture Discontinuous Hairline-fracture 96.3 N154 33 Primary-structure Planar Bedding 96.6 N319 44 Fracture Discontinuous Hairline-fracture 97.0 N152 34 Primary-structure Planar Bedding 98.5 N324 46 Fracture Planar Hairline-fracture 99.2 N151 34 Primary-structure Planar Bedding 99.8 N155 36 Primary-structure Planar Bedding 99.9 N325 52 Fracture Discontinuous Hairline-fracture 100.3 N149 34 Primary-structure Planar Bedding 100.4 N326 49 Fracture Discontinuous Hairline-fracture 103.4 N325 46 Fracture Discontinuous Hairline-fracture 103.8 N322 49 Fracture Discontinuous Hairline-fracture 103.9 N147 35 Primary-structure Planar Bedding 104.2 N148 31 Primary-structure Planar Bedding 105.0 N324 63 Fracture Discontinuous Hairline-fracture 105.2 N147 33 Primary-structure Planar Bedding 106.4 N151 34 Primary-structure Planar Bedding 107.6 N329 55 Fracture Planar Hairline-fracture 107.7 N148 33 Primary-structure Planar Bedding 109.3 N149 33 Primary-structure Planar Bedding 109.9 N327 58 Fracture Discontinuous Hairline-fracture 110.0 N144 32 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-439 of 1849 Page 437 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 110.5 N324 58 Fracture Discontinuous Hairline-fracture 110.7 N151 33 Primary-structure Planar Bedding 111.5 N154 34 Primary-structure Planar Bedding 111.9 N328 60 Fracture Discontinuous Hairline-fracture 114.3 N148 32 Primary-structure Planar Bedding 114.9 N145 34 Primary-structure Planar Bedding 118.3 N332 65 Fracture Discontinuous Hairline-fracture 118.5 N153 36 Primary-structure Planar Bedding 119.1 N148 34 Primary-structure Planar Bedding 120.5 N146 35 Primary-structure Planar Bedding 122.0 N325 60 Fracture Planar Hairline-fracture 122.8 N324 52 Fracture Discontinuous Hairline-fracture 122.8 N149 35 Primary-structure Planar Bedding 125.1 N149 35 Primary-structure Planar Bedding 125.7 N323 54 Fracture Discontinuous Hairline-fracture 125.9 N148 26 Primary-structure Planar Bedding 126.6 N326 53 Fracture Discontinuous Hairline-fracture 127.5 N150 31 Primary-structure Planar Bedding 128.3 N152 35 Primary-structure Planar Bedding 128.9 N147 34 Primary-structure Planar Bedding 129.5 N328 59 Fracture Irregular Hairline-fracture 129.8 N146 27 Primary-structure Planar Bedding 131.0 N146 34 Primary-structure Planar Bedding 133.7 N320 67 Fracture Discontinuous Hairline-fracture 133.9 N145 36 Primary-structure Planar Bedding 134.5 N335 53 Fracture Discontinuous Hairline-fracture 134.9 N140 33 Primary-structure Planar Bedding 136.9 N323 60 Fracture Irregular Hairline-fracture 137.6 N149 43 Primary-structure Planar Bedding 137.7 N319 55 Fracture Irregular Hairline-fracture 138.9 N153 34 Primary-structure Planar Bedding 139.7 N150 34 Primary-structure Planar Bedding 140.9 N148 36 Primary-structure Planar Bedding 141.8 N152 36 Primary-structure Planar Bedding 142.3 N340 45 Fracture Discontinuous Hairline-fracture 142.4 N154 36 Primary-structure Planar Bedding 142.7 N147 36 Primary-structure Planar Bedding 145.8 N160 40 Primary-structure Planar Bedding 146.2 N146 34 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-440 of 1849 Page 438 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 146.2 N328 55 Fracture Discontinuous Hairline-fracture 147.0 N323 67 Fracture Discontinuous Hairline-fracture 148.3 N150 35 Primary-structure Planar Bedding 149.9 N325 56 Fracture Discontinuous Hairline-fracture 150.0 N145 33 Primary-structure Planar Bedding 151.9 N328 46 Fracture Discontinuous Hairline-fracture 152.0 N158 40 Primary-structure Planar Bedding 152.4 N148 35 Primary-structure Planar Bedding 152.7 N157 39 Primary-structure Planar Bedding 153.0 N324 59 Fracture Discontinuous Hairline-fracture 153.5 N157 34 Primary-structure Planar Bedding 155.1 N148 36 Primary-structure Planar Bedding 156.8 N312 68 Fracture Discontinuous Hairline-fracture 157.5 N155 35 Primary-structure Planar Bedding 157.7 N156 32 Primary-structure Planar Bedding 159.0 N331 44 Fracture Discontinuous Hairline-fracture 159.3 N145 30 Primary-structure Planar Bedding 160.0 N152 35 Primary-structure Planar Bedding 160.9 N150 34 Primary-structure Planar Bedding 160.9 N324 37 Fracture Discontinuous Hairline-fracture 161.4 N145 33 Primary-structure Planar Bedding 163.0 N149 38 Primary-structure Planar Bedding 163.4 N151 34 Primary-structure Planar Bedding 165.5 N146 31 Primary-structure Planar Bedding 166.9 N129 29 Primary-structure Planar Bedding 168.7 N146 37 Primary-structure Planar Bedding 170.5 N148 35 Primary-structure Planar Bedding 172.6 N153 32 Primary-structure Planar Bedding 174.5 N147 37 Primary-structure Planar Bedding 175.4 N147 37 Primary-structure Planar Bedding 176.5 N143 37 Primary-structure Planar Bedding 176.7 N140 37 Primary-structure Planar Bedding 177.4 N141 33 Primary-structure Planar Bedding 177.9 N149 38 Primary-structure Planar Bedding 178.4 N338 46 Fracture Discontinuous Hairline-fracture 178.6 N142 34 Primary-structure Planar Bedding 179.2 N146 36 Primary-structure Planar Bedding 179.5 N328 48 Fracture Discontinuous Hairline-fracture 180.1 N146 34 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-441 of 1849 Page 439 