consumers Power company

  • .,,--.**. *.-**,,,........,:,'r. i'.

I

~

j General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201

  • Area Code 517 788-0550 June 15, 1978 Mr James G Keppler Office of Inspection and Enforcement Region III US Nuclear Regulatory Coimllission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

CYCLE 3 START-UP PHYSICS TESTS

,~~-c* ll (' r-",.....- 7 1

-' I /j' 1 __

I

(_,,'._._!

LJJ

-..(}

CJ

-J Cf.)

CJ) c::_

-*I

?::

c-..:

z:

r.r:i r-;:;*--~-

~)

=!Cl 0

>o-....

-P-.-'1-.-..,....

n

-0

i:cr, 0

~~

rri

u 0 rri C1'1 en I~

[-:,

c*:*

C:" ~ ~-~

r*1.c:.

._
p;

<c.:i C!CJ 1-l(i;

(/')_j c:-r;i

i::Cj
.:jc:

--l C)

The attached report entitled, "Palisades Core -

3 Low Power and Power Escala-tion Test Report," June 1978 is submitted per the requirements of Palisades Plant Technical Specification 6.9.1.a.

This report meets the requirements of the January 17, 1978 NRC letter that requested a summary report of physics start-up tests.

David P Hoffman (Signed)

David P Hoffman Assistant Nuclear Licensing Administrator CC:

Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement.

/!=~ 1 72(115(1