Part 08 Enclosures (Rev. 2) - Part 08 - Enclosures - Subsurface Data Report - Appendix C - Pages 101-150
ML19030A668
Person / Time
Site: Clinch River
Issue date: 01/18/2019
From: James Shea
Tennessee Valley Authority
To:
Office of New Reactors
Fetter A
References
TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.6, CRN.P.PART08, CRN.P.PART08.2
Download: ML19030A668 (50)


Text

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project Depth Dip (feet) azimuth 262.5 N159 263.4 N155 264.2 N158 264.6 N155 265.3 N145 268.6 N161 271.9 N148 273.5 N177 274.1 N144 275.0 N151 276.3 N157 279.0 N141 283.9 N151 289.8 N148 291.3 N157 299.7 N169 300.5 N151 301.2 N163 302.3 N132 314.5 N146 314.9 N148 315.2 N138 315.6 N319 315.9 N150 318.9 N336 319.5 N149 319.9 N359 320.4 N323 320.6 N341 322.0 N153 324.4 N159 329.1 N143 333.4 N154 333.7 N002 340.8 N338 343.9 N356 AMEC Project 6468-13-1072 Structure Dip description 41 Primary-structure Planar Bedding 28 Primary-structure Planar Bedding 35 Primary-structure Planar Bedding 31 Primary-structure Planar Bedding 33 Primary-structure Planar Bedding 32 Primary-structure Planar Bedding 34 Primary-structure Planar Bedding 32 Primary-structure Planar Bedding 37 Primary-structure Planar Bedding 32 Primary-structure Planar Bedding 28 Primary-structure Planar Bedding 34 Primary-structure Planar Bedding 30 Primary-structure Planar Bedding 27 Primary-structure Planar Bedding 32 Primary-structure Planar Bedding 36 Primary-structure Planar Bedding 26 Primary-structure Planar Bedding 34 Primary-structure Planar Bedding 33 Primary-structure Planar Bedding 34 Primary-structure Planar Bedding 33 Primary-structure Planar Bedding 33 Primary-structure Planar Bedding 53 Fracture Planar Hairline-fracture 33 Primary-structure Planar Bedding 53 Fracture Planar Hairline-fracture 31 Primary-structure Planar Bedding 54 Fracture Planar Hairline-fracture 51 Fracture Planar Hairline-fracture 69 Fracture Planar Hairline-fracture 32 Primary-structure Planar Bedding 35 Primary-structure Planar Bedding 33 Primary-structure Planar Bedding 38 Primary-structure Planar Bedding 72 Fracture Discontinuous Hairline-fracture 80 Fracture Discontinuous Hairline-fracture 52 Fracture Discontinuous Hairline-fracture GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 99 of 1847 RCN: CRP-111 0.0 Page C1-101 of 1849

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC CLINCH RIVER top of borehole...

East:

Nortll Alt:

Zone from 344.420 to 5.699ft Interpretation 1 Dip data sets..

BHTVdips MP-102 5.699 -

344.420ft Dip-azimuth, fracture rose-diagram DIP DATA INTERPRETATION RGLDIP vsn 6.2 DIP-AZIMUTH. FRACTURE ROSE-DIAGRAM w

Borehole: MP-102 Azimuth I ncr= 10° N ~ 229 MP-102, Interpretation 1 344.420 to 5.699fl North ref. is true Depth units are feet N

s AMEC Project 6468-13-1072 E

0 1 0 20 30 40 50 60 70 80 90 1 00 Figure 11. Boring MP-1 02, Rose Diagram GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-102 of 1849 January 11, 2014 Page 1 00 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N281 100

- r Borehole: MP-102 Sonde: BHTV Zone from: 0.000 to 348.424ft North ref is true Mean deviation: 0.70 to N 191_46 End coordinates.

North: -4_ 177 East: -0.847 Down : 348.373 Azimuth of end: N191.47 Distance start-end: 4.262ft Viewpoint: N281 Data extrapolated to the surface from 5.312ft I

I I

I I II 100 II

~ I II ll II II 200-11 II II

-II I

I 300-1 I

I 100

- ------ -1 Figure 12. Boring MP-1 02, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-103 of 1849 January 11, 2014 Page 101 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 0

20 40 60 g

80

c 1-a..

w c 100 120 140 160 180 0

CLINCH RIVER SMR PROJECT BOREHOLE MP-111 Receiver to Receiver V5 and VP Analysis I

I I

I

--+- Near-Far Receivers, Vs Near-Far Receivers, Vp

-.;2

~..

..... ~


~

I

~

.~

  • ~

~

I..:: -

-r------,

II-

'::1

~

p.

.__ r-...

.: r---

~

1:: -

......4 ~

~

r....-

~-

.. ~

1!-

-=::::: h

~

.. b:.

~

~

  • I.

IF-

~.-

..-A ~

.r

-~..

.......... t-.

r-......

~

~

5000 10000 15000 20000 VELOCITY (ft/s)

Figure 13: Boring MP-111, Suspension R1-R2 P-and Swwave velocities r--

r--

f--

25000 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 1 02 of 1847 RCN: CRP-111 0.0 Page C1-104 of 1849

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 9. Boring MP-111, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-111 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 34.5 2370 4730 0.33 10.5 36.1 2800 7250 0.41 11.0 37.7 5010 10260 0.34 11.5 39.4 4420 9130 0.35 12.0 41.0 6500 13070 0.34 12.5 42.7 6090 13070 0.36 13.0 44.3 5460 11110 0.34 13.5 45.9 5700 11490 0.34 14.0 47.6 5980 12120 0.34 14.5 49.2 6230 12580 0.34 15.0 50.9 6380 12820 0.34 15.5 52.5 6410 12350 0.32 16.0 54.1 6320 12820 0.34 16.5 55.8 6230 12580 0.34 17.0 57.4 6290 12820 0.34 17.5 59.1 6060 11900 0.33 18.0 60.7 6010 11700 0.32 18.5 62.3 6120 11900 0.32 19.0 64.0 5650 10750 0.31 19.5 65.6 5190 12120 0.39 20.0 67.3 6060 11300 0.30 20.5 68.9 6260 13070 0.35 21.0 70.9 5070 13330 0.42 21.6 72.2 6570 13330 0.34 22.0 73.8 8030 16260 0.34 22.5 75.5 7980 16670 0.35 23.0 77.1 8830 17540 0.33 23.5 78.7 8710 16260 0.30 24.0 80.4 8030 17090 0.36 24.5 82.0 8180 16670 0.34 25.0 83.7 9520 17540 0.29 25.5 85.3 9800 19050 0.32 26.0 86.9 9460 17540 0.30 26.5 88.6 9880 17540 0.27 27.0 90.2 9460 18020 0.31 27.5 91.9 9460 19050 0.34 28.0 93.5 8950 16670 0.30 28.5 95.1 7940 15150 0.31 29.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-105 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 720 850 1530 1350 1980 1860 1670 1740 1820 1900 1940 1950 1930 1900 1920 1850 1830 1860 1720 1580 1850 1910 1550 2000 2450 2430 2690 2660 2450 2490 2900 2990 2880 3010 2880 2880 2730 2420 January 11, 2014 1440 2210 3130 2780 3980 3980 3390 3500 3690 3830 3910 3760 3910 3830 3910 3630 3560 3630 3280 3690 3440 3980 4060 4060 4960 5080 5350 4960 5210 5080 5350 5810 5350 5350 5490 5810 5080 4620 0.33 0.41 0.34 0.35 0.34 0.36 0.34 0.34 0.34 0.34 0.34 0.32 0.34 0.34 0.34 0.33 0.32 0.32 0.31 0.39 0.30 0.35 0.42 0.34 0.34 0.35 0.33 0.30 0.36 0.34 0.29 0.32 0.30 0.27 0.31 0.34 0.30 0.31 Page 1 03 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-111 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 96.8 9660 15870 0.21 29.5 98.4 9800 18520 0.31 30.0 100.1 9520 18520 0.32 30.5 101.7 9010 17090 0.31 31.0 103.4 9200 16670 0.28 31.5 105.0 9070 16670 0.29 32.0 106.6 9260 16260 0.26 32.5 108.3 9390 17090 0.28 33.0 109.9 9260 17540 0.31 33.5 111.6 9260 16260 0.26 34.0 113.2 9590 17090 0.27 34.5 114.8 9200 18520 0.34 35.0 116.5 9800 16670 0.24 35.5 118.4 9590 18020 0.30 36.1 119.8 9010 16260 0.28 36.5 121.4 9070 16670 0.29 37.0 123.0 9070 16260 0.27 37.5 124.7 9660 16670 0.25 38.0 126.3 8660 16260 0.30 38.5 128.0 9130 18520 0.34 39.0 129.6 9260 20200 0.37 39.5 131.2 8890 17090 0.31 40.0 132.9 8890 17090 0.31 40.5 134.5 9200 16260 0.26 41.0 136.2 9260 19050 0.35 41.5 137.8 8890 18520 0.35 42.0 139.4 8180 18520 0.38 42.5 141.1 8180 15870 0.32 43.0 142.7 8390 16260 0.32 43.5 144.4 7840 14810 0.31 44.0 146.0 7710 15150 0.33 44.5 147.6 8550 15500 0.28 45.0 149.3 9660 16260 0.23 45.5 150.9 9390 18020 0.31 46.0 152.6 9460 18020 0.31 46.5 154.2 8600 17090 0.33 47.0 155.8 7580 15870 0.35 47.5 157.5 7840 16670 0.36 48.0 159.1 8550 17090 0.33 48.5 160.1 8830 17090 0.32 48.8 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-106 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2940 4840 2990 5640 2900 5640 2750 5210 2800 5080 2760 5080 2820 4960 2860 5210 2820 5350 2820 4960 2920 5210 2800 5640 2990 5080 2920 5490 2750 4960 2760 5080 2760 4960 2940 5080 2640 4960 2780 5640 2820 6160 2710 5210 2710 5210 2800 4960 2820 5810 2710 5640 2490 5640 2490 4840 2560 4960 2390 4520 2350 4620 2610 4730 2940 4960 2860 5490 2880 5490 2620 5210 2310 4840 2390 5080 2610 5210 2690 5210 January 11, 2014 0.21 0.31 0.32 0.31 0.28 0.29 0.26 0.28 0.31 0.26 0.27 0.34 0.24 0.30 0.28 0.29 0.27 0.25 0.30 0.34 0.37 0.31 0.31 0.26 0.35 0.35 0.38 0.32 0.32 0.31 0.33 0.28 0.23 0.31 0.31 0.33 0.35 0.36 0.33 0.32 Page 1 04 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Nat. Gamma (CAL)

Nat. Gamma (DUIN)

Conductivity-Short Conductivity-Long Borehole Diameter Depth 0

CPS 150 ° CPS 150

-10 mS/m 30 -20 mS/m 20 2 INCH 6

Feet MP-111

~~

~

10 20

~

c.

30 JP>

~-

("

40

?-

?

r-I I ~

j 50 f=: ~

?

~

\\

I'-..

