Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-1 Revision 1 APPENDIX 2.3-A Oak Ridge Reservation Selected Bedrock Hydraulic Conductivity Test Results
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-2 Revision 1 Table 2.3-A (Sheet 1 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4) 55-1A A
Nolichucky Shale Conasauga 14.3 19.3 16.8 Slug Hvorslev 4.2E-04 1.2 NA NA 55-1B A
Nolichucky Shale Conasauga 33.8 38.8 36.3 Slug Hvorslev 3.9E-04 1.1 NA NA 55-1C A
Nolichucky Shale Conasauga 70.7 75.7 73.2 Slug Hvorslev 1.2E-04 0.34 NA NA 55-2C A
Nolichucky Shale Conasauga 71 76 73.5 Slug Hvorslev 4.9E-04 1.4 NA NA 55-3A A
Nolichucky Shale Conasauga 9.3 14.3 11.8 Slug Hvorslev 6.0E-04 1.7 NA NA 55-3B A
Nolichucky Shale Conasauga 33.1 38.1 35.6 Slug Hvorslev 1.6E-03 4.6 NA NA 55-3C A
Nolichucky Shale Conasauga 72.5 77.5 75 Slug Hvorslev 6.7E-05 0.19 NA NA 55-4B A
Nolichucky Shale Conasauga 20.5 25.5 23 Slug Hvorslev 4.6E-04 1.3 NA NA 55-4C A
Nolichucky Shale Conasauga 67.6 72.6 70.1 Slug Hvorslev 1.7E-04 0.49 NA NA 56-1A A
Nolichucky Shale Conasauga 14 19 16.5 Slug Hvorslev 4.9E-05 0.14 NA NA 56-1C A
Nolichucky Shale Conasauga 70.3 75.3 72.8 Slug Hvorslev 6.7E-04 1.9 NA NA 56-2A A
Nolichucky Shale Conasauga 10.1 15.1 12.6 Slug Hvorslev 8.1E-04 2.3 NA NA 56-2B A
Nolichucky Shale Conasauga 33.8 38.8 36.3 Slug Hvorslev 3.0E-04 0.84 NA NA 56-2C A
Nolichucky Shale Conasauga 72.3 77.3 74.8 Slug Hvorslev 1.6E-04 0.45 NA NA 56-3A A
Nolichucky Shale Conasauga 12.8 17.8 15.3 Slug Hvorslev 2.8E-04 0.8 NA NA 56-3C A
Nolichucky Shale Conasauga 50.5 55.5 53 Slug Hvorslev 5.6E-04 1.6 NA NA 56-4C A
Nolichucky Shale Conasauga 71.3 76.3 73.8 Slug Hvorslev 1.3E-03 3.6 NA NA 56-5C A
Maynardville Limestone Conasauga 66.6 71.6 69.1 Slug Hvorslev 2.5E-02 70 NA NA GW-1 A
Dismal Gap Formation Conasauga 14.4 25.7 20.1 Bailer-Rec Not Specified 2.6E-05 0.074 NA NA GW-2 A
Dismal Gap Formation Conasauga 47.8 60 53.9 Packer Not Specified 1.1E-05 0.03 NA NA GW-2 A
Dismal Gap Formation Conasauga 38.9 60 49.5 Packer Not Specified 4.9E-06 0.014 NA NA GW-2 A
Dismal Gap Formation Conasauga 39.6 46.7 43.2 Packer Not Specified 9.5E-06 0.027 NA NA GW-2 A
Dismal Gap Formation Conasauga 34.8 41.9 38.4 Packer Not Specified 2.8E-06 0.008 NA NA GW-3 A
Nolichucky Shale Conasauga 23.9 35 29.5 Packer Not Specified 5.1E-05 0.145 NA NA GW-3 A
Nolichucky Shale Conasauga 20.9 32 26.5 Packer Not Specified 4.1E-05 0.115 NA NA GW-3 A
Nolichucky Shale Conasauga 18 23 20.5 Bailer-Rec Not Specified 1.3E-05 0.038 NA NA GW-4 A
Nolichucky Shale Conasauga 17 27.2 22.1 Packer Not Specified 1.1E-03 3.23 NA NA GW-4 A
Nolichucky Shale Conasauga 27.2 50.6 38.9 Packer Not Specified 7.2E-04 2.05 NA NA GW-5 A
Nolichucky Shale Conasauga 3
12.5 7.8 Bailer-Rec Not Specified 2.0E-04 0.575 NA NA GW-6 A
Nolichucky Shale Conasauga 35.7 46.8 41.3 Packer Not Specified 6.7E-05 0.189 NA NA GW-6 A
Nolichucky Shale Conasauga 15.3 31.5 23.4 Bailer-Rec Not Specified 3.1E-05 0.088 NA NA GW-7 A
Nolichucky Shale Conasauga 8.7 16.5 12.6 Bailer-Rec Not Specified 1.9E-04 0.548 NA NA GW-8 A
Nolichucky Shale Conasauga 13 21.9 17.5 Bailer-Rec Not Specified 1.5E-04 0.438 NA NA GW-9 A
Nolichucky Shale Conasauga 51.5 55.3 53.4 Packer Not Specified 6.8E-05 0.192 NA NA GW-9 A
Nolichucky Shale Conasauga 39.6 49.8 44.7 Packer Not Specified 9.0E-05 0.255 NA NA GW-9 A
Nolichucky Shale Conasauga 30.4 40.6 35.5 Packer Not Specified 7.9E-04 2.25 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-3 Revision 1 Table 2.3-A (Sheet 2 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-9 A
Nolichucky Shale Conasauga 20.5 30.7 25.6 Packer Not Specified 2.8E-04 0.795 NA NA GW-10 A
Nolichucky Shale Conasauga 9.6 15 12.3 Bailer-Rec Not Specified 8.0E-05 0.222 NA NA GW-11 A
Nolichucky Shale Conasauga 27.8 39.5 33.7 Packer Not Specified 2.4E-04 0.685 NA NA GW-11 A
Nolichucky Shale Conasauga 19.7 31.4 25.6 Packer Not Specified 4.6E-04 1.29 NA NA GW-11 A
Nolichucky Shale Conasauga 48.7 60.8 54.8 Packer Not Specified 5.0E-05 0.137 NA NA GW-11 A
Nolichucky Shale Conasauga 39 50.8 44.9 Packer Not Specified 4.2E-05 0.118 NA NA GW-12 A
Nolichucky Shale Conasauga 8.7 14.7 11.7 Bailer-Rec Not Specified 3.4E-05 0.096 NA NA GW-13 A
Nolichucky Shale Conasauga 6
14 10 Bailer-Rec Not Specified 3.3E-05 0.093 NA NA GW-13 A
Nolichucky Shale Conasauga 22.5 33.9 28.2 Packer Not Specified 5.8E-04 1.64 NA NA GW-13 A
Nolichucky Shale Conasauga 15.6 27.4 21.5 Packer Not Specified 6.0E-04 1.7 NA NA GW-43 A
Dismal Gap Formation Conasauga 28.6 35 31.8 Bailer-Rec Not Specified 5.0E-05 0.14 NA NA GW-44 A
Dismal Gap Formation Conasauga 27.1 38.7 32.9 Packer Not Specified 1.3E-04 0.381 NA NA GW-44 A
Dismal Gap Formation Conasauga 58 64 61 Packer Not Specified 2.1E-05 0.06 NA NA GW-44 A
Dismal Gap Formation Conasauga 47.5 64 55.8 Packer Not Specified 6.3E-05 0.178 NA NA GW-44 A
Dismal Gap Formation Conasauga 47.6 64 55.8 Packer Not Specified 1.8E-04 0.521 NA NA GW-44 A
Dismal Gap Formation Conasauga 35.3 46.9 41.1 Packer Not Specified 8.7E-05 0.247 NA NA GW-58 A
Maynardville Limestone Conasauga 21.5 33.2 27.4 Packer Not Specified 3.7E-04 1.036 NA NA GW-58 A
Maynardville Limestone Conasauga 30.2 41.9 36.1 Packer Not Specified 2.0E-03 5.81 NA NA GW-59 A
Maynardville Limestone Conasauga 18.2 27 22.6 Packer Not Specified 4.1E-03 11.63 NA NA GW-62 A
Maynardville Limestone Conasauga 22.5 32.5 27.5 Packer Not Specified 3.3E-03 9.3 NA NA GW-62 A
Maynardville Limestone Conasauga 34 44 39 Packer Not Specified 8.9E-05 0.252 NA NA GW-62 A
Maynardville Limestone Conasauga 44 54 49 Packer Not Specified 4.6E-05 0.129 NA NA GW-131 A
Knox Group Knox 120 147 133.5 Packer Homer Semi-Log 4.6E-04 1.3 NA NA GW-131 A
Knox Group Knox 240 267 253.5 Packer Homer Semi-Log 1.3E-03 3.67 NA NA GW-131 A
Knox Group Knox 290 317 303.5 Packer Homer Semi-Log 7.0E-08 0.0002 NA NA GW-131 A
Knox Group Knox 370 397 383.5 Packer Homer Semi-Log 4.4E-05 0.124 NA NA GW-131 A
Knox Group Knox 450 477 463.5 Packer Homer Semi-Log 1.9E-04 0.544 NA NA GW-131 A
Knox Group Knox 490 517 503.5 Packer Homer Semi-Log 1.1E-06 0.003 NA NA GW-131 A
Maynardville Limestone Conasauga 665 692 678.5 Packer Homer Semi-Log 1.0E-05 0.029 NA NA GW-131 A
Maynardville Limestone Conasauga 765 792 778.5 Packer Homer Semi-Log 3.5E-06 0.01 NA NA GW-131 A
Maynardville Limestone Conasauga 892 919 905.5 Packer Homer Semi-Log 7.0E-08 0.0002 NA NA GW-131 A
