ML18344A072

From kanterella
Jump to navigation Jump to search
Global Nuclear Fuel-Americas, LLC - U.S. Nuclear Regulatory Commission Inspection Report 70-1113/2018-401
ML18344A072
Person / Time
Site: 07001113
Issue date: 12/07/2018
From: Nease R
NRC/RGN-II
To: Beard B
Global Nuclear Fuel
References
IR 2018401
Download: ML18344A072 (3)


Text

OFFICAL USE ONLY - SECURITY-RELATED INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 OFFICAL USE ONLY - SECURITY-RELATED INFORMATION December 7, 2018 Mr. Brad Beard Facility Manager Global Nuclear Fuel - Americas, L.L.C.

P.O. Box 780, Mail Code J20 Wilmington, NC 28402

SUBJECT:

GLOBAL NUCLEAR FUEL - AMERICAS, L.L.C. - U.S. NUCLEAR REGULATORY COMMISSION INSPECTION REPORT 70-1113/2018-401

Dear Mr. Beard:

This refers to the inspection conducted from November 5 - 8, 2018, at the Global Nuclear Fuel -

Americas, L.L.C. (GNF-A) Wilmington, North Carolina facility. The purpose of this inspection was to determine whether activities authorized by the license were conducted safely and in accordance with NRC requirements. The enclosed report presents the results of the inspection that were discussed with members of your staff during an exit meeting held at the end of the inspection on November 8, 2018.

This inspection examined activities conducted under your license as they relate to public health and safety, the common defense and security, and to confirm compliance with the Commissions rules, regulations, and the conditions of your license. Areas examined during this inspection included management structure, item control, measurement systems and control, physical inventory, resolution, assessment, and recordkeeping. Within these areas, the inspection consisted of performance tests, selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress.

There were no violations of more than minor significance identified.

The enclosed inspection report contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosures will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

The enclosure contains Sensitive Unclassified Non Safeguards Information (Security-Related Information). Upon separation, this cover letter is DECONTROLLED.

OFFICAL USE ONLY - SECURITY-RELATED INFORMATION B. Beard 2

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public inspections, exemptions, requests for withholding, of the NRC's "Agency Rules of Practice and Procedure," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room, or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS); accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this report, please contact Manuel Crespo at 404-997-4733, or via e-mail to manuel.crespo@nrc.gov.

Sincerely,

/RA/

Rebecca Nease, Chief Safety Branch Division of Fuel Facility Inspection Docket No. 70-1113 License No. SNM-1097

Enclosure:

NRC Inspection Report 70-1113/2017-401 w /

Attachment:

Supplemental Information cc:

Scott Murray, Manager Facility Licensing Global Nuclear Fuels - Americas, L.L.C.

Electronic Mail Distribution W. Lee Cox, III, Chief North Carolina Department of Health and Human Services Division of Health Service Regulation Radiation Protection Section Electronic Mail Distribution

ML18344A072 SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DFFI SIGNATURE

/RA/

NAME RNease DATE 12/7/2018 E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO