ML18338A172

From kanterella
Jump to navigation Jump to search
IP 71111.22 Assessment 36
ML18338A172
Person / Time
Issue date: 04/24/2019
From: Aron Lewin
NRC/NRR/DIRS/IRIB
To:
Lewin A, 415-2259, NRR/DIRS
References
Download: ML18338A172 (3)


Text

Inspection Procedure Assessment Summary and Outline of Proposed Changes Inspection Procedure (IP): IP 71111.22, Surveillance Testing Inspector Procedure Lead: Chris Cauffman Estimated Hours to Complete Review: 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Date Review Completed: 9/11/18

1. Results and assessment of review of IMC 0308, ROP basis document review Complete
2. Results and assessment of review of any applicable changes to PIs A three year review by the PI lead did not identify any significant changes to PIs that would result in a reduction or unintended gap in the key safety attributes of each safety cornerstone.
3. Results and assessment of review of any applicable changes to Rules and STSs Revisions to rules and Standard Technical Specifications within the last three years did not indicate a need for revision beyond those already captured in feedback.
4. Results and assessment of review of recent Operating Experience None Noted
5. Results and assessment of review based on RRPS data (see separate IP [list IP number]

Assessment Data file for details of RRPS data)

Adverse trends or outliers noted: No

No greater than green findings or greater than Severity Level IV violations. Very noticeable downward trend in findings.

19.3(4.6)=~89hrs Budget 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> Other Issues:

05000364 Farley 2 2017002 disposition as NCV under NCV 2017003-001 (2 records for same issue) 05000391 Watts Bar 2 2016002-05 No color for finding

6. Feedback Forms 71111.22-2067 Aging Management 71111.22-2147 Leakage Monitoring 71111.22-2276 FLEX equipment 71111.22-2329 vertical slice guidance consolidation 71111.22A-1857 Risk Management TS Initiative 5b Surveillance Frequency Control Program (SFCP)

Recently closed feedback forms:

ML15280A363 71111.22-1963 Ensuring correct test requirements

7. Other Considerations None.
8. Results of discussions with regions

Region 1 thru 3 did not participate G. George Recommendations Address open feedback forms during next revision.