Maynardville Limestone Conasauga 988 1015 1001.5 Packer Homer Semi-Log 3.3E-04 0.932 NA NA GW-132 A
Friendship Formation Conasauga 145 172 158.5 Packer Homer Semi-Log 1.1E-08 0.00003 NA NA GW-132 A
Pumpkin Valley Shale Conasauga 305 332 318.5 Packer Homer Semi-Log 3.5E-06 0.01 NA NA GW-132 A
Pumpkin Valley Shale Conasauga 347 374 360.5 Packer Homer Semi-Log 3.5E-06 0.01 NA NA GW-132 A
Pumpkin Valley Shale Conasauga 490 517 503.5 Packer Homer Semi-Log 2.1E-06 0.006 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-4 Revision 1 Table 2.3-A (Sheet 3 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-132 A
Pumpkin Valley Shale Conasauga 557 584 570.5 Packer Homer Semi-Log 1.5E-05 0.042 NA NA GW-132 A
Rome Formation Rome 642 669 655.5 Packer Homer Semi-Log 3.9E-04 1.1 NA NA GW-132 A
Rome Formation Rome 690 717 703.5 Packer Homer Semi-Log 3.2E-07 0.0009 NA NA GW-133 A
Dismal Gap Formation Conasauga 105 132 118.5 Packer Homer Semi-Log 1.1E-07 0.0003 NA NA GW-133 A
Dismal Gap Formation Conasauga 148 175 161.5 Packer Homer Semi-Log 1.1E-06 0.003 NA NA GW-133 A
Dismal Gap Formation Conasauga 230 257 243.5 Packer Homer Semi-Log 1.8E-07 0.0005 NA NA GW-133 A
Dismal Gap Formation Conasauga 305 332 318.5 Packer Homer Semi-Log 1.4E-06 0.004 NA NA GW-133 A
Rogersville Shale Conasauga 428 455 441.5 Packer Homer Semi-Log 7.1E-07 0.002 NA NA GW-133 A
Friendship Formation Conasauga 543 570 556.5 Packer Homer Semi-Log 2.1E-07 0.0006 NA NA GW-134 A
Maynardville Limestone Conasauga 75 102 88.5 Packer Homer Semi-Log 2.4E-04 0.67 NA NA GW-134 A
Nolichucky Shale Conasauga 173 200 186.5 Packer Homer Semi-Log 2.8E-06 0.008 NA NA GW-134 A
Nolichucky Shale Conasauga 270 297 283.5 Packer Homer Semi-Log 1.8E-06 0.005 NA NA GW-134 A
Nolichucky Shale Conasauga 360 387 373.5 Packer Homer Semi-Log 3.5E-08 0.0001 NA NA GW-134 A
Nolichucky Shale Conasauga 450 477 463.5 Packer Homer Semi-Log 3.2E-07 0.0009 NA NA GW-134 A
Nolichucky Shale Conasauga 560 587 573.5 Packer Homer Semi-Log 3.5E-07 0.001 NA NA GW-134 A
Dismal Gap Formation Conasauga 730 757 743.5 Packer Homer Semi-Log 7.1E-07 0.002 NA NA GW-134 A
Dismal Gap Formation Conasauga 793 820 806.5 Packer Homer Semi-Log 1.4E-07 0.0004 NA NA GW-135 A
Knox undifferentiated Knox 190 217 203.5 Packer Homer Semi-Log 5.6E-06 0.016 NA NA GW-135 A
Knox undifferentiated Knox 324 351 337.5 Packer Homer Semi-Log 7.2E-05 0.203 NA NA GW-135 A
Knox undifferentiated Knox 397 425 411 Packer Homer Semi-Log 9.6E-05 0.272 NA NA GW-135 A
Knox undifferentiated Knox 446 473 459.5 Packer Homer Semi-Log 7.8E-05 0.222 NA NA GW-135 A
Knox undifferentiated Knox 588 615 601.5 Packer Homer Semi-Log 3.5E-06 0.01 NA NA GW-135 A
Maynardville Limestone Conasauga 710 737 723.5 Packer Homer Semi-Log 1.8E-06 0.005 NA NA GW-135 A
Maynardville Limestone Conasauga 832 859 845.5 Packer Homer Semi-Log 1.8E-05 0.052 NA NA GW-135 A
Maynardville Limestone Conasauga 945 972 958.5 Packer Homer Semi-Log 3.5E-07 0.001 NA NA GW-135 A
Maynardville Limestone Conasauga 990 1017 1003.5 Packer Homer Semi-Log 2.5E-06 0.007 NA NA GW-135 A
Maynardville Limestone Conasauga 1124 1151 1137.5 Packer Homer Semi-Log 1.5E-04 0.411 NA NA GW-135 A
Maynardville Limestone Conasauga 1185 1212 1198.5 Packer Homer Semi-Log 2.5E-06 0.007 NA NA GW-157 A
Knox undifferentiated Knox 145 157 151 Packer Homer Semi-Log 8.5E-05 0.24 NA NA GW-157 A
Knox undifferentiated Knox 215 227 221 Packer Homer Semi-Log 1.8E-04 0.502 NA NA GW-157 A
Knox undifferentiated Knox 265 277 271 Packer Homer Semi-Log 1.1E-03 3.03 NA NA GW-157 A
Knox undifferentiated Knox 282 294 288 Packer Homer Semi-Log 2.0E-04 0.561 NA NA GW-157 A
Knox undifferentiated Knox 314 326 320 Packer Homer Semi-Log 3.2E-06 0.009 NA NA GW-157 A
Knox undifferentiated Knox 326 338 332 Packer Homer Semi-Log 3.1E-04 0.89 NA NA GW-157 A
Knox undifferentiated Knox 344 356 350 Packer Homer Semi-Log 7.1E-08 0.0002 NA NA GW-157 A
Knox undifferentiated Knox 392 404 398 Packer Homer Semi-Log 2.8E-07 0.0008 NA NA GW-157 A
Knox undifferentiated Knox 432 444 438 Packer Homer Semi-Log 7.4E-05 0.209 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-5 Revision 1 Table 2.3-A (Sheet 4 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-157 A
Knox undifferentiated Knox 468 480 474 Packer Homer Semi-Log 1.5E-04 0.417 NA NA GW-456(1)
A Nolichucky Shale Conasauga Not Specified Not Specified Not Specified Pump Theis 9.2E-04 2.6 180 0.0021 GW-457(1)
A Nolichucky Shale Conasauga Not Specified Not Specified Not Specified Pump Theis 1.2E-04 0.34 24 0.00046 GW-458(1)
A Nolichucky Shale Conasauga Not Specified Not Specified Not Specified Pump Theis 1.1E-04 0.31 13 0.00088 GW-459(1)
A Nolichucky Shale Conasauga Not Specified Not Specified Not Specified Pump Theis 2.5E-03 7.1 530 0.0048 GW-460(1)
A Nolichucky Shale Conasauga Not Specified Not Specified Not Specified Pump Theis 3.3E-04 0.96 61 0.0013 GW-461(1)
A Nolichucky Shale Conasauga Not Specified Not Specified Not Specified Pump Theis 9.9E-04 2.8 138 0.0018 GW-462(1)
A Nolichucky Shale Conasauga Not Specified Not Specified Not Specified Pump Theis 5.6E-05 0.16 17 NA GW-427 A
Maynardville Limestone Conasauga 38 48 43 Pump Theis 3.5E-02 99 7690 0.000056 GW-428(1)
A Maynardville Limestone Conasauga Not Specified Not Specified Not Specified Pump Theis 1.6E-02 45 NA NA GW-463 A
Maynardville Limestone Conasauga 45.8 55.8 50.8 Pump Theis 8.1E-03 23 950 0.0004 GW-464(1)
A Maynardville Limestone Conasauga Not Specified Not Specified Not Specified Pump Theis 7.4E-03 21 1037 0.00083 GW-465 A
Maynardville Limestone Conasauga 31 41 36 Pump Theis 2.2E-03 6.2 372 0.0023 GW-466 A
Maynardville Limestone Conasauga 32 42 37 Pump Theis 5.3E-03 15 631 0.00046 GW-467 A
Maynardville Limestone Conasauga 38.5 58.5 48.5 Pump Theis 7.4E-03 21 NA NA 1063 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 12 0.00024 1062/OB-4 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 68 0.0066 1061/OB-5 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 51 0.0041 1060/OB-8 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 38 0.0006 1059/OB-1 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 19 NA 1058/OB-3 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 18 0.00013 1057/OB-7 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 17 0.00019 1056/OB-2 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 18 0.00025 1055/OB-6 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis NA NA 25 0.0007 1002/AP-2 A
