Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5014862 Page 1 of 2 January 11, 2019 Mr. Michael C. Layton, Director Via Regular Mail & Email Division of Spent Fuel Management Michael.Layton@nrc.gov Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738

Subject:

Supporting Documents from Holtec International PEC Meeting Ref: 1:

USNRC INSPECTION REPORT 07201014/2018-201 NRC Docket # 72-1014

Dear Mr. Layton:

As discussed in the Pre-decisional Enforcement Conference (PEC) on the apparent violations in the NRCs Inspection Report [Ref 1], Holtec is pleased to submit some supplemental information to the NRC staff. Attached to this letter is an updated version of the presentation given at the PEC meeting, with some minor edits and clarification to ensure a complete and accurate record.

Also attached to this letter is a memo summarizing the issue, which was shared with Holtecs stakeholders, and may be useful to the NRC staff. Both of these attachments do not contain proprietary information and may be shared publicly. Holtec will submit any proprietary supporting documents under separate cover letter.

If you have any questions, please contact me at (856) 797-0900 ext 3951 Sincerely, Kimberly Manzione Licensing Manager Holtec International Attachments: : Holtecs Input to the PEC Proceedings on NRCs Inspection Report Presentation by Dr. Kris Singh : Summary Briefing to Holtecs Stakeholders on the January 9, 2019 NRC PEC Meeting dated January 6, 2019