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 181.1 N146 34 Primary-structure Planar Bedding 182.9 N145 34 Primary-structure Planar Bedding 183.9 N144 36 Primary-structure Planar Bedding 184.6 N145 35 Primary-structure Planar Bedding 185.5 N148 35 Primary-structure Planar Bedding 186.9 N145 40 Primary-structure Planar Bedding 187.8 N318 50 Fracture Irregular Hairline-fracture 188.1 N150 34 Primary-structure Planar Bedding 189.6 N146 39 Primary-structure Planar Bedding 190.2 N323 66 Fracture Discontinuous Hairline-fracture 190.3 N163 27 Primary-structure Planar Bedding 190.9 N159 43 Primary-structure Planar Bedding 191.6 N323 50 Fracture Discontinuous Hairline-fracture 191.9 N148 39 Primary-structure Planar Bedding 192.5 N146 37 Primary-structure Planar Bedding 193.5 N146 34 Primary-structure Planar Bedding 195.8 N147 35 Primary-structure Planar Bedding 196.8 N328 55 Fracture Planar Hairline-fracture 197.2 N151 36 Primary-structure Planar Bedding 197.9 N149 35 Primary-structure Planar Bedding 198.8 N148 36 Primary-structure Planar Bedding 199.8 N159 38 Primary-structure Planar Bedding 201.3 N143 37 Primary-structure Planar Bedding 201.6 N324 53 Fracture Discontinuous Hairline-fracture 202.0 N138 36 Primary-structure Planar Bedding 202.4 N146 38 Primary-structure Planar Bedding 203.0 N321 71 Fracture Discontinuous Hairline-fracture 203.7 N145 34 Primary-structure Planar Bedding 207.0 N314 68 Fracture Discontinuous Hairline-fracture 207.4 N145 35 Primary-structure Planar Bedding 209.7 N137 35 Primary-structure Planar Bedding 211.0 N304 48 Fracture Discontinuous Hairline-fracture 211.2 N146 38 Primary-structure Planar Bedding 211.9 N147 36 Primary-structure Planar Bedding 212.4 N145 37 Primary-structure Planar Bedding 213.1 N158 52 Primary-structure Planar Bedding 213.9 N151 38 Primary-structure Planar Bedding 219.5 N146 36 Primary-structure Planar Bedding 221.7 N142 36 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-442 of 1849 Page 440 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 223.0 N156 38 Primary-structure Planar Bedding 223.7 N146 38 Primary-structure Planar Bedding 223.9 N143 37 Primary-structure Planar Bedding 224.9 N324 29 Fracture Discontinuous Hairline-fracture 228.0 N144 40 Primary-structure Planar Bedding 228.8 N144 39 Primary-structure Planar Bedding 231.6 N146 39 Primary-structure Planar Bedding 232.1 N335 45 Fracture Discontinuous Hairline-fracture 232.9 N323 38 Fracture Discontinuous Hairline-fracture 233.9 N139 35 Primary-structure Planar Bedding 235.3 N142 36 Primary-structure Planar Bedding 236.1 N144 37 Primary-structure Planar Bedding 236.4 N148 37 Primary-structure Planar Bedding 237.3 N325 56 Fracture Discontinuous Hairline-fracture 237.8 N144 38 Primary-structure Planar Bedding 237.9 N317 53 Fracture Discontinuous Hairline-fracture 238.5 N145 35 Primary-structure Planar Bedding 239.3 N143 37 Primary-structure Planar Bedding 240.3 N145 35 Primary-structure Planar Bedding 240.4 N325 45 Fracture Discontinuous Hairline-fracture 241.6 N143 35 Primary-structure Planar Bedding 242.1 N147 37 Primary-structure Planar Bedding 242.6 N151 38 Primary-structure Planar Bedding 243.4 N144 38 Primary-structure Planar Bedding 243.5 N326 53 Fracture Discontinuous Hairline-fracture 243.7 N321 39 Fracture Planar Hairline-fracture 244.1 N146 41 Primary-structure Planar Bedding 245.0 N144 37 Primary-structure Planar Bedding 246.0 N326 57 Fracture Irregular Hairline-fracture 246.1 N143 36 Primary-structure Planar Bedding 250.0 N147 34 Primary-structure Planar Bedding 250.4 N320 53 Fracture Planar Hairline-fracture 251.0 N144 40 Primary-structure Planar Bedding 252.0 N151 38 Primary-structure Planar Bedding 254.3 N148 36 Primary-structure Planar Bedding 255.2 N326 45 Fracture Planar Hairline-fracture 256.1 N123 30 Primary-structure Planar Bedding 257.6 N137 35 Primary-structure Planar Bedding 257.7 N326 62 Fracture Discontinuous Hairline-fracture GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-443 of 1849 Page 441 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 258.3 N319 45 Fracture Discontinuous Hairline-fracture 258.7 N323 45 Fracture Discontinuous Hairline-fracture 259.0 N322 48 Fracture Discontinuous Hairline-fracture 259.7 N148 39 Primary-structure Planar Bedding 259.8 N329 48 Fracture Discontinuous Hairline-fracture 260.8 N136 37 Primary-structure Planar Bedding 261.3 N323 42 Fracture Discontinuous Hairline-fracture 262.6 N148 37 Primary-structure Planar Bedding 263.6 N148 35 Primary-structure Planar Bedding 264.7 N145 31 Primary-structure Planar Bedding 265.5 N141 37 Primary-structure Planar Bedding 266.5 N142 37 Primary-structure Planar Bedding 266.5 N320 42 Fracture Discontinuous Hairline-fracture 267.3 N143 37 Primary-structure Planar Bedding 267.7 N321 47 Fracture Discontinuous Hairline-fracture 267.9 N144 37 Primary-structure Planar Bedding 269.7 N141 35 Primary-structure Planar Bedding 270.5 N326 52 Fracture Discontinuous Hairline-fracture 270.6 N146 38 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-444 of 1849 Page 442 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC CLINCH RIVER top of borehole...