Dismal Gap Formation Conasauga 35 45 40 Slug Not Specified 7.3E-04 2.08 NA NA 1003/AP-3 A
Nolichucky Shale Conasauga 27 37 32 Slug Not Specified 9.4E-05 0.266 NA NA 1027/BG-1 A
Dismal Gap Formation Conasauga 20 30 25 Packer Not Specified 1.0E-04 0.296 NA NA 1027/BG-1 A
Dismal Gap Formation Conasauga 30 40 35 Packer Not Specified 6.7E-04 1.9 NA NA 1027/BG-1 A
Dismal Gap Formation Conasauga 40 50 45 Packer Not Specified 1.3E-04 0.381 NA NA 1032/BG-6 A
Maynardville Limestone Conasauga 43 53 48 Slug Not Specified 2.3E-04 0.66 NA NA 1032/BG-6 A
Maynardville Limestone Conasauga 43 53 48 Slug Not Specified 1.8E-04 0.507 NA NA 1035/BG-9 A
Pumpkin Valley Shale Conasauga 20 30 25 Packer Not Specified 2.3E-05 0.066 NA NA 1035/BG-9 A
Pumpkin Valley Shale Conasauga 30 40 35 Packer Not Specified 1.2E-04 0.334 NA NA 1035/BG-9 A
Pumpkin Valley Shale Conasauga 35 45 40 Packer Not Specified 9.8E-05 0.279 NA NA 1035/BG-9 A
Pumpkin Valley Shale Conasauga 35 45 40 Packer Not Specified 1.2E-04 0.331 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-6 Revision 1 Table 2.3-A (Sheet 5 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4) 1035/BG-9 A
Pumpkin Valley Shale Conasauga 40 50 45 Packer Not Specified 1.2E-04 0.331 NA NA 1035/BG-9 A
Pumpkin Valley Shale Conasauga 40 50 45 Packer Not Specified 1.0E-04 0.29 NA NA 1051/OD-4 A
Nolichucky Shale Conasauga 18 28 23 Slug Not Specified 6.0E-04 1.69 NA NA 1051/OD-4 A
Nolichucky Shale Conasauga 18 28 23 Slug Not Specified 3.7E-04 1.06 NA NA 1095/SD-1 A
Knox undifferentiated Knox 108 118 113 Slug Not Specified 3.1E-04 0.874 NA NA 1055/OB-6 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 1.9E-04 0.54 10 0.0009 1056/OB-2 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 1.7E-04 0.48 16.7 0.0072 1057/OB-7 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 9.4E-04 2.66 4.7 0.00041 1058/OB-3 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 4.9E-05 0.14 NA 0.00053 1059/OB-1 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 1.7E-04 0.48 32.2 0.0013 1060/OB-8 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 9.2E-04 2.6 20.7 0.0017 1061/OB-5 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 1.3E-03 3.67 NA 0.0047 1062/OB-4 A
Nolichucky Shale Conasauga 20 70 45 Pump Theis 8.6E-04 2.44 39.4 0.0054 1044/BG18 A
Maynardville Limestone Conasauga 100 160 130 Pump Hantush NA NA 16 NA 1031/BG8 A
Nolichucky Shale Conasauga 37 47 42 Pump Hantush 1.1E-07 0.0003 41 0.0003 1034/BG5 A
Nolichucky Shale Conasauga 35 45 40 Pump Hantush 3.2E-09 0.000009 20 0.000009 GW-104 A
Nolichucky Shale Conasauga 51 74 62.5 Pump Jacob NA NA 37 NA GW-245 A
Nolichucky Shale Conasauga 30 75 52.5 Pump Theis NA NA 13.4 NA GW-246 A
Nolichucky Shale Conasauga 30 75 52.5 Pump Theis NA NA 28 0.001 GW-247 A
Nolichucky Shale Conasauga 30 75 52.5 Pump Theis NA NA 16 0.0004 GW-122 A
Maynardville Limestone Conasauga 92 142 117 Not Specified Not Specified 9.7E-06 0.0274 NA NA GW-120 A
Nolichucky Shale Conasauga 130 180 155 Not Specified Not Specified 1.9E-06 0.0055 NA NA GW-117 A
Nolichucky Shale Conasauga 480 530 505 Not Specified Not Specified 7.1E-08 0.0002 NA NA GW-123 A
Nolichucky Shale Conasauga 525 575 550 Not Specified Not Specified 1.8E-08 0.00005 NA NA GW-473 A
Not Specified Not Specified 30 45 37.5 Pump Chow 7.0E-05 0.1984 NA NA GW-132 A
Friendship Formation Conasauga 850 Not Specified 850 Packer Not Specified 1.02E-06 0.0029 NA NA GW-132 A
Pumpkin Valley Shale Conasauga 720 Not Specified 720 Packer Not Specified 3.75E-06 0.0106 NA NA GW-132 A
Pumpkin Valley Shale Conasauga 650 Not Specified 650 Packer Not Specified 4.04E-06 0.0115 NA NA GW-132 A
Pumpkin Valley Shale Conasauga 520 Not Specified 520 Packer Not Specified 1.99E-06 0.0056 NA NA GW-132 A
Pumpkin Valley Shale Conasauga 450 Not Specified 450 Packer Not Specified 1.47E-05 0.0417 NA NA GW-132 A
Rome Formation Rome 380 Not Specified 380 Packer Not Specified 4.08E-04 1.1565 NA NA GW-132 A
Rome Formation Rome 320 Not Specified 320 Packer Not Specified 3.05E-07 0.0009 NA NA GW-133 A
Dismal Gap Formation Conasauga 920 Not Specified 920 Packer Not Specified 1.0E-07 0.0003 NA NA GW-133 A
Dismal Gap Formation Conasauga 850 Not Specified 850 Packer Not Specified 1.07E-06 0.003 NA NA GW-133 A
Dismal Gap Formation Conasauga 760 Not Specified 760 Packer Not Specified 1.7E-07 0.0005 NA NA GW-133 A
Dismal Gap Formation Conasauga 680 Not Specified 680 Packer Not Specified 1.49E-06 0.0042 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-7 Revision 1 Table 2.3-A (Sheet 6 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-133 A
Rogersville Shale Conasauga 550 Not Specified 550 Packer Not Specified 6.42E-07 0.0018 NA NA GW-133 A
Friendship Formation Conasauga 450 Not Specified 450 Packer Not Specified 1.98E-07 0.0006 NA NA GW-134 A
Maynardville Limestone Conasauga 920 Not Specified 920 Packer Not Specified 2.37E-04 0.6718 NA NA GW-134 A
Maynardville Limestone Conasauga 800 Not Specified 800 Packer Not Specified 2.87E-06 0.0081 NA NA GW-134 A
Nolichucky Shale Conasauga 650 Not Specified 650 Packer Not Specified 1.74E-06 0.0049 NA NA GW-134 A
Nolichucky Shale Conasauga 560 Not Specified 560 Packer Not Specified 5.14E-06 0.0145 NA NA GW-134 A
Nolichucky Shale Conasauga 500 Not Specified 500 Packer Not Specified 3.17E-07 0.0009 NA NA GW-134 A
Nolichucky Shale Conasauga 400 Not Specified 400 Packer Not Specified 4.26E-07 0.0012 NA NA GW-134 A
Dismal Gap Formation Conasauga 240 Not Specified 240 Packer Not Specified 5.55E-07 0.0016 NA NA GW-134 A
Dismal Gap Formation Conasauga 200 Not Specified 200 Packer Not Specified 1.33E-07 0.0004 NA NA GW-135 A
Knox undifferentiated Knox 950 Not Specified 950 Packer Not Specified 5.49E-06 0.0156 NA NA GW-135 A
Knox undifferentiated Knox 820 Not Specified 820 Packer Not Specified 7.15E-05 0.2027 NA NA GW-135 A
Knox undifferentiated Knox 750 Not Specified 750 Packer Not Specified 9.61E-05 0.2724 NA NA GW-135 A
Knox undifferentiated Knox 700 Not Specified 700 Packer Not Specified 7.84E-05 0.2222 NA NA GW-135 A
Knox undifferentiated Knox 550 Not Specified 550 Packer Not Specified 3.55E-06 0.0101 NA NA GW-135 A
Maynardville Limestone Conasauga 400 Not Specified 400 Packer Not Specified 1.69E-04 0.0048 NA NA GW-135 A
