'I orano Federal Way Office USA so~ s. 335th Street Suite 400 Federal Way, WA 98003 Tel: (253) 552-1310
@orano_USA January 14, 2019 FS-19-0003 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
- 2) Letter from Norma Garcia-Santos to Philip Noss of December 21, 2018, transmitting a Request for Supplemental Information (RSI)
Dear Ms. Garcia-Santos:
Otano Federal Services LLC (Orano FS) hereby submits a response to the RSI referenced above. RSI-l(a) requests a H~ting of the documents constituting the licensing basis for the 1105-SD package. Attachment A gives the. requested information for the six calculations and two ce1tification test documents that forms the safety basis for the435-B package, and wl;iich apply fully to the 1105-SD pacl~age. AH appl.icable computer analysis files are associated with specific calculation documents, and consequently are not separately listed. All calculations; reports, and computer files al'e available in Orano's Records Management system. There are no ADAMS accession numbers associated with these documents.
RSI-J (b) requests a description of the quality assurance program.applicable to the 1105-SD package. The safety basis. for the 1105-SD package was developed u.nder Orano's NRC-approved 10 CFR 71, Subpart H quality assurance program.
The NRC Quality Assutance Program Approval number is 0938, granted to Orano Federal Services LLC Quality Assurance Program document No. FS-QA-PMD-001.
The following observation was als0 jncluded in the ref~renced document:
OJ:3$-Co-1 Provide the following descriptions in the Model No. 1105-SD safety analysis report (SA.R):
- a.
- b.
Page 1 of6
$tan.dards used to.certify personnel that develops and approves written leakage rate testing procedures; qualifications of personnel that develops and approves written leakag~ r~te testing procedures;
,orano Federal Way O(flte USA 505 S. 336111 Street
.Suit~ 400 Federal Way, WA 98003 Tel: (253} 552-1310
@orario_USA
. I
- c.
January 14, 2019 FS-19---0003
. standards us~d to certify personnel that performs leakage
' rate testing; and cf.
qualifjcatiQns of per$<>nnel thc;1t performs leakage rate testing.
'1 Sections 7.4, 8.1.4, and 8.2.2 of the Model No. 1105-SD applrc~tion includes a clesqriptjon of leakage rate t~ting procedures. In these sections, the staff noted that the applicant does not mention the following regarding nondestructive testing (NDT} 'personnel:
- 1.
if only personnei certified as an ASNT Level Ill examiner for leakage testing shall deveiop and approve written leaka9e rate testing procedures, and;
- 2.
if personnel performing leakage rate testing shall be qualified and certified in accordance with Recommended Practice No. SNT-TC-1A, "Personnel Qualification and Certification in Nondestructive Testing."
Please specify whether the written leakage rate testing procedures are cfev~loped, approved, and performec! by qualified and certified NDT personnel.for leakage testing in accordance with industry standards to ensure thatthe package is designed, constructed, and prepared for shipment to comply with the requirements in 10 CFR Part 71.
In 1*esponse, Or:an9 note~ that both Ch~pter 7 ~ml Cb~pter 8 of the 1 l Q5-SD SAR reference ANSI Nl4.5-2014, Leakage Tests on Pa<;kages for $hip1J1ent.
Section *8.8 of this standard states in prut:
. Leakage rote testing procedures shallbe approved'by_personnel whose qualification and certification 'in the nondestructive method of leak testing inc/i;Id~s certifjc~tion /;Jy a -mifionalfy. recognize(! socj~ty a.t a l,evf)J appropriate to.the writing and/or review of leakage rate testing procedures.
The phrase "... ce1tification by a nationally recognized society.*. " implies certification to the standards of the American Society for Nondestructive Testing (ASNT), which is the *only applfoable nationally rec9gnized society in this country. Similarly,'"..* at a level ~pptopriate to the writing and/or review of leakage rate testing procedures" implies certification to Level HI. Thus; the requirement in the SAR to follow ANSI N14.5-2014 includes the*requi1:e1nent that leakage rate,testing procedur~s must be approved by personnel ce1tifo:d by ASNT as a Level III test technician.
.
- Similarly, Section 8.8 of ANSI N14.5 - 2014 states in part:
Page 2 of 6
orano Federal Way PfficeUSA 505 s. 3361h Street Suite 400 Federal Way, wA 98003 Tel: {25j) 552-1310
@orano_USA I
I Jan~uary 14, 2019 FS-19-000~
li:.eal<fJge r~te testing shall be performed by personnel tl]at are qµal/fied and.certified in accordance with the requirements bf [Reference 5), in Section 9:
I I
Reference 5 of'\\ANSIN14.5 is ASNTRecommended Practice No. SNT.. Tc-;1A.
Thus, the -tequfrement in the SAR to follow ANSI N14.5 -2014 includes the requirement that leakage rate testing must be performed by personnel qualified and certified in accordance with ASNT SNT-TG-lA.
In summary, the answer to questions #1 and #2 above is~ written leakage rate testing ptocedµre~ for the 1105-SD pac~ge ate developed, a:ppt'oved, and performed by qualified arid ce1tified NDT personnel for leakage testipg in accordance with industry sta_nda1*ds. For these reasons, OranQ believes 110 fmther detail, other than ref¢rence to ANSI NI4.5 -2014, is necessary in the text of the*
SAR.