60

~

l/

/

~

po. r 70

{

< ~

r "i

~

80

~

~p r 90

)

)

~

i

)l 100

~

110

~>

~r;>

120

~

~

)

K_

130

~

140

"' ~

L5 II

)

-~

150 p~

~

160

~

~

~

( -

170 jl Figure 14. Boring MP-111, Induction, Natural Gamma and Caliper logs GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-107 of 1849 January 11, 2014 Page 1 05 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 10. Boring MP-111, Acoustic Televiewer Feature depth, dip azimuth, dip and description Depth Dip Structure Dip (feet) azimuth description 35.0 N325 59 Fracture Planar Hairline-fracture 35.1 N166 35 Primary-structure Planar Bedding 36.2 N157 43 Primary-structure Planar Bedding 36.9 N159 40 Primary-structure Planar Bedding 37.7 N331 43 Fracture Planar Open-fracture 37.7 N165 39 Primary-structure Planar Bedding 39.0 N155 35 Primary-structure Planar Bedding 40.0 N152 34 Primary-structure Planar Bedding 40.8 N329 38 Fracture Discontinuous Hairline-fracture 40.8 N159 31 Primary-structure Planar Bedding 41.5 N158 37 Primary-structure Planar Bedding 41.8 N157 83 Fracture Discontinuous Hairline-fracture 42.2 N162 35 Primary-structure Planar Bedding 42.8 N159 33 Primary-structure Planar Bedding 44.2 N162 34 Primary-structure Planar Bedding 45.3 N160 32 Primary-structure Planar Bedding 46.0 N162 33 Primary-structure Planar Bedding 46.7 N163 34 Primary-structure Planar Bedding 47.8 N157 35 Primary-structure Planar Bedding 48.6 N148 35 Primary-structure Planar Bedding 49.6 N354 49 Fracture Discontinuous Hairline-fracture 50.0 N159 34 Primary-structure Planar Bedding 51.0 N159 33 Primary-structure Planar Bedding 51.5 N337 63 Fracture Discontinuous Hairline-fracture 51.6 N166 31 Primary-structure Planar Bedding 52.0 N332 68 Fracture Discontinuous Hairline-fracture 52.2 N339 60 Fracture Discontinuous Hairline-fracture 52.7 N156 32 Primary-structure Planar Bedding 53.1 N334 50 Fracture Discontinuous Hairline-fracture 53.9 N159 34 Primary-structure Planar Bedding 54.8 N162 35 Primary-structure Planar Bedding 55.3 N162 33 Primary-structure Planar Bedding 56.0 N156 34 Primary-structure Planar Bedding 56.5 N343 52 Fracture Discontinuous Hairline-fracture 56.7 N167 35 Primary-structure Planar Bedding 57.6 N158 35 Primary-structure Planar Bedding 58.4 N156 34 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-108 of 1849 Page 1 06 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 59.0 N169 34 Primary-structure Planar Bedding 60.1 N158 32 Primary-structure Planar Bedding 60.8 N163 35 Primary-structure Planar Bedding 61.7 N170 37 Primary-structure Planar Bedding 62.1 N158 29 Primary-structure Planar Bedding 63.2 N165 37 Primary-structure Planar Bedding 64.2 N160 37 Primary-structure Planar Bedding 64.7 N156 36 Primary-structure Planar Bedding 65.9 N165 33 Primary-structure Planar Bedding 66.4 N157 37 Primary-structure Planar Bedding 66.6 N349 48 Fracture Discontinuous Hairline-fracture 67.1 N327 51 Fracture Discontinuous Hairline-fracture 67.4 N160 33 Primary-structure Planar Bedding 68.3 N163 37 Primary-structure Planar Bedding 68.8 N166 33 Primary-structure Planar Bedding 69.5 N160 40 Primary-structure Planar Bedding 69.6 N335 46 Fracture Planar Hairline-fracture 70.4 N154 29 Primary-structure Planar Bedding 71.8 N153 28 Fracture Planar Open-fracture 72.6 N165 31 Primary-structure Planar Bedding 73.0 N160 31 Primary-structure Planar Bedding 73.0 N319 71 Fracture Discontinuous Hairline-fracture 74.3 N163 33 Primary-structure Planar Bedding 75.2 N159 31 Primary-structure Planar Bedding 76.0 N164 35 Primary-structure Planar Bedding 76.7 N157 32 Primary-structure Planar Bedding 77.5 N160 35 Primary-structure Planar Bedding 78.4 N154 35 Primary-structure Planar Bedding 79.6 N161 34 Primary-structure Planar Bedding 80.4 N161 32 Primary-structure Planar Bedding 80.9 N159 34 Primary-structure Planar Bedding 81.9 N160 34 Primary-structure Planar Bedding 82.5 N160 33 Primary-structure Planar Bedding 83.6 N153 45 Primary-structure Planar Bedding 84.2 N168 46 Primary-structure Planar Bedding 85.4 N344 50 Fracture Discontinuous Hairline-fracture 85.6 N162 35 Primary-structure Planar Bedding 86.4 N339 41 Fracture Discontinuous Hairline-fracture 86.6 N147 36 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-109 of 1849 Page 1 07 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 87.1 N158 31 Primary-structure Planar Bedding 88.3 N156 32 Primary-structure Planar Bedding 89.7 N145 33 Primary-structure Planar Bedding 90.3 N167 31 Primary-structure Planar Bedding 91.3 N154 35 Primary-structure Planar Bedding 91.4 N153 29 Primary-structure Planar Bedding 92.0 N158 34 Primary-structure Planar Bedding 92.9 N161 33 Primary-structure Planar Bedding 93.3 N160 36 Primary-structure Planar Bedding 94.5 N161 30 Primary-structure Planar Bedding 94.6 N347 37 Fracture Discontinuous Hairline-fracture 95.3 N146 63 Fracture Discontinuous Hairline-fracture 95.7 N157 34 Primary-structure Planar Bedding 96.4 N154 33 Primary-structure Planar Bedding 97.2 N158 31 Primary-structure Planar Bedding 98.1 N149 34 Primary-structure Planar Bedding 98.2 N330 34 Fracture Discontinuous Hairline-fracture 99.3 N155 33 Primary-structure Planar Bedding 100.2 N152 36 Primary-structure Planar Bedding 100.9 N157 30 Primary-structure Planar Bedding 101.4 N158 35 Primary-structure Planar Bedding 102.0 N163 31 Primary-structure Planar Bedding 103.2 N144 31 Primary-structure Planar Bedding 104.2 N149 37 Primary-structure Planar Bedding 105.5 N152 27 Primary-structure Planar Bedding 106.3 N152 30 Primary-structure Planar Bedding 106.8 N153 32 Primary-structure Planar Bedding 108.0 N158 32 Primary-structure Planar Bedding 108.4 N158 32 Primary-structure Planar Bedding 108.8 N159 36 Fracture Planar Hairline-fracture 109.0 N157 33 Primary-structure Planar Bedding 109.2 N145 31 Primary-structure Planar Bedding 109.7 N158 32 Primary-structure Planar Bedding 110.5 N156 29 Primary-structure Planar Bedding 111.1 N335 48 Fracture Discontinuous Hairline-fracture 111.4 N161 26 Primary-structure Planar Bedding 112.4 N331 57 Fracture Discontinuous Hairline-fracture 112.6 N156 33 Primary-structure Planar Bedding 114.5 N149 33 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-110 of 1849 Page 1 08 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 116.2 N156 31 Primary-structure Planar Bedding 116.6 N339 55 Fracture Discontinuous Hairline-fracture 116.7 N156 30 Primary-structure Planar Bedding 117.4 N156 28 Primary-structure Planar Bedding 118.3 N160 34 Primary-structure Planar Bedding 119.6 N169 46 Primary-structure Planar Bedding 120.4 N164 36 Primary-structure Planar Bedding 120.8 N171 33 Primary-structure Planar Bedding 121.4 N151 34 Primary-structure Planar Bedding 122.1 N158 33 Primary-structure Planar Bedding 122.9 N160 32 Primary-structure Planar Bedding 123.9 N336 55 Fracture Discontinuous Hairline-fracture 124.1 N153 33 Primary-structure Planar Bedding 125.0 N157 33 Primary-structure Planar Bedding 126.0 N155 32 Primary-structure Planar Bedding 127.0 N158 29 Primary-structure Planar Bedding 127.2 N334 65 Fracture Discontinuous Hairline-fracture 127.8 N161 33 Primary-structure Planar Bedding 128.7 N152 35 Primary-structure Planar Bedding 129.3 N139 29 Primary-structure Planar Bedding 130.6 N161 35 Primary-structure Planar Bedding 131.4 N150 39 Primary-structure Planar Bedding 132.4 N159 28 Primary-structure Planar Bedding 133.3 N157 31 Primary-structure Planar Bedding 133.8 N165 50 Primary-structure Planar Bedding 135.1 N163 32 Primary-structure Planar Bedding 136.0 N160 26 Primary-structure Planar Bedding 136.6 N153 28 Primary-structure Planar Bedding 137.2 N155 25 Primary-structure Planar Bedding 138.2 N156 37 Primary-structure Planar Bedding 138.6 N335 58 Fracture Discontinuous Hairline-fracture 139.0 N148 35 Primary-structure Planar Bedding 140.3 N154 46 Primary-structure Planar Bedding 141.1 N153 46 Primary-structure Planar Bedding 142.1 N160 41 Primary-structure Planar Bedding 143.1 N156 45 Primary-structure Planar Bedding 144.5 N163 37 Primary-structure Planar Bedding 145.4 N158 35 Primary-structure Planar Bedding 146.2 N160 32 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-111 of 1849 Page 1 09 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 147.0 N160 30 Primary-structure Planar Bedding 147.9 N156 31 Primary-structure Planar Bedding 148.8 N157 47 Primary-structure Planar Bedding 150.0 N162 39 Primary-structure Planar Bedding 150.8 N142 34 Primary-structure Planar Bedding 152.1 N338 47 Fracture Discontinuous Hairline-fracture 152.2 N155 36 Primary-structure Planar Bedding 153.3 N141 43 Primary-structure Planar Bedding 153.6 N163 30 Primary-structure Planar Bedding 153.8 N161 39 Primary-structure Planar Bedding 154.5 N332 56 Fracture Discontinuous Hairline-fracture 154.8 N159 33 Primary-structure Planar Bedding 155.6 N154 37 Primary-structure Planar Bedding 156.9 N141 36 Primary-structure Planar Bedding 158.8 N151 38 Primary-structure Planar Bedding 160.5 N147 37 Primary-structure Planar Bedding 162.5 N344 40 Fracture Planar Hairline-fracture 163.0 N155 36 Primary-structure Planar Bedding 164.3 N164 37 Primary-structure Planar Bedding 164.8 N161 32 Primary-structure Planar Bedding 165.5 N159 32 Fracture Planar Open-fracture 166.3 N155 42 Primary-structure Planar Bedding 167.6 N158 32 Primary-structure Planar Bedding 169.6 N129 41 Primary-structure Planar Bedding 170.0 N147 35 Primary-structure Planar Bedding 171.3 N155 30 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-112 of 1849 Page 11 0 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC CLINCH RIVER top of borehole...