Maynardville Limestone Conasauga 300 Not Specified 300 Packer Not Specified 1.83E-05 0.0519 NA NA GW-135 A
Maynardville Limestone Conasauga 150 Not Specified 150 Packer Not Specified 4.30E-07 0.0012 NA NA GW-135 A
Maynardville Limestone Conasauga 100 Not Specified 100 Packer Not Specified 2.30E-06 0.0065 NA NA GW-135 A
Maynardville Limestone Conasauga 50 Not Specified 50 Packer Not Specified 1.45E-04 0.411 NA NA GW-135 A
Maynardville Limestone Conasauga 100 Not Specified 100 Packer Not Specified 2.55E-06 0.0072 NA NA 458 B
Not Specified Conasauga 150 203 176.5 Slug Not Specified 1.06E-05 0.03 1.6 1.50E-08 458 B
Not Specified Conasauga 190 203 196.5 Slug Not Specified 1.06E-05 0.03 0.3 1.60E-12 458 B
Not Specified Conasauga 150 203 176.5 Pump Not Specified 1.06E-05 0.03 1.6 1.60E-05 459 B
Not Specified Conasauga 100 150 125 Slug Not Specified 7.06E-08 0.0002 0.011 1.60E-04 459 B
Not Specified Conasauga 136 150 143 Slug Not Specified 2.86E-05 0.081 1.1 1.60E-05 460 B
Not Specified Conasauga 44 100 72 Slug Not Specified 7.06E-06 0.020 1.4 1.60E-04 460 B
Not Specified Conasauga 84 100 92 Slug Not Specified 5.29E-06 0.015 0.2 1.40E-04 460 B
Not Specified Conasauga 44 100 72 Pump Not Specified 1.06E-05 0.03 1.6 7.50E-04 439 B
Not Specified Conasauga 24 34 29 Slug Not Specified 2.05E-04 0.58 NA NA 440 B
Not Specified Conasauga 26 36 31 Slug Not Specified 1.87E-05 0.053 NA NA 472 B
Not Specified Conasauga 15 20 17.5 Slug Not Specified 1.16E-04 0.33 NA NA 464 B
Not Specified Conasauga 6
11 8.5 Slug Not Specified 2.68E-04 0.76 NA NA 468 B
Not Specified Conasauga 10 15 12.5 Slug Not Specified 1.73E-04 0.49 NA NA OMW-01A C
Not Specified Conasauga(6) 210 258 234 Slug Bouwer-Rice 1.05E-05 0.03 NA NA OMW-01AA C
Not Specified Conasauga(6) 120 170 145 Slug Bouwer-Rice 8.91E-06 0.025 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-8 Revision 1 Table 2.3-A (Sheet 7 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
OMW-02A C
Not Specified Conasauga(6) 200 250 225 Slug Bouwer-Rice 1.20E-05 0.034 NA NA OMW-02AA C
Not Specified Conasauga(6) 120 170 145 Slug Bouwer-Rice 1.49E-05 0.042 NA NA OMW-02B C
Not Specified Conasauga(6) 300 350 325 Slug Bouwer-Rice 9.84E-06 0.028 NA NA OMW-03A C
Not Specified Conasauga(6) 60 120 90 Slug Bouwer-Rice 2.46E-04 0.697 NA NA OMW-03B(2)
C Not Specified Conasauga(6) 152.7 177.7 165.2 Slug Bouwer-Rice 4.12E-05 0.117 NA NA OMW-04A(2)
C Not Specified Conasauga(6) 30 90 60 Slug Bouwer-Rice 5.81E-04 1.646 NA NA OMW-04B C
Not Specified Conasauga(6) 119 164 141.5 Slug Bouwer-Rice 4.40E-06 0.012 NA NA OMW-04C C
Not Specified Conasauga(6) 182.7 217.7 200.2 Slug Bouwer-Rice 1.58E-04 0.448 NA NA 7-1(3)
D Not Specified Conasauga 60 120 90 Slug Hvorslev 3.86E-06 0.011 NA NA 7-2(3)
D Not Specified Conasauga 35 95 65 Slug Hvorslev 5.10E-05 0.145 NA NA 7-3 D
Not Specified Conasauga 68 88 78 Slug Hvorslev 2.98E-04 0.845 NA NA 7-4 D
Not Specified Conasauga 70 90 80 Slug Hvorslev 1.05E-05 0.030 NA NA 7-5 D
Not Specified Conasauga 76 95 85.5 Slug Hvorslev 3.84E-05 0.109 NA NA 7-7 D
Not Specified Conasauga 18 28 23 Slug Hvorslev 1.12E-04 0.317 NA NA 7-8 D
Not Specified Conasauga 20 30 25 Slug Hvorslev 2.29E-05 0.065 NA NA 7-9 D
Not Specified Conasauga 20 30 25 Slug Hvorslev 6.59E-05 0.187 NA NA 7-11(3)
D Not Specified Conasauga 38 86 62 Slug Hvorslev 1.42E-05 0.040 NA NA 7-12 D
Not Specified Conasauga 60 70 65 Slug Hvorslev 1.13E-06 0.003 NA NA 7-13(3)
D Not Specified Conasauga 10 28 19 Slug Hvorslev 1.47E-04 0.417 NA NA 7-14 D
Not Specified Conasauga 60 70 65 Slug Hvorslev 8.21E-06 0.023 NA NA ETF-1 E
Dismal Gap Formation Conasauga 24.8 28.7 26.7 Slug/Pump Hvorslev 3.10E-04 0.879 24.6 5.12E-04 ETF-2 E
Dismal Gap Formation Conasauga 27.9 31.8 29.8 Slug Hvorslev 2.30E-05 0.065 NA NA ETF-3 E
Dismal Gap Formation Conasauga 26.9 30.8 28.9 Slug/Pump Hvorslev 5.00E-05 0.142 67.6 0.01 ETF-4 E
Dismal Gap Formation Conasauga 26.8 30.8 28.8 Slug Hvorslev 1.30E-04 0.369 NA NA ETF-5 E
Dismal Gap Formation Conasauga 26.3 30.2 28.3 Slug Hvorslev 3.00E-04 0.850 NA NA ETF-6 E
Dismal Gap Formation Conasauga 26.2 30.1 28.1 Slug Hvorslev 3.90E-04 1.106 NA NA ETF-7 E
Dismal Gap Formation Conasauga 26.5 30.4 28.4 Slug Hvorslev 2.00E-04 0.567 NA NA ETF-8 E
Dismal Gap Formation Conasauga 25.8 29.8 27.8 Slug/Pump Hvorslev 3.10E-04 0.879 58 0.03 ETF-9 E
Dismal Gap Formation Conasauga 27 30.9 28.9 Slug/Pump Hvorslev 5.10E-05 0.145 19.4 0.01 ETF-10 E
Dismal Gap Formation Conasauga 27.1 31.1 29.1 Pump Theis NA NA 27 3.34E-04 ETF-11 E
Dismal Gap Formation Conasauga 41.7 49.6 45.6 Slug Hvorslev 2.40E-04 0.680 NA NA ETF-12 E
Dismal Gap Formation Conasauga 42.2 50.1 46.2 Slug Hvorslev 4.10E-04 1.162 NA NA ETF-13 E
Dismal Gap Formation Conasauga 240.9 250.7 245.8 Slug Hvorslev 1.70E-05 0.048 NA NA ETF-14 E
Dismal Gap Formation Conasauga 84.7 94.6 89.7 Slug Hvorslev 2.30E-05 0.065 NA NA ETF-15 E
Dismal Gap Formation Conasauga 36.9 46.8 41.8 Slug Hvorslev 6.60E-06 0.019 NA NA ETF-16 E
Dismal Gap Formation Conasauga 234.6 244.5 239.6 Slug Hvorslev 2.90E-05 0.082 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-9 Revision 1 Table 2.3-A (Sheet 8 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
ETF-17 E
Dismal Gap Formation Conasauga 12.8 18.7 15.8 Slug Hvorslev 9.60E-06 0.027 NA NA ETF-20 E
Dismal Gap Formation Conasauga 15.9 21.8 18.9 Slug Hvorslev 2.30E-04 0.652 NA NA ETF-21 E
Dismal Gap Formation Conasauga 14.5 20.4 17.5 Slug Hvorslev 1.10E-05 0.031 NA NA ETF-22 E
Dismal Gap Formation Conasauga 16.6 22.5 19.6 Slug Hvorslev 4.50E-05 0.128 NA NA ETF-23 E
Dismal Gap Formation Conasauga 14.4 20.3 17.4 Slug Hvorslev 6.00E-05 0.170 NA NA ETF-24 E
Dismal Gap Formation Conasauga 15.7 21.7 18.7 Slug Hvorslev 6.00E-04 1.701 NA NA ETF-25 E
Dismal Gap Formation Conasauga 15.7 21.6 18.6 Slug Hvorslev 7.60E-05 0.215 NA NA ETF-26 E
Dismal Gap Formation Conasauga 15.3 21.2 18.2 Slug Hvorslev 4.70E-05 0.133 NA NA ETF-27 E
Dismal Gap Formation Conasauga 14.5 20.4 17.5 Slug Hvorslev 2.20E-05 0.062 NA NA ETF-28 E
Dismal Gap Formation Conasauga 14.4 20.3 17.4 Slug Hvorslev 9.20E-06 0.026 NA NA ETF-29 E
Dismal Gap Formation Conasauga 14.8 20.7 17.8 Slug Hvorslev 2.20E-05 0.062 NA NA ETF-31 E
Dismal Gap Formation Conasauga 11.4 17.3 14.3 Slug Hvorslev 2.40E-05 0.068 NA NA ETF-32 E
Dismal Gap Formation Conasauga 13.9 19.8 16.9 Slug Hvorslev 2.90E-05 0.082 NA NA ETF-33 E
Dismal Gap Formation Conasauga 14.1 20 17.1 Slug Hvorslev 2.38E-03 6.746 NA NA ETF-34 E
