e.

E)${0N ~UCLEAR COMPANY, Inc.

2101 Horn'1fapids.'Road, Richland, Washington 99352.

PHONE: (509) 946-9621 Director of Nuclear Re.actor Regulation Attention:

R. A. Purple, Chief Operating Reactor Branch No. 1 U. S. Nuclear Regulatory Commission Washington, D.C.

20S5S.

April 16,

  • 1976

Reference:

Docket No. 50-255 License No. DPR-20 Palisades Plant

Dear Mr. Purple:

The enclosed information is.submitted directiy at the request of Mr. R. B.

Sewell of Consumers Power.

This information is provided in response to your question. regarding the extent of metal-water reaction as part of the.,

ECCS analysis for Type D fuel.

~-

GFO: lp Enclosure Sincerely,

}

. *11~

~

j I

~

.. Owsley, Reload Licensin AN AFFILIATE OF EXXON CORPORATION 4082

~-Lo...

-~*-

~-.

.-./

s EXTENT OF LOCAL MAXIMUM METAL.
WATE.R 'REACTION PALISADES CYCLE 2 ECCS ANALYSIS The value reported for 11 D'.

1 fuel Loop 2 *break (XN-:76-4, Supplement 1, p~ge 6) is 11 less* than 13 percent.

11 The value reported for 110 11 fuel*toop*.l break cleanup calculation was 11 less than 17 percent.

11 These* two numbers ~ere.£onservatively ~stimated in order to expedite th~*documentation'of the EC~S a~alysis.

This was possible at that time as the ~xtent of metal-water reaction was clearly less.than the Appendi~ K limit.

A refined estimate of metal-water reaction shows the ~xt~nt to be* less than the cited ]3and*17 percent.

The refined estimates.for the Loop 2 and Loop l breaks are r~specti ve ly b.etween 8 - 9.percent and be.tween 9 - l 0 percent, the latter correspondi n*g. to the s ii ghtly higher PCT case.

it should be noted that the peak metal-wate~ reaction node is the ruptured no~e and not the PCT ~ode.

Th~ extent of.the ~etal-water reaction in all other nodes is significantly less than that of the rupture node.