East:

Nortl}:

Alt:

Zone from 171.807 to 34.482ft Interpretation 1 Dip data sets..

BHTVdips MP-111 34.482-171.807ft Dip-azimuth, fracture rose-diagram DIP DATA INTERPRETATION RGLDIP vsn 6.2 DIP-AZIMUTH, FRACTURE ROSE-DIAGRAM Borehole: MP-111 Azimuth I ncr= 1 oo N ~ 180 MP-111, Interpretation 1 171.807 to 34.482fl North ref. is true Depth units are feet N

s AMEC Project 6468-13-1072 0

1 0 20 30 40 50 60 70 80 Figure 15. Boring MP-111, Rose Diagram GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-113 of 1849 January 11, 2014 Page 111 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N349 50 25 T --I--~ - -I ----

Borehole: MP-111 Sonde: BHTV Zone from: 0.000 to 172.868ft North ref is true Mean deviation: 1.53 to N259_36 End coordinates.

North: -0_853 East: -4.537 Down: 172.805 Azimuth of end: N259.36 Distance start-end: 4.617ft Viewpoint: N349 "0

r!

Data extrapolated to the surface from 32. 500ft

,.") *~

25J I

I 501

-1

~I 75-1 I

I 100 I

I I

I

-1 150 I

25 Figure 16. Boring MP-111, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-114 of 1849 January 11, 2014 Page 112 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 0

5 10 15 20 E.

c 1-25 a..

w c

30 35 40 45 50 0

4

\\

CLINCH RIVER SMR PROJECT BOREHOLE MP-111 PS Receiver to Receiver V5 and V P Analysis I

["....

  • r---..

.II v

I

~

\\.

~ -

r-

  • 1--.. --

v r\\.

2000 4000 I

I Near-Far Receivers, Vs Near-Far Receivers, Vp

.l

/

I

\\......

I' 6000 VELOCITY (ft/s) l I

8000 10000 12000 Figure 17: Boring MP-111 PS, Suspension R1-R2 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-115 of 1849 January 11, 2014 Page 113 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 11. Boring MP-111 PS, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-111 PS American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 6.6 390 1580 0.47 2.0 8.2 540 1660 0.44 2.5 9.8 490 1540 0.44 3.0 11.5 470 2110 0.47 3.5 13.1 390 2000 0.48 4.0 14.8 490 3170 0.49 4.5 16.4 470 3750 0.49 5.0 18.0 490 2620 0.48 5.5 19.7 410 1970 0.48 6.0 21.3 510 1900 0.46 6.5 23.0 530 2220 0.47 7.0 24.6 490 2580 0.48 7.5 26.3 630 3240 0.48 8.0 27.9 530 5210 0.49 8.5 29.5 560 5130 0.49 9.0 31.2 700 5600 0.49 9.5 32.8 740 5460 0.49 10.0 34.5 800 5130 0.49 10.5 36.1 1440 5460 0.46 11.0 37.4 1490 5900 0.47 11.4 37.7 2100 6870 0.45 11.5 39.4 4980 10100 0.34 12.0 41.0 4440 10100 0.38 12.5 42.7 4830 9950 0.35 13.0 44.3 4800 10750 0.38 13.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-116 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 120 170 150 140 120 150 140 150 120 150 160 150 190 160 170 210 220 240 440 450 640 1520 1350 1470 1460 January 11, 2014 480 510 470 640 610 970 1140 800 600 580 680 790 990 1590 1560 1710 1670 1560 1670 1800 2090 3080 3080 3030 3280 0.47 0.44 0.44 0.47 0.48 0.49 0.49 0.48 0.48 0.46 0.47 0.48 0.48 0.49 0.49 0.49 0.49 0.49 0.46 0.47 0.45 0.34 0.38 0.35 0.38 Page 114 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N24 Borehole: MP-111 PS Sonde: BHTV Zone from: 0.000 to 58.072ft North ref is true Mean deviation: 2.84 to N293.55 End coordinates..

North: 1.151 East: -2.641 Down : 58.000 Azimuth of end: N293.55 Distance start-end: 2.880ft Viewpoint: N24 Data extrapolated to the surface from 1. 712ft 25-50-Figure 18. Boring MP-111 PS, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-117 of 1849 January 11, 2014 Page 115 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 CLINCH RIVER SMR PROJECT BOREHOLE MP-112 Receiver to Receiver V5 and V P Analysis 0

20 40 60 g

80

c 1-a..

w c 100 120 140 160 180 e:jj 0

5000

~

\\.

_.1 > '

.I

  • ~~~

L 1

_..II L.e-'.-

['e-. -....

[

..A~ -

1.--r r---

l

[\\ -~

"""'IL 10000 VELOCITY (ft/s)

~ Near-Far Receivers, Vs Near-Far Receivers, Vp I~ -.

1-=::::- ~

~

ll

_. ;II

  • ~

~

..-r--

-..._ r-..

~

~

r.

  • =:::............,

LT

.r I--

T..._ -

... ~

-=:::....--

15000 20000 Figure 19: Boring MP-112, Suspension R1-R2 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-118 of 1849 January 11, 2014 Page 116 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 12. Boring MP-112, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-112 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 36.1 8490 17090 0.34 11.0 37.7 8390 16260 0.32 11.5 39.4 8180 15870 0.32 12.0 41.0 7840 15150 0.32 12.5 42.7 8950 16670 0.30 13.0 44.3 9070 16670 0.29 13.5 45.9 8660 16260 0.30 14.0 47.6 8440 16670 0.33 14.5 49.2 8280 15150 0.29 15.0 50.9 8660 16260 0.30 15.5 52.5 8710 16260 0.30 16.0 54.1 8710 15500 0.27 16.5 55.8 8890 16260 0.29 17.0 57.4 7750 15870 0.34 17.5 59.1 7660 14490 0.31 18.0 60.7 7940 15150 0.31 18.5 62.3 7940 14810 0.30 19.0 64.0 8550 15500 0.28 19.5 65.6 8890 16260 0.29 20.0 67.3 8710 15870 0.28 20.5 68.9 8180 15150 0.29 21.0 70.5 7660 13890 0.28 21.5 72.2 7800 14490 0.30 22.0 73.8 8330 14810 0.27 22.5 75.5 8660 15500 0.27 23.0 77.1 8030 14490 0.28 23.5 78.7 7290 14180 0.32 24.0 80.4 6910 13610 0.33 24.5 82.0 7490 14180 0.31 25.0 84.0 8600 15500 0.28 25.6 85.3 9260 17090 0.29 26.0 86.9 9130 18020 0.33 26.5 88.6 9070 17540 0.32 27.0 90.2 9460 17090 0.28 27.5 91.9 8770 17090 0.32 28.0 93.5 7940 15150 0.31 28.5 95.1 7530 14810 0.33 29.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-119 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2590 5210 2560 4960 2490 4840 2390 4620 2730 5080 2760 5080 2640 4960 2570 5080 2520 4620 2640 4960 2660 4960 2660 4730 2710 4960 2360 4840 2340 4420 2420 4620 2420 4520 2610 4730 2710 4960 2660 4840 2490 4620 2340 4230 2380 4420 2540 4520 2640 4730 2450 4420 2220 4320 2110 4150 2280 4320 2620 4730 2820 5210 2780 5490 2760 5350 2880 5210 2670 5210 2420 4620 2300 4520 January 11, 2014 0.34 0.32 0.32 0.32 0.30 0.29 0.30 0.33 0.29 0.30 0.30 0.27 0.29 0.34 0.31 0.31 0.30 0.28 0.29 0.28 0.29 0.28 0.30 0.27 0.27 0.28 0.32 0.33 0.31 0.28 0.29 0.33 0.32 0.28 0.32 0.31 0.33 Page 117 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-112 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 96.8 7580 14180 0.30 29.5 98.4 7800 14180 0.28 30.0 100.1 7750 14180 0.29 30.5 101.7 7660 13890 0.28 31.0 103.4 8330 14490 0.25 31.5 105.0 8950 16670 0.30 32.0 106.6 8770 15870 0.28 32.5 108.3 8710 16670 0.31 33.0 109.9 8890 17090 0.31 33.5 111.6 9260 17540 0.31 34.0 113.2 9320 18020 0.32 34.5 115.2 9320 18020 0.32 35.1 116.5 9520 17540 0.29 35.5 118.1 9070 17540 0.32 36.0 119.8 8280 17090 0.35 36.5 121.4 7620 15500 0.34 37.0 123.4 7250 14490 0.33 37.6 124.7 7250 14490 0.33 38.0 126.3 6980 13330 0.31 38.5 128.0 6770 13330 0.33 39.0 129.6 6540 13070 0.33 39.5 131.2 6840 13330 0.32 40.0 132.9 7800 14490 0.30 40.5 134.5 8490 16670 0.32 41.0 136.2 8440 16670 0.33 41.5 137.8 8660 17540 0.34 42.0 139.4 8280 16670 0.34 42.5 141.1 6670 14180 0.36 43.0 142.7 5600 11490 0.34 43.5 144.4 5980 12120 0.34 44.0 146.0 6230 12580 0.34 44.5 147.6 6320 12820 0.34 45.0 149.3 6440 13610 0.36 45.5 150.9 6770 14810 0.37 46.0 152.6 6670 13330 0.33 46.5 154.2 6200 12580 0.34 47.0 156.2 6570 13890 0.36 47.6 157.5 6840 13890 0.34 48.0 159.1 6470 13330 0.35 48.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-120 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2310 4320 2380 4320 2360 4320 2340 4230 2540 4420 2730 5080 2670 4840 2660 5080 2710 5210 2820 5350 2840 5490 2840 5490 2900 5350 2760 5350 2520 5210 2320 4730 2210 4420 2210 4420 2130 4060 2060 4060 1990 3980 2080 4060 2380 4420 2590 5080 2570 5080 2640 5350 2520 5080 2030 4320 1710 3500 1820 3690 1900 3830 1930 3910 1960 4150 2060 4520 2030 4060 1890 3830 2000 4230 2080 4230 1970 4060 January 11, 2014 0.30 0.28 0.29 0.28 0.25 0.30 0.28 0.31 0.31 0.31 0.32 0.32 0.29 0.32 0.35 0.34 0.33 0.33 0.31 0.33 0.33 0.32 0.30 0.32 0.33 0.34 0.34 0.36 0.34 0.34 0.34 0.34 0.36 0.37 0.33 0.34 0.36 0.34 0.35 Page 118 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-112 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 160.8 6410 13610 0.36 49.0 162.4 6470 13610 0.35 49.5 164.0 6500 13330 0.34 50.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-121 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 1950 4150 1970 4150 1980 4060 January 11, 2014 0.36 0.35 0.34 Page 119 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Nat. Gamma (CAL)

Nat. Gamma (DUIN)

Conductivity-Short Conductivity-Long Borehole Diameter Depth 0

CPS 150 0 CPS 150

-10 mS/m 40 -10 mS/m 40 2 INCH 6

Feet MP-112

~

1--

1--

10

-~

1---~

-at:

20 I<;

~-

  • <i

.r-

/ 1---

~ -

b 30

?