Dismal Gap Formation Conasauga 16 21.9 19.0 Slug Hvorslev 2.10E-05 0.060 NA NA ETF-35 E
Dismal Gap Formation Conasauga 14.7 20.6 17.7 Slug Hvorslev 1.50E-05 0.043 NA NA ETF-36 E
Dismal Gap Formation Conasauga 15.3 21.2 18.2 Slug Hvorslev 3.00E-05 0.085 NA NA ETF-37 E
Dismal Gap Formation Conasauga 15.5 21.4 18.5 Slug Hvorslev 7.90E-05 0.224 NA NA ETF-38 E
Dismal Gap Formation Conasauga 16.1 22 19.1 Slug Hvorslev 9.70E-05 0.275 NA NA ETF-39 E
Dismal Gap Formation Conasauga 16.3 22.2 19.2 Slug Hvorslev 4.30E-05 0.122 NA NA ETF-40 E
Dismal Gap Formation Conasauga 14.8 20.7 17.7 Slug Hvorslev 5.60E-05 0.159 NA NA 668 F
Not Specified Conasauga 11 13 12.0 Injection Not Specified 5.21E-05 0.148 0.301 NA 668 F
Not Specified Conasauga 13 15 14.0 Injection Not Specified 1.40E-06 0.004 0.080 NA 669 F
Not Specified Conasauga 7.5 8.5 8.0 Injection Not Specified 9.84E-05 0.279 0.28 NA 739 F
Not Specified Conasauga 25 27.5 26.3 Injection Not Specified 4.75E-04 1.345 3.34 NA 741 F
Not Specified Conasauga 15 21 18.0 Injection Not Specified 2.31E-04 0.656 3.98 NA 747 F
Not Specified Conasauga 16 24 20.0 Injection Not Specified 3.82E-05 0.108 0.872 NA 748 F
Not Specified Conasauga 14.5 23.5 19.0 Injection Not Specified 5.09E-05 0.144 1.292 NA 749 F
Not Specified Conasauga 14 16 15.0 Injection Not Specified 1.97E-05 0.056 0.118 NA 749 F
Not Specified Conasauga 18 21 19.5 Injection Not Specified 7.64E-05 0.217 0.646 NA 756 F
Not Specified Conasauga 18 20.5 19.3 Injection Not Specified 2.55E-03 7.218 18.3 NA 757 F
Not Specified Conasauga 12 16 14.0 Injection Not Specified 2.78E-05 0.079 0.312 NA 757 F
Not Specified Conasauga 16 22 19.0 Injection Not Specified 6.94E-05 0.197 1.184 NA 758 F
Not Specified Conasauga 14 23 18.5 Injection Not Specified 9.72E-06 0.028 0.248 NA 759 F
Not Specified Conasauga 14 15.5 14.8 Injection Not Specified 4.05E-04 1.148 1.722 NA 759 F
Not Specified Conasauga 20 23 21.5 Injection Not Specified 1.74E-04 0.492 1.507 NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-10 Revision 1 Table 2.3-A (Sheet 9 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4) 760 F
Not Specified Conasauga 14 23 18.5 Injection Not Specified 6.37E-05 0.180 1.615 NA 766 F
Not Specified Conasauga 10 13.5 11.8 Injection Not Specified 2.20E-04 0.623 2.153 NA 767 F
Not Specified Conasauga 38 40 39.0 Injection Not Specified 5.09E-05 0.144 0.291 NA 768 F
Not Specified Conasauga 7
15 11.0 Injection Not Specified 1.09E-05 0.031 0.248 NA 774 F
Not Specified Conasauga 8
10 9.0 Injection Not Specified 6.83E-03 19.357 38.75 NA 775 F
Not Specified Conasauga 39 40 39.5 Injection Not Specified 2.89E-04 0.820 0.818 NA 775 F
Not Specified Conasauga 40 42 41.0 Injection Not Specified 8.45E-05 0.240 0.474 NA 777 F
Not Specified Conasauga 37 38 37.5 Injection Not Specified 3.59E-05 0.102 0.103 NA 779 F
Not Specified Conasauga 39 41 40.0 Injection Not Specified 3.36E-04 0.951 1.938 NA 779 F
Not Specified Conasauga 41 43 42.0 Injection Not Specified 7.99E-05 0.226 0.452 NA 781 F
Not Specified Conasauga 29 33 31.0 Injection Not Specified 3.70E-05 0.105 0.431 NA 781 F
Not Specified Conasauga 33 35 34.0 Injection Not Specified 2.66E-04 0.755 1.507 NA 782 F
Not Specified Conasauga 12 14 13 Injection Not Specified 5.90E-04 1.673 3.552 NA 783 F
Not Specified Conasauga 28 29 28.5 Injection Not Specified 4.51E-04 1.28 1.292 NA 904 F
Not Specified Conasauga 41 44 42.5 Injection Not Specified 1.62E-03 4.593 13.993 NA 905 F
Not Specified Conasauga 36 37.5 36.8 Injection Not Specified 2.78E-04 0.787 1.184 NA 1118 F
Not Specified Conasauga 8
12 10 Injection Not Specified 6.60E-05 0.187 0.743 NA 1119 F
Not Specified Conasauga 24.5 27 25.8 Injection Not Specified 2.55E-04 0.722 1.830 NA 1119 F
Not Specified Conasauga 30.5 33 31.8 Injection Not Specified 1.74E-04 0.492 1.184 NA 1121 F
Not Specified Conasauga 8.5 9.5 9
Injection Not Specified 7.18E-04 2.034 2.045 NA 1121 F
Not Specified Conasauga 9.5 11.5 10.5 Injection Not Specified 2.20E-04 0.623 1.184 NA 1122 F
Not Specified Conasauga 38 41 39.5 Injection Not Specified 3.36E-05 0.095 0.280 NA 1122 F
Not Specified Conasauga 41 42.5 41.8 Injection Not Specified 2.08E-04 0.591 0.883 NA 1122 F
Not Specified Conasauga 44 46 45 Injection Not Specified 4.17E-05 0.118 0.237 NA 1126 F
Not Specified Conasauga 48 49.5 48.8 Injection Not Specified 8.91E-04 2.526 3.767 NA 1126 F
Not Specified Conasauga 56 57 56.5 Injection Not Specified 3.36E-04 0.951 0.947 NA 1127 F
Not Specified Conasauga 17.5 19 18.3 Injection Not Specified 3.24E-04 0.919 1.399 NA 1127 F
Not Specified Conasauga 20.2 21 20.6 Injection Not Specified 5.21E-04 1.476 1.184 NA 1128 F
Not Specified Conasauga 46 52 49.0 Injection Not Specified 6.13E-05 0.174 1.055 NA 1128 F
Not Specified Conasauga 56 57 56.5 Injection Not Specified 4.63E-05 0.131 0.129 NA 1129 F
Not Specified Conasauga 32 33 32.5 Injection Not Specified 6.25E-05 0.177 0.172 NA 1129 F
Not Specified Conasauga 35.5 36.5 36 Injection Not Specified 2.20E-04 0.623 0.614 NA GW-404(2)
G Dismal Gap Formation Conasauga 26.5 38.5 32.5 Packer Multiple 1.90E-05 0.054 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 38 50 44 Packer Multiple 9.40E-06 0.027 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 50 62 56 Packer Multiple 9.36E-06 0.027 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 62 74 68 Packer Multiple 7.00E-06 0.020 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-11 Revision 1 Table 2.3-A (Sheet 10 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-404(2)
G Dismal Gap Formation Conasauga 74 86 80 Packer Multiple 4.30E-05 0.122 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 86 98 92 Packer Multiple 5.42E-06 0.015 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 98 110 104 Packer Multiple 6.57E-05 0.186 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 110 122 116 Packer Multiple 1.72E-04 0.488 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 122 134 128 Packer Multiple 2.90E-05 0.082 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 134 146 140 Packer Multiple 5.86E-05 0.166 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 146 158 152 Packer Multiple 5.44E-06 0.015 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 158 170 164 Packer Multiple 4.07E-05 0.115 NA NA GW-404(2)
G Dismal Gap Formation Conasauga 170 182 176 Packer Multiple 2.77E-06 0.008 NA NA GW-455(2)