East:

Nortll Alt:

Zone from 271.088 to 5.906ft Interpretation 1 Dip data sets..

BHTVdips MP-425 5.906-271.088ft Dip-azimuth, fracture rose-diagram DIP DATA INTERPRETATION RGLDIP vsn 6.2 DIP-AZIMUTH. FRACTURE ROSE-DIAGRAM w

Borehole: MP-425 Azimuth I ncr= 10° N ~ 290 MP-425, Interpretation 1 271.088 to 5.906fl North ref. is true Depth units are feet N

s AMEC Project 6468-13-1072 E

0 10 20 30 40 50 60 70 80 90100110120 Figure 1 05. Boring MP-425, Rose Diagram GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-445 of 1849 January 11, 2014 Page 443 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N139 Borehole: MP-425 Sonde: BHTV Zone from: 0.000 to 271.666ft North ref is true Mean deviation: 28.53 to N48_62 End coordinates.

North: 85_782 East : 97.376 Down : 238.662 Azimuth of end: N48.62 Distance start-end: 129.771ft Viewpoint: N139 Data extrapolated to the surface from 4.930ft 50-75 100 125 150 175 200 225-Figure 106. Boring MP-425, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-446 of 1849 January 11, 2014 Page 444 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 CLINCH RIVER SMR PROJECT BOREHOLE MP-426 Receiver to Receiver V5 and VP Analysis 0

~ Near-Far Receivers, Vs

[-----

[-----

20 Near-Far Receivers, Vp f--

40

11..

.; ~

  • --r-

~

60

=-

~

=--

  • f'-,

~

~

80 p;.

- ~

6.

.. d

~ -

100 a:-

~

r-

-.. r-..

120

., 1-e.

~.

  • ~=: :::

1-=:: ~

-...I..

5

c 1-140 a..

~

.;:::II

~

-=: -

w c

~

160

-t:::ll

.:!I pe -. ~

..:= r-180

...... ~

.... I--&

r I~

.. :::.ii 200

~

~

1"'11

  • ~

..:=; -

.:!I a:!""

220

  • ~ -

!Sol 240 1-

-e.. ~a

-.:: r-

~

  • ~

~ -

t.

260 280 0

5000 10000 15000 20000 25000 VELOCITY (ft/s)

Figure 107: Boring MP-426, Suspension R1-R2 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-447 of 1849 January 11, 2014 Page 445 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 56. Boring MP-426, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-426 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 32.8 8550 10.0 34.5 5210 11110 0.36 10.5 36.1 7750 15150 0.32 11.0 37.7 7450 13070 0.26 11.5 39.4 8180 15150 0.29 12.0 39.4 7840 15500 0.33 12.0 41.0 7750 14810 0.31 12.5 42.7 8660 15500 0.27 13.0 44.3 8660 14490 0.22 13.5 45.9 9260 15150 0.20 14.0 47.6 7840 17540 0.38 14.5 49.2 7750 19610 0.41 15.0 50.9 7330 15150 0.35 15.5 52.5 7840 18520 0.39 16.0 54.1 6940 14180 0.34 16.5 55.8 7090 12820 0.28 17.0 57.4 9800 18020 0.29 17.5 59.1 9520 17090 0.27 18.0 60.7 7170 15500 0.36 18.5 62.3 9010 19050 0.36 19.0 64.0 9950 17090 0.24 19.5 65.6 10100 17090 0.23 20.0 67.3 8330 16670 0.33 20.5 68.9 9590 18020 0.30 21.0 70.5 8180 15500 0.31 21.5 72.2 9010 15150 0.23 22.0 73.8 10260 18020 0.26 22.5 75.5 9730 21510 0.37 23.0 77.1 9520 17540 0.29 23.5 78.7 10180 20830 0.34 24.0 80.4 9520 18520 0.32 24.5 82.0 10500 17090 0.20 25.0 83.7 11590 20200 0.25 25.5 85.3 10340 19610 0.31 26.0 86.9 10180 18520 0.28 26.5 88.6 7940 18020 0.38 27.0 90.2 10670 18020 0.23 27.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-448 of 1849 Metric Units Velocity Vs (m/s) 1590 2360 2270 2490 2390 2360 2640 2640 2820 2390 2360 2230 2390 2120 2160 2990 2900 2180 2750 3030 3080 2540 2920 2490 2750 3130 2970 2900 3100 2900 3200 3530 3150 3100 2420 3250 January 11, 2014 Poisson's Vo Ratio (m/s) 2610 3390 0.36 4620 0.32 3980 0.26 4620 0.29 4730 0.33 4520 0.31 4730 0.27 4420 0.22 4620 0.20 5350 0.38 5980 0.41 4620 0.35 5640 0.39 4320 0.34 3910 0.28 5490 0.29 5210 0.27 4730 0.36 5810 0.36 5210 0.24 5210 0.23 5080 0.33 5490 0.30 4730 0.31 4620 0.23 5490 0.26 6550 0.37 5350 0.29 6350 0.34 5640 0.32 5210 0.20 6160 0.25 5980 0.31 5640 0.28 5490 0.38 5490 0.23 Page 446 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-426 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 91.9 10930 19610 0.27 28.0 93.5 9660 20200 0.35 28.5 95.1 10750 19610 0.28 29.0 97.1 10100 20200 0.33 29.6 98.4 10180 19610 0.32 30.0 100.1 11110 20200 0.28 30.5 101.7 11400 19610 0.24 31.0 103.4 11590 19610 0.23 31.5 105.0 11490 19050 0.21 32.0 106.6 11590 19610 0.23 32.5 108.3 10580 19050 0.28 33.0 109.9 8390 17540 0.35 33.5 111.6 8660 18520 0.36 34.0 113.2 9520 20200 0.36 34.5 114.8 10030 18020 0.28 35.0 116.5 10840 19050 0.26 35.5 118.1 11700 20200 0.25 36.0 119.8 12120 20200 0.22 36.5 121.4 9800 20200 0.35 37.0 123.0 8830 19050 0.36 37.5 124.7 9880 20830 0.36 38.0 126.3 11300 19050 0.23 38.5 128.0 11020 19610 0.27 39.0 128.9 10260 19050 0.30 39.3 129.6 10750 19610 0.28 39.5 131.2 11900 20830 0.26 40.0 132.9 11700 20830 0.27 40.5 134.5 11590 20200 0.25 41.0 136.2 11900 20200 0.23 41.5 137.8 11700 20830 0.27 42.0 139.4 11110 18520 0.22 42.5 141.1 10840 18520 0.24 43.0 142.7 9660 17540 0.28 43.5 144.4 9070 17540 0.32 44.0 146.0 9590 19610 0.34 44.5 147.6 10420 19050 0.29 45.0 149.3 10340 17540 0.23 45.5 150.9 10580 18020 0.24 46.0 152.6 10180 18520 0.28 46.