J

,-ff

1.

(

l't 40

_(

1-- ~~

0

~

I-50

<(

~

I'"

I ~

t:;

1--

13

)

)

_J 60

~-~

- ",J:-

1-- l) r- --

I(

w r-1"'--

I ~

~ r-70

  • ~

~

_(

I 1----*

- -- w -

80

\\

~-~-

?

1--

~

~

1--

- (

I(

a:l

~

I ~

90

  • ~

~

~-

\\

w 1--

1--

J

(

0

~(

100

)

I I~

~

a:l 1--

r-

<(

110

~-

_J 1-

- -- W- -


.1 >

lg;

~

""'"]

120

\\

\\

J 1--

~

0:::

w

~

130

(

/

l-5 w

2:

<(

- ~

r-~

140

)

[?

0

5 1--

- l5 w

1--

_J

~

p.

150

~-~

I<

IJ:

c::::

~

w

~

0:::

{

~

160

~)-

v I ~

1--

'("

- r-s --

170

/

- ~

1--

,.)

Figure 20. Boring MP-112, Induction, Natural Gamma and Caliper logs GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-122 of 1849 January 11, 2014 Page 120 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 13. Boring MP-112, Acoustic Televiewer Feature depth, dip azimuth, dip and description Depth Dip Structure Dip (feet) azimuth description 28.4 N148 47 Primary-structure Planar Bedding 30.3 N151 36 Primary-structure Planar Bedding 31.5 N114 28 Fracture Planar Open-fracture 32.0 N142 31 Primary-structure Planar Bedding 32.9 N142 35 Primary-structure Planar Bedding 33.9 N152 32 Primary-structure Planar Bedding 34.5 N130 40 Fracture Planar Open-fracture 34.9 N145 40 Fracture Planar Open-fracture 35.9 N153 33 Primary-structure Planar Bedding 37.1 N151 38 Primary-structure Planar Bedding 37.5 N153 37 Primary-structure Planar Bedding 38.4 N327 59 Fracture Discontinuous Hairline-fracture 38.6 N154 35 Primary-structure Planar Bedding 39.2 N146 35 Primary-structure Planar Bedding 40.4 N153 39 Primary-structure Planar Bedding 41.2 N317 45 Fracture Irregular Hairline-fracture 41.8 N153 41 Primary-structure Planar Bedding 42.3 N152 38 Primary-structure Planar Bedding 43.3 N145 33 Primary-structure Planar Bedding 44.2 N157 32 Fracture Planar Open-fracture 44.9 N158 40 Primary-structure Planar Bedding 45.2 N161 38 Primary-structure Planar Bedding 45.8 N152 37 Primary-structure Planar Bedding 46.7 N156 37 Primary-structure Planar Bedding 48.3 N156 34 Primary-structure Planar Bedding 48.5 N326 51 Fracture Discontinuous Hairline-fracture 49.4 N156 37 Primary-structure Planar Bedding 50.6 N148 36 Primary-structure Planar Bedding 51.9 N148 38 Primary-structure Planar Bedding 52.4 N148 31 Primary-structure Planar Bedding 53.4 N149 27 Primary-structure Planar Bedding 54.1 N341 38 Fracture Irregular Hairline-fracture 54.4 N158 36 Primary-structure Planar Bedding 55.3 N153 35 Primary-structure Planar Bedding 56.1 N323 49 Fracture Discontinuous Hairline-fracture 56.8 N157 38 Primary-structure Planar Bedding 57.7 N157 39 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-123 of 1849 Page 121 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 58.5 N155 37 Primary-structure Planar Bedding 59.2 N158 38 Primary-structure Planar Bedding 60.0 N149 37 Primary-structure Planar Bedding 60.8 N157 40 Primary-structure Planar Bedding 61.5 N154 39 Primary-structure Planar Bedding 62.0 N330 39 Fracture Discontinuous Hairline-fracture 62.4 N153 45 Primary-structure Planar Bedding 63.2 N150 39 Primary-structure Planar Bedding 64.2 N158 32 Primary-structure Planar Bedding 64.9 N336 46 Fracture Planar Hairline-fracture 65.1 N331 54 Fracture Discontinuous Hairline-fracture 65.5 N147 37 Primary-structure Planar Bedding 65.9 N155 39 Primary-structure Planar Bedding 66.9 N156 36 Primary-structure Planar Bedding 67.6 N157 38 Primary-structure Planar Bedding 69.0 N148 38 Primary-structure Planar Bedding 70.0 N152 33 Primary-structure Planar Bedding 71.3 N145 34 Primary-structure Planar Bedding 73.3 N157 34 Primary-structure Planar Bedding 74.1 N156 37 Primary-structure Planar Bedding 74.8 N157 35 Primary-structure Planar Bedding 76.2 N155 37 Primary-structure Planar Bedding 77.9 N150 32 Primary-structure Planar Bedding 78.6 N153 34 Primary-structure Planar Bedding 80.1 N157 35 Primary-structure Planar Bedding 80.8 N157 35 Primary-structure Planar Bedding 81.4 N154 35 Primary-structure Planar Bedding 82.9 N151 36 Primary-structure Planar Bedding 84.5 N149 31 Primary-structure Planar Bedding 88.3 N338 47 Fracture Planar Hairline-fracture 90.2 N145 29 Primary-structure Planar Bedding 92.4 N149 35 Primary-structure Planar Bedding 93.1 N155 34 Primary-structure Planar Bedding 94.6 N158 31 Primary-structure Planar Bedding 95.4 N157 33 Primary-structure Planar Bedding 96.3 N146 31 Primary-structure Planar Bedding 97.1 N151 34 Primary-structure Planar Bedding 97.7 N158 34 Primary-structure Planar Bedding 98.6 N151 34 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-124 of 1849 Page 122 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 99.4 N161 31 Primary-structure Planar Bedding 100.1 N155 34 Primary-structure Planar Bedding 101.6 N153 36 Primary-structure Planar Bedding 102.5 N153 33 Primary-structure Planar Bedding 104.3 N150 32 Primary-structure Planar Bedding 105.4 N155 33 Primary-structure Planar Bedding 105.9 N152 36 Primary-structure Planar Bedding 107.5 N156 36 Primary-structure Planar Bedding 108.6 N154 35 Primary-structure Planar Bedding 110.2 N156 40 Primary-structure Planar Bedding 111.3 N151 39 Primary-structure Planar Bedding 112.5 N159 35 Primary-structure Planar Bedding 114.6 N150 29 Primary-structure Planar Bedding 116.3 N146 31 Primary-structure Planar Bedding 118.7 N151 35 Primary-structure Planar Bedding 119.3 N319 53 Fracture Irregular Hairline-fracture 119.4 N151 38 Primary-structure Planar Bedding 120.6 N150 35 Primary-structure Planar Bedding 121.6 N150 31 Primary-structure Planar Bedding 122.9 N153 33 Primary-structure Planar Bedding 123.7 N151 35 Primary-structure Planar Bedding 125.2 N156 34 Primary-structure Planar Bedding 126.3 N150 32 Primary-structure Planar Bedding 127.8 N152 38 Primary-structure Planar Bedding 129.5 N157 36 Primary-structure Planar Bedding 130.0 N153 35 Primary-structure Planar Bedding 130.8 N158 37 Primary-structure Planar Bedding 131.5 N155 33 Primary-structure Planar Bedding 132.7 N158 37 Primary-structure Planar Bedding 134.5 N158 29 Primary-structure Planar Bedding 135.0 N155 32 Primary-structure Planar Bedding 135.8 N333 54 Fracture Planar Hairline-fracture 136.8 N160 33 Primary-structure Planar Bedding 138.0 N144 33 Primary-structure Planar Bedding 138.8 N145 32 Primary-structure Planar Bedding 139.7 N152 34 Primary-structure Planar Bedding 140.7 N324 50 Fracture Discontinuous Hairline-fracture 141.1 N150 33 Primary-structure Planar Bedding 142.0 N157 34 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-125 of 1849 Page 123 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 143.1 N153 32 Primary-structure Planar Bedding 144.8 N163 34 Primary-structure Planar Bedding 145.8 N158 33 Primary-structure Planar Bedding 147.2 N156 34 Primary-structure Planar Bedding 147.9 N148 30 Primary-structure Planar Bedding 149.2 N328 60 Fracture Planar Hairline-fracture 149.7 N149 31 Primary-structure Planar Bedding 150.7 N150 30 Primary-structure Planar Bedding 151.3 N156 32 Primary-structure Planar Bedding 151.6 N343 52 Fracture Discontinuous Hairline-fracture 152.6 N156 34 Primary-structure Planar Bedding 154.1 N157 34 Primary-structure Planar Bedding 155.1 N157 33 Primary-structure Planar Bedding 156.9 N153 30 Primary-structure Planar Bedding 158.2 N153 32 Primary-structure Planar Bedding 159.4 N150 31 Primary-structure Planar Bedding 160.4 N167 34 Primary-structure Planar Bedding 161.8 N152 38 Primary-structure Planar Bedding 163.0 N153 35 Primary-structure Planar Bedding 167.3 N162 34 Primary-structure Planar Bedding 168.3 N157 35 Primary-structure Planar Bedding 169.6 N164 34 Primary-structure Planar Bedding 170.8 N337 58 Fracture Planar Hairline-fracture 172.8 N160 33 Fracture Planar Open-fracture 173.2 N151 34 Primary-structure Planar Bedding 174.8 N155 34 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-126 of 1849 Page 124 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC CLINCH RIVER top of borehole...

East:

Nortll Alt:

Zone from 175.261 to 27.900ft Interpretation 1 Dip data sets..

BHTVdips MP-112 27.900-175.261ft Dip-azimuth, fracture rose-diagram DIP DATA INTERPRETATION RGLDIP vsn 6.2 DIP-AZIMUTH. FRACTURE ROSE-DIAGRAM w

Borehole: MP-112 Azimuth I ncr= 10° N = 141 MP-112, Interpretation 1 175.261 to 27.900fl North ref. is true Depth units are feet N

I I

s AMEC Project 6468-13-1072 E

0 10 20 30 40 50 60 70 80 90 Figure 21. Boring MP-112, Rose Diagram GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-127 of 1849 January 11, 2014 Page 125 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N136 Borehole: MP-112 Sonde: BHTV Zone from: 0.000 to 176.276ft North ref is true Mean deviation: 28.05 to N46_49 End coordinates.

North: 57_069 East: 60.110 Down: 155.571 Azimuth of end: N46.49 Distance start-end: 82.886ft Viewpoint: N136 Data extrapolated to the surface from 24.004ft Figure 22. Boring MP-112, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-128 of 1849 January 11, 2014 Page 126 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 CLINCH RIVER SMR PROJECT BOREHOLE MP-113 Receiver to Receiver V 5 and V P Analysis 0

20 40 60 g

80

c 1-a..

w c 100 120 140 160 180 e:::::::;

0

.e

!;;:t I~

~

  • r==::..