G Nolichucky Shale Conasauga 65 87 76 Packer Multiple 6.47E-05 0.183 NA NA GW-455(2)
G Nolichucky Shale Conasauga 87 109 98 Packer Multiple 1.60E-05 0.045 NA NA GW-455(2)
G Dismal Gap Formation/
Nolichucky Shale Conasauga 109 131 120 Packer Multiple 4.64E-07 0.001 NA NA GW-455(2)
G Dismal Gap Formation Conasauga 138 160 149 Packer Multiple 2.61E-05 0.074 NA NA GW-455(2)
G Dismal Gap Formation Conasauga 152.8 174.8 163.8 Packer Multiple 6.41E-05 0.182 NA NA GW-471(2)
G Dismal Gap Formation Conasauga 33 45 39 Packer Multiple 3.09E-04 0.876 NA NA GW-471(2)
G Dismal Gap Formation Conasauga 45 57 51 Packer Multiple 2.29E-04 0.649 NA NA GW-471(2)
G Dismal Gap Formation Conasauga 57 69 63 Packer Multiple 4.61E-05 0.131 NA NA GW-471(2)
G Dismal Gap Formation Conasauga 69 81 75 Packer Multiple 5.80E-06 0.016 NA NA GW-471(2)
G Dismal Gap Formation Conasauga 81 93 87 Packer Multiple 5.39E-06 0.015 NA NA GW-471(2)
G Dismal Gap Formation Conasauga 84.4 96.4 90.4 Packer Multiple 7.10E-05 0.201 NA NA GW-403 G
Dismal Gap Formation Conasauga 306 328 317 Packer Multiple 4.90E-08 0.0001 NA NA GW-403 G
Dismal Gap Formation Conasauga 387 409 398 Packer Multiple 1.37E-07 0.0004 NA NA GW-455 G
Dismal Gap Formation Conasauga 157.7 185.8 171.8 Slug Hvorslev 4.57E-05 0.130 NA NA GW-471 G
Dismal Gap Formation Conasauga 89.7 103.4 96.6 Slug Hvorslev 1.18E-06 0.003 NA NA GW-473 G
Dismal Gap Formation Conasauga 68.4 94.4 81.4 Slug Hvorslev 3.93E-05 0.111 NA NA GW-474 G
Dismal Gap Formation Conasauga 27.9 45.1 36.5 Slug Hvorslev 3.33E-05 0.094 NA NA GW-475A G
Dismal Gap Formation Conasauga 86.4 99.7 93.1 Slug Hvorslev 7.85E-07 0.002 NA NA GW-475B G
Dismal Gap Formation Conasauga 49.9 62.9 56.4 Slug Hvorslev 6.96E-05 0.197 NA NA GW-476A G
Dismal Gap Formation Conasauga 69.9 83 76.5 Slug Hvorslev 6.61E-06 0.019 NA NA GW-476B G
Dismal Gap Formation Conasauga 36.9 49.4 43.2 Slug Hvorslev 7.96E-05 0.226 NA NA GW-477A G
Dismal Gap Formation Conasauga 54.7 68.7 61.7 Slug Hvorslev 1.37E-05 0.039 NA NA GW-477B G
Maynardville Limestone Conasauga 22.3 34.9 28.6 Slug Hvorslev 1.12E-05 0.032 NA NA GW-478A G
Dismal Gap Formation Conasauga 66.9 81.3 74.1 Slug Hvorslev 9.81E-06 0.028 NA NA GW-478B G
Dismal Gap Formation Conasauga 35.2 47.2 41.2 Slug Hvorslev 2.35E-05 0.067 NA NA GW-480A G
Dismal Gap Formation Conasauga 33.6 37.6 35.6 Slug Hvorslev 2.86E-06 0.008 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-12 Revision 1 Table 2.3-A (Sheet 11 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-480B G
Maynardville Limestone Conasauga 28.6 32.6 30.6 Slug Hvorslev 5.23E-06 0.015 NA NA GW-481A G
Dismal Gap Formation Conasauga 31.4 35.1 33.3 Slug Hvorslev 1.81E-04 0.513 NA NA GW-481B G
Maynardville Limestone Conasauga 28.6 32.6 30.6 Slug Hvorslev 6.76E-06 0.019 NA NA GW-482A G
Dismal Gap Formation Conasauga 32.7 36.7 34.7 Slug Hvorslev 1.82E-06 0.005 NA NA GW-482B G
Maynardville Limestone Conasauga 26.2 30.2 28.2 Slug Hvorslev 2.29E-05 0.065 NA NA GW-483 G
Maynardville Limestone Conasauga 18.4 28 23.2 Slug Hvorslev 3.27E-05 0.093 NA NA GW-474 G
Dismal Gap Formation Conasauga 27.9 45.1 36.5 Pump Multiple 2.66E-05 0.075 2.26 NA GW-475B G
Dismal Gap Formation Conasauga 49.9 62.9 56.4 Pump Multiple 2.88E-05 0.082 2.45 1.35E-04 GW-476B G
Dismal Gap Formation Conasauga 36.9 49.4 43.2 Pump Multiple 6.47E-05 0.183 5.50 2.38E-04 GW-477B G
Maynardville Limestone Conasauga 22.3 34.9 28.6 Pump Multiple 7.48E-05 0.212 6.36 7.92E-04 GW-478B G
Dismal Gap Formation Conasauga 35.2 47.2 41.2 Pump Multiple 3.54E-05 0.100 3.01 1.64E-04 GW-471 G
Dismal Gap Formation Conasauga 89.7 105.6 97.7 Pump Multiple 1.28E-05 0.036 0.72 1.47E-04 GW-473 G
Dismal Gap Formation Conasauga 68.4 94.4 81.4 Pump Multiple 1.01E-05 0.029 0.57 NA GW-475A G
Dismal Gap Formation Conasauga 86.4 99.7 93.1 Pump Multiple 1.23E-05 0.035 0.70 1.65E-03 GW-476A G
Dismal Gap Formation Conasauga 69.9 83 76.5 Pump Multiple 1.14E-05 0.032 0.65 3.60E-05 GW-477A G
Dismal Gap Formation Conasauga 54.7 68.7 61.7 Pump Multiple 1.63E-05 0.046 0.92 1.51E-04 GW-478A G
Dismal Gap Formation Conasauga 67.9 81.3 74.6 Pump Multiple 1.00E-05 0.028 0.57 1.62E-04 GW-136 H
Nolichucky Shale Conasauga 53 80 66.5 Packer Log-Log 6.10E-06 0.173 NA NA GW-136 H
Nolichucky Shale Conasauga 113 140 126.5 Packer Log-Log 4.40E-06 0.012 NA NA GW-136 H
Nolichucky Shale Conasauga 175 202 188.5 Packer Log-Log 4.50E-06 0.013 NA NA GW-136 H
Nolichucky Shale Conasauga 216 243 229.5 Packer Log-Log 1.50E-06 0.004 NA NA GW-136 H
Nolichucky Shale Conasauga 221 248 234.5 Packer Log-Log 2.80E-07 0.001 NA NA GW-136 H
Nolichucky Shale Conasauga 283 310 296.5 Packer Log-Log 2.40E-05 0.068 NA NA GW-136 H
Nolichucky Shale Conasauga 288 315 301.5 Packer Log-Log 3.90E-05 0.111 NA NA GW-136 H
Nolichucky Shale Conasauga 420 447 433.5 Packer Log-Log 1.00E-05 0.028 NA NA GW-136 H
Nolichucky Shale Conasauga 501 528 514.5 Packer Log-Log 4.20E-07 0.001 NA NA GW-137 H
Nolichucky Shale Conasauga 337 364 350.5 Packer Log-Log 1.40E-04 0.397 NA NA GW-137 H
Nolichucky Shale Conasauga 675 702 688.5 Packer Log-Log 1.30E-07 0.0004 NA NA GW-139 H
Nolichucky Shale Conasauga 195 217 206.0 Packer Log-Log 5.90E-06 0.017 NA NA GW-139 H
Nolichucky Shale Conasauga 300 322 311.0 Packer Log-Log 1.70E-06 0.005 NA NA GW-139 H
Nolichucky Shale Conasauga 382 404 393.0 Packer Log-Log 2.70E-07 0.001 NA NA GW-401 H
Nolichucky Shale Conasauga 125 147 136.0 Packer Log-Log 8.20E-06 0.023 NA NA GW-401 H
Nolichucky Shale Conasauga 244 266 255.0 Packer Log-Log 1.50E-06 0.004 NA NA GW-401 H
Nolichucky Shale Conasauga 266 288 277.0 Packer Log-Log 6.50E-06 0.018 NA NA GW-401 H
Nolichucky Shale Conasauga 317 339 328.0 Packer Log-Log 7.80E-07 0.002 NA NA GW-401 H
Nolichucky Shale Conasauga 386 408 397.0 Packer Log-Log 1.00E-05 0.028 NA NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-13 Revision 1 Table 2.3-A (Sheet 12 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-401 H
Nolichucky Shale Conasauga 266 273 269.5 Packer Log-Log 9.50E-06 0.027 NA NA GW-401 H
Nolichucky Shale Conasauga 273 280 276.5 Packer Log-Log 5.30E-05 0.150 NA NA GW-401 H
Nolichucky Shale Conasauga 280 287 283.5 Packer Log-Log 3.00E-05 0.085 NA NA GW-401 H
Nolichucky Shale Conasauga 386 393 389.5 Packer Log-Log 1.60E-05 0.045 NA NA GW-401 H
Nolichucky Shale Conasauga 393 400 396.5 Packer Log-Log 2.70E-05 0.077 NA NA GW-401 H
