ML18353B229

From kanterella
Jump to navigation Jump to search
Cancellation of Abnormal Occurrence Report 75-08 Re High Cooling Water Discharge Temperatures Were Due to Error in Temperature Measuring Technique
ML18353B229
Person / Time
Site: Palisades 
Issue date: 04/17/1975
From: Sewell R
Consumers Power Co
To:
Office of Nuclear Reactor Regulation
References
LER 1975-008-00
Download: ML18353B229 (1)


Text

'

l

,,.. *~

Division of Reactor Licensing \\ *

\\

US Nuclear Regulatory Commission Washington, DC 20555 Gentlemen:

consumers Power April 17, 1975 Re:

Docket 50-255 License DPR-20 Palisades Plant A0-75-8 On April 7, 1975 you were notified of an occurrence involving Palisades Plant cooling water discharge temperatures which were thought to be higher than the allowable limit. The occurrence was designated A0-75-8~

A review of our temperature measuring technique has disclosed the temperature measurements to be in error.

The revised measurements show the discharge temperatures to be within the allowable discharge limit.

A0-75-8, therefore, has been canceled.

Yours very truly,,

/J ~4'\\1

/J

/cµ_rV'-~.'~~~7?/

DAB/mel Ralph B. Sewell Nuclear Licensing Administrator CC:

JGKeppler, USNRC