~

~

.1. ~

  • f..--lr r..

.?'

1,.

I'*

5000

-... ~

........ I

.....-====== ~

1'-e-..

~

~

- ~

1..

~ ---

r---t.. -

~

10000 VELOCITY (ft/s)

~ Near-Far Receivers, Vs Near-Far Receivers, Vp


":I 1::

~

_ll

- ~

=-

  • ~

~

.0::::: -

~....... -=--

!1 -

-...It

~

=II

~

~

15000 20000 Figure 23: Boring MP-113, Suspension R1-R2 P-and Swwave velocities GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-129 of 1849 January 11, 2014 Page 127 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 14. Boring MP-113, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-113 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 26.3 8.0 27.9 8.5 29.5 3400 10420 0.44 9.0 31.2 4630 10750 0.39 9.5 32.8 3250 11700 0.46 10.0 34.5 3970 11900 0.44 10.5 36.1 4070 13070 0.45 11.0 37.7 4390 13610 0.44 11.5 39.4 4070 14180 0.46 12.0 41.0 4270 14490 0.45 12.5 42.7 4900 13610 0.43 13.0 44.3 4190 10930 0.41 13.5 45.9 4330 12580 0.43 14.0 47.6 6170 13610 0.37 14.5 49.2 6540 15500 0.39 15.0 50.9 5950 15870 0.42 15.5 52.5 5650 13330 0.39 16.0 54.1 5170 15870 0.44 16.5 55.8 6120 13610 0.37 17.0 57.4 6730 14490 0.36 17.5 59.1 6870 14490 0.35 18.0 60.7 6170 13890 0.38 18.5 62.3 4940 13330 0.42 19.0 64.0 5900 13610 0.38 19.5 65.9 8550 16260 0.31 20.1 67.3 9130 16260 0.27 20.5 68.9 9130 18520 0.34 21.0 70.5 8550 18020 0.35 21.5 72.2 7840 15500 0.33 22.0 73.8 7490 15500 0.35 22.5 75.5 8230 16670 0.34 23.0 77.1 9130 16670 0.29 23.5 78.7 7580 15500 0.34 24.0 80.4 6670 14180 0.36 24.5 82.0 6870 15150 0.37 25.0 83.7 7580 16260 0.36 25.5 85.3 8330 15500 0.30 26.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-130 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 1040 1410 990 1210 1240 1340 1240 1300 1490 1280 1320 1880 1990 1810 1720 1580 1860 2050 2090 1880 1510 1800 2610 2780 2780 2610 2390 2280 2510 2780 2310 2030 2090 2310 2540 January 11, 2014 3180 3280 3560 3630 3980 4150 4320 4420 4150 3330 3830 4150 4730 4840 4060 4840 4150 4420 4420 4230 4060 4150 4960 4960 5640 5490 4730 4730 5080 5080 4730 4320 4620 4960 4730 0.44 0.39 0.46 0.44 0.45 0.44 0.46 0.45 0.43 0.41 0.43 0.37 0.39 0.42 0.39 0.44 0.37 0.36 0.35 0.38 0.42 0.38 0.31 0.27 0.34 0.35 0.33 0.35 0.34 0.29 0.34 0.36 0.37 0.36 0.30 Page 128 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-113 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 87.3 7940 15870 0.33 26.6 88.6 7170 14810 0.35 27.0 90.2 6940 14810 0.36 27.5 91.9 7490 15500 0.35 28.0 93.5 7750 15870 0.34 28.5 95.1 6470 14490 0.38 29.0 96.8 6060 13330 0.37 29.5 98.4 6670 15150 0.38 30.0 100.1 8230 16260 0.33 30.5 101.7 9010 16670 0.29 31.0 103.4 8770 18520 0.36 31.5 105.0 8330 17090 0.34 32.0 106.6 7490 15500 0.35 32.5 108.3 6600 13890 0.35 33.0 110.2 6670 13890 0.35 33.6 111.6 6670 14180 0.36 34.0 113.2 6800 13610 0.33 34.5 114.8 7410 15500 0.35 35.0 116.5 8330 16670 0.33 35.5 118.1 8130 17090 0.35 36.0 119.8 8660 17090 0.33 36.5 121.4 8890 18520 0.35 37.0 123.0 8770 17540 0.33 37.5 124.7 9130 17090 0.30 38.0 126.3 8770 17090 0.32 38.5 128.0 7490 16670 0.37 39.0 129.6 6730 14490 0.36 39.5 131.2 6350 13330 0.35 40.0 132.9 5950 12580 0.36 40.5 134.5 5800 13070 0.38 41.0 136.2 6540 13070 0.33 41.5 137.8 7940 16670 0.35 42.0 139.4 8130 16260 0.33 42.5 141.1 8030 15870 0.33 43.0 142.7 6120 13890 0.38 43.5 144.4 4800 12350 0.41 44.0 146.0 5170 12120 0.39 44.5 147.6 5510 12120 0.37 45.0 149.6 5600 13070 0.39 45.6 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-131 of 1849 Metric Units Velocity Poisson's Vs Vo Ratio (m/s)

(m/s) 2420 4840 2180 4520 2120 4520 2280 4730 2360 4840 1970 4420 1850 4060 2030 4620 2510 4960 2750 5080 2670 5640 2540 5210 2280 4730 2010 4230 2030 4230 2030 4320 2070 4150 2260 4730 2540 5080 2480 5210 2640 5210 2710 5640 2670 5350 2780 5210 2670 5210 2280 5080 2050 4420 1940 4060 1810 3830 1770 3980 1990 3980 2420 5080 2480 4960 2450 4840 1860 4230 1460 3760 1580 3690 1680 3690 1710 3980 January 11, 2014 0.33 0.35 0.36 0.35 0.34 0.38 0.37 0.38 0.33 0.29 0.36 0.34 0.35 0.35 0.35 0.36 0.33 0.35 0.33 0.35 0.33 0.35 0.33 0.30 0.32 0.37 0.36 0.35 0.36 0.38 0.33 0.35 0.33 0.33 0.38 0.41 0.39 0.37 0.39 Page 129 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-113 American Units Metric Units Depth at Velocity Depth at Velocity Midpoint Midpoint Between Poisson's Between Poisson's Receivers Vs Vo Ratio Receivers Vs Vo Ratio (ft)

(ft/s)

(ft/s)

(m)

(m/s)

(m/s) 150.9 6060 13330 0.37 46.0 1850 4060 0.37 152.6 5700 12120 0.36 46.5 1740 3690 0.36 154.2 5460 12580 0.38 47.0 1670 3830 0.38 155.8 5850 12820 0.37 47.5 1780 3910 0.37 157.5 5510 12820 0.39 48.0 1680 3910 0.39 159.1 5290 12820 0.40 48.5 1610 3910 0.40 160.8 5290 11900 0.38 49.0 1610 3630 0.38 162.4 5650 11490 0.34 49.5 1720 3500 0.34 164.0 6120 12820 0.35 50.0 1860 3910 0.35 Notes:

"-" means no data available at that particular interval of depth.

GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-132 of 1849 January 11, 2014 Page 130 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project Nat. Gamma (CAL)

Nat. Gamma (DUIN) 0 CPS 150 0 CPS 150 MP-113

<"t

- r- -

1-- -

-~

r--

1---

1~

~

~

f--

p

~ ?

~ p.

1-c:::

~

~

=

-= I-1-

~

~

1--- ;?=

1-c

)

~

- r-

- r-

~

J

-~

1-*

~

- ~

1-1---

":t.. ~

~

c

~

1---

- r-

~

~

~-

~-

....... t:?

"'-~

-~ ~

?

1---

~

f--

t 1---

~

'2 p:::

+-

~ -

~-

1---

~ -

j!"

~

.. ~

"~

~~

~

-:( P'-

J~

f-

....r

~---'"

~

AMEC Project 6468-13-1072 Conductivity-Short Conductivity-Long Borehole Diameter Depth

-10 mS/m 50 -10 mS/m 50 2 INCH 6

Feet 10

z -

20 0

t-

<(

z 30 I

0 z

{

40

~

)

0 50 I

I I

~

~

60 --?--

J G -

I(

t-70 Q _

80

...J Cll -

<(

90

)

)

d -

w 0::

z 100

')

)

0::

w 110 w

~

<(

120 l

~

0 -

ill d

130

-~ -~

~

(

w 140 0::

/

J 0

Cil 150

\\

\\

160

/

7 170 Figure 24. Boring MP-113, Induction, Natural Gamma and Caliper logs GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-133 of 1849 January 11, 2014 Page 131 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 15. Boring MP-113, Acoustic Televiewer Feature depth, dip azimuth, dip and description Depth Dip Structure Dip (feet) azimuth description 27.7 N158 42 Fracture Planar Open-fracture 27.9 N157 38 Fracture Planar Hairline-fracture 28.6 N155 32 Fracture Planar Open-fracture 29.2 N160 36 Primary-structure Planar Bedding 30.0 N166 36 Primary-structure Planar Bedding 30.7 N156 33 Primary-structure Planar Bedding 31.1 N345 52 Fracture Discontinuous Hairline-fracture 31.3 N164 34 Primary-structure Planar Bedding 31.5 N158 50 Fracture Planar Open-fracture 32.6 N161 37 Primary-structure Planar Bedding 33.2 N145 36 Primary-structure Planar Bedding 34.0 N162 56 Fracture Planar Hairline-fracture 36.0 N167 34 Primary-structure Planar Bedding 36.9 N155 37 Primary-structure Planar Bedding 38.7 N159 33 Primary-structure Planar Bedding 39.2 N159 37 Primary-structure Planar Bedding 39.8 N149 40 Primary-structure Planar Bedding 43.2 N142 33 Primary-structure Planar Bedding 45.8 N153 89 Fracture Discontinuous Hairline-fracture 46.1 N156 23 Fracture Planar Hairline-fracture 46.5 N164 46 Primary-structure Planar Bedding 47.8 N154 30 Primary-structure Planar Bedding 50.2 N152 36 Primary-structure Planar Bedding 50.8 N156 29 Primary-structure Planar Bedding 51.1 N153 26 Primary-structure Planar Bedding 53.1 N159 31 Primary-structure Planar Bedding 53.6 N326 73 Fracture Discontinuous Hairline-fracture 55.0 N156 26 Primary-structure Planar Bedding 58.7 N160 22 Primary-structure Planar Bedding 63.0 N141 25 Primary-structure Planar Bedding 70.1 N154 32 Primary-structure Planar Bedding 73.9 N163 33 Primary-structure Planar Bedding 80.7 N155 29 Primary-structure Planar Bedding 82.4 N156 30 Primary-structure Planar Bedding 83.1 N159 28 Primary-structure Planar Bedding 84.2 N149 26 Primary-structure Planar Bedding 91.7 N153 35 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-134 of 1849 Page 132 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 92.0 N336 40 Fracture Discontinuous Hairline-fracture 96.1 N150 26 Primary-structure Planar Bedding 96.8 N149 28 Primary-structure Planar Bedding 98.2 N147 30 Primary-structure Planar Bedding 100.0 N158 27 Primary-structure Planar Bedding 102.3 N342 42 Fracture Discontinuous Hairline-fracture 104.9 N340 54 Fracture Discontinuous Hairline-fracture 105.4 N330 48 Fracture Planar Hairline-fracture 112.3 N152 25 Primary-structure Planar Bedding 116.1 N155 23 Primary-structure Planar Bedding 122.3 N147 25 Primary-structure Planar Bedding 134.8 N360 43 Fracture Discontinuous Hairline-fracture 135.2 N160 34 Primary-structure Planar Bedding 136.1 N146 24 Primary-structure Planar Bedding 141.5 N314 45 Fracture Irregular Hairline-fracture 142.2 N327 41 Fracture Planar Hairline-fracture 151.6 N160 16 Primary-structure Planar Bedding 153.4 N155 30 Primary-structure Planar Bedding 159.3 N162 21 Primary-structure Planar Bedding 168.3 N154 26 Fracture Planar Open-fracture 172.6 N149 25 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-135 of 1849 Page 133 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC CLINCH RIVER top of borehole...