Nolichucky Shale Conasauga 400 407 403.5 Packer Log-Log 4.80E-07 0.001 NA NA GW-401 H
Nolichucky Shale Conasauga 448 455 451.5 Packer Log-Log 3.80E-05 0.108 NA NA GW-402 H
Nolichucky Shale Conasauga 110 137 123.5 Packer Log-Log 1.30E-05 0.037 NA NA GW-402 H
Nolichucky Shale Conasauga 150 177 163.5 Packer Log-Log 2.50E-05 0.071 NA NA GW-402 H
Nolichucky Shale Conasauga 192 219 205.5 Packer Log-Log 1.20E-06 0.003 NA NA GW-402 H
Nolichucky Shale Conasauga 243 270 256.5 Packer Log-Log 2.40E-06 0.007 NA NA GW-402 H
Nolichucky Shale Conasauga 270 297 283.5 Packer Log-Log 2.90E-07 0.001 NA NA GW-402 H
Nolichucky Shale Conasauga 302 329 315.5 Packer Log-Log 4.60E-08 0.0001 NA NA GW-402 H
Nolichucky Shale Conasauga 333 360 346.5 Packer Log-Log 5.50E-08 0.0002 NA NA GW-402 H
Nolichucky Shale Conasauga 373 400 386.5 Packer Log-Log 1.20E-07 0.0003 NA NA GW-402 H
Nolichucky Shale Conasauga 403 430 416.5 Packer Log-Log 2.70E-07 0.001 NA NA GW-402 H
Nolichucky Shale Conasauga 525 552 538.5 Packer Log-Log 2.00E-07 0.001 NA NA GW-402 H
Nolichucky Shale Conasauga 559 586 572.5 Packer Log-Log 4.40E-08 0.0001 NA NA GW-403 H
Nolichucky Shale Conasauga 92 114 103 Packer Log-Log 1.60E-03 4.535 NA NA GW-403 H
Nolichucky Shale Conasauga 160 182 171 Packer Log-Log 7.80E-06 0.022 NA NA GW-403 H
Nolichucky Shale Conasauga 234 256 245 Packer Log-Log 9.10E-05 0.258 NA NA GW-403 H
Nolichucky Shale Conasauga 275 297 286 Packer Log-Log 3.50E-05 0.099 NA NA GW-403 H
Nolichucky Shale Conasauga 306 328 317 Packer Log-Log 4.90E-08 0.0001 NA NA GW-468 H
Nolichucky Shale Conasauga 109 131 120 Packer Log-Log 1.70E-05 0.048 NA NA GW-468 H
Nolichucky Shale Conasauga 138 160 149 Packer Log-Log 9.00E-05 0.255 NA NA GW-468 H
Nolichucky Shale Conasauga 210 232 221 Packer Log-Log 3.40E-06 0.010 NA NA GW-468 H
Nolichucky Shale Conasauga 279 301 290 Packer Log-Log 1.40E-06 0.004 NA NA GW-468 H
Nolichucky Shale Conasauga 355 377 366 Packer Log-Log 1.80E-05 0.051 NA NA GW-468 H
Nolichucky Shale Conasauga 413 435 424 Packer Log-Log 9.40E-09 0.00003 NA NA GW-468 H
Nolichucky Shale Conasauga 465 487 476 Packer Log-Log 1.00E-07 0.0003 NA NA GW-468 H
Nolichucky Shale Conasauga 109 116 112.5 Packer Log-Log 4.40E-05 0.125 NA NA GW-134 H
Nolichucky Shale Conasauga 173 200 186.5 Packer Not Specified 2.87E-06 0.0081 NA NA GW-134 H
Nolichucky Shale Conasauga 270 297 283.5 Packer Not Specified 1.74E-06 0.0049 NA NA GW-134 H
Nolichucky Shale Conasauga 360 387 373.5 Packer Not Specified 5.14E-08 0.0001 NA NA GW-134 H
Nolichucky Shale Conasauga 450 477 463.5 Packer Not Specified 3.17E-07 0.0009 NA NA GW-134 H
Nolichucky Shale Conasauga 560 587 573.5 Packer Not Specified 4.26E-07 0.0012 NA NA GW-381 I
Maynardville Limestone Conasauga 46.3 60.4 53.4 Pump Theis 3.33E-03 9.45 2834.78 2.78E-03
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-14 Revision 1 Table 2.3-A (Sheet 13 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
GW-153 I
Maynardville Limestone Conasauga 49.5 59.5 54.5 Pump Theis 1.08E-02 30.52 9156.35 6.00E-03 GW-223 I
Maynardville Limestone Conasauga 80 90 85.0 Pump Theis 1.51E-03 4.28 1284.16 1.62E-03 GW-151 I
Maynardville Limestone Conasauga 86 96 91.0 Pump Theis 7.94E-04 2.25 674.68 4.72E-04 GW-750 I
Maynardville Limestone Conasauga 61.2 72.7 67.0 Pump Theis 6.53E-04 1.85 555.62 1.93E-03 GW-735 I
Maynardville Limestone Conasauga 67.9 78.1 73.0 Pump Theis 5.86E-04 1.66 498.92 1.50E-03 GW-734 I
Maynardville Limestone Conasauga 59.4 Not Specified 59.4 Pump Theis 1.20E-03 3.40 1020.52 1.40E-03 GW-168 I
Maynardville Limestone Conasauga 104 135.4 119.7 Pump Theis 2.65E-04 0.75 223.95 9.50E-05 GW-733 I
Maynardville Limestone Conasauga 240.1 256.5 248.3 Pump Theis 1.48E-04 0.42 125.30 3.80E-04 GW-722 I
Maynardville Limestone Conasauga 333 333 333.0 Pump Theis 9.17E-05 0.26 78.52 1.69E-05 4434 J
Rome Formation(6)
Rome(6) 49.75(5) 83.35(5) 66.6(5)
Slug Bouwer-Rice 4.57E-04 1.30 NA NA 4435 J
Rome Formation(6)
Rome(6) 62.41(5) 79.9(5) 71.2(5)
Slug Bouwer-Rice 7.70E-04 2.18 NA NA 4436 J
Rome Formation(6)
Rome(6) 46.17(5) 65(5) 55.6(5)
Slug Bouwer-Rice 5.83E-05 0.17 NA NA 4437 J
Rome Formation(6)
Rome(6) 43.47(5) 63.77(5) 53.6(5)
Slug Bouwer-Rice 8.33E-04 2.36 NA NA GW-838 J
Rome Formation(6)
Rome(6) 19.12(5) 35.45(5) 27.3(5)
Slug Bouwer-Rice 7.58E-04 2.15 NA NA BRW-115(2)
K Not Specified Knox(6) 88.8 98.8 93.8 Slug Bouwer-Rice 1.08E-03 3.06 NA NA BRW-116(2)
K Not Specified Knox(6) 45 55 50.0 Slug Bouwer-Rice 3.73E-03 10.56 NA NA BRW-117(2)
K Not Specified Knox(6) 38.1 43.1 40.6 Slug Bouwer-Rice 2.35E-02 66.76 NA NA BRW-118(2)
K Rome Formation(6)
Rome(6) 45 65 55.0 Slug Bouwer-Rice 6.48E-05 0.18 NA NA UA-1 L
Not Specified Conasauga(6) 41.6 50.5 46.1 Slug Cooper 2.26E-05 0.064 0.57 NA UA-2 L
Not Specified Conasauga(6) 142 169 155.5 Slug Cooper 3.88E-09 0.00001 0.0003 NA UB-1 L
Dismal Gap Formation(6)
Conasauga(6) 25.9 35.5 30.7 Slug Cooper 1.48E-04 0.420 4
NA UB-2 L
Dismal Gap Formation(6)
Conasauga(6) 101 126.1 113.6 Slug Cooper 5.29E-07 0.002 0.037 NA UC-1 L
Rome Formation(6)
Rome(6) 77 86.2 81.6 Slug Cooper 9.17E-05 0.260 2.4 NA UC-2 L
Not Specified Chickamauga(6) 188.2 206.7 197.5 Slug Cooper 8.11E-06 0.023 0.42 NA UD-2 L
Pumpkin Valley Shale(6)
Conasauga(6) 180 205 192.5 Slug Cooper 3.32E-09 0.00001 0.00023 NA UE-1 L
Dismal Gap Formation(6)
Conasauga(6) 69.2 76.7 73.0 Slug Cooper 1.59E-04 0.450 3.4 NA UE-2 L
Dismal Gap Formation(6)
Conasauga(6) 175.7 197.7 186.7 Slug Cooper 3.88E-08 0.0001 0.0023 NA UF-1 L
Dismal Gap Formation(6)
Conasauga(6) 16.5 23.5 20.0 Slug Cooper 8.47E-04 2.400 17 NA UG-1 L
Nolichucky Shale(6)
Conasauga(6) 25 32 28.5 Slug Cooper 3.03E-04 0.860 6.1 NA UG-2 L
Dismal Gap Formation(6)
Conasauga(6) 242 300 271.0 Slug Cooper 1.73E-09 0.000005 0.00028 NA UG-3 L
Dismal Gap Formation(6)
Conasauga(6) 180 200 190.0 Slug Cooper 1.09E-06 0.003 0.063 NA UH-1 L
Nolichucky Shale(6)
Conasauga(6) 19 26 22.5 Slug Cooper 1.06E-04 0.30 2.1 NA UH-2 L
Nolichucky Shale(6)
Conasauga(6) 231 288 259.5 Slug Cooper 3.53E-09 0.00001 0.00059 NA
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-15 Revision 1 Table 2.3-A (Sheet 14 of 14)
A Selection of Oak Ridge Reservation Published Bedrock Aquifer Testing Results Well Data Source Geologic Unit Group Top Depth (ftbgs)
Bottom Depth (ftbgs)
Interval Midpoint (ftbgs)
Test Type Interpretation Method Hydraulic Cond.
