consumers Power company R.EGUlATO~Y r~CKET ALE COPY:

General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201

  • Area Code 517 788-0550 March 1, 1978 Director, Nuclear Reactor Regulation Att:

Mr Denriis L Ziemann, Chief Operating Reactor Branch No 2 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

STEAM GENERATOR INSPECTION REPORT The attached report entitled, "Report of Eddy Current Testing Data Evaluation and Tube Repairing," dated February 1978, describes the results of' the Palisades Plant steam generator inspection which took place between January 15 and February 12, 1978.

The information in this report supports our request of February 21, 1978 for changes to the Palisades Plant Technical Specifications relating to steam gen-erator operating allowances and inspection requirements.

The operating allow-ances proposed in the February 21, 1978 request have been modified to comply with NRC staff recommendations and the appropriate Technical Specification page is provided as Attachment 1.

fffiw}fJ~.

I David P Hoffman Assistant Nuclear Licensing Administrator CC:

JGKeppler, USNRC