East:

Norttr Alt:

Zone from 173.143 to 27.197ft Interpretation 1 Dip data sets..

BHTVdips MP-113 27.197-173.143ft Dip-azimuth, fracture rose-diagram DIP DATA INTERPRETATION RGLDIP vsn 6.2 DIP-AZIMUTH. FRACTURE ROSE-DIAGRAM w

Borehole: MP-113 Azimuth I ncr= 10° N =58 MP-113, Interpretation 1 173.143 to 27.197fl North ref. is true Depth units are feet N

I I

s 0

5 AMEC Project 6468-13-1072 E

10 15 20 25 Figure 25. Boring MP-113, Rose Diagram GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-136 of 1849 January 11, 2014 Page 134 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Deviated borehole in orthographic projection, viewed from N53 Borehole: MP-113 Sonde: BHTV Zone from: 0.000 to 177. 120ft North ref is true Mean deviation: 27.95 to N322_57 End coordinates.

North: 65_916 East : -50.450 Down : 156.462 Azimuth of end: N322.57 Distance start-end: 83.007ft Viewpoint: N53 Data extrapolated to the surface from 24.936ft 25 50 75-100 125 150 Figure 26. Boring MP-113, Up Deviation Projection GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-137 of 1849 January 11, 2014 Page 135 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 0

50 100 150

c 1-a..

w c

200 250 300 350 0

CLINCH RIVER SMR PROJECT BOREHOLE MP-120 Receiver to Receiver V5 and VP Analysis I

I I

Near-Far Receivers, Vs Near-Far Receivers, Vp

~

FP l..!lb..

II:

~ ~

=--

-=....

~

--~*

.. b

~

I~

......... :II

~ '

~

  • £..._ -

... L

.__ l

-==--

--.::;.~

........ ~

I!.

.. ~

IIIC: !!!..

~~

--: ~

~

~..

.. ~

J r.-

-;: ~

l ~

lid!: b

~*

-~*

-" ~

--t= -

4t:!

lll!ii5:

  • ~ -

4~

  • -=-

r

  • rfll
  • r g

l ~t

.J; ii 4; -.....

IE ~

I<<

~ -

u:

41...

-==-

~

... 1"1 5000 10000 15000 20000 VELOCITY (ft/s)

Figure 27: Boring MP-120, Suspension R1-R2 P-and Swwave velocities f--

f--

f--

25000 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 136 of 1847 RCN: CRP-111 0.0 Page C1-138 of 1849

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 16. Boring MP-120, Suspension R1-R2 depths and P-and SH-wave velocities Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-120 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 27.9 4440 8770 0.33 8.5 29.5 4730 9950 0.35 9.0 31.2 5850 13330 0.38 9.5 32.8 7020 13330 0.31 10.0 34.5 6470 13890 0.36 10.5 36.1 5510 11490 0.35 11.0 37.7 5090 11490 0.38 11.5 39.4 5050 11490 0.38 12.0 41.0 7210 13890 0.32 12.5 42.7 7490 14490 0.32 13.0 44.3 7410 14810 0.33 13.5 45.9 6290 12820 0.34 14.0 47.6 5580 12580 0.38 14.5 49.2 6010 13330 0.37 15.0 50.9 7840 13610 0.25 15.5 52.5 9200 16260 0.26 16.0 54.1 9460 19610 0.35 16.5 55.8 9520 19610 0.35 17.0 57.4 9010 17540 0.32 17.5 59.1 8890 17540 0.33 18.0 60.7 8600 16670 0.32 18.5 62.3 8600 16670 0.32 19.0 64.0 8830 17090 0.32 19.5 65.6 9010 18020 0.33 20.0 67.3 8830 16670 0.30 20.5 68.9 7840 14180 0.28 21.0 70.5 7620 13070 0.24 21.5 72.2 8080 13890 0.24 22.0 73.8 8660 16260 0.30 22.5 75.5 8950 17540 0.32 23.0 77.1 8390 18020 0.36 23.5 78.7 7210 15500 0.36 24.0 80.4 8550 15870 0.30 24.5 82.0 8890 16260 0.29 25.0 83.7 6980 15870 0.38 25.5 85.6 6940 15150 0.37 26.1 86.9 6290 13070 0.35 26.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-139 of 1849 Metric Units Velocity Vs (m/s) 1350 1440 1780 2140 1970 1680 1550 1540 2200 2280 2260 1920 1700 1830 2390 2800 2880 2900 2750 2710 2620 2620 2690 2750 2690 2390 2320 2460 2640 2730 2560 2200 2610 2710 2130 2120 1920 January 11, 2014 Poisson's Vo Ratio (m/s) 2670 0.33 3030 0.35 4060 0.38 4060 0.31 4230 0.36 3500 0.35 3500 0.38 3500 0.38 4230 0.32 4420 0.32 4520 0.33 3910 0.34 3830 0.38 4060 0.37 4150 0.25 4960 0.26 5980 0.35 5980 0.35 5350 0.32 5350 0.33 5080 0.32 5080 0.32 5210 0.32 5490 0.33 5080 0.30 4320 0.28 3980 0.24 4230 0.24 4960 0.30 5350 0.32 5490 0.36 4730 0.36 4840 0.30 4960 0.29 4840 0.38 4620 0.37 3980 0.35 Page 137 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-120 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 88.6 6570 13610 0.35 27.0 90.2 7660 14810 0.32 27.5 91.9 8770 16260 0.29 28.0 93.5 9200 18020 0.32 28.5 95.1 9200 17540 0.31 29.0 96.8 9010 18020 0.33 29.5 98.4 7890 17090 0.36 30.0 100.1 7130 14490 0.34 30.5 101.7 7050 14180 0.34 31.0 103.4 7330 13890 0.31 31.5 105.0 7290 14180 0.32 32.0 106.6 7330 14180 0.32 32.5 108.3 8080 15150 0.30 33.0 109.9 8710 16260 0.30 33.5 111.6 8440 16260 0.32 34.0 113.2 8660 16260 0.30 34.5 114.8 9130 17090 0.30 35.0 116.5 9260 17090 0.29 35.5 118.1 9200 17090 0.30 36.0 119.8 9520 18020 0.31 36.5 121.4 9320 18020 0.32 37.0 123.0 7940 16260 0.34 37.5 124.7 7290 15870 0.37 38.0 126.3 6870 13890 0.34 38.5 128.0 6700 13070 0.32 39.0 129.6 6410 13610 0.36 39.5 131.2 6470 13070 0.34 40.0 133.2 7250 14490 0.33 40.6 134.8 8080 14810 0.29 41.1 136.2 8180 15150 0.29 41.5 137.8 7940 14490 0.29 42.0 139.4 7710 15500 0.34 42.5 141.1 6500 13610 0.35 43.0 143.0 5510 10100 0.29 43.6 144.4 5770 10420 0.28 44.0 146.0 6030 12120 0.34 44.5 147.6 6260 11300 0.28 45.0 149.3 6470 12350 0.31 45.5 150.9 6170 12820 0.35 46.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-140 of 1849 Metric Units Velocity Vs (m/s) 2000 2340 2670 2800 2800 2750 2400 2170 2150 2230 2220 2230 2460 2660 2570 2640 2780 2820 2800 2900 2840 2420 2220 2090 2040 1950 1970 2210 2460 2490 2420 2350 1980 1680 1760 1840 1910 1970 1880 January 11, 2014 Poisson's Vo Ratio (m/s) 4150 0.35 4520 0.32 4960 0.29 5490 0.32 5350 0.31 5490 0.33 5210 0.36 4420 0.34 4320 0.34 4230 0.31 4320 0.32 4320 0.32 4620 0.30 4960 0.30 4960 0.32 4960 0.30 5210 0.30 5210 0.29 5210 0.30 5490 0.31 5490 0.32 4960 0.34 4840 0.37 4230 0.34 3980 0.32 4150 0.36 3980 0.34 4420 0.33 4520 0.29 4620 0.29 4420 0.29 4730 0.34 4150 0.35 3080 0.29 3180 0.28 3690 0.34 3440 0.28 3760 0.31 3910 0.35 Page 138 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-120 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 152.6 5930 11490 0.32 46.5 154.2 6120 12350 0.34 47.0 155.8 6260 12580 0.34 47.5 157.5 5980 11900 0.33 48.0 159.1 6030 12580 0.35 48.5 160.8 6170 13070 0.36 49.0 162.4 6230 13890 0.37 49.5 164.0 6630 15500 0.39 50.0 165.7 7020 14490 0.35 50.5 167.3 6350 13070 0.35 51.0 169.0 6500 12820 0.33 51.5 170.6 7890 17090 0.36 52.0 172.2 7890 17090 0.36 52.5 173.9 8180 16670 0.34 53.0 175.5 8490 18020 0.36 53.5 177.2 7370 19050 0.41 54.0 178.8 7410 14810 0.33 54.5 180.5 8890 15500 0.26 55.0 182.1 9800 16670 0.24 55.5 183.7 9390 17540 0.30 56.0 185.4 8830 18020 0.34 56.5 187.0 8950 16670 0.30 57.0 188.7 8890 16670 0.30 57.5 190.3 8660 16670 0.32 58.0 191.9 8890 16670 0.30 58.5 193.6 9320 17090 0.29 59.0 195.2 9590 18020 0.30 59.5 196.9 8950 16670 0.30 60.0 198.5 8950 16260 0.28 60.5 200.1 8950 17540 0.32 61.0 201.8 8830 17540 0.33 61.5 203.4 9390 19050 0.34 62.0 205.4 10100 19050 0.30 62.6 206.7 9660 17540 0.28 63.0 208.3 9010 15500 0.25 63.5 210.0 8600 14490 0.23 64.0 211.6 9070 17090 0.30 64.5 213.3 9390 18520 0.33 65.0 214.9 9390 17090 0.28 65.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-141 of 1849 Metric Units Velocity Vs (m/s) 1810 1860 1910 1820 1840 1880 1900 2020 2140 1940 1980 2400 2400 2490 2590 2250 2260 2710 2990 2860 2690 2730 2710 2640 2710 2840 2920 2730 2730 2730 2690 2860 3080 2940 2750 2620 2760 2860 2860 January 11, 2014 Poisson's Vo Ratio (m/s) 3500 0.32 3760 0.34 3830 0.34 3630 0.33 3830 0.35 3980 0.36 4230 0.37 4730 0.39 4420 0.35 3980 0.35 3910 0.33 5210 0.36 5210 0.36 5080 0.34 5490 0.36 5810 0.41 4520 0.33 4730 0.26 5080 0.24 5350 0.30 5490 0.34 5080 0.30 5080 0.30 5080 0.32 5080 0.30 5210 0.29 5490 0.30 5080 0.30 4960 0.28 5350 0.32 5350 0.33 5810 0.34 5810 0.30 5350 0.28 4730 0.25 4420 0.23 5210 0.30 5640 0.33 5210 0.28 Page 139 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-120 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 216.5 8770 17090 0.32 66.0 218.2 8390 15870 0.31 66.5 219.8 8550 14810 0.25 67.0 221.5 8830 17090 0.32 67.5 223.1 8950 16260 0.28 68.0 224.7 8030 17090 0.36 68.5 226.4 7890 15150 0.31 69.0 228.0 8130 14810 0.28 69.5 229.7 8890 16260 0.29 70.0 231.3 8710 16670 0.31 70.5 232.9 8030 15870 0.33 71.0 234.6 7940 15870 0.33 71.5 236.2 8180 15870 0.32 72.0 237.9 8660 18020 0.35 72.5 239.5 8950 17540 0.32 73.0 241.1 8950 17540 0.32 73.5 242.8 8950 17090 0.31 74.0 244.4 8950 17090 0.31 74.5 246.1 8330 17090 0.34 75.0 247.7 7370 14810 0.34 75.5 249.3 7210 15150 0.35 76.0 251.0 7330 14810 0.34 76.5 252.6 7410 14810 0.33 77.0 254.3 7660 14490 0.31 77.5 255.9 7750 14810 0.31 78.0 257.6 8710 17090 0.32 78.5 259.2 10260 18520 0.28 79.0 260.8 9520 19050 0.33 79.5 262.5 8770 17090 0.32 80.0 264.1 9260 16670 0.28 80.5 265.8 9950 18020 0.28 81.0 267.4 9800 19610 0.33 81.5 269.0 9320 16670 0.27 82.0 270.7 9660 18520 0.31 82.5 272.3 9260 18020 0.32 83.0 274.0 8890 18520 0.35 83.5 275.6 9130 16670 0.29 84.0 277.2 9200 18520 0.34 84.5 278.9 9130 17540 0.31 85.0 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-142 of 1849 Metric Units Velocity Vs (m/s) 2670 2560 2610 2690 2730 2450 2400 2480 2710 2660 2450 2420 2490 2640 2730 2730 2730 2730 2540 2250 2200 2230 2260 2340 2360 2660 3130 2900 2670 2820 3030 2990 2840 2940 2820 2710 2780 2800 2780 January 11, 2014 Poisson's Vo Ratio (m/s) 5210 0.32 4840 0.31 4520 0.25 5210 0.32 4960 0.28 5210 0.36 4620 0.31 4520 0.28 4960 0.29 5080 0.31 4840 0.33 4840 0.33 4840 0.32 5490 0.35 5350 0.32 5350 0.32 5210 0.31 5210 0.31 5210 0.34 4520 0.34 4620 0.35 4520 0.34 4520 0.33 4420 0.31 4520 0.31 5210 0.32 5640 0.28 5810 0.33 5210 0.32 5080 0.28 5490 0.28 5980 0.33 5080 0.27 5640 0.31 5490 0.32 5640 0.35 5080 0.29 5640 0.34 5350 0.31 Page 140 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Summary of Compressional Wave Velocity, Shear Wave Velocity, and Poisson's Ratio Based on Receiver-to-Receiver Travel Time Data - Borehole MP-120 American Units Depth at Velocity Depth at Midpoint Midpoint Between Poisson's Between Receivers Vs Vo Ratio Receivers (ft)