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-449 of 1849 Metric Units Velocity Vs (m/s) 3330 2940 3280 3080 3100 3390 3470 3530 3500 3530 3230 2560 2640 2900 3060 3300 3560 3690 2990 2690 3010 3440 3360 3130 3280 3630 3560 3530 3630 3560 3390 3300 2940 2760 2920 3180 3150 3230 3100 January 11, 2014 Poisson's Vo Ratio (m/s) 5980 0.27 6160 0.35 5980 0.28 6160 0.33 5980 0.32 6160 0.28 5980 0.24 5980 0.23 5810 0.21 5980 0.23 5810 0.28 5350 0.35 5640 0.36 6160 0.36 5490 0.28 5810 0.26 6160 0.25 6160 0.22 6160 0.35 5810 0.36 6350 0.36 5810 0.23 5980 0.27 5810 0.30 5980 0.28 6350 0.26 6350 0.27 6160 0.25 6160 0.23 6350 0.27 5640 0.22 5640 0.24 5350 0.28 5350 0.32 5980 0.34 5810 0.29 5350 0.23 5490 0.24 5640 0.28 Page 447 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-426 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 154.2 10580 19610 0.29 47.0 155.8 10930 18520 0.23 47.5 157.5 11020 19610 0.27 48.0 159.1 11020 19610 0.27 48.5 160.8 10750 18020 0.22 49.0 162.4 10750 20830 0.32 49.5 164.0 10180 20200 0.33 50.0 165.7 10500 18020 0.24 50.5 167.3 11300 21510 0.31 51.0 169.0 10500 19050 0.28 51.5 170.6 10260 17540 0.24 52.0 172.2 11700 19610 0.22 52.5 173.9 10670 18020 0.23 53.0 175.5 10750 17540 0.20 53.5 177.2 11200 20200 0.28 54.0 178.8 11020 19610 0.27 54.5 180.5 10180 18520 0.28 55.0 182.1 10500 18520 0.26 55.5 183.7 11300 19610 0.25 56.0 185.4 11490 20200 0.26 56.5 187.0 11200 20200 0.28 57.0 188.7 11200 18520 0.21 57.5 190.3 11200 20830 0.30 58.0 191.9 11300 19610 0.25 58.5 193.6 11900 20830 0.26 59.0 195.2 12010 20200 0.23 59.5 196.9 11490 21510 0.30 60.0 198.5 11110 20200 0.28 60.5 200.1 11800 19610 0.22 61.0 201.8 9660 17090 0.27 61.5 203.4 8710 18520 0.36 62.0 205.1 10500 20200 0.32 62.5 206.7 11400 19610 0.24 63.0 208.3 9520 19610 0.35 63.5 210.0 10500 19610 0.30 64.0 211.6 10750 18520 0.25 64.5 213.3 10930 18020 0.21 65.0 214.9 10260 18520 0.28 65.5 216.5 10260 17540 0.24 66.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-450 of 1849 Metric Units Velocity Vs (m/s) 3230 3330 3360 3360 3280 3280 3100 3200 3440 3200 3130 3560 3250 3280 3420 3360 3100 3200 3440 3500 3420 3420 3420 3440 3630 3660 3500 3390 3600 2940 2660 3200 3470 2900 3200 3280 3330 3130 3130 January 11, 2014 Poisson's Vo Ratio (m/s) 5980 0.29 5640 0.23 5980 0.27 5980 0.27 5490 0.22 6350 0.32 6160 0.33 5490 0.24 6550 0.31 5810 0.28 5350 0.24 5980 0.22 5490 0.23 5350 0.20 6160 0.28 5980 0.27 5640 0.28 5640 0.26 5980 0.25 6160 0.26 6160 0.28 5640 0.21 6350 0.30 5980 0.25 6350 0.26 6160 0.23 6550 0.30 6160 0.28 5980 0.22 5210 0.27 5640 0.36 6160 0.32 5980 0.24 5980 0.35 5980 0.30 5640 0.25 5490 0.21 5640 0.28 5350 0.24 Page 448 of 1847 RCN: CRP-111 0.0