Kavg cm/s Hydraulic Cond.
Kavg ft/d Trans-missivity(4) ft2/d Storage Coefficient(4)
UI-1 L
Nolichucky Shale(6)
Conasauga(6) 18 25 21.5 Slug Cooper 2.65E-04 0.75 5.2 NA UI-2 L
Nolichucky Shale(6)
Conasauga(6) 188 210 199.0 Slug Cooper 5.29E-08 0.0002 0.0034 NA HHMS1B L
Not Specified Conasauga(6) 182.3 201.2 191.8 Slug Cooper 2.01E-05 0.057 1.1 NA HHMS1C L
Not Specified Conasauga(6) 63.7 101 82.4 Slug Cooper 2.82E-05 0.08 3
NA HHMS2A L
Not Specified Conasauga(6) 380 400.6 390.3 Slug Cooper 1.38E-07 0.0004 0.008 NA HHMS2B L
Not Specified Conasauga(6) 180.6 200.6 190.6 Slug Cooper 2.29E-06 0.007 0.13 NA HHMS2C L
Not Specified Conasauga(6) 62.3 81.1 71.7 Slug Cooper 1.34E-05 0.038 0.72 NA HHMS3A L
Not Specified Conasauga(6) 380.5 399.1 389.8 Slug Cooper 1.90E-07 0.0005 0.01 NA HHMS3B L
Not Specified Conasauga(6) 189.7 211.6 200.7 Slug Cooper 2.36E-07 0.0007 0.0015 NA HHMS3C L
Not Specified Conasauga(6) 62 80.6 71.3 Slug Cooper 1.48E-05 0.042 0.78 NA HHMS4B L
Not Specified Conasauga(6) 174.3 215.3 194.8 Slug Cooper 1.13E-05 0.032 1.3 NA HHMS5B L
Not Specified Conasauga(6) 196.1 219.5 207.8 Slug Cooper 4.23E-06 0.012 0.29 NA HHMS5C L
Not Specified Conasauga(6) 42.1 63 52.6 Slug Cooper 5.64E-05 0.16 3.4 NA HHMS6B L
Not Specified Conasauga(6) 145 165.4 155.2 Slug Cooper 5.64E-06 0.016 0.32 NA HHMS6C L
Not Specified Conasauga(6) 40.8 60.8 50.8 Slug Cooper 4.59E-05 0.13 2.7 NA Notes:
NA = Not Available Maryville Limestone has been re-designated Dismal Gap Formation and Rutledge Limestone has been re-designated Friendship Formation (1)
Not included in analysis because depth information is missing (2) average of rising and falling tests or geometric mean of two interpretation methods (3) multiple zones screened (4)
Where multiple aquifer pumping test interpretations are available, the method results are reported (5)
Depths are relative to top of casing (6)
Geologic unit and/or group estimated based on available geologic information Sources:
A (Reference 2.3-A-1), Table F.10 B
(Reference 2.3-A-2)
C (Reference 2.3-A-3), Table D.1 D
(Reference 2.3-A-4), Table 14 E
(Reference 2.3-A-5), Tables 25 and 26 F
(Reference 2.3-A-6), Table 2 G
(Reference 2.3-A-7), Tables 4.2, 4.3, 4.4, 4.5, 8.1, 9.1, and 9.2 H
(Reference 2.3-A-8), Tables A.1 and A.2 I
(Reference 2.3-A-9), Table 4.2 J
(Reference 2.3-A-10)
K (Reference 2.3-A-11), Appendix B L
(Reference 2.3-A-12), Table 2 Repeated Test Results
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-16 Revision 1 REFERENCES Reference 2.3-A-1. Jacobs EM Team, "Feasibility Study for the Bear Creek Valley at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee," DOE/OR/02-1525/V2&D2, U.S. Department of Energy Office of Environmental Management under contract DE-AC05-93OR22028, November, 1997.
Reference 2.3-A-2. Webster, D. A. and Bradley, M. W., "Hydrology of the Melton Valley Radioactive-Waste Burial Grounds at Oak Ridge National Laboratory, Tennessee," Open-File Report 87-686, U.S. Geological Survey, 1988.
Reference 2.3-A-3. Bechtel Jacobs Company, LLC, "Field Summary Report for Drilling and Installation of the Melton Valley Offsite Monitoring Wells, September 2009 to August 2010,"
BJC/OR-3483, U.S. Department of Energy Office of Environmental Management under contract DE-AC05-98OR22700, September, 2010.
Reference 2.3-A-4. Rothschild, E. R., Huff, D. D., Haase, C. S., Clapp, R. B., Spalding, B. P.,
Farmer, C. D., and Farrow, N. D., "Geohydrologic Characterization of Proposed Solid Waste Storage Area (SWSA) 7," ORNL/TM-9314, U.S. Department of Energy Office of Defense Waste and Byproduct Management under contract DE-AC05-84OR21400, Oak Ridge National Laboratory, Environmental Sciences Division, December, 1984.
Reference 2.3-A-5. Moore, G. K., "Quantification of Ground-Water Flow in Fractured Rock, Oak Ridge, Tennessee," Ground Water Vol. 35(No. 3), 1997.
Reference 2.3-A-6. Moore, G. K. and Young, S. C., "Identification of Groundwater-Producing Fractures by Using an Electromagnetic Borehole Flowmeter in Monitoring Wells on the Oak Ridge Reservation, Oak Ridge, Tennessee," ORNL/ER-91, U.S. Department of Energy Office of Environmental Restoration and Waste Management under contract DE-AC05-840R21400, Oak Ridge National Laboratory Environmental Sciences Division, March, 1992.
Reference 2.3-A-7. Golder Assoicates, Inc., "Contaminant Transport Model Validation, Geohydrologic Site Characterization, and Groundwater Flow Computer Model Application,"
ORNL/Sub/88-SA706/5/V1, Oak Ridge National Laboratory for the U.S. Department of Energy under contract DE-AC05-84OR21400, September, 1988.
Reference 2.3-A-8. Science Applications International Corporation, "Decision Document for Performing a Long-Term Pumping Test at the S-3 Site, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee," Y/ER-210, U.S. Department of Energy Office of Environmental Restoration and Waste Management under contract DE-AC05-84OR21400, February, 1995.
Reference 2.3-A-9. Science Applications International Corporation, "East End VOC Plume Pump and Tracer Test Technical Memorandum," BJC/OR-103, U.S. Department of Energy Office of Environmental Management under contract DE-AC05-98OR22700, August, 1998.
Reference 2.3-A-10. Jacobs EM Team, "Task Order 125 - Documentation Regarding Slug Test Data and Analysis, White Wing Scrap Yard and East Bear Creek Valley Sites Task 35H83125,"
JE/OR/97-01839, Memorandum for Steve Lampkins, September 29, 1997.
Clinch River Nuclear Site Early Site Permit Application Part 3, Environmental Report 2.3-A-17 Revision 1 Reference 2.3-A-11. URS and CH2M Oak Ridge LLC, "Final Zone 1 Remedial Investigation and Feasibility Study for East Tennessee Technology Park, Oak Ridge, Tennessee," DOE/OR/01-2561&D1, U.S. Department of Energy Office of Environmental Management under contract DE-SC-0004645, March, 2012.
Reference 2.3-A-12. Tucci, P., "Hydrology of Melton Valley at Oak Ridge National Laboratory, Tennessee," U.S. Geological Survey, Water-Resources Investigations Report 92-4131, 1992.