(ft/s)

(ft/s)

(m) 280.5 9390 18020 0.31 85.5 282.2 9730 20200 0.35 86.0 283.8 9520 19610 0.35 86.5 285.4 9320 19610 0.35 87.0 287.1 10030 20200 0.34 87.5 288.7 9880 19050 0.32 88.0 290.4 10030 18520 0.29 88.5 292.0 9730 20200 0.35 89.0 293.6 9520 17540 0.29 89.5 295.3 9730 18520 0.31 90.0 296.9 10030 17540 0.26 90.5 298.6 10260 20830 0.34 91.0 300.2 10420 19610 0.30 91.5 301.8 10100 18520 0.29 92.0 303.5 9520 19610 0.35 92.5 305.1 9260 17090 0.29 93.0 306.8 9520 18020 0.31 93.5 308.4 10030 18520 0.29 94.0 310.0 10260 20200 0.33 94.5 311.7 9950 19610 0.33 95.0 313.3 9520 19610 0.35 95.5 315.0 9800 19610 0.33 96.0 316.6 10340 19050 0.29 96.5 318.2 10580 21510 0.34 97.0 319.9 10580 20830 0.33 97.5 321.5 10580 20200 0.31 98.0 323.2 10180 20830 0.34 98.5 324.8 9800 19050 0.32 99.0 326.4 9660 17540 0.28 99.5 328.1 9800 18520 0.31 100.0 329.7 9950 18520 0.30 100.5 331.4 9950 18520 0.30 101.0 333.0 10030 18520 0.29 101.5 334.7 10340 19610 0.31 102.0 336.3 10500 19610 0.30 102.5 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-143 of 1849 Metric Units Velocity Vs (m/s) 2860 2970 2900 2840 3060 3010 3060 2970 2900 2970 3060 3130 3180 3080 2900 2820 2900 3060 3130 3030 2900 2990 3150 3230 3230 3230 3100 2990 2940 2990 3030 3030 3060 3150 3200 January 11, 2014 Poisson's Vo Ratio (m/s) 5490 0.31 6160 0.35 5980 0.35 5980 0.35 6160 0.34 5810 0.32 5640 0.29 6160 0.35 5350 0.29 5640 0.31 5350 0.26 6350 0.34 5980 0.30 5640 0.29 5980 0.35 5210 0.29 5490 0.31 5640 0.29 6160 0.33 5980 0.33 5980 0.35 5980 0.33 5810 0.29 6550 0.34 6350 0.33 6160 0.31 6350 0.34 5810 0.32 5350 0.28 5640 0.31 5640 0.30 5640 0.30 5640 0.29 5980 0.31 5980 0.30 Page 141 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project Nat. Gamma (CAL)

Nat. Gamma (DUIN) 0 CPS 150 0 CPS 150 MP-120

~

~

~

~

11 ~*

~

.c::

.,;p;loo..

~

-~

~

~

~

~

~

~

-r--I",.

~

lr r""

I~

s

~

=

~

I ~.

f.!.

I*"

~

I~

-::: ~

Is

~

p

~

5

g.

-"'~

p 4~

... ~

~

I~

~

D i:::

~

~

~

c..;,7

.c: p

~~ fp t

~

-..... ~

~~-

r

'?>

~

}

.i" AMEC Project 6468-13-1072 Conductivity-Short Conductivity-Long Borehole Diameter Depth

-10 mS/m 40 -20 mS/m 30 2 INCH 6

Feet Conductivity-Short#2 Conductivity-Long#2

-10 mS/m 40 -20 mS/m 30 10 20 30

~ -

~

40 50

  • - '\\.

P,*

\\

60 1\\

70 IZ.

~

80 90 c

c 100 110

!j

{J 120 -

'r-.

130 c::

c 140 v

7 150

-~

~-

~

160

~

v 170 j

180 I ~

~

190

~

~

200

~

210 220

~

\\

230

)

240 250

~~

'-)

1,.-'

