Enclosure 2 to E-53386 TN-RAM SAR Revision 18 Changed Pages (Public Version)
E-10621 Rev. 18 TN-RAM SAR REVISION LOG E-10621 7
Rev. No.
Date Description 18 12/6/15 Revised pages as follows:
SAR cover sheet New pages as follows:
Revision Log page 7 Revised drawings as follows:
Drawing 990-708 New drawings as follows:
None 1/23/19 Revised pages as follows:
SAR page 2-18 New pages as follows:
Revision Log page 7 Revised drawings as follows:
Drawing 990-708 New drawings as follows:
None
Security Related and Proprietary Information on the Drawings in Section 1.3 are Withheld Pursuant to RIS 2005-31 and 10 CFR 2.390, respectively.
E-10621 Rev. 18 2-18 Table 2.3-3 SPECIFIED PROPERTIES OF IMPACT LIMITER WOOD CRUSH STRESS, psi WOOD TYPE DENSITY (1)
LB/FT3 MOISTURE CONTENT S0 PARALLEL TO GRAIN S90 PERPENDICULAR TO GRAIN(1)
LOCKING STRAIN Balsa 10-12 6-12 1560-2010 300-420 0.8 Redwood 18-27.5 6-12 5000-6500 750-975 0.6 Note 1: Typical values are provided for density and perpendicular crush stress (S90). These specifications are not important to the performance of the packaging.