Orano also notes that all text relating to leakage rate testing in the 1 i 05-SD SAR is idel)tical to the text "in Revis_i<:>n 4.3 ofthe 435-B SAR except that the edition
.of ANSI Nl4.5 is updated to the 1atest 2014 edition. Revision 5 of the 435-B SAR, cun-ently underNRC review, also references the 2014 edition.
Shouid you have any questions regardin$ this submittal, please contact me at (233) 552-1321 or via email (phil.noss@orano.group ).
Yours Tru~y,
. /f)all YWV' Philip Noss Licensing Manager Otano Fedel'al Setvices LLC O~pieS:
Attentfoni Norm~ Garc.ia-Sautos, ProjeGt Manager U.S. Nqcle.atRegula:tqry Gomrnfasiqn 11.545 Rockville Pile~
Rockviile, MD 20852 Richard J. Smith, Project Manager, Orano Fed~ral Services LLC Attachment A, Tabie ofLicensin~ Basis Documents A}'.>pficable to the 1105-S.b
orano Discipline Structural (Free*Drop).
Page4 of 6.
Attachment A J~n'wary 14, 2019 FS-19-0003 Table of Licensing Basis Documents Applicable to the 1105-SD Docket 71-9379, L-2018-NEW-0002 Document Number Documentum Title Revision Date Description
- Number No.
01916.01.C004.0I.:07 cALC~3oo69n-ooo 435-B Drop Analysis 0
5/14/12 This calculation fonns the pasis of SAR Section 2.12.4. The objective of this calculation is to demonstrate the 435-B certification test orientations i:lfe the worst-
.cases and appropriate. for the licensing basis. The primary method this will be demonstrated is by comparison of the package free drop accelerations between the simulations and certification testing. The certification test orientations must be the worst case and conservatively demonstrate the structural Nonna! Conditions of Transport (NCT)and Hypothetical Accident Condition (HAC) free drop.safety effectiveness* of the package. If a particular packaging attribute or result cannot be confirmed by the certification testing, then the simulation rei;ults in this calculation may be utilized to demonstrate additional package safety for the license application.
This analysis includes computer files.
Discipline Document Number Docl!mentum Title Number Structural 01916.0I.C004.01-0 t CALC-3003541-000 435-B Weight (Weight)
Calculation Structural 01916.0I.C004.01-02 CALC-3003967-000 Buckling Analysis (Buckling) forLANL-B Transport Package (LANL-B later became known as the 435-S:)
Thermal 01916.0l.C004.0l-08 CALC-3007066-005 Thennal and Gas Generation Analysis for the-435-B Package Pages of6 Revision Date No.
0 3/1/12 0
2/7/11 5
1/25/17 Description January14, 2019 FS-19-0003 This calculation forms a partial basis for SAR: Chapter 2. This calculation finds the weight, position ofthe center ofgravityand the mass moment of inertia of the 435-B transport package loaded with the lodgment
/longterm storage shield and the inner container/ shielded devlce for both the certification test unit and the production unit. This analysis irtcludes computer files.
This calculation forms a partial basis for SAR Chapter 2. This *calculation evaluates the LANL-B transport package for buckling from HAC immersion case required by 10 CFR §7L73(c)(6). This calculation shows that the design is adequate to support the applied loads. This analysis includes computei: files.
This calculation forms the basis of SAR Chapter 3. This calculation determines the thermal and gas.generation.safety basis for the 435-B transport package used to transport radioactive sealed sources in the Long Term Storage Shield (LTSS) or shielded devices containing their sources.
This analysis includes computer files.
orano Discipline Document Number Documentum Title Number Shielding O l 916.0l.C004.01-05 CALC-3006640-001 LANL-B Device Shielding Analysis (LANL-B later became known as the 435-B.)
Shielding Ol 916.0l.C004.01-06 CALC-3006972-001 435-B LTSS Shielding Analysis Certification PKG-TP-SPC-008 SPC-3004633'-002 435-B Package Test Certification Test Procedure Certification PKG-TR-SPC-011 SPC-3006329-001 435-B Package Test Certification*test Report Page 6 ofG Revision Date No.
I 4/11/12 1
9/10/15 2
11/2/11 1
4/17/12 Description January 14, 2019 FS-19-0003 This calculation fonns the basis of SAR Section 5:5.3. This calculation presents the shielding analysis for the 435-B cask when transporting irradiation devices. The calculated dose rates are below the non-exclusive use regulatory limits. This analysis includes computer files.
This calculation fonns the basis of SAR Chapter 5. This calculation presents the shielding analysis for the.435-B cask when transporting anL TSS. A number of different source isotopes are examined to determine the maximum allowable activity level based on dose rate and decay heat limits. The calculated dose rates are below the regulatory limits. This analysis includes computer files.
This document defines the requirements for the certification tests to be performed on the 435-B package with a LontfTerm Storage Shield (L TSS) and Shielded Device Payload.
This document fo1ms the basis for SAR Section 2.12.3. This document contains the results and data from the certification tests of the 435-B package, which occurred during November and December 2011.