,...s' 260 v

I 270 280 290 300 310 320 330 340 Figure 28. Boring MP-120, Induction, Natural Gamma and Caliper logs GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-144 of 1849 January 11, 2014 Page 142 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Table 17. Boring MP-120, Acoustic Televiewer Feature depth, dip azimuth, dip and description Depth Dip Structure Dip (feet) azimuth description 26.0 N355 61 Fracture Planar Hairline-fracture 26.8 N145 42 Primary-structure Planar Bedding 27.7 N167 37 Primary-structure Planar Bedding 29.0 N162 31 Primary-structure Planar Bedding 30.2 N175 38 Primary-structure Planar Bedding 30.9 N174 36 Primary-structure Planar Bedding 31.9 N153 33 Primary-structure Planar Bedding 32.8 N345 54 Fracture Planar Hairline-fracture 33.3 N167 32 Primary-structure Planar Bedding 33.5 N168 28 Primary-structure Planar Bedding 33.6 N334 47 Fracture Planar Hairline-fracture 34.3 N168 32 Primary-structure Planar Bedding 34.5 N160 32 Primary-structure Planar Bedding 34.5 N356 57 Fracture Planar Hairline-fracture 35.7 N181 35 Primary-structure Planar Bedding 35.8 N345 69 Fracture Planar Hairline-fracture 36.8 N320 58 Fracture Discontinuous Hairline-fracture 37.0 N149 31 Primary-structure Planar Bedding 37.2 N325 68 Fracture Discontinuous Hairline-fracture 38.0 N323 56 Fracture Discontinuous Hairline-fracture 38.0 N165 28 Primary-structure Planar Bedding 38.3 N148 38 Primary-structure Planar Bedding 39.2 N156 29 Primary-structure Planar Bedding 40.0 N335 55 Fracture Discontinuous Hairline-fracture 40.0 N156 31 Primary-structure Planar Bedding 40.6 N146 31 Primary-structure Planar Bedding 41.0 N143 32 Primary-structure Planar Bedding 41.5 N326 66 Fracture Discontinuous Hairline-fracture 41.8 N160 30 Primary-structure Planar Bedding 43.0 N157 28 Primary-structure Planar Bedding 43.8 N151 31 Primary-structure Planar Bedding 44.0 N333 41 Fracture Discontinuous Hairline-fracture 44.7 N143 34 Primary-structure Planar Bedding 45.7 N153 33 Primary-structure Planar Bedding 46.5 N150 34 Primary-structure Planar Bedding 47.2 N155 32 Primary-structure Planar Bedding 48.0 N321 65 Fracture Discontinuous Hairline-fracture GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-145 of 1849 Page 143 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 48.3 N156 29 Fracture Planar Open-fracture 48.4 N154 31 Primary-structure Planar Bedding 48.7 N150 36 Primary-structure Planar Bedding 49.8 N146 29 Primary-structure Planar Bedding 50.8 N159 36 Primary-structure Planar Bedding 52.8 N152 35 Primary-structure Planar Bedding 54.9 N147 31 Primary-structure Planar Bedding 56.7 N156 30 Primary-structure Planar Bedding 57.8 N151 30 Primary-structure Planar Bedding 59.0 N153 29 Primary-structure Planar Bedding 60.5 N155 33 Primary-structure Planar Bedding 61.3 N146 31 Primary-structure Planar Bedding 61.9 N145 28 Primary-structure Planar Bedding 62.6 N152 32 Primary-structure Planar Bedding 63.9 N149 31 Primary-structure Planar Bedding 64.5 N158 34 Primary-structure Planar Bedding 65.6 N155 31 Primary-structure Planar Bedding 66.2 N152 26 Primary-structure Planar Bedding 66.8 N157 35 Primary-structure Planar Bedding 68.1 N152 28 Primary-structure Planar Bedding 68.7 N157 33 Primary-structure Planar Bedding 69.0 N152 36 Primary-structure Planar Bedding 69.7 N146 34 Primary-structure Planar Bedding 70.2 N155 35 Primary-structure Planar Bedding 71.3 N152 31 Primary-structure Planar Bedding 71.8 N150 37 Primary-structure Planar Bedding 72.8 N150 36 Primary-structure Planar Bedding 73.9 N159 36 Primary-structure Planar Bedding 75.0 N333 49 Fracture Discontinuous Hairline-fracture 75.2 N149 31 Primary-structure Planar Bedding 75.7 N316 34 Fracture Irregular Hairline-fracture 76.8 N333 51 Fracture Discontinuous Hairline-fracture 76.9 N147 32 Primary-structure Planar Bedding 77.7 N151 39 Primary-structure Planar Bedding 78.1 N155 37 Primary-structure Planar Bedding 78.8 N159 32 Primary-structure Planar Bedding 79.2 N149 34 Primary-structure Planar Bedding 79.3 N342 41 Fracture Discontinuous Hairline-fracture 80.1 N155 35 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-146 of 1849 Page 144 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 80.2 N336 50 Fracture Discontinuous Hairline-fracture 81.8 N145 31 Primary-structure Planar Bedding 83.1 N154 31 Primary-structure Planar Bedding 84.5 N158 34 Primary-structure Planar Bedding 85.1 N150 32 Primary-structure Planar Bedding 86.3 N159 35 Primary-structure Planar Bedding 87.7 N150 34 Primary-structure Planar Bedding 88.2 N151 34 Primary-structure Planar Bedding 88.8 N152 35 Primary-structure Planar Bedding 89.7 N156 36 Primary-structure Planar Bedding 91.1 N157 39 Primary-structure Planar Bedding 93.8 N162 35 Primary-structure Planar Bedding 95.6 N331 45 Fracture Irregular Hairline-fracture 96.2 N158 34 Primary-structure Planar Bedding 97.6 N146 32 Primary-structure Planar Bedding 98.4 N332 48 Fracture Planar Hairline-fracture 98.5 N162 31 Primary-structure Planar Bedding 99.7 N153 29 Primary-structure Planar Bedding 100.6 N162 31 Primary-structure Planar Bedding 101.9 N151 39 Primary-structure Planar Bedding 102.7 N162 36 Primary-structure Planar Bedding 103.4 N148 30 Primary-structure Planar Bedding 105.0 N151 31 Primary-structure Planar Bedding 107.0 N152 34 Primary-structure Planar Bedding 107.5 N155 33 Primary-structure Planar Bedding 109.5 N156 32 Primary-structure Planar Bedding 111.3 N160 34 Primary-structure Planar Bedding 112.1 N158 34 Primary-structure Planar Bedding 113.0 N146 33 Primary-structure Planar Bedding 114.8 N158 34 Primary-structure Planar Bedding 115.7 N147 29 Primary-structure Planar Bedding 117.0 N156 37 Primary-structure Planar Bedding 118.4 N156 39 Primary-structure Planar Bedding 119.9 N335 50 Fracture Irregular Hairline-fracture 120.3 N329 40 Fracture Planar Hairline-fracture 121.7 N164 32 Fracture Planar Hairline-fracture 122.7 N156 35 Primary-structure Planar Bedding 123.8 N160 31 Primary-structure Planar Bedding 124.5 N160 33 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-147 of 1849 Page 145 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 125.2 N154 32 Primary-structure Planar Bedding 126.3 N156 32 Primary-structure Planar Bedding 127.2 N155 33 Primary-structure Planar Bedding 127.9 N149 28 Primary-structure Planar Bedding 128.6 N161 36 Primary-structure Planar Bedding 129.3 N164 36 Primary-structure Planar Bedding 130.1 N165 38 Primary-structure Planar Bedding 130.8 N166 46 Primary-structure Planar Bedding 131.8 N166 30 Primary-structure Planar Bedding 132.4 N162 35 Primary-structure Planar Bedding 134.3 N151 30 Primary-structure Planar Bedding 135.0 N314 68 Fracture Planar Hairline-fracture 135.3 N152 31 Primary-structure Planar Bedding 135.8 N148 34 Primary-structure Planar Bedding 136.6 N328 50 Fracture Discontinuous Hairline-fracture 136.8 N149 33 Primary-structure Planar Bedding 137.7 N151 31 Primary-structure Planar Bedding 138.3 N139 36 Primary-structure Planar Bedding 138.4 N325 45 Fracture Discontinuous Hairline-fracture 139.1 N327 49 Fracture Discontinuous Hairline-fracture 139.2 N136 33 Primary-structure Planar Bedding 140.0 N153 33 Primary-structure Planar Bedding 140.8 N154 31 Primary-structure Planar Bedding 141.8 N147 29 Primary-structure Planar Bedding 142.5 N156 31 Primary-structure Planar Bedding 143.6 N155 34 Primary-structure Planar Bedding 144.9 N157 35 Primary-structure Planar Bedding 145.5 N154 30 Primary-structure Planar Bedding 146.5 N159 31 Primary-structure Planar Bedding 147.4 N146 35 Primary-structure Planar Bedding 148.8 N156 31 Primary-structure Planar Bedding 148.9 N328 59 Fracture Planar Hairline-fracture 149.3 N152 36 Primary-structure Planar Bedding 149.9 N328 55 Fracture Planar Hairline-fracture 150.0 N152 27 Primary-structure Planar Bedding 150.8 N156 31 Primary-structure Planar Bedding 152.0 N152 34 Primary-structure Planar Bedding 153.1 N157 31 Primary-structure Planar Bedding 153.8 N148 32 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-148 of 1849 Page 146 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 154.3 N339 57 Fracture Discontinuous Hairline-fracture 154.3 N150 28 Primary-structure Planar Bedding 156.5 N148 29 Primary-structure Planar Bedding 157.1 N145 29 Primary-structure Planar Bedding 158.0 N159 31 Primary-structure Planar Bedding 160.3 N156 26 Primary-structure Planar Bedding 161.2 N169 32 Primary-structure Planar Bedding 161.9 N150 33 Primary-structure Planar Bedding 163.5 N160 31 Primary-structure Planar Bedding 164.6 N154 33 Primary-structure Planar Bedding 165.0 N152 34 Primary-structure Planar Bedding 165.4 N150 34 Primary-structure Planar Bedding 166.3 N161 33 Primary-structure Planar Bedding 166.9 N152 29 Primary-structure Planar Bedding 167.1 N339 50 Fracture Discontinuous Hairline-fracture 167.8 N147 40 Primary-structure Planar Bedding 168.8 N146 35 Fracture Planar Open-fracture 168.9 N156 36 Fracture Planar Open-fracture 169.1 N155 31 Primary-structure Planar Bedding 171.3 N152 32 Primary-structure Planar Bedding 172.2 N150 33 Primary-structure Planar Bedding 172.8 N153 31 Primary-structure Planar Bedding 174.0 N153 30 Primary-structure Planar Bedding 174.9 N148 31 Primary-structure Planar Bedding 175.9 N151 34 Primary-structure Planar Bedding 176.7 N157 31 Primary-structure Planar Bedding 177.7 N153 31 Primary-structure Planar Bedding 178.7 N145 35 Primary-structure Planar Bedding 180.3 N154 34 Primary-structure Planar Bedding 182.0 N152 30 Primary-structure Planar Bedding 183.4 N144 41 Primary-structure Irregular Bedding 184.7 N162 29 Primary-structure Planar Bedding 186.2 N154 29 Primary-structure Planar Bedding 187.0 N154 33 Primary-structure Planar Bedding 187.4 N163 28 Primary-structure Planar Bedding 187.8 N335 60 Fracture Discontinuous Hairline-fracture 188.2 N149 32 Primary-structure Planar Bedding 188.6 N137 46 Primary-structure Planar Bedding 189.6 N155 29 Primary-structure Planar Bedding GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-149 of 1849 Page 147 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072 Depth Dip Structure Dip (feet) azimuth description 190.3 N161 31 Primary-structure Planar Bedding 191.2 N159 41 Primary-structure Planar Bedding 191.6 N330 72 Fracture Discontinuous Hairline-fracture 192.5 N156 30 Primary-structure Planar Bedding 193.6 N161 30 Primary-structure Planar Bedding 195.7 N152 34 Primary-structure Planar Bedding 196.6 N150 30 Primary-structure Planar Bedding 197.6 N149 35 Primary-structure Planar Bedding 198.2 N152 34 Primary-structure Planar Bedding 199.4 N159 27 Primary-structure Planar Bedding 200.3 N159 34 Primary-structure Planar Bedding 201.4 N160 36 Primary-structure Planar Bedding 201.9 N156 33 Primary-structure Planar Bedding 202.8 N161 32 Primary-structure Planar Bedding 203.7 N162 31 Primary-structure Planar Bedding 204.6 N160 33 Primary-structure Planar Bedding 205.2 N154 29 Primary-structure Planar Bedding 206.0 N153 31 Primary-structure Planar Bedding 206.1 N324 53 Fracture Discontinuous Hairline-fracture 207.1 N158 32 Primary-structure Planar Bedding 211.1 N318 52 Fracture Planar Hairline-fracture 211.7 N151 33 Primary-structure Planar Bedding 212.7 N153 36 Primary-structure Planar Bedding 213.3 N158 30 Primary-structure Planar Bedding 213.9 N154 33 Primary-structure Planar Bedding 214.1 N164 40 Primary-structure Planar Bedding 215.1 N156 32 Primary-structure Planar Bedding 215.7 N321 52 Fracture Discontinuous Hairline-fracture 217.2 N148 35 Primary-structure Planar Bedding 219.6 N156 35 Primary-structure Planar Bedding 220.0 N151 29 Primary-structure Planar Bedding 220.5 N161 32 Primary-structure Planar Bedding 221.4 N155 33 Primary-structure Planar Bedding 222.4 N152 30 Primary-structure Planar Bedding 223.6 N153 33 Primary-structure Planar Bedding 224.5 N156 27 Primary-structure Planar Bedding 225.2 N157 27 Primary-structure Planar Bedding 225.6 N146 30 Primary-structure Planar Bedding 225.8 N330 57 Fracture Discontinuous Hairline-fracture GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page C1-150 of 1849 Page 148 of 1847 RCN: CRP-111 0.0